Karnataka State Seeds Corporation Limited Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Karnataka State Seeds Corporation Limited - KSSCL Tender

Opening Date15 Jan 2021
Closing Date27 Jan 2021
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Cutting of road surface for pipeline trenches and disposing of the excavated stuff as directed including barricading, danger lighting etc. in the following classification Cutting Asphalt Road Surface

33.41

-

19919.04

... More
Providing and laying in position plain cement concrete of grade M 15 with cement @ 240kgs, with 20mm and down size graded granite metal coarse aggregates @0.878cum and fine aggregtes @ 0.53cum, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation,plinth and cills, ncluding cost of all materials, labour, HOM of machinery, curing complete as per specifications..( RWS SR , I no.4.04)

7.43

-

48220.7

... More
Supplying HDPE pipes conforming to IS 4984:1995 with latest amendments and conveying to work site including loading and unloading at both destination and rolling, lowering into trenches, laying true to line and jointing of pipes and specials by electrofusion welding, as per standerd procedure and guide lines including encasing the pipe around to a depth not less than 15cms with cleaned soft gravel or selected earth available from the excavation etc., complete giving hydraulic test as per relevant IS Specification with all lead and lift including , testing and commissioning. The rate is exclusive of required specials and fittings etc., complete (Contractor will make his own arrangement for procuring water for testing)Upto 90 mm dia 6ksc ,Coils shall be used.

3500

-

889350

... More
Refilling the basement and pipeline trenches with selected available earth from trench excavation including watering, Consolidation in layers of 15 cm thick including disposing of the surplus earth with all lead & lifts. ( RWS SR , I no.2.25)

8859.38

-

1003767.75

... More
Providing, supplying to work site, fixing of Submersible PumpSet of 150mm dia suitable for bore well and confirming to IS 8034 3Phase, SS Bowl & Impeller with Low volt Motor and as per specifications, with testing, as per instructions of engineer incharge of work and latest amendmnents 10.00 HP - 360 LPM @ 75 m = 5 STG Outlet Dia - 3.00"

3

-

133701

... More
Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments.1X3X4 Sqm (PHE SR Item no1112.03.c P.No.104)

90

-

9720

... More
Supply installing testing and commissioning COMMON CONTROL PANEL consisting of the following INCOMING 1 No. Set of Phase indicating lamps with SFU of suitable 1 No., Analog Ammeter, 1 No Analog Voltmeter 1 No. with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump 1 No. MCB 1No. DOL of S/D Starter suitable for respective HP 1 No. Electrical Protection like single Phase preventor, Under voltage Over voltage, Under current Over current Protection suitable for the pump described above 1No. OUTDOOR type Up to 6HP. (RWS SR I.no.12.08.a P.no.105)

1

-

9517

... More
Supplying HDPE pipes conforming to IS 4984:1995 with latest amendments and conveying to work site including loading and unloading at both destination and rolling, lowering into trenches, laying true to line and jointing of pipes and specials by electrofusion welding, as per standerd procedure and guide lines including encasing the pipe around to a depth not less than 15cms with cleaned soft gravel or selected earth available from the excavation etc., complete giving hydraulic test as per relevant IS Specification with all lead and lift including , testing and commissioning. The rate is exclusive of required specials and fittings etc., complete (Contractor will make his own arrangement for procuring water for testing)Upto 110mm dia,Coils shall be used.(RWS SR I.No.10.20.1(B))75 mm Dia PN 6

30

-

5907

... More
Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments (RWS SR I.no.12.06.b P.no.79) 80mm dia

3

-

5197.5

... More
Supply and delivery at site wrought middle steel (galvanized) 65 mm dia GI union confirming to IS 1239-II, 1991 with latest amendments if any. (PHE SR.I.N.15.78.6.n.212 , )

3

-

735

... More
Providing wrought mild steel (galvanized) 65 mm dia GI collar confirming to IS 1239-II, 1991 with latest amendments if any. (PHE SR.I.N.15.72.6.n.211 , )

3

-

615

... More
Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work (PHE SR Item no.12.16, P.No.105)

3

-

16950

... More
Labour charges for Erection of outdoor type panel board and meter board units with all necessary materials and labour tools and equipments including providing cement concrete foundation bed etc., complete. as per specifications, with testing of as per instructions of engineer incharge of work (PHE SR Item no.12.18, P.No.106)

3

-

3594

... More
Open condute system. Supplying heavy gauge PVC conduit pipe 19/20mm dia confirming to IS 2509 with suitable size bends junction boxes adhesive paste etc,and fixing using inverted wood plugs in case of RCC ceiling and RCC walls stone structure or raw plugs in case of brick walls and cement plastering to damaged portion using heavy gauge saddles at an interval of 700 mm using WF screws. 19/20mm dia 2 mm thick (Electrical SR)

3

-

162

... More
Point wiring using copper wire with switch. Suoplying and wiring adopting loop system in existing PVC Conduit / casing capping using copper PVC insulated multi strand 2x1.5 Sqmm copper wire with 6 Amps flash type SP control switch shall be fixed on the existing plastic sheet/gang box the other end of the wires shallerminated with sufficient loose length in a wood/PVC/round block complete for each out let. Short ppint up to 3m from tapping point to out let via switch. (Electrical SR)

3

-

522

... More
Supplying and fixing PBBC brass/bakelite straight or shant batten holder and wiring with in 60 W/230 V. lamp.(Electrical SR)

1

-

88

... More
Supplying and fixing 32 Amps flush/project typ Bakelite D.P. with neon indicator over existing wood board or flash mounting in plastic plates/inches (Electrical SR)

1

-

150

... More
Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit confirming to IS 3049/1968. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. (Item 12.23 Page No. 104 RWS SR)

2

-

7992.6

... More
Supplying and fixing one of 32A. Porciline Fuse channels with cutouts on existing wooden/panel board using necessary nuts bolts and washers etc, complete. (Electrical SR)

3

-

540

... More
Supplying of TPST 32 amps with rewirable porcelain channels in SM enclosure. (Electrical SR)

1

-

1865

... More
Fixing of 25 to 63A.TPST /change over switch along with neutral link with xrews bolts, nuts andf wiringusing required capacity wires and circuit labelling.a) 15A to 63A TPST (Electrical SR)

1

-

238

... More
Supplying fixing and wiring current operated earth /residual current circuit breaker 240/450 V with 6 kA short circuit withstanding capacity upto 100-300 mA sensitivity on existing wood/panel board 40 Amps 4 Pole. (Electrical SR)

1

-

2500

... More
Supplying and fixing of LED type panel Board indicating lamp with required color suitable for 220 v A.C.50 Hz 12/24 v DC Group B (Electrical SR)

1

-

442

... More
Insulated cable on messenger wire using 2 single corewires for a single phase and 4 single core wires for 3 phase. Supplying and stringing PVC insulated and PVC sheathed 650/1100V class aluminium cunductor of siz supported by 3.15 mm. (10 SWG) GI mesenger wire with two break insulators, one at each end of the span with suspenders at intervals iof 0.75 m. Each suspender shall be porcelain reel insulators, of suitable core through which insulator wire passes(single core or twin core a the case may be) and this reel insulator shall be fixed to the messenger wire using 2 mm (No.14SWG) GI witre suitably blent and twisted. Seperate reel insulator shall be provided for each wire, the mesenger wire shall be dead-ended on the clamp provided to the departmental pole wide item no:4 above 3 Phase using 4 wire. 10 Sqmm page 65/ 5(d) (Basic Rate 125.00 + 5% Area Wt)

15

-

1875

... More
Supplying and fixing guy set for items I (a) and (b) (Wherever span exceeds 10mm) formed out of not less than 12mm dia with cement concreting work including one break insulator as per approved drawing. If a suitable wall or RCC roof is not available for anchoring guy sets the anchoring has to be done by fixing GI wire to the rafter of the tile or absetors. (Electrical SR)

1

-

175

... More
Supplying, fixing and wiring service mains in pipe of the following sizes with necessary threaded water tight bend, collers, hooks, wooden plug, bushing and screws etc.A. 16 SWH braised conduit pipe finished with black stove enamelling inside and outside.B. PVC conduit pipe.C. PVC insulated Aluminium wire 650/1100V grade.Single core or twin core as the case may be) with necessary length of loose wire not less than 1 meter long to be terminated inside meter board without joints and connected to the main side of the energy meter, using be- metallic connectors, accessories, sleevs etc inclusive of masonry path work. The conduit shall be connected ot the earth electrode by means of GI wire not less than 4mm (8SWG) and tinned clamp of width 25mm and 24 guage with GI bolt, nut and washers. Three Phrase service mains with 4 wire. 4 x 10 sq.mm. in 32 mm conduit. (Electrical SR)

3

-

540

... More
Supplying and fixing 500 x 500 x 65 mm. (20" x 20" x 2.5") polished wood board made of not less than 15 mm. Thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs, screws, etc. (Electrical SR)

1

-

302

... More
Supplying, fixing and wiring electronic 5 to 40 Amps three phase 4 wire Energy meter Group B (Electrical SR)

1

-

3425

... More
Supplying,transportation and errection of Concood cement concrete box type pump house of size 132cmsx56cmsx28cms with two support of size 30cmx 4cmx 153cms made of fabricated steel structure of 4mm MS wires welded together coupled with chicken mesh and provided with edge stiffeners in the form of MS Flats of size 20mmx3mm with 6mm aggregates,having thin (less than 1 inch )sections in general and all surfaces are painted with two coats of anti-fungus paint of approved appropriate colour and shade including excavation embedding into cement concrete of mix M20 proportion of size 60cmsx30cmsx45cms ,and refilling the excavated stuff with all lead and lift etc complite (PHE Page No 106 Miscellaneous)

1

-

11640

... More
Earthwork excavation by manual means for foundation of buildings, culverts, water supply and sanitary lines and electrical conduits etc, either in pits or in trenches 1.5m and above in width, in hard soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. including breaking of clods complete as per specifications(PHESRI No: 2.05 P.No.24)

18.5

-

9116.8

... More
Providing and laying in position plain cement concrete of grade M 10 with OPC cement @ 220kgs, with 40mm and down size graded granite metal coarse aggregates @0.892cum and fine aggregtes @ 0.465cum machine mixed, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation including cost of all materials, labour, HOM of machinery, curing complete as per specifications. SpecificationPHESRI No 4.42 P.No.33

1.35

-

8336.79

... More
Providing and laying Reinforced cement concrete of mix design of M-25 Grade with cement @ 340 kg, 20mm and graded granite or trap or basalt jelly of approved quality @ 0.7 cum and fine aggregates @ 0.47 cum, super plasticiser @ 3lts confirming to IS-9103-1999 reaffirmed 2008 in layers of not more than 15 cms thick, well consolidated including centering, formwork, vibrating, curing, smooth finishing to the required plumb and face in C.M.1:3 proportion wherever necessary etc., complete for R. rafts, raft ring-beam, column footing, columns below ground level (exclusive cost of steel and fabrication charges)(PHESR P No 39 I No 4.43)

3.33

-

25139.17

... More
Providing and laying Reinforced cement concrete of mix design of M-25 Grade with cement @ 340 kg, 20mm and graded granite or trap or basalt jelly of approved quality @ 0.7 cum and fine aggregates @ 0.47 cum, super plasticiser @ 3lts confirming to IS-9103-1999 reaffirmed 2008 in layers of not more than 15 cms thick, well consolidated including centering, formwork, vibrating, curing, smooth finishing to the required plumb and face in C.M.1:3 proportion wherever necessary etc.,complete as per design and specification for staging, columns and braces above ground level (exclusive of cost of steel and fabrication charges)(staging 9.00m height.PHESR P No 39 I No 4.47.1)Upto 6.00m ht

1.5

-

17556

... More
Providing and laying Reinforced cement concrete of mix design of M-25 Grade with cement @ 340 kg, 20mm and graded granite or trap or basalt jelly of approved quality @ 0.7 cum and fine aggregates @ 0.47 cum, super plasticiser @ 3lts confirming to IS-9103-1999 reaffirmed 2008 in layers of not more than 15 cms thick, well consolidated including centering, formwork, vibrating, curing, smooth finishing to the required plumb and face in C.M.1:3 proportion wherever necessary etc.,complete as per design and specification for staging, columns and braces above ground level (exclusive of cost of steel and fabrication charges)(staging 9.00m height.PHESR P No 39 I No 4.47.1 6.00 to7.50m ht

0.38

-

4561.63

... More
Providing and laying Reinforced cement concrete of mix design of M-25 Grade with cement @ 340 kg, 20mm and graded granite or trap or basalt jelly of approved quality @ 0.7 cum and fine aggregates @ 0.47 cum, super plasticiser @ 3lts confirming to IS-9103-1999 reaffirmed 2008 in layers of not more than 15 cms thick, well consolidated including centering, formwork, vibrating, curing, smooth finishing to the required plumb and face in C.M.1:3 proportion wherever necessary etc.,complete as per design and specification for staging, columns and braces above ground level (exclusive of cost of steel and fabrication charges)(staging 9.00m height.PHESR P No 39 I No 4.47. 1 7.50mto 9.00m

1.88

-

23147.12

... More
Providing and laying Reinforced cement concrete of mix design of M-25 Grade with cement @ 340 kg, 20mm and graded granite or trap or basalt jelly of approved quality @ 0.7 cum and fine aggregates @ 0.47 cum, super plasticiser @ 3lts confirming to IS-9103-1999 reaffirmed 2008 in layers of not more than 15 cms thick, well consolidated including centering, formwork, vibrating, curing, smooth finishing to the required plumb and face in C.M.1:3 proportion wherever necessary etc.,complete as per design and specification for staging, columns and braces above ground level (exclusive of cost of steel and fabrication charges)(staging 9.00m height.PHESR P No 39 I No 4.47. 9.00 to10.50m ht

1.12

-

14143.36

... More
Providing and laying Reinforced cement concrete of mix design of M-25 Grade with cement @ 340 kg, 20mm and graded granite or trap or basalt jelly of approved quality @ 0.7 cum and fine aggregates @ 0.47 cum, super plasticiser @ 3lts confirming to IS-9103-1999 reaffirmed 2008 in layers of not more than 15 cms thick, well consolidated including centering, formwork, vibrating, curing, smooth finishing to the required plumb and face in C.M.1:3 proportion wherever necessary etc., complete as per design and specification and giving satisfactory water proof test including construction joints wherever necessary as per the directions of the departmental Officers complete for ring beam, side walls, bottom dome or bottom slab, shell portion and bottom ribs (exclusive of cost of steel and fabrication charges and jointing materials)

9.29

-

175102.56

... More
Providing and laying Reinforced cement concrete of mix design of M-25 Grade with cement @ 340 kg, 20mm and graded granite or trap or basalt jelly of approved quality @ 0.7 cum and fine aggregates @ 0.47 cum, super plasticiser @ 3lts confirming to IS-9103-1999 reaffirmed 2008 in layers of not more than 15 cms thick, well consolidated including centering, formwork, vibrating, curing, smooth finishing to the required plumb and face in C.M.1:3 proportion wherever necessary etc., complete as per design and specifications etc., complete for top rib and top dome or top slab (exclusive cost of steel and fabrication charges)

1.54

-

23719.39

... More
Labour charges for fabricating M.S. bars/tor steel bars of all sizes including cleaning, straightening, cutting, bending, hooking, placing in position, tying as per design including cost of binding wire, hoisting etc., complete for RCC over head tank only, including conveying steel rods from the departmental stores to work spot with all lead and lift & returning the balance material to Departmental Store (for all stages) etc. complete.. PHESR P NO 44 I No 4.59.1)

1.5

-

116790.3

... More
Providing and fixing M.S ladder 45 cms wide with 65 x 65 x 65 mm sized angle iron and 20 mm MS bars at 25 cms center to center duly fixing by holes to full depth of angle and welding with necessary supports and angle iron of same section at braces, including fixing in ground with CC 1:2:4 bed of size of 0.60 x 0.45 x 0. 23 mm and two coats of nonpoisonous anticorrosive bituminous paint as directed (including inserting in the angle iron and welding ) outside O.H.TPHESRI No 4.62

16

-

32049.6

... More
Ladder inside the container. Providing anodized aluminum ladder using 65 mm x 32 mm (approximately) “C” section x 3.0 mm for ladder side channels and 25 mm dia fluted pipe for Rungs at 250 C/C , ladder fixed at an angle of 70 degrees to Horizontal including necessary 25 mm dia GI struts with necessary GI fatteners for backing the latter to the tank walls to prevent buckling of the ladder with necessary CC 1:2 :4 bed for embedding the ladder bottom completePHESRI No 4.63

3

-

10226.7

... More
Providing and fixing 60 x 60 cms MS inspection door with necessary MS frame made out of MS angle 50 x 50 x 6 mm and MS shutter of 31.50 mm or BG 10 thick with hinges on top and locking arrangement, painting etc., complete (for RCC overhead tank and GLSR) PHESRI No 4.66

1

-

1999.8

... More
Providing and fixing enameled gauge plate 3mm thick 2.50M high and 0.23m wide with plastic float with thick plastic indicator and flexible nylon wire, painting figures with approved paint etc., complete to the required height (For every additional 0.50m or part there of add Rs. 100).PHESRI No 4.67

1

-

3720.2

... More
Providing and fixing copper lighting arrester with five spikes and 20mm dia copper tube or suitable length and aluminium strip of size 25mm x 3 mm including grounding as per KEB specifications. The aluminum strip is to be encased in GI conduit pipe of 40 mm dia 6 m long , suitably jointed by collars with all specials fixed to one of the columns etc., complete upto 6.00m (P-50/15) staging.

1

-

10609.5

... More
Providing 2 coats of snowcem of approved colour and shade over one coat of primer including curing etc., complete for RCC overhead tanks

147.91

-

34655.31

... More
Providing 15mm thick cement plaster in single coat with cement mortar 1:3, to brick masonry including rounding off corners wherever required smooth rendering, : Providingand removing scaffolding, including cost of materials, labour, curing complete as per specifications. CM 1:3 PHESRI No 9.08

62.71

-

16141.55

... More
Supplying, and Fixing CI puddle flanges confirming to IS 7181-1986 with latest amendments in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc complete 80mm

4

-

9486.4

... More
Supply and delivery at site CIDE pipes ISI marked (horizontal CIUDF) of 2.75-meter length, 80 mm dia as per ISI 181/ 1986 with latest amendments if any, the flange should be drilled as per IS 1538/ 1976, the pipes should bear ISI marking on them.

16

-

49280

... More
Supply and delivery at site CIDE pipes ISI marked (horizontal CIUDF) of 1.-meter length, 80 mm dia as per ISI 181/ 1986 with latest amendments if any, the flange should be drilled as per IS 1538/ 1976, the pipes should bear ISI marking on them.

10

-

13200

... More
Painting new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade complete as per specifications. ("ii) English and Roman - Hyphen and the like not to be measured and paid for" MORTH Specification No.801. ( PWD SR 2018-19 P No 193 I No 24.10 )

2500

-

1925

... More
bolt nuts with washers

30

-

2135.7

... More
Rubber Ibnsertion Sheet (3mm)

20

-

1720

... More
Earth work excavatoin for water Supply & Sanitary lines, Electrical conduits either in pits or pipe line trenches (upto 600mm Trench width) as per drawing and technical specification, including setting out, construction of shoring, strutting, barricading, danger lighting, bracing, using sight rails & boning rods at every 100 mm whevere necessary removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench, including backfilling the excavated earth to the extent required and utilising the remaining available excavated earth locally for the work. in the following strata classifications by Mechanical Means ( RWS SR , I no.2.23.1)

1035.34

-

148053.62

... More
Earthwork excavation for pipeline trenches including depositing on bank upto a lead of 50 mtrs and depth up to 2.00 mtrs. Including shoring and strutting, danger lighting and using sight rails and boning rods at every 100 mtrs. Wherever necessary as directed in the following strata. (Manual Means) ( RWS SR , I no.2.22.1)

443.72

-

127880.1

... More
Cutting of road surface for pipeline trenches and disposing of the excavated stuff as directed including barricading, danger lighting etc. in the following classification Cutting Asphalt Road Surface.( RWS SR , I no.2.26.2)

133.65

-

79682.13

... More
Providing and laying in position plain cement concrete of grade M 15 with cement @ 240kgs, with 20mm and down size graded granite metal coarse aggregates @0.878cum and fine aggregtes @ 0.53cum, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation,plinth and cills, ncluding cost of all materials, labour, HOM of machinery, curing complete as per specifications..( RWS SR , I no.4.04)

29.7

-

192753

... More
Supplying PVC Pipes conforming to IS 4984-1995 with latest amendments and conveying to work siteincluding loding and unloading at both distination and rolling,lowring in to trenches,laying tre to line and jointing of pipes and specials by electrofusion welding,including encasing the pipe aroud to a depth not less than 15 cms with soft gravel or selected earth Etc complete (RWS SR I.No.10.01.1)63 mm Dia 6.00 Ksc

190

-

25707

... More
Supplying PVC Pipes conforming to IS 4984-1995 with latest amendments and conveying to work siteincluding loding and unloading at both distination and rolling,lowring in to trenches,laying tre to line and jointing of pipes and specials by electrofusion welding,including encasing the pipe aroud to a depth not less than 15 cms with soft gravel or selected earth Etc complete (RWS SR I.No.10.01.1)75 mm Dia 6.00 Ksc

3103

-

522234.9

... More
Supplying PVC Pipes conforming to IS 4984-1995 with latest amendments and conveying to work siteincluding loding and unloading at both distination and rolling,lowring in to trenches,laying tre to line and jointing of pipes and specials by electrofusion welding,including encasing the pipe aroud to a depth not less than 15 cms with soft gravel or selected earth Etc complete (RWS SR I.No.10.01.1)90 mm Dia 6.00 Ksc

359

-

78585.1

... More
Refilling the basement and pipeline trenches with selected available earth from trench excavation including watering, Consolidation in layers of 15 cm thick including disposing of the surplus earth with all lead & lifts. ( RWS SR , I no.2.25)

443.72

-

50273.48

... More
Giving hydraulic test for C.I / R.C.C /P.V.C / H.D.P.E or A.C pipelines to the pressure equal to 2 times the working pressure includng cost of supply of water. ( RWS Sr , I.no 10.07 )Up to 80mmdia

3293

-

16662.58

... More
Giving hydraulic test for C.I / R.C.C /P.V.C / H.D.P.E or A.C pipelines to the pressure equal to 2 times the working pressure includng cost of supply of water. ( RWS Sr , I.no 10.07 )above 80mm & upto 100mm

359

-

2290.42

... More
Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments( RWS Sr , I.no 12.05 )65mm

15

-

20325

... More
Providing Sluice valve/ scour valve confirming to IS 1538 (Part-I to XXII) 1978 with latest amendments if any cost of all materials, labour charges etc. complete.( RWS Sr , I.no 15.59 )Size 80 mm

8

-

23200

... More
Providing Sluice valve/ scour valve confirming to IS 1538 (Part-I to XXII) 1978 with latest amendments if any cost of all materials, labour charges etc. complete.( RWS Sr , I.no 15.59 )Size 100 mm

2

-

7600

... More
KSRB13-5 • Providing and fixing water meter with stop cock, jam nut, socket in G. I pipe line including cutting and threading the pipe and making long screws including cost of all materials, labour, HOM and testing complete as per specifications.Specification No.KBS 13.2.19/13.16( PWD SR , I no.13.22)

45

-

65340

... More
Supply and fixing of HDPE water meter box to protect the water meter of class 'B: multijet type of size 15 to 32mm including HDPE box with base dia 300mmxlid dia 200mmxheight 250mm with openable lid and the cover is buried below GL with lid flush with GL including earthwork excavation for 600mmx600mm and base sand filling for 100mm thick over which the cover is placed and enclosed by PCC 1:2:4 using 12 to 20mm BG jelly for an height of 150mm and refilling with excavated earth for balance 100mm height,disposal of excess earth with all lead and lifts etc complete as per drawing enclosed ( RWS SR, I no.15.113)

45

-

24750

... More
Earthwork excavation by manual means for foundation of buildings, culverts, water supply and sanitary lines and electrical conduits etc, either in pits or in trenches 1.5m and above in width, in hard soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. including breaking of clods complete as per specifications. (RWS SRI No: 2.05)

4.05

-

1995.84

... More
Providing and laying in position plain cement concrete of grade M 10 with OPC cement @ 220kgs, with 40mm and down size graded granite metal coarse aggregates @0.892cum and fine aggregtes @ 0.465cum machine mixed, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation including cost of all materials, labour, HOM of machinery, curing complete as per specifications. (RWS SRI No 4.02)

0.45

-

2778.93

... More
Providing and laying in position reinforced cement concrete of Design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregtes @ 0.460 cum, with super plasticisers @ 3 liters confirming to IS 9103-1999 reafirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick,vibrated for all works in foundation for footings, pedastals, retaining walls, return walls, walls (any thickness ) including attached pilasters, columnspillars, posts, struts, buttresses, bed blocks,anchor blocks & plinths etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. (RWS SR I No 4.08)

1.69

-

11226.5

... More
Providing T.M.T steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid) including for OHT & reservoier, cost of materials, labour, HOM of machinery complete as per specifications. (RWSSRI No 4.59.1)

0.08

-

6228.82

... More
Supply and Fixing of Cast Steel Double Flanged Dual plate check valve Class 150 Conforming to API 594 with latest amendments as detailed below of following diameters and types and conveying to work site, loading, unloading, stacking etc., complete with all lead and lift. The rates are inclusive of cost of Bolts and Nuts. (RWS SR I.No. 15.106.1(A))

2

-

9136.6

... More
Supply and delivery of Woltman model with removal mechanism water meters confirming to ISO 4064 part I,II,III class B or IS 779 and IS 2373 with life cycle test certificate from FCRI/ NABL accredited lab. The water meters shall have magnetic drivers or mechanical drivers and shall be versatile for installation in any position. The meters shall be hydrodynamically, hydrostatically balanced. The runner, runner chamber, pointer of the meter shall be as per ISO 4064 class B specification. Dry dial excavated counter housing fully protected against flooding ensuring easy reading in all climates. Note: the above rates are basic rates inclusive of transportation charges, earth work excavation, labour charges, cutting and threading, conveyance, welding and hire charges for tools and plants ets., complete.[RDW&S SR 2019-20 Chapter No: 10 Item No: 15.40]

1

-

25531

... More
Supply and installation of water connections to individual houses with water meter point (which shall be fixed about one meter from customer boundary) and includes civil works like Earthwork excavation for the pipeline trenches for laying of MDPE /GI pipes of 20 mm diameters for the house connection in all types of soils, disintegrated rock, soft rock,, boring the wall surfaces comprising of BBM or SSM for conveying the pipelines to customer property, refilling etc. Complete supply and laying of MDPE pipes with special such as PVC saddles of approved make all specials such as GI tee, GI elbow, GI coupler, stopper etc, and SS tap

94

-

467838



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.