Karnataka State Road Transport Corporation Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Karnataka State Road Transport Corporation - KSRTC Tender

Civil And Construction
Opening Date12 Dec 2022
Closing Date30 Dec 2022
Tender Amount₹ 7,54,14,661 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of Labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. If the height of embankment construction is more than 1.50 m add 5% per m� for every 1.50 m height or part there off Deduct 5% per m� if rollers are not used and tamping is done manually Add 8% per m� for works under foul & sullage situation SRP- Vol-I (7/1.8)

7476.45

-

3005532.9

... More
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20mm nominal size graded crushed coarse aggregates - SRP Vol-I (It No 2.1.4 Pg No. 15)

6.68

-

38263.04

... More
Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ( For Foundation upto plinth (a) isolated ( For columns corrigendum-3 Sl.No. 1/a)

168.86

-

1128133.4

... More
Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates( For columns corrigendum-3 Sl.No. 8)

140.3

-

1475394.8

... More
Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates( For Plinth beams corrigendum-3 Sl.No. 1a)

23.68

-

219726.72

... More
Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesLintal Beam, Roof Beam ( For columns corrigendum-3 Sl.No. 8)

256.75

-

2541208.8

... More
Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates( For Roof slab of buildings beams corrigendum-3 Sl.No. 14)

83.3

-

772940.7

... More
Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately). SRP - Vol-I (17/2.5.12 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ( For chejjas, canopy & other architectural projections of minor sections of buildings beams corrigendum-3 Sl.No. 14))

5.23

-

46911.53

... More
Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot ressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991.from manufacturer complete as per spcification. 35 mm thick one side teak and one side commercial - SRP- Vol-II (106/12.57.5)

39.7

-

136766.5

... More
Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. SRP- Vol-II (100/12.12)

0.9

-

67809.6

... More
Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. SRP- Vol-II (105/12.54)

68.4

-

32490

... More
Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. SRP- Vol-II (106/12.55.2) with one side prelam.

18.9

-

53978.4

... More
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.SRP- Vol-II (85/34A)

6293.7

-

824474.7

... More
Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. SRP- Vol-II (14/6.8)

618.49

-

4137698.1

... More
Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (41/8.1.1)

885.3

-

188568.9

... More
Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (41/8.2.1)

1815.25

-

450182

... More
Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.SRP- Vol-II (91/11.44)

194.58

-

677332.98

... More
Providing, and fixing STAINLESS STEEL HAND RAIL rail 14 gauge pipes for ramps or staircase made out of stain less steel hollow pipes,using 50mm dia for vertical at 1.60 mtr C/C are fixed tot he ramp or steps by drilling with bolts and 100mm dia MS base plates 10mm guage for fixing of vertical pipes 4 Nos anchor bolts & 40mm dia pipes are fixed horizontally for two rows top,one pipes are fixed with vertical pipes another one are fixed elbows and 25mm dia pipes are horizontally for two rows top measure at equal intervals inc cutting welding bending wherever neccessary with suitable caps at tops btm and corners finishing with mat / shining etc complete inc cost and convinience of all materials,labour for all items of work HOM of equipement with all lead and lift, loading and unloading,transportation Charges and all other incidental charges etc direction Engineer In charge. (SRP 45/7.39)

600

-

300000

... More
Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. SRP- Vol-II (64/9.30)

349.61

-

837315.95

... More
Providing and laying Polished Glazed Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming (Payment for grouting of joints to be made separately). SRP- Vol-II (62/9.22.2) Size of Tile 600x600 mm

244.83

-

308730.63

... More
Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab,including cost of materials,labour,curing, polishing complete as per specifications. SRP- Vol-II (64/9.34)

45.13

-

53794.96

... More
Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 (1 cement : 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete. SRP- Vol-II (72/10.18)

105.16

-

322315.4

... More
Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. SRP- Vol-II (69/10.2)

103.42

-

27819.98

... More
Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) SRP- Vol-II (84/11.32)

89128.75

-

7397686.25

... More
Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge

2000

-

218000

... More
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

51.12

-

28422.72

... More
Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/ beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete - For Straight Portion SRP- Vol-II (71/10.15.1)

49.77

-

196044.03

... More
Providing, fabricating and fixing of stick type structural glazing using Aluminium Extrusions of 63.5mmx58.00mmx2.25mm of 1.75 kgs/mtr for vertical and horizontal members and 63.5mmx38.1mmx1.33mm of 0.759 kg/mtr, as outer frame with Electro Anodized Paint coated block finishing, using 6mm thick imported glass reflective hard coated ocean blue raw glass with all necessary accessories like ultra glass Silicon sealant of Space tape, Masking tape, Galvanized Anchor bolt, machine screws, 6mm thick M.S. angle 50mmx150mmx6mm M.S. Galvanized L brackets, structural sealant setting clocks, fasteners, wall connection etc., complete. (SRP 40/7.20) old SR 2018-19

21.33

-

141908.49

... More
Constructing brick maconary inspection chamber of internal dimention 600 X 450 mm, and depth of 600mm (Inner dimension) with modular bricks of class designation 75 in Cm 1:6 bed concrete 150mm thick with 1:3:6 with plastering 12 mm thick with CM 1:4.CC 1:2:4 cooping 75mm thick for fixing CI cover & frame etc. (excluding cost of CI frame & cover). SRP- Vol-V 187/8/T130A

18

-

78732

... More
Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. Note: Upto 110mm dia Coil shall be used. (For Grade PE80-PN 4.0,140mm dia, It No: 7.6/Pg 124)

330

-

160380

... More
Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 140mm dia., 6 kg/sqcm & class 3 (SRP VOL-V NO: 1.8, M010H, PG-134)

516

-

292572

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (48/8.40)

395

-

35550

... More
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m� over and including priming coat of exterior primer applied @ 2.20 kg/10 m�) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge

2500

-

340000

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and Smooth complete as per specifications and as per directions of Engineer in charge. SRP- Vol-II (50/8.51)

1500

-

124500

... More
Providing and placing on terrace polyethylene water storage tanks with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet uolet and over flow pipes includng cost of ll materials, labour transport charges HOM of equipments and testing complete as per specification SRP 96/13.78 (For 1000 ltr capacity)

8000

-

64000

... More
Providing and fixing chlorinated poly venyl chloride (CPVC) pipes confirming to IS 15778 having thermal stability for hot and cool watwr supply incl all CPVC plain brass threaded fittings incl fixing the pipe with clamp at 1.00 mtr spacing. This incl jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete 15mm dia(internal work exposed on wall) specification SRP 96/13.85.4 & 13.85.640mm dia

450

-

240300

... More
Providing and fixing chlorinated poly venyl chloride (CPVC) pipes confirming to IS 15778 having thermal stability for hot and cool watwr supply incl all CPVC plain brass threaded fittings incl fixing the pipe with clamp at 1.00 mtr spacing. This incl jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete 15mm dia(internal work exposed on wall) specification SRP 96/13.85.4 & 13.85.625 mm dia

470

-

148520

... More
Providing and fixing chlorinated poly venyl chloride (CPVC) pipes confirming to IS 15778 having thermal stability for hot and cool watwr supply incl all CPVC plain brass threaded fittings incl fixing the pipe with clamp at 1.00 mtr spacing. This incl jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete 15mm dia(internal work exposed on wall) specification SRP 96/13.85.4 & 13.85.620 mm dia

270

-

64530

... More
Providing and fixing chlorinated poly venyl chloride (CPVC) pipes confirming to IS 15778 having thermal stability for hot and cool watwr supply incl all CPVC plain brass threaded fittings incl fixing the pipe with clamp at 1.00 mtr spacing. This incl jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete 15mm dia(internal work exposed on wall) specification SRP 96/13.85.4 & 13.85.615mm dia

24

-

4320

... More
White Vitreous China Flat back wash basin size 450x 300 mm with single 15mm C.P. brass pillar tap SRP- Vol-II (125/14.7.7)

6

-

9636

... More
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete,including painting of fittings and brackets, cutting and making good the walls and floors wherever required. SRP- Vol-II (123/14.3.2) W.C. pan with ISI marked black solid plastic seat and lid.

12

-

58800

... More
Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. SRP- Vol-II (123/14.1.1)

4

-

16984

... More
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. SRP- Vol-II (128/14.31)

18

-

17478

... More
Providing and fixing C I Nahani trap of approved make confirming to ISI specifications and construction of cistern in CC 1:2:4 as per directions (Inclusive of cost of materials and fixtures) 12.5 cms x 7.5 cms SRP 90 / 12.113.2

32

-

9120

... More
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 15 mm nominal bore. (SRP Vol-II, P. 115 / I no.13.5.1)

20

-

6580

... More
Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) (40 mm nominal bore) SRP- Vol-II (115/13.4.3)

16

-

10896

... More
Providing and fixing brass stop cock of approved quality (15 mm nominal bore) SRP- Vol-II (115/13.3.1)

75

-

24450

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. SRP- Vol-II (60/9.11)

110.06

-

83865.72

... More
Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. SRP- Vol-II (65/9.38)

165

-

160710

... More
Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications

185

-

191845

... More
Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, griding the edge to half/full round wherever required, labour, curing complete as per specification. (SRP VOL-II (65/9.40)

307.95

-

348907.35

... More
Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all worksother than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. SRP vol-1/p-5/1.1

8122.5

-

568575

... More
Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m (SRP Vol-1 p- 8/1.14.1)

4917.78

-

358997.94

... More
Earth work in surface excavation for stripping, seating of bund, Road way by manual means for lowering & levelling the ground for all works other than foundation & depth in Ordinary rock and soft rock upto 300mm depth as per drawing and technical specifications, including setting out, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage& other appurtenances required to complete the work. SRP- Vol-I (5/1.2)

5000

-

2260000

... More
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. SRP- Vol-III (24/4.27)

1920

-

4596480

... More
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing. SRP- Vol-III (49/6.01) Ref. to MoRT&H Spec. 601 (Medium Works)

1280

-

5152000

... More
Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - SRP Vol-I (It No. 2.5.2 Pg No. 92)

474.06

-

3225788.68

... More
Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, , primer, sealant , curing of concrete slabs for 14- days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work SR Vol-III/p-138/20.29

1344

-

8752128

... More
Supplying, fitting and placing Mild steel reinforcement complete in sub structure as per drawing and technical specification SRP- Vol-III ( P.99/ I.No.13.2)

101.9

-

8015657.8

... More
Vaccum de-watering with vaccum pump and suction mat and compaction with skin floater clubbed with floating disc including cost of generator, HOM of machinery, Screed Vibratory, Power Floater, blade and disc etc., with all lead and lift. (SRP 2018-19 Item No.22.7 Pg 176)

6400

-

435200

... More
Providing and laying heavy duty cobble stones 75mm thick interlock pavers, using cement and course sand for manufacture of blocks of approved size, shape and colour with a minimum compressive strength of 281 kg per m2 over 50mm thick sand bed (average thickness) and compacting with plate vibrator having 3 tons compaction force thereby forcing part of sand nderneath to come up in between joints, final compaction of paver surface joints into its final level, including cost of materials, labour and Usage charges of machinery complete as per specifications. SRP- Vol-II (64/9.32)

2382

-

2727390

... More
Supplying S&S RCC SPUN / VIBRATED CAST PIPES (REINFORCED) pipes NP-3 Class conforming to IS:458-1988 with latest amentments using ordinary portland cement, for sanitary works and conveying to work site, rolling and lowering into trenches, laying true to line and level including loading and unloading at both destinations and jointing of pipes and specials, perfect linking of joints with jack to correct position including cost of jointing materials, i.e, rubber rings conforming to IS: 5382 for S&S RCC pipes, with all leads and lifts as directed and giving necessary hydraulic test as per ISS to the required pressure and commissioning etc. complete. (Contractor will make his own arrangements for procuring water for testing). Before the execution of the work, the contractor shall carry out the survey. SR vol-5/T050/p-185/3.1 300 mm dia. Vol-v 3.2 T050B

55

-

61325

... More
Supplying S&S RCC SPUN / VIBRATED CAST PIPES (REINFORCED) pipes NP-3 Class conforming to IS:458-1988 with latest amentments using ordinary portland cement, for sanitary works and conveying to work site, rolling and lowering into trenches, laying true to line and level including loading and unloading at both destinations and jointing of pipes and specials, perfect linking of joints with jack to correct position including cost of jointing materials, i.e, rubber rings conforming to IS: 5382 for S&S RCC pipes, with all leads and lifts as directed and giving necessary hydraulic test as per ISS to the required pressure and commissioning etc. complete. (Contractor will make his own arrangements for procuring water for testing). Before the execution of the work, the contractor shall carry out the survey. SR vol-5/T050/p-185/3.1 450 mm dia. Vol-v 3.5 T050E

77

-

162855

... More
Supplying S&S RCC SPUN / VIBRATED CAST PIPES (REINFORCED) pipes NP-3 Class conforming to IS:458-1988 with latest amentments using ordinary portland cement, for sanitary works and conveying to work site, rolling and lowering into trenches, laying true to line and level including loading and unloading at both destinations and jointing of pipes and specials, perfect linking of joints with jack to correct position including cost of jointing materials, i.e, rubber rings conforming to IS: 5382 for S&S RCC pipes, with all leads and lifts as directed and giving necessary hydraulic test as per ISS to the required pressure and commissioning etc. complete. (Contractor will make his own arrangements for procuring water for testing). Before the execution of the work, the contractor shall carry out the survey. SR vol-5/T050/p-185/3.1 750 mm dia. Vol-v 3.8 T050H

70

-

243810

... More
Supplying S&S RCC SPUN / VIBRATED CAST PIPES (REINFORCED) pipes NP-3 Class conforming to IS:458-1988 with latest amentments using ordinary portland cement, for sanitary works and conveying to work site, rolling and lowering into trenches, laying true to line and level including loading and unloading at both destinations and jointing of pipes and specials, perfect linking of joints with jack to correct position including cost of jointing materials, i.e, rubber rings conforming to IS: 5382 for S&S RCC pipes, with all leads and lifts as directed and giving necessary hydraulic test as per ISS to the required pressure and commissioning etc. complete. (Contractor will make his own arrangements for procuring water for testing). Before the execution of the work, the contractor shall carry out the survey. SR vol-5/T050/p-185/3.1 -1200 mm dia SRP- Vol-v (3.13 T050M)

25

-

180225

... More
Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (41/8.2.2)

2502.82

-

575648.6

... More
Constructing brick maconary inspection chamber of internal dimention 600 X 600 mm, and depth of 600mm ( Inner dimension ) with modular bricks of class designation 75 in Cm 1:6 bed concrete 150mm thick with 1:3:6 with plastering 12 mm thick with CM 1:4.CC 1:2:4 cooping 75mm thick for fixing CI cover & frame etc. (excluding cost of CI frame & cover). SRP- Vol-V 187/9/T130B

3

-

14931

... More
Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). SRP- Vol-I (15/2.2.1.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates

67.64

-

436773.12

... More
Supplying and filling in plinth with sand under floors, foundation of Bridges including watering, ramming, consolidating and dressing complete 100mm downsize Boulders. SRP- Vol-II (amd p10/6.4)

8

-

20488

... More
Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will makehis own arrangements for procuring water for testing) etc.Note: Upto 110mm dia Coil shall be used. SRP- Vol-V 124/7.4/K056D

134

-

41674

... More
Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. forPVC pipes 110mm dia., 6 kg/sqcm & class 3

80

-

31520

... More
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20mm nominal size graded crushed coarse aggregates - SRP Vol-I (It No 2.1.4 Pg No. 15)

0.78

-

4467.84

... More
Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes,collars, cap etc., complete). SRP- Vol-V (151/1 to 1.9)0-50 Mtrs.

50

-

14500

... More
Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes,collars, cap etc., complete). SRP- Vol-V (151/1 to 1.9)50-100Mtrs

50

-

18200

... More
Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes,collars, cap etc., complete). SRP- Vol-V (151/1 to 1.9)100-150 Mtrs.

50

-

19350

... More
Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes,collars, cap etc., complete). SRP- Vol-V (151/1 to 1.9)150-200 Mtrs.

50

-

22450

... More
Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes,collars, cap etc., complete). SRP- Vol-V (151/1 to 1.9)200-250 Mtrs.

50

-

26350

... More
Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes,collars, cap etc., complete). SRP- Vol-V (151/1 to 1.9)250-300 Mtrs.

50

-

27900

... More
Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes,collars, cap etc., complete). SRP- Vol-V (151/1 to 1.9)300-350 Mtrs

50

-

31000

... More
Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes,collars, cap etc., complete). SRP- Vol-V (151/1 to 1.9)350-400 Mtrs

50

-

34850

... More
Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes,collars, cap etc., complete). SRP- Vol-V (151/1 to 1.9)400-500 Mtrs

100

-

93000

... More
Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes andspecials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 160mm dia., 6 kg/sqcm & class 3 SRP- Vol-V 134/1.9)

130

-

77870

... More
Providing and conduting geophysical survey charges.

2

-

1900

... More
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators,providing weep holes wherever necesary, including all lead & lifts, costof all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).SRP- Vol-I (17/2.4.1) Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates

9.91

-

58270.8

... More
Fencing with G.I. barbed wire Angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. With G.I. barbed wire SRP- Vol-II (95/11.57.1)

3375

-

50625

... More
Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc.complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.SRP- Vol-II (81/11.16.2)

6160

-

837760

... More
Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m�) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.. (Apex Paint) SRP- Vol-II (45/8.28)

1115

-

73590

... More
Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes andspecials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 63mm dia., 6 kg/sqcm & class 3 SRP- Vol-V 134/1.4)

280

-

42840

... More
Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. forPVC pipes 90mm dia., 6 kg/sqcm & class 3

600

-

168600

... More
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (45/8.25)

350

-

36750

... More
Supplying S&S RCC SPUN / VIBRATED CAST PIPES (REINFORCED)pipes NP-3 Class conforming to IS:458-1988 with latest amentments using ordinary portland cement, for sanitary works and conveying to work site, rolling and lowering into trenches, laying true to line and level including loading and unloading at both destinations and jointing of pipes and specials, perfect linking of joints with jack to correct position including cost of jointing materials, i.e, rubber rings conforming to IS: 5382 for S&S RCC pipes, with all leads and lifts as directed and giving necessary hydraulic test as per ISS to the required pressure and commissioning etc. complete. (Contractor will make his own arrangements for procuring water for testing). Before the execution of the work, the contractor shall carry out the survey. RCC NP3 Class pipe of 1000 mm dia. (SRP Vol-5/ I.no.3.11, T050K)

4.5

-

26190

... More
Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth.SRP Vol-2, (P.70/I.No.10.8)

6.75

-

10881

... More
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer(Vol-2/ P.125/ INo.14.7a)

6

-

21594

... More
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and makinggood the walls and floors wherever required One urinal basin with 5 litre white P.V.C. automatic flushing cistern SRP- Vol-II (123/14.4.1)

6

-

21216

... More
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cistern (Vol-2, P. 124/14.5.1)

6

-

39768

... More
Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box (P-2/2.2.1)

25

-

6275

... More
Do-Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box (P-2/2.2.2)

50

-

18050

... More
Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box (P-2/2.2.3)

50

-

27100

... More
Open Conduit System :Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25mm dia 2mm thick 1.1. 2

3200

-

256000

... More
Do-32mm dia 2.5mm thick

100

-

10000

... More
Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300mm .... etc. as required. 25mm 1.8.2

50

-

1400

... More
Do- 32mm (3/1.8.3)

15

-

615

... More
Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 1-3Way 3.3.1

5

-

455

... More
Do-4-5Way 3.3.2

5

-

610

... More
Do- 8Way 3.3.4

5

-

975

... More
Do-10-12Way 3.3.5

5

-

1385

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3Way 3.4.1

10

-

1230

... More
4-5Way 3.4.2

10

-

1380

... More
6Way 3.4.3

10

-

2120

... More
8Way 3.4.4

10

-

2500

... More
10-12Way 3.4.5

25

-

8125

... More
16-18Way 3.4.6

6

-

2124

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module 3.5.1

15

-

2280

... More
Do-4 module (9/3.5.2)

15

-

2625

... More
Do- 6 Module (9/3.5..3)

10

-

2440

... More
Do- 8 Module (9/3.5.4)

15

-

4530

... More
Do- 10-12 Module (9/3.5.5)

30

-

10890

... More
Do- 16-18 Module (9/3.5.6)

6

-

2418

... More
Supplying and fixing modular switch/ socket/ stepped electronic fan regulator/dimmer/telephone socket etc., on existing modular switch plate as per IS 3854 and IS 1293 6 amps one way (10/3.6.1)

500

-

44000

... More
Do- 6Amps 3 way socket (10/3.6.3)

100

-

16200

... More
Do- stepped fan regulator (10/3.6.4)

20

-

6260

... More
Do- 16Amps one way switch(10/3.6.8)

10

-

2490

... More
Do- 6Amps bell push (10/3.6.9)

3

-

477

... More
Do- 32 Amps DP switch (10/3.6.10)

15

-

5625

... More
Do- 6/16 Amps universal socket (10/3.6.11)

100

-

24900

... More
Do- TV / Telephone socket (10/3.6.12)

10

-

1470

... More
Do- RJ45/ IO outlet cat 6 (10/3.6.13)

35

-

7385

... More
Supplying and fixing metal Fan box with Round Hook. (3/1.12)

20

-

3260

... More
Supplying PVC /GI flexible conduit pipe ..mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and the either end of the pipe terminated completely 25mm (3/1.9.2)

50

-

1550

... More
Do- 32 mm (3/1.9.3)

25

-

1025

... More
Wiring for lighting power circuit using one of FRLS PVC insulated 1100v grade multistrand Copper with low conductor resistance single core cable in open or concealed system of wiring with specified IS 694 : 1990 & confirming to GTP of GROUP A 1.5 Sqmm (5/2.3.2)

2000

-

52000

... More
Do- 2.5 sqmm (5/2.3.3)

3250

-

130000

... More
Do- 4 sqmm (5/2.3..4)

1500

-

88500

... More
Do- 6 sqmm (5/2.3.5)

100

-

8700

... More
Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable 2 Pair (27/8.2.1)

100

-

1300

... More
Do- 5Pair (27/8.2.5)

100

-

5800

... More
Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable RG -6 (27/8.3)

100

-

4200

... More
Supplying and drawing UTP –CAT 6E LAN cable (27/8.1)

1000

-

34000

... More
Supplying 4mm thick plastic sheet with necessary nitches for fixing switches regulators etc., and fixing on existing wooden or metal box using N.F screws (10/3.8)

5000

-

1450

... More
Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI > 80. Power Input: 220-240V@ 50/60Hz & Power factor > 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4'- 20/22 w (34/11.3.2)

100

-

74000

... More
Do- LED light fitting 2 x 4' - 20 /22 w (34/11.3.2)

20

-

23940

... More
Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI > 80. Power Input: 220-240V @50/60Hz & Power factor >0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition) LED square or round down light 15-18W (34/11.5.3)

12

-

14988

... More
LED Street light : .Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT > 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire > IK08. Power Factor >0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency>1301m/w, nominal CRI >75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40 Watts 12.8.2

20

-

73020

... More
LED Flood Light : .Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT > 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire > IK08. Power Factor >0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficiency> 1301m/w, nominal CRI >75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.LED Flood Light 100w(P67/12.9.2)

10

-

81720

... More
Do- 120watts. (P67/12.9.3)

6

-

57378

... More
Do- 200 watts. (P67/12.9.6)

8

-

156496

... More
Supplying capacitor type ceiling fan complete with down rod blades shackle, canopies etc., for operation on 230 volts, 50 cycle, single phase AC supply conforming to ISS –374-1979 and with double ball bearing 48” sweep (1200mm)Regular model system (46/7.3.1)

20

-

41700

... More
Do- 56" sweep(1400 mm) Regular model (46/7.3.2)

4

-

8680

... More
Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable for operate on 230V 50za, AC supply complete 15” Sweep (450mm) ((46/7.2.2))

4

-

16504

... More
Supplying exhaust fan of 1440 RPM of 300mm (12”) size with bracket blades complete for light duty suitable for operate on 230 V 50 Hz , AC supply(46/7.1)

4

-

4800

... More
Fixing all types and all capacities of fluorescent /false ceiling spot light /CFL /LED fitting s indoor on the wall /ceiling /raffters /girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps On Wall /Ceiling/Rafter/Girders (45/13.7.1)

132

-

15708

... More
Supplying and Fixing........mm dia class A GI pipe bracket up to 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires. Using 32mm dia G.I.Pipe (45/13.2.2)

20

-

22720

... More
Fixing halogen/metal halide/SVL/IL floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires (45/13.5)

24

-

4536

... More
Fixing charges of post top/ Gate/ Garden fittingLED on the existing CI /GI or any other pipe using required size of reducer wiring using suitable wires etc., complete (45/13.6)

24

-

3984

... More
Fixing a ceiling/ wall mounting fan of all capacities and all types to the existing S hook with fan regulator to the existing board together with supplying and fixing a 5ampers ceiling rose, necessary length of 23/0.0076 inch PVC insulated twin twisted copper wire and wiring(45/13.10)

24

-

3888

... More
Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 amps ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire(46/13.14)

8

-

3456

... More
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and ‘C’ Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K complete wiring as required confirming to IEC 60898 5-32 Amps SP (13/5.17.1)

15

-

7845

... More
Do-40 Amps SP (13/5.17.2)

12

-

8712

... More
Do-50-63 Amps DP (13/5.17.3)

10

-

7340

... More
Do-6-32 Amps DP (13/5.17.4)

12

-

13236

... More
Do-50-63 Amps DP (13/5.17.6)

10

-

13760

... More
Do-6-32 Amps TPN (13/5.17..7)

12

-

21324

... More
Do-40 Amps TPN(13/5.17.8)

6

-

14358

... More
Do-50-63 Amps TPN(13/5.17.9)

6

-

14394

... More
Supplying, fixing and wiring Earth Leakage Miniature circuit breakers (ELMCB) 240/450 V with up to 300 m A sensitivity on existing wood/ panel board 32-40 amps 4 pole (13/5.20.3)

3

-

8478

... More
Do- 63 Amps 4 pole 13/5.20.3)

2

-

6116

... More
Supplying and fixing regular MCB distribution boards on wall/ wood board/flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB ‘s single phase /3 phase/ single door with powder coated painting Made out of 14 SWG MS enclosure. Double Door 4 Way SP & N (28/5.18.5)

10

-

13680

... More
Do- 8way SP &N Double door (28/5.18.7)

10

-

16950

... More
Do- 12way SP &N Double door.(28/5.18.7)

10

-

20670

... More
Supplying and fixing Moulded case circuit Breaker (MCCB) over the existing wood/panel board using necessary screws bolts, nuts and wiring complete. Protection of overload and Short circuit with thermal agnetic/Microprocessed release and Earth Fault as per IS-13947. (lcu = lcs) 100 Amps 25 KA FOUR POLE (26/5.14.7)

4

-

33060

... More
Do- 125 25kA FOUR POLE (26/5.14.8)

2

-

20144

... More
Supplying, fixing and wiring 50/5to 400/5amps 5 VA burden current transformer. Class 0.5 accuracy with Tape wound(29/5.34)

9

-

4545

... More
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C 50 Hz 12/24 V.D.C ((29/5.38)

9

-

4176

... More
Supplying fixing and wiring heavy duty low voltage capacitors conforming to IS 2834, 3 Phase 400/440 Volts grade for power factor improvement of rotating machinery. (29/5.37)

25

-

10800

... More
Supplying fixing and wiring 3 digital ammeter / voltmeter. (29/5.29) Make: L&T / Meeco / C&S

3

-

3840

... More
Supplying fixing and wiring automatic power factor controller fully static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stage and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded comprehensive displays with large three place LED display long term memory for setting protection for over voltage power factor correction fault and no Voltage to connect/ disconnect banks, with automatic recognition or with standard programs (30/5.39)

1

-

19440

... More
Supplying of multi function digital meter with three line back light LCD type display for voltage, current, frequency, power, power factor KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and class 0.5s accuracy (29/5.33 )

1

-

8370

... More
Fabricating supplying and mounting MS box made out .. SWG suitable for floor/ wall mounting fully weather proof with provision for better heat dissipation, provided with hinged front cover equipped with tamper proof locking arrangement, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enamelled metal paint etc., complete. 14 SWG (30/5.42.1)

10000

-

4300

... More
Do- 16 SWG (30/5.42.2)

200000

-

76000

... More
Supplying .. amps rated 3 phase with neutral bus bar using requirement capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/ FRP/ DMC insulator which are mounted on power coated 40x6mm M.S flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 100 Amps 4x30x6mm aluminum strips (30/5.40.1)

2

-

4428

... More
Supplying and fixing angle iron frame work fabricated out of M.S angle iron.. and M.S flat… with bolts, washers etc., and painted with 2 coats of red oxide and then two of approved paint 40x40x6mm (30/5.41.1)

20

-

5500

... More
Do- 50x50x6mm. (30/5.42.2)

8

-

2848

... More
Do-50x100x50x6mm C Channel (30/5.42.4)

10

-

6800

... More
Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufacture with electrolytic grade copper with fixable copper with low resistance conductor confirming to table 3 class 5 of IS : 8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage up to 110 Volts as per IS 694 : 1990 & Confirming to GTP of GROUP A v (7/2.6.2) 3C x 4Sqmm

112

-

18704

... More
Fabricating supplying and erection Testing and commissioning of ..16 Mtrs long Polygon high mast with single /Multiple telescopic sections having (minimum overlap distance of 1.5 times of top section) thickness as per BSEN 10025 grade S 35 JO /ASTM A572-50 steel sheet plate for shaft suitable to withstand a wind velocity of 47m/sec as per IS 875 part 3 (as per GA drawing) Base plate as per IS 2062 ASTM A572-50. The mast shall be Galavanized single HOT dip as per BSEN ISO 1461/ASTM A 123 with an average 70 microns as per IS 2629, and welded as per 5135 single L- Seam Joint. The mast shall have 2 way head frame withdie cast LM -6 pullyeys \, stainless steel axils, phosphors bearing bush press fixed with separate guides for 2 runs of 5mm dia stainless steel wire rope of AISI 304 Grade 7/19- core (Factor of safety as per TR no -7) 2.5 Sqmm EPR insulated PCP shethed trailing power cable all are housed inside the bottom shaft of mast with suitable locking arrangement. The mast shall have power tool operating on 230/415V, 50 Hz 1/3 phase reversible geared motor The mast shall have lantern of 2 segments suitable dia with max load carrying capacity as per IS 1239. The mast shall be erected on existing RCC footing. The mast shall be supplied with 3mm thick template lightning arrester of 1.2m length galvanized pipe with top arrow fitted on top of the head frame cover and GLS type aviation twin lamps fittings with wiring complete (excluding foundation ) as per technical data 16 Mtrs – Top 150mm and bottom 410mm dia(15/4.5.2)

1

-

174260

... More
Double Arm Bracket with 1000mm Standard 40/50mm dia (16/4.7.4)

2

-

4648

... More
Supply and erection of Suguna make three phase 7.5HP suitable stage submersible pumpset for borewell as per the directions of Engineer in charge of work.

1

-

35616

... More
supplying erecting testing & commission of OFF –LINE UPS system suitable for operation on 230V .50Hz, A/C supply with all accessories complete including batteries and wiring complete 5KVA OFF LINE UPS Two hour back up Excluding 6 x 150Ah batteries (57/10.2.5)

1

-

38661

... More
Supplying installation testing & commissioning of 12volts. AH batteries in poly propylene container for D.G sets. Low maintenance batteries, plate type 150 AH capacity .acid batteries (57/10.4.5)

6

-

162036

... More
Supplying and fixing of class A (medium duty ) GI pipe of wall thickness not less than 3.25mm on pole/ wall / drain crossing with necessary clamping arrangements for UG cable of 1.1 KV 50 mm (6.9.2)

20

-

7600

... More
Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete ( As per civil SR KSRB I-2 , P-7) In soil (Hard) (41/6.6.2)

500

-

51000

... More
Supplying and fixing regular MCCB distribution panel confirm to IS 8828, on wall /wood board/ flush mounting using required clamps, bolts, nuts etc., with provision for fixing of suitable type capacity MCCB’s as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440 Volts 3 phase 4 wire powder coated painting etc., complete with a provision for fixing of single /three phase suitable capacity MCCB/MCB’s as outgoings confirm to IS 8828 : 4 Way (27/5.16.1)

2

-

18338

... More
Supplying fully automatic star -delt starter unit push button type with suitable wires, 3 contractors, one adjustable thermal timer mounted on a common base plate held in steel enclosure for use on 400/440 volts 3 phase and wired after fixing to the existing wooden board for motor Up to 12.5 HP 24/5.2.1)5.2.1 : Upto 12.5 HP

1

-

6912

... More
Supply and fixing of 4 pole powder contactor with No/NC contacts on existing wood/ panel / board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as pe IS-13947 (25/5.13) 5.13 40 Amps

3

-

6378

... More
Supplying and fixing /replacing of 6/16/32amps electrical accessories on existing switch board (11/3.14.6)GROUP A 3.15.6 : 6Amps lamps holder

40

-

2520

... More
-Do-e) 6 Amps bakelite ceiling rose (11/3.14.5)

50

-

3150

... More
Supply and fixing of 4 pole powder contactor with No/NC contacts on existing wood/ panel / board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as pe IS-13947 (26/5.13.2) 6.12.3 60-70 amps

3

-

14778

... More
Supplying of on load change over switches 4 poles AC supply with AC-23A Duty 415 V, 50 Hz AC supply (25/5.11.4 ) 6.11.1 : Up to 200 Amps

1

-

12086

... More
Supplying, installing, testing and commissioning of Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514/ISO 3046/ ISO IS 1002/ISO 3046 Generator set specifications. Engine: Diesel generating set are rated at 1500RPM and conform to ISO 8 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade), Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation. Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation. Alternator: Alternator is suitable for operation at 1500 RPM, 415 V, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming to IS/IEC 60034-1. The Alternator is brush less type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have� 1.0% Voltage regulation (max) in static conditions- IP: 23 protections with insulation class F&H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads.Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lA for 'Load On' and 'Set Running', Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections Genset Controller:microprocessor based generator setmonitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied.Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight.Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,-Auto start mode accepts a ground signal from remotedevices to automatically start the DG set The remote start will also wake up the control system from sleep mode.Engine Starting -The control system supports automatic engine starting, Primary and back up start disconnects are achieved by battery charging alternator feedback or main alternator output frequency. Controller provide configurable time delay of 0-300 sees to start after remote start signal and time delay of 0-600secs prior to shut down after stop signal. Sleep mode increase battery life. Configurable current settings from low to minimize current draw when genset is not working. Engine Protective functions include, Configurable alarm output,microprocessor based generator setmonitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied.Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight.Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,-Auto start mode accepts a ground signal from remotedevices to automatically start the DG set The remote start will also wake up the control system from sleep mode.Engine Starting -The control system supports automatic engine starting, Primary and back up start disconnects are achieved by battery charging alternator feedback or main alternator output frequency. Controller provide configurable time delay of 0-300 sees to start after remote start signal and time delay of 0-600secs prior to shut down after stop signal. Sleep mode increase battery life. Configurable current settings from low to minimize current draw when genset is not working. Engine Protective functions include, Configurable alarm output,

1

-

618585

... More
Supplying erection testing and commissioning of AMF panel suitable for ...KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors undrilled bottom gland plate aluminium Bus Bar with the accommodation for. Amps 4 pole contactor for alternator with thermal O/L relay ... Amps 4pole contactor for mains HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic. Mains/generator voltage,. Capacity bypass switch and frequency sensing PCC 1301 controller with water temperature/Lube oil pressure /engine speed, Voltage /ampere/Frequency/KVA Running hour count No of start Fault indication over under speed Fails to start Low oil pleasure High engine temperature Under/Over Voltage over current , earth fault relay with indications for Mains on Load on Mains Battery charges on Push buttons AMf module by pass Mode Battery charger unit with inbuilt Auto/ Manual and Flat /Boost facility 62.5 KVA -125 kva (62/11.2.5)

1

-

107525

... More
Grounding Material Pipe Grounding GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg (BESCOM SER Part-III) (P-17/54.01)

8

-

6160

... More
Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each(BESCOM SER Part-III) (P-17/54.02)

8

-

5280

... More
Good Quality Salt for grounding purposes packed in 50 Kg gunny bag (BESCOM SER Part-III) (P-17/54.03)

12

-

3636

... More
Digging of Pit for providing GI Pipe type Earthing Hard Soil (BESCOM SER Part-IV) (P-1/1.6.2)

8

-

18136

... More
Supplying and running of GI /Copper strips for grounding connections, using necessary fixing materials as required 25x6 mm GI strip (40/6.3.2) (2019-20)

30

-

3450

... More
Do- 25x6mm. 25x3mm copper strip (40/6.3.6) (2019-20)

25

-

12625

... More
Do-600x600x3mm GI plate 25x3mm copper strip (40/6.3.10) (2019-20)

2

-

13800

... More
1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm)(BESCOM SER Part-III) (P-9/32.05)

0.5

-

91721

... More
Do- 25 sqmm 3.5 core .(BESCOM SER Part-III) (P-9/32.07)

0.25

-

45363

... More
Do- 50 sqmm 3.5 core (BESCOM SER Part-III) (P-9/32.05)

0.25

-

60602.75

... More
Do- 95 sqmm 3.5 core .(BESCOM SER Part-III) (P-9/32.05)

0.25

-

12851

... More
Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT cable 2.5 to 25sqmm (BESCOM SER Part-IV) (P-9/32.05)

1

-

16159

... More
Do- 35sqmm to 95sqmm In existing trench / duct (BESCOM SER Part-IV) (P-9/32.05)

0.51

-

12059.97

... More
Supply and laying double walled corrugated (DWC), HDPE pipe with necessary connecting sockets / Couplings/Tees/ Bends of same materials in existing trench as per IS 14930 part- II Suitable for drawing underground cable 63mm OD/ 50mm ID (63/7.20.3) 14-15SR

500

-

103000

... More
Do-90mm OD/ 76 mm ID (63/7.20.5) 14-15SR

250

-

82750

... More
Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes 1.5 Sqmm (P-43/6.17.1)

80

-

240

... More
Do- 2.5 sqmm (P-43/17.2)

80

-

320

... More
Do- 4. sqmm. (P-43/17.3)

80

-

560

... More
Do- 6 sqmm.(43/6.17.4)

40

-

280

... More
Do- 10sqmm. (43/6.17.5)

30

-

240

... More
Do- 16 sqmm.(43/6.17.6)

50

-

622

... More
Do- 25 sqmm Long Barrel. (43/6.17.7)

25

-

500

... More
Do- 50 sqmm Long Barrel. (43/6.17.8)

16

-

960

... More
Do- 70 sqmm Long Barrel. (43/6.17.9)

16

-

1520

... More
Do- 95 sqmm Long Barrel. (43/6.17.10)

16

-

2320

... More
11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975 95 Sqmm, (54 GI Wires - 2.5 mm Dia) (BESCOM SER Part-III) (P-10/36.01)

0.2

-

223123

... More
Distribution Transformer - 3 Phase, 11kV/433V - Stacked CRGO Core with Oil as per IS-1180 (Part-1): 2014 A. OPEN BUSHING TYPE 63 kVA, Aluminum Wdg, Star 2 (5 Star (BESCOM SER Part-III) (P-4/12.06)

1

-

176257

... More
Double Pole TC Set for erection of Transformer on RCC/PSCC 9 Mtr Long Poles as per IS-1977 For 25/63/100 kVA 4/5 Star Rated Transformer on PSCC Pole - 9 Mtr Long, 300 Kg WL - GI (BESCOM SER Part-III) (P-4/21.02)

1

-

25186

... More
RCC Pole - 9 Mtr Long, 150 Kg WL Sq Section (Dwg No. BESCOM/GM/QS&S/51 Dtd 24.11.2018) as per IS-785 (BESCOM SER Part-III) (P-1/1.02)

10

-

82260

... More
Supplying and errection of 11 kV, Horizontal Cross Arm - Galvanised Iron (BESCOM SER Part-III) (P-1/2.02)

10

-

5050

... More
Supply of Insulator as per IS-1445 for Ceremic, IS7935 for GI Pin, IEC-61109 for Polymeric 11 kV, 5 kN Composite/Polymeric Pin Insulator (24 mm dia FRP Rod) (BESCOM SER Part-III) (P-2/6.05)

20

-

4420

... More
Do- 9 DISC Insulator 45 kN porcelain (BESCOM SER Part-III) (P-2/6.09)

12

-

5640

... More
Supply GOS as per IS-9921, IS-1977 11 kV, 200 Amps Single Break GOS (Dwg No. BESCOM/GM/QS&S/23 Dtd 24.11.2018) (BESCOM SER Part-III) (P-8/24.01)

1

-

9125

... More
Supplying and Fixing ….. including all Hardware's etc. complete as per the standard technical specification of BESCOMGUY Set (33/5.8.7) (SER 14-15)

10

-

13200

... More
Supplying of ACSR Conductor as per IS-398 (Part - 2/1996) Rabbit ACSR (6/3.35 mm Al + 1/3.35 mm St), Std Wt: 214 Kg/KM (BESCOM SER Part-III) (P-3/7.02)

1.2

-

73818

... More
Supplying 11 kV, Jointing & Cable Termination Kit as per IS-13573 Heat Shrinkable Type Transition Jointing Kit for XLPE Cable 3Cx 95 Sqmm (BESCOM SER Part-III) (P-14/45.01)

2

-

19984

... More
Supplying ......TR split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacitors, relay and over load protector internal unit, with one indoor and one outdoor unit The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube. (High wall chorded/cordless) suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit. 5star. 2 Ton capacity.(P-24/6.8.6.)

3

-

236616

... More
Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C.(P-24/6.12.)

3

-

14943

... More
Supply, installation of 5/8" and 7/8" Hard drawn refrigerant pipe and insulation suitable for 11TR duct able split Air Conditioner.(P-25/6.24)

3

-

7461

... More
Supplying & filling refrigerant latest R-410 / R-32 for air conditioning equipment's. Which includes the labour & Nitrogen gas for pressure and leak testing. (P-26/6.31.)

6

-

3996



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.