Karnataka State Pollution Control Board Tender
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
Costs
EMD
₹ 1,90,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
KSPCB/2018-19/OW/WORK_INDENT84/CALL-2Tender No
KSPCB/2018-19/OW/WORK_INDENT84/CALL-2Tender Authority
Karnataka State Pollution Control Board ViewPurchaser Address
-Website
http://eproc.karnataka.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Same as above but for 30" (750mm) cabinet with 1 drawer & 2 shutter with telescopic channel inside along with SS 304 hinges and SS 304 Handle with adjustable shelves inside) - 2D2S30
The work should be executed as per detailed Technical Specification and direction of the Engineer in charge of this work
60
-
-
... More
Same as above but for 36" (900mm) cabinet with 1 drawer & 2 shutter with telescopic channel inside along with SS 304 hinges and SS 304 Handle with adjustable shelves inside) - 2D2S36
The work should be executed as per detailed Technical Specification and direction of the Engineer in charge of this work
19
-
-
... More
Same as above but for CORNER UNIT: Corner cabinet with 1 shutter with SS 304 Hinges and SS 304 Handles - 1S
The work should be executed as per detailed Technical Specification and direction of the Engineer in charge of this work
6
-
-
... More
Same as above but for SINK UNITS: Corner sink cabinet with 1 shutter with SS 304 Hinges and SS 304 Handles - Sink1S
The work should be executed as per detailed Technical Specification and direction of the Engineer in charge of this work
1
-
-
... More
Same as above but for 30" (750mm) sink cabinet with 2 shutter with SS 304 Hinges and SS 304 Handles - Sink2S30
The work should be executed as per detailed Technical Specification and direction of the Engineer in charge of this work
12
-
-
... More
Same as above but for 56" (1422mm) End sink cabinet with 2 shutter with SS 304 Hinges and SS 304 Handles - Sink2S56
The work should be executed as per detailed Technical Specification and direction of the Engineer in charge of this work
6
-
-
... More
Same as above but for REAGENT RACKS: Providing and fixing reagent racks of 2 Tier for island bench size of 10"D x 28.5"H inch. Refer individual lab details and drawings attached separately. - RR48
The work should be executed as per detailed Technical Specification and direction of the Engineer in charge of this work
11.1
-
-
... More
Providing and fixing SINKS: The sinks should be injection molded from Poly propylene co-polymer resin. Polypropylene is chosen to have very high resistance to attack from a wide range of chemicals and the ability to withstand temperatures up to 100 deg C. The impact resistance should be high which will minimize damage during and after installation. The sinks should be with self draining base and should be suitable for mounting on top or underside of the work benches. The sinks should be compatible to a vast number of acids, alkalis and reagents. This sinks shall have bottle trap with reducing coupler of size 51x31mm and with 50mm polypropylene pipe of one foot length. The bottle trap shall be of Laboratory grade polypropylene, unless otherwise specified, Overflows shall not be furnished for sink outlets unless specifically mentioned. Size 480mmx 380mm x 300mm
The work should be executed as per detailed Technical Specification and direction of the Engineer in charge of this work
19
-
-
... More
Water Taps - 3-way brass goose necked type: All faucets and valves for water service shall have a renewable unit containing all working components subject to wear, including a stainless steel replaceable seat and an integral adjustable volume control (designated by the suffix “AC”). The renewable unit shall be interchangeable among all faucets and valves for water service. The unit shall be capable of being readily converted from compression to self-closing, and vice versa, without disturbing the faucet body. The unit Shall be chemical resistant and built as per DIN 12918 having maximum working pressure of 10 Bar.Goosenecks shall have a separate outlet coupling with a 3/8" IPS female thread securely brazed to the gooseneck for attachment of serrated hose ends, aspirators and other outlet fittings. Rigid goosenecks shall have a 3/8" IPS male inlet thread The work should be executed as per detailed Technical Specification and direction of the Engineer in charge of this work
19
-
-
... More
Peg boards on sink: Acrylictransparent (10mm thick) or Stainless steel peg board with black colored pegs having a drip tray and flexible tube of at least 600 mm Length to drain the excess liquid from glass wares to sink. Pegboards shall be fixed on wall or on furniture at accessible height as per drawings and prevalent site situation. Size of peg board as per manufacturer's specs or SS pegboard with SS pegs
The work should be executed as per detailed Technical Specification and direction of the Engineer in charge of this work
19
-
-
... More
Providing and fixing for granite worktop 20mm thick gang saw water cut telephonic black granite in CM 1:4 proportion with a coat of rough plastering using CM 1:4, cut to required shape, pattern with paper joints, including front edge chamfer nosing at angle of 28 deg and smoothened, with 100mm backsplash finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, HOM of equipment etc., complete as per specification
The work should be executed as per detailed Technical Specification and direction of the Engineer in charge of this work
Page No 111 Item No 14.59
135
-
-
... More
Providing and fixing PVC Rubber Moulding of 4" height on tow space to prevent the direct contact of chemical on the cabinet body
The work should be executed as per detailed Technical Specification and direction of the Engineer in charge of this work
226
-
-
... More
Providing and fixing Anti-Vibration Table Finish of Top matching to lab table top. Approximate Size:900mm L x 750mm D x 900mm H and having 2 nos. of 5/15 amps switch and sockets. Trunking to be extended from edge to edge.The top will be 18+1 mm thk and supported by fixed legs and having adjustable leveling screws.
The work should be executed as per detailed Technical Specification and direction of the Engineer in charge of this work
1
-
-
... More
Providing and fixing Slotted Angle Storage Racks: Providing and installing flexible storage racks with slots to fix the shelves in different positions, made in powder coated CRCA MS Sheets of 0.80 mm Thickness. Powder coating shall be of approved colour and 45-50 microns thickness and shall pass through a salt spray test of 1000 hours and have a minimum scratch hardness of 3 Kgs. The unit shall be mounted on leveling screws to accomodate any variations/ undulations in the finished floor.The work should be executed as per detailed Technical Specification and direction of the Engineer in charge of this work
2
-
-
... More
Providing and fixing Peninsular island Bench of total length= 1549mm Height =914mm and Depth 1219mm with PP powder quoted (110 microns) cabinets and adjustable PVC levellers to correct unevenness of the floor.
The work should be executed as per detailed Technical Specification and direction of the Engineer in charge of this work
2
-
-
... More
Supplying and commissioning of Bench Fume Hood in locations as indicated in the drawing and as specified in attached document all necessary water inlet, waste outlet, power sockets, gas connections, compressed air connections etc.,complete as per attached detailed specifications Size of 48W x 39D x 90H- Each Unit shall consist of:
Bench FH Structure Combination Sash 48W 39D 55H - 1 No
Bench FH Base 48W 35H 2S - 1 No
BFH Rear Support 4 Ft 11D - 1 No
FH 6/16A Socket & Switch 3M Single Phase - 3 No
FH Wire Manager - 1 No
FH Led Lighting Fixture - 1 No
FH Tube Light On-Off Rocker Switch - 1 No
Drip Cup-PP Oval With Drain Pipe - 1 No
FH Raw Water - 90 Spout & Hoses 1-1.5 Mt - 1 No
FH Nitrogen - 45 Spout & Hoses 1-1.5 Mt - 1 No
FH Compressed Air - 45 Spout & Hoses 1-1.5 Mt - 1 No
FH No-Nc Switch - 1 No
FH Taper Cone Adaptor (Metal) - 1 No
4Ft FH Granite Work Surface 39D - 1 No
FH Manual Butter Fly Valves - 1 No
FH Ceiling Enclosure 48W 39D 21H Front Access - 1 No
The work should be executed as per detailed Technical Specification and direction of the Engineer in charge of this work
6
-
-
... More
Providing and fixing Static Pass Box fabricated with powder coated 304 grade stainless steel With UV light along with hour meter, Fluorescent light, buzzer and indicator lamps, solid door w/ mechanical interlocked, tempered glass window,etc complete Inner Size 450W x450D x450H
The work should be executed as per detailed Technical Specification and direction of the Engineer in charge of this work
5
-
-
... More
Providing and installing of Emergency Safety Shower With Eye Wash Floor Mounted showers in the locations indicated in the drawings and as per following specifications:The work should be executed as per detailed
Inlet Pipe: SS #304, 1.25" diameter Outlet Pipe: SS # 304, 1.25" diameter
Emergency Shower Inlet Pipe: SS #304, 0.75" diameter
Switch & Pull Rod: Fixed pull-over switch
Shower Bowl: external bowl of outside use SS #304, with polishing finish on the top surface. Shower Head: more than 800 holes, rain shower type.
Eye Washer: Inlet Pipe: SS #304, 0.50" diameter
Control: Manual Switch, foot pedal type.
Eye Wash: outside use SS #304, with polishing finish on top surface.
Eye Wash Faucet: Cast by non-burnable polycarbonate, with filter sponge and cover that can avoid dust, to be openable by water pressure directly to avoid contamination.
Size Total Height: 2325 mm ± 15 mm/ Emergency Shower: 2100 mm ± 20 mm / Eye Wash: 1030mm ± 20 mm
Accessories: Bulletin board of SS #304, Drawing to indicate method of use and adequate number of expandable screws for fixing the same.
Water Pressure: The piping of the emergency system should be capable of bearing water pressure of 18 kg/cm2 (250 psi).
Technical Specification and direction of the Engineer in charge of this work
6
-
-
... More
4" Dia Drain PVC Pipe for all floor with Accessories and hardware.
The work should be executed as per detailed Technical Specification and direction of the Engineer in charge of this work
35
-
-
... More
Providing and fixing 1" CPVC water inlet with Accessories and hardware
The work should be executed as per detailed Technical Specification and direction of the Engineer in charge of this work
20
-
-
... More
KSRB13-6.6-4 : Providing and fixing unplasticised PVC connection pipe with brass union 20mm nominal bore 450 mm length of PVC connection including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. Specification No.KBS Technical Specification and direction of the Engineer in charge of this work
Page no 94 Item No 13.49
25
-
-
... More
KSRB13-6.3-2 : Providing and fixing in position brass gate valve with C.I wheel of approved quality ( screwed end ) 20mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. Specification No.KBS 13.2.6 / 13.3
The work should be executed as per detailed Technical Specification and direction of the Engineer in charge of this work
Page no 93 Item No 13.33
25
-
-
... More
Providing and fixing Base A 16D 30W 2S 0D
The work should be executed as per detailed Technical Specification and direction of the Engineer in charge of this work
1
-
-
... More
Providing and fixing Base A 16D 21W 1S RHS 0D
The work should be executed as per detailed Technical Specification and direction of the Engineer in charge of this work
1
-
-
... More
Providing and fixing Leg Space 30" x 22" D x 36"H
The work should be executed as per detailed Technical Specification and direction of the Engineer in charge of this work
19
-
-
... More
Providing and fixing Leg Space 24" x 22" D x 36"H
The work should be executed as per detailed Technical Specification and direction of the Engineer in charge of this work
22
-
-
... More
Providing and fixing Back Cover Panel, End Cover Panel, Front Filler Panel, Panel Leg & support panel For Cabinets & Leg space
The work should be executed as per detailed Technical Specification and direction of the Engineer in charge of this work
1
-
-
... More
Providing Stool with Half Back Rest
The work should be executed as per detailed Technical Specification and direction of the Engineer in charge of this work
15
-
-
... More
Providing and fixing Electric raceway 5" H X 5" D
The work should be executed as per detailed Technical Specification and direction of the Engineer in charge of this work
114.9
-
-
... More
BLOWER & DUCTING Providing and fixing PP Blower 1.0 HP with DOL Starter & Stand
The work should be executed as per detailed Technical Specification and direction of the Engineer in charge of this work
5
-
-
... More
Blower For 2 Nos. 4 Ft. Fume hoods (Sample preparation-1& Sample preparation-2)
Providing and fixing PP+FRP Ducting Material The work should be executed as per detailed Technical Specification and direction of the Engineer in charge of this work
80
-
-
... More
Open Conduit System: Supplying heavy guage PVC conduit pipe 19mm dia confirming to IS:2509 with suitable size bends, junction boxes, adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy guage saddles at an intervel of 700mm using WF screws. a) 25mm dia 2mm thick
The work should be executed as per detailed Technical Specification and direction of the Engineer in charge of this work
Page No 2 Item No 1.1.2
75
-
-
... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multisand Copper with low conductor resistance single core wire in open or consealed system of wiring with specified IS-694:1990 & confirming to GTP of Group-A. 1.5sqmm
The work should be executed as per detailed Technical Specification and direction of the Engineer in charge of this work
Page No 6 Item No 2.5.2
290
-
-
... More
Same as above but for 2.5sqmm
The work should be executed as per detailed Technical Specification and direction of the Engineer in charge of this work
Page No 6 Item No 2.5.3
150
-
-
... More
Same as above but for 4.0sqmm
The work should be executed as per detailed Technical Specification and direction of the Engineer in charge of this work
Page No 6 Item No 2.5.4
200
-
-
... More
Supplying and fixing of modular switch/socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293
Group 'A' Material
16Amps one way switch
Page No 16 Item No 3.7.7
59
-
-
... More
6/16Amps universal socket
The work should be executed as per detailed Technical Specification and direction of the Engineer in charge of this work Page No 16 Item No 3.7.10
192
-
-
... More
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required. confirming to IEC 60898.
a)5-32A SP MCB
The work should be executed as per detailed Technical Specification and direction of the Engineer in charge of this work
Page No 47 Item No 6.16.1
100
-
-
... More
Wall bores in Brick masonry upto 45 cm thick.
Page No 269 Item No 37.35
20
-
-
... More
TOTAL FOR ALL WORKS
-
-
-