Karnataka State Police Housing And Infrastructure Development Corporation Limited Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Karnataka State Police Housing And Infrastructure Development Corporation Limited - KSPHCL Tender

Building Construction
Opening Date27 Sep 2021
Closing Date16 Oct 2021
Tender Amount₹ 4,96,69,428 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. - 25mm dia 2mm thick ---- as per directions of engineer incharge of work.

300

-

16200

... More
Supplying And Fixing Metal Fan Box with Round Hook. ---- as per directions of engineer incharge of work.

45

-

3825

... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.The following additional tests are compulsory either to be conducted at works or independent lab with witness by inspecting authority.Additional Tests for FRLS-Applicable Standard Oxygen Index -IS 694-1990, Clause 16.8 Temperature Index -IS 694-1990, Clause 16.13 Smoke Density -IS 694-1990, Clause 16.14 Test for Halogen Acid Gas evaluation -IS 694-1990, Clause 16.12 - 4 sqmm ---- as per directions of engineer incharge of work.

1600

-

72000

... More
Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. - Short point upto 3Mtr from tapping point to out let via switch box ---- as per directions of engineer incharge of work.

48

-

7680

... More
Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. - Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box ---- as per directions of engineer incharge of work.

60

-

15000

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 4 Module ---- as per directions of engineer incharge of work.

15

-

1875

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 6 Module ---- as per directions of engineer incharge of work.

12

-

2100

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 8 Module ---- as per directions of engineer incharge of work.

30

-

6000

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 10-12 Module ---- as per directions of engineer incharge of work.

30

-

6900

... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.The following additional tests are compulsory either to be conducted at works or independent lab with witness by inspecting authority.Additional Tests for FRLS-Applicable Standard Oxygen Index -IS 694-1990, Clause 16.8 Temperature Index -IS 694-1990, Clause 16.13 Smoke Density -IS 694-1990, Clause 16.14 Test for Halogen Acid Gas evaluation -IS 694-1990, Clause 16.12 - 1.5 sqmm ---- as per directions of engineer incharge of work.

2500

-

51250

... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.The following additional tests are compulsory either to be conducted at works or independent lab with witness by inspecting authority.Additional Tests for FRLS-Applicable Standard Oxygen Index -IS 694-1990, Clause 16.8 Temperature Index -IS 694-1990, Clause 16.13 Smoke Density -IS 694-1990, Clause 16.14 Test for Halogen Acid Gas evaluation -IS 694-1990, Clause 16.12 - 2.5 sqmm ---- as per directions of engineer incharge of work.

3500

-

112000

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 1-3Way ---- as per directions of engineer incharge of work.

60

-

5700

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 4-5Way ---- as per directions of engineer incharge of work.

15

-

1575

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 6Way ---- as per directions of engineer incharge of work.

12

-

1500

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 8Way ---- as per directions of engineer incharge of work.

30

-

4350

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 10-12Way ---- as per directions of engineer incharge of work.

20

-

3300

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 1 to 3 Module ---- as per directions of engineer incharge of work.

60

-

6600

... More
Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. - Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box ---- as per directions of engineer incharge of work.

85

-

31875

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. - TV/Telephone socket ---- as per directions of engineer incharge of work.

6

-

474

... More
Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. - Musical ---- as per directions of engineer incharge of work.

6

-

2364

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. - 6Amps one way Switch ---- as per directions of engineer incharge of work.

230

-

16100

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. - 16Amps one way switch ---- as per directions of engineer incharge of work.

20

-

2300

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. - 6Amps 3way socket ---- as per directions of engineer incharge of work.

220

-

23100

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. - 6/16Amps universal socket ---- as per directions of engineer incharge of work.

8

-

1296

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. - Stepped Fan Regulator. ---- as per directions of engineer incharge of work.

36

-

10440

... More
Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. - 48" Sweep (1200mm) Regular model ---- as per directions of engineer incharge of work.

36

-

75240

... More
Supplying wall mounting fan suitable to operate at single- phase 230v AC. supply. - 300mm Sweep ---- as per directions of engineer incharge of work.

24

-

62400

... More
Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ---- as per directions of engineer incharge of work.

60

-

9000

... More
Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI > 80. Power Input: 220-240V@ 50/60Hz & Power factor >0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. - LED light fitting 1 x 4'- 20/22 w ---- as per directions of engineer incharge of work.

90

-

33750

... More
Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI> 70%. efficacy > 100 lumen per watt, 120degree beam spread, life> 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF > 0.95, power loss should< 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. - LED modular down light 2'x2' /1' X 4' 34 -36watt ---- as per directions of engineer incharge of work.

34

-

176800

... More
Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps. - On wall/ ceiling / Rafter / Girders ---- as per directions of engineer incharge of work.

124

-

13640

... More
LED Down light :Supplying of recess mounting non integrated type LED down light...... W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRI> 70%. efficacy >100 lumen per watt, 120degree beam spread, life> 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF > 0.95, power loss should< 5% of lamp wattage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. - 15-18W ---- as per directions of engineer incharge of work.

40

-

80000

... More
Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6. ---- as per directions of engineer incharge of work.

60

-

2100

... More
LED Post Top Lantern GARDEN.: Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light output. Rated life Burning Hrs 50000 hr@ Lumen Maintenance of 70%, CCT > 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire > IK08. Power Factor>0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB LED Efficiency>130 lm/w, nominal CRI >75. Luminaire manufacturer should have in- house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. - LED Post Top Lantern with 25 watts ---- as per directions of engineer incharge of work.

4

-

22400

... More
Fixing charges of post top/ Gate/ Garden fitting /LED on the existing CI/ GI or any other pipe using required size of reducer, wiring using suitable wires. ---- as per directions of engineer incharge of work.

4

-

616

... More
LED Street light : .Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT > 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire > IK08. Power Factor >0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency>1301m/w, nominal CRI >75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. - LED Streetlight 70 Watts ---- as per directions of engineer incharge of work.

6

-

32880

... More
Supplying and Fixing of........mm dia class A GI pipe bracket up to 2 Mtrs long bent at suitable angle and fixing to this bracket 1x40/2x40 watts fluorescent tube street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires. - Using 32mm dia G.I.Pipe ---- as per directions of engineer incharge of work.

6

-

5010

... More
Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- as per directions of engineer incharge of work.

14

-

16800

... More
Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 amps. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. ---- as per directions of engineer incharge of work.

14

-

5600

... More
Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc. complete.(As per Civil SR KSRB 1-2, P-7) - In soil (ordinary) ---- as per directions of engineer incharge of work.

150

-

11400

... More
Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1KV - 40mm ---- as per directions of engineer incharge of work.

10

-

3350

... More
Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. - 16SWG ---- as per directions of engineer incharge of work.

130000

-

45500

... More
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. - 40x40x6mm ---- as per directions of engineer incharge of work.

8

-

2040

... More
Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. - 250Amps 4x30x10mm Aluminium Strips ---- as per directions of engineer incharge of work.

2

-

5700

... More
Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 - 3.5 core 70 sqmm ---- as per directions of engineer incharge of work.

120

-

42000

... More
Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe/ stoneware pipe /on wall / on pole as required. In existing trench/duct. On wall/Structure - 25 sqmm to 75 sqmm ---- as per directions of engineer incharge of work.

120

-

1860

... More
Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 - 4 core 16 sqmm ---- as per directions of engineer incharge of work.

80

-

12000

... More
Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe/ stoneware pipe /on wall / on pole as required. In existing trench/duct. On wall/Structure - 6 sqmm to 16 sqmm ---- as per directions of engineer incharge of work.

80

-

950.4

... More
Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 - 4 core 10 sqmm ---- as per directions of engineer incharge of work.

60

-

7800

... More
Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe/ stoneware pipe /on wall / on pole as required. In existing trench/duct. On wall/Structure - 6 sqmm to 16 sqmm ---- as per directions of engineer incharge of work.

60

-

712.8

... More
Supplying and fixing LT cast Iron pot heads suitable for 1.1KV class UG cable filled with necessary bitumen/insulating compound complete with terminals, clamps, bolts, nuts and washers etc. - 70Sqmm ---- as per directions of engineer incharge of work.

2

-

1244

... More
Supplying and fixing LT cast Iron pot heads suitable for 1.1KV class UG cable filled with necessary bitumen/insulating compound complete with terminals, clamps, bolts, nuts and washers etc. - 35Sqmm ---- as per directions of engineer incharge of work.

2

-

700

... More
Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia ---- as per directions of engineer incharge of work.

4

-

11998.8

... More
Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. ---- as per directions of engineer incharge of work.

6

-

24900

... More
Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. - 25x3mm GI strip ---- as per directions of engineer incharge of work.

25

-

1875

... More
Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. - 600x600x3mm Copper plate ---- as per directions of engineer incharge of work.

3

-

20700

... More
Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 - 3.5 core 35 sqmm ---- as per directions of engineer incharge of work.

80

-

18000

... More
Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe/ stoneware pipe /on wall / on pole as required. In existing trench/duct. On wall/Structure - 25 sqmm to 75 sqmm ---- as per directions of engineer incharge of work.

80

-

1240

... More
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (Icu=lcs) THREE POLE FOUR POLE - 200Amps 35kA ---- as per directions of engineer incharge of work.

1

-

16100

... More
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (Icu=lcs) THREE POLE FOUR POLE - 100Amps 25kA ---- as per directions of engineer incharge of work.

9

-

57600

... More
Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. (Open Execution) - 200Amps ---- as per directions of engineer incharge of work.

2

-

21000

... More
Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 1- Single Door II -Double Door Ill -Double Door - 8Way SP &N ---- as per directions of engineer incharge of work.

6

-

8700

... More
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - 6-32Amps SP ---- as per directions of engineer incharge of work.

28

-

12152

... More
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - 6-32Amps DP ---- as per directions of engineer incharge of work.

8

-

7272

... More
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - 6-32Amps TPN ---- as per directions of engineer incharge of work.

4

-

6860

... More
Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V up to 300mA sensitivity on existing wood/panel board. - 32-40 Amps 4 pole ---- as per directions of engineer incharge of work.

6

-

16800

... More
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. ---- as per directions of engineer incharge of work.

6

-

2580

... More
Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter ---- as per directions of engineer incharge of work.

4

-

4740

... More
Supplying of .. TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 Volts with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit. - 2 ton capacity 5 star ---- as per directions of engineer incharge of work.

10

-

660000

... More
Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support up to 3.0 ton split/cassette type A/C. ---- as per directions of engineer incharge of work.

10

-

29000

... More
Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tube. - Split ---- as per directions of engineer incharge of work.

80

-

92400

... More
Supplying, erecting, testing and commissioning of voltage stabilizer suitable for 170 to 270 V input and load variation from no load to full load, with over load protection, spike suppression, operating at 00 C to 400 C. Range etc., complete. - 3KVA Capacity ---- as per directions of engineer incharge of work.

10

-

38400

... More
Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm - Using 6ft. Copper bonded rod with backfill compound ---- as per directions of engineer incharge of work.

3

-

15975

... More
Supplying and drawing UTP-CAT 6E LAN cable. ---- as per directions of engineer incharge of work.

2400

-

69600

... More
Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. - 2Pair ---- as per directions of engineer incharge of work.

600

-

8700

... More
Supplying & Fixing of Patch panel for LAN cabling - 24 Port 10/100/1000 patch panel ---- as per directions of engineer incharge of work.

4

-

28000

... More
Supplying fixing of Network Switches - 24 port 10/100 Switch ---- as per directions of engineer incharge of work.

4

-

16000

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. - RJ45/I.O.outlet Cat-6 ---- as per directions of engineer incharge of work.

120

-

23400

... More
Supplying & Fixing of switch mounting rack with power manager & Cable manager. - 12U with 450mm depth ---- as per directions of engineer incharge of work.

2

-

15200

... More
Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 volts 1/3 phase motor upto 5 HP. ---- as per directions of engineer incharge of work.

2

-

2760

... More
Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. - 32Amps ---- as per directions of engineer incharge of work.

6

-

1044

... More
HT Cable: Supplying and laying of high tension 11KV cable, Dry Curing & Dry Cooling with true triple extrusion, simultaneously through a single common head, 3 core under ground XLPE (E) cable having stranded compact circular aluminium conductor, screened insulated, insulation screened with extruded semiconducting compound in combination with copper tape, core laid up extruded inner sheathed of GI flat strip armoured and overall PVC sheathed with specified IS 7098/11/85 with latest amendments. - 3Cx95sqmm ---- as per directions of engineer incharge of work.

90

-

93600

... More
Supplying and making 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations- INDOOR & OUTDOOR JOINTING KIT latest amendments. - 3Cx95/120sqmm OUTDOOR ---- as per directions of engineer incharge of work.

4

-

39420

... More
Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations- STRAIGHT THROUGH JOINTING KIT. - 3Cx95/120Sqmm ---- as per directions of engineer incharge of work.

2

-

36974

... More
Supply, erection, testing and commissioning of ..................KVA 5Star rated Aluminium/Copper wound Distribution Transformer 11 KV/433Vwith Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, marshalling box with wiring, oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Bushing Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved. - 63 KVA- Aluminium Wound ---- as per directions of engineer incharge of work.

1

-

147408

... More
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. - 40x40x6mm ---- as per directions of engineer incharge of work.

15

-

3825

... More
LT Distribution Box for 63/100 KVA Transformer with 1 No 160Amps 25kA 4Pole MCCB, suitable capacity Aluminium bus bar mounted in 16SWG powder coated M.S.Box suitable to mount at Transformer Centre as per ESCOM. ---- as per directions of engineer incharge of work.

1

-

16479.1

... More
Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. - 5 KVA ON LINE UPS ---- as per directions of engineer incharge of work.

2

-

148500

... More
Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries. ---- as per directions of engineer incharge of work.

2

-

4430

... More
Supplying, installing, testing and commissioning of Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514/ISO 3046/ ISO 8528 & IS 1002/ISO 3046 Generator set specifications. Engine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade), Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation Alternator: Alternator is suitable for operation at 1500 RPM, 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming to IS/IEC 60034-1. The Alternator is brush less type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have± 1.0% Voltage regulation (max) in static conditions- IP: 23 protections with insulation class F&H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for 'Load On' and 'Set Running', Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections.Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,-Auto start mode accepts a ground signal from remote devices to automatically start the DG set The remote start will also wake up the control system from sleep mode. Engine Starting -The control system supports automatic engine starting, Primary and back up start disconnects are achieved by battery charging alternator feedback or main alternator output frequency. Controller provide configurable time delay of 0-300 sees to start after remote start signal and time delay of 0-600secs prior to shut down after stop signal. Sleep mode increase battery life. Configurable current settings from low to minimize current draw when genset is not working. Engine Protective functions include, Configurable alarm output, Emergency stop: Annunciated whenever an emergency stop signal is received by the control. Low lube oil pressure warning and Shutdown, High engine water temp warning / Shutdown, Low coolant temp warning, Sensor failure indication, Low and high battery voltage warning, Weak battery warning, Fail to start shut down, Cracking lockout: Control will not allow the starter to engage or to crank the running engine Cyclic cranking: Configurable for the number of starting cycle, (1 to 7) and duration of crank and rest periods. Alternator Protective functions includes, - High and Low AC voltage shut down, Under and Over frequency shutdown / warning, Loss of sensing voltage input shut down. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest The enclosure has the following features: Specially designed to meet stringent MOEF/CPCB norms of 75dBA @ 1mtr at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at rated load made on special purpose CNC machines for consistency in quality and workmanship, Powder coated for long lasting service life and superior finish, With UV resistant powder coating, can withstand extreme environment, Use of special hardware for longer life, Insulation material meets exacting IS 8183 specifications for better sound attenuation, Flush styling - no projections, Fluid drains for lube oil and fuel, Fuel filling point inside the enclosure. The complete set shall have sufficient safety and adhere to NEC, NBC 2016, IEC, CPWD specifications, PCB norms and KSGEI Acts and Rules. - 62.5 KVA/50kw ---- as per directions of engineer incharge of work.

1

-

514500

... More
Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990. - 3C X 4.0Sq.mm ---- as per directions of engineer incharge of work.

480

-

67200

... More
Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. - 75/80 AH capacity ---- as per directions of engineer incharge of work.

12

-

104400

... More
Supply, Erection, testing and commissioning of AMF panel suitable for .....KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .....amps 4 pole contactor for alternator with thermal O/L relay,..... Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, ....capacity bypass switch and frequency sensing, PCC 1301controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMF module by pass Mode, Battery charger unit with inbuilt Auto/Manual and Flat/Boost facility. The complete set shall have sufficient safety and adhere to NEC, NBC 2016, IEC, CPWD specifications, PCB norms and KSGEI Acts and Rules. - Above 50 KVA upto 62.50 KVA ---- as per directions of engineer incharge of work.

1

-

89500

... More
8-9 Watts ---- as per directions of engineer incharge of work.

20

-

7000

... More
Supplying and fixing cast Aluminium round or oblong type bulk head fitting with GI wire guard, glass cover with 60/100 watts 230 volts GLS lamp as required. as per the directions of the engineer in charge of the work ---- as per directions of engineer incharge of work.

6

-

4482

... More
Supplying and fixing PBBC bakelite straight or slant batten holder and wiring, within 60w/230 volts lamps. Materials and as per the directions of engineer in charge of the work. . ---- as per directions of engineer incharge of work.

40

-

3520

... More
Supply and laying double walled corrugated (DWC) HDPE Pipe including all necessary connecting Sockets/Couplings/Tees/Bends/End-caps of same materials in exisiting trench as per IS 14930 part -II suitable for drawing under ground cables.( 63 / 7.20)c) 63mm OD / 50mm ID as per the directions of the engineer in charge of the work ---- as per directions of engineer incharge of work.

20

-

4120

... More
Supplying of FIRST AID CHART with lamination. complete and as per the directions of engineer in charge of the work. ---- as per directions of engineer incharge of work.

1

-

201

... More
Supplying and installation of RUBBER MAT 1mtr x 1mtr -10mm thick. complete including cost of materials, labour, HOM complete as per specifications as per the directions of engineer in charge of the work. ---- as per directions of engineer incharge of work.

1

-

987

... More
Supply of erection testing and commissioning of RO purifier water filter and connected accessoriers etc. as per the directions of the engineer in charge of the work ---- as per directions of engineer incharge of work.

2

-

90000

... More
Supply of erection testing and commissioning of water level controller and connected accessoriers etc. as per the directions of the engineer in charge of the work ---- as per directions of engineer incharge of work.

4

-

16000

... More
"Supplying , fixing & wiring of Open well Mono Sub pump set 3 HP suitable for operation on 440 volts 2800 RPM Three phase AC supply after aligning, leveling & assembling etc, inclusive of transportation charges to work spot, as per the directions of engineer incharge of the work. " ---- as per directions of engineer incharge of work.

2

-

39218

... More
Fixing charges of pumpset after aligning, leveling & assembling etc, inclusive of transportation charges to work spot as per the directions of engineer incharge of the work. ---- as per directions of engineer incharge of work.

2

-

1000

... More
"Supplying of 50 mm kirloskar / other approved make CI screwed foot valve. Make- Using group ""A"" materials. And as per the directions of engineer incharge of the work. " ---- as per directions of engineer incharge of work.

1

-

450

... More
Supplying and Delivery at Site 7.5 HP / 5.5 KW, 23 Stage Submersible Pump set of approved make ISI with Motor. Suitable for operation of 3 Phase 50 HZ 440 Volts A.C supply fitted with required accessories complete and as per the directions of Engineer in charge of the work. ---- as per directions of engineer incharge of work.

1

-

43574

... More
KSRB13-6.3 : Providing and fixing in position brass gate valve with C.I wheel of approved quality ( screwed end ) 50 mm nominal bore including cost of all materials, labour and HOM with all leads complete as per specifications. Specification No.KBS 13.2.6 / 13.3 KSRB13-6.3-6 - do - 50 mm dia nominal and as per the directions of Engineer in charge of the work. ---- as per directions of engineer incharge of work.

1

-

1739

... More
KSRB13-7.1 : Providing and fixing in position nominal bore gun metal non-return valve horizontal type of approved make including cost of all materials, labour and HOM with all leads complete as per specifications. Specification No.KBS 13.2.10 / 13.13 KSRB13-7.1-4 - do - 50 mm dia nominal bore and as per the directions of Engineer in charge of the work. ---- as per directions of engineer incharge of work.

1

-

1330

... More
Out door type control panel Borad : Supplyinbg and Delivery Site brand new best indigenous make combined energy meter cum control panel borad of size 1200*600*350mm suitable for aperation on 3 Phase Hz 440 Volts meter, ammeter, single phase preventor etc conplete set Make - Group "A" materials and as per the directions of Engineer in charge of the work. Upto 10 HP ---- as per directions of engineer incharge of work.

1

-

10500

... More
Erection of panel and Meter Borad : Erection of combined panel borad and meter borad unit with necessary materials and labour charges Inculuding providing cement concrete foundation bed ect complete. as per the directions of the engineer in charge of the work. ---- as per directions of engineer incharge of work.

1

-

369

... More
Erection, Electrification and commissioning Work of Pump Sets : eraction of pumpset including aligning and balancing with all necessary erection materials and labour including supply and erection of two pair of supporting clamps, bore-well, cap, cable protector bolts, nuts, valve and gauges ect., as per the directions of the engineer in charge of the work. ---- as per directions of engineer incharge of work.

1

-

1478

... More
"Providing and fixing in trenches galvanised/ mildsteel tubes 50mm dia nominal bore with all fittings including cost of all materials and labour charges and HOM of equipments and testing complete as per specifications Make - Group ""A"" materials and as per the directions of Engineer in charge of the work. " ---- as per directions of engineer incharge of work.

230

-

117760

... More
"Pre - Stressed Tubular Spun Pole 11 Mtr Long - 500Kg WL (Dwg No. BESCOM/GM/QS&S/45 Dtd 24.11.2018) as per IS-13158:1991 " as per the directions of the engineer in charge of the work ---- as per directions of engineer incharge of work.

1

-

16850

... More
KSRB 5.3-3 : Providing and constructing granite / trap / basalt size stone masonry in basement with cement mortar 1:6, edges of stones chistle dressed in courses not less than 15 cms high, bond stones at 2m. apart in each course including cost of materials, labour, curing complete as per specifications. KBS 5.1.13 as per the directions of the engineer in charge of the work ---- as per directions of engineer incharge of work.

1

-

5483

... More
"Single Pole Mounted Transformer Kit for erection of Transformers on 11 Mtr Spun Poles as per IS-1977.Three H Frame with Transformer Seating and Seating angle support X arm for 11 mtr Spun Pole for 25/63/100 kVA (UG Cable) - MS as per the directions of the engineer in charge of the work. " ---- as per directions of engineer incharge of work.

1

-

26734

... More
GOS as per IS-9921, IS-1977 : 11kV, 200 Amps Single Break GOS (Dwg No.BESCOM/GM/QS&S/23 Dtd 24.11.2018) as per the directions of the engineer in charge of the work. ---- as per directions of engineer incharge of work.

2

-

15598

... More
Providing cement concrete to poles and Guy sets with material and labour including necessary curing etc., complete (cost does not include excavation) c) Pole base 11mtr spun pole (1000x1000x150mm) as per the directions of the engineer in charge of the work. ---- as per directions of engineer incharge of work.

3

-

2190

... More
"Supplying and fixing M.S. Rectangular poles made out of 2 equal angles of 65x65x6 mm welded together and fixed in CC (1:2:4) WITH 2 NOS 16mm dia M.S. hold fast rods each of length 25 cms. Including cost of all materials cutting, bending scaffolding wherever necessary, nicely finishing the welded joints with all lead lifts and as per the directions of the Engineer-in - charge of the work and including providing 2 coats of approved quality paint over one coat of shop painting ( excluding cost of earthwork and concrete) including cost of materials, labour, HOM complete as per specifications."as per the directions of the engineer in charge of the work ---- as per directions of engineer incharge of work.

30

-

25770

... More
"Providing chain link fencing 50mm size of 8 guage properly stretched between existing rectangular poles and fixed with suitable bolts & nuts, the free ends shall be welded to the pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts and as per the directions of the Engineer-in-charge of work including two coats of approved quality paint over one coat of shop paint, including cost of materials, labour, HOM complete as per specifications." as per the directions of the engineer in charge of the work ---- as per directions of engineer incharge of work.

30

-

21450

... More
Providing and spreading jelly/ Aggregate 40mm size for transformer yard--(15'x20'--150mm) etc complete as per directions of engineer in charge of the work ---- as per directions of engineer incharge of work.

3

-

3274.29

... More
LT Metering Box for housing the ETV Meters without CT's busbar wiring as per the directions of the engineer in charge of the work. ---- as per directions of engineer incharge of work.

1

-

3664

... More
Modem charges as per the directions of the engineer in charge of the work. ---- as per directions of engineer incharge of work.

1

-

18000

... More
LT Electronic Tri - Vector Meter 5A, Class-0.5 accuracy as per the directions of the engineer in charge of the work. ---- as per directions of engineer incharge of work.

1

-

2061

... More
Supplying and fixing EPABX system 3 Analog Trunk and 8 Analog system etc complete as per the directions of engineer in charge of the work. ---- as per directions of engineer incharge of work.

2

-

56360

... More
Supplying telephones KX -AT7730SX/SXB as per the directions of engineer in charge of the work. ---- as per directions of engineer incharge of work.

4

-

16992

... More
Supplying, Installation & commissioning telephones Anolog basic as per the directions of engineer in charge of the work. ---- as per directions of engineer incharge of work.

12

-

8352

... More
Design, supplying, erecting, testing and commissioning of 8 passenger 5 stops With out Machine Room-SS Finish / Bed-cum-passenger hospital lift with speed of 1.5 mtr per second, variable voltage variable frequency drive, without machine room for the available well sizeoperating at 415 V 3 phase 50 (Hz) cycles AC supply, powder coated / Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED car illumination, emergency light, intercom and fan as desired by the user, central opening door with or without attendant operation, 7 segment display buttons, call register indicator, fireman drive, SS handrails inside car, full length infrared curtain in car door, automatic rescue device with batteries, voice announcing in regional / international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc., The total product and services shall adhere to IS 14665/2016 (with latest amendments) part/section 1 to 5 with regards to general guidelines of fire safety rated doors, MRLL beams, pressure switch, manual change over for doors during emergency, ARD of 10 times with sufficient battery back up and standard dimensions of chair car and door openings for all sizes and capacities of lifts including fitness certificate and duly observing all other safety norms prescribed and adhere to CPWD specifications, PCB Norms, National Electricity Code (NEC), NBC-2016, IEC and Karnataka State Lifts, Escalators and Passengers Conveyers Act 2012 and Rules 2014. The supplier shall be registered in Government Electrical Inspectorate in the State of Karnataka, as per the directions of engineer in charge of the wo ---- as per directions of engineer incharge of work.

1

-

1348300

... More
Supplying & fixing Lift panel with required MCB's, ELCB and wiring etc complete set, as per the requirement of lift vendor as per the directions of the engineer in charge of the work ---- as per directions of engineer incharge of work.

1

-

16479.1

... More
DG set/Exhaust foundation 3x2x1.5 mtr for 62.5 KVA DG set as per direction of engineer incharge of the work. ---- as per directions of engineer incharge of work.

1

-

29411.76

... More
Exhaust System : Supply, receive at site, store, unpack, assemble and connect exhaust pipe with Class B MS pipe with flanges, fire fly gaskets, hardware, glass wool and aluminium sheet cladding etc., as per specification inclusive of all structural supports etc., complete as required. Individual Exhaust pipe including flexibles from set with glass wool and Alu. clading etc., as required complete for 62.5 KVA DG set (diameter of the pipe shall be specified by the vendor) as per BESCOM norms.as per direction of engineer incharge of the work. ---- as per directions of engineer incharge of work.

10

-

24000

... More
Silencer with painting glass wool insulation / Al. clading etc., as required complete for 62.5 KVA DG set as per direction of engineer incharge of the work. ---- as per directions of engineer incharge of work.

1

-

2899.2

... More
" PVC insulated, steel armoured 1100 V Grade Copper Conductor cables. c) 12C x 2.5 sq.mm (YFY). as per direction of engineer incharge of the work." ---- as per directions of engineer incharge of work.

25

-

10800

... More
Supplying of OFC cable 12 core with armoured as per direction of engineer incharge of the work. ---- as per directions of engineer incharge of work.

30

-

7500



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.