Karnataka State Police Housing And Infrastructure Development Corporation Limited Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Karnataka State Police Housing And Infrastructure Development Corporation Limited - KSPHCL Tender

Opening Date15 Dec 2021
Closing Date24 Dec 2021
Tender Amount₹ 2,05,03,905 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
KSRB 2-2.4 : Excavation by manual means for foundation of buildings, water supply & sanitary lines and electrical conduits etc. , either in pits or in trenches 1.50m and above in width, in soft rock /ordinary rock without blasting not exceeding 1.50mtrs in depth including stacking the excavated stuff clear from edges of excavation with lead upto 50mt including cost of explosives, labour, HOM complete as per specifications. specification. No. KBS 2.1Cl2.9.412.1812.19 ---- as per directions of engineer in-charge of work.

87.719

-

132127.62

... More
KSRB 4-1.3 : Providing and laying in position plain cement concrete of mix 1:4:8 with OPC cement @ 180kgs, with 40mm and down size graded granite metal coarse aggregates @0.85cum and fine aggregates @ 0.57cum machine mixed, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, including cost of all materials, labour, HOM of machinery, curing complete as per specifications. Specification No. KBS 4.1, 4.2 ---- as per directions of engineer in-charge of work.

61.5258

-

344465.11

... More
KSRB 4.2.2 : Providing and laying in position reinforced cement concrete of Design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregtes @ 0.460 cum, with super plasticisers @ 3 liters confirming to is 9103-1999 reafirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in foundation for footings, pedastals, retaining walls, return walls, walls (any thickness) including attached pilasters, columnspillars, posts, struts, buttresses, bed blocks, anchor blocks & plinths etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 ---- as per directions of engineer in-charge of work.

9.737

-

58923.84

... More
KSRB 4-6.1 : Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for foundations, footings, bases of columns for mass concrete including cost of all materials, labour complete as per specificaitons. Specification No. KBS 4.6.2 ---- as per directions of engineer in-charge of work.

38.058

-

10287.08

... More
KSRB 4.2.8: Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in ground floor level for roof slabs, staircase, lintles, and beams retaining walls, return walls, walls (any thickness) including attached plasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 ---- as per directions of engineer in-charge of work.

20.6693

-

130186

... More
KSRB 4.2.8: Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in ground floor level for roof slabs, staircase, lintles, and beams retaining walls, return walls, walls (any thickness) including attached plasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 ---- as per directions of engineer in-charge of work.

5.124

-

32599.5

... More
KSRB 4-6.5 : Providing and removing centering, shuttering, strutting, propping etc., for columns, pillars, post and struts, square / rectangular/ polygon in plan including cost of all materials, labour complete as per specifications. Specification No. KBS 4.6.2 ---- as per directions of engineer in-charge of work.

254.0884

-

122816.17

... More
KSRB 4-6.5 : Providing and removing centering, shuttering, strutting, propping etc., for columns, pillars, post and struts, square / rectangular/ polygon in plan including cost of all materials, labour complete as per specifications. Specification No. KBS 4.6.2 ---- as per directions of engineer in-charge of work.

67.32

-

32539.8

... More
KSRB 5.1-3 : Providing and constructing granite / trap / basalt rubble stone masonry in foundation with cement mortar 1:6 (uncoursed), bond stones at two m. apart in each course including cost of materials, labour, curing complete as per specifications.KBS 5.1.12 ---- as per directions of engineer in-charge of work.

35.8236

-

139169.31

... More
KSRB 5.2-3 : Providing and constructing granite / trap / basalt size stone masonry in foundation with cement mortar 1:6, stone hammerd dressed in courses not less than 20 cms high, bond stones at two m. apart in each course including cost of materials, labour, curing complete as per specifications. KBS 5.1.13 ---- as per directions of engineer in-charge of work.

45.6647

-

234578.19

... More
KSRB 4.2.2 : Providing and laying in position reinforced cement concrete of Design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregtes @ 0.460 cum, with super plasticisers @ 3 liters confirming to is 9103-1999 reafirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in foundation for footings, pedastals, retaining walls, return walls, walls (any thickness) including attached pilasters, columnspillars, posts, struts, buttresses, bed blocks, anchor blocks & plinths etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 ---- as per directions of engineer in-charge of work.

16.1463

-

97709.98

... More
KSRB 4-6.4 : Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for vertical surface such as walls at any thickness, including attached pilasters, buttresses, plinth cills and string courses cost of all materials, labour complete as per specifications. Specification No. KBS 4.6.2 ---- as per directions of engineer in-charge of work.

140.591

-

53202.45

... More
KSRB 4-1.7 : Providing and laying in position plain cement concrete of mix 1:3:6 with OPC cement @ 220kgs, with 20mm and down size graded granite metal coarse aggregates @0.84cum and fine aggregtes @ 0.56cum, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, plinth and cills, ncluding cost of all materials, labour, HOM of machinery, curing complete as per specifications. Specification No. KBS 4.1, 4.2 ---- as per directions of engineer in-charge of work.

2.9937

-

17177.19

... More
KSRB 4-1.7 : Providing and laying in position plain cement concrete of mix 1:3:6 with OPC cement @ 220kgs, with 20mm and down size graded granite metal coarse aggregates @0.84cum and fine aggregtes @ 0.56cum, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, plinth and cills, ncluding cost of all materials, labour, HOM of machinery, curing complete as per specifications. Specification No. KBS 4.1, 4.2 ---- as per directions of engineer in-charge of work.

1.6908

-

9990.35

... More
KSRB 2.3 : Filling available excavated earth ( excluding rock ) in sides of foundations upto plinth in layers not exceeding 20 cms. in depth, compacting each deposited layer by ramming after watering with lead upto 50 m. and lift upto 1.5 m. including cost of all labour complete as per specifications. specification. No. KBS 2.9 ---- as per directions of engineer in-charge of work.

87.717

-

18688.98

... More
KSRB 2.5 : Earthwork excavation in all soil deposits and filling sides of foundation upto plinth in layers not exceeding 20cms. in depth, compacting each deposited layer by ramming after watering with all lead and lift including cost of all labour complete as per specifications. specification. No. KBS 2.9.9 / 2.9.10.1 / 2.1.1 ---- as per directions of engineer in-charge of work.

224.7108

-

95991.96

... More
KSRB 6-1.3 : Providing and constructing burnt brick masonry for basement and superstructure with approved quality of non-modular bricks of standard size of class designation 3.5Newton per sqmm with cement mortar1:6 including cost of materials, labour charges, scaffolding, curing complete as per specifications. Specification No. KBS 6.2 ---- as per directions of engineer in-charge of work.

69.5532

-

444201.51

... More
KSRB 6-1.3 : Providing and constructing burnt brick masonry for basement and superstructure with approved quality of non-modular bricks of standard size of class designation 3.5Newton per sqmm with cement mortar1:6 including cost of materials, labour charges, scaffolding, curing complete as per specifications. Specification No. KBS 6.2 ---- as per directions of engineer in-charge of work.

47.3134

-

306560.55

... More
KSRB 6-7.3 : Construction of partition wall 11.2 cms thick with non-modular ground moulded burnt bricks of class designation 3.5 Newton per sqmm with cement mortar 1:4 including cost of materials, labour charges, scaffolding, curing complete as per specifications. Specification No. KBS 6.2 ---- as per directions of engineer in-charge of work.

73.9586

-

61854.54

... More
KSRB 6-7.3 : Construction of partition wall 11.2 cms thick with non-modular ground moulded burnt bricks of class designation 3.5 Newton per sqmm with cement mortar 1:4 including cost of materials, labour charges, scaffolding, curing complete as per specifications. Specification No. KBS 6.2 ---- as per directions of engineer in-charge of work.

35.9993

-

30496.81

... More
KSRB 4.2.8: Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in ground floor level for roof slabs, staircase, lintles, and beams retaining walls, return walls, walls (any thickness) including attached plasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 ---- as per directions of engineer in-charge of work.

6.5813

-

41452.45

... More
KSRB 4.2.8: Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in ground floor level for roof slabs, staircase, lintles, and beams retaining walls, return walls, walls (any thickness) including attached plasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 ---- as per directions of engineer in-charge of work.

3.0163

-

19190.06

... More
KSRB 4.2.8: Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in ground floor level for roof slabs, staircase, lintles, and beams retaining walls, return walls, walls (any thickness) including attached plasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 ---- as per directions of engineer in-charge of work.

13.431

-

84595.42

... More
KSRB 4.2.8: Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in ground floor level for roof slabs, staircase, lintles, and beams retaining walls, return walls, walls (any thickness) including attached plasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 ---- as per directions of engineer in-charge of work.

5.0854

-

32353.93

... More
KSRB 4.2.8: Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in ground floor level for roof slabs, staircase, lintles, and beams retaining walls, return walls, walls (any thickness) including attached plasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 ---- as per directions of engineer in-charge of work.

2.6176

-

16487.01

... More
KSRB 4-6.7 :Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for sides and soffits of beams, beam haunchings, cantilever girders, bressumers and lintels not exceeding 1m in depth including cost of all materials, labour complete as per specifications. Specification No. KBS 4.6.2 ---- as per directions of engineer in-charge of work.

71.2501

-

22053.33

... More
KSRB 4-6.7 :Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for sides and soffits of beams, beam haunchings, cantilever girders, bressumers and lintels not exceeding 1m in depth including cost of all materials, labour complete as per specifications. Specification No. KBS 4.6.2 ---- as per directions of engineer in-charge of work.

33.4161

-

10342.95

... More
KSRB 4-6.7 :Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for sides and soffits of beams, beam haunchings, cantilever girders, bressumers and lintels not exceeding 1m in depth including cost of all materials, labour complete as per specifications. Specification No. KBS 4.6.2 ---- as per directions of engineer in-charge of work.

116.796

-

36150.7

... More
KSRB 4-6.7 :Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for sides and soffits of beams, beam haunchings, cantilever girders, bressumers and lintels not exceeding 1m in depth including cost of all materials, labour complete as per specifications. Specification No. KBS 4.6.2 ---- as per directions of engineer in-charge of work.

44.22

-

13686.97

... More
KSRB 4-6.11 :Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for Stairs (excluding landing) except spiral staircase including cost of all materials, labour complete as per specificaiton. Specification No. KBS 4.6.2 ---- as per directions of engineer in-charge of work.

15.072

-

8004.14

... More
KSRB 4.2.10 : Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 24kgs, with 12mm and down size graded granite metal coarse aggregates @0.05175cum and fine aggregtes @ 0.0345cum, with superplastisiser @0.225lts, machine mixed, well compacted for plain chajja of 7.5 cms. average thickness, upto ground floor level, including cost of all materials, labour, HOM of machinery, finishing, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 ---- as per directions of engineer in-charge of work.

15.45

-

7271.39

... More
KSRB 4.2.10 : Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 24kgs, with 12mm and down size graded granite metal coarse aggregates @0.05175cum and fine aggregtes @ 0.0345cum, with superplastisiser @0.225lts, machine mixed, well compacted for plain chajja of 7.5 cms. average thickness, upto ground floor level, including cost of all materials, labour, HOM of machinery, finishing, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 ---- as per directions of engineer in-charge of work.

8.1

-

3949.88

... More
KSRB 4-6.10 :Providing and removing centering, shuttering, strutting, propping etc., for chajjas, corbels etc., including edges including cost of all materials, labour complete as per specifications. Specification No. KBS 4.6.2 ---- as per directions of engineer in-charge of work.

15.45

-

5240.64

... More
KSRB 4-6.10 :Providing and removing centering, shuttering, strutting, propping etc., for chajjas, corbels etc., including edges including cost of all materials, labour complete as per specifications. Specification No. KBS 4.6.2 ---- as per directions of engineer in-charge of work.

8.1

-

2747.52

... More
KSRB 4-2.12 : Extra for providing throating or drip moulding to R.C.C. chajja with plastering ( labour charges only ) as per specifications. Specification No. KBS ---- as per directions of engineer in-charge of work.

42.55

-

1488.4

... More
KSRB 4-2.12 : Extra for providing throating or drip moulding to R.C.C. chajja with plastering ( labour charges only ) as per specifications. Specification No. KBS ---- as per directions of engineer in-charge of work.

23.1

-

808.04

... More
KSRB 4.2.8: Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in ground floor level for roof slabs, staircase, lintles, and beams retaining walls, return walls, walls (any thickness) including attached plasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 ---- as per directions of engineer in-charge of work.

43.8968

-

276484.87

... More
KSRB 4.2.8: Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in ground floor level for roof slabs, staircase, lintles, and beams retaining walls, return walls, walls (any thickness) including attached plasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 ---- as per directions of engineer in-charge of work.

16.0818

-

102314.34

... More
KSRB 4-6.1 : Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for foundations, footings, bases of columns for mass concrete including cost of all materials, labour complete as per specificaitons. Specification No. KBS 4.6.2 ---- as per directions of engineer in-charge of work.

310.6697

-

83974.02

... More
KSRB 4-6.1 : Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for foundations, footings, bases of columns for mass concrete including cost of all materials, labour complete as per specificaitons. Specification No. KBS 4.6.2 ---- as per directions of engineer in-charge of work.

129.8016

-

35085.37

... More
KSRB 4-1.5 : Providing and laying in position plain cement concrete of mix M20 with OPC cement @ 300kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregtes @ 0.43cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, plinth and cills, including cost of all materials, labour, HOM of machinery, curing complete as per specifications. Specification No. KBS 4.1, 4.2 ---- as per directions of engineer in-charge of work.

12.9254

-

73656.17

... More
KSRB 4-4.2 : Extra for use of water proofing compound in Cement concrete of mix 1:1.5:3,at one kg of compound per bag of cement. Specification No. KBS ---- as per directions of engineer in-charge of work.

12.9254

-

2123.64

... More
KSRB 4-1.5 : Providing and laying in position plain cement concrete of mix M20 with OPC cement @ 300kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregtes @ 0.43cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, plinth and cills, including cost of all materials, labour, HOM of machinery, curing complete as per specifications. Specification No. KBS 4.1, 4.2 ---- as per directions of engineer in-charge of work.

6.9687

-

41106.2

... More
KSRB 4-4.2 : Extra for use of water proofing compound in Cement concrete of mix 1:1.5:3,at one kg of compound per bag of cement. Specification No. KBS ---- as per directions of engineer in-charge of work.

6.9687

-

1144.96

... More
For roof slab & terraces Providing & applying water proofing to roof slab, terraces, landscape area, podium etc., using modified polyurethane cures (conforming to ASTM C836-84) to give a tough elastomeric waterproof membrane on the surface. The surface shall be cleaned free from dust and other particle before usage. standards & methodology : This compound has a medium viscosity grade with 620% of elongation and shall be done either by roller application/brush application/ spray. This will be applied for a thickness of 1.3mm first layer 0.5mm & 2nd layer 0.8mm. After applying the 2nd layer sand sprinkle shall be done to provide mechanical key. ---- as per directions of engineer in-charge of work.

253.5015

-

188098.11

... More
For roof slab & terraces Providing & applying water proofing to roof slab, terraces, landscape area, podium etc., using modified polyurethane cures (conforming to ASTM C836-84) to give a tough elastomeric waterproof membrane on the surface. The surface shall be cleaned free from dust and other particle before usage. standards & methodology : This compound has a medium viscosity grade with 620% of elongation and shall be done either by roller application/brush application/ spray. This will be applied for a thickness of 1.3mm first layer 0.5mm & 2nd layer 0.8mm. After applying the 2nd layer sand sprinkle shall be done to provide mechanical key. ---- as per directions of engineer in-charge of work.

158.2136

-

117394.49

... More
Providing and casting reinforced cement concrete racks with design mix M20, granite or trap jelly 12mm and down size 5 cms thick and below with reinforcements of 6mm dia MS bars at 15 cms. Centre to centre for main reinforcement and at 30cms centre to centre for distribution including supports wherever necessary with burnt brick in CM 1:4 including centring, form work, curing etc., complete (inclusive of cost of steel and fabrication charges). ---- as per directions of engineer in-charge of work.

7.404

-

7746.21

... More
Providing and casting reinforced cement concrete racks with design mix M20, granite or trap jelly 12mm and down size 5 cms thick and below with reinforcements of 6mm dia MS bars at 15 cms. Centre to centre for main reinforcement and at 30cms centre to centre for distribution including supports wherever necessary with burnt brick in CM 1:4 including centring, form work, curing etc., complete (inclusive of cost of steel and fabrication charges). ---- as per directions of engineer in-charge of work.

1.842

-

1927.14

... More
Providing and fixing RCC slabs 5 cms thick for wall shelves with 12mm and down size jelly cement concrete design mix M20 including CM 1:3 plaster finishing, curing etc., complete (excluding the cost of steel and fabrication charges ---- as per directions of engineer in-charge of work.

17.019

-

11184.89

... More
Providing and fixing RCC slabs 5 cms thick for wall shelves with 12mm and down size jelly cement concrete design mix M20 including CM 1:3 plaster finishing, curing etc., complete (excluding the cost of steel and fabrication charges ---- as per directions of engineer in-charge of work.

22.59

-

15142.08

... More
KSRB15-3.14 : Providing 12mm thick cement plaster in single coat with cement mortar 1:4, to ceiling including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. ---- as per directions of engineer in-charge of work.

274.6932

-

65223.15

... More
KSRB15-3.14 : Providing 12mm thick cement plaster in single coat with cement mortar 1:4, to ceiling including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. ---- as per directions of engineer in-charge of work.

86.1358

-

21205.77

... More
KSRB15-3.3 : Providing 12mm thick cement plaster in single coat with cement mortar 1:6, to brick masonry including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. ---- as per directions of engineer in-charge of work.

734.8777

-

150341.28

... More
KSRB15-3.3 : Providing 12mm thick cement plaster in single coat with cement mortar 1:6, to brick masonry including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. ---- as per directions of engineer in-charge of work.

330.7695

-

70255.44

... More
Providing applying two coats of wall putty to inside plastered walls and ceiling using white cement putty. Scrapping and levelling the surface using steel blade and preparing the surface even and smooth by using different grade sand papers, including cost of all materials, cost of labour and scaffolding etc., complete as per the specification. Area to be considered - (a) 100% for fresh surface (b) Upto 10% for repainting ---- as per directions of engineer in-charge of work.

1017.88

-

84158.32

... More
Providing applying two coats of wall putty to inside plastered walls and ceiling using white cement putty. Scrapping and levelling the surface using steel blade and preparing the surface even and smooth by using different grade sand papers, including cost of all materials, cost of labour and scaffolding etc., complete as per the specification. Area to be considered - (a) 100% for fresh surface (b) Upto 10% for repainting ---- as per directions of engineer in-charge of work.

443.77

-

36690.9

... More
KSRB15-3.8 : Providing 18mm thick cement plaster in single coat with cement mortar 1:4, to brick masonry including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. ---- as per directions of engineer in-charge of work.

328.1663

-

90442.63

... More
KSRB15-4.4 Extra for providing and mixing waterproofing compound in cement plaster work at one kg per bag or in the proportion recommended by the manufacturers, forcement mortar 1:4, 18mm thick cost of materials complete as per specifications. ---- as per directions of engineer in-charge of work.

328.1663

-

2782.85

... More
KSRB15-3.8 : Providing 18mm thick cement plaster in single coat with cement mortar 1:4, to brick masonry including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. ---- as per directions of engineer in-charge of work.

338.8076

-

98925.04

... More
KSRB15-4.4 Extra for providing and mixing waterproofing compound in cement plaster work at one kg per bag or in the proportion recommended by the manufacturers, forcement mortar 1:4, 18mm thick cost of materials complete as per specifications. ---- as per directions of engineer in-charge of work.

338.8076

-

2873.09

... More
KSRB 9.4-2 : Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves ( excluding cost of cement concrete and side clamps ), but including cost of materials, labour, HOM of machineries complete as per specifications. Specification No. KBS 9.33 ---- as per directions of engineer in-charge of work.

0.47

-

42232.91

... More
KSRB 9.4-2 : Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves ( excluding cost of cement concrete and side clamps ), but including cost of materials, labour, HOM of machineries complete as per specifications. Specification No. KBS 9.33 ---- as per directions of engineer in-charge of work.

0.258

-

23183.17

... More
KSRB 9-27.1 : Fixing of door frame in an existing opening including embeeding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debries with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- as per directions of engineer in-charge of work.

9

-

13060.26

... More
KSRB 9-27.1 : Fixing of door frame in an existing opening including embeeding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debries with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- as per directions of engineer in-charge of work.

5

-

7255.7

... More
KSRB 9.5-2 : Providing and fixing in position fully panelled Honne wood shutters for doors, styles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and styles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, HOM of machineries complete as per specifications. ( excluding cost of fixtures) Specification No. KBS 9.34 ---- as per directions of engineer in-charge of work.

1.64

-

8022.72

... More
KSRB 9.5-2 : Providing and fixing in position fully panelled Honne wood shutters for doors, styles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and styles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, HOM of machineries complete as per specifications. ( excluding cost of fixtures) Specification No. KBS 9.34 ---- as per directions of engineer in-charge of work.

6.56

-

32118.68

... More
Providing and fixing factory made splendoor of solid core single leaf rigid composite polymer laminated sal wood, door shutter of required thickness, manufactured out of solid core door conforming to IS 2202 (Part-1) 1991, laminated with 0.8 mm thick polymer, termite, water resistant and fire retardant with superior gluing based on vacuum lamination technology and with various pre moulded design on both faces conforming to IS 6307-1985, using adhesive conforming to IS 4835-1979 and door shuters tested in conformation to IS 4020-1994. The finish of shutters will be TEADK/OAK/CEDAR/ROSE WOOD/ WALNUT, plain colurs WHITE/IVORY/BEIGE/LIGHT GREY. Excluding cost of fixtures and inclusive of supply of shutters to respective work spot. with door shutter 30mm thick ---- as per directions of engineer in-charge of work.

14.35

-

49435.75

... More
Providing and fixing factory made splendoor of solid core single leaf rigid composite polymer laminated sal wood, door shutter of required thickness, manufactured out of solid core door conforming to IS 2202 (Part-1) 1991, laminated with 0.8 mm thick polymer, termite, water resistant and fire retardant with superior gluing based on vacuum lamination technology and with various pre moulded design on both faces conforming to IS 6307-1985, using adhesive conforming to IS 4835-1979 and door shuters tested in conformation to IS 4020-1994. The finish of shutters will be TEADK/OAK/CEDAR/ROSE WOOD/ WALNUT, plain colurs WHITE/IVORY/BEIGE/LIGHT GREY. Excluding cost of fixtures and inclusive of supply of shutters to respective work spot. with door shutter 30mm thick ---- as per directions of engineer in-charge of work.

1.64

-

5656.75

... More
KSRB 15.1.1 Providing flush pointing to square rubble, course or uncoursed stone masonry with cement mortar 1:3, 20mm deep, after raking joints to depth of 20mm nicely lining, including cost of materials, labour, curing complete as per specifications. ---- as per directions of engineer in-charge of work.

79.044

-

11813.92

... More
KSRB15-3.11 : Providing 20mm thick cement plaster in single coat with cement mortar 1:4, to stone masonry & concrete surface including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. ---- as per directions of engineer in-charge of work.

127.655

-

36534.86

... More
KSRB 14.10-1: Flooring with 25mm to 40mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. Specification No. KBS ---- as per directions of engineer in-charge of work.

60.7258

-

80590.42

... More
Providing and fixing Vitrified glazed tiles of approved make, quality & colour of size 900 x 900 x 12mm thick fixed on bed of 12mm thick cement mortar for flooring, skirting and JOinted with neat cement slurry mixed with pigment to mach shade of tiles, including providing spacers at required interval and removing stains, including cost of all mateirals, mortar, labour, etc., Complete as per specification. ---- as per directions of engineer in-charge of work.

158.2332

-

190538.09

... More
Providing and fixing Vitrified glazed tiles of approved make, quality & colour of size 900 x 900 x 12mm thick fixed on bed of 12mm thick cement mortar for flooring, skirting and JOinted with neat cement slurry mixed with pigment to mach shade of tiles, including providing spacers at required interval and removing stains, including cost of all mateirals, mortar, labour, etc., Complete as per specification. ---- as per directions of engineer in-charge of work.

70.2961

-

84647.75

... More
KSRB 14.14-5: Providing Ceramic tiles of approved make,shade and size for flooring, treads of steps and landings laid on a bed of 12mm thick, cement mortar 1:3 mix, flush pointing with white cement using colour pigment , including cost of materials, labour, curing, complete as per specifications. - for Ceramic Tiles of size 30x30cms 6mm thick ---- as per directions of engineer in-charge of work.

17.8835

-

22899.46

... More
KSRB 14.14-5: Providing Ceramic tiles of approved make,shade and size for flooring, treads of steps and landings laid on a bed of 12mm thick, cement mortar 1:3 mix, flush pointing with white cement using colour pigment , including cost of materials, labour, curing, complete as per specifications. - for Ceramic Tiles of size 30x30cms 6mm thick ---- as per directions of engineer in-charge of work.

11.0031

-

14163.52

... More
KSRB 14-17.2 : Providing skirting, dado, rises of steps with colour glazed tiles on 10mm thick cement plaster 1:3 and jointed with white cement slurry over rough plaster surface ( excluding cost of rough plastered surface which should be measured and paid separately) using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. Specification No.KBS 14.16, 14.17 - Colour glazed tiles 30x60 cms 6mm thick with border of size 30 x 10 cms ---- as per directions of engineer in-charge of work.

77.889

-

134576.61

... More
KSRB 14-17.2 : Providing skirting, dado, rises of steps with colour glazed tiles on 10mm thick cement plaster 1:3 and jointed with white cement slurry over rough plaster surface ( excluding cost of rough plastered surface which should be measured and paid separately) using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. Specification No.KBS 14.16, 14.17 - Colour glazed tiles 30x60 cms 6mm thick with border of size 30 x 10 cms ---- as per directions of engineer in-charge of work.

42.99

-

74557.99

... More
KSRB 4-5 : Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixing chicken mesh for drop chajja, facia, backing to cup boards including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specifications. Specification No. KBS ---- as per directions of engineer in-charge of work.

59.058

-

66733.18

... More
uPvC Windows and Doors - Providing & fixing of glazed 3 Track - 2 Panel Sliding Door With Mesh … made out of multi chambered uPVC sections with TPV gaskets having isolated drainage and reinforced with Galvanized Iron profiles through out the window. The sliding outer frame having a overall size of 108x45 mm with reinforcement of 1 mm thickness, super sash with overall size of 39x75 mm with reinforcement of 1.5 mm thickness, mesh sash of overall size 30x48.5 mm reinforced with 1.5 mm of GI.Glazing bead for fixing of glas shall be of size 20x18mm and coextruded with gasket. Fiber Glass mesh shall be provided in mesh shutter. Window/Door shall be provided with 6 mm plain float glass, standard hardware & multi point locking system of Patio espagnolette. Wall thickness of frame, mullion & sash shall be 2-2.2 mm. ---- as per directions of engineer in-charge of work.

35.0325

-

210738

... More
uPvC Windows and Doors - Providing & fixing of glazed 3 Track - 2 Panel Sliding Door With Mesh … made out of multi chambered uPVC sections with TPV gaskets having isolated drainage and reinforced with Galvanized Iron profiles through out the window. The sliding outer frame having a overall size of 108x45 mm with reinforcement of 1 mm thickness, super sash with overall size of 39x75 mm with reinforcement of 1.5 mm thickness, mesh sash of overall size 30x48.5 mm reinforced with 1.5 mm of GI.Glazing bead for fixing of glas shall be of size 20x18mm and coextruded with gasket. Fiber Glass mesh shall be provided in mesh shutter. Window/Door shall be provided with 6 mm plain float glass, standard hardware & multi point locking system of Patio espagnolette. Wall thickness of frame, mullion & sash shall be 2-2.2 mm. ---- as per directions of engineer in-charge of work.

21.195

-

127498.52

... More
Providing and fixing PVC Hollow Door Frame of the size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet, mitre cut at two corners and joined with 2 Nos. of 15Dmm long brackets of 15x15mm M.S. Square tube. The two vertical door profiles are to be reinforced with 19x19 mm M.S. Square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door screws through the frame by using PVC fasteners. A minimum of 4 Nos of screws to be provided for each vertical member & minimum 2 Nos. for horizontal member ---- as per directions of engineer in-charge of work.

24.8

-

9463.68

... More
Providing and fixing PVC Hollow Door Frame of the size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet, mitre cut at two corners and joined with 2 Nos. of 15Dmm long brackets of 15x15mm M.S. Square tube. The two vertical door profiles are to be reinforced with 19x19 mm M.S. Square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door screws through the frame by using PVC fasteners. A minimum of 4 Nos of screws to be provided for each vertical member & minimum 2 Nos. for horizontal member ---- as per directions of engineer in-charge of work.

15

-

5724

... More
Providing and fixind of factory made 30mm P.V.C rigid foam PANEL DOORS made from MS tube of 19 guage, size of 19mm x 19mm and covered with heat moulded PVC C Channel of 5 mm thick and width of 50mm to form styles and rails. The inner panel should be inserted in between the frame with 5mm thick PVC rigid foam sheet, welded/sealed to the styles and rails along with 5mm PVC, beeding on all and either sides. The vertical tubes may be filled with suitable wood material to further enhance the screw holding capacity ---- as per directions of engineer in-charge of work.

7.42

-

18876.48

... More
Providing and fixind of factory made 30mm P.V.C rigid foam PANEL DOORS made from MS tube of 19 guage, size of 19mm x 19mm and covered with heat moulded PVC C Channel of 5 mm thick and width of 50mm to form styles and rails. The inner panel should be inserted in between the frame with 5mm thick PVC rigid foam sheet, welded/sealed to the styles and rails along with 5mm PVC, beeding on all and either sides. The vertical tubes may be filled with suitable wood material to further enhance the screw holding capacity ---- as per directions of engineer in-charge of work.

4.305

-

10970.17

... More
KSRB 7.9 : Providing and fixing M.S.grill work for windows and ventilators weighing 21kg/sqm using M.S. flats, or M.S. square rods, or combination of M.S. flats and square rods as per approved design, drawing including cutting steel sections and welding the same to required pattern with a coat of red lead primer, cost of materials, fixtures, labour and HOM of machinery complete as per specifications. Specification No. KBS 7.12 ---- as per directions of engineer in-charge of work.

2898.63

-

291892.04

... More
KSRB 7.9 : Providing and fixing M.S.grill work for windows and ventilators weighing 21kg/sqm using M.S. flats, or M.S. square rods, or combination of M.S. flats and square rods as per approved design, drawing including cutting steel sections and welding the same to required pattern with a coat of red lead primer, cost of materials, fixtures, labour and HOM of machinery complete as per specifications. Specification No. KBS 7.12 ---- as per directions of engineer in-charge of work.

445.2

-

44831.64

... More
KSRB 15-15.1 : Providing and applying painting in two coats with plastic emulsion paint of approved brand on wall surface to give an even approved shade after thoroughly brushing the surface, free from mortar drops and other foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour, complete as per specifications. - with primer ---- as per directions of engineer in-charge of work.

316.13

-

30158.8

... More
KSRB 15-15.2 : Extra over Item 15-15.1 for painting two coats with plastic emulsion paint of approved brand and shade on ceiling and / or sloping roof as per specifications. ---- as per directions of engineer in-charge of work.

316.13

-

1675.49

... More
KSRB 15-15.1 : Providing and applying painting in two coats with plastic emulsion paint of approved brand on wall surface to give an even approved shade after thoroughly brushing the surface, free from mortar drops and other foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour, complete as per specifications. - with primer ---- as per directions of engineer in-charge of work.

133.16

-

12703.46

... More
KSRB 15-15.2 : Extra over Item 15-15.1 for painting two coats with plastic emulsion paint of approved brand and shade on ceiling and / or sloping roof as per specifications. ---- as per directions of engineer in-charge of work.

133.16

-

705.75

... More
KSRB 15-15.1 : Providing and applying painting in two coats with plastic emulsion paint of approved brand on wall surface to give an even approved shade after thoroughly brushing the surface, free from mortar drops and other foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour, complete as per specifications. - with primer ---- as per directions of engineer in-charge of work.

734.88

-

70107.55

... More
KSRB 15-15.1 : Providing and applying painting in two coats with plastic emulsion paint of approved brand on wall surface to give an even approved shade after thoroughly brushing the surface, free from mortar drops and other foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour, complete as per specifications. - with primer ---- as per directions of engineer in-charge of work.

330.77

-

31555.46

... More
Providing and finishing external walls in two coats over one coat of primer with antifungal paint of approved brand and shade to give an even shade after thoroughly brooming the surface to remove all dirt and loose powdered material, free from mortar drops and other foreign matter cost of materials, labour, complete as per specifications. ---- as per directions of engineer in-charge of work.

525.33

-

100232.96

... More
Providing and finishing external walls in two coats over one coat of primer with antifungal paint of approved brand and shade to give an even shade after thoroughly brooming the surface to remove all dirt and loose powdered material, free from mortar drops and other foreign matter cost of materials, labour, complete as per specifications. ---- as per directions of engineer in-charge of work.

338.81

-

67518.06

... More
KSRB 15-17.6 : Providing and applying painting two coats ( excluding priming coat ) on new wood surface and / or wood based surface with enamel paint to give an even shade, cleaning the surface of all dirt, dust and foreign matter, sand papering including cost of materials, labour, complete as per specifications. ---- as per directions of engineer in-charge of work.

80.3972

-

8266.44

... More
KSRB 15-17.2 : Applying priming coat over new wood surface and / or wood based surface after brushing with wood primer pink paint including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, sand papering and knotting ready mix paint including cost of materials, labour, complete as per specifications. ---- as per directions of engineer in-charge of work.

80.3972

-

3920.17

... More
KSRB 15-17.6 : Providing and applying painting two coats ( excluding priming coat ) on new wood surface and / or wood based surface with enamel paint to give an even shade, cleaning the surface of all dirt, dust and foreign matter, sand papering including cost of materials, labour, complete as per specifications. ---- as per directions of engineer in-charge of work.

41.709

-

4288.52

... More
KSRB 15-17.2 : Applying priming coat over new wood surface and / or wood based surface after brushing with wood primer pink paint including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, sand papering and knotting ready mix paint including cost of materials, labour, complete as per specifications. ---- as per directions of engineer in-charge of work.

41.709

-

2033.73

... More
KSRB15-5.2 : Providing rough cement plastering 15mm thick in single coat with cement mortar 1:6, to brick masonry for base of dadooing works with sand of approved quality, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. ---- as per directions of engineer in-charge of work.

77.889

-

15851.97

... More
KSRB15-5.2 : Providing rough cement plastering 15mm thick in single coat with cement mortar 1:6, to brick masonry for base of dadooing works with sand of approved quality, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. ---- as per directions of engineer in-charge of work.

42.99

-

9106.57

... More
Providing wall black boards in CM 1:3 with two coats of black paint including finishing etc., including cost of materials, labour, HOM complete as per specifications. ---- as per directions of engineer in-charge of work.

21.6

-

17675.71

... More
KSRRB M800- Painting Letters KSRRB M800-6. Painting two coats on New Concrete Surface : Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces complete as per specifications. MORTH Specification No. 803 ---- as per directions of engineer in-charge of work.

9

-

782.28

... More
KSRRBM800-9. Painting New Letter and Figures of any Shade with synthetic enamel paint black or any other approved colour to give an even shade complete as per specifications. (“i) Hindi ( Matras commas and the like not to be measured and paid for half letter shall be counted as half) “ MORTH Specification No. 803 ---- as per directions of engineer in-charge of work.

4000

-

4240

... More
KSRB 7.14 : Providing, fabricating, assembling and fixing in position aluminium partitions using sections in combination of plain, single grove and double grove as per requirements for the frames of overall size 101.6mm x 44.45mm, 3.18mm.thick having section weight, plain sections 2.40kg/m single grove section 2.541kg/m. and double grovesection 2.683 kg/m and bottom 46 kg/m; aluminium louvres of size 77.6mmx27.6mm 1.7mm. thick section weight 0.483kg/m; bottom portions provided with 12mm. thick prelaminated sheet both side of approved colour lamination exterior grade; aluminium sections of mat finish or glossy finish using section, spacing of vertical member shall not exceed 0.6 m. c to c; sections are cut to the required lengths, joints mitered and corners grinded subdividing frames tennoned and rivetted to the frames, the assembled frame should be stiffened with corner angles stripped and fixed with screws, rawl plugs and teak wood gutties to R.C.C.columns or masonry on sides, R.C.C. lintels or beams at top and floor at bottom, including cutting chistling and making good with cement mortar to match the surface, providing and fixing bottom panel filled with the materials to a height of 0.9m. from floor level; and 5.5mm. thick plain glass for middle portion viz., 0.9m. to 2.13 m. and top panel with lower sections, the glass and panels fitted with glazing clips of 19mmx17.3mm. with thickness of 0.9mm. weight 0.124kg/m; aluminium sections pre-treated for removal of any rust and prevention of further rust formation, and coated with greasy materials for non-adherence of mortars or any other sticky materials; vertical members embedded in the flooring by making suitable size holes and fixing with cement mortar, with necessary opening for fixing of doors of standard size (excluding cost of door opening) All the frame should be throughly cleaned free from rust, scale or dirt including cost of materials, fixtures, labour and HOM of machinery complete as per specifications. using aluminium section powdered coated to a minimum of 60-70 microns with exterior durable pure polyester grade powder of approved quality. ---- as per directions of engineer in-charge of work.

7.215

-

36671.68

... More
KSRB 14.10-3: Providing flooring with 25mm to 40mm thick polished Cadapa slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, including cost of materials, labour, curing, polishing complete as per specifications. Specification No. KBS ---- as per directions of engineer in-charge of work.

6.084

-

8293.47

... More
KSRB 14.10-3: Providing flooring with 25mm to 40mm thick polished Cadapa slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, including cost of materials, labour, curing, polishing complete as per specifications. Specification No. KBS ---- as per directions of engineer in-charge of work.

24.264

-

33280.99

... More
KSRB 7.17 : Providing, fabricating, assembling and fixing in position aluminium doors using following aluminium mat finish or glossy finish, outer frame plain section 101.6x44.45mm thickness 3.18mm, section weight 2.404 kg/m, door shutters vertical section 44.62x44.45mm thickness 3.18mm, section weight 1.505kg/m, top section 47.62x44.45mm thickness 3.00mm, section weight 1.426kg/m bottom section 114.3x44.45 thickness 3.18mm, section weight 2.646kg/m, door central section 49.91x44.45mm thickness 3.00mm, section weight 1.495 kg/m glazing clips 19x17.3x11mm thickness 0.9mm section weight 0.124kg/m; aluminium sections cut to length joint metred cornersgrinded, the shutters pivoted opening arrangement with heavy duty aluminium alloy automatic door closures floor mounted, providing and fixing standard approved accessories, such as aluminium handle for full width or length, tower bolts, lock, pivots: P.V.C. or rubber gasket with 5.5m. thick plain glass for top and bottom panel; aluminium sections treated for removal of any rust and prevention of further rust formation, and coated with greasy materials for non-adherance of mortars or any other sticky materials; the assembled frame fitted with the corner angles, strips and fitted with screws, rawl plugs or teakwood gutties to R.C.C. columns or masonry on sides. beams and flooring in bottom. including cutting, chistling and making good with cement mortar to match the surface; all the frames throughly cleaned free from rust, scale, or dirt including cost of materials, fixtures, labour and HOM of machinery complete as per specifications. using aluminium section powdered coated to a minimum of 60-70 microns with exterior durable pure polyester grade powder of approved quality. ---- as per directions of engineer in-charge of work.

2.205

-

14538.01

... More
Providing and laying flooring using prepolished, water cut/gang saw 19mm thick granite laid over bed of 20mm thick 1:4 cm & jointed with neat cement slurry mixed with pigment to mach shade of granite slabs including laying POP on finished surface and cleaning the surface, including the cost of all materials and labours etc., complete as per specifications. - using silver grey granite / Multy Red / Ruby Red / Black / HassanGreen Granite of width not less than 1200mm ---- as per directions of engineer in-charge of work.

41.5763

-

120621.99

... More
KSRB 2-2.1 : Earthwork excavation by manual means for foundation of buildings, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in ordinary soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. after breaking of clods complete as per specifications. specification. No. KBS 2.1(a) / 2.3.5 ---- as per directions of engineer in-charge of work.

64.095

-

20314.27

... More
KSRB 2-4 : Refilling available earth around pipe lines, cables in layers not exceeding 20cms in depth, compacting each deposited layer by ramming after watering with lead upto 50m. and lift upto 1.5 m. including cost of all labour complete as per specifications. ---- as per directions of engineer in-charge of work.

64.095

-

8220.82

... More
Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete. (Concealed work including cutting chases and good the walls etc.) - 25mm nominal OD pipes ---- as per directions of engineer in-charge of work.

53

-

16460.74

... More
Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete. (Concealed work including cutting chases and good the walls etc.) - 32mm nominal OD pipes ---- as per directions of engineer in-charge of work.

175

-

69377

... More
KSRB13-8.7 : Providing and fixing to wall, ceiling and floor, low density polyethylene pipes 6.00 kgf/sq.cm working pressure 75mm outside diameter with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. Specification No.KBS 13.2.15.1 / 13.9 ---- as per directions of engineer in-charge of work.

107

-

36974.92

... More
KSRB13-8.8 : Providing and fixing to wall, ceiling and floor, low density polyethylene pipes 6.00 kgf/sq.cm working pressure 90mm outside diameter with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. Specification No.KBS 13.2.15.1 / 13.9 ---- as per directions of engineer in-charge of work.

217

-

87407.6

... More
Providing and fixing CI Nahani trap of approved make conforming to ISI specifications and construction of Cistern in M-15 as per directions (Rate is inclusive of cost of materials and fixtures and conveyance of materials to work spot). - 12.5cms x 7.5cms ---- as per directions of engineer in-charge of work.

8

-

2416.8

... More
KSRB 13-11.1 : Providing and placing on terrace, polyethylene water storage tanks with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials, labour, transport charges, HOM of equipments and testing complete as per specifications.(For 1000 litre capacity) Specification No.KBS 13.22 ---- as per directions of engineer in-charge of work.

1

-

7237.68

... More
KSRB 12-8.1 : Constructing brick masonry inspection chamber 455x610mm, and 450mm depth, ( clear inside dimension ) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover withframe (light duty) 455x610mm internal dimensions, total weight of cover with frame to be not less than 38 kg ( weight of cover 23kg and weight of frame 15 kg) R.C.C. top slab with cement concrete M 15 with 20mm and downsize granite metal, foundation concrete M 5 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS ---- as per directions of engineer in-charge of work.

6

-

44927.04

... More
Constructing brick masonry inspection chamber 600x600mm, and 450mm depth, ( clear inside dimension ) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover withframe (light duty) 455x610mm internal dimensions, total weight of cover with frame to be not less than 38 kg ( weight of cover 23kg and weight of frame 15 kg) R.C.C. top slab with cement concrete M 15 with 20mm and downsize granite metal, foundation concrete M 5 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 600x600mm and 450mm depth ( clear inside dimension ) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover withframe (light duty) 600x600mm ---- as per directions of engineer in-charge of work.

8

-

71995.2

... More
KSRB13-6.3-4 : Providing and fixing in position brass gate valve with C.I wheel of approved quality ( screwed end ) 32mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. Specification No.KBS 13.2.6 / 13.3 ---- as per directions of engineer in-charge of work.

3

-

2639.4

... More
KSRB 11-5 : Providing and fixing white vitreous china clay, water closet European type ( Pedestal type, P-trap ) with black solid plastic seat and lid, C.P brass hinges, rubber buffers. 10 litre low level, P.V.C flushing cistern ( all are approved make ) with fittings, C.I / M.S brackets, 40mm diameter flush bend with fittings and clamps, overflow arrangements with special and 25mm mosquito proof coupling of approved design, painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specifications. Specification No. KBS 11 ---- as per directions of engineer in-charge of work.

4

-

21013.44

... More
KSRB 11-2 : Providing and fixing white vitreous china clay, water closet Orissa pattern of size 580 x 440mm with integral type footrests, 100mm S or P trap, 10 litre low level, P.V.C flushing cistern ( all are approved make ) with fittings, C.I / M.S brackets, 32mm diameter flush pipe fittings and clamps, overflow arrangements with special and 25mm mosquito proof coupling of approved design, painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specifications. Specification No. KBS 11 ---- as per directions of engineer in-charge of work.

4

-

17909.76

... More
KSRB 11-11.1 : Providing and fixing white vitreous china clay, flat back wash basin size 630x450mm with a pair of 15mm C.P brass pillar taps with C.I / M.S brackets, 32 mm C.P. brass waste of standard pattern, painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specifications. Specification No. KBS 11 ---- as per directions of engineer in-charge of work.

5

-

21237.1

... More
KSRB 11-15.3 : Providing and fixing 453x357mm dia rectangular shape mirror with plastic moulded frame of approved make and shade with 6mm thick hard board backing including cost of materials, labour complete as per specifications. ---- as per directions of engineer in-charge of work.

5

-

6020.8

... More
KSRB 11-17.2 : Providing and fixing C.P. brass towel rail 600 mm length, 20mm dia with C.P brackets, fixed to wooden cleats with C.P. brass screws including cost of materials, labour complete as per specifications. ---- as per directions of engineer in-charge of work.

6

-

4286.64

... More
Providing and fixing 7.5 cms to 15.00 cms dia NP grating 100 mm dia. ---- as per directions of engineer in-charge of work.

8

-

1272

... More
KSRB13-3.6 : Providing and fixing in trenches galvanised / mild steel tubes (medium grade) 50mm dia nominal bore with all fittings ( earth work in trenches to be measured and paid for separately ) including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. Specification No.KBS 13.2.14 / 13.6 ---- as per directions of engineer in-charge of work.

7

-

2878.96

... More
Wall bores in Brick masonry upto 45 em thick. including cost of materials, labour, HOM complete as per specifications. ---- as per directions of engineer in-charge of work.

45

-

6010.2

... More
Wall bores in size stone masonry. including cost of materials, labour, HOM complete as per specifications.- - upto 45 cm thick. ---- as per directions of engineer in-charge of work.

15

-

4817.7

... More
Providing and fixing white vitreous china clay urinals with flat back of approved make fixed to wooden plugs including bends, painting white to exposed pipes etc., complete as per directions.(rate includes cost of all materials and lead).A grade. ---- as per directions of engineer in-charge of work.

1

-

901

... More
KSRB 2-2.1 : Earthwork excavation by manual means for foundation of buildings, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in ordinary soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. after breaking of clods complete as per specifications. specification. No. KBS 2.1(a) / 2.3.5 ---- as per directions of engineer in-charge of work.

9.375

-

2971.31

... More
KSRB 2-2.2 : Earthwork excavation by manual means for foundation of buildings, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in hard soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. after breaking of clods complete as per specifications. specification. No. KBS 2.1(b) / 2.3.5 ---- as per directions of engineer in-charge of work.

1.875

-

892.39

... More
KSRB 2-2.4 : Excavation by manual means for foundation of buildings, water supply & sanitary lines and electrical conduits etc. , either in pits or in trenches 1.50m and above in width, in soft rock /ordinary rock without blasting not exceeding 1.50mtrs in depth including stacking the excavated stuff clear from edges of excavation with lead upto 50mt including cost of explosives, labour, HOM complete as per specifications. specification. No. KBS 2.1Cl2.9.412.1812.19 ---- as per directions of engineer in-charge of work.

6.5625

-

9884.83

... More
KSRB 4-1.3 : Providing and laying in position plain cement concrete of mix 1:4:8 with OPC cement @ 180kgs, with 40mm and down size graded granite metal coarse aggregates @0.85cum and fine aggregates @ 0.57cum machine mixed, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, including cost of all materials, labour, HOM of machinery, curing complete as per specifications. Specification No. KBS 4.1, 4.2 ---- as per directions of engineer in-charge of work.

0.9375

-

5248.79

... More
KSRB 6-1.3 : Providing and constructing burnt brick masonry for basement and superstructure with approved quality of non-modular bricks of standard size of class designation 3.5Newton per sqmm with cement mortar1:6 including cost of materials, labour charges, scaffolding, curing complete as per specifications. Specification No. KBS 6.2 ---- as per directions of engineer in-charge of work.

3.6928

-

23692.12

... More
KSRB 4.2.8: Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in ground floor level for roof slabs, staircase, lintles, and beams retaining walls, return walls, walls (any thickness) including attached plasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 ---- as per directions of engineer in-charge of work.

0.7399

-

4660.27

... More
KSRB 4-6.1 : Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for foundations, footings, bases of columns for mass concrete including cost of all materials, labour complete as per specificaitons. Specification No. KBS 4.6.2 ---- as per directions of engineer in-charge of work.

5.2792

-

1426.97

... More
KSRB 4-1.6 ; Providing and laying in position plain cement concrete of mix 1:2:4 with cement @ 240kgs, with 20mm and down size graded granite metal coarse aggregates @ 0.69 cum and fine aggregtes @ 0.459cum, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, plinth and cills, ncluding cost of all materials, labour, HOM of machinery, curing complete as per specifications. Specification No. KBS 4.1, 4.2 ---- as per directions of engineer in-charge of work.

0.49

-

2927.02

... More
KSRB15-3.11 : Providing 20mm thick cement plaster in single coat with cement mortar 1:4, to stone masonry & concrete surface including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. ---- as per directions of engineer in-charge of work.

14.4

-

4177.44

... More
KSRB15-4.5 Extra for providing and mixing waterproofing compound in cement plaster for stone masonry work at one kg per bag or in the proportion recommended by the manufacturers, for cement mortar 1:4, 20mm thick cost of materials complete as per specifications. ---- as per directions of engineer in-charge of work.

14.4

-

137.38

... More
KSRB15-3.14 : Providing 12mm thick cement plaster in single coat with cement mortar 1:4, to ceiling including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. ---- as per directions of engineer in-charge of work.

4

-

949.76

... More
KSRB15-3.8 : Providing 18mm thick cement plaster in single coat with cement mortar 1:4, to brick masonry including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. ---- as per directions of engineer in-charge of work.

7.6752

-

2143.38

... More
KSRB15-4.4 Extra for providing and mixing waterproofing compound in cement plaster work at one kg per bag or in the proportion recommended by the manufacturers, forcement mortar 1:4, 18mm thick cost of materials complete as per specifications. ---- as per directions of engineer in-charge of work.

7.6752

-

65.09

... More
KSRB 2-2.1 : Earthwork excavation by manual means for foundation of buildings, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in ordinary soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. after breaking of clods complete as per specifications. specification. No. KBS 2.1(a) / 2.3.5 ---- as per directions of engineer in-charge of work.

1.6191

-

513.16

... More
KSRB 2-2.2 : Earthwork excavation by manual means for foundation of buildings, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in hard soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. after breaking of clods complete as per specifications. specification. No. KBS 2.1(b) / 2.3.5 ---- as per directions of engineer in-charge of work.

3.2382

-

1541.19

... More
KSRB 2-2.4 : Excavation by manual means for foundation of buildings, water supply & sanitary lines and electrical conduits etc. , either in pits or in trenches 1.50m and above in width, in soft rock /ordinary rock without blasting not exceeding 1.50mtrs in depth including stacking the excavated stuff clear from edges of excavation with lead upto 50mt including cost of explosives, labour, HOM complete as per specifications. specification. No. KBS 2.1Cl2.9.412.1812.19 ---- as per directions of engineer in-charge of work.

11.3337

-

17071.5

... More
KSRB 4-1.3 : Providing and laying in position plain cement concrete of mix 1:4:8 with OPC cement @ 180kgs, with 40mm and down size graded granite metal coarse aggregates @0.85cum and fine aggregates @ 0.57cum machine mixed, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, including cost of all materials, labour, HOM of machinery, curing complete as per specifications. Specification No. KBS 4.1, 4.2 ---- as per directions of engineer in-charge of work.

1.2722

-

7122.68

... More
KSRB 6-1.3 : Providing and constructing burnt brick masonry for basement and superstructure with approved quality of non-modular bricks of standard size of class designation 3.5Newton per sqmm with cement mortar1:6 including cost of materials, labour charges, scaffolding, curing complete as per specifications. Specification No. KBS 6.2 ---- as per directions of engineer in-charge of work.

4.554

-

29217.37

... More
KSRB 4.2.8: Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in ground floor level for roof slabs, staircase, lintles, and beams retaining walls, return walls, walls (any thickness) including attached plasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 ---- as per directions of engineer in-charge of work.

0.7985

-

5029.37

... More
KSRB 4-6.1 : Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for foundations, footings, bases of columns for mass concrete including cost of all materials, labour complete as per specificaitons. Specification No. KBS 4.6.2 ---- as per directions of engineer in-charge of work.

4.9936

-

1349.77

... More
KSRB 4-1.6 ; Providing and laying in position plain cement concrete of mix 1:2:4 with cement @ 240kgs, with 20mm and down size graded granite metal coarse aggregates @ 0.69 cum and fine aggregtes @ 0.459cum, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, plinth and cills, ncluding cost of all materials, labour, HOM of machinery, curing complete as per specifications. Specification No. KBS 4.1, 4.2 ---- as per directions of engineer in-charge of work.

0.432

-

2580.56

... More
KSRB15-3.11 : Providing 20mm thick cement plaster in single coat with cement mortar 1:4, to stone masonry & concrete surface including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. ---- as per directions of engineer in-charge of work.

22.6

-

6556.26

... More
KSRB15-4.5 Extra for providing and mixing waterproofing compound in cement plaster for stone masonry work at one kg per bag or in the proportion recommended by the manufacturers, for cement mortar 1:4, 20mm thick cost of materials complete as per specifications. ---- as per directions of engineer in-charge of work.

22.6

-

215.6

... More
KSRB 5-1.1 : Providing and constructing granite / trap / basalt rubble stone masonry in foundation with mud mortar (uncoursed), bond stones at two m. apart in each course including cost of materials, labour, curing complete as per specifications. KBS 5.1.12 ---- as per directions of engineer in-charge of work.

3.3062

-

8200.7

... More
KSRB 2.8 : Providing and Filling in foundation with granite / trap broken metal 100mm. and down size, with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift. complete as per specifications. specification. No. KBS ---- as per directions of engineer in-charge of work.

1.4266

-

3231.56

... More
KSRB13-3.6 : Providing and fixing in trenches galvanised / mild steel tubes (medium grade) 50mm dia nominal bore with all fittings ( earth work in trenches to be measured and paid for separately ) including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. Specification No.KBS 13.2.14 / 13.6 ---- as per directions of engineer in-charge of work.

150

-

61692

... More
KSRB13-7.1-4 : Providing and fixing in position 50mm nominal bore gun metal non-return valve horizontal type of approved make including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. Specification No.KBS 13.2.10 / 13.13 ---- as per directions of engineer in-charge of work.

2

-

2819.6

... More
KSRB 2-2.1 : Earthwork excavation by manual means for foundation of buildings, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in ordinary soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. after breaking of clods complete as per specifications. specification. No. KBS 2.1(a) / 2.3.5 ---- as per directions of engineer in-charge of work.

12.6802

-

4018.86

... More
KSRB 2-2.2 : Earthwork excavation by manual means for foundation of buildings, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in hard soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. after breaking of clods complete as per specifications. specification. No. KBS 2.1(b) / 2.3.5 ---- as per directions of engineer in-charge of work.

29.587

-

14081.64

... More
KSRB 2-4 : Refilling available earth around pipe lines, cables in layers not exceeding 20cms in depth, compacting each deposited layer by ramming after watering with lead upto 50m. and lift upto 1.5 m. including cost of all labour complete as per specifications. ---- as per directions of engineer in-charge of work.

42.2672

-

5421.19

... More
KSRB13-8.8 : Providing and fixing to wall, ceiling and floor, low density polyethylene pipes 6.00 kgf/sq.cm working pressure 90mm outside diameter with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. Specification No.KBS 13.2.15.1 / 13.9 ---- as per directions of engineer in-charge of work.

96

-

38668.8

... More
Constructing brick masonry inspection chamber 600x600mm, and 450mm depth, ( clear inside dimension ) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover withframe (light duty) 455x610mm internal dimensions, total weight of cover with frame to be not less than 38 kg ( weight of cover 23kg and weight of frame 15 kg) R.C.C. top slab with cement concrete M 15 with 20mm and downsize granite metal, foundation concrete M 5 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 600x600mm and 450mm depth ( clear inside dimension ) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover withframe (light duty) 600x600mm ---- as per directions of engineer in-charge of work.

12

-

107992.8

... More
KSRB 5-1.1 : Providing and constructing granite / trap / basalt rubble stone masonry in foundation with mud mortar (uncoursed), bond stones at two m. apart in each course including cost of materials, labour, curing complete as per specifications. KBS 5.1.12 ---- as per directions of engineer in-charge of work.

3.8394

-

9523.25

... More
KSRB 2.8 : Providing and Filling in foundation with granite / trap broken metal 100mm. and down size, with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift. complete as per specifications. specification. No. KBS ---- as per directions of engineer in-charge of work.

1.2798

-

2899.03

... More
Concealed Conduit System :Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary - 19/20mm dia 2mm thick ---- as per directions of engineer in-charge of work.

380

-

15200

... More
Concealed Conduit System :Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary - 25mm dia 2mm thick ---- as per directions of engineer in-charge of work.

240

-

12720

... More
Supplying And Fixing Metal Fan Box with Round Hook. ---- as per directions of engineer in-charge of work.

18

-

1530

... More
Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. - 19/20mm dia 2mm thick ---- as per directions of engineer in-charge of work.

160

-

8160

... More
Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. - 25mm dia 2mm thick ---- as per directions of engineer in-charge of work.

120

-

6480

... More
Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 1- Single Door II -Double Door Ill -Double Door - 4Way TP &N ---- as per directions of engineer in-charge of work.

2

-

5300

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 1-3Way ---- as per directions of engineer in-charge of work.

28

-

2660

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 4-5Way ---- as per directions of engineer in-charge of work.

6

-

630

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 6Way ---- as per directions of engineer in-charge of work.

4

-

500

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 8Way ---- as per directions of engineer in-charge of work.

24

-

3480

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 10-12Way ---- as per directions of engineer in-charge of work.

6

-

990

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 16-18Way ---- as per directions of engineer in-charge of work.

6

-

1080

... More
Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. - Short point upto 3Mtr from tapping point to out let via switch box ---- as per directions of engineer in-charge of work.

32

-

5120

... More
Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. - Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box ---- as per directions of engineer in-charge of work.

44

-

11000

... More
Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. - Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box ---- as per directions of engineer in-charge of work.

8

-

3000

... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.The following additional tests are compulsory either to be conducted at works or independent lab with witness by inspecting authority.Additional Tests for FRLS-Applicable Standard Oxygen Index -IS 694-1990, Clause 16.8 Temperature Index -IS 694-1990, Clause 16.13 Smoke Density -IS 694-1990, Clause 16.14 Test for Halogen Acid Gas evaluation -IS 694-1990, Clause 16.12 - 1.5 sqmm ---- as per directions of engineer in-charge of work.

720

-

14760

... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.The following additional tests are compulsory either to be conducted at works or independent lab with witness by inspecting authority.Additional Tests for FRLS-Applicable Standard Oxygen Index -IS 694-1990, Clause 16.8 Temperature Index -IS 694-1990, Clause 16.13 Smoke Density -IS 694-1990, Clause 16.14 Test for Halogen Acid Gas evaluation -IS 694-1990, Clause 16.12 - 2.5 sqmm ---- as per directions of engineer in-charge of work.

1450

-

46400

... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.The following additional tests are compulsory either to be conducted at works or independent lab with witness by inspecting authority.Additional Tests for FRLS-Applicable Standard Oxygen Index -IS 694-1990, Clause 16.8 Temperature Index -IS 694-1990, Clause 16.13 Smoke Density -IS 694-1990, Clause 16.14 Test for Halogen Acid Gas evaluation -IS 694-1990, Clause 16.12 - 4 sqmm ---- as per directions of engineer in-charge of work.

270

-

12150

... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.The following additional tests are compulsory either to be conducted at works or independent lab with witness by inspecting authority.Additional Tests for FRLS-Applicable Standard Oxygen Index -IS 694-1990, Clause 16.8 Temperature Index -IS 694-1990, Clause 16.13 Smoke Density -IS 694-1990, Clause 16.14 Test for Halogen Acid Gas evaluation -IS 694-1990, Clause 16.12 - 6 sqmm ---- as per directions of engineer in-charge of work.

90

-

6300

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 1 to 3 Module ---- as per directions of engineer in-charge of work.

24

-

2640

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 4 Module ---- as per directions of engineer in-charge of work.

6

-

750

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 6 Module ---- as per directions of engineer in-charge of work.

4

-

700

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 8 Module ---- as per directions of engineer in-charge of work.

24

-

4800

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 10-12 Module ---- as per directions of engineer in-charge of work.

6

-

1380

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 16-18 Module ---- as per directions of engineer in-charge of work.

4

-

1080

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. - 6Amps one way Switch ---- as per directions of engineer in-charge of work.

162

-

11340

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. - 6Amps Two way Switch ---- as per directions of engineer in-charge of work.

6

-

570

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. - 6Amps 3way socket ---- as per directions of engineer in-charge of work.

44

-

4620

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. - Stepped Fan Regulator. ---- as per directions of engineer in-charge of work.

18

-

5220

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. - 32Amps DP switch ---- as per directions of engineer in-charge of work.

4

-

728

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. - 6/16Amps universal socket ---- as per directions of engineer in-charge of work.

4

-

648

... More
Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- as per directions of engineer in-charge of work.

56

-

5936

... More
Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- as per directions of engineer in-charge of work.

4

-

4800

... More
Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / Watt, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 °C by resistance method at 245 Volts, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, watt& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty. - 48" Sweep 5 Star (1200mm) ---- as per directions of engineer in-charge of work.

18

-

52200

... More
Supplying & fixing of Surface mounting type retrofit type -LED tube ....... W comprising of LED linear source with CCT 6500 degree K, CRI> 70%. efficacy >80 lumen per watt, life> 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF > 0.95, power loss should < 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. - 18W-20W (T8) Polycarbonate/OPAL Acrylic Casing ---- as per directions of engineer in-charge of work.

36

-

15300

... More
Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI> 70%. efficacy > 100 lumen per watt, 120degree beam spread, life> 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF > 0.95, power loss should< 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. - LED modular down light 1 'x1' 34 -22watts ---- as per directions of engineer in-charge of work.

6

-

15852

... More
Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI> 70%. efficacy > 100 lumen per watt, 120degree beam spread, life> 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF > 0.95, power loss should< 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. - LED modular down light 2'x2' /1' X 4' 34 -36watt ---- as per directions of engineer in-charge of work.

1

-

5200

... More
Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI> 70%. efficacy >80 lumen per watt, life> 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF > 0.95, power loss should < 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. - 18W, 6500K ---- as per directions of engineer in-charge of work.

12

-

3060

... More
Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps. - On wall/ ceiling / Rafter / Girders ---- as per directions of engineer in-charge of work.

42

-

4620

... More
Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ---- as per directions of engineer in-charge of work.

18

-

2700

... More
Extra length of GI pipe of class B 19mm dia for down rod. ---- as per directions of engineer in-charge of work.

8

-

1280

... More
Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 amps. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. ---- as per directions of engineer in-charge of work.

4

-

1600

... More
Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. - Remote ---- as per directions of engineer in-charge of work.

1

-

1034

... More
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - 6-32Amps DP ---- as per directions of engineer in-charge of work.

8

-

7272

... More
Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V up to 300mA sensitivity on existing wood/panel board. - 16-25 Amps 2 pole ---- as per directions of engineer in-charge of work.

2

-

4600

... More
Supplying, erecting, testing & commissioning of OFF- LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with all accessories complete and Excluding batteries and wiring complete. - 5 KVA OFF LINE UPS Note: For item 10.2 batteries are required for backup power supply- 1) 1 KVA off line UPS one hour backup : 2 x 40 AH batteries. 2) 2 KVA off line UPS one hour backup : 3 x 80 AH batteries. 3) 5 KVA off line UPS one hour backup : 6 x 80 AH batteries. ---- as per directions of engineer in-charge of work.

1

-

37100

... More
Supplying, installation, testing & commissioning of 12Volts ..AH batteries in poly propylene container for D.G. sets. Low maintenance batteries, plate type. - 150 AH capacity ---- as per directions of engineer in-charge of work.

6

-

135000

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. - RJ45/I.O.outlet Cat-6 ---- as per directions of engineer in-charge of work.

12

-

2340

... More
Supplying and drawing UTP-CAT 6E LAN cable. ---- as per directions of engineer in-charge of work.

320

-

9280

... More
Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. - 2Pair ---- as per directions of engineer in-charge of work.

60

-

870

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. - TV/Telephone socket ---- as per directions of engineer in-charge of work.

3

-

237

... More
Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6. ---- as per directions of engineer in-charge of work.

60

-

2100

... More
Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. - 63Amps ---- as per directions of engineer in-charge of work.

3

-

681

... More
Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution) - 63Amps ---- as per directions of engineer in-charge of work.

1

-

5300

... More
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (Icu=lcs) THREE POLE FOUR POLE - 100Amps 25kA ---- as per directions of engineer in-charge of work.

1

-

6400

... More
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - 6-32Amps TPN ---- as per directions of engineer in-charge of work.

3

-

5145

... More
Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. ---- as per directions of engineer in-charge of work.

1

-

7700

... More
Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter ---- as per directions of engineer in-charge of work.

1

-

1185

... More
Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound. ---- as per directions of engineer in-charge of work.

3

-

1404

... More
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. ---- as per directions of engineer in-charge of work.

3

-

1290

... More
Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. - 100Amps 4x30x6mm Aluminium Strips ---- as per directions of engineer in-charge of work.

1.2

-

2460

... More
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. - 40x40x6mm ---- as per directions of engineer in-charge of work.

12

-

3060

... More
Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. - 16SWG ---- as per directions of engineer in-charge of work.

48000

-

16800

... More
Supplying PVC/GI flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely - 25mm ---- as per directions of engineer in-charge of work.

22

-

616

... More
Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. - 25x6mm Copper strip ---- as per directions of engineer in-charge of work.

1.2

-

1149.6

... More
Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. - 8 SWG Copper wire. ---- as per directions of engineer in-charge of work.

12

-

1260

... More
Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. ---- as per directions of engineer in-charge of work.

2

-

8300

... More
Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 - 3.5 core 25 sqmm ---- as per directions of engineer in-charge of work.

140

-

25200

... More
Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe/ stoneware pipe /on wall / on pole as required. In existing trench/duct. On wall/Structure - 25 sqmm to 75 sqmm ---- as per directions of engineer in-charge of work.

140

-

2170

... More
Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc. complete.(As per Civil SR KSRB 1-2, P-7) - In soil (hard) ---- as per directions of engineer in-charge of work.

120

-

12240

... More
Providing and laying in position 100mm dia stone ware pipe in existing trench. ---- as per directions of engineer in-charge of work.

5

-

1075

... More
Supplying and fixing LT cast Iron pot heads suitable for 1.1KV class UG cable filled with necessary bitumen/insulating compound complete with terminals, clamps, bolts, nuts and washers etc. - 35Sqmm ---- as per directions of engineer in-charge of work.

2

-

700

... More
Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) - 50mm dia ---- as per directions of engineer in-charge of work.

2

-

510

... More
Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. - 25 sqmm Long Barrel ---- as per directions of engineer in-charge of work.

16

-

320

... More
LED Street light : .Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT > 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire > IK08. Power Factor >0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency>1301m/w, nominal CRI >75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. - LED Streetlight 70 Watts ---- as per directions of engineer in-charge of work.

5

-

27400

... More
Supplying and Fixing of........mm dia class A GI pipe bracket up to 2 Mtrs long bent at suitable angle and fixing to this bracket 1x40/2x40 watts fluorescent tube street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires. - Using 25mm dia G.I.Pipe ---- as per directions of engineer in-charge of work.

5

-

3875

... More
Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990. - 3C X 2.5Sq.mm ---- as per directions of engineer in-charge of work.

180

-

17640

... More
Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 volts 1/3 phase motor upto 5 HP. ---- as per directions of engineer in-charge of work.

2

-

2760

... More
Supplying and fixing single phase preventer using necessary wires over an existing panel board suitable for motor up to 20 HP capacities. ---- as per directions of engineer in-charge of work.

1

-

745

... More
Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machineries like induction motor. ---- as per directions of engineer in-charge of work.

2

-

800

... More
Fixing a shunt capacitor of ... KVAR capacity with necessary clamps, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor. - 6 to 10 KVAR ---- as per directions of engineer in-charge of work.

2

-

382

... More
Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws. - 12"x12"x2" ---- as per directions of engineer in-charge of work.

2

-

300

... More
Supplying, fixing and wiring 0 to 600Volts 96x96mm AC Voltmeter on existing panel/wood board. ---- as per directions of engineer in-charge of work.

1

-

377

... More
Supplying, fixing and wiring 0 to 30amps Direct Reading AC analog type Ammeter ---- as per directions of engineer in-charge of work.

1

-

387

... More
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. ---- as per directions of engineer in-charge of work.

3

-

1290

... More
Supplying, installation, testing and commissioning of solar hot water heater comprising of high quality Evacuated Glass Tube (EGT) with absorber coating collector of size 58 x 1800 mm. Inner tank Material-Stainless steel 304-L Grade with Aluminium Stucco cladding made of High quality PUF insulation to minimizes heat loss and hold water Temperature upto 72 Hrs...with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. Fitted with Sacrificial Anode - 200 Liter capacity- 20 nos Tubes ---- as per directions of engineer in-charge of work.

1

-

46000

... More
Providing patti alround doors, windows, ventilators and for parapet & compound wall etc., with CM 1:3 & finished as per design and specifications including scaffolding etc., complete as per SR 02-03 Page No.135, item No.13.1 ---- as per directions of engineer in-charge of work.

108.36

-

1577.72

... More
Providing grooves in plastering of walls 2.5 to 4 cms vide and to the required depth as per design and finished in CM 1:3 including curing etc., complete Page No.212, S.No.36.38 ---- as per directions of engineer in-charge of work.

424.6

-

10555.56

... More
KSRB 4-9.2 :Providing TMT steel (cold, Twisted ) reinforced for RCC work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining member wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid ) including cost and conveyance of all materials, cost of labour and HOM of machinery, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Specification No.KBS 4.6.3. GF ---- as per directions of engineer in-charge of work.

13.42

-

1125212.38

... More
KSRB 4-9.2 :Providing TMT steel (cold, Twisted ) reinforced for RCC work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining member wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid ) including cost and conveyance of all materials, cost of labour and HOM of machinery, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Specification No.KBS 4.6.3. FF ---- as per directions of engineer in-charge of work.

3.58

-

303006.94

... More
Providing & fixing 65mm X65mm X6mm size MS angle iron ladder 45 cm wide with 25mm MS round bars at 25 cms c to c dully fixing drilling holes to full depth of angle and welding including fixing in ground with cc 1:3:6 proportion of size 0.6X0.45X0.23 mtrs bed and two coats of non-poisonous ant corrosive bitumin paint as directed ---- as per directions of engineer in-charge of work.

4.5

-

7996.5

... More
Providing and fixing Stainless Steel door fixtures of approved make and quality,including cost and conveyance of all materials, fixing labour charges and HOM of equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.(Refer general specification of tender document) For Main Doors ---- as per directions of engineer in-charge of work.

8.2

-

4920

... More
Providing and fixing Stainless Steel door fixtures of approved make and quality,including cost and conveyance of all materials, fixing labour charges and HOM of equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.(Refer general specification of tender document) For Internal Doors ---- as per directions of engineer in-charge of work.

15.99

-

6396

... More
Providing and fixing of Signage boards etc. complete with all lead, lifts, loading, unloading, scaffolding arrangement, cost and conveyance of all materials, labour, equipment, transportation charges, testing and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and as per the directions of the Engineer in-charge of the work. (including all taxes) ---- as per directions of engineer in-charge of work.

1

-

95000

... More
Providing and fixing in position Pillar cock of Jaquar/Hindware/Parry ware of approved quality 20mm nominal bore including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in-charge of work.

5

-

6250

... More
Providing and fixing in position Short body cock/tap of Jaquar/Hindware/Parry ware of approved quality 20mm nominal bore including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in-charge of work.

8

-

10000

... More
Providing and fixing in position Long body cock/tap of Jaquar/Hindware/Parry ware of approved quality 20mm nominal bore including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in-charge of work.

4

-

5400

... More
Providing and fixing in position Angle stop cock of Jaquar/Hindware/Parry ware of approved quality 20mm nominal bore including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in-charge of work.

11

-

13750

... More
Providing and fixing in position Two way bib cock of Jaquar/Hindware/Parry ware of approved quality 20mm nominal bore including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in-charge of work.

4

-

5400

... More
Providing and fixing in position Health faucet complete set of Jaquar/Hindware/Parry ware of approved quality 20mm nominal bore including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in-charge of work.

4

-

5400

... More
KSRB 4-9.2 :Providing TMT steel reinforced for RCC work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining member wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid ) cost of materials,labour,HOM of machinery complete as perspecification.Specification No.KBS 4.6.3.Sl.No-4.46/P-19. ---- as per directions of engineer in-charge of work.

0.07

-

5869.22

... More
Providing & fixing 60cms X 60 cms size MS inspection door with necessary MS frame made out of MS Angle of 50 mm X 50 mm X 6mm and MS shutters of 3 mm thickness with hinges on top and locking arrangements painting etc., complete for RCC Sump tank. Page No ---- as per directions of engineer in-charge of work.

1

-

1799

... More
KSRB 4-9.2 :Providing TMT steel reinforced for RCC work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining member wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid ) cost of materials,labour,HOM of machinery complete as perspecification.Specification No.KBS 4.6.3.Sl.No-4.46/P-19. ---- as per directions of engineer in-charge of work.

0.08

-

6707.67

... More
Geophysical investigation of site for sinking Bore well for supplying drinking water to the habitaion either through hand pump scheme mini water supply scheme or piped water supply scheme by vertical elctrical sounding by adopting vannur are schlumbergers method . including re connissance survey of geological formation. Geohidroligical investigation of existing ground water in the vicinity its quality. Quantity and acceptablity of the user. Indicating the location of site . Recommended depth of casing pipe required to seal the top un consolidated formation including extra depth of 1mt in consolidated formation for proper ceating of casing pipes. Depth of drilling corvering full depth of aquifer proposed to be tapped. probable yield and other information required for safe drinking and harnessing including transportation of instrument and accessories to work site. engaging techinical personnel and lobour required etc complete. ---- as per directions of engineer in-charge of work.

1

-

1882

... More
Sinking the Bore well of the 150mm dia clear using super fast hydrolic ring of capacity 250PSIG & above 900CFM& above in all strata including over burden up to 20mm. Fixing of casing pipes ,collears and cap with ncessory cutting threding and welding including transpotation of ring and supporting vehicle. Crew charges and cost of consumables etc complete including yield testing at that final depth with a minimum working of compressor for 1 hour (excluding cost of casing pipes,collars, and cap. etc ) i) Up to 0.00 to 50.00 mtrs ---- as per directions of engineer in-charge of work.

50

-

13500

... More
Sinking the Bore well of the 150mm dia clear using super fast hydrolic ring of capacity 250PSIG & above 900CFM& above in all strata including over burden up to 20mm. Fixing of casing pipes ,collears and cap with ncessory cutting threding and welding including transpotation of ring and supporting vehicle. Crew charges and cost of consumables etc complete including yield testing at that final depth with a minimum working of compressor for 1 hour (excluding cost of casing pipes,collars, and cap. etc ) ii) Up to 50.00 to 100.00 mtrs ---- as per directions of engineer in-charge of work.

50

-

18500

... More
Sinking the Bore well of the 150mm dia clear using super fast hydrolic ring of capacity 250PSIG & above 900CFM& above in all strata including over burden up to 20mm. Fixing of casing pipes ,collears and cap with ncessory cutting threding and welding including transpotation of ring and supporting vehicle. Crew charges and cost of consumables etc complete including yield testing at that final depth with a minimum working of compressor for 1 hour (excluding cost of casing pipes,collars, and cap. etc ) i) Up to 100.00 to 150.00 mtrs ---- as per directions of engineer in-charge of work.

20

-

7900

... More
Providing & Fixing ISI mark 150mm nominal Bore medium Black ERW casing pipe B Class resistance continues welded mild steel tubes mediuam grade containing IS 1239/1990 (parts) ammendaments 1-5 etc and fitted with sockets and other end with plastick protect ---- as per directions of engineer in-charge of work.

20

-

8620

... More
Providing & Fixing MS cap. ---- as per directions of engineer in-charge of work.

1

-

85

... More
Supplying and fixing cast Aluminium round or oblong type bulk head fitting with GI wire guard, glass cover with 15Watts 230V CFL lamp as required ---- as per directions of engineer in-charge of work.

2

-

1904

... More
Supplying of Single Phase Open well Mono sub pump set 1.5 HP suitable for operation on 230 volts Single phase AC supply Make- Using group "A" materials. And as per the directions of engineer incharge of the work. ---- as per directions of engineer in-charge of work.

1

-

10867

... More
Supplying and Delivery at Site 2 HP 20 Stage single phase 4 inch/100mm Submersible Pump set of approved make ISI with Motor. Suitable for operation of three Phase 50 HZ 440 Volts A.C supply fitted with required accessories complete as per the approved rate Make - Make:Kirloskar/Calama/Lubi/Atlanta/Texmo/Suguna and as per the directions of Engineer in charge of the work. ---- as per directions of engineer in-charge of work.

1

-

19579

... More
Providing and fixing to wall, ceiling and floor high density polyethylene pipes 6.00 kgf/sq.cm working pressure of outside diameter raising mains & exposed distribution pipes with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor,, including cost of all materials, labour charges, HOM and testing complete as per specifications. 40mm dia. ---- as per directions of engineer in-charge of work.

160

-

41920

... More
Supplying, installation and erection of Gate valve of 50 mm dia. ---- as per directions of engineer in-charge of work.

1

-

1800

... More
Supplying, installation and erection of Non Return valve of 50 mm dia. ---- as per directions of engineer in-charge of work.

1

-

1800

... More
Supplying, installation and erection of Borewell cap and clamp set. ---- as per directions of engineer in-charge of work.

1

-

1800

... More
Providing and fixing chlorinated poly vinyl chloride (CPVC ) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all C P V C plain and brass threaded fittings, including fixing the pipe with clamp at 1.00 mtrs spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete ( external work) a) for 40mm nominal OD Pipe ---- as per directions of engineer in-charge of work.

20

-

5840

... More
Providing and fixing chlorinated poly vinyl chloride (CPVC ) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all C P V C plain and brass threaded fittings, including fixing the pipe with clamp at 1.00 mtrs spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete ( external work) a) for 25mm diaMake- group "A" materials. And as per the directions of engineer incharge of the work. ---- as per directions of engineer in-charge of work.

20

-

3300

... More
"Providing and fixing chlorinated poly vinyl chloride (CPVC ) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all C P V C plain and brass threaded fittings, including fixing the pipe with clamp at 1.00 mtrs spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete ( external work) a) for 20mm nominal OD Pipe Make- group ""A"" materials. And as per the directions of engineer incharge of the work. " ---- as per directions of engineer in-charge of work.

20

-

3580

... More
Providing and fixing in position brass Gate Valve with C.I. wheel of app. Quality (Screw End) 40mm nominal bore including cost of all materials, labour and HOM of equipments with all leed complete as per specifications. a) for 40mm dia nominal ---- as per directions of engineer in-charge of work.

2

-

2226

... More
Providing and fixing in position brass Gate Valve with C.I. wheel of app. Quality (Screw End) 40mm nominal bore including cost of all materials, labour and HOM of equipments with all leed complete as per pecifications. a) for 25 mm dia nominal Make- group "A" materials. And as per the directions of engineer incharge of the work. ---- as per directions of engineer in-charge of work.

2

-

1014



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.