Karnataka State Police Housing And Infrastructure Development Corporation Limited Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Karnataka State Police Housing And Infrastructure Development Corporation Limited - KSPHCL Tender

Civil And Construction
Building Construction
Opening Date9 Oct 2024
Closing Date24 Oct 2024
Tender Amount₹ 1,45,48,547.23 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Vol_I_15_2_1_2 - Providing and laying in position plain cement concrete Mix 1 4 8 M5 Using 40 mm and down size graded crushed coarse aggregates for levelling course for all works in foundation. The graniteand trapand basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.

55.73

5833

325124.3616

... More
Vol_I_65_2_2_3 - Providing and laying in position Reinforced cement concrete M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates for all Foundation works. The graniteand trapand basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.

50.46

6721

339185.0556

... More
Vol_I_16_2_5_2 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The graniteand trapand basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates a Ground Floor

15.9

11982

190515.231

... More
Vol_I_16_2_5_2 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The graniteand trapand basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates b First Floor

7.7

12101

93184.707

... More
Vol_I_16_2_5_2 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The graniteand trapand basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates c Second Floor

5.33

12221

65141.8209

... More
Vol_II_9_5_3 - Providing Coursed rubble masonry second sort with hard stone in foundation and plinth with Cement mortar 1 6 1 cement 6 coarse sand

3.22

6391

20579.503

... More
Vol_I_7_1_9 - Filling available excavated earth excluding rock in trenches, plinth, sides of foundations and other similar works etc. in layers not exceed- ing 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

195.58

273

53585.0084

... More
Vol_I__1_11 - Filling approved excavated earth excluding rock in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

220.97

445

98550.4103

... More
Vol_II_16_2_4_3 - Providing and laying in position Reinforced cement concrete M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The graniteand trapand basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. for Plinth beam

22.6

9789

221234.112

... More
Vol_II_14_6_8 - Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1 6 1 cement 6 coarse sand including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work.a Ground Floor

84.94

8208

697193.4658

... More
Vol_II_14_6_8 - Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1 6 1 cement 6 coarse sand including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. b First Floor

59.78

8290

495585.167

... More
Vol_II_14_6_8 - Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1 6 1 cement 6 coarse sand including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. c Second Floor

40.95

8372

342842.8185

... More
Vol_II_14_6_15_15_6_16 - Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1 4 1 cement 4 coarse sand including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. a Ground Floor

86.2

1161

100150.608

... More
Vol_II_14_6_15_15_6_16 - Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1 4 1 cement 4 coarse sand including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. b First Floor

133.88

1173

157102.8248

... More
Vol_II_14_6_15_15_6_16 - Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1 4 1 cement 4 coarse sand including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. c Second Floor

98.01

1185

116149.6908

... More
Vol_I_15_2_1_4 - Providing and laying in position plain cement concrete Mix 1 3 6 M10 Using 20 mm and down size graded crushed coarse aggregates for levelling course for all works in foundation. The graniteand trapand basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Ground Floor

3.58

6595

23612.3196

... More
Vol_I_15_2_1_4 - Providing and laying in position plain cement concrete Mix 1 3 6 M10 Using 20 mm and down size graded crushed coarse aggregates for levelling course for all works in foundation. The graniteand trapand basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. First Floor

3.41

6661

22715.9537

... More
Vol_I_15_2_1_4 - Providing and laying in position plain cement concrete Mix 1 3 6 M10 Using 20 mm and down size graded crushed coarse aggregates for levelling course for all works in foundation. The graniteand trapand basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Second Floor

2.51

6727

16886.1003

... More
Vol_I_17_2_5_2 - Providing and laying in position Reinforced cement concrete M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates, for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The graniteand trapand basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. for Ground floor I Lintels

7.15

11277

80632.409

... More
Vol_I_17_2_5_2 - Providing and laying in position Reinforced cement concrete M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates, for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The graniteand trapand basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. for Ground Floor IIRoof Beams

17.43

11277

196562.6418

... More
Vol_I_17_2_5_2 - Providing and laying in position Reinforced cement concrete M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates, for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The graniteand trapand basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. for Staircase, Ground floor

3.08

10572

32563.1152

... More
Vol_I_17_2_5_2 - Providing and laying in position Reinforced cement concrete M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates, for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The graniteand trapand basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. for First FLoor I Lintels

8.27

11390

94195.6308

... More
Vol_I_17_2_5_2 - Providing and laying in position Reinforced cement concrete M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates, for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The graniteand trapand basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. for First Floor IIRoof Beams

13.16

11390

149892.9264

... More
Vol_I_17_2_5_2 - Providing and laying in position Reinforced cement concrete M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates, for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The graniteand trapand basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. for Staircase, First floor

3.08

10678

32888.7328

... More
Vol_I_17_2_5_2 - Providing and laying in position Reinforced cement concrete M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates, for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The graniteand trapand basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. for Second FLoor I Lintels

5.5

11502

63265.455

... More
Vol_I_17_2_5_2 - Providing and laying in position Reinforced cement concrete M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates, for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The graniteand trapand basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. for Second Floor IIRoof Beams

6.47

11502

74423.1807

... More
SR_2018_19_154_21 - KSRB 4-2.12 Extra for providing throating or drip moulding to R.C.C. chajja with plastering labour charges only as per specifications. Specification No. KBS a Ground Floor

46

33

1563.54

... More
SR_2018_19_154_21 - KSRB 4-2.12 Extra for providing throating or drip moulding to R.C.C. chajja with plastering labour charges only as per specifications. Specification No. KBS b First Floor

53.3

33

1811.667

... More
SR_2018_19_154_21 - KSRB 4-2.12 Extra for providing throating or drip moulding to R.C.C. chajja with plastering labour charges only as per specifications. Specification No. KBS c Second Floor

27.9

33

948.321

... More
vol_II_8_16a - KSRB 4-5 Providing lath plaster with cement mortar 1 3, 5cms thick with 6mm dia mild steel bars at 20cms c to c both horizontally and vertially fixing chicken mesh for drop chajja, facia, backing to cup boards including cost of all materials, labour, providing and removing from work HOM of machineries, curing, complete as per specifications. Specification No. KBS b First Floor

35.25

1275

44948.685

... More
SR_2018_19_204_55 - KSRB 4-5 Providing lath plaster with cement mortar 1 3, 5cms thick with 6mm dia mild steel bars at 20cms c to c both horizontally and vertially fixing chicken mesh for drop chajja, facia, backing to cup boards including cost of all materials, labour, providing and removing from work HOM of machineries, curing, complete as per specifications. Specification No. KBS a Ground Floor

7.2

638

4597.92

... More
SR_2018_19_204_55 - KSRB 4-5 Providing lath plaster with cement mortar 1 3, 5cms thick with 6mm dia mild steel bars at 20cms c to c both horizontally and vertially fixing chicken mesh for drop chajja, facia, backing to cup boards including cost of all materials, labour, providing and removing from work HOM of machineries, curing, complete as per specifications. Specification No. KBS b First Floor

17.1

638

10920.06

... More
SR_2018_19_204_55 - KSRB 4-5 Providing lath plaster with cement mortar 1 3, 5cms thick with 6mm dia mild steel bars at 20cms c to c both horizontally and vertially fixing chicken mesh for drop chajja, facia, backing to cup boards including cost of all materials, labour, providing and removing from work HOM of machineries, curing, complete as per specifications. Specification No. KBS c Second Floor

4.68

638

2988.648

... More
SR_2018_19_204_54 - Providing RCC loft atta 7.5cms thick withcement concrete design mix M25 using clean garnite or trap jelly of 20mm and down size with necessary rienforcement at 20cms centre to centre as per design including form work,centering ,curing,etc., complete inclusive of cost of steel and fabrication charges a Ground Floor

12.6

445

5619.474

... More
SR_2018_19_204_54 - Providing RCC loft atta 7.5cms thick withcement concrete design mix M25 using clean garnite or trap jelly of 20mm and down size with necessary rienforcement at 20cms centre to centre as per design including form work,centering ,curing,etc., complete inclusive of cost of steel and fabrication charges b First Floor

12.44

445

5548.1156

... More
SR_2018_19_204_54 - Providing RCC loft atta 7.5cms thick withcement concrete design mix M25 using clean garnite or trap jelly of 20mm and down size with necessary rienforcement at 20cms centre to centre as per design including form work,centering ,curing,etc., complete inclusive of cost of steel and fabrication chargesc Second Floor

2.34

445

1043.6166

... More
Vol_I_17_2_5_2 - Providing and laying in position Reinforced cement concrete M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates, for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The graniteand trapand basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. for Roof slab a Ground Floor

32.8

10572

346776.032

... More
Vol_I_17_2_5_2 - Providing and laying in position Reinforced cement concrete M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates, for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The graniteand trapand basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. for Roof slab b First Floor

33.15

10678

353981.004

... More
Vol_I_17_2_5_2 - Providing and laying in position Reinforced cement concrete M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates, for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The graniteand trapand basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. for Roof slab c Second Floor

14.37

10783

154964.3556

... More
Vol_II_42_8_9 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1 5 1 cement 5 coarse sand and a top layer 6 mm thick cement plaster with cement mortar 1 3 1 cement 3 coarse sand finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. a Ground Floor

314.3

396

124635.665

... More
Vol_II_42_8_9 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1 5 1 cement 5 coarse sand and a top layer 6 mm thick cement plaster with cement mortar 1 3 1 cement 3 coarse sand finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. b First Floor

245.07

400

98155.4364

... More
Vol_II_42_8_9 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1 5 1 cement 5 coarse sand and a top layer 6 mm thick cement plaster with cement mortar 1 3 1 cement 3 coarse sand finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. c Second Floor

321.21

404

129923.0208

... More
Vol_II_41_8_1_1 - Providing 12 mm cement plaster with cement mortar 1 4 1 cement 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. for inside walls a Ground Floor

700.95

262

184104.5175

... More
Vol_II_41_8_1_1 - Providing 12 mm cement plaster with cement mortar 1 4 1 cement 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. for inside walls b First Floor

678.26

265

179928.8128

... More
Vol_II_41_8_1_1 - Providing 12 mm cement plaster with cement mortar 1 4 1 cement 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. for inside walls c Second Floor

248.45

267

66559.755

... More
Vol_II_42_8_10 - Providing 6 mm cement plaster with cement mortar 1 3 1 cement 3 fine sand on concrete surface and ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. a Ground Floor

229.93

217

49970.6869

... More
Vol_II_42_8_10 - Providing 6 mm cement plaster with cement mortar 1 3 1 cement 3 fine sand on concrete surface and ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. b First Floor

209.17

219

45912.815

... More
Vol_II_42_8_10 - Providing 6 mm cement plaster with cement mortar 1 3 1 cement 3 fine sand on concrete surface and ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. c Second Floor

85.26

221

18900.4368

... More
Vol_II_41_8_2_1 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1 6 1 cement 4 fine sand including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. a Ground Floor

79.8

303

24247.23

... More
Vol_II_41_8_2_1 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1 6 1 cement 4 fine sand including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. b First Floor

78.86

306

24201.3454

... More
Vol_II_41_8_2_1 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1 6 1 cement 4 fine sand including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. c Second Floor

110.29

309

34182.1797

... More
Vol_II_63_9_24_ - Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm average thick base of cement mortar 1 4 1 cement 4 coarse sand laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. a Ground Floor

44.61

2937

131044.5516

... More
Vol_II_63_9_24_ - Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm average thick base of cement mortar 1 4 1 cement 4 coarse sand laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. b First Floor

24.42

2966

72452.6748

... More
Vol_II_61_9_17_2 - Providing and laying Vitrified tiles in different sizes thickness to be specified by manufacturer, with water absorption less than 0.08 and conforming to I.S. 15622, of approved make, in all colours and shade, over 12 mm thick bed of cement mortar 1 3 1 cement 3 coarse sand, jointing with grey cement slurry 3.3 kgand m2 including grouting the joint with white cement and matching pigments etc. complete. Size of Tile 600x600 mm a Ground Floor

184.51

1210

223303.2275

... More
Vol_II_61_9_17_2 - Providing and laying Vitrified tiles in different sizes thickness to be specified by manufacturer, with water absorption less than 0.08 and conforming to I.S. 15622, of approved make, in all colours and shade, over 12 mm thick bed of cement mortar 1 3 1 cement 3 coarse sand, jointing with grey cement slurry 3.3 kgand m2 including grouting the joint with white cement and matching pigments etc. complete. Size of Tile 600x600 mm b First Floor

166.88

1222

203985.768

... More
Vol_II_61_9_17_2 - Providing and laying Vitrified tiles in different sizes thickness to be specified by manufacturer, with water absorption less than 0.08 and conforming to I.S. 15622, of approved make, in all colours and shade, over 12 mm thick bed of cement mortar 1 3 1 cement 3 coarse sand, jointing with grey cement slurry 3.3 kgand m2 including grouting the joint with white cement and matching pigments etc. complete. Size of Tile 600x600 mm c Second Floor

43.73

1234

53982.9358

... More
Vol_II_60_9_11__61_9_14 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm thickness to be specified by the manufacturer, of 1st quality conforming to IS 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1 4 1 Cement 4 Coarse sand, jointing with grey cement slurry 3.3 kgand m2 including pointing the joints with white cement and matching pigments etc., complete. for Ceramic Tiles of size 30x30cms Fixing glazedand Ceramicand Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive Water based conforming to IS 15477, in average 3mm thickness. a Ground Floor

21.16

1279

27069.1416

... More
Vol_II_60_9_11__61_9_14 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm thickness to be specified by the manufacturer, of 1st quality conforming to IS 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1 4 1 Cement 4 Coarse sand, jointing with grey cement slurry 3.3 kgand m2 including pointing the joints with white cement and matching pigments etc., complete. for Ceramic Tiles of size 30x30cms Fixing glazedand Ceramicand Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive Water based conforming to IS 15477, in average 3mm thickness. b First Floor

19

1292

24548.95

... More
Vol_II_60_9_11__61_9_14 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm thickness to be specified by the manufacturer, of 1st quality conforming to IS 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1 4 1 Cement 4 Coarse sand, jointing with grey cement slurry 3.3 kgand m2 including pointing the joints with white cement and matching pigments etc., complete. for Ceramic Tiles of size 30x30cms Fixing glazedand Ceramicand Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive Water based conforming to IS 15477, in average 3mm thickness. c Second Floor

27.72

1304

36170.442

... More
Vol_II_65_9_39 - Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1 3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. a Ground Floor

79.8

1492

119099.106

... More
Vol_II_65_9_39 - Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1 3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. b First Floor

77.42

1507

116702.1338

... More
Vol_II_65_9_39 - Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1 3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. c Second Floor

110.29

1522

167896.6728

... More
Vol_II_85_11_34B - Providing and fixing M.S. grills of required pattern in frames of win- dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings and wooden frames with rawl plugs screws etc.

2636.92

188

497033.0508

... More
Vol_II_83_11_28 - Providing and fixing stainless steel Grade 304 railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature wherever required and fitting the same with necessary stainless steel nuts and bolts complete, iand c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc. including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.

25.02

581

14560.389

... More
Vol_II_99_12_11 - Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves excluding cost of cement concrete and side clamps, but including cost of materials, labour, usage charges complete as per specifications. a Ground Floor

0.7

142216

99551.354

... More
Vol_II_99_12_11 - Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves excluding cost of cement concrete and side clamps, but including cost of materials, labour, usage charges complete as per specifications. b First Floor

0.69

143638

99110.4822

... More
Vol_II_99_12_11 - Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves excluding cost of cement concrete and side clamps, but including cost of materials, labour, usage charges complete as per specifications. c Second Floor

0.57

145060

82684.5078

... More
Vol_II_105_12_51 - Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1 3 6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.

37

1046

38719.76

... More
Vol_II_106_12_57_4 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets core veneer hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 part-I 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side Teak a Ground Floor

11.99

4667

55968.8404

... More
Vol_II_106_12_57_4 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets core veneer hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 part-I 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side Teak b First Floor

11.99

4714

56528.5336

... More
Vol_II_106_12_57_4 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets core veneer hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 part-I 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side Teak c Second Floor

6.15

4761

29282.118

... More
Vol_II_106_12_57_1 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets core veneer hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 part-I 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side Teak a Ground Floor

7.18

4164

29899.6022

... More
Vol_II_106_12_57_1 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets core veneer hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 part-I 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side Teak b First Floor

7.18

4205

30198.5774

... More
Vol_II_106_12_57_1 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets core veneer hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 part-I 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side Teak c Second Floor

11.48

4247

48762.2184

... More
Vol_II_111_12_90 - Providing and fixing of 3 track x 2-panel sliding windows made out of multi chambered UPVC Matching to RAL-9016 sections and with minimum TiO2Titanium Dioxide at 6PHR with TPEThermo Plastic Elastomer and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardwareand Multi point locking system with touch lock. Wall thickness of frame and sash shall be of 2mm-2.5mm. Maximum possible size -2419mm x 2200mm. The cost is inclusive of all fixtures and separate charges for minor TandP's shall not be made

98.47

6936

682989.8894

... More
Vol_II_46_8_30 - Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work Two coats applied 1.43 ltrand 10 m² over and including priming coat of exterior primer applied 2.20 kgand 10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. a Ground Floor

447.2

179

80147.184

... More
Vol_II_46_8_30 - Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work Two coats applied 1.43 ltrand 10 m² over and including priming coat of exterior primer applied 2.20 kgand 10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. b First Floor

335.31

181

60694.4631

... More
Vol_II_46_8_30 - Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work Two coats applied 1.43 ltrand 10 m² over and including priming coat of exterior primer applied 2.20 kgand 10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. c Second Floor

359.37

182

65692.836

... More
Vol_II_50_8_51 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. a Ground Floor

970.48

103

99959.44

... More
Vol_II_50_8_51 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. b First Floor

946.52

104

98466.4756

... More
Vol_II_50_8_51 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. c Second Floor

420.51

105

44178.7806

... More
Vol_II_48_8_39 - Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. for walls and ceiling a Ground Floor

970.48

130

126948.4888

... More
Vol_II_48_8_39 - Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. for walls and ceiling b First Floor

946.52

132

125054.2224

... More
Vol_II_48_8_39 - Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. for walls and ceiling c Second Floor

420.51

133

56108.6493

... More
Vol_I1_18_2_11a - Supplying, fitting and placing TMT FE 550 and 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapingand welding joints, tying with binding wire and soft annealed steel wire and other ancilary operations complete as per drawing and technical specification a Buildings Ground Floor

13.68

92140

1260484.9128

... More
Vol_I1_18_2_11a - Supplying, fitting and placing TMT FE 550 and 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapingand welding joints, tying with binding wire and soft annealed steel wire and other ancilary operations complete as per drawing and technical specification a Buildings b First Floor

6.99

93062

650504.2188

... More
Vol_I1_18_2_11a - Supplying, fitting and placing TMT FE 550 and 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapingand welding joints, tying with binding wire and soft annealed steel wire and other ancilary operations complete as per drawing and technical specification a Buildings c Second Floor

3.33

93983

312965.1216

... More
vol_II_50_8_55_1 - Applying priming coats with primer of approved brand and manufacture, having low VOC Volatile Organic Compound content. With ready mixed pink or grey primer on wood work hard and soft wood having VOC content less than 50 gramsand litre as per specifications and as per directions of Engineer in charge.

67.16

57

3873.7888

... More
Vol_II_488_40 - Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.

67.16

118

7955.102

... More
Vol_II_478_34_3 - Applying priming coat With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised ironand steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.

139.27

51

7172.405

... More
Vol_II_488_40 - Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.

139.27

118

16496.5315

... More
Vol_III,_538_3 - Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade English and Roman

6750

1

11137.5

... More
1178_16_2 - KSRB 15.8.2 Providing and fixing plaster mesh 150mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. length of mesh only be measured for payment

450

39

17613

... More
Vol_II_64_9_25 - Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of CandD waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.

15.5

824

12772

... More
8_7954_Vol_2 - Providing grooves in plastering of walls 2.5 to 4 cms vide and to the required depth as per design and finished in CM 1 3 including curing etc., complete as per Specification.

984

53

52703.04

... More
NSR1 - Plantation of fruit trees

10

50

500

... More
vol_I_1_6_1 - Earth work excavation for pipelines and cables by Manual means upto 600 mm trench width as per drawing and technical specifications including setting out shoring strutting barricading caution lights removal of stumps and other deleterious matter including dressing of excavated surfaces disposing off or leveling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m Filling available excavated earth excluding rock in trenches plinth sides of foundations etc in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming and watering and lift upto 15 m including cost of labour tools usage and other appurtenances required to complete the work In all kinds of soils Depth upto 150 m

27.9

561

15661.665

... More
Vol_II_13_33_3 - Providing and fixing chorinated poly vinyl Chloride CPVC pipes 25 mm nominal OD pipe conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. Concealed work including cutting chases and making good walls

20

304

6097.6

... More
Vol_II_13_33_4 - Providing and fixing Chorinated Poly Venyl Chloride CPVC pipes 32mm nominal OD pipes confirming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings this including jointing of pipes and fittings with one step solvent cement trenching refilling and testing of joints complete external work

25

383

9579

... More
Vol_II_13_33_5 - Providing and fixing Chorinated Poly Venyl Chloride CPVC pipes 40mm nominal OD pipes confirming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings this including jointing of pipes and fittings with one step solvent cement trenching refilling and testing of joints complete external work

50

491

24565.5

... More
Vol_II_13_33_6 - Providing and fixing Chorinated Poly Venyl Chloride CPVC pipes 50mm nominal OD pipes confirming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings this including jointing of pipes and fittings with one step solvent cement trenching refilling and testing of joints complete external work

50

742

37131.5

... More
Vol_II_13_64_1 - Providing and fixing Sewer SWR pipes including all fittings This includes jointing of pipes and fittings with one step solvent cement trenching refilling and testing of joints complete as per direction of Engineer in Charge75mm nominal dia pipes

20

297

5953.4

... More
Vol_II_13_64_2 - Providing and fixing Sewer SWR pipes including all fittings This includes jointing of pipes and fittings with one step solvent cement trenching refilling and testing of joints complete as per direction of Engineer in Charge 110mm nominal dia pipes

64

396

25379.2

... More
Vol_II_13_64_3 - Providing and fixing Sewer SWR pipes including all fittings This includes jointing of pipes and fittings with one step solvent cement trenching refilling and testing of joints complete as per direction of Engineer in Charge 150mm nominal dia pipes

40

791

31641.6

... More
NSR_2 - Providing and fixing in position Jaquar and Hindware and Parry ware or equivalent Short body cockand tap of approved quality 20mm nominal bore including cost of all materials labour and HOM of equipments with all lead lift loading unloading and HOM charges etc complete as per specifications and directions of the Engineer in charge of work

6

1250

7500

... More
NSR_3 - Providing and fixing in position Jaquar and Hindware and Parry ware or equivalent Long body cockand tap of approved quality 20mm nominal bore including cost of all materials labour and HOM of equipments with all lead lift loading unloading and HOM charges etc complete as per specifications and directions of the Engineer in charge of work

4

1350

5400

... More
NSR4 - Providing and fixing in position Jaquar and Hindware and Parry ware or equivalent Angle stop cock of approved quality 20mm nominal bore including cost of all materials, labour and HOM of equipments with all lead, lift, loading, unloading and HOM charges etc., complete as per specifications. and directions of the Engineer-in-charge of work.

11

1250

13750

... More
NSR5 - Providing and fixing in position Jaquar and Hindware and Parry ware or equivalent Two way bib cock of approved quality 20mm nominal bore including cost of all materials, labour and HOM of equipments with all lead, lift, loading, unloading and HOM charges etc., complete as per specifications. and directions of the Engineer-in-charge of work.

4

1350

5400

... More
NSR6 - Providing and fixing in position Jaquar and Hindware and Parry ware or equivalent Pillar cock of approved quality 20mm nominal bore including cost of all materials, labour and HOM of equipments with all lead, lift, loading, unloading and HOM charges etc., complete as per specifications. and directions of the Engineer-in-charge of work.

4

1250

5000

... More
NSR7 - Providing and fixing in position Jaquar and Hindware and Parry ware or equivalent Health faucet complete set of approved quality 20mm nominal bore including cost of all materials, labour and HOM of equipments with all lead, lift, loading, unloading and HOM charges etc., complete as per specifications. and directions of the Engineer-in-charge of work.

7

1350

9450

... More
Vol_II_13_34 - KSRB 13-11.1 Providing and placing on terrace,polythene water storage tanks as per IS 12701 1996 manhole lid and suitable locking arrangements,making holes of suitable diameter for inlet,outlet and over flow pipes,including cost of allmaterials,labour,transport charges,HOM and testing complete as per specifications. For 1000 litr capacity Specification No.KBS 13.22

2000

9

18540

... More
Vol_II_126_13_55 - Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1 4 1 cement 4 coarse sand C.I. cover with frame light duty 600X850 mm internal dimensions, total weight of cover with frame to be not less than 38 kg weight of cover 23 kg and weight of frame 15 kg, R.C.C. top slab with 1 1.5 3 mix 1 cement 1.5 fine sand 3 graded stone aggregate 20 mm nominal size, foundation concrete 1 5 10 1 cement 5 line sand 10 graded stone aggregate 40 mm nominal size, inside plastering 12 mm thick with cement mortar 1 3 1 cement 3 coarse sand, finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets With common burnt clay non modular bricks of class designation 3.5

2

7623

15246.06

... More
Vol_II_126_13_53 - Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1 4 1 cement 4 coarse sand C.I. cover with frame light duty 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg weight of cover 23 kg and weight of frame 15 kg, R.C.C. top slab with 1 1.5 3 mix 1 cement 1.5 fine sand 3 graded stone aggregate 20 mm nominal size, foundation concrete 1 5 10 1 cement 5 fine sand 10 graded stone aggregate 40 mm nominal size, inside plastering 12 mm thick with cement mortar 1 3 1 cement 3 coarse sand, finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design Inside dimensions 455x610 mm and 45 cm deep for single pipe line With common burnt clay non modular bricks of class designation 3.5

4

5811

23245.04

... More
Vol_II_13_4_2 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality screwed end 32mm dia

1

615

615.94

... More
Vol_II_13_4_3 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality screwed end 40 mm dia

1

723

723.06

... More
Vol_II_14_23 - Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively.

7

1188

8320.34

... More
Vol_II_14_1_1 - White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests

4

5030

20122.08

... More
Vol_II_14_3_1 - Providing and fixing white vitreous china pedestal type water closet European type with seat and lid, 10 litre low level white vitreous china flushing cistern and C.P. flush bend with fittings and C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid

8

6156

49250.48

... More
Vol_II_14_7_5 - White Vitreous China Angle back wash basin size 600 x 480 mm with single 15mm C.P. brass pillar tap

11

2637

29016.13

... More
Vol_V_52_794 - HDPE Manhole 1.2 M dia 1m depth

1

8549

8549

... More
Vol_II_14_31 - Providing and fixing 600x450 mm beveled edge mirror of superior glass of approved quality complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

11

1256

13822.6

... More
Vol_II_14_40_2 - Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.

11

510

5619.68

... More
NSR8 - Providing 10cms dia PVC cowl with cap of approved 1 st quality and make conforming to ISI specifications and fixing in position as directed Rate includes cost of materials fixtures including conveyance charges to the work spot

3

50

150

... More
SR_18_19_9012_111 - Providing NPand CP waste unions for 32mm dia conforming to ISI specifications and fixing them in position as per directions including cost of materials, fixtures and conveyance to work spot etc., complete.

5

154

772.5

... More
Vol_I_13_59 - Providing and fixing PVC S.W.R Nahani Trap 10cms x 10cms with all fitting arrangements and all necessary accessories complete

10

226

2266

... More
SR_18_19_9713_81_1 - Providing NPand CP waste unions for 32mm dia conforming to ISI specifications and fixing them in position as per directions including cost of materials, fixtures and conveyance to work spot etc., complete.

5

123

618

... More
SR_18_19_26937_36_1 - Wall bores in size stone masonry upto 45 cm thick.

10

312

3120.9

... More
SR_18_19_26937_35 - Wall bores in Brick masonry upto 45 cm thick.

10

129

1297.8

... More
Vol_I_8_1_14_1 - Earth work excavation for Foundation by manual means for all Buildlings, Bridges, Retaining walls, Abutment Piers and such similar works as per drawing and technical Specifications, including setting out, pro- viding shoring and strutting,barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usageand other appurtenances required to complete the work. In all kinds of soils Depth upto 1.5 m For Sump Tank

28.31

105

2974.2486

... More
Vol_I_15_2_1_2 - Providing and laying in position plain cement concrete Mix 1 4 8 M5 Using 40 mm and down size graded crushed coarse aggregates for levelling course for all works in foundation. The graniteand trapand basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. For Sump Tank

2.57

5833

14993.1744

... More
Vol_II_9_5_3 - Providing Coursed rubble masonry second sort with hard stone in foundation and plinth with Cement mortar 1 6 1 cement 6 coarse sand For Sump Tank

15.06

6391

96250.719

... More
Vol_1_16_2_4_1 - Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The graniteand trapand basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Mix 1 2 4 M15 Using 20 mm nominal size graded crushed coarse aggregates For Sump Tank

0.3

6794

2038.2

... More
Vol_I_17_2_5_2 - Providing and laying in position Reinforced cement concrete M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates, for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The graniteand trapand basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. for Staircase, Lintels and Beams For Sump Tank

0.9

7259

6533.766

... More
Vol_II_41_8_3_2_8_12 - Providing 20 mm cement plaster of mix 1 6 1 cement 6 fine sand to brickand stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin-Charge. For Sump Tank

14.7

408

6010.977

... More
Vol_II_41_8_10 - Providing 6 mm cement plaster with cement mortar 1 3 1 cement 3 fine sand on concrete surface and ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. For Sump Tank

6.96

217

1512.6168

... More
Vol_I1_18_2_11a - Supplying, fitting and placing TMT FE 550 and 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapingand welding joints, tying with binding wire and soft annealed steel wire and other ancilary operations complete as per drawing and technical specifications. a Buildings. For Sump Tank

0.1

92140

9214.071

... More
Vol-I 8 1_14_1 - Earth work excavation for Foundation by manual means for all Buildlings, Bridges, Retaining walls, Abutment Piers and such similar works as per drawing and technical Specifications, including setting out, pro- viding shoring and strutting,barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usageand other appurtenances required to complete the work. In all kinds of soils Depth upto 1.5 m for Septic tank

11.89

105

1249.1634

... More
Vol_I_7_1_9 - Supplying and filling in plinth with sand under floors, foundation of Bridges including watering, ramming, consolidating and dressing complete. for Septic tank

5.66

2242

12691.4746

... More
vol_I_71_11 - Providing Coursed rubble masonry second sort with hard stone in foundation and plinth with Cement mortar 1 6 1 cement 6 coarse sand for Septic tank

6.93

5423

37587.4884

... More
Vol_I_8_1_14_1 - Earth work excavation for Foundation by manual means for all Buildlings, Bridges, Retaining walls, Abutment Piers and such similar works as per drawing and technical Specifications, including setting out, pro- viding shoring and strutting,barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usageand other appurtenances required to complete the work. In all kinds of soils Depth upto 1.5 m

20.36

105

2139.0216

... More
Vol_I_7_1_9 - KSRB 2.3 Filling available excavated earth excluding rock in sides of foundations upto plinth in layers not exceeding 20 cms. in depth, compacting each deposited layer by ramming after watering with lead upto 50 m. and lift upto 1.5 m. including cost of all labour complete as per specifications

9.79

210

2057.0748

... More
Vol_1_16_2_4_1 - Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The graniteand trapand basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Mix 1 2 4 M15 Using 20 mm nominal size graded crushed coarse aggregates

1.7

8885

15105.52

... More
Vol_I_17_2_5_1 - Providing and laying in position Reinforced cement concrete M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates, for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The graniteand trapand basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. for roof slab

1.7

8533

14506.678

... More
Vol_I_18_2_11a - Supplying, fitting and placing TMT FE 550 and 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapingand welding joints, tying with binding wire and soft annealed steel wire and other ancilary operations complete as per drawing and technical specification a Buildings

0.14

92140

12899.6994

... More
page_23_Item_No_5_5 - Providing Coursed rubble masonry second sort with hard stone in foundation and plinth with Cement mortar 1 6 1 cement 6 coarse sand

25.96

6391

165914.254

... More
SR_18_19_11415_19_15_23 - Providing 20mm thick cement plaster in single coat with cement mortar 1 4, to stone masonry and concrete surface including rounding off corners wherever required smooth rendering, Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. Extra for providing and mixing waterproofing compound in cement plaster work at one Kg per bag or in the proportion recommended by the manufactures, for cement mortar 1 3, 12mm thick cost of materials complete as per specifications.

62.84

278

17475.804

... More
pg_XXVIIIsl_No_781code 0331 - Providing and fixing SFRC cover from sump rectangular in shape of size 600mm x 600mm including the frame etc compelete as per manfucaturer's recommendation of reputed make such as southern concrete industries or equivalent

2

785

1571.18

... More
pg_73 item_no_11_46 - Providing and fixing CI foot rests and fixing in manhole with M10 cement concrete block of 20 x 20 x 10 cms using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications

4

243

972.32

... More
Vol_V_140_12_4 - Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE 1 dditional rate on item 1 and 2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M for fixing Casing pipes only a Above 20 M and upto 30 M - 15, b Above 30 M - 30 Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level. 2 A sum of Rs. 100and - is to be deducted for Dry Borewell towards yield test. etc. complete

1

5562

5562.9

... More
Vol_V_139_12_2_1 - Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG and above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc. for Above 300m of drilling add 10 for every 50m depth i Up to 0.00 to 50.00 mtrs

50

324

16222.5

... More
Vol_V_139_12_2_2 - Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG and above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc. for Above 300m of drilling add 10 for every 50m depth ii Up to 50.00 to 100.00 mtrs

50

406

20317.5

... More
Vol_V_139_12_2_3 - Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG and above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc. for Above 300m of drilling add 10 for every 50m depth iii Up to 100.00 to 150.00 mtrs

50

432

21630

... More
Vol_V_143_12_32 - Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kgand m.prices include Collar-Medium duty.

19

2029

38563.35

... More
Vol_II_112_ - Providing and fixing in trenches Galvanisedand mild steel tools medium grade 50mm dia nominal doorwith all fittings earth work in trenches to be measured and paid for seperately including cost of all materials. Labour charges.HOM of equipments and testing complete as per specifications ,

114

656

74812.5

... More
Vol_II_116_13_6_4_1 - Providing and fixing Gun metal wheel valve confirming to IS specification of approved quality and make as per directions with all lead and lift. i Gun metal wheel valve 50 mm

2

1140

2280.6

... More
Vol_II_491 - Providing and Fixing MS cap. complete as per specifications ,

1

1140

1140.3

... More
Vol_V_143_12_33 - Providing and Fixing MS collar complete as per specifications ,

20.5

157

3228.75

... More
NSR9 - Work at PI rooms Supply of High back chairs with head rest cushion at seat and perfo at back with chromebase with gas lift amounted on caster with synchro mechanism with adjustable handles.

1

9800

9800

... More
NSR10 - Supply of Manager table with a size of 1800Lx900dx 750h with 25mm thk. Table top with 25mm thk. Leg with 18mm thk. Modestry panel with side storage unit with a size of 900L x 450 x 750 with draw at top and shetter at bottom whole unit mounted on levellers Pl Room.

1

29800

29800

... More
NSR11 - Work at SI rooms details Supply of Medium back chair with cussion at seat and pe back with nylon base with gaslift mounted on casters with sy mechanism with adjustable handles

2

7500

15000

... More
NSR12 - Supply of Working table with a size of 1500Lx900Wx 7500h with 25mm thk. Table top with 18mm thk. Below table top leg and apron mounted on levellers at St Room-Single Pedestal Storage

2

24000

48000

... More
NSR13 - Work at SHO rooms details Supply of Medium back chair with cussion at seat and pe back with nylon base with gaslift mounted on casters with sy mechanism with adjustable handles

1

7500

7500

... More
NSR14 - Supply of Working table with a size of 1500Lx900Wx 7500h with 25mm thk. Table top with 18mm thk. Below table top leg and apron mounted on levellers at St Room-Single Pedestal Storage

1

24000

24000

... More
NSR15 - Supply of Reception table with a size of 1800Lx600dx1050M with beach colour at bottom and frosty white colour at top mounted on levellers. Note without glass at top.

1

34000

34000

... More
NSR16 - Supply of Medium back Computer Chair chair with cussion at seat e and perfo at back with powder coated metal base mounted on bushes with adjustable handles

1

6500

6500

... More
NSR17 - Supply of Tandam chair of 3seater with powder coated metal structure mounted on levellers.

1

9800

9800

... More
NSR18 - Supply of computer table with a size of 1200Lx600dx 750h with 25mm thk Table top and 18mm thk. Below table top leg and dapron with powder coated metal keyboard trey with CPL Trooly and pedestal unit with a size of 640hx 400Wx450d wooden

1

8500

8500

... More
NSR19 - Supply of Medium back Computer Chair chair with cussion at seat e and perfo at back with powder coated metal base mounted on bushes with adjustable handles

1

6500

6500

... More
Vol-6Part-IIIPage-11_2_1 - Concealed Conduit System Supplying heavy gauge PVC conduit pipe ...... mm dia. mm thick confirming to IS 2509 with suitable size bends, metaland PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19-20 mm dia 2 mm thick

565

66

37290

... More
Vol-6Part-IIIPage-11_2_2 - Concealed Conduit System Supplying heavy gauge PVC conduit pipe ...... mm dia. mm thick confirming to IS 2509 with suitable size bends, metaland PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thick

510

78

39780

... More
Vol-6Part-IIIPage-21_13 - Supplying And Fixing Metal Fan Box with Round Hook.

29

117

3393

... More
Vol-6Part-IIIPage-11_3_1 - Supplying heavy gauge PVC Conduit Pipe .... dia mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19and 20 mm dia 2 mm thick

380

68

25840

... More
Vol-6Part-IIIPage-11_3_2 - Supplying heavy gauge PVC Conduit Pipe .... dia mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25 mm dia 2 mm thick

260

79

20540

... More
Vol-6Part-IIIPage-175_19_11 - Supplying and fixing regular MCB distribution boards on walland ood board and flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phaseand 3 phaseand single door with powder coated painting Made out of 14 SWG MS enclosure. Double Door 4 Way TP and N

3

4038

12114

... More
Vol-6Part-IIIPage-73_4_1 - Supplying and flush mounting powder coated and galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brickand Stoneand C.C wall 1-2 Way

52

138

7176

... More
Vol-6Part-IIIPage-73_4_3 - Supplying and flush mounting powder coated and galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brickand Stoneand C.C wall. Make - Group "A" materials and as per the directions of Engineer in charge of the work.4-5 Way

6

177

1062

... More
Vol-6Part-IIIPage-73_4_4 - Supplying and flush mounting powder coated and galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brickand Stoneand C.C wall 6 Way

48

220

10560

... More
Vol-6Part-IIIPage-73_4_5 - Supplying and flush mounting powder coated and galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brickand Stoneand C.C wall 8 Way

22

261

5742

... More
Vol-6Part-IIIPage-73_4_5 - Supplying and flush mounting powder coated and galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brickand Stoneand C.C wall 10-12 Way

14

319

4466

... More
Vol-6Part-IIIPage-42_2_1 - Supplying and wiring adopting loop system in existing PVC Conduitand casing capping casing capping using 2x1.5Sqmm Phase and Neutral and 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire confirming to IS-694 and latest amendments without control switch shall be fixed on the existing plastic sheetand gang box, the other end of the wires shall be terminated with sufficient loose length in a woodand PVC round block.complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box

40

269

10760

... More
Vol-6Part-IIIPage-42_2_2 - Supplying and wiring adopting loop system in existing PVC Conduitand casing capping casing capping using 2x1.5Sqmm Phase and Neutral and 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire confirming to IS-694 and latest amendments without control switch shall be fixed on the existing plastic sheetand gang box, the other end of the wires shall be terminated with sufficient loose length in a woodand PVC round block.complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box

45

379

17055

... More
Vol-6Part-IIIPage-42_2_3 - Supplying and wiring adopting loop system in existing PVC Conduitand casing capping casing capping using 2x1.5Sqmm Phase and Neutral and 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire confirming to IS-694 and latest amendments without control switch shall be fixed on the existing plastic sheetand gang box, the other end of the wires shall be terminated with sufficient loose length in a woodand PVC round block.complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box

38

555

21090

... More
Vol-6Part-IIIPage-42_3_2 - Wiring for lightingand power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694 2010 1.5 mm2

980

26

25480

... More
Vol-6Part-IIIPage-42_3_3 - Wiring for lightingand power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694 2010 2.5 mm2

2800

42

117600

... More
Vol-6Part-IIIPage-42_3_4 - Wiring for lightingand power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694 2010 4 mm2

660

63

41580

... More
Vol-6Part-IIIPage-42_3_5 - Wiring for lightingand power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694 2010 6 mm2

380

92

34960

... More
Vol-6Part-IIIPage-73_5_1 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metaland PVC box. 1 to 2 Module

52

137

7124

... More
Vol-6Part-IIIPage-73_5_3 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metaland PVC box.4 Module

6

175

1050

... More
Vol-6Part-IIIPage-73_5_4 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metaland PVC box. 6 Module

48

234

11232

... More
Vol-6Part-IIIPage-73_5_5 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metaland PVC box. 8 Module

22

284

6248

... More
Vol-6Part-IIIPage-73_5_6 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metaland PVC box. 10-12 Module

14

344

4816

... More
Vol-6Part-IIIPage-83_6_1 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch

230

102

23460

... More
Vol-6Part-IIIPage-83_6_2 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Two Way Switch

8

166

1328

... More
Vol-6Part-IIIPage-83_6_3 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Three Way socket

101

171

17271

... More
Vol-6Part-IIIPage-83_6_4 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module

29

357

10353

... More
Vol-6Part-IIIPage-83_6_7 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16A One Way Switch

12

180

2160

... More
Vol-6Part-IIIPage-83_6_10 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6and 16A Universal Socket

12

236

2832

... More
Vol-6Part-IIIPage-93_14_7 - Supplying And fixingand replacing of 6and 16and 32A electrical accessories on existing switch board. 6A Batten Holder

74

63

4662

... More
Vol-6Part-IIIPage-296_1 - Supplying exhaust fan of 1440 RPM of 300 mm 12" size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.

11

1492

16412

... More
Vol-6Part-IIIPage-296_3_1 - Supplying capacitor type ceiling fan complete with down rod blades,shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep 1200 mm Regular model

29

2984

86536

... More
Vol-6Part-IIIPage-296_5_1 - Supplying wall mounting fan suitable to operate at single- phase 230v AC. supply. 300 mm Sweep

1

2492

2492

... More
Vol-6Part-IIIPage-4311_5_3 - Supply of roundand square recessand surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector and has swivelling unit of aluminium die cast eye ball and LED Lamp position retained by circular wire spring, with Life of 25000 burning hours and 70 lumen maintenance with CRI 80. Power Input 220-240V 50and 60Hz and Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical conditionLED square or round down light 15 -18W

4

1324

5296

... More
Vol-6Part-IIIPage-4211_3_2 - Supplying of .....feet -PVC Batten with integrated LED tube 20and 22 W with high quality diffuser with Life of 25000 burning hours and 70 lumen maintenance with CRI 80. Power Input 220- 240V 50and 60Hz and Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.-LED light fitting 1 x 4' - 20and 22 W

48

690

33120

... More
Vol-6Part-IIIPage-4611_11_7 - Supplying and fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322 and IEC 60598, LM 79 and LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5 of lamp Wage., short circuit and open circuit protection to be integrated in the circuit, THD less than 20, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABLand CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.18W, 6500K

26

426

11076

... More
Vol-6Part-IIIPage-5513_7_1 - Fixing all types and all capacities of fluorescent and false ceiling and spot light and CFL and LED fittings indoor on the walland ceiling and rafters and girders using 23and 0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps.On walland ceiling and Rafter and Girders

52

122

6344

... More
Vol-6Part-IIIPage-5613_10 - Fixing a ceiling and Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 and 0.0076 inch PVC insulated twin twisted copper wire and wiring.

30

171

5130

... More
Vol-6Part-IIIPage-5613_12 - Extra length of GI pipe of class B 19 mm dia for down rod.

16

197

3152

... More
Vol-6Part-IIIPage-5613_14 - Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23and 0.0076 inch PVC insulated twin core wire.

11

492

5412

... More
Vol-6Part-IIIPage-4712_2_1 - Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell

2

246

492

... More
Vol-6Part-IIIPage-165_18_4 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONand OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898-6-32 A DP

20

739

14780

... More
CSRpage-24721_1_1Vol-5 - Water purification plants Providing, Installation and Commissioning of automatic Water purification plant RO+UF with all accessories piping, product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. Ref- detailed specification enclosed seperatly. Note - 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BSI and NFS standards,with BSI and NFS mark . 3. Tenders to be invited for procurement. 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note Refer the ANNEXURE F for Detailed Specification of Each components-For 25 LPH Cabin Type

1

25000

25000

... More
Vol-6Part-IIIPage-83_6_11 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TVand Telephone Socket

3

156

468

... More
Vol-6Part-IIIPage-83_06_12 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. RJ45and I.O Outlet Cat-6

22

337

7414

... More
Vol-6Part-IIIPage-358_1 - Supplying and drawing UTP-CAT 6E LAN cable.

970

38

36860

... More
Vol-6Part-IIIPage-358_2_2 - Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable.-2Pair

120

21

2520

... More
Vol-6Part-IIIPage-358_3 - Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6.

60

44

2640

... More
Vol-6Part-IIIPage-358_4_4 - Supplying and Fixing of switch mounting rack with power manager and Cable manager.-12U with 450mm depth

1

8835

8835

... More
Vol-6Part-IIIPage-358_9_2 - Supplying fixing of Network Switches-24 Port Gigabyte manageable

1

41450

41450

... More
Vol-6Part-IIIPage-358_10_1 - Supplying and fixing of Iand O socket with back box-Single Iand O

26

490

12740

... More
Vol-6Part-IIIPage- 368_11_3 - Supplying and Fixing of ... Mtrs Cat 6 Patch Cable. 3mtr

26

331

8606

... More
Vol-6Part-IIIPage- 368_12_2 - Supplying and Fixing of Patch panel for LAN cabling. 24 Port 101100 patch panel

1

4100

4100

... More
Vol-6Part-IIIPage-368_13_1 - Supplying and fixing of MDF krone junction box with KRONE Module and Telephone cable termination.-10 Pair

1

345

345

... More
Vol-6Part-IIIPage-145_12_1 - Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. SMEnclosure Sheet Metal Execution 63 A

1

6881

6881

... More
Vol-6Part-IIIPage-165_15_9 - Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing woodand panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per ISand IEC 60947-2 . Icu=100 lcs. In 4P MCCB, all Poles should have protection for Short-Cicrcuitand Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open. Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.100 A 25 kA

1

8487

8487

... More
Vol-6Part-IIIPage-165_18_7 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONand OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898-6-32 A TPN

8

1717

13736

... More
Vol-6Part-IIIPage-175_21 - Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delayand autoand manual reset facility suitable to mount on DIN railand flush mounting on panel board.

1

9255

9255

... More
Vol-6Part-IIIPage-185_29 - Supplying, fixing and wiring 3 Phase Digital A mmeter and Voltmeter

1

1425

1425

... More
Vol-6Part-IIIPage-185_34 - Supplying, fixing and wiring 50and 5 to 400and 5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound.

3

562

1686

... More
Vol-6Part-IIIPage-185_38 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230and 440VAC. 50 Hz 12and 24V D.C.

3

515

1545

... More
Vol-6Part-IIIPage-195_40_1 - Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolicand FRPand DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete-100 A 4 x 30 x 6 mm Aluminium Strips

0.8

2465

1972

... More
Vol-6Part-IIIPage-195_41_1 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint-40 x 40 x 6 mm

8

305

2440

... More
Vol-6Part-IIIPage-195_42_2 - Fabricating supplying and mounting MS box made out SWG suitable for floor and wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7 tanks treatment with powder coated paint and finally finished with approved colour etc., complete 16 SWG

64000

-

27520

... More
Vol-6Part-IIIPage-21_9_2 - Supplying PVC flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 25 mm

18

22

396

... More
Vol-6Part-IIIPage-5312_58_2 - GI strips for grounding connections, using necessary fixing materials as required.25 x 3 mm Copper strip

20

82

1640

... More
Vol-6Part-IIIPage-5312_56 - Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm allround the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia

4

3510

14040

... More
ESR32_09Vol-6 - Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 Part-1 or IS-7098 Part-1, Armouring strip thickness in average +5 and resistivity 14 Ohmsand Kms Max as per IS-3975. 35 Sqmm, 3.5 Core, 14 GI Strips - 4 x 0.8 mm

0.16

154062

24649.92

... More
ESR21_06Vol-6 - Laying of LT cable in Existing Trenchand GI pipeand Stone Wareand RCC Hume pipe using Woodenand Aluminum Rollers as directed by the departmental staff. 35 to 95 Sqmm

0.16

31139

4982.24

... More
CSRPage-61_6_1Vol-1 - Earth work excavation for pipelinesand cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth excluding rock in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usageand other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m

60

484

29040

... More
ESR63_04Vol-6 - Supplying and fixing of heavy duty Brass Cable Gland. 45 mm dia

4

197

788

... More
Vol-6Part-IIIPage-4411_7_1 - Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonateand clear glass material, delivering superior light output. Rated life Burning Hrs 50000 hr Lumen Maintenance of 70, CCT 5500K, IP 66 optical and electrical compartment and impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltageand Overload, short circuitand miss-wiring protection. Compatible for pole mounting with outer dia of 40 mm to 50 mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50and 60Hz application. Compliance to IS 10322and IEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB LED Efficiency 130 lmand w, nominal CRI75. Luminaire manufacturer should have in- house facility accredited by NABLand CPRI and any Government certified agency and Design and Development facility certified by ISO 9001 2008. Housing with supplier word mark and name shall be Engraved and Embossing on the die cast housingand Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and Creeand Nichiaand Lumiledsand Osram make LED Source. LED Post Top Lantern with 25 W for gate

2

6922

13844

... More
Vol-6Part-IIIPage-4511_8_3 - Supply of 70 watts LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr Lumen Maintenance of 70, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment and impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltageand Overload, short circuitand miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50and 60Hz application. Compliance to IS 10322and IEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency 1301mand w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABLand CPRI and any Government certified agency and Design and Development facility certified by ISO 9001 2008. Housing with supplier word mark and name shall be Engraved and Embossing on the die cast housingand Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and Creeand Nichiaand Lumiledsand Osram make LED Source.-LED Streetlight 70W

5

5992

29960

... More
Vol-6Part-IIIPage-5513_1_1 - Supplying and Fixing of mm dia class A GI pipe bracket upto 2ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole and wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires.Using 25mm dia G.I.Pipe

5

978

4890

... More
CSRpage-15713_40_1Vol-5 - Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments.2 HP, Size 65x50 Head 13M, Discharge 462 LPM

1

15610

15610

... More
CSRpage-15213_8_7Vol-5 - Providing, Single Phase Submersible Pump Sets of 100mm dia 4 inch suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc. complete. 2.00 HPand 1.5KW 18 STG

1

19698

19698

... More
CSRpage-15613_32Vol-5 - Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work.

1

6500

6500

... More
CSRPage-15413_22_2Vol-5 - Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core sheathed of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments1x3x2.5 Sqm

170

85

14450

... More
CSRPage-15513_23_1Vol-5 - Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING 1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump 1 No. MCB 1 No. DOL of Sand D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current and dry run protection suitable for the pump described above 1 no Indoor type NOTE 1 DOL- Direct Online Starter Upto 3 HP pumps

2

6500

13000

... More
CSRPage-15513_27_1Vol-5 - Supply and delivery of galvanized mild steel tubes of 6mtr standard length heavy duty C Class as per IS 1239 Part-I 1990 with latest amendments with ISI Mark one end fitted with Heavy Duty collar and other end fitted with protective cover50 mm

20

3050

61000

... More
CSRPage-15413_24_1Vol-5 - Supply and delivery at site of brand new best make gate valve as per IS 778and 1984 with ISI Mark and as per its latest amendments 50 mm dia.

2

1250

2500

... More
CSRPage-15413_25_1Vol-5 - Supply and delivery at site of brand new best makeNon -return valve as per IS 778and 1984 with ISI Mark and as per its latest amendments 50 mm dia.

2

1250

2500



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.