Karnataka State Police Housing And Infrastructure Development Corporation Limited Tender

... More
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Karnataka State Police Housing And Infrastructure Development Corporation Limited - KSPHCL Tender

Works
Building Construction
Opening Date1 Feb 2025
Closing Soon4 Mar 2025
Tender Amount₹ 13,26,74,098.13 
Notes
Download

Costs

Summary

Construction Of Pre-metric/post-metric Hostel Buildings For Boys & Girls At Khustagi, Koppal,

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Page No. 8 vol-1 1.12 - Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth - For Building, Soak & RWH

258.8

99

25815.3

... More
Page No.8 vol-1 1.14.1 - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3m - For Building, Sump, Septic, Soak, RWH & Washing Platform

5494.48

107

588458.808

... More
Page No.15 vol-1 2.1.2 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately). Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates For Building, Sump, Septic, Soak, RWH & Washing Platform

448.57

5947

2667735.504

... More
Page No.5 vol-2 4.1 - Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. Lindane 20% E.C. @ 3.19 l m2 including cost of chemical, diluting in water to one percent concentration, labour, usagecharges of machinery, complete as per specifications.

2402

123

297607.8

... More
Page No.18 vol-1 2.10c - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade - For footings

740.85

7052

5224733.4975

... More
Page No.16 vol-1 2.4.3 - Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For columns - Up to Plinth

17.21

11309

194640.9696

... More
Page No.16 vol-1 2.5.2 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For columns - Above Plinth

41.14

12214

502515.2264

... More
Page No.16 vol-1 2.5.2 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For columns - First Floor

33.78

12336

416740.482

... More
Page No.16 vol-1 2.5.2 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For columns - Second Floor

27.99

12459

348728.8095

... More
Page No.16 vol-1 2.5.2 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For columns-Third Floor

25.33

12581

318681.796

... More
Page No.16 vol-1 2.5.2 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For columns-Terrace Floor

7.97

12703

101245.6995

... More
Page No.16 vol-1 2.3.2 - Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications - For grade & plinth beam.

100.77

10206

1028458.62

... More
Page No.16 vol-1 2.5.1 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Lintel - Ground Floor

26.11

11138

290823.624

... More
Page No.16 vol-1 2.5.1 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Lintel - First Floor

33.2

11249

373492.696

... More
Page No.16 vol-1 2.5.1 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Lintel - Second Floor

24.9

11361

282893.133

... More
Page No.16 vol-1 2.5.1 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Lintel - Third Floor

24.9

11472

285666.495

... More
Page No.18 vol-1 2.10c - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade - For Roof beam - Ground Floor

67.89

10447

709309.2888

... More
Page No.18 vol-1 2.10c - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade - For Roof beam - First Floor

64.05

10552

675881.22

... More
Page No.18 vol-1 2.10c - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade - For Roof beam - Second Floor

49.58

10656

528368.1104

... More
Page No.18 vol-1 2.10c - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade - For Roof beam - Third Floor

48.03

10761

516868.1208

... More
Page No.18 vol-1 2.10c - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade - For Roof beam - Terrace Floor

4.64

10865

50417.4976

... More
Page No.18 vol-1 2.10c - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade - For Roof slab - Ground Floor

220.19

9794

2156745.6367

... More
Page No.18 vol-1 2.10c - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade - For Roof slab - First Floor

183.44

9892

1814748.0728

... More
Page No.18 vol-1 2.10c - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade - For Roof slab - Second Floor

142.7

9990

1425690.014

... More
Page No.18 vol-1 2.10c - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade - For Roof slab - Third Floor

137.58

10088

1388012.9766

... More
Page No.18 vol-1 2.10c - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade - For Roof slab - Terrace Floor

15.35

10186

156366.152

... More
Page No.9 Vol-2 5.2 - Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) - For Building & Washing Platform

108.03

6948

750689.667

... More
Page No.7 vol-1 1.9 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m - For Building, Sump, Septic, Soak & RWH

1692.28

279

472653.804

... More
Page No.7 vol-1 1.8 - Construction of Embankment by excavating the available approved Gravel Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work - For Building & Washing Platform

3696.02

497

1839509.154

... More
Page No.16 vol-1 2.5.1 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Chejjas -Ground Floor

14.69

10094

148283.5042

... More
Page No.16 vol-1 2.5.1 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Chejjas - First Floor

13.82

10195

140896.5584

... More
Page No.16 vol-1 2.5.1 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Chejjas -Second Floor

10.37

10296

106770.1422

... More
Page No.16 vol-1 2.5.1 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Chejjas -Third Floor

10.37

10397

107816.89

... More
SR2018-19 Shivamogga circle Page -15 Item NO. 4.21 - KSRB 4-2.12 : Extra for providing throating or drip moulding to R.C.C chajja with plastering (labour charges only) as per specifications and directions of the Engineer - in - charge of the work. Specification - Ground Floor

614.4

36

22708.224

... More
SR2018-19 Shivamogga circle Page -15 Item NO. 4.21 - KSRB 4-2.12 : Extra for providing throating or drip moulding to R.C.C chajja with plastering (labour charges only) as per specifications and directions of the Engineer - in - charge of the work. Specification - First Floor

614.4

37

22935.552

... More
SR2018-19 Shivamogga circle Page -15 Item NO. 4.21 - KSRB 4-2.12 : Extra for providing throating or drip moulding to R.C.C chajja with plastering (labour charges only) as per specifications and directions of the Engineer - in - charge of the work. Specification - Second Floor

460.8

37

17372.16

... More
SR2018-19 Shivamogga circle Page -15 Item NO. 4.21 - KSRB 4-2.12 : Extra for providing throating or drip moulding to R.C.C chajja with plastering (labour charges only) as per specifications and directions of the Engineer - in - charge of the work. Specification - Third Floor

460.8

38

17542.656

... More
Page No.13 vol-2 6.7 - Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work - Ground Floor

271.56

8621

2341268.118

... More
Page No.14 vol-2 6.8 - Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work - First Floor

253.14

8707

2204284.8978

... More
Page No.14 vol-2 6.8 - Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work - Second Floor

220.16

8793

1936082.6368

... More
Page No.14 vol-2 6.8 - Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work - Third Floor

189.85

8880

1685905.97

... More
Page No.14 vol-2 6.8 - Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work - Terrace Floor

90.93

8966

815315.6613

... More
Page No.14 vol-2 6.15 - Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work - Ground Floor - For Building & Wardrobe

729.72

1084

791490.798

... More
Page No.14 vol-2 6.15 - Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work - First Floor

395.99

1095

433807.045

... More
Page No.14 vol-2 6.15 - Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work - Second Floor

294.08

1106

325352.4672

... More
Page No.14 vol-2 6.15 - Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work - Third Floor

294.08

1117

328543.2352

... More
Page No.15 vol-1 2.5.1 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - Cill Concrete - Ground Floor

13.9

6961

96764.85

... More
Page No.15 vol-1 2.5.1 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - Cill Concrete - First Floor

10.79

7031

75865.7848

... More
Page No.15 vol-1 2.5.1 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - Cill Concrete - Second Floor

9.6

7100

68167.008

... More
Page No.15 vol-1 2.5.1 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - Cill Concrete - Third Floor

8.09

7170

58008.1315

... More
Page No.15 vol-1 2.5.1 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - Cill Concrete - Terrace Floor

4.5

7239

32579.82

... More
Page No.41 vol-2 8.3.1 - Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.

328

371

121917.6

... More
Page No.15 vol-1 2.1.6 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates

87.56

6555

573968.934

... More
Page No. Vol-259 9.5 - Extra for making chequers of approved pattern on 1:2:4 cement concrete floors, steps, landing pavements etc.,

1536.53

57

88734.6075

... More
Page No.86 vol-2 11.34B - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings wooden frames with rawl plugs screws etc - Ground Floor

8981.34

192

1725764.481

... More
Page No.85 vol-2 11.34B - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings wooden frames with rawl plugs screws etc - First Floor

6875.83

194

1334392.3281

... More
Page No.85 vol-2 11.34B - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings wooden frames with rawl plugs screws etc - Second Floor

5990.36

195

1174050.6564

... More
Page No.85 vol-2 11.34B - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings wooden frames with rawl plugs screws etc - Third Floor

5156.87

197

1020596.1417

... More
Page No.85 vol-2 11.34B - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings wooden frames with rawl plugs screws etc - Terrace Floor

2500.47

199

499693.9248

... More
Page No.18 vol-1 2.11(a) - Supplying, fitting and placing TMT FE 550 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping welding joints, tying with binding wire soft annealed steel wire and other ancilary operations complete as per drawing and technical specification - Ground Floor - For Building, Sump, Septic, Soak & RWH

121.99

93929

11458502.4015

... More
Page No.18 vol-1 2.11(a) - Supplying, fitting and placing TMT FE 550 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping welding joints, tying with binding wire soft annealed steel wire and other ancilary operations complete as per drawing and technical specification - First Floor

35.53

94869

3370700.8995

... More
Page No.18 vol-1 2.11(a) - Supplying, fitting and placing TMT FE 550 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping welding joints, tying with binding wire soft annealed steel wire and other ancilary operations complete as per drawing and technical specification - Second Floor

27.8

95808

2663474.91

... More
Page No.18 vol-1 2.11(a) - Supplying, fitting and placing TMT FE 550 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping welding joints, tying with binding wire soft annealed steel wire and other ancilary operations complete as per drawing and technical specification - Third Floor

26.64

96747

2577360.06

... More
Page No.18 vol-1 2.11(a) - Supplying, fitting and placing TMT FE 550 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping welding joints, tying with binding wire soft annealed steel wire and other ancilary operations complete as per drawing and technical specification - Terrace Floor

3.47

97687

338974.0288

... More
Page No.43 vol-2 8.10 - Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge - Ground Floor - For Building, Sump & Septic

1903.15

221

421642.8825

... More
Page No.43 vol-2 8.10 - Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge - First Floor

1332.24

223

298115.3448

... More
Page No.43 vol-2 8.10 - Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge - Second Floor

1018.81

225

230230.6838

... More
Page No.43 vol-2 8.10 - Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge - Third Floor

999.18

228

228012.876

... More
Page No.43 vol-2 8.10 - Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge - Terrace Floor

58.89

230

13568.8449

... More
Page No.41 vol-2 8.4.2 - Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge - Ground Floor

2757.25

327

903275.1

... More
Page No.41 vol-2 8.4.2 - Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge - First Floor

2667.4

330

882589.312

... More
Page No.41 vol-2 8.4.2 - Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge - Second Floor

1996.4

334

667097.06

... More
Page No.41 vol-2 8.4.2 - Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge - Third Floor

1972.74

337

665661.6582

... More
Page No.41 vol-2 8.4.2 - Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge - Terrace Floor

70.99

340

24186.293

... More
Page No.42 vol-2 8.5.2 - Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners whereverrequired smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge - Ground Floor

1874.28

366

686829.906

... More
Page No.42 vol-2 8.5.2 - Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners whereverrequired smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge - First Floor

1728.99

370

639916.4889

... More
Page No.42 vol-2 8.5.2 - Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners whereverrequired smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge - Second Floor

1573.72

373

588225.0616

... More
Page No.42 vol-2 8.5.2 - Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners whereverrequired smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge - Third Floor

1296.74

377

489441.5456

... More
Page No.42 vol-2 8.5.2 - Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners whereverrequired smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge - Terrace Floor

830.94

381

316679.5434

... More
Page No.42 vol-2 8.2.1 - Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge - Ground Floor

527.81

309

163489.1475

... More
Page No.42 vol-2 8.2.1 - Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge - First Floor

764.9

312

239298.965

... More
Page No.42 vol-2 8.2.1 - Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge - Second Floor

573.67

315

181251.0365

... More
Page No.42 vol-2 8.2.1 - Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge - Third Floor

573.67

319

183023.6768

... More
Page No.44 Vol-2 8.16a - Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications.

55.1

1299

71624.49

... More
Page No.43 vol-2 8.16.3 - Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment).

11200

46

517440

... More
Page No.110 vol-2 12.89 - Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - Ground Floor

142.56

6878

980606.088

... More
Page No.110 vol-2 12.89 - Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - First Floor

138.96

6947

965402.3664

... More
Page No.110 vol-2 12.89 - Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - Second Floor

106.38

7016

746374.8456

... More
Page No.110 vol-2 12.89 - Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - Third Floor

104.22

7084

738389.3202

... More
Page No.110 vol-2 12.89 - Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - Terrace Floor

6.48

7153

46355.9112

... More
Page No.109 vol-2 12.85 - Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - Ground Floor

130.32

6004

782565.084

... More
Page No.109 vol-2 12.85 - Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - First Floor

146.88

6065

890827.2

... More
Page No.109 vol-2 12.85 - Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - Second Floor

111.24

6125

681350.562

... More
Page No.109 vol-2 12.85 - Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - Third Floor

110.16

6185

681350.616

... More
Page No.109 vol-2 12.85 - Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - Terrace Floor

3.24

6245

20234.286

... More
Page No.85 vol-2 11.28 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge - Ground Floor

2013.46

593

1194485.145

... More
Page No.85 vol-2 11.28 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge - First Floor

796.74

599

477390.6732

... More
Page No.85 vol-2 11.28 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge - Second Floor

597.55

605

361589.456

... More
Page No.85 vol-2 11.28 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge - Third Floor

597.55

611

365132.9275

... More
Page No.100 vol-2 12.13.2 - Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications - Ground Floor

1.78

104580

186152.4

... More
Page No.100 vol-2 12.13.2 - Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications - First Floor

1.22

105625

128863.476

... More
Page No.100 vol-2 12.13.2 - Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications - Second Floor

0.96

106671

102404.736

... More
Page No.100 vol-2 12.13.2 - Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications - Third Floor

0.91

107717

98022.834

... More
Page No.100 vol-2 12.13.2 - Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications - Terrace Floor

0.16

108763

17402.112

... More
Page No.100 vol-2 12.17 - Providing and fixing in position fully panelled Honne wood shutters for doors with , stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures)

21.5

7439

159943.875

... More
Page No.105 vol-2 12.57.1 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification -30mm thick both side teak - Ground floor.

63.21

4245

268335.9315

... More
Page No.105 vol-2 12.57.1 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification -30mm thick both side teak - First Floor

63.21

4287

271019.196

... More
Page No.105 vol-2 12.57.1 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification -30mm thick both side teak - Second Floor

49.67

4330

215073.5835

... More
Page No.105 vol-2 12.57.1 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification -30mm thick both side teak - Third Floor

47.41

4372

207300.225

... More
Page No.105 vol-2 12.57.1 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification -30mm thick both side teak - Terrace Floor

6.77

4414

29889.2792

... More
Page No.105 Vol-2 12.60 - Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.

4

1104

4418.4

... More
Page No.219 Vol-2 22.15.4 - Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Aldrop 16mm dia, 300mm

130

393

51187.5

... More
Page No.105 Vol-2 12.61 - Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.

130

1039

135135

... More
Page No.105 Vol-2 12.62 - Providing and fixing chromium plated brass handles of 100 125 mm with necessary screws etc. complete

260

248

64701

... More
Page No.105 Vol-2 12.63 - Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete

260

136

35490

... More
Page No.105 Vol-2 12.64 - Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms

130

57

7507.5

... More
Page No.107 Vol-2 12.74.1 - Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm

520

107

55692

... More
Page No.112 vol-2 12.94.1 - Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder rice husk wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N mm2 , modulus of elasticity 850 N mm2 and resistance to spread of flame of Class A category with property of being termite borer proof, water moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) - 30mm thick - Ground Floor

30.24

3659

110655.72

... More
Page No.112 vol-2 12.94.1 - Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder rice husk wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N mm2 , modulus of elasticity 850 N mm2 and resistance to spread of flame of Class A category with property of being termite borer proof, water moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) - 30mm thick - First Floor

63

3695

232837.92

... More
Page No.112 vol-2 12.94.1 - Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder rice husk wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N mm2 , modulus of elasticity 850 N mm2 and resistance to spread of flame of Class A category with property of being termite borer proof, water moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) - 30mm thick - Second Floor

47.25

3732

176357.79

... More
Page No.112 vol-2 12.94.1 - Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder rice husk wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N mm2 , modulus of elasticity 850 N mm2 and resistance to spread of flame of Class A category with property of being termite borer proof, water moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) - 30mm thick - Third Floor

47.25

3769

178086.6675

... More
Page No.111 vol-2 12.93.1 - Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door window Clerestory windows & other Frames Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder rice husk wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N mm2 , modulus of elasticity 900 N mm2 and resistance to spread of flame of Class A category with property of being termite borer proof, water moisture proof and fire retardant and fixed in position with M.S hold fast lugs SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) - size 62 x 100mm - Ground Floor

96.8

737

71351.28

... More
Page No.111 vol-2 12.93.1 - Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door window Clerestory windows & other Frames Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder rice husk wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N mm2 , modulus of elasticity 900 N mm2 and resistance to spread of flame of Class A category with property of being termite borer proof, water moisture proof and fire retardant and fixed in position with M.S hold fast lugs SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) - size 62 x 100mm - First Floor

232

744

172717.04

... More
Page No.111 vol-2 12.93.1 - Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door window Clerestory windows & other Frames Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder rice husk wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N mm2 , modulus of elasticity 900 N mm2 and resistance to spread of flame of Class A category with property of being termite borer proof, water moisture proof and fire retardant and fixed in position with M.S hold fast lugs SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) - size 62 x 100mm - Second Floor

174

751

130820.16

... More
Page No.111 vol-2 12.93.1 - Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door window Clerestory windows & other Frames Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder rice husk wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N mm2 , modulus of elasticity 900 N mm2 and resistance to spread of flame of Class A category with property of being termite borer proof, water moisture proof and fire retardant and fixed in position with M.S hold fast lugs SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) - size 62 x 100mm - Third Floor

174

759

132102.54

... More
Page No.104 vol-2 12.51 - Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications - Ground Floor

36

1066

38404.8

... More
Page No.104 vol-2 12.51 - Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications - First Floor

28

1077

30169.16

... More
Page No.104 vol-2 12.51 - Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications - Second Floor

22

1088

23939.08

... More
Page No.104 vol-2 12.51 - Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications - Third Floor

21

1098

23074.8

... More
Page No.104 vol-2 12.51 - Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications - Terrace Floor

3

1109

3328.41

... More
Page No.23 vol-2 7.18 - Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications - First Floor

20.2

2139

43208.406

... More
Page No.23 vol-2 7.18 - Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications - Second Floor

15.15

2160

32727.1815

... More
Page No.23 vol-2 7.18 - Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications - Third Floor

15.15

2160

32727.1815

... More
Page No.63 vol-2 9.24 - Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent - Ground Floor

200.99

2994

601884.654

... More
Page No.63 vol-2 9.24 - Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent - First Floor

65.7

3024

198712.935

... More
Page No.63 vol-2 9.24 - Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent - Second Floor

49.28

3054

150525.2672

... More
Page No.63 vol-2 9.24 - Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent - Third Floor

49.28

3084

152001.2032

... More
Page No.65 vol-2 9.39 - Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications - Ground Floor

43.41

1521

66046.1445

... More
Page No.65 vol-2 9.39 - Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications - First Floor

30.81

1536

47344.4946

... More
Page No.65 vol-2 9.39 - Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications - Second Floor

23.11

1551

35863.9468

... More
Page No.65 vol-2 9.39 - Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications - Third Floor

23.11

1567

36215.4499

... More
Page No.63 vol-2 9.29 - Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications - Ground Floor

17.64

4521

79755.732

... More
Page No.63 vol-2 9.29 - Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications - First Floor

182.22

4566

832109.4522

... More
Page No.63 vol-2 9.29 - Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications - Second Floor

136.67

4611

630285.1391

... More
Page No.63 vol-2 9.29 - Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications - Third Floor

136.67

4656

636463.9898

... More
Page No.63 vol-2 9.23 - Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent - Ground Floor

361.38

2589

935721.234

... More
Page No.69 Vol-2 10.1.2 - Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2

30.36

4133

125503.686

... More
Page No.60 vol-2 9.12.2 - Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg m2 including grouting the joints with white cement and matching pigments etc., complete - Ground Floor

953.63

1202

1146501.6675

... More
Page No.60 vol-2 9.12.2 - Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg m2 including grouting the joints with white cement and matching pigments etc., complete - First Floor

901.14

1214

1094227.2678

... More
Page No.60 vol-2 9.12.2 - Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg m2 including grouting the joints with white cement and matching pigments etc., complete - Second Floor

675.86

1226

828807.118

... More
Page No.60 vol-2 9.12.2 - Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg m2 including grouting the joints with white cement and matching pigments etc., complete - Third Floor

675.86

1238

836930.9552

... More
Page No.65 vol-2 9.39 - Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications - Ground Floor

527.81

1521

803036.5245

... More
Page No.65 vol-2 9.39 - Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications - First Floor

764.9

1536

1175391.234

... More
Page No.65 vol-2 9.39 - Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications - Second Floor

573.67

1551

890266.9996

... More
Page No.65 vol-2 9.39 - Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications - Third Floor

573.67

1567

898992.5203

... More
Page No.60 vol-2 9.11 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg m2 including pointing the joints with white cement and matching pigments etc., complete - Ground Floor

88.2

933

82330.29

... More
Page No.60 vol-2 9.10 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg m2 including pointing the joints with white cement and matching pigments etc., complete - First Floor

271.85

942

256294.743

... More
Page No.60 vol-2 9.10 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg m2 including pointing the joints with white cement and matching pigments etc., complete - Second Floor

203.89

952

194127.7468

... More
Page No.60 vol-2 9.10 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg m2 including pointing the joints with white cement and matching pigments etc., complete - Third Floor

203.89

961

196030.0405

... More
Page No.62 vol-2 9.20.1 - Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 500x500 mm - Ground Floor

88.2

266

23522.94

... More
Page No.62 vol-2 9.20.1 - Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 500x500 mm - First Floor

271.85

269

73228.2345

... More
Page No.62 vol-2 9.20.1 - Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 500x500 mm - Second Floor

203.89

272

55464.1967

... More
Page No.62 vol-2 9.20.1 - Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 500x500 mm - Third Floor

203.89

274

56008.583

... More
Page No.50 vol-2 8.51 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge - Ground Floor

4375.11

105

459386.55

... More
Page No.50 vol-2 8.51 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge - First Floor

3999.64

106

424161.822

... More
Page No.50 vol-2 8.51 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge - Second Floor

3015.21

107

322928.991

... More
Page No.50 vol-2 8.51 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge - Third Floor

2971.92

108

321413.148

... More
Page No.50 vol-2 8.51 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge - Terrace Floor

129.88

109

14182.896

... More
Page No.48 Vol-2 8.39 - Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 g L as per specifications and asper directions of Engineer in charge - Ground Floor

3900.36

189

737168.04

... More
Page No.48 Vol-2 8.39 - Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 g L as per specifications and asper directions of Engineer in charge - First Floor

3999.64

190

763491.2796

... More
Page No.48 Vol-2 8.39 - Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 g L as per specifications and asper directions of Engineer in charge - Second Floor

3015.21

192

581272.1838

... More
Page No.48 Vol-2 8.39 - Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 g L as per specifications and asper directions of Engineer in charge - Third Floor

2971.92

194

578543.6664

... More
Page No.48 Vol-2 8.39 - Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 g L as per specifications and asper directions of Engineer in charge - Terrace Floor

129.88

196

25529.2128

... More
Page No.46 vol-2 8.31 - Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L 10 m² over and including priming coat of exterior primer applied @ 2.20 kg 10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge - Ground Floor

1923.89

186

359575.041

... More
Page No.46 vol-2 8.31 - Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L 10 m² over and including priming coat of exterior primer applied @ 2.20 kg 10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge - First Floor

1646.84

188

310873.9868

... More
Page No.46 vol-2 8.31 - Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L 10 m² over and including priming coat of exterior primer applied @ 2.20 kg 10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge - Second Floor

1498.21

190

285618.7544

... More
Page No.46 vol-2 8.31 - Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L 10 m² over and including priming coat of exterior primer applied @ 2.20 kg 10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge - Third Floor

1218.44

192

234561.8844

... More
Page No.46 vol-2 8.31 - Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L 10 m² over and including priming coat of exterior primer applied @ 2.20 kg 10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge - Terrace Floor

830.94

194

161518.1172

... More
Page No.45 vol-2 8.29 - Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L 10 m²) over and including priming coat of exterior primer applied @ 2.20kg 10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge - First Floor

82.15

300

24654.858

... More
Page No.45 vol-2 8.29 - Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L 10 m²) over and including priming coat of exterior primer applied @ 2.20kg 10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge - Second Floor

75.51

303

22886.3259

... More
Page No.45 vol-2 8.29 - Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L 10 m²) over and including priming coat of exterior primer applied @ 2.20kg 10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge - Third Floor

78.31

306

23967.5586

... More
Page No.48 vol-2 8.41 - Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.

474.75

175

83247.4125

... More
Page No.47 vol-2 8.34.3 & 8.33.3 - Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr 10 m² over an under coat of primer applied @ 0.80 ltr 10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge - Ground Floor

355.88

198

70624.386

... More
Page No.47 vol-2 8.34.3 & 8.33.3 - Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr 10 m² over an under coat of primer applied @ 0.80 ltr 10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge - First Floor

315.2

200

63175.536

... More
Page No.47 vol-2 8.34.3 & 8.33.3 - Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr 10 m² over an under coat of primer applied @ 0.80 ltr 10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge - Second Floor

257.64

202

52151.4888

... More
Page No.47 vol-2 8.34.3 & 8.33.3 - Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr 10 m² over an under coat of primer applied @ 0.80 ltr 10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge - Third Floor

236.4

204

48320.16

... More
Page No.47 vol-2 8.34.3 & 8.33.3 - Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr 10 m² over an under coat of primer applied @ 0.80 ltr 10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge - Terrace Floor

63.72

206

13151.1708

... More
Page No.47 vol-2 8.34.1 & 8.33.2 - Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr 10 m² over an under coat of primer applied @0.75 ltr 10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge - Ground Floor

7.94

200

1592.367

... More
Page No.47 vol-2 8.34.1 & 8.33.2 - Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr 10 m² over an under coat of primer applied @0.75 ltr 10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge - First Floor

8.38

202

1697.4528

... More
Page No.47 vol-2 8.34.1 & 8.33.2 - Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr 10 m² over an under coat of primer applied @0.75 ltr 10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge - Second Floor

6.52

204

1333.7312

... More
Page No.47 vol-2 8.34.1 & 8.33.2 - Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr 10 m² over an under coat of primer applied @0.75 ltr 10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge - Third Floor

6.29

206

1299.3253

... More
Page No.47 vol-2 8.34.1 & 8.33.2 - Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr 10 m² over an under coat of primer applied @0.75 ltr 10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge - Terrace Floor

0.7

208

145.999

... More
Page No.Approved Rate - Providing Patti around doors, windows, ventilators and for parapet and compound wall etc., with cement mortar 1:3 and finished as per design and specification including scaffolding etc., complete including curing, cost and conveyance of all materials, cost of labour and equipment with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,.

5000

30

150000

... More
Page No.54 Vol-2 8.80 - Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth.

11400

69

790020

... More
Page No.49 vol-2 8.49 - Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.

35000

4

147000

... More
Page No.149 Vol-2 15.1 - Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace Chajjas Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.

2802.11

857

2403790.0635

... More
Page No.63 Vol-2 9.25 - Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.

167.6

840

140784

... More
Page No.SR 2018-19 P.No.149 I.No.19.88 - KSRRB M300-9. Planting of trees by the road side (Avenue trees) in 0.60 m dia holes, 1m deep dug in the ground, mixing the soil with decayed farm yard sludge manure, planting the saplings, backfilling the trench, watering, fixing the tree guard and maintenance the plants for one year complete as per specifications.MORTH Specification No.307.

32

1050

33600

... More
Page No.6 vol-1 1.6.1 - WATER SUPPLY - Earth work excavation for pipelines cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking theselected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.

407.52

508

207101.664

... More
Page No.7 vol-1 1.10 - Refilling available earth around trenches pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications

407.52

168

68463.36

... More
Page No.122 vol-2 13.31.2 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall -20 mm nominal dia Pipes

1449.01

254

368193.441

... More
Page No.122 vol-2 13.31.3 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall -25 mm nominal dia Pipes

1120

333

373968

... More
Page No.122 vol-2 13.31.4 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall -32 mm nominal dia Pipes

590.61

420

248056.2

... More
Page No.122 vol-2 13.31.6 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall -50 mm nominal dia Pipes

323.6

820

265368.18

... More
Page No.114-5 10.2.1 - Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for:Pipes of SN 4, 75mm dia.

1129.39

227

257331.5115

... More
Page No.113 vol-5 10.1.7 - Providing PVC ringtite pipes 110mm dia conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 75mm dia., 6 kg sqcm & class 3

1340.6

431

578535.93

... More
Page No.114 vol-5 10.2.8 - Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for: PPipes of SN 8, 110mm dia.

1420

364

517377

... More
Page No.114 vol-5 10.2.10 - Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for: Pipes of SN 8, 160mm dia.

350

731

256147.5

... More
Page No.139 Vol-2 14.55a - Providing and fixing Bib cock with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class - Economy

140

1172

164199

... More
Page No.119 Vol-2 13.14 - Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 g.

158

888

140351.4

... More
Page No.141 Vol-2 14.67a - Providing and fixing Exposed set for concealed stop cock made of Stainless steel with all concealed fitting rrangements & all necessary accessories complete - Class - Economy

146

632

92286.6

... More
Page No.140 Vol-2 14.56a - Providing and fixing Bib cock Two way with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class

62

2024

125512.8

... More
Page No.145 Vol-2 14.95 a - Providing and fixing Bidet spray made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class - Economy

65

880

57261.75

... More
Page No.124 vol-2 13.46 - Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : * 100 mm inlet and 75 mm outlet * Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905

160

498

79800

... More
Page No.120 vol-2 13.22.1.2 - Providing and fixing PTMT grating of approved quality and colour. 125 mm nominal dia

160

46

7392

... More
Page No.Approved Rate - Providing 10cms dia PVC cowl with cap of approved 1 st quality and make conforming to ISI specifications and fixing in position as directed (Rate includes cost of materials fixtures including conveyance charges to the work spot) including cost and conveyance of all materials, cost of labour and equipment, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification,designs,drawings etc,. complete and directions of the Engineer in-charge of the work.

120

105

12600

... More
Page No.136 vol-2 14.31 - Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

76

1281

97356

... More
Page No.137 vol-2 14.40.2 - Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.

66

520

34372.8

... More
Page No.131 vol-2 14.3.1 - Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid

57

6275

357723.45

... More
Page No.131 vol-2 14.1 - Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests

9

5128

46153.8

... More
Page No.132 vol-2 14.7.1 - Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps.

96

3236

310665.6

... More
Page No.133 vol-2 14.8 - Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.

80

1494

119532

... More
Page No.117 vol-2 13.4.2 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end): 32 mm nominal bore

80

627

50232

... More
Page No.117 vol-2 13.4.4 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end): 50 mm nominal bore

80

897

71820

... More
Page No.123 vol-2 13.34 - Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

28000

9

264600

... More
Page No.Approved Rate Ph-2 Police Gruha-2025 - Wall bores in size stone masonry 45cm thick

56

333

18664.8

... More
Page No.123 Vol-2 13.36 - Cutting holes up to 30x30 cm in walls including making good the same: With common burnt clay F.P.S. (non modular) bricks

316

339

107171.4

... More
Page No.191 vol-5 16.10 - Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.

64

4447

284659.2

... More
Page No.191 vol-5 16.9 - Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.

48

5726

274881.6

... More
Page No.15 vol-1 2.2.3 - Sump Tank - Providing and laying in position Reinforced cement concrete for all Foundation works. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For footings - For Sump & Septic

31.28

6852

214342.4464

... More
Page No.16 vol-1 2.4.3 - Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Wall concrete - - For Sump & Septic

35.8

8981

321529.824

... More
Page No.17 vol-1 2.5.2 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For roof slab - For Sump & Septic

8.44

10777

90964.0412

... More
Page No.85 vol-5 7.3 - Providing and fixing MS inspection door of size 60 cms x 60 cms, including MS frame made of 50x50x6mm angle, shutters made of 3mm thick MS sheets, with hinges, locking arrangements at top etc. including painting with anticorrosive approved paint etc. complete including all lead and lifts etc - For Sump & Septic

8

2247

17976

... More
Page No.85 vol-5 7.1.1 - Providing and fixing MS ladder between landings, 45 cms wide using angle iron of specified sizes, 20mm MS bars at 25 cms. centre to centre, with necessary supports of same angle iron etc. as directed, including hand railing on both sides with 25mm dia. GI pipes with angle iron props at 2 mtrs. intervals and 0.5M heigh, including fixing in ground with CC 1:2:4 and two coats of anticorrosive bituminous paint etc. with all lead and lifts etc. complete with: MS angle of 65 x 65 x 8mm - For Sump & Septic

20

4595

91917

... More
Page No.48 vol-2 8.36.2 - Finishing with Epoxy paint (two coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On concrete work including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge - For Sump

110.6

180

19974.36

... More
Page No.15 vol-1 2.1.6 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates - For Sump & Septic

2.88

6555

18878.832

... More
Page No.122 Vol-2 13.33.5 - Providing and fixing 40mm dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge - For Sump

80

500

40068

... More
Page No.122 Vol-2 13.33.6 - Providing and fixing 50mm dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge - For Sump

120

757

90846

... More
Page No.113 vol-5 10.1.9 - Septic Tank - Providing PVC ringtite pipes 160mm dia conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 75mm dia., 6 kg sqcm & class 3 - For Septic

100

648

64890

... More
Page No.191 vol-5 16.9 - Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover - For Septic

8

5726

45813.6

... More
Page No.126 vol-2 13.52 - Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) With common burnt clay (non modular) bricks of class designation 3.5 - For Septic

8

11083

88670.4

... More
Page No.16 vol-1 2.5.2 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Roof slab - For Soak pit & RWH

1.76

11036

19423.4128

... More
Page No.208 vol-5 16.62.2 - Providing to work spot rolling, lowering and placing in position RCC perforated rings in the already excavated pit including loading and unloading at both the destinations with all lead and lift with appurtenances., complete. 1200 mmx1250 mm - For Soak pit & RWH

24

10021

240508.8

... More
Page No.140 Vol-5 12.4 - BOREWELL - Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100 - is to be deducted for Dry Borewell towards yield test. etc. complete.

8

5552

44419.2

... More
Page No.139 Vol-5 12.2.1 - Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: (Above 300m of drilling add 10% for every 50m depth)

400

324

129780

... More
Page No.139 Vol-5 12.2.2 - Borewell depth of 50 to 100 Mtrs

400

406

162540

... More
Page No.139 Vol-5 12.2.3 - Borewell depth of 100 to 150 Mtrs

400

432

173040

... More
Page No.139 Vol-5 12.2.4 - Borewell depth of 150 to 200 Mtrs

400

501

200760

... More
Page No.143 Vol-5 12.32 - Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg m.prices include Collar-Medium duty.

160

2029

324744

... More
Page No.143 Vol-5 12.33 - Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments.

16

157

2520

... More
Page No.143 Vol-5 12.34 - Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge.

8

172

1377.6

... More
Page No.122 Vol-2 13.33.6 - Providing and fixing 50mm dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.

400

757

302820

... More
Page No.9 Vol-2 5.4 - Washing Plat form - Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) - For Washing Platform

47.99

6708

321938.5155

... More
Page No.17 vol-2 6.34 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg m3 and minimum compressive strength of 4.00 N mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications - For Washing Platform

135.1

1159

156607.92

... More
Page No.15 vol-1 2.1.4 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately). Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates - For Washing Platform & Wardrobe

20.76

6527

135518.166

... More
Page No.59 Vol-2 9.1 - Providing and laying Cement concrete flooring 40 mm thick with 20 mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete - - For Washing Platform

196

473

92815.8

... More
Page No.42 vol-2 8.9 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement:3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge - - For Washing Platform

326.34

404

131922.945

... More
Page No.45 Vol-2 8.28 - Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg 10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge - - For Washing Platform

326.34

93

30496.473

... More
Page No.63 Vol-2 9.26 - Providing and laying flooring with burnt stone slabs 10 cms thick, rough chistle dressed on sand bed 7.5 cms to 8 cms thick and pointed with cement mortar 1:3, , including cost of materials, sand, labour, curing complete as per specifications - - For Washing Platform

37.8

2488

94065.3

... More
Page No.122 vol-2 13.31.3 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall -25 mm nominal dia Pipes - - For Washing Platform

420

333

140238

... More
Page No.122 vol-2 13.31.4 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall -32 mm nominal dia Pipes - - For Washing Platform

574

420

241080

... More
Page No.Approved Rate - Providing and fixing in position Jaquar Hindware Parry ware bib cock of approved quality 20mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. Short body Cock - - For Washing Platform

70

1250

87500

... More
Page No.16 vol-1 2.5.2 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Ground Floor Chejjas - For Wardrobes

7.52

10418

78346.8944

... More
Page No.44 vol-2 8.16a - Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications - - For Wardrobes

300.94

1299

391191.906

... More
Page No.41 vol-2 8.4.2 - Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge - For Wardrobes

628.8

327

205994.88

... More
Page No.48 Vol-2 8.39 - Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge - For Wardrobes

829.43

133

110604.4905

... More
Page No.50 vol-2 8.51 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge - For Wardrobes

829.43

105

87090.15

... More
Page No.217 Vol-2 22.6 - Providing and supplying 19mm thick both side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand boxes,shelves,racks,almirah,cupboard and drawer etc. including necessary nails,screws etc. complete as per direction of Engineer-in-charge - For Wardrobes

358.68

1155

414275.4

... More
Page No.218 Vol-2 22.8 - Labour & installation charges for BWP ply:BWR ply:HDHMR: MDF & Particle board work of any thickness applicable for all types of work - For Wardrobes

423.36

2100

889056

... More
Page No.218 Vol-2 22.9(b) - Providing and fixing stainless steel 304 grade fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-incharge. 150 mm length - - For Wardrobes

366

1417

518805

... More
Page No.218 Vol-2 22.10 - Providing and fixing Stainless Steel 304 grade soft closing spring hinges at 0 degree hinges (hydraulic type) of approved make brand to cupboard shutters with full threaded steel screws including making necessary recess in board and finished etc. complete as per direction of Engineer-in-charge. - For Wardrobes

732

420

307440

... More
Page No.107 Vol-2 12.77.1 - Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete.

366

326

119517.3

... More
Page No.17 vol-3 3.7 - CC Road - Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction - For CC Road

216

110

23814

... More
Page No.17 vol-3 3.6 - Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 - - For CC Road

360

517

186354

... More
Page No.26 vol-3 4.17 - Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver grader in sub-base base course on well prepared surface and compacting with vibratory roller to achieve the desired density - - For CC Road

144

2686

386920.8

... More
Page No.50 vol-3 6.5 - Construction of M30 Grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with OPC @ 270 kg m3 and GGBS@ 90 kg m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures, curing compound, steel channels, finishing to lines and grades as per drawing - For CC Road

135

8230

1111178.25

... More
Page No.163 vol-3 17(C4) - Cutting transverse contraction joints 3 to 4 mm wide and depth 60mm in concrete slab using concrete cutting machine with diamond studded saw within 4-8 hours of casting of bay slab etc. complete including subsequent widening of the groove 8 to 10 mm. wide at top having depth of 15 mm. as directed by Engineer incharge - For CC Road

225

73

16537.5

... More
Page No.74 vol-3 8.42.8 - Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra)300 x 200 x 150 mm size - For CC Road

360

352

127008

... More
Page No.66 vol-3 8.10 - Painting Two Coats on New Concrete Surfaces- Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces - For CC Road

162

114

18540.9

... More
Vol-6(Part-III)Page-2 1.2.1 - Electrical Items - Concealed Conduit System Supplying heavy gauge PVC conduit pipe ...... mm dia. mm thick confirming to IS 2509 with suitable size bends, metal PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19-20 mm dia 2 mm thick

3280

66

216480

... More
Vol-6(Part-III)Page-2 1.2.2 - Concealed Conduit System Supplying heavy gauge PVC conduit pipe ...... mm dia. mm thick confirming to IS 2509 with suitable size bends, metal PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thick

2360

78

184080

... More
Vol-6(Part-III)Page-4 1.13 - Supplying And Fixing Metal Fan Box with Round Hook.

138

117

16146

... More
Vol-6(Part-III)Page-2 1.3.1 - Supplying heavy gauge PVC Conduit Pipe .... dia mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19 20 mm dia 2 mm thick

2240

68

152320

... More
Vol-6(Part-III)Page-2 1.3.2 - Supplying heavy gauge PVC Conduit Pipe .... dia mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25 mm dia 2 mm thick

1480

79

116920

... More
Vol-6(Part-III)Page-18 5.19.9 - Supplying and fixing regular MCB distribution boards on wall ood board flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase 3 phase single door with powder coated painting Made out of 14 SWG MS enclosure.-II - Double Door 12 Way SP & N

28

2329

65212

... More
Vol-6(Part-III)Page-8 3.4.1 - Supplying and flush mounting powder coated galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick Stone C.C wall 1-2 Way

70

138

9660

... More
Vol-6(Part-III)Page-8 3.4.3 - Supplying and flush mounting powder coated galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick Stone C.C wall. Make - Group "A" materials and as per the directions of Engineer in charge of the work.4-5 Way

44

177

7788

... More
Vol-6(Part-III)Page-8 3.4.4 - Supplying and flush mounting powder coated galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick Stone C.C wall 6 Way

238

220

52360

... More
Vol-6(Part-III)Page-8 3.4.5 - Supplying and flush mounting powder coated galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick Stone C.C wall 8 Way

58

261

15138

... More
Vol-6(Part-III)Page-8 3.4.6 - Supplying and flush mounting powder coated galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick Stone C.C wall 10-12 Way

42

319

13398

... More
Vol-6(Part-III)Page-8 3.4.7 - Supplying and flush mounting powder coated galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick Stone C.C wall 16 Way

36

363

13068

... More
Vol-6(Part-III)Page-5 2.2.1 - Supplying and wiring adopting loop system in existing PVC Conduit casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet gang box, the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block.complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box

438

269

117822

... More
Vol-6(Part-III)Page-5 2.2.2 - Supplying and wiring adopting loop system in existing PVC Conduit casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet gang box, the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block.complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box

354

379

134166

... More
Vol-6(Part-III)Page-5 2.2.3 - Supplying and wiring adopting loop system in existing PVC Conduit casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet gang box, the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block.complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box

330

555

183150

... More
Vol-6(Part-III)Page-5 2.3.2 - Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010 1.5 mm2

6740

26

175240

... More
Vol-6(Part-III)Page-5 2.3.3 - Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 mm2

15300

42

642600

... More
Vol-6(Part-III)Page-5 2.3.4 - Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 4 mm2

3580

63

225540

... More
Vol-6(Part-III)Page-5 2.3.5 - Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 6 mm2

1220

92

112240

... More
Vol-6(Part-III)Page-8 3.5.1 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal PVC box. 1 to 2 Module

70

137

9590

... More
Vol-6(Part-III)Page-8 3.5.3 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal PVC box.4 Module

44

175

7700

... More
Vol-6(Part-III)Page-8 3.5.4 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal PVC box. 6 Module

238

234

55692

... More
Vol-6(Part-III)Page-8 3.5.5 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal PVC box. 8 Module

58

284

16472

... More
Vol-6(Part-III) Page-8 3.5.6 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal PVC box. 10-12 Module

42

344

14448

... More
Vol-6(Part-III) Page-8 3.5.7 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal PVC box. 16 Module

36

397

14292

... More
Vol-6(Part-III)Page-9 3.6.1 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch

1886

102

192372

... More
Vol-6(Part-III)Page-9 3.6.2 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Two Way Switch

34

166

5644

... More
Vol-6(Part-III)Page-9 3.6.3 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Three Way socket

715

171

122265

... More
Vol-6(Part-III)Page-9 3.6.4 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module

135

357

48195

... More
Vol-6(Part-III)Page-9 3.6.9 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32A DP Switch

94

326

30644

... More
Vol-6(Part-III)Page-9 3.6.10 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6 16A Universal Socket

94

236

22184

... More
Vol-6(Part-III)Page-9 3.14.7 - Supplying And fixing replacing of 6 16 32A electrical accessories on existing switch board. 6A Batten Holder

895

74

66230

... More
Vol-6(Part-III)Page-30 6.1 - Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.

75

1492

111900

... More
Vol-6(Part-III)Page-30 6.3.1 - Supplying capacitor type ceiling fan complete with down rod blades,shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular model

135

2984

402840

... More
Vol-6(Part-III)Page-30 6.5.1 - Supplying wall mounting fan suitable to operate at single- phase 230v AC. supply. 300 mm Sweep

8

2492

19936

... More
Vol-6(Part-III)Page-44 11.5.2 - Supply of round square recess surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium diecast eye ball & LED Lamp position retained by circular wire spring,with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50 60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical conditionLED square or round down light 10-12W

8

885

7080

... More
Vol-6(Part-III)Page-45 11.6.3 - Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322 IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition-LED modular down light 2'x2' 36 W

8

4553

36424

... More
Vol-6(Part-III)Page-43 11.3.2 - Supplying of .....feet -PVC Batten with integrated LED tube 20 22 W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220- 240V@ 50 60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.-LED light fitting 1 x 4' - 20 22 W

680

690

469200

... More
Vol-6(Part-III)Page-47 11.11.7 - Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322 IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.18W, 6500K

155

426

66030

... More
Vol-6(Part-III)Page-56 13.7.1 - Fixing all types and all capacities of fluorescent false ceiling spot light CFL LED fittings indoor on the wall ceiling rafters girders using 23 0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps.On wall ceiling Rafter Girders

696

122

84912

... More
Vol-6(Part-III)Page-57 13.10 - Fixing a ceiling Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 0.0076 inch PVC insulated twin twisted copper wire and wiring.

143

171

24453

... More
Vol-6(Part-III)Page-57 13.12 - Extra length of GI pipe of class B 19 mm dia for down rod.

64

197

12608

... More
Vol-6(Part-III)Page-57 13.14 - Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23 0.0076 inch PVC insulated twin core wire.

75

492

36900

... More
Vol-6(Part-III)Page-48 12.2.1 - Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell

5

246

1230

... More
Vol-6(Part-III)Page-17 5.18.4 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898-6-32 A DP

144

739

106416

... More
Vol-6(Part-III)Page-18 5.20.1 - Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240 450V upto 300mA sensitivity on existing wood panel board.16A-25A 2 pole

28

4277

119756

... More
Vol-6(Part-III)Page-9 3.6.11 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV Telephone Socket

10

156

1560

... More
Vol-6(Part-III)Page-36 8.2.2 - Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable.-2Pair

440

21

9240

... More
Vol-6(Part-III)Page-36 8.1 - Supplying and drawing UTP-CAT 6E LAN cable.

150

38

5700

... More
Vol-6(Part-III)Page-36 8.3 - Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6.

260

44

11440

... More
Vol-6(Part-III)Page-35 7.4.3 - Supplying,installation,testing and commissioning of solar hotwater heater comprising of high quality Evacuated Glass Tube (E GT) with absorber coating collector of size 58x1800mm. Innertank Material- Stainless steel 304-L Grade with Aluminium Stuccocladding made of Highquality PUF insulation tominimize sheat loss and hold water Temperature upto 72Hrs... with appropriatecapacityelectricalbackup arrangement excluding inlet and out let pipes. Fitted with Sacrificial Anode-300 L - 29 nos Tubes

24

51528

1236672

... More
Vol-6(Part-III)Page-38 9.2.3 - UPS with Batteries - Supplying,erecting,testing & commissioning of 2 KVAOFF-LINE UPS system suitable for operationon 230V,50Hz, A C supply, with all accessories complete and Excluding batteries and wiring complete.- 2 KVAOFF-LINE UPS

7

21293

149051

... More
Vol-6(Part-III)Page-32 6.22 - Extra for Fabrication supply and fixing of Stand fabricated using slotted angle L angle of size 6mm x 50mm for mounting out door indoor A.C. unit Batteries.

7

4807

33649

... More
Vol-6(Part-III)Page-38 9.4.6 - Supplying,installation,testing & commissioning of 12V..AH batteries in polypropylene container for D.G.sets.Lowmaintenancebatteries, plate type.-150 AH capacity

14

28187

394618

... More
Vol-6(Part-III)Page-14 5.7.3 - Panelling work - Supplying & fixing of Porcelain fuse channel with cut out on existing wooden panel using necessary nuts, bolts and washers. 63 A

12

401

4812

... More
Vol-6(Part-III)Page-17 5.17.2 - Supplying and fixing regular MCCB distribution Panelcon firming to IS IEC61439-3 and IK09 test edasper IS IEC62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall woodboard flushmounting using requiredclA, bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB' sasanin comerfor 3phase Double door with necessary busbar completely wired touseon 440V3 phase 4wire powder coated painting etc., complete witha provision for fixing of single three phase suitable capacity MCB' sas outgoings confirming to IS IEC 60898 - 2.-8 Way

3

12605

37815

... More
Vol-6(Part-III)Page-15 5.12.1 - Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SMEnclosure Sheet Metal Execution) 63 A

4

6881

27524

... More
Vol-6(Part-III)Page-17 5.15.9 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.100 A 25 kA

7

8487

59409

... More
Vol-6(Part-III)Page-17 5.18.7 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898-6-32 A TPN

27

1717

46359

... More
Vol-6(Part-III)Page-18 5.21 - Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay auto manual reset facility suitable to mount on DIN rail flush mounting on panel board.

4

9255

37020

... More
Vol-6(Part-III)Page-19 5.29 - Supplying, fixing and wiring 3 Phase Digital A mmeter Voltmeter

4

1425

5700

... More
Vol-6(Part-III)Page-19 5.34 Vol-6 - Supplying, fixing and wiring 50 5 to 400 5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound.

12

562

6744

... More
Vol-6(Part-III)Page-19 5.38 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230 440VAC. 50 Hz 12 24V D.C.

12

515

6180

... More
Vol-6(Part-III)Page-20 5.40.1 - Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic FRP DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete-100 A 4 x 30 x 6 mm Aluminium Strips

3.2

2465

7888

... More
Vol-6(Part-III)Page-20 5.41.1 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint-40 x 40 x 6 mm

32

305

9760

... More
Vol-6(Part-III)Page-20 5.42.2 - Fabricating supplying and mounting MS box made out SWG suitable for floor wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete-16 SWG

256000

-

110080

... More
Vol-6(Part-III)Page-3 1.9.2 - Supplying PVC flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 25 mm

48

22

1056

... More
Vol-6(Part-III)Page-55 12.58.7 - UG Cable - GI Copper strips for grounding connections, using necessary fixing materials as required.25 x 3 mm Copper strip

88

570

50160

... More
Vol-6(Part-III)Page-54 12.56 - Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm allround the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia

24

3510

84240

... More
Vol-6(Part-II)Page-13 32.05 - Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms Kms (Max) as per IS-3975. 4 core 16 sq mm

0.64

141842

90778.88

... More
Vol-6(Part-II)Page-13 32.11 - Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms Kms (Max) as per IS-3975. 50 Sqmm, 3.5 Core, (18 GI Strips - 4 x 0.8 mm)

0.14

178973

25056.22

... More
Vol-6(Part-II)Page-13 32.13 - Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975. 70 Sqmm, 3.5 Core, (18 GI Strips - 4 x 0.8 mm)

0.48

317912

152597.76

... More
Vol-6(Part-II)Page-52 21.05 - Laying of LT cable in Existing Trench GI pipe Stone Ware RCC Hume pipe using Wooden Aluminum Rollers as directed by the departmental staff. 2.5 to 25 Sqmm

0.64

20886

13367.04

... More
Vol-6(Part-II)Page-52 21.06 - Laying of LT cable in Existing Trench GI pipe Stone Ware RCC Hume pipe using Wooden Aluminum Rollers as directed by the departmental staff. 35 to 95 Sqmm

0.62

31139

19306.18

... More
CSR Page-6 1.6.1 Vol-1 - Earth work excavation for pipelines cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m

466

484

225544

... More
Vol-6(Part-II)Page-28 63.04 - Supplying and fixing of heavy duty Brass Cable Gland. 45 mm dia

24

197

4728

... More
Vol-6(Part-III)Page-46 11.8.3 - Street light - Supply of 70 watts LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage Overload, short circuit miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50 60Hz application. Compliance to IS 10322 IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency 1301m w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark name shall be Engraved Embossing on the die cast housing Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree Nichia Lumileds Osram make LED Source.-LED Streetlight 70W

20

5992

119840

... More
Vol-6(Part-III)Page-56 13.1.1 Vol-6 - Supplying and Fixing of mm dia class A GI pipe bracket upto 2ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires.Using 25mm dia G.I.Pipe

20

978

19560

... More
CSR page-157 13.40.1 Vol-5 - Pump set - Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments.2 HP, Size 65x50 Head 13M, Discharge 462 LPM

4

15610

62440

... More
CSR page-152 13.13.6 Vol-5 - Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. 5.00 HP - 90 LPM @ 110 m = 15 STG Outlet Dia - 2.00"etc. complete

4

32137

128548

... More
CSR page-156 13.32 Vol-5 - Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work.

4

6500

26000

... More
Vol-6(Part-III)Page-7 2.6.1 - Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990. 3C x 2.5 sq mm

160

117

18720

... More
Vol-6(Part-III)Page-7 2.6.2 - Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990. 3C x 4 sq mm

810

168

136080

... More
CSR page-98 9.5.1 Vol-5 - Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 16.0-63mm dia

700

327

228900

... More
CSR Page-155 13.23.1 Vol-5 - Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter Upto 3 HP pumps

4

6500

26000

... More
CSR Page-155 13.23.2 Vol-5 - Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter above 3 to 6 HP pumps

4

9550

38200

... More
Csr Page-154 13.24.1 Vol-5 - Supply and delivery at site of brand new best make gate valve as per IS 778 1984 with ISI Mark and as per its latest amendments 50 mm dia.

8

1250

10000

... More
CSR Page-154 13.25.1 Vol-5 - Supply and delivery at site of brand new best makeNon -return valve as per IS 778/1984 with ISI Mark and as per its latest amendments 50 mm dia.

8

1250

10000

... More
Vol-6(Part-III)Page-54 12.57 - External Electrification : Supplyin,gfixing and wiring earth electrode for grounding of lifts, transformers, DGsets etc. using 40mm dia 2.9mm thick 2.5m long GI pipe with GI funnel with meshand suitable size reducer fixed on the top of theear the lectrode. The funnel should been close dina CC chamber of 400x400x400 mm with acastiron cover. Theear the lectrode shall havest aggered holes of 12mm dia and theel ectrode should be covered 150mm all-round with alternatelayers of salt and charcoal from the bottom of the CC chamber. The connection from theelectrode is to be established through GI strip using GI bolts and nuts.

16

4256

68096

... More
BSR 18-19 41.10 - Supplying & fixing M.S rectangular pole made of 2 equal angles 65 x 65 x 6 mm welded together & fixed in C.C (1:2:4) with 2 nos 16 mm dia MS . Hold fast rods each of length 25cms. Including cost of all materials cutting, bending scaffolding wherever neccessary, nicely finishing the welded joints with all lead lifts and as per the directions of the engineer-in-charge of the work and including providing 2 coats of approved quality paint over one coat of shop painting ( excluding cost of earthwork and concrete) including cost of materials, labour, HOM complete as per specifications.

88

859

75592

... More
CSR Page-95 11.58 Vol-2 - Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineerin-charge. (Made of G.I. wire of dia 4 mm)

144

803

115632

... More
CSR Page-15 2.1.6 Vol-1 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates

1.44

6243

8989.92

... More
Vol-6(Part-III)Page-20 5.41.1 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint-40 x 40 x 6 mm

72

305

21960

... More
Vol-6(Part-II)Page-07 13.02 - Distribution Transformer - 3 Phase,11kV 433V - Amorphous Core with Oil as per IS-1180 (Part-1): 2014 OPEN BUSHING TYPE 63kVA, Aluminium Wdg, Star 2 (5 Star)

4

166641

666564

... More
Vol-6(Part-II)Page-09 18.01 - LT Distribution Box for 100 kVA DTC with MCCB's (Sheet Metal) (Dwg No. BESCOM GM QS&S 58 Dtd 24.11.2018)

4

22686

90744

... More
Vol-6(Part-II)Page-09 17.01 - LT Protection kit (Dwg No. BESCOM GM QS&S 10 Dtd 24.11.2018

4

2023

8092

... More
Vol-6(Part-II)Page-10 21.08 - Double Pole TC Sets for erection of Transformers on RCC PSCC 9 Mtrs Long Poles as per IS-1977, For 100 300kVA 4 5 Star Rated Transformers using 9 mtr RCC Pole 145Kg WL - GI

4

30694

122776

... More
Vol-6(Part-II)Page-11 24.01 - GOS as per IS-9921, IS-1977 11kV, 200 Amps Single Break GOS (Dwg No. BESCOM GM QS&S 23 Dtd 24.11.2018)

8

9450

75600

... More
Vol-6(Part-II)Page-12 25.01 - DOLO Cutouts as per IS-9385, Part-1 to 3, 11kV DOLO Cutouts Conventional to Erstwhile KEB Specification (Dwg No. BESCOM GM QS&S 20 Dtd 24.11.2018)

4

5875

23500

... More
Vol-6(Part-II)Page-03 1.01 - RCC Pole - 9 Mtr Long, 150 Kg WL Sq Section (Dwg No. BESCOM GM QS&S 51 Dtd 24.11.2018) as per IS-785

4

7076

28304

... More
Vol-6(Part-II)Page-03 1.06 - PSCC Pole - 9 Mtr Long, 200 Kg WL (Dwg No.(Dwg No. BESCOM GM QS&S 50 Dtd 24.11.2018) as per REC Standards

11

4199

46189

... More
Vol-6(Part-II)Page-03 2.02 - Cross Arms (MS & GI) as per IS-1977 11kV Horizontal X Arms - Galvanised Iron (GI)

12

487

5844

... More
Vol-6(Part-II)Page-03 2.03 - Cross Arms (MS & GI) as per IS-1977 11kV Special 3 Pin X Arm - MS (Dwg No. BESCOM GM QS&S 03 Dtd 24.11.2018)

4

879

3516

... More
Vol-6(Part-II)Page-04 2.12 - HT ST Support 50x6mm Flat - GI

16

121

1936

... More
Vol-6(Part-II)Page-05 6.06 - 11kV, 5KN Composite Polymeric Pin Insulator (24mm dia FRP Rod)

72

205

14760

... More
Vol-6(Part-II)Page-05 6.10 - 11kV, 45kN Polymeric Insulator

36

186

6696

... More
Vol-6(Part-II)Page-03 24.a - Guy set complete with No.15 strain insulator & Cocreting matrials

8

593

4744

... More
Vol-6(Part-II)Page-45 5.10 - Fixing of GUY Set with break insulator making use of 7 3.15 mm (7 10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT)

8

266

2128

... More
Vol-6(Part-II)Page-05 7.02 - Rabbit ACSR(6 3.35 mm Al + 1 3.35 mm St), Std Wt: 214 Kg KM

2.84

46234

131304.56

... More
Vol-6(Part-II)Page-03 2.16 - Spiral Earth Electrode

24

239

5736

... More
Vol-6(Part-II)Page-03 2.15 - EG Stirrup (MS) with GI wire lacing

24

276

6624

... More
Vol-6(Part-II)Page-32 68.17 - Caution Danger Board

8

150

1200

... More
Vol-6(Part-II)Page-04 4.02 - Anti climbing device GI Barbed wire (12mtrs Kg)

8

89

712

... More
Vol-6(Part-III)Page-19 5.31 - Supplying and fixing Electronic Trivector Meter (ETV) suitable for operation LT operation and -CT operated meter in polycarbonate body in class 0.5 accuracy as per IS 14697 and completely wired.

4

4390

17560



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.