Karnataka State Police Housing And Infrastructure Development Corporation Limited Tender

... More
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Karnataka State Police Housing And Infrastructure Development Corporation Limited - KSPHCL Tender

Civil And Construction
Building Construction
Opening Date4 Feb 2022
Closing Date16 Feb 2022
Tender Amount₹ 3,03,63,601 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Earth work excavation for foundation of structures by mechanical means as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising / transporting the remaining earth locally upto 1.00km lead. (Depth upto 3.00 Mts) -In all types of soil ---- as per directions of engineer in charge of work.

61.493

-

3197.64

... More
KSRB 4-1.3 : Providing and laying in position plain cement concrete of mix 1:4:8 with OPC cement @ 180kgs, with 40mm and down size graded granite metal coarse aggregates @0.85cum and fine aggregates @ 0.57cum machine mixed, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, including cost of all materials, labour, HOM of machinery, curing complete as per specifications. Specification No. KBS 4.1, 4.2 ---- as per directions of engineer in charge of work.

54.5328

-

273645.59

... More
KSRB 4.2.2 : Providing and laying in position reinforced cement concrete of Design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregtes @ 0.460 cum, with super plasticisers @ 3 liters confirming to is 9103-1999 reafirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in foundation for footings, pedastals, retaining walls, return walls, walls (any thickness) including attached pilasters, columnspillars, posts, struts, buttresses, bed blocks, anchor blocks & plinths etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 ---- as per directions of engineer in charge of work.

57.1455

-

322014.89

... More
KSRB 4-6.1 : Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for foundations, footings, bases of columns for mass concrete including cost of all materials, labour complete as per specificaitons. Specification No. KBS 4.6.2 ---- as per directions of engineer in charge of work.

106.21

-

27827.02

... More
KSRB 4.2.8: Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in ground floor level for roof slabs, staircase, lintles, and beams retaining walls, return walls, walls (any thickness) including attached plasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 ---- as per directions of engineer in charge of work.

10.0327

-

58871.88

... More
KSRB 4.2.8: Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in ground floor level for roof slabs, staircase, lintles, and beams retaining walls, return walls, walls (any thickness) including attached plasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 ---- as per directions of engineer in charge of work.

7.1346

-

42293.91

... More
KSRB 4.2.8: Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in ground floor level for roof slabs, staircase, lintles, and beams retaining walls, return walls, walls (any thickness) including attached plasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 ---- as per directions of engineer in charge of work.

4.9029

-

29358.57

... More
KSRB 4-6.5 : Providing and removing centering, shuttering, strutting, propping etc., for columns, pillars, post and struts, square / rectangular/ polygon in plan including cost of all materials, labour complete as per specifications. Specification No. KBS 4.6.2 ---- as per directions of engineer in charge of work.

131.7226

-

60065.51

... More
KSRB 4-6.5 : Providing and removing centering, shuttering, strutting, propping etc., for columns, pillars, post and struts, square / rectangular/ polygon in plan including cost of all materials, labour complete as per specifications. Specification No. KBS 4.6.2 ---- as per directions of engineer in charge of work.

94.403

-

43047.77

... More
KSRB 4-6.5 : Providing and removing centering, shuttering, strutting, propping etc., for columns, pillars, post and struts, square / rectangular/ polygon in plan including cost of all materials, labour complete as per specifications. Specification No. KBS 4.6.2 ---- as per directions of engineer in charge of work.

94.7998

-

43228.71

... More
KSRB 5.1-3 : Providing and constructing granite / trap / basalt rubble stone masonry in foundation with cement mortar 1:6 (uncoursed), bond stones at two m. apart in each course including cost of materials, labour, curing complete as per specifications.KBS 5.1.12 ---- as per directions of engineer in charge of work.

68.682

-

239837.54

... More
KSRB 5.3-3 : Providing and constructing granite / trap / basalt size stone masonry in basement with cement mortar 1:6, edges of stones chistle dressed in courses not less than 15 cms high, bond stones at two m. apart in each course including cost of materials, labour, curing complete as per specifications. KBS 5.1.13 ---- as per directions of engineer in charge of work.

38.3625

-

223461.56

... More
KSRB 2.3 : Filling available excavated earth ( excluding rock ) in sides of foundations upto plinth in layers not exceeding 20 cms. in depth, compacting each deposited layer by ramming after watering with lead upto 50 m. and lift upto 1.5 m. including cost of all labour complete as per specifications. specification. No. KBS 2.9 ---- as per directions of engineer in charge of work.

61.493

-

12360.09

... More
KSRB 2.5 : Earthwork excavation in all soil deposits and filling sides of foundation upto plinth in layers not exceeding 20cms. in depth, compacting each deposited layer by ramming after watering with all lead and lift including cost of all labour complete as per specifications. specification. No. KBS 2.9.9 / 2.9.10.1 / 2.1.1 ---- as per directions of engineer in charge of work.

447.522

-

180351.37

... More
KSRB 4.2.2 : Providing and laying in position reinforced cement concrete of Design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregtes @ 0.460 cum, with super plasticisers @ 3 liters confirming to is 9103-1999 reafirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in foundation for footings, pedastals, retaining walls, return walls, walls (any thickness) including attached pilasters, columnspillars, posts, struts, buttresses, bed blocks, anchor blocks & plinths etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 ---- as per directions of engineer in charge of work.

14.0591

-

79223.03

... More
KSRB 4-6.7 :Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for sides and soffits of beams, beam haunchings, cantilever girders, bressumers and lintels not exceeding 1m in depth including cost of all materials, labour complete as per specifications. Specification No. KBS 4.6.2 ---- as per directions of engineer in charge of work.

122.2516

-

35697.47

... More
KSRB 6-1.3 : Providing and constructing burnt brick masonry for basement and superstructure with approved quality of non-modular bricks of standard size of class designation 3.5Newton per sqmm with cement mortar1:6 including cost of materials, labour charges, scaffolding, curing complete as per specifications. Specification No. KBS 6.2 ---- as per directions of engineer in charge of work.

55.1046

-

323519.11

... More
KSRB 6-1.3 : Providing and constructing burnt brick masonry for basement and superstructure with approved quality of non-modular bricks of standard size of class designation 3.5Newton per sqmm with cement mortar1:6 including cost of materials, labour charges, scaffolding, curing complete as per specifications. Specification No. KBS 6.2 ---- as per directions of engineer in charge of work.

49.5127

-

293659.82

... More
KSRB 6-1.3 : Providing and constructing burnt brick masonry for basement and superstructure with approved quality of non-modular bricks of standard size of class designation 3.5Newton per sqmm with cement mortar1:6 including cost of materials, labour charges, scaffolding, curing complete as per specifications. Specification No. KBS 6.2 ---- as per directions of engineer in charge of work.

45.725

-

273938.48

... More
KSRB 6-8.3 :Construction of partition wall 10 cms thick with ground moulded modular burnt bricks of class designation 3.5Newton per sqmm with cement mortar 1:4 including cost of materials, labour charges, scaffolding, curing complete as per specifications. Specification No. KBS 6.2 ---- as per directions of engineer in charge of work.

158.0722

-

109227.89

... More
KSRB 6-8.3 :Construction of partition wall 10 cms thick with ground moulded modular burnt bricks of class designation 3.5Newton per sqmm with cement mortar 1:4 including cost of materials, labour charges, scaffolding, curing complete as per specifications. Specification No. KBS 6.2 ---- as per directions of engineer in charge of work.

202.5847

-

141201.54

... More
KSRB 6-8.3 :Construction of partition wall 10 cms thick with ground moulded modular burnt bricks of class designation 3.5Newton per sqmm with cement mortar 1:4 including cost of materials, labour charges, scaffolding, curing complete as per specifications. Specification No. KBS 6.2 ---- as per directions of engineer in charge of work.

120.0434

-

84390.51

... More
KSRB 4-1.7 : Providing and laying in position plain cement concrete of mix 1:3:6 with OPC cement @ 220kgs, with 20mm and down size graded granite metal coarse aggregates @0.84cum and fine aggregtes @ 0.56cum, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, plinth and cills, ncluding cost of all materials, labour, HOM of machinery, curing complete as per specifications. Specification No. KBS 4.1, 4.2 ---- as per directions of engineer in charge of work.

1.5083

-

7997.01

... More
KSRB 4-1.7 : Providing and laying in position plain cement concrete of mix 1:3:6 with OPC cement @ 220kgs, with 20mm and down size graded granite metal coarse aggregates @0.84cum and fine aggregtes @ 0.56cum, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, plinth and cills, ncluding cost of all materials, labour, HOM of machinery, curing complete as per specifications. Specification No. KBS 4.1, 4.2 ---- as per directions of engineer in charge of work.

1.7417

-

9339

... More
KSRB 4-1.7 : Providing and laying in position plain cement concrete of mix 1:3:6 with OPC cement @ 220kgs, with 20mm and down size graded granite metal coarse aggregates @0.84cum and fine aggregtes @ 0.56cum, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, plinth and cills, ncluding cost of all materials, labour, HOM of machinery, curing complete as per specifications. Specification No. KBS 4.1, 4.2 ---- as per directions of engineer in charge of work.

2.0815

-

11285.89

... More
KSRB 4.2.8: Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in ground floor level for roof slabs, staircase, lintles, and beams retaining walls, return walls, walls (any thickness) including attached plasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 ---- as per directions of engineer in charge of work.

3.8732

-

22727.94

... More
KSRB 4.2.8: Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in ground floor level for roof slabs, staircase, lintles, and beams retaining walls, return walls, walls (any thickness) including attached plasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 ---- as per directions of engineer in charge of work.

14.8669

-

87238.97

... More
KSRB 4.2.8: Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in ground floor level for roof slabs, staircase, lintles, and beams retaining walls, return walls, walls (any thickness) including attached plasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 ---- as per directions of engineer in charge of work.

2.9423

-

17265.42

... More
KSRB 4.2.8: Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in ground floor level for roof slabs, staircase, lintles, and beams retaining walls, return walls, walls (any thickness) including attached plasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 ---- as per directions of engineer in charge of work.

3.7399

-

22170.13

... More
KSRB 4.2.8: Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in ground floor level for roof slabs, staircase, lintles, and beams retaining walls, return walls, walls (any thickness) including attached plasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 ---- as per directions of engineer in charge of work.

12.5109

-

74164.62

... More
KSRB 4.2.8: Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in ground floor level for roof slabs, staircase, lintles, and beams retaining walls, return walls, walls (any thickness) including attached plasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 ---- as per directions of engineer in charge of work.

2.9423

-

17441.95

... More
KSRB 4.2.8: Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in ground floor level for roof slabs, staircase, lintles, and beams retaining walls, return walls, walls (any thickness) including attached plasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 ---- as per directions of engineer in charge of work.

2.2983

-

13762.22

... More
KSRB 4.2.8: Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in ground floor level for roof slabs, staircase, lintles, and beams retaining walls, return walls, walls (any thickness) including attached plasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 ---- as per directions of engineer in charge of work.

5.332

-

31928.02

... More
KSRB 4-6.7 :Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for sides and soffits of beams, beam haunchings, cantilever girders, bressumers and lintels not exceeding 1m in depth including cost of all materials, labour complete as per specifications. Specification No. KBS 4.6.2 ---- as per directions of engineer in charge of work.

41.1346

-

12011.3

... More
KSRB 4-6.7 :Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for sides and soffits of beams, beam haunchings, cantilever girders, bressumers and lintels not exceeding 1m in depth including cost of all materials, labour complete as per specifications. Specification No. KBS 4.6.2 ---- as per directions of engineer in charge of work.

170.3149

-

49731.95

... More
KSRB 4-6.11 :Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for Stairs (excluding landing) except spiral staircase including cost of all materials, labour complete as per specificaiton. Specification No. KBS 4.6.2 ---- as per directions of engineer in charge of work.

20.5894

-

11262.4

... More
KSRB 4-6.7 :Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for sides and soffits of beams, beam haunchings, cantilever girders, bressumers and lintels not exceeding 1m in depth including cost of all materials, labour complete as per specifications. Specification No. KBS 4.6.2 ---- as per directions of engineer in charge of work.

40.4326

-

11806.32

... More
KSRB 4-6.7 :Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for sides and soffits of beams, beam haunchings, cantilever girders, bressumers and lintels not exceeding 1m in depth including cost of all materials, labour complete as per specifications. Specification No. KBS 4.6.2 ---- as per directions of engineer in charge of work.

163.1868

-

47650.55

... More
KSRB 4-6.11 :Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for Stairs (excluding landing) except spiral staircase including cost of all materials, labour complete as per specificaiton. Specification No. KBS 4.6.2 ---- as per directions of engineer in charge of work.

20.6271

-

11283.02

... More
KSRB 4-6.7 :Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for sides and soffits of beams, beam haunchings, cantilever girders, bressumers and lintels not exceeding 1m in depth including cost of all materials, labour complete as per specifications. Specification No. KBS 4.6.2 ---- as per directions of engineer in charge of work.

24.0346

-

7018.1

... More
KSRB 4-6.7 :Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for sides and soffits of beams, beam haunchings, cantilever girders, bressumers and lintels not exceeding 1m in depth including cost of all materials, labour complete as per specifications. Specification No. KBS 4.6.2 ---- as per directions of engineer in charge of work.

69.5481

-

20308.05

... More
KSRB 4.2.10 : Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 24kgs, with 12mm and down size graded granite metal coarse aggregates @0.05175cum and fine aggregtes @ 0.0345cum, with superplastisiser @0.225lts, machine mixed, well compacted for plain chajja of 7.5 cms. average thickness, upto ground floor level, including cost of all materials, labour, HOM of machinery, finishing, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 ---- as per directions of engineer in charge of work.

16.32

-

7148.16

... More
KSRB 4.2.10 : Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 24kgs, with 12mm and down size graded granite metal coarse aggregates @0.05175cum and fine aggregtes @ 0.0345cum, with superplastisiser @0.225lts, machine mixed, well compacted for plain chajja of 7.5 cms. average thickness, upto ground floor level, including cost of all materials, labour, HOM of machinery, finishing, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 ---- as per directions of engineer in charge of work.

21

-

9303

... More
KSRB 4.2.10 : Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 24kgs, with 12mm and down size graded granite metal coarse aggregates @0.05175cum and fine aggregtes @ 0.0345cum, with superplastisiser @0.225lts, machine mixed, well compacted for plain chajja of 7.5 cms. average thickness, upto ground floor level, including cost of all materials, labour, HOM of machinery, finishing, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 ---- as per directions of engineer in charge of work.

8.16

-

3655.68

... More
KSRB 4-6.10 :Providing and removing centering, shuttering, strutting, propping etc., for chajjas, corbels etc., including edges including cost of all materials, labour complete as per specifications. Specification No. KBS 4.6.2 ---- as per directions of engineer in charge of work.

16.32

-

5352.96

... More
KSRB 4-6.10 :Providing and removing centering, shuttering, strutting, propping etc., for chajjas, corbels etc., including edges including cost of all materials, labour complete as per specifications. Specification No. KBS 4.6.2 ---- as per directions of engineer in charge of work.

21

-

6888

... More
KSRB 4-6.10 :Providing and removing centering, shuttering, strutting, propping etc., for chajjas, corbels etc., including edges including cost of all materials, labour complete as per specifications. Specification No. KBS 4.6.2 ---- as per directions of engineer in charge of work.

8.16

-

2676.48

... More
KSRB 4-2.12 : Extra for providing throating or drip moulding to R.C.C. chajja with plastering ( labour charges only ) as per specifications. Specification No. KBS ---- as per directions of engineer in charge of work.

45.2

-

1491.6

... More
KSRB 4-2.12 : Extra for providing throating or drip moulding to R.C.C. chajja with plastering ( labour charges only ) as per specifications. Specification No. KBS ---- as per directions of engineer in charge of work.

54.2

-

1788.6

... More
KSRB 4-2.12 : Extra for providing throating or drip moulding to R.C.C. chajja with plastering ( labour charges only ) as per specifications. Specification No. KBS ---- as per directions of engineer in charge of work.

28

-

924

... More
Providing RCC loft (atta) 7.5cms thick with cement concrete design mix M20 using clean granite or trap jelly of 20mm and down size with necessary reinforcements at 20cms centre to centre as per design including form work, centring, curing, etc., complete (exclusive of cost of steel and fabrication charges). ---- as per directions of engineer in charge of work.

18.486

-

7893.52

... More
Providing RCC loft (atta) 7.5cms thick with cement concrete design mix M20 using clean granite or trap jelly of 20mm and down size with necessary reinforcements at 20cms centre to centre as per design including form work, centring, curing, etc., complete (exclusive of cost of steel and fabrication charges). ---- as per directions of engineer in charge of work.

31.653

-

13515.83

... More
Providing RCC loft (atta) 7.5cms thick with cement concrete design mix M20 using clean granite or trap jelly of 20mm and down size with necessary reinforcements at 20cms centre to centre as per design including form work, centring, curing, etc., complete (exclusive of cost of steel and fabrication charges). ---- as per directions of engineer in charge of work.

9.126

-

3896.8

... More
KSRB 4-5 : Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixing chicken mesh for drop chajja, facia, backing to cup boards including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specifications. Specification No. KBS ---- as per directions of engineer in charge of work.

39.66

-

41920.62

... More
Providing and fixing RCC slabs 5 cms thick for wall shelves with 12mm and down size jelly cement concrete design mix M20 including CM 1:3 plaster finishing, curing etc., complete (excluding the cost of steel and fabrication charges ---- as per directions of engineer in charge of work.

25.5

-

15555

... More
Providing and fixing RCC slabs 5 cms thick for wall shelves with 12mm and down size jelly cement concrete design mix M20 including CM 1:3 plaster finishing, curing etc., complete (excluding the cost of steel and fabrication charges ---- as per directions of engineer in charge of work.

40.29

-

24576.9

... More
Providing and fixing RCC slabs 5 cms thick for wall shelves with 12mm and down size jelly cement concrete design mix M20 including CM 1:3 plaster finishing, curing etc., complete (excluding the cost of steel and fabrication charges ---- as per directions of engineer in charge of work.

24.51

-

14951.1

... More
KSRB 4.2.8: Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in ground floor level for roof slabs, staircase, lintles, and beams retaining walls, return walls, walls (any thickness) including attached plasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 ---- as per directions of engineer in charge of work.

31.5265

-

184997.5

... More
KSRB 4.2.8: Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in ground floor level for roof slabs, staircase, lintles, and beams retaining walls, return walls, walls (any thickness) including attached plasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 ---- as per directions of engineer in charge of work.

31.3316

-

185733.72

... More
KSRB 4.2.8: Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in ground floor level for roof slabs, staircase, lintles, and beams retaining walls, return walls, walls (any thickness) including attached plasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 ---- as per directions of engineer in charge of work.

16.7374

-

100223.55

... More
KSRB 4-6.3 : Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for flat surface such as suspended floors, roofs, landings, balconies and likes, thickness above 200 mm including cost of all materials, labour complete as per Specification. Specification No. KBS 4.6.2 ---- as per directions of engineer in charge of work.

252.8196

-

113010.36

... More
KSRB 4-6.3 : Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for flat surface such as suspended floors, roofs, landings, balconies and likes, thickness above 200 mm including cost of all materials, labour complete as per Specification. Specification No. KBS 4.6.2 ---- as per directions of engineer in charge of work.

218.0425

-

97465

... More
KSRB 4-6.3 : Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for flat surface such as suspended floors, roofs, landings, balconies and likes, thickness above 200 mm including cost of all materials, labour complete as per Specification. Specification No. KBS 4.6.2 ---- as per directions of engineer in charge of work.

118.3326

-

52894.67

... More
KSRB 4-1.5 : Providing and laying in position plain cement concrete of mix M20 with OPC cement @ 300kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregtes @ 0.43cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, plinth and cills, including cost of all materials, labour, HOM of machinery, curing complete as per specifications. Specification No. KBS 4.1, 4.2 ---- as per directions of engineer in charge of work.

3.465

-

18347.18

... More
KSRB 4-1.5 : Providing and laying in position plain cement concrete of mix M20 with OPC cement @ 300kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregtes @ 0.43cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, plinth and cills, including cost of all materials, labour, HOM of machinery, curing complete as per specifications. Specification No. KBS 4.1, 4.2 ---- as per directions of engineer in charge of work.

15.5142

-

84009.39

... More
For roof slab & terraces Providing & applying water proofing to roof slab, terraces, landscape area, podium etc., using modified polyurethane cures (conforming to ASTM C836-84) to give a tough elastomeric waterproof membrane on the surface. The surface shall be cleaned free from dust and other particle before usage. standards & methodology : This compound has a medium viscosity grade with 620% of elongation and shall be done either by roller application/brush application/ spray. This will be applied for a thickness of 1.3mm first layer 0.5mm & 2nd layer 0.8mm. After applying the 2nd layer sand sprinkle shall be done to provide mechanical key. ---- as per directions of engineer in charge of work.

46.2

-

32340

... More
For roof slab & terraces Providing & applying water proofing to roof slab, terraces, landscape area, podium etc., using modified polyurethane cures (conforming to ASTM C836-84) to give a tough elastomeric waterproof membrane on the surface. The surface shall be cleaned free from dust and other particle before usage. standards & methodology : This compound has a medium viscosity grade with 620% of elongation and shall be done either by roller application/brush application/ spray. This will be applied for a thickness of 1.3mm first layer 0.5mm & 2nd layer 0.8mm. After applying the 2nd layer sand sprinkle shall be done to provide mechanical key. ---- as per directions of engineer in charge of work.

206.856

-

144799.2

... More
KSRB15-3.9 :Providing 18mm thick cement plaster in single coat with cement mortar 1:6, to brick masonry including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. ---- as per directions of engineer in charge of work.

295.769

-

70393.02

... More
KSRB15-3.9 :Providing 18mm thick cement plaster in single coat with cement mortar 1:6, to brick masonry including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. ---- as per directions of engineer in charge of work.

231.424

-

57856

... More
KSRB15-3.9 :Providing 18mm thick cement plaster in single coat with cement mortar 1:6, to brick masonry including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. ---- as per directions of engineer in charge of work.

308.3605

-

80790.45

... More
KSRB15-3.3 : Providing 12mm thick cement plaster in single coat with cement mortar 1:6, to brick masonry including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. ---- as per directions of engineer in charge of work.

701.358

-

131855.3

... More
KSRB15-3.3 : Providing 12mm thick cement plaster in single coat with cement mortar 1:6, to brick masonry including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. ---- as per directions of engineer in charge of work.

706.7895

-

137117.16

... More
KSRB15-3.3 : Providing 12mm thick cement plaster in single coat with cement mortar 1:6, to brick masonry including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. ---- as per directions of engineer in charge of work.

271.335

-

54267

... More
KSRB15-3.14 : Providing 12mm thick cement plaster in single coat with cement mortar 1:4, to ceiling including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. ---- as per directions of engineer in charge of work.

228.119

-

50186.18

... More
KSRB15-3.14 : Providing 12mm thick cement plaster in single coat with cement mortar 1:4, to ceiling including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. ---- as per directions of engineer in charge of work.

184.4772

-

41691.85

... More
KSRB15-3.14 : Providing 12mm thick cement plaster in single coat with cement mortar 1:4, to ceiling including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. ---- as per directions of engineer in charge of work.

93.9799

-

21803.34

... More
KSRB15-5.1 : Providing rough cement plastering 15mm thick in single coat with cement mortar 1:4, to brick masonry for base of dadooing works with sand of approved quality, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. ---- as per directions of engineer in charge of work.

93.975

-

18701.02

... More
KSRB15-5.1 : Providing rough cement plastering 15mm thick in single coat with cement mortar 1:4, to brick masonry for base of dadooing works with sand of approved quality, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. ---- as per directions of engineer in charge of work.

95.865

-

19652.32

... More
KSRB15-5.1 : Providing rough cement plastering 15mm thick in single coat with cement mortar 1:4, to brick masonry for base of dadooing works with sand of approved quality, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. ---- as per directions of engineer in charge of work.

113.712

-

23993.23

... More
Providing and laying flooring for corridors/lobbies using combination of pre polished 19 mm thick water cut/gang saw Grey Granite, Black Granite, and strips of 50mm wide pre flamed grey granite using pre polished grey granite 19mm thick 76%, Pre polished black granite 19mm thick @ 2% and preflamed 19mm thick grey granite @22% over existing cement concrete bed in CM 1:4 average 20mm thick pointed with white cement/colour pigment etc., complete. - using 19mm thick granite width not less than 1200mm ---- as per directions of engineer in charge of work.

133.5088

-

344719.72

... More
Providing and laying flooring for corridors/lobbies using combination of pre polished 19 mm thick water cut/gang saw Grey Granite, Black Granite, and strips of 50mm wide pre flamed grey granite using pre polished grey granite 19mm thick 76%, Pre polished black granite 19mm thick @ 2% and preflamed 19mm thick grey granite @22% over existing cement concrete bed in CM 1:4 average 20mm thick pointed with white cement/colour pigment etc., complete. - using 19mm thick granite width not less than 1200mm ---- as per directions of engineer in charge of work.

51.4435

-

132930

... More
Providing and fixing Special make glazed Vitrified tiles (Granomite finish) of approved make, quality and colour of size 600x600x10mm thick fixed on existing flooring with a special roffe adhesive for flooring and skirting etc., complete including providing spears at required interval and removing stains etc., complete. ---- as per directions of engineer in charge of work.

136.572

-

150092.63

... More
Providing and fixing Special make glazed Vitrified tiles (Granomite finish) of approved make, quality and colour of size 600x600x10mm thick fixed on existing flooring with a special roffe adhesive for flooring and skirting etc., complete including providing spears at required interval and removing stains etc., complete. ---- as per directions of engineer in charge of work.

43.731

-

48235.29

... More
Providing and fixing Special make glazed Vitrified tiles (Granomite finish) of approved make, quality and colour of size 600x600x10mm thick fixed on existing flooring with a special roffe adhesive for flooring and skirting etc., complete including providing spears at required interval and removing stains etc., complete. ---- as per directions of engineer in charge of work.

146.475

-

161268.98

... More
KSRB 14.14-5: Providing Ceramic tiles of approved make,shade and size for flooring, treads of steps and landings laid on a bed of 12mm thick, cement mortar 1:3 mix, flush pointing with white cement using colour pigment , including cost of materials, labour, curing, complete as per specifications. - for Ceramic Tiles of size 30x30cms 6mm thick ---- as per directions of engineer in charge of work.

24.7977

-

29881.23

... More
KSRB 14.14-5: Providing Ceramic tiles of approved make,shade and size for flooring, treads of steps and landings laid on a bed of 12mm thick, cement mortar 1:3 mix, flush pointing with white cement using colour pigment , including cost of materials, labour, curing, complete as per specifications. - for Ceramic Tiles of size 30x30cms 6mm thick ---- as per directions of engineer in charge of work.

23.4027

-

28247.06

... More
KSRB 14.14-5: Providing Ceramic tiles of approved make,shade and size for flooring, treads of steps and landings laid on a bed of 12mm thick, cement mortar 1:3 mix, flush pointing with white cement using colour pigment , including cost of materials, labour, curing, complete as per specifications. - for Ceramic Tiles of size 30x30cms 6mm thick ---- as per directions of engineer in charge of work.

27.7159

-

33508.52

... More
KSRB 14-17.2 : Providing skirting, dado, rises of steps with colour glazed tiles on 10mm thick cement plaster 1:3 and jointed with white cement slurry over rough plaster surface ( excluding cost of rough plastered surface which should be measured and paid separately) using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. Specification No.KBS 14.16, 14.17 - Colour glazed tiles 15x15 cms 6mm thick ---- as per directions of engineer in charge of work.

93.975

-

118972.35

... More
KSRB 14-17.2 : Providing skirting, dado, rises of steps with colour glazed tiles on 10mm thick cement plaster 1:3 and jointed with white cement slurry over rough plaster surface ( excluding cost of rough plastered surface which should be measured and paid separately) using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. Specification No.KBS 14.16, 14.17 - Colour glazed tiles 15x15 cms 6mm thick ---- as per directions of engineer in charge of work.

95.865

-

121556.82

... More
KSRB 14-17.2 : Providing skirting, dado, rises of steps with colour glazed tiles on 10mm thick cement plaster 1:3 and jointed with white cement slurry over rough plaster surface ( excluding cost of rough plastered surface which should be measured and paid separately) using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. Specification No.KBS 14.16, 14.17 - Colour glazed tiles 15x15 cms 6mm thick ---- as per directions of engineer in charge of work.

113.712

-

144414.24

... More
KSRB 7.9 : Providing and fixing M.S.grill work for windows and ventilators weighing 21kg/sqm using M.S. flats, or M.S. square rods, or combination of M.S. flats and square rods as per approved design, drawing including cutting steel sections and welding the same to required pattern with a coat of red lead primer, cost of materials, fixtures, labour and HOM of machinery complete as per specifications. Specification No. KBS 7.12 ---- as per directions of engineer in charge of work.

7261.075

-

689802.12

... More
Providing and fixing Stainless steel staircase raling as per Chief Architect Drawing No. 11520/ HRSC with hand rail 50mm dia 16 guage hollow pipe welded to vertical hollow 50mm dia pipe of 16 guage, stainless steel vertical pipe spaced at 1.20m regular intervals, and 5 Nos of 25mm dia. Stainless steel hollow horizontal pipe are welded to vertical 50mm dia hollow pipe. The entire assembly is fixed to staircase concrete by using expansion bolts by drilling concrete etc., complete including cost of materials, labour, HOM of machineries and electrical charges, etc., complete as per specifications. ---- as per directions of engineer in charge of work.

57.12

-

343919.52

... More
KSRB 7.1 : Providing and fixing in position collapsible steel shutters with single or double leaf with vertical channel 20mmx10mmx2mm braced with flat iron diagonals 20mmx5mm size, with top and bottom rails of T iron sections of 40x40x6 mm with 38mm dia steel pulleys complete with bolt and nuts, locking arrangements, stoppers, handles on both sides with 7.5cms openings at 10 cms. c to c applying a priming coat of red lead paint. cost of materials, labour, HOM of machinery complete as per specifications. size of gate 2.4mx1.4m. Specification No. KBS 7.7 / 7.12 ---- as per directions of engineer in charge of work.

11.376

-

59268.96

... More
KSRB 9.4-4 : Providing WHITE Sal wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves ( excluding cost of cement concrete and side clamps ), but including cost of materials, labour, HOM of machineries complete as per specifications. Specification No. KBS 9.33 ---- as per directions of engineer in charge of work.

0.5716

-

32792.12

... More
KSRB 9.4-4 : Providing WHITE Sal wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves ( excluding cost of cement concrete and side clamps ), but including cost of materials, labour, HOM of machineries complete as per specifications. Specification No. KBS 9.33 ---- as per directions of engineer in charge of work.

0.5551

-

31845.53

... More
KSRB 9.4-4 : Providing WHITE Sal wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves ( excluding cost of cement concrete and side clamps ), but including cost of materials, labour, HOM of machineries complete as per specifications. Specification No. KBS 9.33 ---- as per directions of engineer in charge of work.

0.5111

-

29321.3

... More
KSRB 9-27.1 : Fixing of door frame in an existing opening including embeeding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debries with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- as per directions of engineer in charge of work.

12

-

16392

... More
KSRB 9-27.1 : Fixing of door frame in an existing opening including embeeding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debries with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- as per directions of engineer in charge of work.

12

-

16392

... More
KSRB 9-27.1 : Fixing of door frame in an existing opening including embeeding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debries with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- as per directions of engineer in charge of work.

11

-

15026

... More
Providing and fixing flush door shutter made out of solid core black board type, well seasoned chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame all-round door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specification 2202 (Part-I) 1991. From manufacturer (Factory) complete as per specification. - 35mm thick both side teak ---- as per directions of engineer in charge of work.

11.9925

-

47298.42

... More
Providing and fixing flush door shutter made out of solid core black board type, well seasoned chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame all-round door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specification 2202 (Part-I) 1991. From manufacturer (Factory) complete as per specification. - 35mm thick both side teak ---- as per directions of engineer in charge of work.

11.9925

-

47298.42

... More
Providing and fixing flush door shutter made out of solid core black board type, well seasoned chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame all-round door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specification 2202 (Part-I) 1991. From manufacturer (Factory) complete as per specification. - 35mm thick both side teak ---- as per directions of engineer in charge of work.

6.15

-

24255.6

... More
Providing and fixing flush door shutter made out of solid core black board type, well seasoned chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame all-round door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specification 2202 (Part-I) 1991. From manufacturer (Factory) complete as per specification. - 30mm thick both side teak ---- as per directions of engineer in charge of work.

7.175

-

26561.85

... More
Providing and fixing flush door shutter made out of solid core black board type, well seasoned chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame all-round door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specification 2202 (Part-I) 1991. From manufacturer (Factory) complete as per specification. - 30mm thick both side teak ---- as per directions of engineer in charge of work.

7.175

-

26561.85

... More
Providing and fixing flush door shutter made out of solid core black board type, well seasoned chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame all-round door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specification 2202 (Part-I) 1991. From manufacturer (Factory) complete as per specification. - 30mm thick both side teak ---- as per directions of engineer in charge of work.

11.7875

-

43637.32

... More
uPvC Windows and Doors - Providing & fixing of Top hung Ventilator With Exhaust Fan Provision made out of multi chambered uPVC sections with TPV gaskets having isolated drainage and reinforced with Galvanized Iron profiles through out the Windown. the outer frame having a overall size of 60x55 mm with reinforcement of 1 mm thickness, Mullion with overall size of 74x60 mm with reinforcement of 1 mm thickness and Sash with overall size of 75x60 mm with reinforcement of 1.5mm thickness. Glazing bead for fixing of glass shall be of size 34x20 mml coextruded with gasket, Ventilator shall be provided with 4.5 mm Pin Head glass, standard hardware, single point locking and friction stays,. Wall thickness of frame, mullion & sash shall be 2-2.2 mm. ---- as per directions of engineer in charge of work.

29.07

-

151745.4

... More
uPvC Windows and Doors - Providing & fixing of Top hung Ventilator With Exhaust Fan Provision made out of multi chambered uPVC sections with TPV gaskets having isolated drainage and reinforced with Galvanized Iron profiles through out the Windown. the outer frame having a overall size of 60x55 mm with reinforcement of 1 mm thickness, Mullion with overall size of 74x60 mm with reinforcement of 1 mm thickness and Sash with overall size of 75x60 mm with reinforcement of 1.5mm thickness. Glazing bead for fixing of glass shall be of size 34x20 mml coextruded with gasket, Ventilator shall be provided with 4.5 mm Pin Head glass, standard hardware, single point locking and friction stays,. Wall thickness of frame, mullion & sash shall be 2-2.2 mm. ---- as per directions of engineer in charge of work.

28.89

-

150805.8

... More
uPvC Windows and Doors - Providing & fixing of Top hung Ventilator With Exhaust Fan Provision made out of multi chambered uPVC sections with TPV gaskets having isolated drainage and reinforced with Galvanized Iron profiles through out the Windown. the outer frame having a overall size of 60x55 mm with reinforcement of 1 mm thickness, Mullion with overall size of 74x60 mm with reinforcement of 1 mm thickness and Sash with overall size of 75x60 mm with reinforcement of 1.5mm thickness. Glazing bead for fixing of glass shall be of size 34x20 mml coextruded with gasket, Ventilator shall be provided with 4.5 mm Pin Head glass, standard hardware, single point locking and friction stays,. Wall thickness of frame, mullion & sash shall be 2-2.2 mm. ---- as per directions of engineer in charge of work.

13.77

-

71879.4

... More
Providing, fabricating and fixing of stick type structural glazing using Alluminium Extrusions of 63.5 mm x 58.00 mmx 2.25 mm of 1.73 kgs/ mtr for vertical and Horizontal members and 63.5 mm x 38.1 x 1.33 mm of 0.759 kg/Mtr, as outer frame with Electro Anodized Paint coated block finishing, using 6mm thick imported glass reflective hard coatedocean blue raw glass with all necessary accesories like ultra glass Silicon sealant of Space tape, Masking tape, Galvanized Anchaor bolt, machine screws, 6mm thick M.S. angle 50mm x 150mm x 6mm M.S. Galvanized L Brackets, structural sealent setting clocks, fasteners, wall connection etc., complete. ---- as per directions of engineer in charge of work.

58.981

-

392400.59

... More
Providing and finishing external walls in two coats over one coat of primer with antifungal paint of approved brand and shade to give an even shade after thoroughly brooming the surface to remove all dirt and loose powdered material, free from mortar drops and other foreign matter cost of materials, labour, complete as per specifications. ---- as per directions of engineer in charge of work.

417.172

-

75090.96

... More
Providing and finishing external walls in two coats over one coat of primer with antifungal paint of approved brand and shade to give an even shade after thoroughly brooming the surface to remove all dirt and loose powdered material, free from mortar drops and other foreign matter cost of materials, labour, complete as per specifications. ---- as per directions of engineer in charge of work.

273.424

-

50310.02

... More
Providing and finishing external walls in two coats over one coat of primer with antifungal paint of approved brand and shade to give an even shade after thoroughly brooming the surface to remove all dirt and loose powdered material, free from mortar drops and other foreign matter cost of materials, labour, complete as per specifications. ---- as per directions of engineer in charge of work.

324.68

-

61039.84

... More
Providing applying two coats of wall putty to inside plastered walls and ceiling using white cement putty. Scrapping and levelling the surface using steel blade and preparing the surface even and smooth by using different grade sand papers, including cost of all materials, cost of labour and scaffolding etc., complete as per the specification. Area to be considered - (a) 100% for fresh surface (b) Upto 10% for repainting ---- as per directions of engineer in charge of work.

929.476

-

72499.13

... More
Providing applying two coats of wall putty to inside plastered walls and ceiling using white cement putty. Scrapping and levelling the surface using steel blade and preparing the surface even and smooth by using different grade sand papers, including cost of all materials, cost of labour and scaffolding etc., complete as per the specification. Area to be considered - (a) 100% for fresh surface (b) Upto 10% for repainting ---- as per directions of engineer in charge of work.

891.266

-

69518.75

... More
Providing applying two coats of wall putty to inside plastered walls and ceiling using white cement putty. Scrapping and levelling the surface using steel blade and preparing the surface even and smooth by using different grade sand papers, including cost of all materials, cost of labour and scaffolding etc., complete as per the specification. Area to be considered - (a) 100% for fresh surface (b) Upto 10% for repainting ---- as per directions of engineer in charge of work.

365.315

-

28494.57

... More
KSRB 15-15.1 : Providing and applying painting in two coats with plastic emulsion paint of approved brand on wall surface to give an even approved shade after thoroughly brushing the surface, free from mortar drops and other foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour, complete as per specifications. - with primer ---- as per directions of engineer in charge of work.

929.476

-

83652.84

... More
KSRB 15-15.1 : Providing and applying painting in two coats with plastic emulsion paint of approved brand on wall surface to give an even approved shade after thoroughly brushing the surface, free from mortar drops and other foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour, complete as per specifications. - with primer ---- as per directions of engineer in charge of work.

891.267

-

80214.03

... More
KSRB 15-15.1 : Providing and applying painting in two coats with plastic emulsion paint of approved brand on wall surface to give an even approved shade after thoroughly brushing the surface, free from mortar drops and other foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour, complete as per specifications. - with primer ---- as per directions of engineer in charge of work.

365.315

-

32878.35

... More
Providing RCC design mix M20 using granite metal 20mm and down size for 7.5 cms thick solid parapet or perforated as per design, specification and directions.(exclusive of cost of steel and fabrication charges) including necessary centring, form work and finishing smooth with CM (1:3) etc., complete. - 10cms thick ---- as per directions of engineer in charge of work.

4.8

-

3052.8

... More
Providing RCC design mix M20 using granite metal 20mm and down size for 7.5 cms thick solid parapet or perforated as per design, specification and directions.(exclusive of cost of steel and fabrication charges) including necessary centring, form work and finishing smooth with CM (1:3) etc., complete. - 10cms thick ---- as per directions of engineer in charge of work.

4.8

-

3052.8

... More
KSRB 4-6.13 :Providing and removing, centering, shuttering, strutting, propping etc., and removal of form work for vertical fins and vertical sun breakers including cost of all materials, labour complete as per specifications. Specification No. KBS 4.6.2 ---- as per directions of engineer in charge of work.

9.6

-

5760

... More
KSRB 4-6.13 :Providing and removing, centering, shuttering, strutting, propping etc., and removal of form work for vertical fins and vertical sun breakers including cost of all materials, labour complete as per specifications. Specification No. KBS 4.6.2 ---- as per directions of engineer in charge of work.

9.6

-

5760

... More
KSRB 4.9.2 : Providing T.M.T steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid) cost of materials, labour, HOM of machinery complete as per specifications. Specification No. KBS 4.6.3 - TMT bars Fe 500 ---- as per directions of engineer in charge of work.

12.4191

-

886984.54

... More
KSRB 4.9.2 : Providing T.M.T steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid) cost of materials, labour, HOM of machinery complete as per specifications. Specification No. KBS 4.6.3 - TMT bars Fe 500 ---- as per directions of engineer in charge of work.

6.4776

-

462636.67

... More
Lift charges for steel of all diameters for additional floors over ground floor per floor height of 3.5 m. or part thereof cost of labour, complete as per specifications. ---- as per directions of engineer in charge of work.

6.4776

-

4845.24

... More
KSRB 4.9.2 : Providing T.M.T steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid) cost of materials, labour, HOM of machinery complete as per specifications. Specification No. KBS 4.6.3 - TMT bars Fe 500 ---- as per directions of engineer in charge of work.

3.4883

-

249137.87

... More
Lift charges for steel of all diameters for additional floors over ground floor per floor height of 3.5 m. or part thereof cost of labour, complete as per specifications. ---- as per directions of engineer in charge of work.

3.4883

-

2609.25

... More
Providing wall black boards in CM 1:3 with two coats of black paint including finishing etc., including cost of materials, labour, HOM complete as per specifications. ---- as per directions of engineer in charge of work.

40.5

-

29767.5

... More
KSRB 15-17.6 : Providing and applying painting two coats ( excluding priming coat ) on new wood surface and / or wood based surface with enamel paint to give an even shade, cleaning the surface of all dirt, dust and foreign matter, sand papering including cost of materials, labour, complete as per specifications. ---- as per directions of engineer in charge of work.

96.6356

-

9373.65

... More
KSRB 15-17.6 : Providing and applying painting two coats ( excluding priming coat ) on new wood surface and / or wood based surface with enamel paint to give an even shade, cleaning the surface of all dirt, dust and foreign matter, sand papering including cost of materials, labour, complete as per specifications. ---- as per directions of engineer in charge of work.

68.6

-

6654.2

... More
KSRB 15-17.6 : Providing and applying painting two coats ( excluding priming coat ) on new wood surface and / or wood based surface with enamel paint to give an even shade, cleaning the surface of all dirt, dust and foreign matter, sand papering including cost of materials, labour, complete as per specifications. ---- as per directions of engineer in charge of work.

22.4475

-

2177.41

... More
KSRRB M800-10. Painting new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade complete as per specifications. (“ii) English and Roman - Hyphen and the like not to be measured and paid for “ MORTH Specification No.801 ---- as per directions of engineer in charge of work.

3000

-

2100

... More
KSRB13-1.6 : Providing and fixing to wall, ceiling and floor galvanised / mild steel tube 50mm dia nominal bore with fittings (medium grade weight 5.24kg/mtr) B class including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. Specification No.KBS 13.2.14 / 13.8 ---- as per directions of engineer in charge of work.

8

-

4096

... More
KSRB 15.8.2 Providing and fixing plaster mesh 150mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment ) ---- as per directions of engineer in charge of work.

1000

-

31000

... More
Earth work excavation for foundation of structures by mechanical means as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising / transporting the remaining earth locally upto 1.00km lead. (Depth upto 3.00 Mts) -In all types of soil ---- as per directions of engineer in charge of work.

108

-

5616

... More
KSRB 2-4 : Refilling available earth around pipe lines, cables in layers not exceeding 20cms in depth, compacting each deposited layer by ramming after watering with lead upto 50m. and lift upto 1.5 m. including cost of all labour complete as per specifications. ---- as per directions of engineer in charge of work.

108

-

13068

... More
Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete. (Concealed work including cutting chases and good the walls etc.) - 20mm nominal OD pipes ---- as per directions of engineer in charge of work.

50

-

11750

... More
Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work). - 40mm nominal OD pipes ---- as per directions of engineer in charge of work.

100

-

29200

... More
Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work). - 32mm nominal OD pipes ---- as per directions of engineer in charge of work.

50

-

11300

... More
Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work). - 50mm nominal OD pipes ---- as per directions of engineer in charge of work.

5

-

2160

... More
KSRB13-8.7 : Providing and fixing to wall, ceiling and floor, low density polyethylene pipes 6.00 kgf/sq.cm working pressure 75mm outside diameter with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. Specification No.KBS 13.2.15.1 / 13.9 ---- as per directions of engineer in charge of work.

40

-

13040

... More
KSRB13-8.9 : Providing and fixing to wall, ceiling and floor, low density polyethylene pipes 6.00 kgf/sq.cm working pressure 110mm outside diameter with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. Specification No.KBS 13.2.15.1 / 13.9 ---- as per directions of engineer in charge of work.

239

-

107550

... More
KSRB13-8.9 : Providing and fixing to wall, ceiling and floor, low density polyethylene pipes 6.00 kgf/sq.cm working pressure 160mm outside diameter with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. Specification No.KBS 13.2.15.1 / 13.9 ---- as per directions of engineer in charge of work.

100

-

62700

... More
KSRB 13-11.1 : Providing and placing on terrace, polyethylene water storage tanks with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials, labour, transport charges, HOM of equipments and testing complete as per specifications.(For 1000 litre capacity) Specification No.KBS 13.22 ---- as per directions of engineer in charge of work.

2

-

13656

... More
Constructing brick masonry inspection chamber 600x600mm, and 450mm depth, ( clear inside dimension ) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover withframe (light duty) 455x610mm internal dimensions, total weight of cover with frame to be not less than 38 kg ( weight of cover 23kg and weight of frame 15 kg) R.C.C. top slab with cement concrete M 15 with 20mm and downsize granite metal, foundation concrete M 5 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 600x600mm and 450mm depth ( clear inside dimension ) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover withframe (light duty) 600x600mm ---- as per directions of engineer in charge of work.

8

-

67920

... More
Constructing brick masonry inspection chamber 450x450mm, and 450mm depth, ( clear inside dimension ) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover withframe (light duty) 455x610mm internal dimensions, total weight of cover with frame to be not less than 38 kg ( weight of cover 23kg and weight of frame 15 kg) R.C.C. top slab with cement concrete M 15 with 20mm and downsize granite metal, foundation concrete M 5 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 450x450mm and 450mm depth ( clear inside dimension ) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover withframe (light duty) 450x450mm ---- as per directions of engineer in charge of work.

8

-

42400

... More
KSRB13-6.3-4 : Providing and fixing in position brass gate valve with C.I wheel of approved quality ( screwed end ) 32mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. Specification No.KBS 13.2.6 / 13.3 ---- as per directions of engineer in charge of work.

3

-

2490

... More
KSRB13-6.3-5 : Providing and fixing in position brass gate valve with C.I wheel of approved quality ( screwed end ) 40mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. Specification No.KBS 13.2.6 / 13.3 ---- as per directions of engineer in charge of work.

3

-

3120

... More
Providing and fixing white vitreous china clay urinals with flat back of approved make fixed to wooden plugs including bends, painting white to exposed pipes etc., complete as per directions.(rate includes cost of all materials and lead).A grade. ---- as per directions of engineer in charge of work.

8

-

6800

... More
KSRB 11-2 : Providing and fixing white vitreous china clay, water closet Orissa pattern of size 580 x 440mm with integral type footrests, 100mm S or P trap, 10 litre low level, P.V.C flushing cistern ( all are approved make ) with fittings, C.I / M.S brackets, 32mm diameter flush pipe fittings and clamps, overflow arrangements with special and 25mm mosquito proof coupling of approved design, painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specifications. Specification No. KBS 11 ---- as per directions of engineer in charge of work.

6

-

25344

... More
KSRB 11-5 : Providing and fixing white vitreous china clay, water closet European type ( Pedestal type, P-trap ) with black solid plastic seat and lid, C.P brass hinges, rubber buffers. 10 litre low level, P.V.C flushing cistern ( all are approved make ) with fittings, C.I / M.S brackets, 40mm diameter flush bend with fittings and clamps, overflow arrangements with special and 25mm mosquito proof coupling of approved design, painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specifications. Specification No. KBS 11 ---- as per directions of engineer in charge of work.

9

-

44604

... More
KSRB 11-11.1 : Providing and fixing white vitreous china clay, flat back wash basin size 630x450mm with a pair of 15mm C.P brass pillar taps with C.I / M.S brackets, 32 mm C.P. brass waste of standard pattern, painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specifications. Specification No. KBS 11 ---- as per directions of engineer in charge of work.

11

-

44077

... More
KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded non-modular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4 ---- as per directions of engineer in charge of work.

3

-

43749

... More
KSRB 11-15.1 : Providing and fixing 600x450mm bevelLead edge mirror of superior glass with 6mm hard board backing and fixed to wooden cleats with C.P screws, washers, including cost of materials, labour complete as per specifications. ---- as per directions of engineer in charge of work.

11

-

12727

... More
KSRB 11-17-1 : Providing and fixing C.P. brass towel rail 740mm length, 20mm dia with C.P brackets, fixed to wooden cleats with C.P. brass screws including cost of materials, labour complete as per specifications. ---- as per directions of engineer in charge of work.

11

-

8129

... More
Providing and fixing 7.5 cms to 15.00 cms dia NP grating 100 mm dia. ---- as per directions of engineer in charge of work.

15

-

2250

... More
Providing and fixing CI Nahani trap of approved make conforming to ISI specifications and construction of Cistern in M-15 as per directions (Rate is inclusive of cost of materials and fixtures and conveyance of materials to work spot). - 12.5cms x 7.5cms ---- as per directions of engineer in charge of work.

15

-

4275

... More
Providing NP/CP waste unions conforming to ISI specifications and fixing them in position as per directions including cost of materials, fixtures and conveyance to work spot etc., complete. - for 32mm dia ---- as per directions of engineer in charge of work.

15

-

1800

... More
Wall bores in size stone masonry. including cost of materials, labour, HOM complete as per specifications.- - upto 45 cm thick. ---- as per directions of engineer in charge of work.

10

-

3030

... More
Wall bores in Brick masonry upto 45 em thick. including cost of materials, labour, HOM complete as per specifications. ---- as per directions of engineer in charge of work.

30

-

3780

... More
Earth work excavation for foundation of structures by mechanical means as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising / transporting the remaining earth locally upto 1.00km lead. (Depth upto 3.00 Mts) -In all types of soil ---- as per directions of engineer in charge of work.

8.3915

-

436.36

... More
Earth work excavation for foundation of structures by mechanical means as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising / transporting the remaining earth locally upto 1.00km lead. (Depth upto 3.00 Mts) -In all types of soil ---- as per directions of engineer in charge of work.

2.1

-

109.2

... More
KSRB 4-1.3 : Providing and laying in position plain cement concrete of mix 1:4:8 with OPC cement @ 180kgs, with 40mm and down size graded granite metal coarse aggregates @0.85cum and fine aggregates @ 0.57cum machine mixed, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, including cost of all materials, labour, HOM of machinery, curing complete as per specifications. Specification No. KBS 4.1, 4.2 ---- as per directions of engineer in charge of work.

0.8505

-

4267.81

... More
KSRB15-3.11 : Providing 20mm thick cement plaster in single coat with cement mortar 1:4, to stone masonry & concrete surface including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. ---- as per directions of engineer in charge of work.

13.26

-

3474.12

... More
KSRB15-4.1 Extra for providing and mixing waterproofing compound in cement plaster work at one kg per bag or in the proportion recommended by the manufacturers, for cement mortar 1:3, 12mm thick cost of materials complete as per specifications. ---- as per directions of engineer in charge of work.

13.26

-

92.82

... More
KSRB15-3.14 : Providing 12mm thick cement plaster in single coat with cement mortar 1:4, to ceiling including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. ---- as per directions of engineer in charge of work.

7.2

-

1584

... More
KSRB15-4.1 Extra for providing and mixing waterproofing compound in cement plaster work at one kg per bag or in the proportion recommended by the manufacturers, for cement mortar 1:3, 12mm thick cost of materials complete as per specifications. ---- as per directions of engineer in charge of work.

7.2

-

50.4

... More
KSRB 4.9.2 : Providing T.M.T steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid) cost of materials, labour, HOM of machinery complete as per specifications. Specification No. KBS 4.6.3 - TMT bars Fe 500 ---- as per directions of engineer in charge of work.

0.5645

-

40317.15

... More
Earth work excavation for foundation of structures by mechanical means as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising / transporting the remaining earth locally upto 1.00km lead. (Depth upto 3.00 Mts) -In all types of soil ---- as per directions of engineer in charge of work.

20.3575

-

1058.59

... More
Earth work excavation for foundation of structures by mechanical means as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising / transporting the remaining earth locally upto 1.00km lead. (Depth upto 3.00 Mts) -In all types of soil ---- as per directions of engineer in charge of work.

5.09

-

264.68

... More
KSRB 4-1.3 : Providing and laying in position plain cement concrete of mix 1:4:8 with OPC cement @ 180kgs, with 40mm and down size graded granite metal coarse aggregates @0.85cum and fine aggregates @ 0.57cum machine mixed, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, including cost of all materials, labour, HOM of machinery, curing complete as per specifications. Specification No. KBS 4.1, 4.2 ---- as per directions of engineer in charge of work.

1.6965

-

8513.04

... More
KSRB 5.4-4 : Providing and constructing granite / trap / basalt size stone masonry in superstructure with cement mortar 1:4 , edges of stones chistle dressed in courses not less than 15 cms high, bond stones at two m. apart in each course including cost of materials, labour, scaffolding, curing complete as per specifications. KBS 5.1.13 ---- as per directions of engineer in charge of work.

14.514

-

92062.3

... More
KSRB 4.2.8: Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in ground floor level for roof slabs, staircase, lintles, and beams retaining walls, return walls, walls (any thickness) including attached plasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 ---- as per directions of engineer in charge of work.

2.8275

-

16591.77

... More
KSRB 4-6.3 : Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for flat surface such as suspended floors, roofs, landings, balconies and likes, thickness above 200 mm including cost of all materials, labour complete as per Specification. Specification No. KBS 4.6.2 ---- as per directions of engineer in charge of work.

13.35

-

5967.45

... More
KSRB15-3.11 : Providing 20mm thick cement plaster in single coat with cement mortar 1:4, to stone masonry & concrete surface including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. ---- as per directions of engineer in charge of work.

36.16

-

9473.92

... More
KSRB15-4.1 Extra for providing and mixing waterproofing compound in cement plaster work at one kg per bag or in the proportion recommended by the manufacturers, for cement mortar 1:3, 12mm thick cost of materials complete as per specifications. ---- as per directions of engineer in charge of work.

36.16

-

253.12

... More
KSRB15-3.14 : Providing 12mm thick cement plaster in single coat with cement mortar 1:4, to ceiling including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. ---- as per directions of engineer in charge of work.

6

-

1320

... More
KSRB15-4.1 Extra for providing and mixing waterproofing compound in cement plaster work at one kg per bag or in the proportion recommended by the manufacturers, for cement mortar 1:3, 12mm thick cost of materials complete as per specifications. ---- as per directions of engineer in charge of work.

6

-

42

... More
KSRB 4.9.2 : Providing T.M.T steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid) cost of materials, labour, HOM of machinery complete as per specifications. Specification No. KBS 4.6.3 - TMT bars Fe 500 ---- as per directions of engineer in charge of work.

0.2827

-

20190.72

... More
KSRB 2.3 : Filling available excavated earth ( excluding rock ) in sides of foundations upto plinth in layers not exceeding 20 cms. in depth, compacting each deposited layer by ramming after watering with lead upto 50 m. and lift upto 1.5 m. including cost of all labour complete as per specifications. specification. No. KBS 2.9 ---- as per directions of engineer in charge of work.

5.09

-

1023.09

... More
KSRB 2.5 : Earthwork excavation in all soil deposits and filling sides of foundation upto plinth in layers not exceeding 20cms. in depth, compacting each deposited layer by ramming after watering with all lead and lift including cost of all labour complete as per specifications. specification. No. KBS 2.9.9 / 2.9.10.1 / 2.1.1 ---- as per directions of engineer in charge of work.

15.834

-

6381.1

... More
Earth work excavation for foundation of structures by mechanical means as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising / transporting the remaining earth locally upto 1.00km lead. (Depth upto 3.00 Mts) -In all types of soil ---- as per directions of engineer in charge of work.

16.8085

-

874.04

... More
Earth work excavation for foundation of structures by mechanical means as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising / transporting the remaining earth locally upto 1.00km lead. (Depth upto 3.00 Mts) -In all types of soil ---- as per directions of engineer in charge of work.

4.2

-

218.4

... More
KSRB 2.8 : Providing and Filling in foundation with granite / trap broken metal 100mm. and down size, with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift. complete as per specifications. specification. No. KBS ---- as per directions of engineer in charge of work.

12.5534

-

24290.83

... More
KSRB 2.6 : Providing and filling sand in foundation upto plinth to required depth for sub soil treatment including watering ramming with all lead and lift complete as per specifications.specification. No. KBS 2.10.2 ---- as per directions of engineer in charge of work.

4.239

-

7503.03

... More
KSRB 5-1.1 : Providing and constructing granite / trap / basalt rubble stone masonry in foundation with mud mortar (uncoursed), bond stones at two m. apart in each course including cost of materials, labour, curing complete as per specifications. KBS 5.1.12 ---- as per directions of engineer in charge of work.

3.375

-

7830

... More
KSRB13-8.8 : Providing and fixing to wall, ceiling and floor, low density polyethylene pipes 6.00 kgf/sq.cm working pressure 90mm outside diameter with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. Specification No.KBS 13.2.15.1 / 13.9 ---- as per directions of engineer in charge of work.

25

-

9500

... More
KSRB 2-4 : Refilling available earth around pipe lines, cables in layers not exceeding 20cms in depth, compacting each deposited layer by ramming after watering with lead upto 50m. and lift upto 1.5 m. including cost of all labour complete as per specifications. ---- as per directions of engineer in charge of work.

21.01

-

2542.21

... More
Earth work excavation for foundation of structures by mechanical means as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising / transporting the remaining earth locally upto 1.00km lead. (Depth upto 3.00 Mts) -In all types of soil ---- as per directions of engineer in charge of work.

161.2

-

8382.4

... More
KSRB 4-1.3 : Providing and laying in position plain cement concrete of mix 1:4:8 with OPC cement @ 180kgs, with 40mm and down size graded granite metal coarse aggregates @0.85cum and fine aggregates @ 0.57cum machine mixed, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, including cost of all materials, labour, HOM of machinery, curing complete as per specifications. Specification No. KBS 4.1, 4.2 ---- as per directions of engineer in charge of work.

26.35

-

132224.3

... More
Providing and laying plain/reinforced cement concrete for side drains using M20 nominal mix concrete with OPC at 300 kgs. with 20mm and down size granite metal coarse aggregates at 0.69 cum and fine aggregates at 0.43 cum machine mixed, well compacted for walls and bottom including centering, shuttering, cost of materials, HOM of machinery, curing etc., complete excluding cost of steel as per MORTH specification No. 1500, 1700, 2200. including cost of materials, labour, HOM complete as per specifications. Wall & bottom thickness 10cm ---- as per directions of engineer in charge of work.

57.35

-

380173.15

... More
KSRB 4.9.2 : Providing T.M.T steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid) cost of materials, labour, HOM of machinery complete as per specifications. Specification No. KBS 4.6.3 - TMT bars Fe 500 ---- as per directions of engineer in charge of work.

2.8836

-

205949.6

... More
Providing and laying 1 OOmm thick pre-cast cover slabs over drains of width not exceeding 800 mm using M20 concrete reinforced with steel @ 6.00 kg/Sqm, slabs JOinted in CM 1:3 proportion and nicely finished including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, HOM, curing, lead and lift charges etc, Complete as per MORTH specifications No. 1500, 1700. ---- as per directions of engineer in charge of work.

310

-

340380

... More
KSRRB M300-59.2. Loosening, levelling and compacting origial ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. complete as per specifications. Case-II: Compacting original ground supporting embankment.(which includes watering charges & compaction by vibratory roller) MORTH Specification No. 305.3.4 ---- as per directions of engineer in charge of work.

1162.5

-

26737.5

... More
KSRRB M300- Construction of Embankment with Material Gravel/ Murrum. KSRRB M300-53. Construction of embankment with approved material Gravel/Murrum with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement Table 300- 2 complete as per specifications.(Including cost of gravel / murrum, watering charges & compaction by vibratory roller to 95% of proctors density) MORTH Specification No. 305 ---- as per directions of engineer in charge of work.

449.5

-

260260.5

... More
Construction of granular sub-base Grading-V as Sub-base and drainage layer by providing coarse graded crushed stone aggregates of granite/trap/basalt material, mixing by mix in place method by rotavator at OMC, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the 98 % proctor density, complete as per specifications. Clause 401 of MORTH V Revision. ---- as per directions of engineer in charge of work.

85.25

-

147226.75

... More
KSRRB M400- Water Bound Macadam KSRRB M400-14.1. Providing, laying, spreading andcompacting crushed stone aggregates of granite / trap / basalt specific sizes to water bound macadam specifications including spreading in uniform thickness, hand packing, rolling with 3- wheeled steel/vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/binding materials to fill up the interstices of coarse aggregates, watering and compacting to the required density complete as per Specification. A. By mannual means. MORTH Specification No. 404 - Type B 11.2mm for grading III ---- as per directions of engineer in charge of work.

63.9375

-

156902.62

... More
Constructing un-reinforced, plain cement concrete for pavements using Grade concrete M30 over a prepared base with OPC coarse aggregate at 0.69 cum, fine aggregates at 0.46 cum,Coarse and fine aggregate conforming to IS:383-2016, with Superplastizer at 3 Its conforming to IS 9103-2008. mixed in a concrete mixer of not less than 0.6 cum capacity and appropriate weigh batcher as per approved mix design, laid in approved fixed side form work (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the form work as per drawing). & Spreading the concrete with shovels, rackers compacted using needle, screed and plate vibrator and finished with floaters in a continuous operation including provision of contraction, expansion, construction and longitudinal joints,including groove cutting charges, joint filler, separation membrane of impermiable plastic sheet of 125 micron, sealant primer, joint sealant, admixtures as approved, curing compound, finishing to lines and grades, textured with texturing machine, and curing including cost of all materials, labour,hire charges of machineries,all lead & lift charges etc., complete as per specifications. with- with OPC at 320 kg/cum and GGBS 40 kg/cum conforming to IS:12089, coarse aggregate 0.69cum, fine aggregate 0.46cum. ---- as per directions of engineer in charge of work.

127.875

-

606511.12

... More
KSRB 14.6-2 :Providing and laying heavy duty cobble stones 75mm thick interlock pavers, using cement and course sand for manufacture of blocks of approved size, shape and colour with a minimum compressive strength of 281 kg per sqm over 50mm thick sand bed (average thickness ) and compacting with plate vibrator having 3 tons compaction force thereby forcing part of sand underneath to come up in between joints, final compaction of paver surface joints into its final level, including cost of materials, labour and HOM of machineries complete as per specifications. Specification No. KBS ---- as per directions of engineer in charge of work.

302.5

-

331237.5

... More
Providing and fixing Pre cast solid concrete kerb stones made out of CC 1:2:4 and finished with CM 1:3 plastering and finishing cutting etc., complete. - of size 450 x 200 x 400 mm ---- as per directions of engineer in charge of work.

270

-

121770

... More
Earth work excavation for foundation of structures by mechanical means as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising / transporting the remaining earth locally upto 1.00km lead. (Depth upto 3.00 Mts) -In all types of soil ---- as per directions of engineer in charge of work.

5.4

-

280.8

... More
Earth work excavation for foundation of structures by mechanical means as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising / transporting the remaining earth locally upto 1.00km lead. (Depth upto 3.00 Mts) -In all types of soil ---- as per directions of engineer in charge of work.

1.08

-

56.16

... More
KSRB 4-1.3 : Providing and laying in position plain cement concrete of mix 1:4:8 with OPC cement @ 180kgs, with 40mm and down size graded granite metal coarse aggregates @0.85cum and fine aggregates @ 0.57cum machine mixed, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, including cost of all materials, labour, HOM of machinery, curing complete as per specifications. Specification No. KBS 4.1, 4.2 ---- as per directions of engineer in charge of work.

0.675

-

3387.15

... More
KSRB 4.2.2 : Providing and laying in position reinforced cement concrete of Design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregtes @ 0.460 cum, with super plasticisers @ 3 liters confirming to is 9103-1999 reafirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in foundation for footings, pedastals, retaining walls, return walls, walls (any thickness) including attached pilasters, columnspillars, posts, struts, buttresses, bed blocks, anchor blocks & plinths etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 ---- as per directions of engineer in charge of work.

1.296

-

7302.96

... More
KSRB 4-6.1 : Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for foundations, footings, bases of columns for mass concrete including cost of all materials, labour complete as per specificaitons. Specification No. KBS 4.6.2 ---- as per directions of engineer in charge of work.

2.88

-

754.56

... More
KSRB 4.2.8: Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in ground floor level for roof slabs, staircase, lintles, and beams retaining walls, return walls, walls (any thickness) including attached plasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 ---- as per directions of engineer in charge of work.

0.2898

-

1700.55

... More
KSRB 4-6.5 : Providing and removing centering, shuttering, strutting, propping etc., for columns, pillars, post and struts, square / rectangular/ polygon in plan including cost of all materials, labour complete as per specifications. Specification No. KBS 4.6.2 ---- as per directions of engineer in charge of work.

8.056

-

3673.54

... More
KSRB 2.3 : Filling available excavated earth ( excluding rock ) in sides of foundations upto plinth in layers not exceeding 20 cms. in depth, compacting each deposited layer by ramming after watering with lead upto 50 m. and lift upto 1.5 m. including cost of all labour complete as per specifications. specification. No. KBS 2.9 ---- as per directions of engineer in charge of work.

1.08

-

217.08

... More
KSRB 2.5 : Earthwork excavation in all soil deposits and filling sides of foundation upto plinth in layers not exceeding 20cms. in depth, compacting each deposited layer by ramming after watering with all lead and lift including cost of all labour complete as per specifications. specification. No. KBS 2.9.9 / 2.9.10.1 / 2.1.1 ---- as per directions of engineer in charge of work.

8.02

-

3232.06

... More
KSRB 6-1.3 : Providing and constructing burnt brick masonry for basement and superstructure with approved quality of non-modular bricks of standard size of class designation 3.5Newton per sqmm with cement mortar1:6 including cost of materials, labour charges, scaffolding, curing complete as per specifications. Specification No. KBS 6.2 ---- as per directions of engineer in charge of work.

47.61

-

279518.31

... More
KSRB 4-1.7 : Providing and laying in position plain cement concrete of mix 1:3:6 with OPC cement @ 220kgs, with 20mm and down size graded granite metal coarse aggregates @0.84cum and fine aggregtes @ 0.56cum, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, plinth and cills, ncluding cost of all materials, labour, HOM of machinery, curing complete as per specifications. Specification No. KBS 4.1, 4.2 ---- as per directions of engineer in charge of work.

12.4718

-

66125.48

... More
KSRB15-3.9 :Providing 18mm thick cement plaster in single coat with cement mortar 1:6, to brick masonry including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. ---- as per directions of engineer in charge of work.

733.845

-

174655.11

... More
Providing and finishing external walls in two coats over one coat of primer with antifungal paint of approved brand and shade to give an even shade after thoroughly brooming the surface to remove all dirt and loose powdered material, free from mortar drops and other foreign matter cost of materials, labour, complete as per specifications. ---- as per directions of engineer in charge of work.

733.845

-

132092.1

... More
KSRB 7.9 : Providing and fixing M.S.grill work for windows and ventilators weighing 21kg/sqm using M.S. flats, or M.S. square rods, or combination of M.S. flats and square rods as per approved design, drawing including cutting steel sections and welding the same to required pattern with a coat of red lead primer, cost of materials, fixtures, labour and HOM of machinery complete as per specifications. Specification No. KBS 7.12 ---- as per directions of engineer in charge of work.

3034.125

-

288241.88

... More
KSRB 4.9.2 : Providing T.M.T steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid) cost of materials, labour, HOM of machinery complete as per specifications. Specification No. KBS 4.6.3 - TMT bars Fe 500 ---- as per directions of engineer in charge of work.

0.1068

-

7627.76

... More
CUBICLE WORKSTATIONS Providing and fixing CUBICLE WORKSTATIONS consisting of wings made out of 75 mm thick MS CRCA powder coated ,tile based system for main and return spine, Top tile finish 8 mm thick MDF covered with Fabric of approved colour and one writing board (600 mm w) and one soft board (600 mmw) per workstation, Bottom tile finish 9 mm thick Laminate tile of approved colour, Raceway- one middle raceway (600mmW) below table top per workstation and continous raceway at the skirting level, Wire manager- ABS plastic grommet one number per table,Table top - 25 mm thick PLPB with straight table top End Table 25 mm thick PLPB with straightedge bound Hardware-MS powder coated corner bkt, cantilever bkt, separator hook on bkt, L bkt and Table joint plate., as per specifications , drawings and as directed by Engineer in charge - C TYPE 2 wings 3D) Size : 1500 mmW x 1500mm D x 1200 mm ht: ---- as per directions of engineer in charge of work.

5

-

258000

... More
CUBICLE WORKSTATIONS Providing and fixing CUBICLE WORKSTATIONS consisting of wings made out of 75 mm thick MS CRCA powder coated ,tile based system for main and return spine, Top tile finish 8 mm thick MDF covered with Fabric of approved colour and one writing board (600 mm w) and one soft board (600 mmw) per workstation, Bottom tile finish 9 mm thick Laminate tile of approved colour, Raceway- one middle raceway (600mmW) below table top per workstation and continous raceway at the skirting level, Wire manager- ABS plastic grommet one number per table,Table top - 25 mm thick PLPB with straight table top End Table 25 mm thick PLPB with straightedge bound Hardware-MS powder coated corner bkt, cantilever bkt, separator hook on bkt, L bkt and Table joint plate., as per specifications , drawings and as directed by Engineer in charge - L TYPE one wing 3C) Size : 1500 mmW x 1200mm D x 1200 mm ht: ---- as per directions of engineer in charge of work.

5

-

105000

... More
Storage Unit - wooden - One side laminate Providing and fixing woode storage unit one side laminate with 18 mm PLY/PLPB with edge bound for body, 18mm PLY/PLPB with openable shutters and individual locking system for shutter, 9 mm PLY with edge bound for rear portion with Hafele fitting hinges, Hafele locks,Minifix assembly, screw legs, Handles and tower bolt. complete as per specifications, drawings and as directed by Engineer in charge - PLY STORAGE 900 mm W X 430 mm D X 1200 mm ---- as per directions of engineer in charge of work.

2

-

20000

... More
Concealed Conduit System :Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary - 19/20mm dia 2mm thick ---- as per directions of engineer in charge of work.

680

-

27200

... More
Concealed Conduit System :Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary - 25mm dia 2mm thick ---- as per directions of engineer in charge of work.

540

-

28620

... More
Supplying And Fixing Metal Fan Box with Round Hook. ---- as per directions of engineer in charge of work.

32

-

2720

... More
Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. - 19/20mm dia 2mm thick ---- as per directions of engineer in charge of work.

380

-

19380

... More
Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. - 25mm dia 2mm thick ---- as per directions of engineer in charge of work.

260

-

14040

... More
Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 1- Single Door II -Double Door Ill -Double Door - 4Way TP &N ---- as per directions of engineer in charge of work.

4

-

10600

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 1-3Way ---- as per directions of engineer in charge of work.

44

-

4180

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 4-5Way ---- as per directions of engineer in charge of work.

12

-

1260

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 6Way ---- as per directions of engineer in charge of work.

6

-

750

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 8Way ---- as per directions of engineer in charge of work.

38

-

5510

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 10-12Way ---- as per directions of engineer in charge of work.

10

-

1650

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 16-18Way ---- as per directions of engineer in charge of work.

10

-

1800

... More
Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. - Short point upto 3Mtr from tapping point to out let via switch box ---- as per directions of engineer in charge of work.

48

-

7680

... More
Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. - Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box ---- as per directions of engineer in charge of work.

76

-

19000

... More
Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. - Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box ---- as per directions of engineer in charge of work.

32

-

12000

... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.The following additional tests are compulsory either to be conducted at works or independent lab with witness by inspecting authority.Additional Tests for FRLS-Applicable Standard Oxygen Index -IS 694-1990, Clause 16.8 Temperature Index -IS 694-1990, Clause 16.13 Smoke Density -IS 694-1990, Clause 16.14 Test for Halogen Acid Gas evaluation -IS 694-1990, Clause 16.12 - 1.5 sqmm ---- as per directions of engineer in charge of work.

980

-

20090

... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.The following additional tests are compulsory either to be conducted at works or independent lab with witness by inspecting authority.Additional Tests for FRLS-Applicable Standard Oxygen Index -IS 694-1990, Clause 16.8 Temperature Index -IS 694-1990, Clause 16.13 Smoke Density -IS 694-1990, Clause 16.14 Test for Halogen Acid Gas evaluation -IS 694-1990, Clause 16.12 - 2.5 sqmm ---- as per directions of engineer in charge of work.

2800

-

89600

... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.The following additional tests are compulsory either to be conducted at works or independent lab with witness by inspecting authority.Additional Tests for FRLS-Applicable Standard Oxygen Index -IS 694-1990, Clause 16.8 Temperature Index -IS 694-1990, Clause 16.13 Smoke Density -IS 694-1990, Clause 16.14 Test for Halogen Acid Gas evaluation -IS 694-1990, Clause 16.12 - 4 sqmm ---- as per directions of engineer in charge of work.

440

-

19800

... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.The following additional tests are compulsory either to be conducted at works or independent lab with witness by inspecting authority.Additional Tests for FRLS-Applicable Standard Oxygen Index -IS 694-1990, Clause 16.8 Temperature Index -IS 694-1990, Clause 16.13 Smoke Density -IS 694-1990, Clause 16.14 Test for Halogen Acid Gas evaluation -IS 694-1990, Clause 16.12 - 6 sqmm ---- as per directions of engineer in charge of work.

420

-

29400

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 1 to 3 Module ---- as per directions of engineer in charge of work.

44

-

4840

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 4 Module ---- as per directions of engineer in charge of work.

12

-

1500

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 6 Module ---- as per directions of engineer in charge of work.

6

-

1050

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 8 Module ---- as per directions of engineer in charge of work.

38

-

7600

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 10-12 Module ---- as per directions of engineer in charge of work.

10

-

2300

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 16-18 Module ---- as per directions of engineer in charge of work.

10

-

2700

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. - 6Amps one way Switch ---- as per directions of engineer in charge of work.

312

-

21840

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. - 6Amps Two way Switch ---- as per directions of engineer in charge of work.

8

-

760

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. - 6Amps 3way socket ---- as per directions of engineer in charge of work.

124

-

13020

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. - Stepped Fan Regulator. ---- as per directions of engineer in charge of work.

32

-

9280

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. - 32Amps DP switch ---- as per directions of engineer in charge of work.

11

-

2002

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. - 6/16Amps universal socket ---- as per directions of engineer in charge of work.

11

-

1782

... More
Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- as per directions of engineer in charge of work.

102

-

10812

... More
Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- as per directions of engineer in charge of work.

11

-

13200

... More
Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / Watt, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 °C by resistance method at 245 Volts, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, watt& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty. - 48" Sweep 5 Star (1200mm) ---- as per directions of engineer in charge of work.

32

-

92800

... More
Supplying wall mounting fan suitable to operate at single- phase 230v AC. supply. - 400mm Sweep ---- as per directions of engineer in charge of work.

1

-

2800

... More
Supplying & fixing of Surface mounting type retrofit type -LED tube ....... W comprising of LED linear source with CCT 6500 degree K, CRI> 70%. efficacy >80 lumen per watt, life> 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF > 0.95, power loss should < 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. - 18W-20W (T8) Polycarbonate/OPAL Acrylic Casing ---- as per directions of engineer in charge of work.

76

-

32300

... More
Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI> 70%. efficacy > 100 lumen per watt, 120degree beam spread, life> 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF > 0.95, power loss should< 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. - LED modular down light 1 'x1' 34 -22watts ---- as per directions of engineer in charge of work.

4

-

10568

... More
Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI> 70%. efficacy > 100 lumen per watt, 120degree beam spread, life> 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF > 0.95, power loss should< 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. - LED modular down light 2'x2' /1' X 4' 34 -36watt ---- as per directions of engineer in charge of work.

2

-

10400

... More
Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI> 70%. efficacy >80 lumen per watt, life> 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF > 0.95, power loss should < 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. - 18W, 6500K ---- as per directions of engineer in charge of work.

46

-

11730

... More
Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps. - On wall/ ceiling / Rafter / Girders ---- as per directions of engineer in charge of work.

82

-

9020

... More
Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ---- as per directions of engineer in charge of work.

33

-

4950

... More
Extra length of GI pipe of class B 19mm dia for down rod. ---- as per directions of engineer in charge of work.

24

-

3840

... More
Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 amps. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. ---- as per directions of engineer in charge of work.

11

-

4400

... More
Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. - Remote ---- as per directions of engineer in charge of work.

6

-

6204

... More
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - 6-32Amps DP ---- as per directions of engineer in charge of work.

16

-

14544

... More
Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V up to 300mA sensitivity on existing wood/panel board. - 16-25 Amps 2 pole ---- as per directions of engineer in charge of work.

4

-

9200

... More
Supplying, erecting, testing & commissioning of OFF- LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with all accessories complete and Excluding batteries and wiring complete. - 5 KVA OFF LINE UPS Note: For item 10.2 batteries are required for backup power supply- 1) 1 KVA off line UPS one hour backup : 2 x 40 AH batteries. 2) 2 KVA off line UPS one hour backup : 3 x 80 AH batteries. 3) 5 KVA off line UPS one hour backup : 6 x 80 AH batteries. ---- as per directions of engineer in charge of work.

1

-

37100

... More
Supplying, installation, testing & commissioning of 12Volts ..AH batteries in poly propylene container for D.G. sets. Low maintenance batteries, plate type. - 150 AH capacity ---- as per directions of engineer in charge of work.

6

-

135000

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. - RJ45/I.O.outlet Cat-6 ---- as per directions of engineer in charge of work.

30

-

5850

... More
Supplying and drawing UTP-CAT 6E LAN cable. ---- as per directions of engineer in charge of work.

860

-

24940

... More
Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. - 2Pair ---- as per directions of engineer in charge of work.

140

-

2030

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. - TV/Telephone socket ---- as per directions of engineer in charge of work.

3

-

237

... More
Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6. ---- as per directions of engineer in charge of work.

60

-

2100

... More
Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. - 63Amps ---- as per directions of engineer in charge of work.

3

-

681

... More
Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution) - 63Amps ---- as per directions of engineer in charge of work.

1

-

5300

... More
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (Icu=lcs) THREE POLE FOUR POLE - 100Amps 25kA ---- as per directions of engineer in charge of work.

1

-

6400

... More
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - 6-32Amps TPN ---- as per directions of engineer in charge of work.

3

-

5145

... More
Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. ---- as per directions of engineer in charge of work.

1

-

7700

... More
Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter ---- as per directions of engineer in charge of work.

1

-

1185

... More
Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound. ---- as per directions of engineer in charge of work.

3

-

1404

... More
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. ---- as per directions of engineer in charge of work.

3

-

1290

... More
Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. - 100Amps 4x30x6mm Aluminium Strips ---- as per directions of engineer in charge of work.

1.2

-

2460

... More
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. - 40x40x6mm ---- as per directions of engineer in charge of work.

12

-

3060

... More
Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. - 16SWG ---- as per directions of engineer in charge of work.

64000

-

22400

... More
Supplying PVC/GI flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely - 25mm ---- as per directions of engineer in charge of work.

28

-

784

... More
Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. - 25x6mm Copper strip ---- as per directions of engineer in charge of work.

1.2

-

1149.6

... More
Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. - 8 SWG Copper wire. ---- as per directions of engineer in charge of work.

24

-

2520

... More
Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. ---- as per directions of engineer in charge of work.

4

-

16600

... More
Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 - 3.5 core 35 sqmm ---- as per directions of engineer in charge of work.

160

-

36000

... More
Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe/ stoneware pipe /on wall / on pole as required. In existing trench/duct. On wall/Structure - 25 sqmm to 75 sqmm ---- as per directions of engineer in charge of work.

140

-

2170

... More
Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc. complete.(As per Civil SR KSRB 1-2, P-7) - In soil (hard) ---- as per directions of engineer in charge of work.

130

-

13260

... More
Providing and laying in position 100mm dia stone ware pipe in existing trench. ---- as per directions of engineer in charge of work.

10

-

2150

... More
Supplying and fixing LT cast Iron pot heads suitable for 1.1KV class UG cable filled with necessary bitumen/insulating compound complete with terminals, clamps, bolts, nuts and washers etc. - 25Sqmm ---- as per directions of engineer in charge of work.

2

-

700

... More
Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) - 50mm dia ---- as per directions of engineer in charge of work.

2

-

510

... More
Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. - 35 sqmm Long Barrel ---- as per directions of engineer in charge of work.

16

-

512

... More
LED Street light : .Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT > 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire > IK08. Power Factor >0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency>1301m/w, nominal CRI >75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. - LED Streetlight 70 Watts ---- as per directions of engineer in charge of work.

4

-

21920

... More
Supplying and Fixing of........mm dia class A GI pipe bracket up to 2 Mtrs long bent at suitable angle and fixing to this bracket 1x40/2x40 watts fluorescent tube street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires. - Using 25mm dia G.I.Pipe ---- as per directions of engineer in charge of work.

4

-

3100

... More
Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990. - 3C X 2.5Sq.mm ---- as per directions of engineer in charge of work.

130

-

12740

... More
Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 volts 1/3 phase motor upto 5 HP. ---- as per directions of engineer in charge of work.

2

-

2760

... More
Supplying and fixing single phase preventer using necessary wires over an existing panel board suitable for motor up to 20 HP capacities. ---- as per directions of engineer in charge of work.

1

-

745

... More
Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machineries like induction motor. ---- as per directions of engineer in charge of work.

2

-

800

... More
Fixing a shunt capacitor of ... KVAR capacity with necessary clamps, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor. - 6 to 10 KVAR ---- as per directions of engineer in charge of work.

2

-

382

... More
Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws. - 12"x12"x2" ---- as per directions of engineer in charge of work.

2

-

300

... More
Supplying, fixing and wiring 0 to 600Volts 96x96mm AC Voltmeter on existing panel/wood board. ---- as per directions of engineer in charge of work.

1

-

377

... More
Supplying, fixing and wiring 0 to 30amps Direct Reading AC analog type Ammeter ---- as per directions of engineer in charge of work.

1

-

387

... More
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. ---- as per directions of engineer in charge of work.

3

-

1290

... More
Supplying, installation, testing and commissioning of solar hot water heater comprising of high quality Evacuated Glass Tube (EGT) with absorber coating collector of size 58 x 1800 mm. Inner tank Material-Stainless steel 304-L Grade with Aluminium Stucco cladding made of High quality PUF insulation to minimizes heat loss and hold water Temperature upto 72 Hrs...with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. Fitted with Sacrificial Anode - 200 Liter capacity- 20 nos Tubes ---- as per directions of engineer in charge of work.

1

-

46000

... More
Supplying of .. TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 Volts with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit. - 1.5 ton capacity 5 star ---- as per directions of engineer in charge of work.

1

-

53000

... More
Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support up to 3.0 ton split/cassette type A/C. ---- as per directions of engineer in charge of work.

1

-

2900

... More
Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tube. - Split ---- as per directions of engineer in charge of work.

4

-

4620

... More
Supplying, erecting, testing and commissioning of voltage stabilizer suitable for 170 to 270 V input and load variation from no load to full load, with over load protection, spike suppression, operating at 00 C to 400 C. Range etc., complete. - 5KVA Capacity ---- as per directions of engineer in charge of work.

1

-

4510

... More
Supplying & Fixing of switch mounting rack with power manager & Cable manager. - 18U with 650mm depth ---- as per directions of engineer in charge of work.

1

-

16500

... More
Supplying & fixing of I/O socket with back box - Single I/O ---- as per directions of engineer in charge of work.

30

-

9900

... More
Supplying & Fixing of Patch panel for LAN cabling - 24 Port 101100 patch panel ---- as per directions of engineer in charge of work.

1

-

3800

... More
Supplying fixing of Network Switches - 24 port 10/100/1000 Switch ---- as per directions of engineer in charge of work.

1

-

6800

... More
Supplying & Fixing of Power strip ---- as per directions of engineer in charge of work.

1

-

1000

... More
Fixing charges for Flush door shutter- 35mm thick both side Teak GF ---- as per directions of engineer in charge of work.

11.99

-

4796

... More
Fixing charges for Flush door shutter- 35mm thick both side Teak FF ---- as per directions of engineer in charge of work.

11.99

-

4796

... More
Fixing charges for Flush door shutter- 35mm thick both side Teak SF ---- as per directions of engineer in charge of work.

4.1

-

1640

... More
Fixing charges for Flush door shutter- 30mm thick both side Teak GF ---- as per directions of engineer in charge of work.

7.18

-

2872

... More
Fixing charges for Flush door shutter- 30mm thick both side Teak FF ---- as per directions of engineer in charge of work.

7.18

-

2872

... More
Fixing charges for Flush door shutter- 30mm thick both side Teak SF ---- as per directions of engineer in charge of work.

11.79

-

4716

... More
Providing Patti around doors, windows, ventilators ---- as per directions of engineer in charge of work.

267

-

13350

... More
Providing Grooves in plasteringon walls ---- as per directions of engineer in charge of work.

1945.2

-

87534

... More
Plantation of fruit trees ---- as per directions of engineer in charge of work.

4

-

200

... More
Providing and fixing Jaquar / Hindware / Parry ware or equivalent Short body cock/ tap ---- as per directions of engineer in charge of work.

14

-

17500

... More
Providing and fixing Jaquar / Hindware / Parry ware or equivalent Long body cock/ tap ---- as per directions of engineer in charge of work.

8

-

10800

... More
Providing and fixing Jaquar / Hindware / Parry ware or equivalent Angle stop cock ---- as per directions of engineer in charge of work.

20

-

25000

... More
Providing and fixing Jaquar / Hindware / Parry ware or equivalent Two way bib cock ---- as per directions of engineer in charge of work.

7

-

9450

... More
Providing and fixing Jaquar / Hindware / Parry ware or equivalent Health faucet ---- as per directions of engineer in charge of work.

9

-

12150

... More
Providing 10cms dia PVC cowl with cap ---- as per directions of engineer in charge of work.

5

-

250

... More
Providing and laying in cement concrete of mix M30 with OPC cement @ 360kgs, vibrated for all works Bottom raft ---- as per directions of engineer in charge of work.

4.7

-

27330.5

... More
Providing and removing centering for vertical surfaces ---- as per directions of engineer in charge of work.

18.68

-

6724.8

... More
Providing & fixing MS inspection Door ---- as per directions of engineer in charge of work.

1

-

1260

... More
Providing & fixing MS ladder ---- as per directions of engineer in charge of work.

2

-

1400

... More
Providing & fixing MS inspection Door ---- as per directions of engineer in charge of work.

1

-

1260

... More
Geo physical investigation of site for sinking of bore well ---- as per directions of engineer in charge of work.

1

-

3768

... More
Sinking Bore well of 165 mm dia, upto 50mtrs depth ---- as per directions of engineer in charge of work.

50

-

17350

... More
Sinking Bore well of 165 mm dia, above 51mtrs and upto 100mtrs. ---- as per directions of engineer in charge of work.

50

-

22100

... More
Sinking Bore well of 165 mm dia, Above 100m and upto 150mtrs. ---- as per directions of engineer in charge of work.

50

-

22800

... More
Sinking Bore well of 165 mm dia, Above 150m and upto 200mtrs. ---- as per directions of engineer in charge of work.

50

-

26800

... More
Providing & installing at site of work P.V.C pipes ---- as per directions of engineer in charge of work.

150

-

116700

... More
Providing and fixing MS collars ---- as per directions of engineer in charge of work.

6

-

900

... More
Providing and fixing MS caps ---- as per directions of engineer in charge of work.

1

-

100

... More
Providing Patti around doors, windows, ventilators ---- as per directions of engineer in charge of work.

361.5

-

18075

... More
Providing & Installing Free standing table ---- as per directions of engineer in charge of work.

3

-

52830

... More
Providing & Installing Metal Tandem chair three seater ---- as per directions of engineer in charge of work.

3

-

19974

... More
Providing & Installing Fixed type Visitor chair ---- as per directions of engineer in charge of work.

4

-

16568

... More
Providng & installing revolving type Executive chair ---- as per directions of engineer in charge of work.

4

-

88768

... More
Providing and fixing of Signage boards ---- as per directions of engineer in charge of work.

1

-

95000

... More
Providng & installing revolving type Malaysian Computer chair ---- as per directions of engineer in charge of work.

8

-

28600

... More
Providng & installing visitors chair ---- as per directions of engineer in charge of work.

12

-

41760

... More
Supplying and fixing cast Aluminium round or oblong type bulk head fitting with GI wire guard, glass cover with 15Watts 230V CFL lamp as required ---- as per directions of engineer in charge of work.

4

-

3808

... More
Supplying of Single Phase Open well Mono sub pump set 1.5 HP suitable for operation on 230 volts Single phase AC supply Make- Using group "A" materials. And as per the directions of engineer incharge of the work. ---- as per directions of engineer in charge of work.

1

-

10867

... More
Supplying and Delivery at Site 2 HP 20 Stage single phase 4 inch/100mm Submersible Pump set of approved make ISI with Motor. Suitable for operation of three Phase 50 HZ 440 Volts A.C supply fitted with required accessories complete as per the approved rate Make - Make:Kirloskar/Calama/Lubi/Atlanta/Texmo/Suguna and as per the directions of Engineer in charge of the work. ---- as per directions of engineer in charge of work.

1

-

19579

... More
Providing and fixing to wall, ceiling and floor high density polyethylene pipes 6.00 kgf/sq.cm working pressure of outside diameter raising mains & exposed distribution pipes with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor,, including cost of all materials, labour charges, HOM and testing complete as per specifications. 40mm dia. ---- as per directions of engineer in charge of work.

130

-

34060

... More
Supplying, installation and erection of Gate valve of 50 mm dia. ---- as per directions of engineer in charge of work.

1

-

1800

... More
Supplying, installation and erection of Non Return valve of 50 mm dia. ---- as per directions of engineer in charge of work.

1

-

1800

... More
Supplying, installation and erection of Borewell cap and clamp set. ---- as per directions of engineer in charge of work.

1

-

1800

... More
Providing and fixing chlorinated poly vinyl chloride (CPVC ) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all C P V C plain and brass threaded fittings, including fixing the pipe with clamp at 1.00 mtrs spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete ( external work) a) for 40mm nominal OD Pipe ---- as per directions of engineer in charge of work.

20

-

5840

... More
"Providing and fixing chlorinated poly vinyl chloride (CPVC ) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all C P V C plain and brass threaded fittings, including fixing the pipe with clamp at 1.00 mtrs spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete ( external work) a) for 25mm diaMake- group ""A"" materials. And as per the directions of engineer incharge of the work. " ---- as per directions of engineer in charge of work.

20

-

3300

... More
"Providing and fixing chlorinated poly vinyl chloride (CPVC ) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all C P V C plain and brass threaded fittings, including fixing the pipe with clamp at 1.00 mtrs spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete ( external work) a) for 20mm nominal OD Pipe Make- group ""A"" materials. And as per the directions of engineer incharge of the work. " ---- as per directions of engineer in charge of work.

20

-

3580

... More
Providing and fixing in position brass Gate Valve with C.I. wheel of app. Quality (Screw End) 40mm nominal bore including cost of all materials, labour and HOM of equipments with all leed complete as per specifications. a) for 40mm dia nominal ---- as per directions of engineer in charge of work.

2

-

2226

... More
Providing and fixing in position brass Gate Valve with C.I. wheel of app. Quality (Screw End) 40mm nominal bore including cost of all materials, labour and HOM of equipments with all leed complete as per pecifications. a) for 25 mm dia nominal Make- group "A" materials. And as per the directions of engineer incharge of the work. ---- as per directions of engineer in charge of work.

2

-

1014

... More
Supply and installation of 25 lts Water prifier as per the directions of the engineer incharge of the work ( approved make ) ---- as per directions of engineer in charge of work.

1

-

25000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.