Karnataka State Police Housing And Infrastructure Development Corporation Limited Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Karnataka State Police Housing And Infrastructure Development Corporation Limited - KSPHCL Tender

Civil And Construction
Building Construction
Opening Date17 Jun 2022
Closing Date24 Jun 2022
Tender Amount₹ 1,92,13,994 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and laying in position plain cement concrete Mix 1:4:8( M5) Using 40 mm and down size graded crushed coarse aggregates for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

113.13

-

637170.79

... More
Providing and laying in position Reinforced cement concrete M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

91.4

-

645827.83

... More
Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

91.95

-

508419.14

... More
Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground floor ---- As per directions of engineer in charge of work.

19.88

-

148583.32

... More
Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First floor ---- As per directions of engineer in charge of work.

14.3124

-

108040.59

... More
Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Terrece floor ---- As per directions of engineer in charge of work.

2.5216

-

19223.39

... More
Providing and laying in position Reinforced cement concrete M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. for Plinth beam ---- As per directions of engineer in charge of work.

26.5133

-

179385.28

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceed- ing 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

267.219

-

57238.31

... More
Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

416.6576

-

175871.17

... More
Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

495.36

-

49412.16

... More
Providing and constructing load bearing wall with Solid Concrete blocksof size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground floor ---- As per directions of engineer in charge of work.

587.748

-

658483.47

... More
Providing and constructing load bearing wall with Solid Concrete blocksof size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First floor ---- As per directions of engineer in charge of work.

441.045

-

499064.47

... More
Providing and constructing load bearing wall with Solid Concrete blocksof size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Terrece floor ---- As per directions of engineer in charge of work.

136.755

-

156278.14

... More
Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Grond floor ---- As per directions of engineer in charge of work.

79.9425

-

79406.89

... More
Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First floor ---- As per directions of engineer in charge of work.

104.445

-

104782.36

... More
Providing and laying in position plain cement concrete Mix 1:3:6 (M10) Using 20 mm and down size graded crushed coarse aggregates for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor ---- As per directions of engineer in charge of work.

2.495

-

15990.38

... More
Providing and laying in position plain cement concrete Mix 1:3:6 (M10) Using 20 mm and down size graded crushed coarse aggregates for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor ---- As per directions of engineer in charge of work.

2.121

-

13729.36

... More
Providing and laying in position plain cement concrete Mix 1:3:6 (M10) Using 20 mm and down size graded crushed coarse aggregates for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Terrece Floor ---- As per directions of engineer in charge of work.

1.5075

-

9854.75

... More
Providing and laying in position Reinforced cement concrete M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates, for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. for Staircase Ground Floor ---- As per directions of engineer in charge of work.

4.0365

-

32911.44

... More
Providing and laying in position Reinforced cement concrete M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates, for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. for Staircase First Floor ---- As per directions of engineer in charge of work.

4.0365

-

33240.54

... More
Providing and laying in position Reinforced cement concrete M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates, for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. for Lintel Ground Floor ---- As per directions of engineer in charge of work.

6.2859

-

51251.83

... More
Providing and laying in position Reinforced cement concrete M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates, for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. for Lintel First Floor ---- As per directions of engineer in charge of work.

6.321

-

52053.37

... More
Providing and laying in position Reinforced cement concrete M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates, for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. for Beams Ground Floor ---- As per directions of engineer in charge of work.

20.4359

-

166623.29

... More
Providing and laying in position Reinforced cement concrete M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates, for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. for Beams First Floor ---- As per directions of engineer in charge of work.

14.8571

-

122348.07

... More
Providing and laying in position Reinforced cement concrete M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates, for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. for Beams Terrece Floor ---- As per directions of engineer in charge of work.

14.8571

-

123559.52

... More
Providing and laying in position Reinforced cement concrete M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates, for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. for Staircase, Lintels and Beams Ground Floor ---- As per directions of engineer in charge of work.

1.296

-

12768.32

... More
Providing and laying in position Reinforced cement concrete M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates, for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. for Staircase, Lintels and Beams First Floor ---- As per directions of engineer in charge of work.

1.89

-

18806.67

... More
Providing lath plaster with cemen tmortar 1:3,Scmsthick with 6mm dia mild steel bars at 20ems.ctoc both horizontally and verticallyfixed withchickenmesh for drop chajja.facia, backingtocup board sincluding cost of all materials,labour,providing and removing formwork usagecharges, curing,complete as per specifications. with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

33

-

41649.3

... More
Providing and laying in position Reinforced cement concrete M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates, for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. for Roof slab Ground Floor ---- As per directions of engineer in charge of work.

68.424

-

557892.35

... More
Providing and laying in position Reinforced cement concrete M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates, for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. for Roof slab First Floor ---- As per directions of engineer in charge of work.

62.7075

-

516395.64

... More
Providing and laying in position Reinforced cement concrete M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates, for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. for Roof slab Terrece Floor ---- As per directions of engineer in charge of work.

5.4003

-

44911.76

... More
KSRB 4-1.5 : Providing and laying in position plain cement concrete of mix M20 with OPC cement @ 300kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregtes @ 0.43cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, plinth and cills, including cost of all materials, labour, HOM of machinery, curing complete as per specifications.Specification No. KBS 4.1, 4.2 Sl.No-4.5/P-12 with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Screed concrete with WPC over roof slab. Ground Floor ---- As per directions of engineer in charge of work.

2.925

-

16987.08

... More
KSRB 4-1.5 : Providing and laying in position plain cement concrete of mix M20 with OPC cement @ 300kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregtes @ 0.43cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, plinth and cills, including cost of all materials, labour, HOM of machinery, curing complete as per specifications.Specification No. KBS 4.1, 4.2 Sl.No-4.5/P-12 with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.. For Screed concrete with WPC over roof slab. First Floor ---- As per directions of engineer in charge of work.

34.0539

-

197769.73

... More
Providing Thermo-Mechanically Treated bars of grade Fe-500 D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor ---- As per directions of engineer in charge of work.

18232.33

-

2029258.33

... More
Providing Thermo-Mechanically Treated bars of grade Fe-500 D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor ---- As per directions of engineer in charge of work.

8720.19

-

980236.56

... More
Providing Thermo-Mechanically Treated bars of grade Fe-500 D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Terrece Floor ---- As per directions of engineer in charge of work.

599.33

-

68041.93

... More
Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ground Floor ---- As per directions of engineer in charge of work.

343.2038

-

118559.75

... More
Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. First Floor ---- As per directions of engineer in charge of work.

491.7

-

171554.13

... More
Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Terrece Floor ---- As per directions of engineer in charge of work.

53.77

-

18946.4

... More
Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. for ceiling Ground Floor ---- As per directions of engineer in charge of work.

404.939

-

115865.2

... More
Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. for ceiling First Floor ---- As per directions of engineer in charge of work.

208.3476

-

60210.37

... More
Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. for ceiling Terrece Floor ---- As per directions of engineer in charge of work.

20.16

-

5883.7

... More
Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. for inside walls Ground Floor ---- As per directions of engineer in charge of work.

973.845

-

278646.27

... More
Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. for inside walls First Floor ---- As per directions of engineer in charge of work.

968.8838

-

279997.73

... More
Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. for inside walls Terrece Floor ---- As per directions of engineer in charge of work.

44.22

-

12905.61

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Ground Floor ---- As per directions of engineer in charge of work.

1415.964

-

123401.26

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. First Floor ---- As per directions of engineer in charge of work.

1216.3114

-

106001.54

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Terrece Floor ---- As per directions of engineer in charge of work.

64.38

-

5610.72

... More
Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ground Floor ---- As per directions of engineer in charge of work.

128.1375

-

31483.38

... More
Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. First Floor ---- As per directions of engineer in charge of work.

175.6125

-

43580

... More
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor ---- As per directions of engineer in charge of work.

57.15

-

172881.61

... More
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor ---- As per directions of engineer in charge of work.

21.375

-

65307.04

... More
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor ---- As per directions of engineer in charge of work.

424.069

-

494697.69

... More
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor ---- As per directions of engineer in charge of work.

192.7176

-

227063.73

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. for Ceramic Tiles of size 30x30cms Fixing glazed / Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor ---- As per directions of engineer in charge of work.

20.95

-

23251.36

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. for Ceramic Tiles of size 30x30cms Fixing glazed / Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor ---- As per directions of engineer in charge of work.

37.15

-

41643.29

... More
Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor ---- As per directions of engineer in charge of work.

128.1375

-

279179.58

... More
Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor ---- As per directions of engineer in charge of work.

175.6125

-

386442.33

... More
Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor ---- As per directions of engineer in charge of work.

0.668

-

63401.65

... More
Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor ---- As per directions of engineer in charge of work.

0.661

-

63364.64

... More
Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor ---- As per directions of engineer in charge of work.

12

-

18711

... More
Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor ---- As per directions of engineer in charge of work.

11

-

17323.24

... More
Providing and fixing in position fully panelled Honne wood shutters for doors with , stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor ---- As per directions of engineer in charge of work.

17.01

-

86909.19

... More
Providing and fixing in position fully panelled Honne wood shutters for doors with , stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor ---- As per directions of engineer in charge of work.

14.175

-

73148.53

... More
Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side Teak with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor ---- As per directions of engineer in charge of work.

5.67

-

13889.52

... More
Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side Teak with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor ---- As per directions of engineer in charge of work.

7.56

-

18704.57

... More
Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor ---- As per directions of engineer in charge of work.

30.6

-

15261.75

... More
Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor ---- As per directions of engineer in charge of work.

40.8

-

20552.59

... More
Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with one side prelam with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor ---- As per directions of engineer in charge of work.

9.45

-

28338.66

... More
Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with one side prelam with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor ---- As per directions of engineer in charge of work.

12.6

-

38162.75

... More
Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size – 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor ---- As per directions of engineer in charge of work.

67.05

-

509714.1

... More
Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size – 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor ---- As per directions of engineer in charge of work.

70.74

-

543143.13

... More
Providing and fixing M.S. grills of required pattern in frames of win- dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor ---- As per directions of engineer in charge of work.

3179.25

-

570834.34

... More
Providing and fixing M.S. grills of required pattern in frames of win- dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor ---- As per directions of engineer in charge of work.

1061.1

-

192430.48

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specificationswith all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

630

-

330750

... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m� over and including priming coat of exterior primer applied @ 2.20 kg/10 m�) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications awith all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor ---- As per directions of engineer in charge of work.

409.2038

-

58434.3

... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m� over and including priming coat of exterior primer applied @ 2.20 kg/10 m�) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor ---- As per directions of engineer in charge of work.

491.7

-

70917.89

... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m� over and including priming coat of exterior primer applied @ 2.20 kg/10 m�) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Terrece Floor ---- As per directions of engineer in charge of work.

53.77

-

7832.14

... More
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. for ceiling Ground Floor ---- As per directions of engineer in charge of work.

404.939

-

40392.67

... More
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. for ceiling First Floor ---- As per directions of engineer in charge of work.

208.3476

-

20991.02

... More
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specificationswith all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. for ceiling Third Floor ---- As per directions of engineer in charge of work.

20.16

-

2051.28

... More
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. for inside walls Ground Floor ---- As per directions of engineer in charge of work.

973.845

-

97141.04

... More
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. for inside walls First Floor ---- As per directions of engineer in charge of work.

369.6

-

37237.2

... More
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. for inside walls Third Floor ---- As per directions of engineer in charge of work.

56.58

-

5757.01

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor ---- As per directions of engineer in charge of work.

133.389

-

18207.6

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specificationswith all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor ---- As per directions of engineer in charge of work.

132.165

-

18221.59

... More
Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

126.8

-

40873.98

... More
Providing patti alround doors, windows, ventilators and for parapet & compound wall etc., with CM 1:3 & finished as per design and specifications including scaffolding etc., completewith all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

166.2

-

2396.6

... More
Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

600

-

25200

... More
Providing and fixing Stainless Steel door fixtures of approved make and quality,including cost and conveyance of all materials, fixing labour charges and HOM of equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.(Refer general specification of tender document) with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Main Doors ---- As per directions of engineer in charge of work.

11.97

-

7541.1

... More
Providing and fixing Stainless Steel door fixtures of approved make and quality,including cost and conveyance of all materials, fixing labour charges and HOM of equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.(Refer general specification of tender document) with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Internal Doors ---- As per directions of engineer in charge of work.

30.24

-

12700.8

... More
Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

481.35

-

376536.04

... More
Providing and laying heavy duty cobble stones 75mm thick interlock pavers, using cement and course sand for manufacture of blocks of approved size, shape and colour with a minimum compressive strength of 281 kg per m2 over 50mm thick sand bed ( average thickness ) and compacting with plate vibrator having 3 tons compaction force thereby forcing part of sand underneath to come up in between joints, final compaction of paver surface joints into its final level, including cost of materials, labour and Usage charges of machinery complete as per specifications. with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

72.25

-

86862.56

... More
Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per thedirection of Engineer in charge. 0.63 mm thick with zinc coating not less than 275 g/ m�0.63 mm thick with zinc coating not less than 275 g/ m� with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

67.5

-

56345.62

... More
Providing and fixing in position 12mm thick plaster of paris (Gypsum anhydrous) for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications. with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

50.75

-

62399.66

... More
Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/ beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

70.47

-

291460.4

... More
Providing, supplying and fixing signage board with all lead and lift etc completed ---- As per directions of engineer in charge of work.

1

-

75000

... More
Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

198.86

-

98137.41

... More
Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

198.86

-

25473.97

... More
Providing and fixing chorinated poly venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and coldwater supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (internal work exposed on wall)(Pg.No.94/I.No.13.85.3&13.85.4) with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. 20 mm toilet out side ---- As per directions of engineer in charge of work.

75

-

16931.25

... More
Providing and fixing chorinated poly venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and coldwater supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (internal work exposed on wall)(Pg.No.94/I.No.13.85.3&13.85.4) with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. 25 mm delivery lines ---- As per directions of engineer in charge of work.

150

-

47092.5

... More
Providing and fixing chorinated poly venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and coldwater supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (internal work exposed on wall)(Pg.No.94/I.No.13.85.3&13.85.4) with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. 32 mm Sump tank to ver head tank ---- As per directions of engineer in charge of work.

100

-

37590

... More
Providing and fixing chorinated poly venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and coldwater supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (internal work exposed on wall)(Pg.No.94/I.No.13.85.3&13.85.4) with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. 40 mm Bore well to sump tank ---- As per directions of engineer in charge of work.

75

-

36933.75

... More
KSRB13-8.1 : Providing and fixing to wall, ceiling and floor, mediumdensity polyethylene pipes 6.00 kgs/sq.cm working pressure 20mmoutside diameter with special flange, compression type fittings, wall clips,making good the wall, ceiling and floor including cost of all materials, labourcharges, HOM of equipments and testing complete as per specifications.Specification No.KBS 13.2.15.1 / 13.9 for internal water supply connection(P.No91/Sl.No 13.70.2,3,4&6) with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. 75mm ---- As per directions of engineer in charge of work.

70

-

15435

... More
KSRB13-8.1 : Providing and fixing to wall, ceiling and floor, mediumdensity polyethylene pipes 6.00 kgs/sq.cm working pressure 20mmoutside diameter with special flange, compression type fittings, wall clips,making good the wall, ceiling and floor including cost of all materials, labourcharges, HOM of equipments and testing complete as per specifications.Specification No.KBS 13.2.15.1 / 13.9 for internal water supply connection(P.No91/Sl.No 13.70.2,3,4&6) with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. 90mm & Rain water pipe ---- As per directions of engineer in charge of work.

180

-

53109

... More
KSRB13-8.1 : Providing and fixing to wall, ceiling and floor, mediumdensity polyethylene pipes 6.00 kgs/sq.cm working pressure 20mmoutside diameter with special flange, compression type fittings, wall clips,making good the wall, ceiling and floor including cost of all materials, labourcharges, HOM of equipments and testing complete as per specifications.Specification No.KBS 13.2.15.1 / 13.9 for internal water supply connection(P.No91/Sl.No 13.70.2,3,4&6) with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. 110mm ---- As per directions of engineer in charge of work.

150

-

62055

... More
KSRB13-8.1 : Providing and fixing to wall, ceiling and floor, mediumdensity polyethylene pipes 6.00 kgs/sq.cm working pressure 20mmoutside diameter with special flange, compression type fittings, wall clips,making good the wall, ceiling and floor including cost of all materials, labourcharges, HOM of equipments and testing complete as per specifications.Specification No.KBS 13.2.15.1 / 13.9 for internal water supply connection(P.No91/Sl.No 13.70.2,3,4&6) with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. 160mm ---- As per directions of engineer in charge of work.

75

-

47171.25

... More
Providing and fixing in position Pillar cock of Jaquar/Hindware/Parry ware of approved quality 20mm nominal bore including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

6

-

7500

... More
Providing and fixing in position Short body cock/tap of Jaquar/Hindware/Parry ware of approved quality 20mm nominal bore including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

5

-

6250

... More
Providing and fixing in position Long body cock/tap of Jaquar/Hindware/Parry ware of approved quality 20mm nominal bore including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

4

-

5400

... More
Providing and fixing in position Angle stop cock of Jaquar/Hindware/Parry ware of approved quality 20mm nominal bore including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

6

-

7500

... More
Providing and fixing in position Two way bib cock of Jaquar/Hindware/Parry ware of approved quality 20mm nominal bore including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

2

-

2700

... More
Providing and fixing in position Health faucet complete set of Jaquar/Hindware/Parry ware of approved quality 20mm nominal bore including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

2

-

2700

... More
Providing and fixing CI Nahani trap of approved make conforming to ISI specifications and construction of Cistern in M-15 as per directions (Rate is inclusive of cost of materials and fixtures and conveyance of materials to work spot).with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

10

-

4987.5

... More
KSRB 13-11.1 : Providing and placing on terrace, polyethylene water storage tanks as per IS 12701 : 1996 with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials, labour, transport charges, HOM of equipments and testing complete as per specifications.(For 1000 litre capacity) Specification No.KBS 13.22. Sl.No-13.78/P-82. with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

1000

-

8400

... More
Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. Supply and fixing of SFRC machinhole cover heavy duty made as per IS to suit existing damaged machinhole cover after removing the debries from inside and outside the existing machinhole etc with all lead and lifts. with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

12

-

77401.8

... More
Constructing brick masonary chamber of internal dimension 450x450mm and depth of 600 mm (innder dimensions) with modular bricks of CD 75 in CM 1:6 bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with CM 1:4 CC 1:2:4 coping 75mm thick for fixing CI cover and frame etc., excluding the cost of CI frmae and cover. Supply and fixing of SFRC machinhole cover heavy duty made as per IS to suit existing damaged machinhole cover after removing the debries from inside and outside the existing machinhole etc with all lead and lifts. with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

10

-

52815

... More
Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. 25mm dia ---- As per directions of engineer in charge of work.

3

-

1663.2

... More
Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. 32mm dia ---- As per directions of engineer in charge of work.

2

-

1211.7

... More
Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. 40mm dia ---- As per directions of engineer in charge of work.

2

-

1430.1

... More
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

7

-

36786.75

... More
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

6

-

26749.8

... More
Providing and fixing white vitreous china wash basin including making all connections but including the cost of fittings : Flat back wash basin of size 630x450 mm with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

10

-

22638

... More
Making wall bores in brick masonry walls up to 0.45 m thick with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work..Sl.No-37.35/P-234. ---- As per directions of engineer in charge of work.

25

-

3307.5

... More
Providing & fixing Adanga marble partitions at urnals with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

7.5

-

9725.62

... More
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

10

-

10195.5

... More
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

10

-

3990

... More
Providing 10cms dia PVC cowl with cap of approved 1 st quality and make conforming to ISI specifications and fixing in position as directed (Rate includes cost of materials fixtures including conveyance charges to the work spot) (Pg.No.XXXVI) with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

2

-

480.9

... More
Providing and fixing 7.5 cms to 15.00 cms dia NP grating 100 mm dia. with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work..Sl.No-12.111/P-86. ---- As per directions of engineer in charge of work.

12

-

1890

... More
KSRB13-3.1: Providing and fixing in trenches galvanised /mild steel tubes (medium grade) 50mm dia nominal bore with all fittings (earth work in trenches to be measured and paid for separately) including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. Specification No.KBS 13.2.14 / 13.6 P-88, Ino13.15 with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

5

-

2037

... More
Providing and fixing white vitreous china clay Urinals with flat back of approved make fixed to wooden plugs including bends, painting white to exposed pipes etc., complete as per directions. (Rate includes cost of all materials and lead). A grade ( P no 77, I no 12.109) with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

6

-

6331.5

... More
KSRB15-3.11 : Providing 20mm thick cement plaster in single coat with cement mortar 1:4, to stone masonry & concrete surface including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications.KSRB15-4.5 Extra for providing and mixing waterproofing compound in cement plaster for stone masonry work at one kg per bag or in the proportion recommended by the manufacturers, for cement mortar 1:4, 20mm thick cost of materials complete as per specifications..Sl.No-15.19 & 15.27/P-111.2 with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

39.4

-

11542.23

... More
Providing & fixing 60cms X 60 cms size MS inspection door with necessary MS frame made out of MS Angle of 50 mm X 50 mm X 6mm and MS shutters of 3 mm thickness with hinges on top and locking arrangements painting etc., complete for RCC Sump tank. PRE SR 11-12 with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

1

-

1799

... More
Providing & fixing MS ladder 45cms wide with 50x50x6mm size angle iron and 20mm MS bars at 25cms C/C with necessary support and angle iron of same section at braces, including fixing in ground with CC1:2:4 bed and two course of non poisonous anti-corrosive PRE SR 11-12,I.NO-6/P-44. with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

3

-

5331

... More
Geophysical investigation of site for sinking Bore well for supplying drinking water to the habitaion either through hand pump scheme mini water supply scheme or piped water supply scheme by vertical elctrical sounding by adopting vannur are schlumbergers method . including re connissance survey of geological formation. Geohidroligical investigation of existing ground water in the vicinity its quality. Quantity and acceptablity of the user. Indicating the location of site . Recommended depth of casing pipe required to seal the top un consolidated formation including extra depth of 1mt in consolidated formation for proper ceating of casing pipes. Depth of drilling corvering full depth of aquifer proposed to be tapped. probable yield and other information required for safe drinking and harnessing including transportation of instrument and accessories to work site. engaging techinical personnel and lobour required etc complete. with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

1

-

5398.05

... More
Sinking the Bore well of the 150mm dia clear using super fast hydrolic ring of capacity 250PSIG & above 900CFM& above in all strata including over burden up to 20mm. Fixing of casing pipes ,collears and cap with ncessory cutting threding and welding including transpotation of ring and supporting vehicle. Crew charges and cost of consumables etc complete including yield testing at that final depth with a minimum working of compressor for 1 hour (excluding cost of casing pipes,collars, and cap. etc ) with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. i) Up to 0.00 to 50.00 mtrs ---- As per directions of engineer in charge of work.

50

-

12967.5

... More
ii) Up to 50.00 to 100.00 mtrs ---- As per directions of engineer in charge of work.

50

-

16222.5

... More
iii) Up to 100.00 to 150.00 mtrs ---- As per directions of engineer in charge of work.

50

-

17272.5

... More
Providing & Fixing ISI mark 175mm nominal Bore medium Black ERW casing pipe B Class resistance continues welded mild steel tubes mediuam grade containing IS 1239/1990 (parts) ammendaments 1-5 etc and fitted with sockets and other end with plastick protect with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

75

-

152223.75

... More
Providing & fixing in trenches Galvanised/mild steel tools (medium grade) 50mm dia nominal doorwith all fittings (earth work in trenches to be measured & paid for seperately ) including cost of all materials. Labour charges.HOM of equipments and testing complete as per specifications ,specification No KBS 13.2.14/13.6 P-79/I.No-13.15 DHD SR 10-11. with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

40

-

20118

... More
Providing & fixing Gun metal wheel valve confirming to IS specification of approved quality and make as per directions with all lead & lift. P No 82/13.55 DHD CSR 2010-11. Gun metal wheel valve with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. 50 mm ---- As per directions of engineer in charge of work.

2

-

2280.6

... More
Providing & Fixing MS cap. with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

1

-

172.2

... More
Providing & Fixing MS collar with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- As per directions of engineer in charge of work.

25

-

3937.5

... More
Concealed Conduit System Supplying heavy gauge PVC conduit pipe19/20 mm dia 2 mm thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary .19/20mm dia 2mm thick ---- As per directions of engineer in charge of work.

680

-

41480

... More
Concealed Conduit System Supplying heavy gauge PVC conduit pipe 25 mm dia 2 mm thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 25 mm dia 2mm thick ---- As per directions of engineer in charge of work.

620

-

43400

... More
Supplying and Fixing Metal Fan Box with Round Hook. Make - Group "A" materials and as per the directions of Engineer in charge of the work. ---- As per directions of engineer in charge of work.

27

-

4401

... More
Supplying heavy gauge PVC Conduit Pipe 19/20 dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.19/20mm dia 2mm thick ---- As per directions of engineer in charge of work.

320

-

24000

... More
Supplying heavy gauge PVC Conduit Pipe 25 mm dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25 mm dia 2mm thick ---- As per directions of engineer in charge of work.

280

-

22400

... More
Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 4 Way TP &N - Group "A" materials and as per the directions of Engineer in charge of the work ---- As per directions of engineer in charge of work.

4

-

12212

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. Make - Group "A" materials and as per the directions of Engineer in charge of the work.1-3Way ---- As per directions of engineer in charge of work.

54

-

6642

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. Make - Group "A" materials and as per the directions of Engineer in charge of the work.4-5 Way ---- As per directions of engineer in charge of work.

16

-

2208

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. Make - Group "A" materials and as per the directions of Engineer in charge of the work.6 Way ---- As per directions of engineer in charge of work.

12

-

2544

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 8 Way ---- As per directions of engineer in charge of work.

42

-

10500

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 10-12 Way ---- As per directions of engineer in charge of work.

14

-

4550

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 16-18 Way ---- As per directions of engineer in charge of work.

18

-

6372

... More
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5 sq mm (Phase & Neutral) & 1x1.0 sq mm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box ---- As per directions of engineer in charge of work.

56

-

14056

... More
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5 sq mm (Phase & Neutral) & 1x1.0 sq mm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box ---- As per directions of engineer in charge of work.

82

-

29602

... More
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5 sq mm (Phase & Neutral) & 1x1.0 sq mm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box ---- As per directions of engineer in charge of work.

34

-

18428

... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sq mm Make - Group "A" materials and as per the directions of Engineer in charge of the work ---- As per directions of engineer in charge of work.

1350

-

35100

... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sq mm Make - Group "A" materials and as per the directions of Engineer in charge of the work ---- As per directions of engineer in charge of work.

3200

-

128000

... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sq mm Make - Group "A" materials and as per the directions of Engineer in charge of the work ---- As per directions of engineer in charge of work.

620

-

36580

... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sq mm Make - Group "A" materials and as per the directions of Engineer in charge of the work ---- As per directions of engineer in charge of work.

420

-

36540

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 1 to 3 Module ---- As per directions of engineer in charge of work.

54

-

8208

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 4 Module ---- As per directions of engineer in charge of work.

16

-

2800

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 6 Module ---- As per directions of engineer in charge of work.

12

-

2928

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 8 Module ---- As per directions of engineer in charge of work.

42

-

12684

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 10-12 Module ---- As per directions of engineer in charge of work.

14

-

5082

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 16-18 Module ---- As per directions of engineer in charge of work.

18

-

7254

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 6Amps One Way Switch ---- As per directions of engineer in charge of work.

306

-

26928

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 6Amps Two Way Switch ---- As per directions of engineer in charge of work.

8

-

1216

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 6Amps Three Way socket ---- As per directions of engineer in charge of work.

86

-

13932

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Make - Group "A" materials and as per the directions of Engineer in charge of the work. Stepped Fan Regulator. ---- As per directions of engineer in charge of work.

27

-

8451

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 32Amps DP Switch ---- As per directions of engineer in charge of work.

10

-

3750

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 6/16Amps Universal Socket ---- As per directions of engineer in charge of work.

10

-

2490

... More
Supplying and fixing cast Aluminium round or oblong type bulk head fitting with GI wire guard, glass cover with 15Watts 230V CFL lamp as required ---- As per directions of engineer in charge of work.

6

-

5712

... More
Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- As per directions of engineer in charge of work.

98

-

11564

... More
Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- As per directions of engineer in charge of work.

9

-

13878

... More
Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 C mm / Watt, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 �C by resistance method at 245 Volts, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, watt& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty. 48" Sweep 5 Star (1200 mm) ---- As per directions of engineer in charge of work.

27

-

79623

... More
Supplying wall mounting fan suitable to operate at single- phase 230v AC. supply. 400 mm Sweep ---- As per directions of engineer in charge of work.

1

-

2838

... More
Supplying & fixing of Surface mounting type retrofit type -LED tube ....... W comprising of LED linear source with CCT 6500 degree K, CRI> 70%. efficacy >80 lumen per watt, life> 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF > 0.95, power loss should < 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. Polycarbonate/OPAL Acrylic Casing 18W-20 W (T8) ---- As per directions of engineer in charge of work.

68

-

42296

... More
Supplying of recess mounting non integral type1 'x1' 34 -22 W LED luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI> 70%. efficacy > 100 lumen per watt, 120degree beam spread, life> 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF > 0.95, power loss should< 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 1 'x1' 34 -22 W ---- As per directions of engineer in charge of work.

22

-

63118

... More
Supplying of recess mounting non integral type2'x2' /1' x 4' 34 -36 W LED luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI> 70%. efficacy > 100 lumen per watt, 120degree beam spread, life> 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF > 0.95, power loss should< 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2' /1' x 4' 34 -36 W ---- As per directions of engineer in charge of work.

2

-

11302

... More
Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI> 70%. efficacy >80 lumen per watt, life> 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF > 0.95, power loss should < 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18W, 6500K ---- As per directions of engineer in charge of work.

32

-

13952

... More
Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall/ ceiling / Rafter / Girders ---- As per directions of engineer in charge of work.

96

-

11424

... More
Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ---- As per directions of engineer in charge of work.

27

-

4374

... More
Extra length of GI pipe of class B 19 mm dia for down rod. ---- As per directions of engineer in charge of work.

26

-

4498

... More
Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 amps. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. ---- As per directions of engineer in charge of work.

10

-

4320

... More
Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Remote Controled ---- As per directions of engineer in charge of work.

6

-

6690

... More
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A DP ---- As per directions of engineer in charge of work.

16

-

17648

... More
Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V up to 300mA sensitivity on existing wood/panel board. 16-25 A 2 pole ---- As per directions of engineer in charge of work.

4

-

10144

... More
Supplying, erecting, testing & co mmissioning of OFF- LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with all accessories complete and Excluding batteries and wiring complete. 5 KVA OFF LINE UPS ---- As per directions of engineer in charge of work.

1

-

38661

... More
Supplying, installation, testing & co mmissioning of 12Volts ..AH batteries in poly propylene container for D.G. sets. Low maintenance batteries, plate type. 150 AH capacity ---- As per directions of engineer in charge of work.

6

-

162036

... More
Supplying of .. TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 Volts with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit. 1.5 Ton capacity ---- As per directions of engineer in charge of work.

2

-

131896

... More
Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support up to 3.0 Ton split/cassette type A/C. ---- As per directions of engineer in charge of work.

2

-

9962

... More
Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tube. Split ---- As per directions of engineer in charge of work.

10

-

16310

... More
Supplying, erecting, testing and co mmissioning of voltage stabilizer suitable for 170 to 270 V input and load variation from no load to full load, with over load protection, spike suppression, operating at 00 C to 400 C. Range etc., complete. 5KVA Capacity ---- As per directions of engineer in charge of work.

2

-

9858

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.RJ45/I.O Outlet Cat-6 ---- As per directions of engineer in charge of work.

26

-

5486

... More
Supplying and drawing UTP-CAT 6E LAN cable. ---- As per directions of engineer in charge of work.

720

-

24480

... More
Supplying & Fixing of switch mounting rack with power manager & Cable manager. 18U with 650 mm depth ---- As per directions of engineer in charge of work.

1

-

20411

... More
Supplying & Fixing of Power strip ---- As per directions of engineer in charge of work.

1

-

1233

... More
Supplying fixing of Network Switches, 24 port 10/100/1000 Switch ---- As per directions of engineer in charge of work.

1

-

8241

... More
Supplying & fixing of I/O socket with back box, Single I/O ---- As per directions of engineer in charge of work.

26

-

10530

... More
Supplying & Fixing of Patch panel for LAN cabling, 24 Port 101100 patch panel ---- As per directions of engineer in charge of work.

1

-

4258

... More
Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2 Pair ---- As per directions of engineer in charge of work.

140

-

2660

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.TV/Telephone Socket ---- As per directions of engineer in charge of work.

3

-

441

... More
Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6. ---- As per directions of engineer in charge of work.

60

-

2520

... More
Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 63 A ---- As per directions of engineer in charge of work.

3

-

1116

... More
Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution). 63 A ---- As per directions of engineer in charge of work.

1

-

6391

... More
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (Icu=lcs). 100 A 25kA ---- As per directions of engineer in charge of work.

1

-

8265

... More
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A TPN ---- As per directions of engineer in charge of work.

3

-

5331

... More
Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, progra mmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. ---- As per directions of engineer in charge of work.

1

-

8316

... More
Supplying, fixing and wiring 3 Phase Digital A mmeter / Voltmeter ---- As per directions of engineer in charge of work.

1

-

1280

... More
Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound. ---- As per directions of engineer in charge of work.

3

-

1515

... More
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. ---- As per directions of engineer in charge of work.

3

-

1392

... More
Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6 mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4 x 30 x 6 mm Aluminium Strips ---- As per directions of engineer in charge of work.

1.2

-

2656.8

... More
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mm ---- As per directions of engineer in charge of work.

12

-

3300

... More
Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16SWG ---- As per directions of engineer in charge of work.

64000

-

24320

... More
Supplying PVC/GI flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely. 25 mm ---- As per directions of engineer in charge of work.

28

-

868

... More
Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6 mm Copper strip ---- As per directions of engineer in charge of work.

1.2

-

1149.6

... More
Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG Copper Wire. ---- As per directions of engineer in charge of work.

24

-

2520

... More
Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. ---- As per directions of engineer in charge of work.

4

-

16600

... More
Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975. 3.5 core 35 sq mm ---- As per directions of engineer in charge of work.

120

-

25040.4

... More
Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe/ stoneware pipe /on wall / on pole as required. 25 sq mm to 75 sq mm ---- As per directions of engineer in charge of work.

120

-

2836.8

... More
Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc. complete.(As per Civil SR KSRB 1-2, P-7). In soil (hard) ---- As per directions of engineer in charge of work.

100

-

7800

... More
Providing and laying in position 100 mm dia stone ware pipe in existing trench. ---- As per directions of engineer in charge of work.

10

-

2150

... More
Supplying and fixing LT cast Iron pot heads suitable for 1.1KV class UG cable filled with necessary bitumen/insulating compound complete with terminals, clamps, bolts, nuts and washers etc. 35 sq mm ---- As per directions of engineer in charge of work.

2

-

632

... More
Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only). 50 mm dia ---- As per directions of engineer in charge of work.

2

-

384

... More
Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 35 sq mm Long Barrel ---- As per directions of engineer in charge of work.

16

-

512

... More
Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT > 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire > IK08. Power Factor >0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40 mm to 50 mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency>1301m/w, nominal CRI >75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 70 W ---- As per directions of engineer in charge of work.

4

-

23820

... More
Supplying and Fixing of........ mm dia class A GI pipe bracket up to 2 Mtrs long bent at suitable angle and fixing to this bracket 1x40/2x40 watts fluorescent tube street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires. Using 25 mm dia G.I.Pipe ---- As per directions of engineer in charge of work.

4

-

3348

... More
Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments 2 HP, Size 65x50 Head 13M, Discharge 462 LPM ---- As per directions of engineer in charge of work.

1

-

15425

... More
Providing,supplying to work site, Submersible Pump Set of 150mm dia 3.00 HP - 300 LPM @ 26 m = 2 STG Outlet Dia - 2.50” suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. ---- As per directions of engineer in charge of work.

1

-

25865

... More
Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990. 3C x 2.5 sq mm ---- As per directions of engineer in charge of work.

180

-

20340

... More
Providing and fixing to wall, ceiling and floor high density polyethylene pipes 6.00 kgf/sq.cm working pressure of outside diameter raising mains & exposed distribution pipes with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor,, including cost of all materials, labour charges, HOM and testing complete as per specifications. 40mm dia. ---- As per directions of engineer in charge of work.

120

-

31440

... More
Supplying push butTon operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 volts 1/3 phase motor upto 5 HP. ---- As per directions of engineer in charge of work.

2

-

2980

... More
Supplying and fixing single phase preventer using necessary wires over an existing panel board suitable for motor up to 20 HP capacities. ---- As per directions of engineer in charge of work.

1

-

805

... More
Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machineries like induction motor. ---- As per directions of engineer in charge of work.

2

-

864

... More
Fixing a shunt capacitor of ... KVAR capacity with necessary clamps, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor. 6 to 10 KVAR ---- As per directions of engineer in charge of work.

2

-

412

... More
Supply and fixing polished wood board made of not less than 15 mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws. 12" x 12" x 2" ---- As per directions of engineer in charge of work.

2

-

324

... More
Supplying, fixing and wiring 0 to 600Volts 96x96 mm AC Voltmeter on existing panel/wood board. ---- As per directions of engineer in charge of work.

1

-

407

... More
Supplying, fixing and wiring 0 to 30amps Direct Reading AC analog type A mmeter ---- As per directions of engineer in charge of work.

1

-

418

... More
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. ---- As per directions of engineer in charge of work.

3

-

1392

... More
Supplying, installation and erection of Gate valve of 50 mm dia. ---- As per directions of engineer in charge of work.

1

-

1688

... More
Supplying, installation and erection of Non Return valve of 50 mm dia. ---- As per directions of engineer in charge of work.

1

-

1275

... More
Supplying, installation and erection of Borewell cap and clamp set. ---- As per directions of engineer in charge of work.

1

-

1800

... More
Supplying, installation, testing and co mmissioning of solar hot water heater comprising of high quality Evacuated Glass Tube (EGT) with absorber coating collector of size 58 x 1800 mm. Inner tank Material-Stainless steel 304-L Grade with Aluminium Stucco cladding made of High quality PUF insulation to minimizes heat loss and hold water Temperature upto 72 Hrs...with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. Fitted with Sacrificial Anode, 200 Liter capacity- 20 nos Tubes - group "A" materials. And as per the directions of engineer incharge of the work. ---- As per directions of engineer in charge of work.

1

-

41109

... More
Providing and fixing chlorinated poly vinyl chloride (CPVC ) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all C P V C plain and brass threaded fittings, including fixing the pipe with clamp at 1.00 mtrs spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete ( external work) a) for 40mm nominal OD Pipe ---- As per directions of engineer in charge of work.

20

-

10680

... More
Providing and fixing chlorinated poly vinyl chloride (CPVC ) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all C P V C plain and brass threaded fittings, including fixing the pipe with clamp at 1.00 mtrs spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete ( external work) a) for 25mm diaMake- group "A" materials. And as per the directions of engineer incharge of the work. ---- As per directions of engineer in charge of work.

20

-

6320

... More
Providing and fixing chlorinated poly vinyl chloride (CPVC ) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all C P V C plain and brass threaded fittings, including fixing the pipe with clamp at 1.00 mtrs spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete ( external work) a) for 20mm nominal OD Pipe Make- group "A" materials. And as per the directions of engineer incharge of the work. ---- As per directions of engineer in charge of work.

20

-

4780

... More
Providing and fixing in position brass Gate Valve with C.I. wheel of app. Quality (Screw End) 40mm nominal bore including cost of all materials, labour and HOM of equipments with all leed complete as per specifications. a) for 40mm dia nominal ---- As per directions of engineer in charge of work.

2

-

3000

... More
Providing and fixing in position brass Gate Valve with C.I. wheel of app. Quality (Screw End) 40mm nominal bore including cost of all materials, labour and HOM of equipments with all leed complete as per pecifications. a) for 25 mm dia nominal Make- group "A" materials. And as per the directions of engineer incharge of the work. ---- As per directions of engineer in charge of work.

2

-

2338

... More
Supplying & fixing M.S rectangular pole made of 2 equal angles 65 x 65 x 6 mm welded together & fixed in C.C (1:2:4) with 2 nos 16 mm dia MS . Hold fast rods each of length 25cms. Including cost of all materials cutting, bending scaffolding wherever neccessary, nicely finishing the welded joints with all lead lifts and as per the directions of the engineer-in-charge of the work and including providing 2 coats of approved quality paint over one coat of shop painting ( excluding cost of earthwork and concrete) including cost of materials, labour, HOM complete as per specifications. ---- As per directions of engineer in charge of work.

22

-

18876

... More
Providing Chain link fencing 50 mm size of 8 gauage properly streched between rectangular poles and fixed with sutable bolt & nuts, the free ends shall be welded to the pole & black pipe at top & bottom as required including cost of all materials, labour,lead and lifts and as per the directions of engineer-in-charge of the work including two coats of approved quality paint over one coat of shop paint, including cost of materials, labour, HOM complete as per specifications. ---- As per directions of engineer in charge of work.

32

-

22880

... More
KSRB 4-1.6 : Providing & laying in position Plain cement concrete of Mix 1:2:4 with OPC@240 kgs, with 20mm and down size graded granite metal coarse aggregates @ 0.878 cum and fine aggregates @ 0,53 cum, machine mixed, concrete laid in layes not exeeding 15 cms. thick, well compacted, in foundation, plinth and cills, including cost of all materials, labour, HOM curing complete as per specifications. ---- As per directions of engineer in charge of work.

0.5

-

3011

... More
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mm ---- As per directions of engineer in charge of work.

36

-

9180

... More
20mm Nominal size course aggregates ---- As per directions of engineer in charge of work.

3.8

-

5130

... More
KSRB 7.9 : Providing and fixing MS grill work using MS falta or MS Square rods or combination of MS flats and square rods as per approved design drawing including cutting steel sections and welding the same to required pattern with a coat of red lead primer coat of materials, fixtures, labour and HOM complete as per specification. ---- As per directions of engineer in charge of work.

48

-

6288

... More
Distribution Transformer - 3 Phase, 11kV/433V - Amorphous Core with Oil as per IS-1180 (Part-1): 2014 OPEN BUSHING TYPE 100 kVA, Aluminium Wdg, Star 2 (5 Star) ---- As per directions of engineer in charge of work.

1

-

103100

... More
LT Distribution Box for 100 kVA DTC with MCCB's (Sheet Metal) (Dwg No. BESCOM/GM/QS&S/58 Dtd 24.11.2018) ---- As per directions of engineer in charge of work.

1

-

22809

... More
LT Protection kit (Dwg No. BESCOM/GM/QS&S/10 Dtd 24.11.2018 ---- As per directions of engineer in charge of work.

1

-

1915

... More
11 kV, HG Fuse Unit with Solid Core Insulator (Dwg No. BESCOM/GM/QS&S/21 Dtd 24.11.2018) ---- As per directions of engineer in charge of work.

1

-

18418

... More
11 kV, 200 Amps Single Break GOS (Dwg No. BESCOM/GM/QS&S/23 Dtd 24.11.2018) ---- As per directions of engineer in charge of work.

1

-

9125

... More
DOLO Cutouts as per IS-9385, Part-1 to 3, 11kV DOLO Cutouts Conventional to Erstwhile KEB Specification (Dwg No. BESCOM/GM/QS&S/20 Dtd 24.11.2018) ---- As per directions of engineer in charge of work.

1

-

5672

... More
RCC Pole - 9 Mtr Long, 150 Kg WL Sq Section (Dwg No. BESCOM/GM/QS&S/51 Dtd 24.11.2018) as per IS-785 ---- As per directions of engineer in charge of work.

3

-

24678

... More
Cross Arms (MS & GI) as per IS-1977 11kV Horizontal X Arms - Galvanised Iron (GI) ---- As per directions of engineer in charge of work.

3

-

1515

... More
Cross Arms (MS & GI) as per IS-1977 11kV Special 3 Pin X Arm - MS (Dwg No. BESCOM/GM/QS&S/03 Dtd 24.11.2018) ---- As per directions of engineer in charge of work.

1

-

921

... More
HT ST Support 50x6mm Flat - GI ---- As per directions of engineer in charge of work.

4

-

500

... More
11kV, 5KN Composite/Polymeric Pin Insulator (24mm dia FRP Rod) ---- As per directions of engineer in charge of work.

15

-

3315

... More
11kV, 45kN Polymeric Insulator ---- As per directions of engineer in charge of work.

6

-

1212

... More
Guy set complete with No.15 strain insulator & Cocreting matrials ---- As per directions of engineer in charge of work.

2

-

1504

... More
Labour charges for fixing of Guy set complete with No.15 strain insulator & Cocreting matrials ---- As per directions of engineer in charge of work.

2

-

708

... More
ACSR conductor as per IS-398 (Part - 2/1996), Rabbit ACSR (6/3.35 mm Al + 1/3.35 mm St), Std Wt : 214 kgs/km ---- As per directions of engineer in charge of work.

0.4

-

24606

... More
PG clamps for Rabbit to Rabbit conductor ---- As per directions of engineer in charge of work.

5

-

580

... More
Spiral Earth Electrode ---- As per directions of engineer in charge of work.

5

-

1240

... More
EG Stirrups (MS) with GI wire lacing ---- As per directions of engineer in charge of work.

5

-

1435

... More
Caution/Danger Board ---- As per directions of engineer in charge of work.

2

-

292

... More
Anti climbing device GI Barbed wire (12mtrs/Kg) ---- As per directions of engineer in charge of work.

12

-

1116

... More
Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 Amps three phase 4 wire whole current class-1 Accuracy Energy Meter. ---- As per directions of engineer in charge of work.

1

-

5125



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.