Karnataka State Police Housing And Infrastructure Development Corporation Limited Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Karnataka State Police Housing And Infrastructure Development Corporation Limited - KSPHCL Tender

Civil And Construction
Opening Date18 Jun 2022
Closing Date28 Jun 2022
Tender Amount₹ 3,36,87,065 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work, including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. In ordinary/soft rock without blasting ---- as per directions of engineer in charge of work.

280.68

-

80162.21

... More
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm and down size graded crushed coarse aggregates, including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Foundation & floor bed ---- as per directions of engineer in charge of work.

131.39

-

740014.76

... More
Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (including cost of providing & removing formwork as per Design & Drawing) M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates, including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Column footing ---- as per directions of engineer in charge of work.

111.73

-

789478.59

... More
Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(including cost of providing & removing formwork as per Design & Drawing),including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Column- Ground Floor ---- as per directions of engineer in charge of work.

35.59

-

265999.66

... More
Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(including cost of providing & removing formwork as per Design & Drawing),including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Column-First Floor ---- as per directions of engineer in charge of work.

7.43

-

56036.69

... More
Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(including cost of providing & removing formwork as per Design & Drawing),including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Column-Second Floor ---- as per directions of engineer in charge of work.

10.18

-

77468.78

... More
Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand), including cost of all materials, labour, HOM of machinery, curing complete as per specifications.,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

55.71

-

308037.3

... More
Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand), including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

38.23

-

217647.21

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, with all lead and lift,,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

250.24

-

53601.41

... More
Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work,,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

658

-

277741.8

... More
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.,(including cost of providing & removing formwork as per Design & Drawing),including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Plinth beam. ---- as per directions of engineer in charge of work.

25.42

-

175327.84

... More
Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete,,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor ---- as per directions of engineer in charge of work.

108.34

-

767632.24

... More
Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete,,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor ---- as per directions of engineer in charge of work.

59.55

-

426154.69

... More
Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete,,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Second Floor ---- as per directions of engineer in charge of work.

80.03

-

578385.61

... More
Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete, ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor ---- as per directions of engineer in charge of work.

103.95

-

95504.06

... More
Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete, ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor ---- as per directions of engineer in charge of work.

64.89

-

60214.03

... More
Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete, ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Second Floor ---- as per directions of engineer in charge of work.

64.89

-

60809.72

... More
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.,(including cost of providing & removing formwork as per Design & Drawing),including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Mix 1:3:6 (M10) Using 20 mm and down size graded crushed coarse aggregates For coping & window cills. Ground Floor ---- as per directions of engineer in charge of work.

6.91

-

45145.93

... More
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.,(including cost of providing & removing formwork as per Design & Drawing),including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Mix 1:3:6 (M10) Using 20 mm and down size graded crushed coarse aggregates For coping & window cills. First Floor ---- as per directions of engineer in charge of work.

1.97

-

12993.41

... More
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.,(including cost of providing & removing formwork as per Design & Drawing),including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Mix 1:3:6 (M10) Using 20 mm and down size graded crushed coarse aggregates For coping & window cills. Second Floor ---- as per directions of engineer in charge of work.

3.49

-

23235.93

... More
Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.,(including cost of providing & removing formwork as per Design & Drawing),including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Staircase/lintel/wall shelves/Roofbeam/Roofslab-Ground Floor ---- as per directions of engineer in charge of work.

114.32

-

932103.55

... More
Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.,(including cost of providing & removing formwork as per Design & Drawing),including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Staircase/lintel/wall shelves/Roofbeam/Roofslab Works-First Floor ---- as per directions of engineer in charge of work.

78.02

-

641434.41

... More
Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.,(including cost of providing & removing formwork as per Design & Drawing),including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Staircase/lintel/wall shelves/Roofbeam/Roofslab Works-Second Floor ---- as per directions of engineer in charge of work.

81.7

-

677239.9

... More
Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.,(including cost of providing & removing formwork as per Design & Drawing),including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Plain Chejja Ground Floor ---- as per directions of engineer in charge of work.

4.28

-

42166.99

... More
Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.,(including cost of providing & removing formwork as per Design & Drawing),including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Plain Chejja First Floor ---- as per directions of engineer in charge of work.

2.76

-

27379.31

... More
Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.,(including cost of providing & removing formwork as per Design & Drawing),including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Plain Chejja Second Floor ---- as per directions of engineer in charge of work.

2.76

-

27566.85

... More
Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

552.21

-

431966.27

... More
Providing and laying in position plain cement concrete of mix M20 with OPC cement @ 300kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregtes @ 0.43cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, plinth and cills, including cost of all materials, labour, HOM of machinery, curing complete as per specifications.,,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Screed concrete with WPC over roof slab. Second Floor ---- as per directions of engineer in charge of work.

40.92

-

242800.87

... More
Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Outside walls Ground Floor ---- as per directions of engineer in charge of work.

1406.73

-

485954.88

... More
Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications,,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Outside walls First Floor ---- as per directions of engineer in charge of work.

383.27

-

133722.9

... More
Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications,,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Outside walls Second Floor ---- as per directions of engineer in charge of work.

562.08

-

198054.51

... More
Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications, including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Inside walls Ground Floor ---- as per directions of engineer in charge of work.

837.3

-

177591.33

... More
Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications, including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Inside walls First Floor ---- as per directions of engineer in charge of work.

543.91

-

116516.4

... More
Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications, including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Inside walls Second Floor ---- as per directions of engineer in charge of work.

578.12

-

125070.48

... More
Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications, including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Ceiling Ground Floor ---- as per directions of engineer in charge of work.

451.4

-

103325.46

... More
Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications, including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Ceiling First Floor ---- as per directions of engineer in charge of work.

300.03

-

69363.94

... More
Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications, including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Ceiling Second Floor ---- as per directions of engineer in charge of work.

317.69

-

74174.26

... More
Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications, including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor ---- as per directions of engineer in charge of work.

94.9

-

23316.93

... More
Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications, including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor ---- as per directions of engineer in charge of work.

72.6

-

18016.42

... More
Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications, including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Second Floor ---- as per directions of engineer in charge of work.

72.6

-

18016.42

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications, including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor ---- as per directions of engineer in charge of work.

1296.97

-

113030.94

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications, including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor ---- as per directions of engineer in charge of work.

843.94

-

73549.37

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications, including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Second Floor ---- as per directions of engineer in charge of work.

895.81

-

78069.84

... More
Providing and fixing for flooring 20mm thick sadarhalli grey granite in CM 1:4 proportion, cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, groves in joints including cost of including cost of all materials, mortar, labour, curing etc., complete as per specification. minimum width of 1200mm (gang saw water cut), including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor ---- as per directions of engineer in charge of work.

414.3

-

890040.69

... More
Providing and fixing for flooring 20mm thick sadarhalli grey granite in CM 1:4 proportion, cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, groves in joints including cost of including cost of all materials, mortar, labour, curing etc., complete as per specification. minimum width of 1200mm (gang saw water cut), including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor ---- as per directions of engineer in charge of work.

258.69

-

556286.98

... More
Providing and fixing for flooring 20mm thick sadarhalli grey granite in CM 1:4 proportion, cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, groves in joints including cost of including cost of all materials, mortar, labour, curing etc., complete as per specification. minimum width of 1200mm (gang saw water cut), including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Second Floor ---- as per directions of engineer in charge of work.

258.69

-

556830.22

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor ---- as per directions of engineer in charge of work.

22.07

-

17913.12

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor ---- as per directions of engineer in charge of work.

19.37

-

15878.94

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Second Floor ---- as per directions of engineer in charge of work.

19.37

-

16036.04

... More
Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor ---- as per directions of engineer in charge of work.

110.15

-

239989.31

... More
Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor ---- as per directions of engineer in charge of work.

87.85

-

193317.44

... More
Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Second Floor ---- as per directions of engineer in charge of work.

87.85

-

195230.81

... More
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, Lakared, River Pink, Orissa Blue or equivalent.,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor ---- as per directions of engineer in charge of work.

103.67

-

313606.93

... More
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, Lakared, River Pink, Orissa Blue or equivalent.,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor ---- as per directions of engineer in charge of work.

56.05

-

171249.56

... More
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, Lakared, River Pink, Orissa Blue or equivalent.,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Second Floor ---- as per directions of engineer in charge of work.

56.05

-

172945.08

... More
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.Ground Floor ---- as per directions of engineer in charge of work.

2655.92

-

476870.44

... More
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.First Floor ---- as per directions of engineer in charge of work.

1419.05

-

254790.43

... More
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.Second Floor ---- as per directions of engineer in charge of work.

1419.05

-

254790.43

... More
Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves ( excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor ---- as per directions of engineer in charge of work.

0.54

-

51252.83

... More
Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves ( excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor ---- as per directions of engineer in charge of work.

0.36

-

34168.55

... More
Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves ( excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Second Floor ---- as per directions of engineer in charge of work.

0.41

-

38914.19

... More
Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead, including cost of materials, labour charges, complete as per specifications..,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor ---- as per directions of engineer in charge of work.

10

-

15592.5

... More
Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead, including cost of materials, labour charges, complete as per specifications..,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor ---- as per directions of engineer in charge of work.

7

-

10914.75

... More
Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead, including cost of materials, labour charges, complete as per specifications..,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Second Floor ---- as per directions of engineer in charge of work.

8

-

12474

... More
Providing and fixing in position fully panelled Honne wood shutters for doors with , stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures ), including cost of materials, labour charges, complete as per specifications.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor ---- as per directions of engineer in charge of work.

21.59

-

110309.79

... More
Providing and fixing in position fully panelled Honne wood shutters for doors with , stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures ), including cost of materials, labour charges, complete as per specifications..,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor ---- as per directions of engineer in charge of work.

14.66

-

75651.32

... More
Providing and fixing in position fully panelled Honne wood shutters for doors with , stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures ), including cost of materials, labour charges, complete as per specifications..,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Second Floor ---- as per directions of engineer in charge of work.

16.66

-

86823.42

... More
Providing and fixing Mosquito mesh shutters made out of stainless steel mosquito proof mesh with 95% and above visibility which is fixed to the powder coated aluminium frame of size 2 1/2 x 1 1/2 all round and 32mm thick of appoved shade. The work including fixing the shutters with necessary accessories, to complete as per specification including the labour charges for fixing the shutter to the existing frames.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

2.36

-

7186.2

... More
Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass,standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size – 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.Ground Floor ---- as per directions of engineer in charge of work.

69.57

-

528871.14

... More
Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass,standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size – 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.First Floor ---- as per directions of engineer in charge of work.

53.1

-

403666.2

... More
Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass,standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size – 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.Second Floor ---- as per directions of engineer in charge of work.

53.1

-

403666.2

... More
Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.Ground Floor ---- as per directions of engineer in charge of work.

61.95

-

30897.56

... More
Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification,,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.First Floor ---- as per directions of engineer in charge of work.

57

-

28428.75

... More
Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification,,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Second Floor ---- as per directions of engineer in charge of work.

57

-

28428.75

... More
Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.-with both side prelam-Ground Floor ---- as per directions of engineer in charge of work.

18.79

-

75031.29

... More
Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.-with both side prelam-First Floor ---- as per directions of engineer in charge of work.

17.22

-

68762.04

... More
Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.-with both side prelam-Second Floor ---- as per directions of engineer in charge of work.

17.22

-

68762.04

... More
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m� over and including priming coat of exterior primer applied @ 2.20 kg/10 m�) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor ---- as per directions of engineer in charge of work.

1513.62

-

216144.94

... More
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m� over and including priming coat of exterior primer applied @ 2.20 kg/10 m�) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor ---- as per directions of engineer in charge of work.

452.33

-

65239.56

... More
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m� over and including priming coat of exterior primer applied @ 2.20 kg/10 m�) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Second Floor ---- as per directions of engineer in charge of work.

452.33

-

65886.39

... More
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications,,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.For Ceiling & Inside walls -Ground Floor ---- as per directions of engineer in charge of work.

1296.97

-

162056.4

... More
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications,,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.For Ceiling & Inside walls -First Floor ---- as per directions of engineer in charge of work.

843.94

-

105450.3

... More
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications,,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.For Ceiling & Inside walls -Second Floor ---- as per directions of engineer in charge of work.

895.81

-

111931.46

... More
Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately),including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor ---- as per directions of engineer in charge of work.

35184.98

-

3916088.27

... More
Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately),including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor ---- as per directions of engineer in charge of work.

9503

-

1068232.23

... More
Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately),including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Second Floor ---- as per directions of engineer in charge of work.

2290

-

259983.7

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications, ,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor ---- as per directions of engineer in charge of work.

51.03

-

6965.6

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications, ,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor ---- as per directions of engineer in charge of work.

35.44

-

4885.76

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications, ,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Second Floor ---- as per directions of engineer in charge of work.

40.4

-

5624.89

... More
Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.: 10mm to 15 mm wide and 8 mm deep groove. ---- as per directions of engineer in charge of work.

2509.6

-

105403.2

... More
Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

7750

-

9765

... More
Planting of trees by the road side (Avenue trees) in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, planting the saplings, backfilling the trench, watering, fixing the tree guard and maintaining the plants for one year complete as per specifications.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

12

-

504

... More
Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.,,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

748.18

-

74630.96

... More
Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete,,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

414.45

-

117061.4

... More
Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :New work (two coats) including a coat of approved steel primer but excluding a coat of mordant solution including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications ,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.For metal surface - Ground Floor ---- as per directions of engineer in charge of work.

99.51

-

10448.55

... More
Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :New work (two coats) including a coat of approved steel primer but excluding a coat of mordant solution including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications ,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.For metal surface - First Floor ---- as per directions of engineer in charge of work.

49.19

-

5216.6

... More
Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :New work (two coats) including a coat of approved steel primer but excluding a coat of mordant solution including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications ,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.For metal surface - Second Floor ---- as per directions of engineer in charge of work.

49.19

-

5268.25

... More
Providing and conducting SBC soil test of the proposed site by collecting the sample at required depth including excavating the trial pit of required depth and submitting the SBC test report from the approved NABL lab as per direction of Engineer In-charge, including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

2

-

10000

... More
Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

364.5

-

141990.98

... More
Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead and lift, ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

364.5

-

46692.45

... More
Providing and fixing Chlorinated Polyvinyl Chloride(CPVC)pipes, having thermal stability for hot & cold watersupply,including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. CPVC pipe - 25mm ---- as per directions of engineer in charge of work.

210

-

104958

... More
Providing and fixing Chlorinated Polyvinyl Chloride(CPVC)pipes, having thermal stability for hot & cold watersupply,including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. External work, including cutting chases and making good the walls etc.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. CPVC pipe - 32mm ---- as per directions of engineer in charge of work.

338

-

127054.2

... More
Providing and fixing Chlorinated Polyvinyl Chloride(CPVC)pipes, having thermal stability for hot & cold watersupply,including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. External work, including cutting chases and making good the walls etc.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. CPVC pipe - 40mm ---- as per directions of engineer in charge of work.

300

-

147735

... More
Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges,handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.,,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.(PVC pipe of 6Kgs/Sqm -75mm dia ) ---- as per directions of engineer in charge of work.

118

-

26019

... More
Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges,handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.,,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.(PVC pipe of 6Kgs/Sqm -110mm dia ) ---- as per directions of engineer in charge of work.

450

-

186165

... More
Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges,handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.,,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.(PVC pipe of 6Kgs/Sqm -160mm dia ) ---- as per directions of engineer in charge of work.

700

-

440265

... More
Providing and fixing in position Pillar cock of Jaquar/Hindware/Parry ware of approved quality 20mm nominal bore including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

12

-

15000

... More
Providing and fixing in position Short body cock/tap of Jaquar/Hindware/Parry ware of approved quality 20mm nominal bore including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

23

-

28750

... More
Providing and fixing in position Long body cock/tap of Jaquar/Hindware/Parry ware of approved quality 20mm nominal bore including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

31

-

41850

... More
Providing and placing on terrace (at all floor levels ) polyethylene water storagetank, IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittinigs and the base support for tank., including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

6000

-

50400

... More
Constructing brick masonry inspection chamber for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C I cover withframe (light duty) internal dimensions, total weight of cover with frame to be not less than 38 kg ( weight of cover 23kg and weight of frame 15 kg) R. C. C. top slab with cement concrete M 15 with 20mm and downsize granite metal, foundation concrete M 5 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications. 600x600mm and 450mm depth (clear inside dimension) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1 5, C I cover withframe (light duty) 600x600mm,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

26

-

231777

... More
Constructing brick masonry inspection chamber for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C I cover withframe (light duty) internal dimensions, total weight of cover with frame to be not less than 38 kg ( weight of cover 23kg and weight of frame 15 kg) R. C. C. top slab with cement concrete M 15 with 20mm and downsize granite metal, foundation concrete M 5 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications.Specification No. KBS 450x450mm and 450mm depth (clear inside dimension) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1 5, C I cover withframe (light duty) 450x450mm, ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

26

-

144690

... More
Constructing brick masonry circular type manhole 0.91 m internal dia at bottom 0.91m deep and 0.56m dia at top with table moulded non-modular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ),,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

5

-

77626.5

... More
Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. 32mm dia ---- as per directions of engineer in charge of work.

10

-

6058.5

... More
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests, ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

21

-

93624.3

... More
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid, ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

20

-

105105

... More
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

20

-

18249

... More
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

21

-

8379

... More
Providing 10cms dia PVC cowl with cap of approved 1 st quality and make conforming to ISI specifications and fixing in position as directed ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

6

-

1442.7

... More
Providing and fixing 7.5 cms to 15.00 cms dia NP grating 100 mm dia.. ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

12

-

1890

... More
Providing stoneware gully trap of approved quality and make fixing in M-15 and plastering with CM 1:3 wherever necessary. ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. 15cms x 10cms ---- as per directions of engineer in charge of work.

5

-

1470

... More
Providing NP/CP waste unions conforming to ISI specifications and fixing them in position as per directions, ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. for 32mm dia. ---- as per directions of engineer in charge of work.

6

-

756

... More
Wall bores in size stone masonry. including cost of materials, labour, HOM complete as per specifications. upto 45 em thick..,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

25

-

7953.75

... More
Wall bores in Brick masonry upto 45 em thick. including cost of materials, labour, HOM complete as per specifications.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

35

-

4630.5

... More
Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. For Medium Duty GI pipe of 50mm dia ---- as per directions of engineer in charge of work.

180

-

90531

... More
Providing and fixing in position Health faucet complete set of Jaquar/Hindware/Parry ware of approved quality 20mm nominal bore including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

20

-

27000

... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15mm C.P. brass pillar tap,,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

24

-

54331.2

... More
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors: 100mminletand75mmoutlet ,• Hubless centrifugally cast(spun) iron epoxy coated inside & outside as per IS:15905,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

84

-

41895

... More
Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. (including cost of providing & removing formwork as per Design & Drawing) For Sump bottom slab & side RCC Walls ---- as per directions of engineer in charge of work.

32.7

-

224638.54

... More
Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. (including cost of providing & removing formwork as per Design & Drawing) For Sump Roofslab ---- as per directions of engineer in charge of work.

5.62

-

44299.99

... More
Providing 20 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. For Sump ---- as per directions of engineer in charge of work.

192.2

-

76687.8

... More
Providing and fixing MS inspection door of size 60 cms x 60 cms, including MS frame made of 50x50x6mm angle, shutters made of 3mm thick MS sheets, with hinges, locking arrangements at top etc. including painting with anticorrosive approved paint etc. complete including all lead and lifts etc.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

1

-

2216.55

... More
Providing and fixing MS ladder between landings, 45 cms wide using angle iron of specified sizes, 20mm MS bars at 25 cms. centre to centre, with necessary supports of same angle iron etc. as directed, including hand railing on both sides with 25mm dia. GI pipes with angle iron props at 2 mtrs. intervals and 0.5M heigh, including fixing in ground with CC 1:2:4 and two coats of anticorrosive bituminous paint etc. with all lead and lifts etc. complete with: MS angle of 65 x 65 x 10mm ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

4.5

-

22429.58

... More
Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

228.52

-

288415.09

... More
Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. (including cost of providing & removing formwork as per Design & Drawing)For RCC head walls to the CD work. ---- as per directions of engineer in charge of work.

26.71

-

179994.15

... More
Preparation and surface treatment of formation by removing mud and slurry, watering to the extent needed to maintain the desired moisture content, trimming to the required line, grade, profile and rolling with 8-10 t smooth wheeled roller, complete as per clause 310. ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

562.5

-

1771.88

... More
Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. For Grading -V Material ---- as per directions of engineer in charge of work.

253.13

-

623800.92

... More
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

84.38

-

212106.01

... More
Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, , primer, sealant , curing of concrete slabs for 14days, and water finishing to lines and grade as per drawing and technical specification clause 1501 ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

67.5

-

484572.38

... More
Providing groove cutting for width of 5mm to 1Omm and depth 80mm-100mm including cost of cutting machine, generator & HOM, including cost of blade, coolant etc., including cleaning of groove & providing sand and hot bitumen fillars, and filler metal etc. , including cost of conveyance of all materials, labour, lead and lift charges and all other incidental charges as per drawing and as per specifications.-for concrete pavement ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

1275

-

180731.25

... More
Providing and laying heavy duty cobble stones 75mm thick interlock pavers, using cement and course sand for manufacture of blocks of approved size, shape and colour with a minimum compressive strength of 281 kg per m2 over 50mm thick sand bed ( average thickness ) and compacting with plate vibrator having 3 tons compaction force thereby forcing part of sand underneath to come up in between joints, final compaction of paver surface joints into its final level, including cost of materials, labour and Usage charges of machinery complete as per specifications. ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

675

-

811518.75

... More
Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped,probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

2

-

10796.1

... More
Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: Up to 0.00 to 50.00 mtrs ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

100

-

25935

... More
Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: Up to 50.00 to 100.00 mtrs ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

100

-

32445

... More
Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: Up to 100.00 to 150.00 mtrs ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

40

-

13818

... More
Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

40

-

81186

... More
Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For Medium Duty GI pipe: 50mm dia ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

150

-

75442.5

... More
Providing and fixing gun metal non- return valve of approved quality (screwed end) : 50 mm nominal bore Horizontal ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

2

-

2280.6

... More
Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. ---- as per directions of engineer in charge of work.

6

-

6841.8

... More
Providing and laying at site of work MS casing caps as per IS 1239 (partII) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge ---- as per directions of engineer in charge of work.

1

-

172.2

... More
Concealed Conduit System Supplying heavy gauge PVC conduit pipe19/20 mm dia 2 mm thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary .19/20mm dia 2mm thick using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

1230

-

75030

... More
Concealed Conduit System Supplying heavy gauge PVC conduit pipe 25 mm dia 2 mm thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 25 mm dia 2mm thick using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

1440

-

100800

... More
Supplying and Fixing Metal Fan Box with Round Hook. Make - Group "A" materials and as per the directions of Engineer in charge of the work using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

66

-

10758

... More
Supplying heavy gauge PVC Conduit Pipe 19/20 dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.19/20mm dia 2mm thick using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

930

-

69750

... More
Supplying heavy gauge PVC Conduit Pipe 25 mm dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25 mm dia 2mm thick using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

660

-

52800

... More
Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 1) 8Way SP &N - Group "A" materials and as per the directions of Engineer in charge of the work ---- as per directions of engineer in charge of work.

12

-

20340

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. Make - Group "A" materials and as per the directions of Engineer in charge of the work.1-3Way ---- as per directions of engineer in charge of work.

84

-

10332

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. Make - Group "A" materials and as per the directions of Engineer in charge of the work.4-5 Way ---- as per directions of engineer in charge of work.

36

-

4968

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. Make - Group "A" materials and as per the directions of Engineer in charge of the work.6 Way ---- as per directions of engineer in charge of work.

18

-

3816

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 8 Way ---- as per directions of engineer in charge of work.

132

-

33000

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 10-12 Way ---- as per directions of engineer in charge of work.

18

-

5850

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 16-18 Way ---- as per directions of engineer in charge of work.

18

-

6372

... More
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5 sq mm (Phase & Neutral) & 1x1.0 sq mm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

138

-

34638

... More
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5 sq mm (Phase & Neutral) & 1x1.0 sq mm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

180

-

64980

... More
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5 sq mm (Phase & Neutral) & 1x1.0 sq mm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

108

-

58536

... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sq mm Make - Group "A" materials and as per the directions of Engineer in charge of the work ---- as per directions of engineer in charge of work.

2700

-

70200

... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sq mm Make - Group "A" materials and as per the directions of Engineer in charge of the work ---- as per directions of engineer in charge of work.

5700

-

228000

... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sq mm Make - Group "A" materials and as per the directions of Engineer in charge of the work ---- as per directions of engineer in charge of work.

2400

-

141600

... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sq mm Make - Group "A" materials and as per the directions of Engineer in charge of the work ---- as per directions of engineer in charge of work.

1200

-

104400

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 1 to 3 Module ---- as per directions of engineer in charge of work.

84

-

12768

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 4 Module ---- as per directions of engineer in charge of work.

36

-

6300

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 6 Module ---- as per directions of engineer in charge of work.

18

-

4392

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 8 Module ---- as per directions of engineer in charge of work.

132

-

39864

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 10-12 Module ---- as per directions of engineer in charge of work.

18

-

6534

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 16-18 Module ---- as per directions of engineer in charge of work.

18

-

7254

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 6Amps One Way Switch ---- as per directions of engineer in charge of work.

618

-

54384

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 6Amps Two Way Switch ---- as per directions of engineer in charge of work.

6

-

1050

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 6Amps Three Way socket ---- as per directions of engineer in charge of work.

228

-

36936

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Make - Group "A" materials and as per the directions of Engineer in charge of the work. Stepped Fan Regulator. ---- as per directions of engineer in charge of work.

66

-

20658

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 32Amps DP Switch ---- as per directions of engineer in charge of work.

36

-

13500

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 6/16Amps Universal Socket ---- as per directions of engineer in charge of work.

36

-

8964

... More
Supplying & Fixing of 70-150 Watts lamp holder 2 Pin using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

258

-

30444

... More
Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

24

-

37008

... More
Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 C mm / Watt, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 �C by resistance method at 245 Volts, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, watt& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty. 48" Sweep 5 Star (1200 mm) using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

66

-

194634

... More
Supplying & fixing retrofit type-PL- LED Lamp ...... W LED linear source with CCT 6500 degree K, CRI> 70%. efficacy >80 lumen per W, life> 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF > 0.95, power loss should < 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to275 V. Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.18W-20 W using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

165

-

114015

... More
Supplying of recess mounting non integral type1 'x1' 34 -22 W LED luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI> 70%. efficacy > 100 lumen per watt, 120degree beam spread, life> 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF > 0.95, power loss should< 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 1 'x1' 34 -22 W using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

30

-

86070

... More
Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI> 70%. efficacy >80 lumen per watt, life> 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF > 0.95, power loss should < 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18W, 6500K using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

93

-

40548

... More
Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall/ ceiling / Rafter / Girders using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

195

-

23205

... More
Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

66

-

10692

... More
Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 amps. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

24

-

10368

... More
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A DP using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

36

-

39708

... More
Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V up to 300mA sensitivity on existing wood/panel board. 16-25 A 2 pole using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

12

-

30432

... More
Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 63 A using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

3

-

1116

... More
Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution). 63 A using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

1

-

6391

... More
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (Icu=lcs). 100 A 25kA using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

2

-

16530

... More
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A TPN using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

4

-

7108

... More
Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, progra mmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

1

-

8316

... More
Supplying, fixing and wiring 3 Phase Digital A mmeter / Voltmeter using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

1

-

1280

... More
Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

3

-

1515

... More
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

3

-

1392

... More
Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, kWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with co mmunication Port and Class 0.5s accuracy using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

1

-

8370

... More
Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6 mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4 x 30 x 6 mm Aluminium Strips using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

1.2

-

2656.8

... More
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mm using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

12

-

3300

... More
Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16SWG using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

120000

-

45600

... More
Supplying PVC/GI flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely. 25 mm using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

42

-

1302

... More
Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6 mm Copper strip using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

6

-

5748

... More
Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG Copper Wire using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

140

-

14700

... More
Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

6

-

24900

... More
Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975. 4 core 16 sq mm using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

140

-

25681.6

... More
Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975. 3.5 core 70 sq mm using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

240

-

101680.8

... More
Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe/ stoneware pipe /on wall / on pole as required. 6 to 16 sq mm using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

140

-

2261

... More
Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe/ stoneware pipe /on wall / on pole as required. 25 sq mm to 75 sq mm using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

240

-

5673.6

... More
Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc. complete.(As per Civil SR KSRB 1-2, P-7). In soil (hard) using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

320

-

24960

... More
Providing and laying in position 100 mm dia stone ware pipe in existing trench using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

10

-

2150

... More
Supplying and fixing LT cast Iron pot heads suitable for 1.1KV class UG cable filled with necessary bitumen/insulating compound complete with terminals, clamps, bolts, nuts and washers etc. 70 sq mm using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

4

-

1492

... More
Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only). 50 mm dia using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

2

-

384

... More
Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 70 sq mm Long Barrel using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

16

-

1520

... More
Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT > 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire > IK08. Power Factor >0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40 mm to 50 mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency>1301m/w, nominal CRI >75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 70 W using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

8

-

47640

... More
Supplying and Fixing of........ mm dia class A GI pipe bracket up to 2 Mtrs long bent at suitable angle and fixing to this bracket 1x40/2x40 watts fluorescent tube street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires. Using 25 mm dia G.I.Pipe using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

8

-

6696

... More
Supplying of Single Phase Open well Mono sub pump set 3 HP suitable for operation on 230 volts Single phase AC supply Make- Using group "A" materials. And as per the directions of engineer incharge of the work. ---- as per directions of engineer in charge of work.

1

-

19258

... More
Supplying and Delivery at Site 5 HP 12 Stage Three phase 6 inch/150mm Submersible Pump set of approved make ISI with Motor. Suitable for operation of three Phase 50 HZ 440 Volts A.C supply fitted with required accessories complete as per the approved rate Make - Make:Kirloskar/Calama/Lubi/Atlanta/Texmo/Suguna and as per the directions of Engineer in charge of the work. ---- as per directions of engineer in charge of work.

1

-

35950

... More
Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990. 3C x 2.5 sq mm using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

80

-

9040

... More
Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990. 3C x 4 sq mm using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

210

-

35070

... More
Providing and fixing to wall, ceiling and floor high density polyethylene pipes 6.00 kgf/sq.cm working pressure of outside diameter raising mains & exposed distribution pipes with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor,, including cost of all materials, labour charges, HOM and testing complete as per specifications. 50mm dia using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

180

-

59040

... More
Supplying push butTon operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 volts 1/3 phase motor upto 5 HP using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

2

-

2980

... More
Supplying and fixing single phase preventer using necessary wires over an existing panel board suitable for motor up to 20 HP capacities using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

1

-

805

... More
Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machineries like induction motor using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

2

-

864

... More
Fixing a shunt capacitor of ... KVAR capacity with necessary clamps, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor. 6 to 10 KVAR using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

2

-

412

... More
Supply and fixing polished wood board made of not less than 15 mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws. 12" x 12" x 2" using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

2

-

324

... More
Supplying, fixing and wiring 0 to 600Volts 96x96 mm AC Voltmeter on existing panel/wood board using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

1

-

407

... More
Supplying, fixing and wiring 0 to 30amps Direct Reading AC analog type A mmeter using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

1

-

418

... More
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

3

-

1392

... More
Supplying, installation and erection of Gate valve of 50 mm dia. using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

1

-

1688

... More
Supplying, installation and erection of Non Return valve of 50 mm dia. using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

1

-

1275

... More
Supplying, installation and erection of Borewell cap and clamp set. using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

1

-

1800

... More
Solar Water Heater system with heat exchanger Type 2 for Warm region, As per DGS & D rates. (Technical Specification enclosed)rated capacity in litres per day (LPD): 1000, Min. aparture area of collector (Sq mtrs): 18, Electrical heater back up (KW): 9, Capacity of make up tank (Ltrs): 10. Make DGS &D approved makesMake- group "A" materials. And as per the directions of engineer incharge of the work. ---- as per directions of engineer in charge of work.

3

-

497853

... More
Providing and fixing chlorinated poly vinyl chloride (CPVC ) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all C P V C plain and brass threaded fittings, including fixing the pipe with clamp at 1.00 mtrs spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete ( external work) a) for 40mm nominal OD Pipe using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

220

-

117480

... More
Providing and fixing chlorinated poly vinyl chloride (CPVC ) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all C P V C plain and brass threaded fittings, including fixing the pipe with clamp at 1.00 mtrs spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete ( external work) a) for 25mm diaMake- group "A" materials. And as per the directions of engineer incharge of the work. ---- as per directions of engineer in charge of work.

240

-

75840

... More
Providing and fixing chlorinated poly vinyl chloride (CPVC ) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all C P V C plain and brass threaded fittings, including fixing the pipe with clamp at 1.00 mtrs spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete ( external work) a) for 20mm nominal OD Pipe Make- group "A" materials. And as per the directions of engineer incharge of the work. ---- as per directions of engineer in charge of work.

180

-

43020

... More
Providing and fixing in position brass Gate Valve with C.I. wheel of app. Quality (Screw End) 40mm nominal bore including cost of all materials, labour and HOM of equipments with all leed complete as per specifications. a) for 40mm dia nominal using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

6

-

9000

... More
Providing and fixing in position brass Gate Valve with C.I. wheel of app. Quality (Screw End) 40mm nominal bore including cost of all materials, labour and HOM of equipments with all leed complete as per pecifications. a) for 25 mm dia nominal Make- group "A" materials. And as per the directions of engineer incharge of the work. ---- as per directions of engineer in charge of work.

3

-

3507

... More
Supplying & fixing M.S rectangular pole made of 2 equal angles 65 x 65 x 6 mm welded together & fixed in C.C (1:2:4) with 2 nos 16 mm dia MS . Hold fast rods each of length 25cms. Including cost of all materials cutting, bending scaffolding wherever neccessary, nicely finishing the welded joints with all lead lifts and as per the directions of the engineer-in-charge of the work and including providing 2 coats of approved quality paint over one coat of shop painting ( excluding cost of earthwork and concrete) including cost of materials, labour, HOM complete as per specifications using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

22

-

18876

... More
Providing Chain link fencing 50 mm size of 8 gauage properly streched between rectangular poles and fixed with sutable bolt & nuts, the free ends shall be welded to the pole & black pipe at top & bottom as required including cost of all materials, labour,lead and lifts and as per the directions of engineer-in-charge of the work including two coats of approved quality paint over one coat of shop paint, including cost of materials, labour, HOM complete as per specifications. using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

32

-

22880

... More
KSRB 4-1.6 : Providing & laying in position Plain cement concrete of Mix 1:2:4 with OPC@240 kgs, with 20mm and down size graded granite metal coarse aggregates @ 0.878 cum and fine aggregates @ 0,53 cum, machine mixed, concrete laid in layes not exeeding 15 cms. thick, well compacted, in foundation, plinth and cills, including cost of all materials, labour, HOM curing complete as per specifications using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

0.5

-

3011

... More
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mm using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

42

-

11550

... More
20mm Nominal size course aggregates using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

4.2

-

5670

... More
KSRB 7.9 : Providing and fixing MS grill work using MS falta or MS Square rods or combination of MS flats and square rods as per approved design drawing including cutting steel sections and welding the same to required pattern with a coat of red lead primer coat of materials, fixtures, labour and HOM complete as per specification using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

62

-

8122

... More
Supply, erection, testing and co mmissioning of 100KVA 5Star rated Aluminium/Copper wound Distribution Transformer 11 KV/433V with Off Load Tap Switch, Bocholt relay winding temperature indicator, oil temperature indicator, marshalling box with wiring, oil level indicator with+ 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved. 100 KVA -Aluminium Wound using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

1

-

212600

... More
LT Distribution Box for 100 kVA DTC with MCCB's (Sheet Metal) using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

1

-

22809

... More
LT Protection kit (Dwg No. BESCOM/GM/QS&S/10 Dtd 24.11.2018 using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

1

-

1915

... More
Double Pole TC Sets for erection of Transformers on RCC/PSCC 9 Mtrs Long Poles as per IS-1977, For 100/300kVA 4/5 Star Rated Transformers using 9 mtr RCC Pole 145Kg WL - GI using Group- A materials and as per the engineer incharge of the work. ---- as per directions of engineer in charge of work.

1

-

31844

... More
GOS as per IS-9921, IS-1977 11kV, 200 Amps Single Break GOS as per the BESCOM norms and Engineer Incharge of the Work. ---- as per directions of engineer in charge of work.

1

-

9125

... More
DOLO Cutouts as per IS-9385, Part-1 to 3, 11kV DOLO Cutouts Conventional to Erstwhile KEB Specification as per the BESCOM norms and Engineer Incharge of the Work. ---- as per directions of engineer in charge of work.

1

-

5672

... More
RCC Pole - 9 Mtr Long, 150 Kg WL Sq Section as per the BESCOM norms and Engineer Incharge of the Work. ---- as per directions of engineer in charge of work.

5

-

41130

... More
Cross Arms (MS & GI) as per IS-1977 11kV Horizontal X Arms - Galvanised Iron (GI) as per the BESCOM norms and Engineer Incharge of the Work. ---- as per directions of engineer in charge of work.

5

-

2525

... More
Cross Arms (MS & GI) as per IS-1977 11kV Special 3 Pin X Arm - MS as per the BESCOM norms and Engineer Incharge of the Work. ---- as per directions of engineer in charge of work.

1

-

921

... More
HT ST Support 50x6mm Flat - GI as per the BESCOM norms and Engineer Incharge of the Work. ---- as per directions of engineer in charge of work.

5

-

625

... More
11kV, 5KN Composite/Polymeric Pin Insulator (24mm dia FRP Rod) as per the BESCOM norms and Engineer Incharge of the Work. ---- as per directions of engineer in charge of work.

18

-

3978

... More
11kV, 45kN Polymeric Insulator as per the BESCOM norms and Engineer Incharge of the Work. ---- as per directions of engineer in charge of work.

6

-

1212

... More
Guy set complete with No.15 strain insulator & Cocreting matrials as per the BESCOM norms and Engineer Incharge of the Work. ---- as per directions of engineer in charge of work.

2

-

1504

... More
Labour charges for fixing of Guy set complete with No.15 strain insulator & Cocreting matrials as per the BESCOM norms and Engineer Incharge of the Work. ---- as per directions of engineer in charge of work.

2

-

708

... More
ACSR conductor as per IS-398 (Part - 2/1996), Rabbit ACSR (6/3.35 mm Al + 1/3.35 mm St), Std Wt : 214 kgs/km as per the BESCOM norms and Engineer Incharge of the Work. ---- as per directions of engineer in charge of work.

0.5

-

30757.5

... More
PG clamps for Rabbit to Rabbit conductor as per the BESCOM norms and Engineer Incharge of the Work. ---- as per directions of engineer in charge of work.

5

-

580

... More
Spiral Earth Electrode as per the BESCOM norms and Engineer Incharge of the Work. ---- as per directions of engineer in charge of work.

5

-

1240

... More
EG Stirrups (MS) with GI wire lacing as per the BESCOM norms and Engineer Incharge of the Work. ---- as per directions of engineer in charge of work.

5

-

1435

... More
Caution/Danger Board as per the BESCOM norms and Engineer Incharge of the Work. ---- as per directions of engineer in charge of work.

2

-

292

... More
Anti climbing device GI Barbed wire (12mtrs/Kg) as per the BESCOM norms and Engineer Incharge of the Work. ---- as per directions of engineer in charge of work.

12

-

1116

... More
Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 Amps three phase 4 wire whole current class-1 Accuracy Energy Meter. as per the BESCOM norms and Engineer Incharge of the Work. ---- as per directions of engineer in charge of work.

1

-

5125

... More
Supply and installation of 25 lts Water prifier as per the directions of the engineer incharge of the work ( approved make ) using group-A material and as per the engineer incharege of the work. ---- as per directions of engineer in charge of work.

12

-

300000

... More
Concealed Conduit System Supplying heavy gauge PVC conduit pipe19/20 mm dia 2 mm thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary .19/20mm dia 2mm thick ---- as per directions of engineer in charge of work.

80

-

4880

... More
Concealed Conduit System Supplying heavy gauge PVC conduit pipe 25 mm dia 2 mm thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 25 mm dia 2mm thick ---- as per directions of engineer in charge of work.

120

-

8400

... More
Concealed Conduit System Supplying heavy gauge PVC conduit pipe 32 mm dia 2.5 mm thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 32 mm dia 2.5 mm thick ---- as per directions of engineer in charge of work.

60

-

5580

... More
Supplying and Fixing Metal Fan Box with Round Hook. Make - Group "A" materials and as per the directions of Engineer in charge of the work. ---- as per directions of engineer in charge of work.

7

-

1141

... More
Supplying heavy gauge PVC Conduit Pipe 19/20 dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.19/20mm dia 2mm thick ---- as per directions of engineer in charge of work.

60

-

4500

... More
Supplying heavy gauge PVC Conduit Pipe 25 mm dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25 mm dia 2mm thick ---- as per directions of engineer in charge of work.

40

-

3200

... More
Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.. 1) 4way TP&N - Group "A" materials and as per the directions of Engineer in charge of the work ---- as per directions of engineer in charge of work.

1

-

3053

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. Make - Group "A" materials and as per the directions of Engineer in charge of the work.1-3Way ---- as per directions of engineer in charge of work.

8

-

984

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. Make - Group "A" materials and as per the directions of Engineer in charge of the work.6 Way ---- as per directions of engineer in charge of work.

4

-

848

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 8 Way ---- as per directions of engineer in charge of work.

8

-

2000

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 16-18 Way ---- as per directions of engineer in charge of work.

4

-

1416

... More
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5 sq mm (Phase & Neutral) & 1x1.0 sq mm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box ---- as per directions of engineer in charge of work.

14

-

3514

... More
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5 sq mm (Phase & Neutral) & 1x1.0 sq mm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box ---- as per directions of engineer in charge of work.

24

-

8664

... More
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5 sq mm (Phase & Neutral) & 1x1.0 sq mm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. long point above 6 mtr upto 10Mtr from tapping point to out let via switch box ---- as per directions of engineer in charge of work.

18

-

9756

... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sq mm Make - Group "A" materials and as per the directions of Engineer in charge of the work ---- as per directions of engineer in charge of work.

240

-

6240

... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sq mm Make - Group "A" materials and as per the directions of Engineer in charge of the work ---- as per directions of engineer in charge of work.

630

-

25200

... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sq mm Make - Group "A" materials and as per the directions of Engineer in charge of the work ---- as per directions of engineer in charge of work.

280

-

16520

... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sq mm Make - Group "A" materials and as per the directions of Engineer in charge of the work ---- as per directions of engineer in charge of work.

180

-

15660

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 1 to 3 Module ---- as per directions of engineer in charge of work.

8

-

1216

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 6 Module ---- as per directions of engineer in charge of work.

4

-

976

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 8 Module ---- as per directions of engineer in charge of work.

8

-

2416

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 16-18 Module ---- as per directions of engineer in charge of work.

4

-

1612

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 6Amps One Way Switch ---- as per directions of engineer in charge of work.

72

-

6336

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 6Amps Three Way socket ---- as per directions of engineer in charge of work.

20

-

3240

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Make - Group "A" materials and as per the directions of Engineer in charge of the work. Stepped Fan Regulator. ---- as per directions of engineer in charge of work.

7

-

2191

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 32Amps DP Switch ---- as per directions of engineer in charge of work.

4

-

1500

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 6/16Amps Universal Socket ---- as per directions of engineer in charge of work.

4

-

996

... More
Supplying and fixing of metal clad industrial plugs and sockets. 30 Amps ,3pole+earth 440V PLUG ---- as per directions of engineer in charge of work.

6

-

2202

... More
Supplying and fixing of metal clad industrial plugs and sockets. 30 Amps ,3pole+earth 440V SOCKET ---- as per directions of engineer in charge of work.

6

-

1782

... More
Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- as per directions of engineer in charge of work.

23

-

2714

... More
Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- as per directions of engineer in charge of work.

5

-

7710

... More
Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 C mm / Watt, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 �C by resistance method at 245 Volts, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, watt& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty. 48" Sweep 5 Star (1200 mm) ---- as per directions of engineer in charge of work.

7

-

20643

... More
Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI> 70%. efficacy > 100 lumen per watt, 120degree beam spread, life> 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF > 0.95, power loss should< 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2' / 1' x 4' 42-55 W ---- as per directions of engineer in charge of work.

13

-

79118

... More
Supplying & fixing of Surface mounting type retrofit type -LED tube ....... W comprising of LED linear source with CCT 6500 degree K, CRI> 70%. efficacy >80 lumen per watt, life> 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF > 0.95, power loss should < 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. Polycarbonate/OPAL Acrylic Casing 18W-20 W (T8) ---- as per directions of engineer in charge of work.

15

-

9330

... More
Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI> 70%. efficacy >80 lumen per watt, life> 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF > 0.95, power loss should < 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18W, 6500K ---- as per directions of engineer in charge of work.

16

-

6976

... More
Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall/ ceiling / Rafter / Girders ---- as per directions of engineer in charge of work.

28

-

3332

... More
Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ---- as per directions of engineer in charge of work.

7

-

1134

... More
Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 amps. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. ---- as per directions of engineer in charge of work.

5

-

2160

... More
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A DP ---- as per directions of engineer in charge of work.

6

-

6618

... More
Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V up to 300mA sensitivity on existing wood/panel board. 16-25 A 2 pole ---- as per directions of engineer in charge of work.

1

-

2536

... More
Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 63 A ---- as per directions of engineer in charge of work.

6

-

2232

... More
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 100 A 25kA ---- as per directions of engineer in charge of work.

1

-

8265

... More
Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A TPN ---- as per directions of engineer in charge of work.

2

-

3554

... More
Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. ---- as per directions of engineer in charge of work.

1

-

8316

... More
Supplying, fixing and wiring 3 Phase Digital A mmeter / Voltmeter ---- as per directions of engineer in charge of work.

1

-

1280

... More
Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound. ---- as per directions of engineer in charge of work.

3

-

1515

... More
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. ---- as per directions of engineer in charge of work.

3

-

1392

... More
Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6 mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4 x 30 x 6 mm Aluminium Strips ---- as per directions of engineer in charge of work.

0.75

-

1660.5

... More
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mm ---- as per directions of engineer in charge of work.

6

-

1650

... More
Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16SWG ---- as per directions of engineer in charge of work.

32000

-

12160

... More
Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6 mm Copper strip ---- as per directions of engineer in charge of work.

12

-

11496

... More
Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG Copper Wire. ---- as per directions of engineer in charge of work.

60

-

6300

... More
Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 6ft. Copper bonded rod with backfill compound ---- as per directions of engineer in charge of work.

6

-

31950

... More
1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 4 core 16 sq mm ---- as per directions of engineer in charge of work.

120

-

22012.8

... More
Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. LT Cable 2.5 sq mm to 25 sq mm ---- as per directions of engineer in charge of work.

120

-

1938

... More
UG Cable Work: Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed.In Ordinary Soil ---- as per directions of engineer in charge of work.

100

-

7800

... More
Brass Cable Gland. 45 mm dia ---- as per directions of engineer in charge of work.

2

-

384

... More
Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sq mm ---- as per directions of engineer in charge of work.

32

-

398.08

... More
Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT > 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire > IK08. Power Factor >0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40 mm to 50 mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency>1301m/w, nominal CRI >75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 70 W ---- as per directions of engineer in charge of work.

2

-

11910

... More
Supplying and Fixing of........ mm dia class A GI pipe bracket up to 2 Mtrs long bent at suitable angle and fixing to this bracket 1x40/2x40 watts fluorescent tube street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires. Using 25 mm dia G.I.Pipe ---- as per directions of engineer in charge of work.

2

-

1674

... More
Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. 2 HP, Size 50x40 Head 22M, Discharge 186 LPM. Make- Using group "A" materials. And as per the directions of engineer incharge of the work. ---- as per directions of engineer in charge of work.

1

-

17470

... More
Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:2010. 3C x 2.5 sq mm ---- as per directions of engineer in charge of work.

40

-

4520

... More
Supplying push butTon operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 volts 1/3 phase motor upto 5 HP. ---- as per directions of engineer in charge of work.

1

-

1490

... More
Supply and fixing polished wood board made of not less than 15 mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws. 12" x 12" x 2" ---- as per directions of engineer in charge of work.

1

-

162

... More
Supply and fixing polished wood board made of not less than 15 mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws. 20" x 20" x 2.5" ---- as per directions of engineer in charge of work.

1

-

315

... More
Supplying, fixing and wiring 0 to 600Volts 96x96 mm AC Voltmeter on existing panel/wood board. ---- as per directions of engineer in charge of work.

1

-

407

... More
Supplying, fixing and wiring 0 to 30amps Direct Reading AC analog type A mmeter ---- as per directions of engineer in charge of work.

1

-

418

... More
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. ---- as per directions of engineer in charge of work.

3

-

1392

... More
Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments. Size 50 mm ---- as per directions of engineer in charge of work.

1

-

1275

... More
Supplying and insstaling water purifire filter ---- as per directions of engineer in charge of work.

2

-

50000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.