Karnataka State Police Housing And Infrastructure Development Corporation Limited Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Karnataka State Police Housing And Infrastructure Development Corporation Limited - KSPHCL Tender

Civil And Construction
Building Construction
Opening Date9 Oct 2024
Closing Date8 Nov 2024
Tender Amount₹ 2,23,17,193.26 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2.1.2 15 Vol 1 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm and down size graded crushed coarse aggregates

140.07

6343

888559.2576

... More
2.2.3 15 Vol 1 - Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates For Column footing

139.02

7664

1065453.4506

... More
5.3 9 Vol 2 - Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)

41.53

6949

288616.888

... More
5.4 9 Vol 2 - Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)

31.25

7155

223615

... More
2.5.2 16 Vol 1 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. 2 M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates For Column. Ground Floor

23.04

13029

300189.7728

... More
2.5.2 16 Vol 1 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. 2 M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates For Column. First Floor

20.13

13105

263817.9423

... More
2.4.3 17 Vol 1 - Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates For Plinth beam.

29.54

10644

314437.9392

... More
1.9 7 Vol 1 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

233.05

297

69430.256

... More
1.8 7 Vol 1 - Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.

563.44

530

299119.0272

... More
6.8 14 Vol 2 - Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Ground Floor

84.84

8925

757220.7552

... More
6.8 14 Vol 2 - Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. First Floor

63.11

9014

568906.9883

... More
6.8 14 Vol 2 - Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Terrece Floor

23.95

9103

218035.7705

... More
6.15 14 Vol 2 - Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Ground Floor

24.64

1156

28507.4944

... More
6.15 14 Vol 2 - Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. First Floor

27.3

1168

31900.869

... More
2.1.4 15 Vol 1 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm and down size graded crushed coarse aggregates For coping & window cills. Ground Floor

11.24

7311

82177.7756

... More
2.1.4 15 Vol 1 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm and down size graded crushed coarse aggregates For coping & window cills. First Floor

1.88

7380

13875.9416

... More
2.1.4 15 Vol 1 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm and down size graded crushed coarse aggregates For coping & window cills. Terrece Floor

1.14

7450

8493.513

... More
2.5.2 16 Vol 1 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates For Staircase/Roofslab/Wall Shelves-Ground Floor

40.45

11496

465022.908

... More
2.5.2 16 Vol 1 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates For Staircase/Roofslab/Wall Shelves- First Floor

76.5

11572

885325.32

... More
2.5.2 16 Vol 1 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates For Lintels & Roofbeams-Ground Floor

21.95

12262

269165.387

... More
2.5.2 16 Vol 1 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates For Lintels & Roofbeams- First Floor

22.96

12339

283310.328

... More
2.5.2 16 Vol 1 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates For Plain Chejja-Ground Floor

0.75

11113

8334.7725

... More
2.5.2 16 Vol 1 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates For Plain Chejja-First Floor

0.7

11189

7832.769

... More
2.1.6 15 Vol 1 - KSRB 4-1.5 : Providing and laying in position plain cement concrete of mix M20 with OPC cement @ 300kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregtes @ 0.43cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, plinth and cills, including cost of all materials, labour, HOM of machinery, curing complete as per specifications.Specification No. KBS 4.1, 4.2 Sl.No-4.5/P-12. For Screed concrete with WPC over roof slab. Ground Floor

12.37

6992

86493.0192

... More
2.1.6 15 Vol 1 - KSRB 4-1.5 : Providing and laying in position plain cement concrete of mix M20 with OPC cement @ 300kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregtes @ 0.43cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, plinth and cills, including cost of all materials, labour, HOM of machinery, curing complete as per specifications.Specification No. KBS 4.1, 4.2 Sl.No-4.5/P-12. For Screed concrete with WPC over roof slab. First Floor

15.5

7062

109462.24

... More
2.11.a Vol 1 - Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) Ground Floor

25.76

100191

2580941.7984

... More
2.11.a Vol 1 - Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) First Floor

12.11

101193

1225456.4336

... More
8.19.1 44 Vol 2 4th Qtr. Issue rate - Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge.

66.8

285

19078.08

... More
8.9 42 Vol 2 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. For External walls Ground Floor

493.44

431

212771.328

... More
8.9 42 Vol 2 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. For External walls First Floor

311.87

435

135822.5037

... More
8.9 42 Vol 2 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. For External walls Terrece Floor

101.3

439

44553.766

... More
8.10 43 Vol 2 - Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. For Ceiling Ground Floor

415.68

236

98233.4976

... More
8.10 43 Vol 2 - Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. For Ceiling First Floor

229.71

238

54827.1828

... More
8.10 43 Vol 2 - Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. For Ceiling Terrece Floor

23.72

241

5717.706

... More
8.1.2 41 Vol 2 - Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. For Inside walls. Ground Floor

554.66

269

149713.8272

... More
8.1.2 41 Vol 2 - Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. For Inside walls. First Floor

369.6

272

100760.352

... More
8.1.2 41 Vol 2 - Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. For Inside walls. Terrece Floor

56.58

275

15577.6056

... More
8.51 50 Vol 2 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Ground Floor

1017.41

112

113949.92

... More
8.51 50 Vol 2 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. First Floor

686.14

112

76847.68

... More
8.51 50 Vol 2 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Terrece Floor

80.3

112

8993.6

... More
8.2.2 41 Vol 2 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ground Floor

52.71

312

16470.8208

... More
8.2.2 41 Vol 2 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. First Floor

61.74

315

19485.144

... More
8.16a 44 Vol 2 - Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20cms, c to c both horizontally and vertically fixed with chicken mesh for dropchajja.facia, backing to cup boards including cost of all materials,labour,providing and removing form work usage charges, curing, complete as per specifications. Ground Floor

16.92

1386

23460.5952

... More
8.16a 44 Vol 2 - Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20cms, c to c both horizontally and vertically fixed with chicken mesh for dropchajja.facia, backing to cup boards including cost of all materials,labour,providing and removing form work usage charges, curing, complete as per specifications. First Floor

43.22

1386

59927.1232

... More
9.24 63 Vol 2 - Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, Lakared, River Pink, Orissa Blue or equivalent. Ground Floor

174.72

3194

558097.6128

... More
9.24 63 Vol 2 - Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, Lakared, River Pink, Orissa Blue or equivalent. First Floor

47.39

3226

152888.6702

... More
9.34 64 Vol 2 - Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. Ground Floor

25.21

1730

43623.384

... More
9.34 64 Vol 2 - Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. First Floor

20.71

1747

36194.867

... More
9.17.2 61 Vol 2 - Providing and laying Polished Glazed Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm Ground Floor

102.57

1316

134982.12

... More
9.17.2 61 Vol 2 - Providing and laying Polished Glazed Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm First Floor

109.31

1329

145290.4796

... More
9.11 60 Vol 2 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. Ground Floor

27.63

995

27510.6384

... More
9.11 60 Vol 2 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. First Floor

22.21

1005

22335.2644

... More
9.39 65 Vol 2 - Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. Ground Floor

52.71

1622

85542.0048

... More
9.39 65 Vol 2 - Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. First Floor

61.74

1639

101198.6514

... More
1.23 11 Vol 1 - Providing and Filling in foundation with granite/trap broken metal 100mm and downsize & with approved sand including hand packing. ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications.

54.71

3003

164340.0864

... More
9.2 59 Vol 2 - Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge.

70.33

896

63015.68

... More
12.93.2 111 Vol-2 - Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Ground Floor

39.7

855

33970.496

... More
12.93.2 111 Vol-2 - Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) First Floor

33.55

855

28708.064

... More
12.51 104 Vol 2 - Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. Ground Floor

7

1137

7965.44

... More
12.51 104 Vol 2 - Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. First Floor

6

1137

6827.52

... More
12.57.4 105 Vol 2 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemical treated hard wood battens and internal frame with minimum 45 mm wide wooden frame al round door shutters covered with cross bonded wooden sheets ( core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 ( part-I) 1991. from manufacturer complete as per specification. 35 mm thickness Ground floor

4.92

4525

22267.5264

... More
12.57.4 105 Vol 2 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemical treated hard wood battens and internal frame with minimum 45 mm wide wooden frame al round door shutters covered with cross bonded wooden sheets ( core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 ( part-I) 1991. from manufacturer complete as per specification. 35 mm thickness First floor

6.56

4571

29986.9408

... More
12.57.1 105 Vol 2 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemical treated hard wood battens and internal frame with minimum 45 mm wide wooden frame al round door shutters covered with cross bonded wooden sheets ( core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 ( part-I) 1991. from manufacturer complete as per specification 30 mm thickness Ground Floor

9.02

3903

35206.864

... More
12.57.1 105 Vol 2 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemical treated hard wood battens and internal frame with minimum 45 mm wide wooden frame al round door shutters covered with cross bonded wooden sheets ( core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 ( part-I) 1991. from manufacturer complete as per specification 30 mm thickness First Floor

4.41

3942

17385.2343

... More
12.96 112 Vol 2 - Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame Ground Floor

20.4

720

14691.264

... More
12.96 112 Vol 2 - Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame First Floor

20.4

720

14691.264

... More
12.97.1 112 Vol 2 - Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames 30 mm thickness. Ground Floor

6.97

3588

25011.7056

... More
12.97.1 112 Vol 2 - Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames 30 mm thickness. First Floor

6.97

3588

25011.7056

... More
12.87 111 Vol 2 - Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8-2.0mm. Maximum possible size 1519mm x 1519mm (The cost is inclusive of all fixtures and separate charges for minor T P's shall not be made) Ground Floor

19.85

7337

145641.832

... More
12.87 111 Vol 2 - Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8-2.0mm. Maximum possible size 1519mm x 1519mm (The cost is inclusive of all fixtures and separate charges for minor T P's shall not be made) First Floor

19.25

7337

141239.56

... More
11.34B 86 Vol 2 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. Ground Floor

1155.05

204

236739.048

... More
11.34B 86 Vol 2 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. First Floor

404.145

204

82833.5592

... More
11.28 85 Vol 2 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge,(for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.

969.255

632

613344.564

... More
18.7 184 Vol 2 - Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.

44.8125

8906

399110.88

... More
7.17.2 39 18 19 DWD SR - KSRB 7.17 : Providing, fabricating, assembling and fixing in position aluminium doors using following aluminium mat finish or glossy finish, outer frame plain section 101.6x44.45mm thickness 3.18mm, section weight 2.404 kg/m, door shutters vertical section 44.62x44.45mm thickness 3.18mm, section weight 1.505kg/m, top section 47.62x44.45mm thickness 3.00mm, section weight 1.426kg/m bottom section 114.3x44.45 thickness 3.18mm, section weight 2.646kg/m, door central section 49.91x44.45mm thickness 3.00mm, section weight 1.495 kg/m glazing clips 19x17.3x11mm thickness 0.9mm section weight 0.124kg/m; aluminium sections cut to length joint metredcorners grinded, the shutters pivoted opening arrangement with heavy duty aluminium alloy automatic door closures floor mounted, providing and fixing standard approved accessories, such as aluminium handle for full width or length, tower bolts, lock, pivots: P.V.C. or rubber gasket with 5.5m. thick plain glass for top and bottom panel; aluminium sections treated for removal of any rust and prevention of further rust formation, and coated with greasy materials for non-adherance of mortars or any other sticky materials; the assembled frame fitted with the corner angles, strips and fitted with screws, rawl plugs or teakwood gutties to R.C.C. columns or masonry on sides. beams and flooring in bottom. including cutting, chistling and making good with cement mortar to match the surface; all the frames throughly cleaned free from rust, scale, or dirt including cost of materials, fixtures, labour and HOM of machinery complete as per specifications.using aluminium section powdered coated to a minimum of 60-70 microns with exterior durable pure polyester grade powder of approved quality.

3.75

6966

26124

... More
8.30 46 Vol 2 - Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Ground Floor

527.28

194

102756.3264

... More
8.30 46 Vol 2 - Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. First Floor

398.31

196

78399.3573

... More
8.30 46 Vol 2 - Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Terrece Floor

101.3

198

20136.414

... More
8.54.2 & 8.55.2 50 & 51 Vol 2 - Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. For Ceiling & Inside walls Ground Floor

1007.51

182

183931.0256

... More
8.54.2 & 8.55.2 50 & 51 Vol 2 - Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. For Ceiling & Inside walls First Floor

638.39

182

116544.4784

... More
8.54.2 & 8.55.2 50 & 51 Vol 2 - Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. For Ceiling & Inside walls Terrece Floor

80.2953

182

14658.709968

... More
8.41 48 Vol 2 - Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Ground Floor

42.777

187

8001.01008

... More
8.41 48 Vol 2 - Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. First Floor

39.09

188

7384.4919

... More
8.3.1 41 Vol 2 - Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. For Flagging

106.19

396

42102.2112

... More
8.79 54 Vol 2 - Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove Ground Floor

1038.94

58

60507.8656

... More
8.84 55 Vol 2 - Providing wall black boards in CM 1:3 with two coats of black paint including finishing etc., complete. P.No 255. I.No 37.30.

10.75

532

5719

... More
8.3 63 Vol 3 - Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade

10000

1

17900

... More
8.40 48 Vol 2 - Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.

10.6

128

1365.28

... More
15.2 149 Vol 2 - Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.

610.65

825

504054.936

... More
4.1 5 Vol 2 - Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.

482.37

132

63750.0192

... More
10.2 69 Vol 2 - Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. Ground Floor

105.36

367

38705.0496

... More
NSR - Providing and fixing of Signage boards etc. complete with all lead, lifts, loading, unloading, scaffolding arrangement, cost and conveyance of all materials, labour, equipment, transportation charges, testing and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and as per the directions of the Engineer in-charge of the work.

1

106400

106400

... More
12.68.1 106 Vol 2 - Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. 125x65x2.12mm First Floor

48

61

2956.8

... More
12.68.2 106 Vol 2 - Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. 100x58x1.9mm Ground Floor

42

48

2022.72

... More
12.72 107 Vol 2 - Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete Ground Floor

60

91

5510.4

... More
12.73.1 107 Vol 2 - Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete :125mm Ground Floor

60

49

2956.8

... More
12.58 105 Vol 2 - Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. Ground Floor

21

134

2822.4

... More
22.15.3 218 Vol 2 - Providing and fixing Aldrops for door shutters with necessary screws, etc. complete. Ground Floor

30

336

10080

... More
589 A 30 Vol 2 21 22 SR - Providing and fixing teak wood beading for door shutters Ground Floor

78

67

5241.6

... More
9.20.2 62 Vol 2 - Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Ground Floor

96.22

234

22523.1776

... More
9.20.2 62 Vol 2 - Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. First Floor

101.8

236

24067.556

... More
10.15.1 71 Vol 2 - Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns /beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheetmaking a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reversesides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts completewith spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete.For Straight Portion

52.56

4467

234821.2608

... More
10.10.1 70 Vol 2 - Providing and fixing in wall lining flat pressed three layer (medium den sity) particle board or graded wood Pre-laminated one side decorative lamination and other side balancing lamination Grade I, Type II, IS : 12823 marked, including priming coat on unexposed arrangement and screws etc. complete 12 mm thick

37.44

1242

46503.4752

... More
NSR 1 - Furnitures: -Supply of Manager table with a size of 1800(L) x 750(h) with 25mm thick Table top with 25mm thick leg with 18mm thick Medestry panel with side storage unit with a size of 900(L) x 450x750) with draw at top and shetter at bottom whole unit mounted on levellers PI Room

1

29800

29800

... More
NSR 2 - Supply of High back chair with headrest cussion at seat and perfo at back with chrombase with gaslift mounted on casters with synchro mechanisum with adjustable handies

1

9800

9800

... More
NSR 3 - Supply of visitor chair cussion at seating and backrest area with Ms framing

9

4800

43200

... More
NSR 4 - Supply of computer table with size of 1200(L)x600(d)x750(h) with 25mm thick with table top and 18mm thick below table top leg and apron with powder coated metal keyboard tray with CPL Trolly and pedastal unit with a size of 640(h)x400(W)x450(d) wooden draw

3

8500

25500

... More
NSR 5 - Supply of medium back Computer Chair with cusion at seat and perfro at black with powder coated metal base mounted on bushes with adjustable handles

2

6500

13000

... More
NSR 6 - Supply of Tandem chair of 3 seater with powder coated metal structure mounted on levellers.

3

9800

29400

... More
1.6.1 6 Vol 1 - Water Supply- Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing oFirst Floor or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.

32

542

17346.56

... More
1.10 7 Vol 1 - Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications

31.05

179

5564.16

... More
13.32.3 119 Vol 2 - Providing and fixing Chlorinated Polyvinyl Chloride(CPVC)pipes, having thermal stability for hot & cold watersupply,including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25mm (Internal)

50

534

26712

... More
13.33.4 119 Vol 2 - Providing and fixing Chlorinated Polyvinyl Chloride(CPVC)pipes, having thermal stability for hot & cold watersupply,including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32mm (External)

90

416

37497.6

... More
13.1 M1501 140 Vol 5 - Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges,handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.(PVC pipe of 6Kgs/Sqm )-75mm dia

200

215

43008

... More
13.2 M150J 140 Vol 5 - Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges,handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.(PVC pipe of 6Kgs/Sqm )-90mm dia

90

288

26006.4

... More
13.3 140 M150K Vol 5 - Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges,handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.(PVC pipe of 6Kgs/Sqm )-110mm dia

150

400

60144

... More
13.5 M150M Vol 5 - Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges,handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.(PVC pipe of 6Kgs/Sqm )-160mm dia

140

723

101292.8

... More
NSR7 - Providing and fixing in position Pillar cock of Jaquar/Hindware/Parry ware of approved quality 20mm nominal bore including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for succesSecond Floorul completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work.

6

1250

7500

... More
NSR8 - Providing and fixing in position Short body cock/tap of Jaquar/Hindware/Parry ware of approved quality 20mm nominal bore including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for succesSecond Floorul completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work.

6

1250

7500

... More
NSR9 - Providing and fixing in position Long body cock/tap of Jaquar/Hindware/Parry ware of approved quality 20mm nominal bore including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for succesSecond Floorul completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work.

4

1350

5400

... More
NSR10 - Providing and fixing in position Angle stop cock of Jaquar/Hindware/Parry ware of approved quality 20mm nominal bore including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for succesSecond Floorul completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work.

6

1250

7500

... More
NSR11 - Providing and fixing in position Two way bib cock of Jaquar/Hindware/Parry ware of approved quality 20mm nominal bore including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for succesSecond Floorul completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work.

2

1350

2700

... More
NSR12 - Providing and fixing in position Health faucet complete set of Jaquar/Hindware/Parry ware of approved quality 20mm nominal bore including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for succesSecond Floorul completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work.

2

1350

2700

... More
13.46 119 Vol 2 - Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors: 100mminletand75mmoutlet ,Hubless centrifugally cast(spun) iron epoxy coated inside and outside as per IS:15905

8

532

4256

... More
13.34 119 Vol 2 - Providing and placing on terrace (at all floor levels ) polyethylene water storagetank, IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittinigs and the base support for tank.

1000

10

10080

... More
11.50.2 75 SR2018 19 - KSRB 12-8.1 : Constructing brick masonry inspection chamber for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C I cover withframe (light duty) internal dimensions, total weight of cover with frame to be not less than 38 kg ( weight of cover 23kg and weight of frame 15 kg) R. C. C. top slab with cement concrete M 15 with 20mm and downsize granite metal, foundation concrete M 5 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications.Specification No. KBS 600x600mm and 450mm depth (clear inside dimension) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1 5, C I cover withframe (light duty) 600x600mm

5

6108

30542.4

... More
11.50.3 75 SR2018 19 - KSRB 12-8.1 : Constructing brick masonry inspection chamber for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C I cover withframe (light duty) internal dimensions, total weight of cover with frame to be not less than 38 kg ( weight of cover 23kg and weight of frame 15 kg) R. C. C. top slab with cement concrete M 15 with 20mm and downsize granite metal, foundation concrete M 5 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications.Specification No. KBS 450x450mm and 450mm depth (clear inside dimension) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1 5, C I cover withframe (light duty) 450x450mm

8

4744

37954.56

... More
13.4.1 115 Vol 2 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :25mm dia

1

614

614.88

... More
13.4.2 115 Vol 2 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :32mm dia

1

669

669.76

... More
13.4.4 115 Vol 2 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :50mm dia

2

957

1915.2

... More
14.3.1 123 Vol 2 - Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid

2

6694

13388.48

... More
14.1.1 123 Vol 2 - Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests

4

5470

21880.32

... More
14.7.2 124 Vol 2 - Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15mm C.P. brass pillar tap

6

2868

17211.72

... More
37.35 269 SR 2018 19 - Wall bores in Brick masonry upto 45 em thick. including cost of materials, labour, HOM complete as per specifications.

25

141

3528

... More
37.36.1 269 SR 2018 19 - Wall bores in size stone masonry. including cost of materials, labour, HOM complete as per specifications. upto 45 em thick.

10

339

3393.6

... More
A 21 302 Vol 2 - Providing & fixing Indian marble partitions at urnals as per specification directions Engineer in charge of work.

7.5

2072

15540

... More
14.32.2 128 Vol 2 - Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm

6

1140

6840.96

... More
14.40.2 130 Vol 2 - Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and eFirst Floorective height of 88 mm, weighing not less than 190 g.

6

535

3212.16

... More
NSR13 - Providing 10cms dia PVC cowl with cap of approved 1 st quality and make conforming to ISI specifications and fixing in position as directed (Rate includes cost of materials fixtures including conveyance charges to the work spot)

2

256

512.96

... More
12.111, 90 DWD SR 2018 19 - Providing and fixing 7.5 cms to 15.00 cms dia NP grating 100 mm dia..

8

168

1344

... More
2.6 N010F142 Vol 5 - Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For Medium Duty GI pipe of 50mm dia

35

654

22892.8

... More
14.23 127 Vol 2 - Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively.

4

1292

5169.92

... More
17.14 153 Vol 2 - Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaFirst Floorolding, usage of machinery, curing, lead and lift charges etc, Complete.

10

1310

13104

... More
2.2.2.1 15 Vol 1 - Sump Tank: Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates For bottom slab & side RCC Walls

32.7

7805

255254.565

... More
2.2.1.1 15 Vol 1 - Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates For Roofslab

5.62

10886

61181.568

... More
8.6.2 42 Vol 2 - Providing 20 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonry including rounding oFirst Floor corners wherever required smooth rendering, providing and removing scaFirst Floorolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.

133.4

480

64096.032

... More
H140A , 111 Vol 5 - Providing and fixing MS inspection door of size 60 cms x 60 cms, including MS frame made of 50x50x6mm angle, shutters made of 3mm thick MS sheets, with hinges, locking arrangements at top etc. including painting with anticorrosive approved paint etc. complete including all lead and lifts etc.

1

2396

2396.8

... More
H110B, 111 Vol 5 - Providing and fixing MS ladder between landings, 45 cms wide using angle iron of specified sizes, 20mm MS bars at 25 cms. centre to centre, with necessary supports of same angle iron etc. as directed, including hand railing on both sides with 25mm dia. GI pipes with angle iron props at 2 mtrs. intervals and 0.5M heigh, including fixing in ground with CC 1:2:4 and two coats of anticorrosive bituminous paint etc. with all lead and lifts etc. complete with: MS angle of 65 x 65 x 10mm

4.5

5377

24197.04

... More
2.2.2.2 , 15 Vol 1 - Septic Tank: Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates For bottom slab & side RCC Walls

9.77

7805

76264.1315

... More
2.2.2.1 15 Vol 1 - Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates For Roofslab

2.24

10886

24385.536

... More
8.6.2 , 42 Vol 2 - Providing 20 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonry including rounding oFirst Floor corners wherever required smooth rendering, providing and removing scaFirst Floorolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.

67.78

480

32566.9344

... More
5.1 , 25 DWD SR 2018 19 - Soak Pit: KSRB 5-1.1 : Providing and constructing granite I trap I basalt rubble stone masonry in foundation with mud mortar (uncoursed), bond stones at 2m. apart in each course including cost of materials, labour, curing complete as per specifications. KBS 5.1.12

4.68

2640

12359.6928

... More
6.4, 17 Vol 2 - Providing and Filling in foundation with granite/trap broken metal 100mm and downsize & with approved sand including hand packing. ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications.

4.58

3003

13757.5872

... More
17.14, 153 Vol 2 - Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaFirst Floorolding, usage of machinery, curing, lead and lift charges etc, Complete.

5.15

1310

6748.56

... More
1.11 , 7 Vol 1 - Supplying and filling in plinth with sand under floors, foundation of Bridges including watering, ramming, consolidating and dressing complete.

3.12

2438

7607.3088

... More
1.10, 7 Vol 1 - Rain Water Harwesting: Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications

52.26

179

9364.992

... More
13.3 , 140 M150K Vol 5 - Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges,handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.(PVC pipe of 6Kgs/Sqm )

111

400

44506.56

... More
11.50.3 , 76 DWD SR 2018 19 - KSRB 12-8.1 : Constructing brick masonry inspection chamber for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C I cover withframe (light duty) internal dimensions, total weight of cover with frame to be not less than 38 kg ( weight of cover 23kg and weight of frame 15 kg) R. C. C. top slab with cement concrete M 15 with 20mm and downsize granite metal, foundation concrete M 5 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications.Specification No. KBS 450x450mm and 450mm depth (clear inside dimension) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1 5, C I cover withframe (light duty) 450x450mm

6

4744

28465.92

... More
5.1 , 25 DWD SR 2018 19 - KSRB 5-1.1 : Providing and constructing granite I trap I basalt rubble stone masonry in foundation with mud mortar (uncoursed), bond stones at 2m. apart in each course including cost of materials, labour, curing complete as per specifications. KBS 5.1.12

7.25

2460

17841.96

... More
6.4 , 17 Vol 2 - Providing and Filling in foundation with granite/trap broken metal 100mm and downsize & with approved sand including hand packing. ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications.

6.97

3003

20936.7648

... More
17.14 , 153 Vol 2 - Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaFirst Floorolding, usage of machinery, curing, lead and lift charges etc, Complete.

6

1310

7862.4

... More
2.2.1.1. , 15 Vol 1 - Compound wall: Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates For Column footing

4.14

7805

32316.633

... More
8.37 , 48 Vol 2 - Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :New work (two coats) including a coat of approved steel primer but excluding a coat of mordant solution including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.

21.6

146

3169.152

... More
2.2.1.1 , 65 Vol 1 - Road: Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.For RCC head walls to the CD work.

26.71

7805

208496.9245

... More
8.6.2 , 42 Vol 2 - Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding oFirst Floor corners wherever required smooth rendering, providing and removing scaFirst Floorolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. For Concrete surface

58.8

480

28252.224

... More
3.11 , 16 Vol 3 - Preparation and surface treatment of formation by removing mud and slurry, watering to the extent needed to maintain the desired moisture content, trimming to the required line, grade, profile and rolling with 8-10 t smooth wheeled roller, complete as per clause 310.

110

4

492.8

... More
3.6 17 Vol 3 - Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads,transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2

33

552

18221.28

... More
4.27 , 24 Vol 3 - Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.

13.5

2866

38692.08

... More
4.1 V , 19 Vol 3 - Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 For Grading -V Material

13.5

2785

37603.44

... More
20.29 , 138 Vol 3 - Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, , primer, sealant , curing of concrete slabs for 14days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work.

18

7586

136563.84

... More
22.8.1 , 176 DWD SR 2018 19 - Providing groove cutting for width of 5mm to 1Omm and depth 80mm-100mm including cost of cutting machine, generator & HOM, including cost of blade, coolant etc., including cleaning of groove & providing sand and hot bitumen fillars, and filler metal etc. , including cost of conveyance of all materials, labour, lead and lift charges and all other incidental charges as per drawing and as per specifications.-for concrete pavement

81

151

12247.2

... More
9.32 , 64 Vol 2 - Providing and laying heavy duty cobble stones 75mm thick interlock pavers, using cement and course sand for manufacture of blocks of approved size, shape and colour with a minimum compressive strength of 281 kg per m2 over 50mm thick sand bed average thickness and compacting with plate vibrator having 3 tons compaction force thereby forcing part of sand underneath to come up in between joints, final compaction of paver surface joints into its final level, including cost of materials, labour and Usage charges of machinery complete as per specifications.

210

1282

269304

... More
12.4 140 Vol 5 - Geophysical investigation of site for sinking Bore well for supplying drinking water to the habitaion either through hand pump scheme mini water supply scheme or piped water supply scheme by vertical elctrical sounding by adopting vannur are schlumbergers method . including re connissance survey of geological formation. Geohidroligical investigation of existing ground water in the vicinity its quality. Quantity and acceptablity of the user. Indicating the location of site . Recommended depth of casing pipe required to seal the top un consolidated formation including extra depth of 1mt in consolidated formation for proper ceating of casing pipes. Depth of drilling corvering full depth of aquifer proposed to be tapped. probable yield and other information required for safe drinking and harnessing including transportation of instrument and accessories to work site. engaging techinical personnel and lobour required etc complete. with all lead, lifts, loading, unloading and HOM charges of all other incidental charges required for succesSecond Floorul completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. As per directions of engineer in charge of work.

1

5552

5552.4

... More
12.2.1 139 Vol 5 - Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG and above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc. for: Up to 0.00 to 50.00 mtrs

50

324

16222.5

... More
12.2.2 139 Vol 5 - Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG and above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc. for: Up to 50.00 to 100.00 mtrs

50

406

20317.5

... More
12.2.3 139 Vol 5 - Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG and above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc. for: Up to 100.00 to 150.00 mtrs

50

432

21630

... More
12.32 143 Vol 5 - Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty.

20

2029

40593

... More
I.No O170A 154 Vol 5 - Providing and fixing MS casing collars as per IS 1239 part-II 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm minimum. The dimensions of caps and colars shall be strictly as per IS 1239 Part-II 1982 with all amendments

6

157

945

... More
I.No O180A 155 Vol 5 - Providing and laying at site of work MS casing caps as per IS 1239 partII 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm minimum. The dimensions of caps and colars shall be strictly as per IS 1239 Part-II 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge

1

172

172.2

... More
1 1.2.1 Vol 6 - Eletcrical: Concealed Conduit System Supplying heavy gauge PVC conduit pipe mm dia. mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19-20 mm dia 2 mm thick

680

66

44880

... More
1 1.2.2 Vol 6 - Concealed Conduit System Supplying heavy gauge PVC conduit pipe ...... mm dia. mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thick

520

78

40560

... More
3 1.12 Vol 6 - Supplying And Fixing M.S. Rafter Clamp Set made out of M.S. Flat and 14 mm M.S. rod.

9

160

1440

... More
3 1.13 Vol 6 - Supplying And Fixing Metal Fan Box with Round Hook.

10

117

1170

... More
1 1.3.1 Vol 6 - Supplying heavy gauge PVC Conduit Pipe .... dia mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20 mm dia 2 mm thick

250

68

17000

... More
1 1.3.2 Vol 6 - Supplying heavy gauge PVC Conduit Pipe dia mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25 mm dia 2 mm thick

360

79

28440

... More
17 5.19.9 Vol 6 - Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.-II - Double Door 12 Way SP and N

3

2329

6987

... More
7 3.4.1 Vol 6 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2 Way

28

138

3864

... More
7 3.4.3 Vol 6 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. Make - Group "A" materials and as per the directions of Engineer in charge of the work.4-5 Way

8

177

1416

... More
7 3.4.4 Vol 6 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6 Way

18

220

3960

... More
7 3.4.5 Vol 6 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way

10

261

2610

... More
7 3.4.6 Vol 6 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12 Way

6

319

1914

... More
7 3.4.7 Vol 6 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 16 Way

2

363

726

... More
4 2.2.1 Vol 6 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm Phase and Neutral and 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire confirming to IS-694: and latest amendments without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box

26

269

6994

... More
4 2.2.2 Vol 6 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm Phase and Neutral and 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire confirming to IS-694: and latest amendments without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box

48

379

18192

... More
4 2.2.3 Vol 6 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm Phase and Neutral and 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire confirming to IS-694: and latest amendments without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box

36

555

19980

... More
4 2.3.2 Vol 6 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010 1.5 mm2

1300

26

33800

... More
4 2.3.3 Vol 6 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 mm2

2550

42

107100

... More
4 2.3.4 Vol 6 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 4 mm2

840

63

52920

... More
4 2.3.5 Vol 6 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 6 mm2

300

92

27600

... More
7 3.5.1 Vol 6 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module

28

137

3836

... More
7 3.5.3 Vol 6 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.4 Module

8

175

1400

... More
7 3.5.4 Vol 6 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module

18

234

4212

... More
7 3.5.5 Vol 6 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module

10

284

2840

... More
7 3.5.6 Vol 6 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module

6

344

2064

... More
7 3.5.7 Vol 6 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 16 Module

2

397

794

... More
8 3.6.1 Vol 6 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch

140

102

14280

... More
8 3.6.2 Vol 6 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Two Way Switch

8

166

1328

... More
8 3.6.3 Vol 6 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Three Way socket

44

171

7524

... More
8 3.6.4 Vol 6 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module

12

357

4284

... More
8 3.6.9 Vol 6 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32A DP Switch

4

326

1304

... More
8 3.6.10 Vol 6 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal Socket

4

236

944

... More
8 3.13.4 Vol 6 - Supplying and fixing of metal clad industrial plugs and sockets. 32 Amps ,3pole+earth 440V PLUG

3

609

1829.58

... More
9 3.13.8 Vol 6 - Supplying and fixing of metal clad industrial plugs and sockets. 32 Amps ,3pole+earth 440V SOCKET

3

827

2483.46

... More
51 12.46 Vol 6 - Supplying and Fixing of 70-150 W lamp holder 2 Pin

56

63

3528

... More
29 6.1 Vol 6 - Supplying exhaust fan of 1440 RPM of 300 mm 12" size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.

6

1492

8952

... More
29 6.3.1 Vol 6 - Supplying capacitor type ceiling fan complete with down rod blades,shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep 1200 mm Regular model

19

2984

56696

... More
29 6.5.1 Vol 6 - Supplying wall mounting fan suitable to operate at single- phase 230v AC. supply. 300 mm Sweep

2

2492

4984

... More
43 11.5.2 Vol 6 - Supply of round/square recess/surface mounted rolling type LED Down light with W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector and has swivelling unit of aluminium die cast eye ball and LED Lamp position retained by circular wire spring,with Life of 25000 burning hours and 70% lumen maintenance with CRI 80. Power Input: 220-240V at 50/60Hz and Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical conditionLED square or round down light 10-12W

4

885

3540

... More
44 11.6.3 Vol 6 - Supplying of recess mounting non integral type LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70 percentage. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 and LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp Wage., short circuit and open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition-LED modular down light 2'x2' 36 W

8

4553

36424

... More
42 11.3.2 Vol 6 - Supplying of .....feet -PVC Batten with integrated LED tube 20/22 W with high quality diffuser with Life of 25000 burning hours and 70% lumen maintenance with CRI 80. Power Input: 220- 240V@ 50/60Hz and Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.-LED light fitting 1 x 4' - 20/22 W

36

690

24840

... More
46 11.11.7 Vol 6 - Supplying and fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 and LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit and open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.18W, 6500K

20

426

8520

... More
55 13.7.1 Vol 6 - Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps.On wall/ ceiling / Rafter / Girders

44

122

5368

... More
56 13.10 Vol 6 - Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.

19

171

3249

... More
56 13.12 Vol 6 - Extra length of GI pipe of class B 19 mm dia for down rod.

8

197

1576

... More
56 13.14 Vol 6 - Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.

6

492

2952

... More
47 12.2.1 Vol 6 - Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell

2

246

492

... More
16 5.18.4 Vol 6 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898-6-32 A DP

14

739

10346

... More
17 5.20.1 Vol 6 - Supplying, fixing and wiring Residual current circuit breaker RCCB 240/450V upto 300mA sensitivity on existing wood/ panel board.16A-25A 2 pole

3

4277

12831

... More
37 9.3.3 Vol 6 - Supplying, erecting, testing and commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete

1

68383

68383

... More
38 9.5.9 Vol 6 - Supplying, installation, testing and commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 150 AH capacity

10

15895

158950

... More
8 3.6.11 Vol 6 - Networking: Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone Socket

3

156

468

... More
8 3.06.12 Vol 6 - Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. RJ45/I.O Outlet Cat-6

18

337

6066

... More
35 8.1 Vol 6 - Supplying and drawing UTP-CAT 6E LAN cable.

820

38

31160

... More
35 8.2.2 Vol 6 - Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable.-2Pair

180

21

3780

... More
35 8.3 Vol 6 - Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6.

80

44

3520

... More
35 8.4.4 Vol 6 - Supplying and Fixing of switch mounting rack with power manager and Cable manager.-12U with 450mm depth

1

8835

8835

... More
35 8.9.11 Vol 6 - Supplying fixing of Network Switches-16 port 10/100/1000 Switch

1

6440

6440

... More
35 8.10.1 Vol 6 - Supplying and fixing of I/O socket with back box-Single I/O

18

490

8820

... More
36 8.11.3 Vol 6 - Supplying and Fixing of ... Mtrs Cat 6 Patch Cable. 3mtr

18

331

5958

... More
36 8.12.2 Vol 6 - Supplying and Fixing of Patch panel for LAN cabling. 24 Port 101100 patch panel

1

4100

4100

... More
36 8.13.1 Vol 6 - Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination.-10 Pair

1

345

345

... More
13 5.7.3 Vol 6 - Paneling work: Supplying and fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 63 A

6

401

2406

... More
14 5.12.1 Vol 6 - Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. SMEnclosure Sheet Metal Execution 63 A

1

6881

6881

... More
16 5.15.9 Vol 6 - Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . Icu=100% lcs. In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open. Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.100 A 25 kA

1

8487

8487

... More
16 5.18.7 Vol 6 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898-6-32 A TPN

3

1717

5151

... More
17 5.21 Vol 6 - Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.

1

9255

9255

... More
18 5.29 Vol 6 - Supplying, fixing and wiring 3 Phase Digital A mmeter / Voltmeter

1

1425

1425

... More
18 5.34 Vol 6 - Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound.

3

562

1686

... More
18 5.38 Vol 6 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.

3

515

1545

... More
19 5.40.1 Vol 6 - Supplying A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete-100 A 4 x 30 x 6 mm Aluminium Strips

0.75

2465

1848.75

... More
19 5.41.1 Vol 6 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint-40 x 40 x 6 mm

8

305

2440

... More
19 5.42.2 Vol 6 - Fabricating supplying and mounting MS box made out SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete-16 SWG

64000

-

27520

... More
2 1.9.2 Vol 6 - Supplying PVC flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 25 mm

18

22

396

... More
54 12.58.7 Vol 6 - UG Cable: GI/Copper strips for grounding connections, using necessary fixing materials as required.25 x 3 mm Copper strip

32

570

18240

... More
53 12.57 Vol 6 - Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.

3

4256

12768

... More
ESR 32.02 Vol 6 - Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 Part-1 or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms Max as per IS-3975. 2 core 10 sq mm

0.18

79232

14261.76

... More
ESR 32.05 Vol 6 - Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 Part-1 or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms Max as per IS-3975. 4 core 16 sq mm

0.16

141842

22694.72

... More
ESR 32.11 Vol 6 - Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 Part-1 or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms Max as per IS-3975. 3.5 core 50sq mm

0.22

178973

39374.06

... More
ESR 21.05 Vol 6 - Laying of LT cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. 2.5 to 25 Sqmm

0.32

20886

6683.52

... More
ESR 21.06 Vol 6 - Laying of LT cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. 35 to 95 Sqmm

0.22

31139

6850.58

... More
CSR 6 1.6.1 Vol 1 - Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth excluding rock in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usageand other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m

105

484

50820

... More
ESR 63.04 Vol 6 - Supplying and fixing of heavy duty Brass Cable Gland. 45 mm dia

8

197

1576

... More
44 11.7.1 Vol 6 - Street Light: Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light output. Rated life Burning Hrs 50000 hr@ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment and impact resistance of complete luminaire IK08. Power Factor0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40 mm to 50 mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB LED Efficiency130 lm/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL/CPRI and any Government certified agency and Design and Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and Cree/Nichia/ Lumileds/Osram make LED Source. LED Post Top Lantern with 25 W for gate

2

6922

13844

... More
45 11.8.3 Vol 6 - Supply of 70 watts LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment and impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI and any Government certified agency and Design and Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and Cree/Nichia/ Lumileds/Osram make LED Source.-LED Streetlight 70W

8

5992

47936

... More
55 13.1.1 Vol 6 - Supplying and Fixing of mm dia class A GI pipe bracket upto 2ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires.Using 25mm dia G.I.Pipe

8

978

7824

... More
10 4.2.7 Vol 6 - Fabricating, supplying and erection of 9 mtr long hot dip Galvanized Octagonal hot dip Pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for .......m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm , top.... mm with 3 mm thick, suitable base plate and 4Nos of ..... long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc., excluding foundation as per drawing appended.9 m - Top 70 mm and Bottom 155 mm dia

2

19500

39000

... More
45 11.9.2 Vol 6 - Supply of LED floodlight 100Watts luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection mouldedpolycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment and impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm.Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power onsumption. LED Efficiency 1301m/w, nominal CRI 75.Luminaire manufacturer should have in- house facility accredited by NABL /CPRI and any Government certified agency and Design and Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warrantyof 2 Years against any manufacturing defect working under tandard electrical conditions as mentioned above should be given byLED manufacturer and Cree/Nichia/ Lumileds/Osram make LED Source.LED Floodlight 100W

8

9486

75888

... More
12 4.6.4 Vol 6 - Supplying, and fixing of Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete.Double Arm Bracket with 1000 mm Standard 40/50 mm dia

2

2700

5400

... More
20 5.47 Vol 6 - Supplying and fixing Microprocessor based Electronic timer without contactor, Din Mounting using necessary bolts, nuts and washers etc.,. 3-120sec setting.

2

2315

4630

... More
15 5.14.1 Vol 6 - Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947.22/25 A

2

2210

4420

... More
19 5.43.1 Vol 6 - Supply and Installation / Fixing / Provision of Pole box with HRC Fuse / MCB provision and suitable connector / terminal for 3 Ph/ 1 Ph connections with Loop-In and Loop- Out terminals for 10 mm2 /25 mm2 3.5 C AI/Ar/Cu/Ar Cable and branch out 2.5 mm2 2 core AI/Cu PVC Insulated cable, enclosed in a Thermoplastic, Polystyrene enclosure, which should be shock proof, safe,IP65Weather Proof, rust proof, dust proof, water proof having Internally Embedded Gasket with provision for cable entry through IP65 Thermoplastic, polyamide glands and/or grommets-200 mm x 200 mm x 98 mm

2

2300

4600

... More
CSR 157 13.40.1 Vol 5 - Pump Set: Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments.2 HP, Size 65x50 Head 13M, Discharge 462 LPM

1

15610

15610

... More
CSR 157 13.40.3 Vol 5 - Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments.3 HP, size 50x40 Head 30M, Discharge 198 LPM

1

18816

18816

... More
CSR 152 13.13.6 Vol 5 - Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl and Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. 5.00 HP - 90 LPM @ 110 m = 15 STG Outlet Dia - 2.00"etc. complete

1

32137

32137

... More
6 2.6.1 Vol 6 - Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990. 3C x 2.5 sq mm

40

117

4680

... More
6 2.6.2 Vol 6 - Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990. 3C x 4 sq mm

160

168

26880

... More
CSR 98 9.5.1 Vol 5 - Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete Contractor will make his own arrangements for procuring water for testing etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 16.0-63mm dia

145

327

47415

... More
155 13.23.1 Vol 5 - Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current and dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1 DOL- Direct Online Starter Upto 3 HP pumps

2

6500

13000

... More
155 13.23.2 Vol 5 - Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current and dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1 DOL- Direct Online Starter above 3 to 6 HP pumps

1

9550

9550

... More
CSR 154 13.24.1 Vol 5 - Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments 50 mm dia.

2

1250

2500

... More
CSR 154 13.25.1 Vol 5 - Supply and delivery at site of brand new best makeNon -return valve as per IS 778/1984 with ISI Mark and as per its latest amendments 50 mm dia.

2

1250

2500

... More
BSR 18 19 41.10 - External Electrification: Supplying and fixing M.S rectangular pole made of 2 equal angles 65 x 65 x 6 mm welded together and fixed in C.C 1:2:4 with 2 nos 16 mm dia MS . Hold fast rods each of length 25cms. Including cost of all materials cutting, bending scaffolding wherever neccessary, nicely finishing the welded joints with all lead lifts and as per the directions of the engineer-in-charge of the work and including providing 2 coats of approved quality paint over one coat of shop painting excluding cost of earthwork and concrete including cost of materials, labour, HOM complete as per specifications.

36

859

30924

... More
CSR 95 11.58 Vol 2 - Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineerin- charge. Made of G.I. wire of dia 4 mm

28

803

22484

... More
CSR 15 2.1.6 Vol 1 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates

0.5

6243

3121.5

... More
19 5.41.1 Vol 6 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint-40 x 40 x 6 mm

22

305

6710

... More
ESR 13.01 Vol 6 - Distribution Transformer - 3 Phase,11kV/433V - Amorphous Core with Oil as per IS-1180 Part-1: 2014 OPEN BUSHING TYPE 25 kVA, Aluminium Wdg, Star 2 5 Star

1

106779

106779

... More
ESR 18.01 Vol 6 - LT Distribution Box for 100 kVA DTC with MCCB's Sheet Metal Dwg No. BESCOM/GM/QSandS/58 Dtd 24.11.2018

1

22686

22686

... More
ESR 17.01 Vol 6 - LT Protection kit Dwg No. BESCOM/GM/QSandS/10 Dtd 24.11.2018

1

2023

2023

... More
ESR 21.08 Vol 6 - Double Pole TC Sets for erection of Transformers on RCC/PSCC 9 Mtrs Long Poles as per IS-1977, For 100/300kVA 4/5 Star Rated Transformers using 9 mtr RCC Pole 145Kg WL - GI

1

30694

30694

... More
ESR 24.01 Vol 6 - GOS as per IS-9921, IS-1977 11kV, 200 Amps Single Break GOS Dwg No. BESCOM/GM/QSandS/23 Dtd 24.11.2018

1

9450

9450

... More
ESR 25.01 Vol 6 - DOLO Cutouts as per IS-9385, Part-1 to 3, 11kV DOLO Cutouts Conventional to Erstwhile KEB Specification Dwg No. BESCOM/GM/QSandS/20 Dtd 24.11.2018

1

5875

5875

... More
ESR 1.01 Vol 6 - RCC Pole - 9 Mtr Long, 150 Kg WL Sq Section Dwg No. BESCOM/GM/QSandS/51 Dtd 24.11.2018 as per IS-785

2

7076

14152

... More
ESR 1.06 Vol 6 - PSCC Pole - 9 Mtr Long, 200 Kg WL Dwg No.Dwg No. BESCOM/GM/QSandS/50 Dtd 24.11.2018 as per REC Standards

5

4199

20995

... More
ESR2.02 Vol 6 - Cross Arms MS and GI as per IS-1977 11kV Horizontal X Arms - Galvanised Iron GI

7

487

3409

... More
ESR 2.03 Vol 6 - Cross Arms MS and GI as per IS-1977 11kV Special 3 Pin X Arm - MS Dwg No. BESCOM/GM/QSandS/03 Dtd 24.11.2018

1

879

879

... More
ESR 2.12 Vol 6 - HT ST Support 50x6mm Flat - GI

6

121

726

... More
ESR 6.06 Vol 6 - 11kV, 5KN Composite/Polymeric Pin Insulator 24mm dia FRP Rod

21

205

4305

... More
ESR 6.10 Vol 6 - 11kV, 45kN Polymeric Insulator

6

186

1116

... More
ESR 24.a Vol 6 - Guy set complete with No.15 strain insulator and Cocreting matrials

4

593

2372

... More
ESR 5.10 Vol 6 - Fixing of GUY Set with break insulator making use of 7/3.15 mm 7/10 SWG galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. Excluding excavation of PIT

4

266

1064

... More
ESR 7.02 Vol 6 - Rabbit ACSR6/3.35 mm Al + 1/3.35 mm St, Std Wt: 214 Kg/KM

1.4

46234

64727.6

... More
ESR 2.16 Vol 6 - Spiral Earth Electrode

10

239

2390

... More
ESR 2.15 Vol 6 - EG Stirrup MS with GI wire lacing

10

276

2760

... More
ESR 68.17 Vol 6 - Caution/Danger Board

4

150

600

... More
ESR 4.02 Vol 6 - Anti climbing device GI Barbed wire 12mtrs/Kg

4

89

356

... More
DGS & D Rates - Solar Street Light System With Mounting Structure and Pole MNES Specification Description of item: 2 X 18 W LED ,PV Module: 120 W,Battery Capacity: 12 V ,100 AH

6

34231

205386

... More
NSR - Supplying and fixing Industrial bell

1

8000

8000

... More
CSR 247 21.1.1 Vol 5 - Water purification plants: Providing, Installation and Commissioning of automatic Water purification plant RO+UF with all accessories piping, product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. Ref- detailed specification enclosed seperatly. Note:- 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BSI /NFS standards,with BSI / NFS mark . 3. Tenders to be invited for procurement. 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note : Refer the ANNEXURE : F for Detailed Specification of Each components-For 25 LPH : Cabin Type

1

25000

25000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.