Karnataka State Police Housing And Infrastructure Development Corporation Limited Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Karnataka State Police Housing And Infrastructure Development Corporation Limited - KSPHCL Tender

Works
Civil And Construction
Building Construction
Opening Date12 Nov 2024
Closing Date13 Dec 2024
Tender Amount₹ 2,22,07,834.79 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
1.3.2 - Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25mm dia 2mm thick

150

78

11700

... More
2.3.2 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010. 1) 1.5 Sqmm

650

26

16900

... More
2.3.3 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1) 2.5 Sqmm

1050

42

44100

... More
2.3.4 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1) 4 Sqmm

350

63

22050

... More
2.3.5 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1) 6 Sqmm

100

92

9200

... More
2.2.1 - Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point up to 3Mtr from tapping point to out let via switch

5

269

1345

... More
2.2.2 - Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet Medium point above 3mtr up to 6Mtr from tapping point to out let via switch

40

379

15160

... More
2.2.3 - Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet Above 6Mtr up to 10Mtr from tapping Point to out let via switch

50

555

27750

... More
Ele 14-15 4.2 - Supplying and fixing PBBC bakelite straight or slant batten holder and wiring, within 60w/230 Volts lamps. Make - Group "A" materials and as per the directions of Engineer in charge of the work.

50

88

4400

... More
3.4.2 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3 way

25

159

3975

... More
3.4.3 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5 way

20

177

3540

... More
3.4.4 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6 way

20

220

4400

... More
3.4.5 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 way

6

261

1566

... More
3.4.6 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12 way

12

319

3828

... More
3.5.2 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. iv) 1-3 Module

25

161

4025

... More
3.5.3 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. iv) 4 Module

20

175

3500

... More
3.5.4 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. iv) 6 Module

20

234

4680

... More
3.5.5 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. iv) 8 Module

6

284

1704

... More
3.5.6 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. v) 10 - 12 Module

12

344

4128

... More
3.6.1 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 and as per the directions of Engineer in charge of the work. i) 6 Amps one way switch

130

102

13260

... More
3.6.7 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 . and as per the directions of Engineer in charge of the work. iv) b) 16 Amps one way switch

8

180

1440

... More
3.6.3 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. and as per the directions of Engineer in charge of the work. ii) 6 Amps 3 way socket

40

171

6840

... More
3.6.10 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 as per the directions of Engineer in charge of the work. ii) 16 Amp Universal socket

4

236

944

... More
3.6.4 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. as per the directions of Engineer in charge of the work. ii) Stepped fan regulator two module

12

357

4284

... More
3.6.12 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 as per the directions of Engineer in charge of the work. l) RJ45/I.O. outlet

12

337

4044

... More
Approved rates Alur fire station - Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Make - Group "A" materials and as per the directions of Engineer in charge of the work. l) RJ 11

2

250

500

... More
11.3.3 - Supplying of .feet -PVC Batten with integrated LED tube . W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.1 x 4' - 36/40

25

1269

31725

... More
11.3.2 - Supplying of .feet -PVC Batten with integrated LED tube . W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.1 x 4' - 20/22 W

15

690

10350

... More
11.6.3 - Supplying of recess mounting non integral type . LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition LED modular down light 2'x2' 36 W

9

4553

40977

... More
13.7.1 - Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076 twin twisted PVC insulated wires, required Nos of round blocks and clamps. .a) On wall/ceiling/Rafter/Girders

49

122

5978

... More
6.3.1 - Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48"" Sweep (1200 mm) Regular model.

13

2984

38792

... More
6.5.1 - Supplying wall mounting fan suitable to operate at single-phase 230 V A.C. supply, 300mm Sweep

2

2492

4984

... More
13.10 - Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring

15

171

2565

... More
6.1 - Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply

4

1492

5968

... More
13.14 - Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire

4

492

1968

... More
12.56 - Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia

4

3510

14040

... More
12.57 - Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.

6

4256

25536

... More
12.58.2 - Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required GI strip 25X3mm

50

82

4100

... More
12.58.7 - Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm Copper strip

10

570

5700

... More
12.58.11 - Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate

6

7421

44526

... More
Ele SR 19-20 6.18.3 - Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wire

50

19

950

... More
5.42.2 - Fabricating supplying and mounting MS box made out .SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.

110000

-

47300

... More
5.41.1 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. . 40x40x6mm

8

305

2440

... More
5.40.2 - Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 30 x 10 mm Aluminium Strips

1.5

3435

5152.5

... More
5.38 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C 50Hz 12/24v D.C.

3

515

1545

... More
5.29 - Supplying, fixing and wiring 3 phase Digital Ammeter/ Voltmeter

2

1425

2850

... More
5.21 - Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.

1

9255

9255

... More
5.20.8 - Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board.32-40 Amps 4 pole

2

5147

10294

... More
5.15.11 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE 160Amps 25kA

1

13447

13447

... More
5.15.9 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE 100aMPS 25kA.

4

8487

33948

... More
5.11.3 - Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. (Open Execution) 125 Amps

2

10326

20652

... More
5.18.1 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC60898 6-32Amps SP

10

415

4150

... More
5.18.4 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC. 6-32Amps DP

3

739

2217

... More
5.18.7 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 6-32Amps TPN

3

1717

5151

... More
5.19.11 - Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. Double Door 4 Way TP &N

3

4038

12114

... More
Approved rates Devanahalli fire station - Supplying and fixing Industrial bell

1

8000

8000

... More
11.8.3 - Supply of LED Streetlight70 watt luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall beEngraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source

4

5992

23968

... More
13.2.1 - Supplying and Fixing.mm dia clampsss A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires. Using 25mm dia G.I.pipe

4

1203

4812

... More
11.7.2 - Supply of LED pole mounting type post top lantern 25 watt with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light outputRated life Burning Hrs 50000 hr@ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/1 EC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.

3

7722

23166

... More
13.6 - Fixing charges of post top/ Gate/ Garden fitting /LED on the existing CI/ GI or any other pipe using required size of reducer, wiring using suitable wires.

3

198

594

... More
Bescom SR 23-24 32.05 - Supplying of 1.1 KV LT UG cable 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 16 Sqmm, 4 Core, (11 GI Strips - 4x 0.8 mm)

100

141

14184

... More
Bescom SR 23-24 32.09 - Supplying of 1.1 KV LT UG cable 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 35 Sqmm, 3.5 Core, (12 GI Strips - 4 x0.8 mm)

150

154

23109

... More
Bescom SR 23-24 21.06 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 35 to 95 Sqmm

150

31

4669.5

... More
Ele SR 19-20 6.6.1 - Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7) In soil (ordinary)

160

76

12160

... More
Ele SR 14-15 7.20.4 - Supply and laying double walled corrugated (DWC) HDPE Pipe including all necessary connecting Sockets/Couplings/Tees/ Bends/ End-caps of same materials in exisiting trench as per IS 14930 part -II suitable for drawing under ground cables.63mm OD / 50mm ID

170

261

44370

... More
Ele SR 14-15 7.20.1 - Supply and laying double walled corrugated (DWC) HDPE Pipe including all necessary connecting Sockets/Couplings/Tees/Bends/End-caps of same materials in exisiting trench as per IS 14930 part -II suitable for drawing under ground cables.40mm OD / 32mm ID

90

98

8820

... More
Ele SR 19-20 6.9.1 - Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV.) 40mm

10

335

3350

... More
9.3.2 - Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 3 kVA ON LINE UPS

2

38719

77438

... More
9.5.5 - Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 60 /65 AH capacity

16

6413

102608

... More
6.22 - Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries.

2

4807

9614

... More
8.1 - LAN networking: Supplying and drawing UTP-CAT 6E LAN cable.

400

38

15200

... More
8.4.2 - Supplying & Fixing of switch mounting rack with power manager & Cable manager. 6U with 450mm depth

1

6977

6977

... More
8.9.5 - Supplying fixing of Network Switches 24 Port 10/100 Switch

1

4700

4700

... More
8.10.2 - Supplying & Fixing of I/O Socket with back box Double I/o

12

550

6600

... More
8.11.2 - Supplying & fixing of 2 mtrs. Cat 6Patch Cable. 2Mtr

12

257

3084

... More
8.12.2 - Supplying & Fixing of Patch panel for Lan Cabling. 24 Port 10/100 Patch Panel

1

4100

4100

... More
Civil SR 18-19 Pg-XLVII 4 - Pump sets : Supply, Installing fixing, testing and commissioning of Vertical/ Horizontal multistage 3 phase 5 HP Mono submersible pumpset, of adequate HP, capable of giving a required discharge at suitable head,to 'work on 3 Ph 50 Hz, 400/440V with necessary gate valve, NRV , unions,flanges in 1:2:4 etc., complete with wiring fromTPN switch to control panel and to the pumps etc. complete.

1

22230

22230

... More
5.01 - Pump sets : Supply, Installing fixing, testing and commissioning of Vertical/ Horizontal multistage 3 phase 5 HP Mono submersible pumpset, of adequate HP, capable of giving a required discharge at suitable head,to 'work on 3 Ph 50 Hz, 400/440V with necessary gate valve, NRV , unions,flanges in 1:2:4 etc., complete with wiring fromTPN switch to control panel and to the pumps etc. complete.

1

8500

8500

... More
5.1 - Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 V 1/3 phase motor upto 5 HP

2

1927

3854

... More
Approved rates PG 2025 - Fixing charges of pumpset after aligning, leveling & assembling etc, inclusive of transportation charges to work spot.

2

1000

2000

... More
Approved rates PG 2025 - Supplying of 50 mm kirloskar / other approved make CI screwed foot valve. Make- Using group "A" materials. And as per the directions of engineer incharge of the work.

2

450

900

... More
5.6.6 - Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws. 20"X20"x2.5

2

326

652.26

... More
Approved rates Senior IPS qtrs Jeevanbheem nagar - Supply of erection testing and commissioning of water level controller and connected accessoriers etc.

1

10000

10000

... More
Civil SR 21-22 P150G - Providing,supplying to work site, 7.50 HP 15 STG Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work

1

44012

44012

... More
Civil SR-2021-22 P250A - Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendment 50 mm dia nominal

1

1250

1250

... More
Civil SR-2021-22 P260A - Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendment size 50 mm

1

1275

1275

... More
Civil SR-2021-22 P280B - Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL Direct Online Starter 2) S-D- Star Delta Starter for outdoor 6 to 15 HP pumps

1

16500

16500

... More
KUWSS&DB. (page 1) - Erection of panel and Meter Board : Erection of combined panel board and meter board unit with necessary materials and labour charges Including providing cement concrete foundation bed etc complete.

1

369

369

... More
KUWSS&DB. - Erection, Electrification and commissioning Work of Pump Sets : eraction of pumpset including aligning and balancing with all necessary erection materials and labour including supply and erection of two pair of supporting clamps, bore-well, cap, cable protector bolts, nuts, valve and gauges ect.,

1

1478

1478

... More
2.6.3 - Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 and as per the directions of Engineer in charge of the work. 3C x 6 mm

250

245

61250

... More
Civil SR-2018-19 Pg-92 13.15 - KSRB13-3.1: Providing and fixing in trenches galvanised / mild steel tubes (medium grade) nominal bore with all fittings (earth work in trenches to be measured and paid for separately) including cost of all materials, labour charges, HOM and testing complete as per specifications. Specification No.KBS 50 mm dia

180

388

69840

... More
2.5.4 - Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 6C x 1.5 mm2

60

121

7260

... More
Bescom SR 2023-24 13.02 - Supplying & erection of Star rated 63 KVA transformer center 11kV/433V, 9 mtr RCC DP Transformer Structure with 9 mtr long RCC pole complete set materials like angle iron, bedding channels, belting cross arms bracess, round clamps etc.,(as per BESCOM SR 2021-22) and wiring with suitable capacity LT Lead wires, earthing 3 nos, forming transformer structure including transformer and labour charges and maintanence of one year or as per current KPTCL norms.Obtaining Govt.electrical inspectorate approval, charging and handing over to BESCOM in full manner. Make - ESCOM approved makes

1

269371

269371

... More
Bescom SR 21-22 4.06 - Construction of platform with size stone, cement concert for erection of 500 kVA Transformer/Metering cubicle/Heavy Equipment. Construction of platform (1.5x1.5x1.2) Mtr in size stone, for erection of transformers/ Heavy equipment including all materials, labour. Excavation of (1.5x1.5x1) Mtr pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 10 cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9 Mtr below ground level and 1.2 Mtr above ground level neatly hammer dressed in cement morter 1:6. Providing and Laying cement concrete slab 1.5x1.5x0.10 Mtr withcement concrete of 1:2:4 mix forming & cutting complete, providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completely

1

30361

30361

... More
Bescom SR 2023-24 24.01 - 11 kV, 200 Amps Single Break GOS (Dwg No. BESCOM/GM/QS&S/23 Dtd 24.11.2018)

1

9450

9450

... More
Bescom SR 2023-24 24.07 - H - Frame Set for fixing 11 kV, 200 Amps Single Break GOS - (For DP structure for providing New GOS for sectionalisation) - G

1

6071

6071

... More
Bescom SR 23-24 68.17 - Supplying & Fixing of Caution/Danger Board

3

150

450

... More
Civil SR-18-19 37.2 - Supplying and fixing M.S. Rectangular poles made out of 2 equal angles of 65x65x6 mm welded together and fixed in CC (1:2:4) WITH 2 NOS 16mm dia M.S. hold fast rods each of length 25 cms. Including cost of all materials cutting, bending scaffolding wherever necessary, nicely finishing the welded joints with all lead lifts and as per the directions of the Engineer-in - charge of the work and including providing 2 coats of approved quality paint over one coat of shop painting ( excluding cost of earthwork and concrete) including cost of materials, labour, HOM complete as per specifications

30

859

25770

... More
Bescom SR 21-22 38 - Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be welded to the Pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint

40

987

39480

... More
Civil SR - Providing and spreading jelly-40mm size for transformer yard-(15'x20'-150mm) etc complete as per directions of engineer in charge of the work

3

1000

3000

... More
5.41.1 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron… and M S flat ……. With bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint, 40x40x6mm as per the directions of the engineer in charge of the work.

42

305

12810

... More
Bescom SR 2023-24 1.01 - RCC Pole - 9 Mtr Long, 145 Kg WL (Dwg No. BESCOM/GM/QS&S/02 Dtd 24.11.2018) as per IS-785

8

7076

56608

... More
Bescom SR 2023-24 7.02 - ACSR Conductor as per IS-398 (Part - 2/1996) Rabbit ACSR (6/3.35 mm Al + 1/3.35 mm St), Std Wt: 214 Kg/KM

0.8

46234

36987.2

... More
Bescom SR 2023-24 2.02 - Erection of RCC/PSCC Pole of 9 to 10 Mtr long in a pit of 1.8 Mtr depth

8

1113

8904

... More
Bescom SR 2023-24 7.02 - Stringing of Conductor (including pin binding, providing jumps, dead ending, etc.,) for Rabbit ACSR

0.8

5233

4186.4

... More
Bescom SR 2023-24 2.05 - Supplying & fixing LT 4 Pin Cross Arm - MS (Dwg No. BESCOM/GM/QS&S/32 Dtd 24.11.2018)

2

289

578

... More
Bescom SR 2023-24 2.01 - Supplying & fixing 11 kV, Horizontal Cross Arm - Mild Steel (MS) (Dwg No. BESCOM/GM/QS&S/04 Dtd 24.11.2018)

4

372

1488

... More
Bescom SR 2023-24 5.10 - Fixing of GUY Set with break insulator making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT)

2

266

532

... More
10.1.1 - Supplying, installing, testing and commissioning of Diesel Generator 15 KVA set with following specifications. Power rating as per standard reference condition as per-BS 5514/ISO 3046/ ISO 8528 & IS 1002/ISO 3046 Generator set specifications. Engine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade), Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation

1

349110

349110

... More
10.2.1 - Supply, Erection, testing and commissioning of AMF panel suitable for .15.kVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .A 4 pole contactor for alternator with thermal O/L relay,. A 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, .capacity bypass switch and frequency sensing, PCC 1301controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ kVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMF module by pass Mode, Battery charger unit with inbuilt Auto/Manual and Flat/ Boost facility. The complete set shall have sufficient safety and adhere to NEC, NBC 2016, IEC, CPWD specifications, PCB norms and KSGEI Acts and Rules.

1

58711

58711

... More
APPD Rates COP Nirbhaya - DG Set foundation 3x2x1.5 mtr for 15 KVA DG set as per direction of engineer incharge

1

29411

29411.76

... More
APPD Rates COP Nirbhaya - Exhaust System : Supply, receive at site, store, unpack, assemble and connect exhaust pipe with Class B MS pipe with flanges, fire fly gaskets, hardware, glass wool and aluminium sheet cladding etc., as per specification inclusive of all structural supports etc., complete as required. Individual Exhaust pipe including flexibles from set with glass wool and Alu. clading etc., as required complete for up to 62.5KVA DG set (diameter of the pipe shall be specified by the vendor) as per BESCOM norms.

10

2400

24000

... More
APPD Rates COP Nirbhaya - Silencer with painting glass wool insulation / Al. clading etc., as required complete for 15 KVA DG set

1

2899

2899.2

... More
APPD Rates COP Nirbhaya - PVC insulated, steel armoured 1100 V Grade Copper Conductor cables. c) 12C x 2.5 sq.mm (YFY).

1

432

432

... More
NSR - Supplying and fixing Lightining arester spike as per the directions of Engineer in charge of the work. - as per directions of engineer incharge of work.

1

5000

5000

... More
NSR - Supplying and Fixing Solar street light system with mounting structure &6 Mtr pole description of item 2X18 W, PV module: 80 W, battery capacity: 12V, 24 AH as per the directions of engineer incharge of the work. - as per directions of engineer in charge of work.

4

41161

164644



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.