Karnataka State Akkamahadevi Womens University Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Karnataka State Akkamahadevi Womens University - AWUV Tender

Civil And Construction
Building Construction
Opening Date4 Jul 2024
Closing Date7 Aug 2024
Tender Amount₹ 3,07,25,111.55 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
004 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Staircase waist Slab (Vol 1, Pg.no.16, Item no. 2.5.1)

8

9945

79560

... More
005 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Beam (Vol 1, Pg.no.16, Item no. 2.5.2)

73.56

10608

780324.48

... More
006 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Slab (Vol 1, Pg.no.16, Item no. 2.5.3)

244.06

9945

2427176.7

... More
007 - Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in Superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (Vol 2, Pg.no.14, Item no. 6.8)

400

7969

3187600

... More
008 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (Vol 1, Pg.no.14, Item no. 2.11(a))

76

89457

6798732

... More
009 - Providing and fixing in position Mathi/Nandi wood half panelled shutters at bottom and half glazed at top for window shutters with stiles and rails of 35mm thick, 75mm wide in two halves with panels of 25mm thick, 3mm thick reeded glass for top panels fixed with wooden beading including cost of materials, labour charges, usage charges complete as per specifications. (excluding cost of fixtures) (Vol 2, Pg.no.102, Item no. 12.37)

58.65

6456

378644.4

... More
010 - Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (Vol 2, Pg.no.99, Item no. 12.11)

2.06

138074

284432.44

... More
011 - Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with both side prelam (Vol 2, Pg.no.104, Item no. 12.55.1)

24.36

2366

57635.76

... More
012 - Providing and fixing of bright finished brass quality fixtures to the doors such as aldrop, handle, latches tower bolt etc… including labour charges complete as per the direction of the Engineer in charge (MR)

30

3000

90000

... More
013 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding (Vol 2, Pg.no.86, Item no. 11.34A)

2800

168

470400

... More
014 - Providing and fixing 304 - grade stainless steel hand rails of 14-gauge pipes for Ramps or Staircase are made out of stainless steel hallow pipes, using 50mm dia for verticals @1.60 mtr c/c are fixed to the ramps or steps by drilling with bolts and 100mm dia MS base plates 10mm gauge for fixing of Vertical pipes 4 - Nos anchor bolts & 40mm dia pipes are fixed horizontally for 2-rows top, one pipes are fixed with vertical pipes another one are fixed with elbows and 25mm dia pipes are fixed horizontally for 2-rows below top measure @ equal intervals including cutting, welding, bending wherever necessary with suitable caps @ tops, bottoms & corners finishing with mat / shining etc., complete including cost and conveyance of all materials, labour for all items of work, HOM of equipment with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. Ramps or Staircase for physically challenged. (MR)

66

5700

376200

... More
015 - Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineering-charge. (Vol 2, Pg.no.42, Item no. 8.6.1)

4600

323

1485800

... More
016 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Vol 2, Pg.no.42, Item no. 8.9)

3070

385

1181950

... More
017 - Providing and laying Vitrified tiles with thickness 9-10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, Including Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm (Vol 2, Pg.no.62, Item no. 9.21.2)

1985.35

1447

2872801.45

... More
018 - Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete. (Vol 2, Pg.no.60, Item no. 9.10)

225

1106

248850

... More
019 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Vol 2, Pg.no.50, Item no. 8.51)

4400

100

440000

... More
020 - Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge. (Vol 2, Pg.no.51, Item no. 8.55.2)

4400

53

233200

... More
021 - Wall painting with premium acrylic emulsion paint of interior grade,having VOC (Volatile Organic ompound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. (Vol 2, Pg.no.50, Item no. 8.54.2)

4400

110

484000

... More
022 - Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Vol 2, Pg.no.45, Item no. 8.27)

2690

53

142570

... More
023 - Finishing walls with Premium Acrylic Smooth exterior paint of required shade : Old work (Two coats applied @ 1.43 l/ 10 m²) over existing cement paint surface including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Vol 2, Pg.no.53, Item no. 8.75.1)

4950

111

549450

... More
024 - KSRB 7.11 : Providing and fixing in position aluminium windows and ventilators as per approved drawings with sliding shutters using three track window frame of size 92x31.75mm bottom section 1.3mm thick, weight 1.07kg/m; sides and top sections 1.3 mm, thick, weight 0.933 kg/m.shutter frame section comprising top and bottom section of size 40mmx18mm, wall thickness 1.25mm. weight 0.417 kg./m. shutter side outer 40mmx18mm. wall thickness 1.25mm. weight 0.417 kg/m, shutter interlock section 40mmx26.7mm wall thickness 1.1 mm. thick, weight 0.469 kg/m, the shutters mounted on nylon rollers with approved quality of fixtures such as aluminium handles tower bolts etc.; providing and fixing 5.5mm. thick plain glass for shutters fitted with rubber beading all aluminium sections including cutting to required length, joints mitred subdividing the frame tenonned and rivetted, in the assembled frame, stiffened with end clips for corners, angles etc., and fixed to the walls, lintels, floor beams/cills as the case may be, with necessary steel screws, raul plugs or teak wood gatties including cutting masonry or concrete and making good the original surface using cement mortar. using aluminium section powdered coated to a minimum of 60-70 microns with exterior durable pure polyester grade powder of approved quality. (MR)

165.15

4741

783042.21

... More
025 - KSRB 7.14 : Providing, fabricating, assembling and fixing in position aluminium partitions using sections in combination of plain, single grove and double grove as per requirements for the frames of overall size 101.6mm x 44.45mm, 3.18mm.thick having section weight, plain sections 2.40kg/m single grove section 2.541kg/m. and double grovesection 2.683 kg/m and bottom 46 kg/m; aluminium louvres of size 77.6mmx27.6mm 1.7mm. thick section weight 0.483kg/m; bottom portions provided with 12mm. thick prelaminated sheet both side of approved colour lamination exterior grade; aluminium sections of mat finish or glossy finish using section, spacing of vertical member shall not exceed 0.6 m. c to c; sections are cut to the required lengths, joints mitered and corners grinded subdividing frames tennoned and rivetted to the frames, the assembled frame should be stiffened with corner angles stripped and fixed with screws, rawl plugs and teak wood gutties to R.C.C.columns or masonry on sides, R.C.C. lintels or beams at top and floor at bottom, including cutting chistling and making good with cement mortar to match the surface, providing and fixing bottom panel filled with the materials to a height of 0.9m. from floor level; and 5.5mm. thick plain glass for middle portion viz., 0.9m. to 2.13 m. and top panel with lower sections, the glass and panels fitted with glazing clips of 19mmx17.3mm. with thickness of 0.9mm. weight 0.124kg/m; aluminium sections pre-treated for removal of any rust and prevention of further rust formation, and coated with greasy materials for non-adherence of mortars or any other sticky materials; vertical members embedded in the flooring by making suitable size holes and fixing with cement mortar, with necessary opening for fixing of doors of standard size (excluding cost of door opening) All the frame should be throughly cleaned free from rust, scale or dirt including cost of materials, fixtures, labour and HOM of machinery complete as per specifications. using aluminium section powdered coated to a minimum of 60-70 microns with exterior durable pure polyester grade powder of approved quality. (MR)

5.04

5082

25616.808

... More
026 - KSRB 7.17 : Providing, fabricating, assembling and fixing in position aluminium doors using following aluminium mat finish or glossy finish, outer frame plain section 101.6x44.45mm thickness 3.18mm, section weight 2.404 kg/m, door shutters vertical section 44.62x44.45mm thickness 3.18mm, section weight 1.505kg/m, top section 47.62x44.45mm thickness 3.00mm, section weight 1.426kg/m bottom section 114.3x44.45 thickness 3.18mm, section weight 2.646kg/m, door central section 49.91x44.45mm thickness 3.00mm, section weight 1.495 kg/m glazing clips 19x17.3x11mm thickness 0.9mm section weight 0.124kg/m; aluminium sections cut to length joint metred cornersgrinded, the shutters pivoted opening arrangement with heavy duty aluminium alloy automatic door closures floor mounted, providing and fixing standard approved accessories, such as aluminium handle for full width or length, tower bolts, lock, pivots: P.V.C. or rubber gasket with 5.5m. thick plain glass for top and bottom panel; aluminium sections treated for removal of any rust and prevention of further rust formation, and coated with greasy materials for non-adherance of mortars or any other sticky materials; the assembled frame fitted with the corner angles, strips and fitted with screws, rawl plugs or teakwood gutties to R.C.C. columns or masonry on sides. beams and flooring in bottom. including cutting, chistling and making good with cement mortar to match the surface; all the frames throughly cleaned free from rust, scale, or dirt including cost of materials, fixtures, labour and HOM of machinery complete as per specifications. using aluminium section powdered coated to a minimum of 60-70 microns with exterior durable pure polyester grade powder of approved quality. (MR)

3.78

6593

24922.296

... More
027 - KSRB 7.10 : Providing and fixing in position aluminium windows and ventilators as per approved drawings with sliding shutters using double track window frame section of size 61.85x31.75mm. with 1.2mm thick, bottom section weight 0.695 kg/m, sides and top sections 1.3 mm. thick weight 0.659 kg/m; and shutter comprising top and bottom section of size 40mmx18mm, 1.25mm thick 0.417 kg./m; shutter outer side 40mmx18mm, 1.25mm.thick weight 0.417 kg/m, shutter interlock section 40mmx26.7mm, 1.1mm thick, weight 0.469 kg/m. the shutters mounted on nylon rollers with approved quality of fixtures such as aluminium handles tower bolts etc.; and providing and fixing 5.5mm. thick plain glass for shutters fitted with rubber beading aluminium sections including cutting to required length, joints mitred subdividing the frame tenonned and rivetted in the assembled frame stiffened with end clips at corners angles etc., and fixed to the walls, lintels, floor beams/cills as the case may be with necessary steel screws, raul plugs, or teak wood gatties including cutting masonry or concrete and making good the original surface using cement mortar, aluminium sections pretreated for removal of any Specification No. KBS using aluminium section powdered coated to a minimum of 60-70 microns with exterior durable pure polyester grade powder of approved quality. (MR)

4.32

4637

20034

... More
028 - Providing and laying flooring and steps machine cut granite slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specifications. (Vol 2, Pg.no.63, Item no. 9.28)

230

4279

984170

... More
029 - Providing and laying Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) Light shade pigment using white cement (Vol 2, Pg.no.59, Item no. 9.6.1)

75

1269

95175

... More
030 - Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Vol 2, Pg.no.47, Item no. 8.33.3)

330

139

45870

... More
031 - French spirit polishing :Two coats on new works including a coat of wood filler to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Vol 2, Pg.no.49, Item no. 8.46)

152.49

295

44984.55

... More
032 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Coping (Vol 1, Pg.no.15, Item no. 2.1.3)

5

6630

33150

... More
033 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Column - Double Height (Vol 1, Pg.no.16, Item no. 2.5.1)

2

15912

31824

... More
034 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Beam - Double Height (Vol 1, Pg.no.16, Item no. 2.5.1)

15

14586

218790

... More
035 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Slab - Double Height (Vol 1, Pg.no.16, Item no. 2.5.1)

22.5

13260

298350

... More
036 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (Vol 1, Pg.no.14, Item no. 2.11(a)

4

89457

357828

... More
037 - KSRB 10-3: Providing and laying integral cement based waterproofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces consisting of following application. (a) Applying and grouting a slurry coat of neat cement using 2.75 kgl sqm of cement admixed with proprietary water proofing compound conforming to 18:2645 over the RCC slab after cleaning the before treatment. (b) Laying cement concrete using broken brick bats 25mm to 1OOmm size with 50% of cement mortar 1:5 admixed with proprietary water proofing compound 18:2645 20mm thick layer of cement 1:5 admixed with proprietary water proofing compound to required slope and treating similarly the adjoining walls up to 300mm height including off junctions of walls and slabs. (c) After two days of proper curing, applying a second coat of cement slurry admixed with proprietary water proofing compound (d) Finishing the surface with 20mm thick joint less cement of mix 1:4 admixed with water proofing compound and finally finishing the surface with trowel and neat cement and making of 300x300mm square. (e) the whole terrace so finished shall be flooded with water for minimum period of two weeks for curing and for final test including cost of materials complete as per specifications (MR)

2000

1102

2204400

... More
038 - Constructing brick masonry chamber for underground C.I. inspectionchamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 500X700 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets :With common burnt clay (non modular) bricks of class designation 3.5 (Vol 2, Pg.no.126, Item no. 13.54)

4

6278

25112

... More
039 - Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 lt low level white P.V.C. flushing including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (Vol 2, Pg.no.131, Item no. 14.11)

6

4884

29304

... More
040 - Providing and fixing white vitreous china pedestal type water closet European type with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend,overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid (Vol 2, Pg.no.131, Item no. 14.2.1)

4

4838

19352

... More
041 - Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps (Vol 2, Pg.no.132, Item no. 14.7.1)

10

3082

30820

... More
042 - Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 g (Vol 2, Pg.no.137, Item no. 14.39)

4

195

780

... More
043 - Providing and fixing Brass full way valve gate with C.I. wheel ofapproved quality (screwed end) : 25 mm nominal bore (Vol 2, Pg.no.117, Item no. 13.4.1)

10

549

5490

... More
044 - Providing and fixing Brass full way valve gate with C.I. wheel ofapproved quality (screwed end) : 32 mm nominal bore (Vol 2, Pg.no.117, Item no. 13.4.2)

10

598

5980

... More
045 - Providing and fixing brass stop cock of approved quality :20 mm nominal bore (Vol 2, Pg.no.117, Item no. 13.3.2)

20

305

6100

... More
046 - Providing and fixing brass stop cock of approved quality :15 mm nominal bore (Vol 2, Pg.no.117, Item no. 13.2.1)

10

286

2860

... More
047 - Providing and fixing PTMT pillar cock of approved quality and colour. 15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 g (Vol 2, Pg.no.120, Item no. 13.20.2)

10

314

3140

... More
048 - Providing and fixing PTMT grating of approved quality and colour. 100 mm nominal dia (Vol 2, Pg.no.120, Item no. 13.22.1.1)

12

41

492

... More
049 - Providing and fixing 100 mm sand cast iron grating for gully trap (Vol 2, Pg.no.136, Item no. 14.29)

12

47

564

... More
050 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 25mm dia, 10 kg/sqcm & class 5 (Vol 5, Pg.no.114, Item no. 10.1.1)

150

48

7200

... More
051 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 32mm dia, 10 kg/sqcm & class 5 (Vol 5, Pg.no.113, Item no. 10.1.2)

50

67

3350

... More
052 - Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for: Pipes of SN 4, 75mm dia. (Vol 5, Pg.no.114, Item no. 10.2.1)

40

217

8680

... More
053 - Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for: Pipes of SN 4, 110mm dia. (Vol 5, Pg.no.114, Item no. 10.2.2)

50

288

14400

... More
054 - Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 75 mm dia PVC BEND (Vol 5, Pg.no.118, Item no. 10.11.6)

20

245

4900

... More
055 - Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 110 mm dia PVC BEND (Vol 5, Pg.no.118, Item no. 10.11.8)

20

492

9840

... More
056 - Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 100 mm clamp (Vol 2, Pg.no.176, Item no. 17.10.1)

5

1777

8885

... More
057 - Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (Vol 2, Pg.no.123, Item no. 13.34)

4000

9

36000

... More
058 - KSRB 8.6-1 : Providing and fixing on wall surface 2.5 kg/sq.cm H.D.P.E. rain down water pipes of approved make and brand with necessary specials like shoes, bends and offsets fixed with iron clamps, wall plugs, screws, including cost of labour, complete as per specifications. 2.5 kg/sq.cm H.D.P.E. rain down water pipes 90 mm outer d (MR)

100

401

40150

... More
059 - Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. (Vol 2, Pg.no.187, Item no. 19.3)

11.81

2426

28651.06

... More
060 - Providing and fixing of GI sheet with tubuluar steel structure with the self driven screws, bolts including nuts and washers complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (MR)

445

125

55625

... More
061 - Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin- charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Vol 2, Pg.no.26, Item no. 7.38)

240

568

136320

... More
111 - Concealed Conduit System "Supplying heavy gauge PVC conduit pipe …….dia mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws." 19/20mm dia 2mm thick

50

69

3450

... More
112 - Concealed Conduit System "Supplying heavy gauge PVC conduit pipe …….dia mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws."25mm dia 2mm thick

50

81

4050

... More
113 - Concealed Conduit System "Supplying heavy gauge PVC conduit pipe …….dia mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.32mm dia 2.5mm thick

15

106

1590

... More
121 - Concealed Conduit System "Supplying heavy gauge PVC conduit pipe ……mm dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary"19/20mm dia 2mm thick

950

66

62700

... More
122 - Concealed Conduit System "Supplying heavy gauge PVC conduit pipe ……mm dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary"25mm dia 2mm thick

450

78

35100

... More
123 - upplying heavy gauge PVC conduit pipe ……mm dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary32mm dia 2.5mm thick

50

103

5150

... More
131 - Supplying heavy gauge PVC Conduit Pipe ….dia mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary." 19/20mm dia 2mm thick

185

68

12580

... More
132 - Supplying heavy gauge PVC Conduit Pipe ….dia mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary." 25mm dia 2mm thick

50

79

3950

... More
133 - Supplying heavy gauge PVC Conduit Pipe ….dia mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary." 32mm dia 2.5mm thick

15

99

1485

... More
151 - Supplying and fixing PVC/Metal conduit accessories."Deep junction boxes"Supplying and fixing PVC/metal conduitDeep Junction Box. P-2" a) 19/20 mm deep junction boxes

185

49

9065

... More
152 - Supplying and fixing PVC/Metal conduit accessories."Deep junction boxes"Supplying and fixing PVC/metal conduitDeep Junction Box. P-2"b) 25 mm deep junction boxes

75

56

4200

... More
153 - Supplying and fixing PVC/Metal conduit accessories.

15

61

915

... More
171 - Extra groove cutting in brick wall/CC floor to the suitable depth for concealing of conduit/GI pipe and plastering,finishing the wall upto wall surface complete. P-3a) Upto 50 mm conduit in brick wall

150

29

4350

... More
172 - Extra groove cutting in brick wall/CC floor to the suitable depth for concealing of conduit/GI pipe and plastering,finishing the wall upto wall surface complete. P-3b) Upto 50 mm conduit in CC floor

15

69

1035

... More
181 - Supplying and fixing of PVC casing & Capping on the wall or ceiling using necessary materials like bends,screws at an interval of 300 mm….etc., as required. P-3a)20 mm dia

150

28

4200

... More
182 - Supplying and fixing of PVC casing & Capping on the wall or ceiling using necessary materials like bends,screws at an interval of 300 mm….etc., as required. P-3b)25 mm dia

15

35

525

... More
191 - Supplying PVC/GI flexible conduit pipe….mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and the either end of the pipe terminated completely. P-3a)20 mm dia

45

19

855

... More
192 - Supplying PVC/GI flexible conduit pipe….mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and the either end of the pipe terminated completely. P-3b)25 mm dia

25

22

550

... More
193 - Supplying PVC/GI flexible conduit pipe….mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and the either end of the pipe terminated completely. P-3c)32 mm dia

10

29

290

... More
110 - Supplying and fixing of ""S"" hook made out of 14 mm dia M.S. Rod. P-3

66

52

3432

... More
111 - Supplying and fixing M.S. rafter clamp made out of M.S. flat & 14 mm M.S. rod. P- 3

66

160

10560

... More
112 - Supplying and fixing metal fan box with round hook. P-3

66

117

7722

... More
211 - Long point above 6 Mtr upto 10 Mtr from tapping point to out let via switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet."a) Short point upto 3 Mtr from tapping point to out let via switch.""a) Short point upto 3 Mtr from tapping point to out let via switch."

34

285

9690

... More
212 - Long point above 6 Mtr upto 10 Mtr from tapping point to out let via switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. b) Medium point above 3 Mtr upto 6 Mtr from tapping point to out let via switch b) Medium point above 3 Mtr upto 6 Mtr from tapping point to out let via switch

50

394

19700

... More
213 - Long point above 6 Mtr upto 10 Mtr from tapping point to out let via switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. c) Long point above 6 Mtr upto 10 Mtr from tapping point to out let via switch.

75

570

42750

... More
214 - Long point above 6 Mtr upto 10 Mtr from tapping point to out let via switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. "d)Two outlet in a row ,above 3 Mtrs. Upto 6 Mtrs. From tapping point to outlet via switches."

34

708

24072

... More
215 - Long point above 6 Mtr upto 10 Mtr from tapping point to out let via switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. e)Three outlet in a row,above 6 Mtrs. Up to 10 Mtrs. From tapping point to out let via switches.

35

1035

36225

... More
221 - Point wiring using copper wires without switch"Supplying & wiring adopting loop system in exesting PVC conduiting/Casing capping using copper PVC insulated multi strand 2x1.5 Sqmm copper wire with a 6 A flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet.Point wiring using copper a "a) Short point upto 3 Mtr from tapping point to out let via switch."

34

269

9146

... More
222 - Point wiring using copper wires without switch"Supplying & wiring adopting loop system in exesting PVC conduiting/Casing capping using copper PVC insulated multi strand 2x1.5 Sqmm copper wire with a 6 A flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet.Point wiring using copper a b) Medium point above 3 Mtr upto 6 Mtr from tapping point to out let via switch

50

379

18950

... More
223 - Point wiring using copper wires without switch"Supplying & wiring adopting loop system in exesting PVC conduiting/Casing capping using copper PVC insulated multi strand 2x1.5 Sqmm copper wire with a 6 A flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet.Point wiring using copper a c) Long point above 6 Mtr upto 10 Mtr from tapping point to out let via switch.

75

555

41625

... More
224 - Point wiring using copper wires without switch"Supplying & wiring adopting loop system in exesting PVC conduiting/Casing capping using copper PVC insulated multi strand 2x1.5 Sqmm copper wire with a 6 A flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet.Point wiring using copper a d) Two out let in a row, above 3 Mtr upto 6 Mtr from tapping point to out let via switches.

34

677

23018

... More
225 - Point wiring using copper wires without switch"Supplying & wiring adopting loop system in exesting PVC conduiting/Casing capping using copper PVC insulated multi strand 2x1.5 Sqmm copper wire with a 6 A flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet.Point wiring using copper a e) Three out let in a row, above 6 Mtrs upto 10 Mtrs from tapping point to out let via switches.

35

989

34615

... More
231 - Wiring for lighting/power circuit using one of FRLS pvc insulated 1100 Volts grade,Multistand copper conductor single core wire in open or concealed system of wiring as per IS -694:1990. P-6 1.0 Sqmm

1800

19

34200

... More
232 - Wiring for lighting/power circuit using one of FRLS pvc insulated 1100 Volts grade,Multistand copper conductor single core wire in open or concealed system of wiring as per IS -694:1990. P-6 1.5 Sqmm

2880

26

74880

... More
233 - Wiring for lighting/power circuit using one of FRLS pvc insulated 1100 Volts grade,Multistand copper conductor single core wire in open or concealed system of wiring as per IS -694:1990. P-6 2.5 Sqmm

2880

42

120960

... More
234 - Wiring for lighting/power circuit using one of FRLS pvc insulated 1100 Volts grade,Multistand copper conductor single core wire in open or concealed system of wiring as per IS -694:1990. P-6 4 Sqmm

540

63

34020

... More
331 - Supplying and surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates. The box should be Firmly/Surface/Flush mounted after due groove cutting in Brick/C.C wall, fixing including necessary rawl plugs,Machine/NF screws etc., complete. 1-2 way

17

103

1751

... More
332 - Supplying and surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates. The box should be Firmly/Surface/Flush mounted after due groove cutting in Brick/C.C wall, fixing including necessary rawl plugs,Machine/NF screws etc., complete. 3 way

5

124

620

... More
334 - Supplying and surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates. The box should be Firmly/Surface/Flush mounted after due groove cutting in Brick/C.C wall, fixing including necessary rawl plugs,Machine/NF screws etc., complete.Supplying and surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates. The box should be Firmly/Surface/Flush mounted after due groove cutting in Brick/C.C wall, fixing including necessary rawl plugs,Machine/NF screws etc., complete. 6 way

4

173

692

... More
335 - Supplying and surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates. The box should be Firmly/Surface/Flush mounted after due groove cutting in Brick/C.C wall, fixing including necessary rawl plugs,Machine/NF screws etc., complete. 8way

10

219

2190

... More
336 - Supplying and surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates. The box should be Firmly/Surface/Flush mounted after due groove cutting in Brick/C.C wall, fixing including necessary rawl plugs,Machine/NF screws etc., complete. 10 way

25

261

6525

... More
338 - Supplying and surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates. The box should be Firmly/Surface/Flush mounted after due groove cutting in Brick/C.C wall, fixing including necessary rawl plugs,Machine/NF screws etc., complete. 18 way

15

339

5085

... More
341 - Supplying & Flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after duo Groove cutting in brick/Stone.CC wall 1-2 way

17

138

2346

... More
342 - Supplying & Flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after duo Groove cutting in brick/Stone.CC wall 3 way

5

159

795

... More
351 - Supplying & Fixing of superior Quality modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwes.bolts nut etc., complete on the exixting metal/PVC box.a) 1 to 2 Module

17

137

2329

... More
353 - Supplying & Fixing of superior Quality modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwes.bolts nut etc., complete on the exixting metal/PVC box.b) 4 Module

5

175

875

... More
354 - Supplying & Fixing of superior Quality modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwes.bolts nut etc., complete on the exixting metal/PVC box. 8 module

4

284

1136

... More
355 - Supplying & Fixing of superior Quality modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwes.bolts nut etc., complete on the exixting metal/PVC box.e)10-12 Module

10

344

3440

... More
358 - Supplying & Fixing of superior Quality modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screwes.bolts nut etc., complete on the exixting metal/PVC box.f)16-18 Module

25

457

11425

... More
361 - Supplying & Fixing of modular switch/Socket /Stepped electronic fan regulator/dimmer/Telephone socket etc., on existing Modular switch plate as per IS 3854. a) 6 Amps one way.

300

102

30600

... More
362 - Supplying & Fixing of modular switch/Socket /Stepped electronic fan regulator/dimmer/Telephone socket etc., on existing Modular switch plate as per IS 3854. b) 6 A amps Two way switch.

4

166

664

... More
363 - Supplying & Fixing of modular switch/Socket /Stepped electronic fan regulator/dimmer/Telephone socket etc., on existing Modular switch plate as per IS 3854.c) 6 Amps 5 way Socket

55

171

9405

... More
364 - Supplying & Fixing of modular switch/Socket /Stepped electronic fan regulator/dimmer/Telephone socket etc., on existing Modular switch plate as per IS 3854.d) Stepped Fan Regulator.

60

357

21420

... More
368 - Supplying & Fixing of modular switch/Socket /Stepped electronic fan regulator/dimmer/Telephone socket etc., on existing Modular switch plate as per IS 3854.g)16 Amps one way switch.

20

180

3600

... More
3611 - Supplying & Fixing of modular switch/Socket /Stepped electronic fan regulator/dimmer/Telephone socket etc., on existing Modular switch plate as per IS 3854. j)6/16 Amps Universal socket.

20

236

4720

... More
370 - Supplying & Fixing 32 Amps security and energy saving DP switch with key tag suitable to operate on 230 Volts,50Hz AC supply & Competely wired on exixting box.

4

646

2584

... More
310 - Extra for supplying and fixing 4mm thick white plastic and covering for junction boxes of sizes….mm dia conduit using necessary machine screws. a)80 mm dia

300

15

4500

... More
3103 - Extra for supplying and fixing 4mm thick white plastic and covering for junction boxes of sizes….mm dia conduit using necessary machine screws. b)110 mm dia

50

21

1050

... More
311 - Supplying and fixing of 50 mm wooden plug,tapered from 50x50 mm to 25x25mm and fixing by using binding wire before concreting a roof slab.

200

12

2400

... More
3121 - Supplying……. Way plastic gang box and fixing using necessary wooden/rawl/phill plugs and screws. a) 1 way gang box

10

23

230

... More
3122 - Supplying……. Way plastic gang box and fixing using necessary wooden/rawl/phill plugs and screws. b) 2 to 4 way gang box

10

32

320

... More
3123 - Supplying……. Way plastic gang box and fixing using necessary wooden/rawl/phill plugs and screws. c) 6 to 10 way gang box

10

53

530

... More
3164 - Supplying & Fixing PBBC/Bakelite Straight or Slant batten holder wiring,with in 6Amp 230 V lamps.

300

71

21300

... More
1132 - Supplying of .feet -PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition." 1x4'-22 Watts

200

690

138000

... More
1163 - Supplying of recess mounting non integral type LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA LED modular down light 2'x2' /1'x4'42-55 W

2

4553

9106

... More
1182 - Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70% 2 Years against any manufacturing defect LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. 120 Watt

6

4024

24144

... More
5181 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve ,indicator ON/OFF, energy cross -3 with Short circuit breaking capacity of 10K and complete wiring as required. 6-32 Amps SP

25

415

10375

... More
5182 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve ,indicator ON/OFF, energy cross -3 with Short circuit breaking capacity of 10K and complete wiring as required. 40 Amps SP

5

793

3965

... More
5184 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve ,indicator ON/OFF, energy cross -3 with Short circuit breaking capacity of 10K and complete wiring as required. 6-32 Amps DP

4

739

2956

... More
5185 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve ,indicator ON/OFF, energy cross -3 with Short circuit breaking capacity of 10K and complete wiring as required. 40 Amps DP

2

1060

2120

... More
5187 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve ,indicator ON/OFF, energy cross -3 with Short circuit breaking capacity of 10K and complete wiring as required. 6-32 AmpsTPN

2

1717

3434

... More
5189 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve ,indicator ON/OFF, energy cross -3 with Short circuit breaking capacity of 10K and complete wiring as required. 40-63 Amps TPN

2

3044

6088

... More
51913 - Supplying and fixing regular MCB distribution boards on wall/ wood board/flush mounting using required clamps/bolts/nuts.,with provision for fixing suitable type capacity MCB's single phase /3 phase /single door with powder coated painting etc.Made out of 14 SWG MS enclosure.Double Door 12 way TP &N

6

8735

52410

... More
5124 - Supplying of on load change over switches 4 pole, AC-23A Duty, 415 V, 50 Hz, AC Supply a) 200 Amps"

1

15249

15249

... More
5146 - Supplying and fixing of 4 pole power contactor with NO/NC contacts on exsiting panel board using necessary bolts and complete wiring with AC-3 rating and as per IS-13947, (100-125 Amps)

1

16606

16606

... More
51510 - Supplying and fixing MCCB over the exsiting panel board using necessary scerws bolts, nuts and wiring complete. Protection of overload and short circuit with thermal magnectic/micro processor relaase and earth fault as per IS-13947 (Icu=Ics) Four Pole a) 125-160 Amps 25ka

1

10341

10341

... More
51212 - Supplying and fixing MCCB over the exsiting panel board using necessary scerws bolts, nuts and wiring complete. Protection of overload and short circuit with thermal magnectic/micro processor relaase and earth fault as per IS-13947 (Icu=Ics) Four Pole

1

17301

17301

... More
533 - Supplying of multi function digital meter with three line back light LCD type displayy for voltage, Current, Ferquency, power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completetly wired as required with communication port and class 0.5s accuracy

1

9315

9315

... More
053 - Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden CT. Class 0.5 accuracy with tape wound

3

526

1578

... More
054 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220V AC 50HZ 12/24V DC

3

515

1545

... More
5401 - Supplying . Amps rated 3 phase with neutral bus bar using required capacity electrolytic alluminum strips coverd with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40X6mm M.S flat frame work in existing panel board.the bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS Specification with necessary bolts, nuts and washers etc., complete.a)100Amps 4X30X6mm Aluminum strips

10

2465

24650

... More
5402 - Supplying . Amps rated 3 phase with neutral bus bar using required capacity electrolytic alluminum strips coverd with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40X6mm M.S flat frame work in existing panel board.the bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS Specification with necessary bolts, nuts and washers etc., complete. b)250 Amps 4X30X10mm Aluminum strips

8

3435

27480

... More
5421 - Fabricating Supplying and mounting MS box made out. SWG suitable for floor/ wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equppied with tamper proof loacking arrangment, with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. (16SWG)

75000

-

32250

... More
061 - Supplying,fixing, wiring, earth electrode for grounding conduits, I.C. cutouts & other equipments on the meter board using 40mm dia 2.90 thick G.I. pipe 2.5m long buried in a pit. The pit should be filled with equal proprotion of salt & charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc. is to be established through G.I.wire of size as per ISI specification 7.3.3 of IS 732 using 12mm dia bolts, nuts, washers & checknuts etc, the pipe shall have 16 through holes of 12mm dia. SR 2018-19

2

2999

5999.4

... More
063 - Supplying & running of G.I/Cu strips for grounding connections, using necessary fixing materials as required.SR 2018-19 I) G.I Strip a) 25 X 3 mm

10

75

750

... More
615 - Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1kv class(metal only)25 mm dia

4

84

336

... More
6152 - Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1kv class(metal only) 50mm dia

2

1785

3570

... More
617 - Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes.SR 2018-19 50 sqmm Long barrel

10

60

600

... More
061 - Supplying exhaust fan Of 1440 RPM of 300mm size with bracket blades suitable for operate on 230V 50Hz. AC supply complete.

4

1492

5968

... More
631 - Supplying Capacitor type Ceiling Fan complete with down rod blades, shackle, canopies etc., for operation on 230Volts,50 cycles. Single ohase AC Supply conforming to ISS-374-1979 and with double ball bearing system. Regular Model (48" Sweep)

60

2984

179040

... More
344 - Supplying & Flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after duo Groove cutting in brick/Stone.CC wall 6 way

4

220

880

... More
345 - Supplying & Flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after duo Groove cutting in brick/Stone.CC wall 8 way

10

261

2610

... More
346 - Supplying & Flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after duo Groove cutting in brick/Stone.CC wall 10 way

25

319

7975

... More
348 - Supplying & Flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after duo Groove cutting in brick/Stone.CC wall 18 way

15

405

6075

... More
615 - Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1kv class(metal only) 50mm dia

2

255

510



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.