Karnataka Slum Development Board Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Karnataka Slum Development Board - KSDB Tender

Works
Civil And Construction
Water Storage And Supply
Opening Date7 Nov 2024
Closing Date15 Nov 2024
Tender Amount₹ 1,21,99,553.17 
Notes
Download

Costs

Summary

Providing Ugd, Stp, Electrification And Water Supply For 477 Dus At Hiriyur Town At Chithradurga District

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
10.15.1 - Lowering, laying true to line and level of PVC Ringtite / PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS and commissioning (Contractor will make his own arrangements for procuring water for testing) etc. complete for: (Vol -5.P-121 Item no -10.15.1) 2023-24 P.W.D. S.R.25mm

99.6

21

2154.348

... More
16.9 - Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame(V-5 P.No. 191/ I.No.16.9 of PWD SR 2023-24)

10

5617

56176.2

... More
13.25.3 - Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments. Size 80 mm (PWD SR,2023-24, V-5Page 154 Item No 13.25.3)

2

1802

3605

... More
11.15.11 - Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.

10

2700

27006.6

... More
1.6 - Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work (Vol.1 Itemno-1.6 Page No-6 PWD SR 2023-24

711.1

498

354497.572

... More
16.18.5 - Construction of RCC Machinehole chambers of 1:1.5:3 proportion or approved type Cast-insitu / Pre-cast RCC Machinehole chambers, constructed using form vibrators of standard type, with barricading, danger lighting and using of sight rails and boning rods wherever necessary, shoring and strutting wherever required using Ordinary Port Land Cement, using 1:1.5:3 proportion RCC with 20 mm and down graded jelly, well graded sand and steel of approved quality, 200 mm thick top concrete slab, having wall thickness and raft thickness as in approved drawings and with an offset in raft alround the chamber as in approved drawing, benching concrete with 1:6 slope towards the central drain finished smooth, including fixing and grouting of pipes, including conveying to work spot supply and fixing SFRC Machinehole cover and frame (Heavy duty) conforming to IS:12592 with latest amendments, on a bed of CC 1:2:4 Providing and fixing of minimum 3 mm thick encapsulated plastic footsteps (as per IS 10910) on 12 mm dia. Grade Fe-500 steel bar (as per IS 1786) staggered at 300 mm apart as detailed in Technical specifications, including stone grit beding wherever required, watering, curing, engraving Machinehole number with flow direction on the inner cylindrical surface etc., complete including cost of reinforcement steel and fabrication charges and also cost and conveyance of all materials, labour with all lead and lifts. The Pre-cast RCC Machinehole are for various diamters and depths as stated below and as per detailed drawings, specifications and direction of the Engineer. For 1.2m dia Machinehole (PWD SR 2023-24, V-5 Page 194, Item No 16.18.5)

13

63161

821101.58

... More
16.18.3 - Constructing Pre-cast RCC Machinehole 1.2 m internal dia. , 1.6 M depth & SFRC cover & frame (PWD SR 2023-24, V-5 Page 194, Item No 16.18.3)

8

56345

450760.96

... More
10.2.5 - Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for: (PWD SR 2023-24, Volume-5 Page 114, Item No 10.2.5 )Pipes of SN4, 200mm dia

320

855

273897.6

... More
10.14.25 - Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges,handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.110mm (PWD SR 2023-24, Volume-5 Page 121, Item No 10.14.25 )

773

520

402075.95

... More
10.14.26 - Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, layingtrue to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.140mm (PWD SR 2023-24, Volume-5 Page 121, Item No 10.14.26 )

304

783

238284.32

... More
1.10 - Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications. (Vol -1.P-7 Item no -1.10) 2023-24 P.W.D. S.R.

593.89

164

97873.072

... More
16.9 - Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame(V-5 P.No. 191/ I.No.16.9 of PWD SR 2023-24)

76

5617

426939.12

... More
16.10 - Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(V-5 P.No. 191/ I.No.16.10 of PWD SR 2023-24)

76

4363

331594.08

... More
8.57 - Supplying & fixing Composite Fibre Reinforced Polymer (FRP) utility cover conforming to IS 12592:2002 with sufficient load bearing capacity as per technical specifications. (V-3 P.No. 79/ I.No.8.57 of PWD SR 2023-24) Light Duty Square 450x450 mm with load bearing capacity upto 5t

76

2884

219184

... More
8.57 - Light Duty Square 600x600 mm with load bearing capacity upto 5t

76

3090

234840

... More
1.4 - Wall bores in Brick masonry upto 45 cm thick.

76

86

6575.52

... More
12.1.1 - Sinking of Borewell of 165 mm dia clear, using super fast hydraullc rig of capacity 300 PSIG & above 1100 CMF & above in all strata inluding over burdern upto 20m fixing of casing pipes collars and capp with ecessary cutting threading and welding including transportation of rig and supporting vechicle crew charges and cost of consumables etc., complete inluding yiled testing at the final depth with a minimum working of compressor for one hour (Excluding cost of cassing pipes collars cap etc., complete) VOL-5 Pg-139 Item no-12.1 PWD SR2023-2024 a) 0.00 to50.00 Mtr VOL-5 Pg-139 Item no-12.1.1

50

381

19055

... More
12.1.2 - b) 50.00 to 100.00 Mtr VOL-5 Pg-139 Item no-12.1.2

50

477

23896

... More
12.1.3 - c) 100.00 to 150.00 Mtr VOL-5 Pg-139 Item no-12.1.3

50

507

25389.5

... More
12.32 - Supply of ISI Mark 175mm nominal Bore, Plain end steel casing Pipe-grade of steel Fee 4100 of wakk thickness 504mm thick confirming to IS 4270:2001 and latest amendments, electric resistance welded steel electric or basic oxygen process in fandom length of 5 to 7mtr. Both ends threaded confirming to Is554/1985 one end fixed with socket confirming to IS 270:2001 and other end with screwed pipes. All pipes shall be reasonably free from defectes. The tubes shall be resonably straigth should be with ISI Marking Weighting 25.10 kg/mtr (Inclusive of all taxes and durties) Prices include Collar - medium duty. VOL-5 Page No.143, I.No.12.32 PWD SR 2023-24

18

1990

35837.82

... More
12.33 - Supply of 175 mm M.S. Collar VOL-5 Page No.143, I.No.12.33 PWD SR 2023-24

1

154

154.5

... More
12.34 - Supply of 175 mm M.S. Cap VOL-5 Page No.143, I.No.12.34 PWD SR 2023-24

1

168

168.92

... More
13.16.6 - Providing,supplying to work site,fixing of Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. (VOL-5 Pg-152, It No. 13.16.6) PWD SR 2023-24

1

49061

49061.99

... More
13.22.3 - Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. (VOL-5 Pg-154, It No. 13.22.3) PWD SR 2023-24

160

139

22248

... More
13.27.1 - Supply and delivery of galvanized mild steel tubes heavy class (C Class) as per IS 1239 (Part-I) 1990 with latest amendments with ISI Mark (one end fitted with Heavy Duty collar and other end fitted with protective cover) (VOL-5 Pg-155, It No. 13.27.1) PWD SR 2023-24

75

3141

235612.5

... More
13.23.3 - Supply, installing,testing and commissioning COMMON control panel consisting of the following Phase Indication Lamp-3 Nos,Fault Indication Lamp-1 No, Digital VAF meter -1 No ,On/Off illuminated push button-2 Nos including protection for a)over voltage, b)under voltage,c)voltage unbalance,d)over current,e)Dry run,f)Provision to connect float switch, Indoor type. NOTE: 1)DOL- Direct Online Starter 2)S-D- Star Delta Starter (VOL-5 Pg-155, It No. 13.23.3) PWD SR 2023-24

1

16377

16377

... More
13.33 - Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work.(VOL-5 Pg-156, It No. 13.33) PWD SR 2023-24

1

1390

1390.5

... More
13.32 - Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work.(VOL-5 Pg-156, It No. 13.32) PWD SR 2023-24

1

6695

6695

... More
1.6.1 - Earth work excavation for pipelines/cables by Manual means upto 600mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. (Vol -1.P-6 Item no -1.6.1) 2023-24 P.W.D. S.R.

243

498

121140.36

... More
10.14 - Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.(VOL-5 Pg-120, It No. 10.14) PWD SR 2023-24

600

197

118656

... More
1.1 - Refilling the basement and pipeline trenches with selected available earth from trench excavation including watering, Consolidation in layers of 15 cm thick including disposing of the surplus earth with all lead & lifts. (Compacting with vibro roller) Note: Add Rs. 203.00 / cum for earth obtained from borrow pits.(VOL-1 Pg-7, It No. 1.1) PWD SR 2023-24

243

164

40046.4

... More
2.1.2 - Supplying 19mm dia 2mm thick Pipe, Juke Box bend wiring using 3/36" copper wire, Switch gang box etc., for point wiring (P-5, It No. 2.1.2)

2

252

504.7

... More
7.12.2 - Supplying and fixing of Class A (Medium duty) GI Pipe wall thickness not less than 3.25mm on pole/wall/drain crossing 50mm (P.No. 62, It No.7.12.2)

1.8

402

724.914

... More
12.56 - Supplying, fixing, wiring, earth electrode for grounding conduits, I.C.cutouts and other equipment's on the meter board using 40 mm dia2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia (P-54, It No. 12.56) V-6 ELE SR 2023-24

1

3615

3615.3

... More
12.56 - Supplying and fixing PBBC/bakelite straight or slant batten holder and wiring within 60w/230volts lamps

2

90

181.28

... More
5.7.2 - Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers 32 Amps (V-6 P-14, It No. 5.7.2) ELE SR 2023-24

6

185

1112.4

... More
5.6.4 - Supplying and fixing polished wood board made of not less tha 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws 12" x 12" x 2" (P-14, ItNo.5.6.4)V-6 ELE SR 2023-24

2

157

315.18

... More
13.3 - Main connection from poll PVC insulated sheathed stee / wire cable 1/2 x 10 Sqmm P-57, It No. 13,3

38

176

6694.08

... More
14.03 - Wiring for lighting/power circuit using on of FRLS PVC insulated 1100 V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified 4 Sqmm (P-6 It No.14.03)-6 ELE SR 2023-24

15

50

757.05

... More
1.4.1 - BESCOM DEPOSTIE

1

50000

50000

... More
10.6 - RCC hume pipe Circular pump house: Providing precast RCC Circular Hume pipe pump house with M.S door and RCC conical roof as per specification and drawings - Internal dia Mtr. 1200 mm & height of 2.5 Mtr. With Wall thickness 65mm etc. complete (VOL-5 Pg-116, It No. 10.6) PWD SR 2023-24

1

16893

16893.03

... More
11.1 - Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete.(VOL-5 Pg-127, It No. 11.1) PWD SR 2023-24 b)20mm

4.8

231

1112.4

... More
11.1 - e)40mm

8

424

3394.88

... More
11.8 - Supply and delivery at site wrought middle steel (galvanized) GI bend confirming to IS 1239-II, 1991 with latest amendments if any (VOL-5 Pg-130, It No. 11.8) PWD SR 2023-24

2

275

550.02

... More
15.72.1 - GI collar: Providing wrought mild steel (galvanized) GI collar confirming to IS 1239-II, 1991 with latest amendments if any. (Page No- , Item No-15.72, RWS SR -2019-20 Bglr Circle) Item No-15.72.1 b)20mm

8

66

535.6

... More
15.72 - Item No-15.72.4 e)40mm

4

139

556.2

... More
1.4.1 - Steel Bib cock 20mm dia

8

149

1194.8

... More
11.17.5 - Providing GM (copper alloy) wheel valves/ check valve confirming to IS 778/1990 Class-I with latest amendments No. 1 and with ISI mark screwed in bonnet integral seat inside, screw, rising spindle screwed female ends confirming to IS 554/ 1990 body hudraulically tested 1.50 HP seat hydraulically tested 1.00 HP etc. complete For 40 mm dia GM (Copper alloy) wheel valves / check valve (VOL-5 Pg-134, It No. 11.17.5) PWD SR 2023-24

2

1172

2344.28

... More
1.17 - Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata.(VOL-1 Pg-10, It No. 1.17) PWD SR 2023-24

4.42

269

1192.7812

... More
2.2.1 - Providing and laying in position reinforced cement concrete of Design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregtes @ 0.460 cum, with super plasticisers @ 3 liters machine mixed, concrete laid in layers, vibrated for all works in foundation for footings, pedastals, retaining walls, return walls, walls including attached pilasters, columnspillars, posts, struts, buttresses, bed blocks, anchor blocks & plinths etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement complete as per specifications, with all lead and lift and as per direction of the Engineer in charge. Footing Concrete (Vol -1.P-15 Item no -2.2.1) 2023-24 P.W.D. S.R.

2.01

6475

13015.9761

... More
1.4.1 - Providing and constructing granite / trap / basalt size stone masonry in basement with cement mortar 1:6, edges of stones chistle dressed in courses not less than 15 cms high, bond stones at 2 m. apart in each course including cost of materials, labour, curing complete as per specifications.

4.5

5833

26252.64

... More
2.2.1 - Providing and laying in position reinforced cement concrete of Design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregtes @ 0.460 cum, with super plasticisers @ 3 liters machine mixed, concrete laid in layers, vibrated for all works in foundation for footings, pedastals, retaining walls, return walls, walls including attached pilasters, columnspillars, posts, struts, buttresses, bed blocks, anchor blocks & plinths etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement complete as per specifications, with all lead and lift and as per direction of the Engineer in charge. Footing Concrete (Vol -1.P-15 Item no -2.2.1) 2023-24 P.W.D. S.R.

1.92

6475

12433.1712

... More
21.1 - Providing ruled pointing to coursed stone masonry with lime mortar 1:3,20mm deep, after raking joints to depth of 20mm nicely lining, including cost all materials, labour, usage charges of machinery, curing complete as per specification (Vol -2.P-214 Item no -21.1) 2023-24 P.W.D. S.R.

4.8

307

1478.256

... More
10.7 - Erection and positioning of RCC Hume pipe pump house/Cistern on size stone masory platform including transportation charges and handling,finishing with all necessary tools ,plants and materials etc.,complete as directed by the Engineer in charge of the work.(VOL-5 Pg-116, It No. 10.7) PWD SR 2023-24

2

1938

3876.92

... More
1.4.1 - Labour charges for making end connectinfron raising main to cistern using 50mm dia GI pipes and delivery conections using 20mm to 25mm dia GI pipes with necessary specials wherever necessary including cutting, threading, placing and fixing in position with all lead and lift etc., complete

2

1456

2912.84

... More
8.25 - Providing and applying two coats with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge (Vol -2.P-45 Item no -8.25) 2023-24 P.W.D. S.R.

18.85

141

2659.9235

... More
4.2.8 - Fabricating, supplying and erection of . ms long hot dip Galvanized Octagonal hot dip Pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per ISspecifications suitable to withstand the wind speed of 47 m/s for .m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom . mm , top. mm with 3 mm thick, suitable base plate and 4Nos of . long J bolts along with template and the Pole shall be hot dip galvanized in singledipping with not less than 65micron as per ASTM-A123 and 153 etc., (excluding foundation) as per drawing appended.10 m - Top 70 mm and Bottom 175 mm dia(PWD ELE SR Pg-11, It No. 4.2.8) 2023-24

1

22145

22145

... More
4.6 - Supplying, and fixing of Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete.Double Arm Bracket with 2000 mm Standard 40/50 mm dia (PWD ELE SR Pg-13, It No. 4.6) 2023-24

2

3914

7828

... More
1.4.1 - Earth work excavation by manual means for drains,canals, waste weir,draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading,caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.In all kinds of soils Depth upto 1.5 m (Vol -1.P-5 Item no -1.4.1) 2023-24 High mast dimension 1x1.85x1.85x1.7=5.82

2.16

249

538.4016

... More
2.1.2 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, ell compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. (Vol -1.P-15 Item no -2.1.2) 2023-24 High mast dimension 1x1.85x1.85x1.7=5.82

0.14

5833

816.7488

... More
2.11 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Vol -1.P-18 Item no -2.11) 2023-24 High mast dimension 1x1.85x1.85x1.7=5.82

0.067

94320

6319.45273

... More
1.4.1 - Centering Shuttering For Columns & Peirs

2.97

660

1960.8831

... More
2.2.1 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Vol -1.P-15 Item no -2.2.1) 2023-24 High mast dimension 1x1.85x1.85x1.7=5.82

0.93

6475

6022.3173

... More
11.9.7 - Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr Lumen Maintenance of 70, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with . W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.LED Floodlight 240W(PWD ELE SR Pg-46, It No. 11.9.7) 2023-24

1

22730

22730.04

... More
2.3.5 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010(PWD ELE SR Pg-5, It No. 2.3.5) 2023-24

50

94

4738

... More
3.9 - Supplying and fixing hylum plastic sheet 3mm thick with necessarynitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N. F. screws(PWD ELE SR Pg-9, It No. 3.9) 2023-24

2833

-

1019.88

... More
5.7.3 - Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers 63Amphs(PWD ELE SR Pg-14, It No.5.7.3) 2023-24

4

413

1652.12

... More
5.14 - Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947 65A(PWD ELE SR Pg-16, It No.5.14) 2023-24

1

10445

10445.23

... More
5.18.9 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 63Amps TPN(PWD ELE SR Pg-17, It No.5.18.9) 2023-24

1

3180

3180.64

... More
5.48 - Supplying and fixing Microprocessor Based Astronomical timer Switch with using necessary bolts, nuts and washers.(PWD ELE SR Pg-21, It No.5.48) 2023-24

1

4988

4988.29

... More
5.42.2 - Fabricating supplying and mounting MS box made out .SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete 16 SWG(PWD ELE SR Pg-20, It No.5.42.2) 2023-24

16250

-

7150

... More
5.41.3 - Supplying and fixing angle iron frame work fabricated out of M.S.angle iron. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75 x 75 x 6 mm(PWD ELE SR Pg-20, It No.5.41.3) 2023-24

16

571

9146.4

... More
51.02 - Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg(PWD ELE SR Pg-22, It No.51.02) 2023-24

4

696

2785.12

... More
51.03 - Good Quality Salt for grounding purposes packed in 50 Kg gunny ba(PWD ELE SR Pg-22, It No.51.03) 2023-24

4

319

1277.2

... More
1.6.2 - Digging of Pit for providing GI Pipe type Earthing Hard Soil(PWD ELE SR Pg-43, It No.1.6.2) 2023-24

4

3079

12318.8

... More
32.08 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 25 Sqmm, 4 Core, (13 GI Strips - 4 x 0.8 mm(PWD ELE SR Pg-13, It No.32.08) 2023-24

0.0965

185280

17879.57018

... More
29.03 - Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed.(PWD ELE SR Pg-63, It No.29.03) 2023-24

18.27

400

7320.2409

... More
21.05 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff.(PWD ELE SR Pg-52, It No.21.05) 2023-24

0.0925

21512

1989.91365

... More
66.04 - HDPE/PLB Pipe 50/42 mm(PWD ELE SR Pg-30, It No66.04) 2023-24

0.0835

87564

7311.62907

... More
48.05 - GI Pipe B - Class as per IS-1239 GI Pipe - 50 mm Dia(PWD ELE SR Pg-38, It No 48.05) 2023-24

9

333

3003.48

... More
51.01 - GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg(PWD ELE SR Pg-22, It No.51.01) 2023-24

4

765

3061.16

... More
1.3.1 - Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20 mm dia 2 mm thick (Common SR PWD ELE VOL-6 SR 2023-24 -Part-3 Chapter-1 Item No. - 1.3.1 Page No.2)

292

70

20451.68

... More
32.07 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 25 Sqmm, 3.5 Core, (12 GI Strips - 4 x 0.8 mm) (Common SR ELE VOL-6 SR 2023-24 - Item No. - 32.07, Page No.13)

0.876

143735

125912.27172

... More
21.05 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 to 25 Sqmm(Common SR ELE VOL-6 SR 2023-24 - Item No. -21.05, Page No.52)

0.876

21512

18845.02008

... More
1.6.1 - Earth work excavation for pipelines/cables by Manual means upto 600mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. (Vol -1.P-6 Item no -1.6.1) 2023-24 P.W.D. S.R.

394.2

498

196516.584

... More
28.08 - Laying the GI Pipe 80 mm to 150 mm dia at Drainage Water Supply Crossing including fixing collars elbows, bends, Tees and other fitting with Cuts and Threads wherever necessary complete.(Common SR ELE VOL-6 SR 2023-24 - Item No. -28.08, Page No.56)

372.3

95

35662.617

... More
35.02 - Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cabl 3.5 x 70/95/120 Sqmm(Common SR ELE VOL-6 SR 2023-24 - Item No. -35.02, Page No.15)

73

393

28722.58

... More
5.44.1 - Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof,dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.300mmx300mmx214mm (Common SR ELE VOL-6 SR 2023-24 - Item No. -5.44.1, Page No.21)

73

4647

339257.28

... More
5.30 - Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 20A single phase Class-1 Accuracy with Temper Proof Energy Meter.(Common SR ELE VOL-6 SR 2023-24 - Item No. -5.30, Page No.19)

73

1421

103762.2

... More
5.15.1 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection forShort-Cicrcuit/Over Load. For Microprocessor MCCBS Facility forsegregating Priority and Non-Priority loads must be available in theMCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. THREE POLE 5.15.1 100Amps 25kA.(Common SR 2021-22 Electric PWD Part-1 - Item No. - 5.14.1, Page No.12) (Common SR ELE VOL-6 SR 2023-24 - Item No. -5.15.1, Page No.17)

73

6268

457606.34

... More
1.5.2 - Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m

48

458

22000.8

... More
2.2.1 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)

4.06

6475

26290.9766

... More
111 - APPENDIX I Additionalities for Formwork, Centering & Scaffolding 8% is taken from page no 111

4.06

518

2103.283

... More
2.3.3 - Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)

14.4

6246

89956.08

... More
1.4.1 - APPENDIX I Additionalities for Formwork, Centering & Scaffolding 8% is taken from page no 111

14.4

499

7196.4

... More
2.12 - Supplying, fitting and placing Mild steel reinforcement complete in sub structure as per drawing and technical specification

1.44

75924

109331.1216

... More
7.8 - Supplying and fixing 40mm dia. GI pipe medium duty pipes hand railing 3 rows fixed to RCC 1:2:4 vibrated post of 150x150mm at bottom and 100x150mm at top, placed at 2 Mtrs. intervals for a height of 750mm including curing, painting GI pipes with two coats of anticorrosive steel paint over a primer coat etc. with all lead lift etc. (The rate per meter is for 3 rows of GI pipes and RCC post) Water supply & UGD Works Common CSR

2

1366

2733.62

... More
1.9 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m Note : 1) Add 5% per m3 for every additional 1.50m depth or part thereoff beyond 4.50 m depth is provided 2) Add 3% per m3 for every additional 1.50m depth or part thereoff beyond initial 1.50 m depth if shoring and strutting is provided

48

273

13151.04

... More
1.4.1 - Providing, designing, engineering, procurement, installation and commissioning of sewage treatment plant of 50 KLD capacity with moving bed bio reactor (MBBR) technology, including all electromechanical works to achieve BOD-10ppm, TSS-10ppm & COD-30ppm to get recyclable quality of water for industrial / agricultural purposes. The following works are mandatory in this item code which may differ as per contractor's design.

1

2821000

2821000

... More
11.62 - Providing and fixing RCC precast fencing pole of size 0.15mx0.15mx2.0m casted in M 20 with 20mm down size aggregates making holes for drawing barbed wire at 30 cm c/c using 8 mm dia vertical 4 TMT steel rods and 6 mm dia stirups at 15 cm c/c fixed 1.5 m above Ground level using steel moulding , curing , transportationto work spot including excavation in all types of soil, fixing in plain cement concrete M15 using 20 mm downsize aggregate includingaligning to plumb and line providing including cost of all materials, labour,usage charges of machinery complete.

20

1117

22351

... More
11.60 - Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.

200

919

183958

... More
1.1 - 9M Length PSCC Pole 300 KG PARTICULARS AMOUNT

1

5204

5204

... More
1.1 - 9M Length PSCC Pole 300 KG ESTIMATTION COST

1

1794

1794

... More
1.2 - 11 KV Horizontal HTST Support Clamp & Bolt Nut & Washer (PSCC Pole) PARTICULARS AMOUNT

2

1324

2649.16

... More
1.2 - 11 KV Horizontal HTST Support Clamp & Bolt Nut & Washer (PSCC Pole) ESTIMATION COST

2

280

560

... More
1.3 - Rabit 1.5% with Sag PARTICULARS AMOUNT

0.183

60293

11033.619

... More
1.3 - Rabit 1.5% with Sag ESTIMATION COST

0.183

4492

822.036

... More
12.1 - Sprial Earth Electrode PARTICULARS AMOUNT

1

246

246

... More
12.1 - Sprial Earth Electrode ESTIMATION COST

1

96

96

... More
13.1 - GI Wire Lasing EG Strips Particulars Amount

1

296

296

... More
13.1 - GI Wire Lasing EG Strips Estimation Cost

1

102

102

... More
15.1 - Accident Name Board

2

155

310

... More
15.1 - Accident Name Board

2

82

164

... More
16.1 - 12M/01

2

92

184

... More
16.1 - 12M/01

2

43

86

... More
18.1 - Other Equipments

1

56

56

... More
18.1 - Other Equipments

1

43

43

... More
1.1 - 9M Length PSCC / PSCC Joint Pole Measurment 100/250 KVA

2

28519

57038

... More
1.1 - 9M Length PSCC / PSCC Joint Pole Measurment 100/250 KVA

2

7192

14384

... More
4.1 - Set

4

1205

4820

... More
4.1 - Set

4

611

2444

... More
5.1 - 11KV/433 V, 50 Cycle 100 KVA (BEE 4 Star Rated)

1

217958

217958

... More
5.1 - 11KV/433 V, 50 Cycle 100 KVA (BEE 4 Star Rated)

1

1638

1638

... More
6.1 - Earthing Materials

8

1781

14248

... More
6.1 - Earthing Materials

8

977

7816

... More
6.1 - Accident Name Board

2

155

310

... More
6.1 - Accident Name Board

2

82

164

... More
8.1 - 12M /01 KG)

4

92

368

... More
8.1 - 12M /01 KG)

4

43

172

... More
9.1 - Gy Set Concreter (without Cement)

4

258

1032

... More
1.1 - 9KV 5 KV METAL OXIDE

2

4895

9790

... More
1.1 - 9KV 5 KV METAL OXIDE

2

123

246

... More
13.1 - LT Protection Kit

4

2084

8336

... More
13.1 - LT Protection Kit

4

367

1468

... More
1.1 - Aluminium Wire 240 CMM

180

268

48240

... More
1.1 - Silver Lugs 240 CMM

48

366

17568

... More
1.1 - Rabit to PVC Wire PG Clamp 240 CMM

16

422

6752

... More
1.1 - Spessors

32

43

1376

... More
1.1 - Fish Plae, Clamp, Bolt Nut & Washer (GI)

8

272

2176

... More
1.1 - Fish Plae, Clamp, Bolt Nut & Washer (GI)

8

489

3912

... More
1.1 - LT Distribution Box MCCB Switch

2

23498

46996

... More
1.1 - LT Distribution Box MCCB Switch

2

396

792

... More
1.1 - LT Metering Box with CT

2

5555

11110

... More
1.1 - LT Metering Box with CT

2

891

1782

... More
1.1 - 5A. 0.5 ETV above 18 KW

2

3498

6996

... More
1.1 - 5A. 0.5 ETV above 18 KW

2

494

988

... More
1.1 - 11 KV GOS 200 A single Brake

2

9734

19468

... More
1.1 - 11 KV GOS 200 A single Brake

2

1137

2274

... More
1.1 - 11 KV HG Fuse Unit

2

1101

2202

... More
1.1 - 11 KV HG Fuse Unit

2

244

488

... More
1.1 - PARI

2

20600

41200

... More
20.1 - Alkathin Tube round 19 CMM

2

533

1066

... More
21.1 - Other Equipments

1

58

58

... More
1.1 - Other Equipments

1

65

65

... More
1.1 - 9M Length PSCC Pole 300 Kg

6

5204

31224

... More
2.1 - 9M Length PSCC Pole 200 Kg

24

4325

103800

... More
3.1 - 9M Length PSCC Pole 200 Kg Stud

7

4325

30275

... More
4.1 - Fish Plae, Clamp, Bolt Nut & Washer (GI)

7

165

1155

... More
6.1 - 1.1 KV Class 3 Phase Arial Bunched Cable (3*95+1*16+1*70 CMM)

1.16

508914

590340.24

... More
6.1 - 1.1 KV Class 3 Phase Arial Bunched Cable (3*95+1*16+1*70 CMM)

1.16

34102

39558.32

... More
7.1 - Universal Hook

74

343

25382

... More
7.1 - Universal Hook

74

198

14652

... More
8.1 - Suspension Clamp Assembly with Pole Clamp

74

366

27084

... More
8.1 - Suspension Clamp Assembly with Pole Clamp

74

198

14652

... More
9.1 - Dead End / anchor Clamp Assembly

74

157

11618

... More
8.1 - Dead End / anchor Clamp Assembly

74

200

14800

... More
10.1 - High hook Clamp Fitting

74

105

7770

... More
11.1 - End Camps

12

24

288

... More
12.1 - Three Phase Distribution Box

30

2473

74190

... More
12.1 - Three Phase Distribution Box

30

929

27870

... More
13.1 - Free Sizing Connector

150

273

40950

... More
13.1 - Free Sizing Connector

150

165

24750

... More
14.1 - Sprial Earth Electrode

30

246

7380

... More
14.1 - Sprial Earth Electrode

30

96

2880

... More
15.1 - Ploro Set Light Fitting & Tube

30

434

13020

... More
15.1 - Ploro Set Light Fitting & Tube

30

277

8310

... More
16.1 - MSC Meter Housing Box, Phase-1 Phase-6 30 A class 1 & Self Street Light Control Switch (inlcude)

2

6164

12328

... More
16.1 - MSC Meter Housing Box, Phase-1 Phase-6 30 A class 1 & Self Street Light Control Switch (inlcude)

2

983

1966

... More
17.1 - 40 MM PVC Pole

50

116

5800

... More
16.1 - 40 MM PVC Pole

50

220

11000

... More
18.1 - 25 CM 1 Core PVC wire

50

36

1800

... More
19.10 - Accident Name Board

30

155

4650

... More
19.10 - Accident Name Board

30

82

2460

... More
21.10 - Road Gaurding HT / LT Route Center

1

1858

1858

... More
1.1 - Electric

1

10000

10000

... More
1.1 - 11000/440 volts, 50 Cycle, 3Phase, 100 KVA (5 Star Rated)

1

217958

217958

... More
1.1 - 11000/440 volts, 50 Cycle, 3Phase, 100 KVA (5 Star Rated)

1

1638

1638



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.