Karnataka Slum Development Board Tender
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
Karnataka Slum Development Board - KSDB Tender
Civil And Construction
Building Construction
Opening Date24 Sep 2024
Closing Date7 Oct 2024
Tender Amount₹ 84,69,054.9
Costs
EMD
₹ 1,69,500Document Cost
Refer DocumentsTender Fee
₹ 2,120
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
KSDB/2024-25/OW/WORK_INDENT178Tender No
KSDB/2024-25/OW/WORK_INDENT178Tender Authority
Karnataka Slum Development Board ViewPurchaser Address
-Website
http://eproc.karnataka.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
code04 - Dismantling weather proof course and removing and conveying the debris to a distance to the appropriate disposal area as per direction of Engineer-in-charge .complete as per the specifications and directions of engineer in charge of work.complete as per the specifications and directions of engineer in charge of work.complete as per the specifications and directions of engineer in charge of work
46.8
658
30838.392
... More
code05 - Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 5.0 conforming to IS: 2222 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Non modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
54.95
12557
690044.516
... More
code06 - Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc. to be paid separately) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
17.97
5401
97073.2212
... More
code07 - Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
10.5
9467
99411.27
... More
code08 - Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.complete as per specifications and as per directions of the Engineer-in-Charge.
0.372
157956
58759.8738
... More
code09 - Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications and as per directions of the Engineer-in-Charge.
4.2
8515
35766.906
... More
code10 - Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made.complete as per specifications and as per directions of the Engineer-in-Charge.
57.6
7703
443732.544
... More
code11 - Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).complete as per specifications and as per directions of the Engineer-in-Charge.
288.25
2276
656218.42
... More
code12 - Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge Size of Tile 600x1200 mm.complete as per specifications and as per directions of the Engineer-in-Charge.
288.25
120
34624.59
... More
code13 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specificationscomplete as per specifications and as per directions of the Engineer-in-Charge.
49.06
6479
317889.6666
... More
code14 - Providing & Fixing of Mineral Fibre Acoustical Suspended Ceiling System in module size of 600 x 600 x 20mm with Exposed Grid for Hospitals, Shopping malls, Commercial establishments and office complexes. The tiles should have Humidity Resistance (RH) of 99%, NRC 0.7, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 I Class 1 (BS 476 pt- 6 & 7)with sand texture finish andsuitable for Green Building application with Recycled content of 47%. The tile shall be laid on 24 mm wide T- section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm and a load carrying capacity of 15 kg/m2 &pull out strength of minimum 100 kg The T Sections should have a Galvanizing of 90 g/m2 and need to be installed with Suspension system..complete as per specifications and as per directions of the Engineer-in-Charge.
273.4
3077
841350.224
... More
code15 - Providing and supplying 'Acoustical Wall Paneling' with square edges made of fibre glass substrate 25mm thick and wrapped on the front side with an acoustically transparent and classified for Fire reaction Class A, as per ASTM E-84, fabric with option of colors - as per the choice of the Architect/Engineer incharge of the size 600x600mm, 600x1200mm & 600x1800mm providing a minimum sound absorptionlevel of 0.85 NRC to be affixed to wall using Wall panel lmpaler sand construction adhesives as per the instructions laid down by the certified manufacturer.complete as per specifications and as per directions of the Engineer-in-Charge.
475.68
6551
3116503.1424
... More
code16 - Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. .complete as per specifications and as per directions of the Engineer-in-Charge.
6
132
792
... More
code17 - Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. .complete as per specifications and as per directions of the Engineer-in-Charge.
10
1225
12254
... More
code18 - Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. .complete as per specifications and as per directions of the Engineer-in-Charge.
8
1157
9257.6
... More
code19 - Providing & fixing Roller Blinds of reputed make 38mm round Aluminium channel with blackout fabric, telting with chain (Ball) system with all necessary fittings and fixtures as per direction of Engineer in charge.complete as per specifications and as per directions of the Engineer-in-Charge.
57.6
1980
114048
... More
code20 - Providing and laying linoleum plain flooring or coloured 3.2mm thick sheet / tiles laid with an approved adhesive on sub floor stretching, cutting and fixing complete , including cost of materials, labour, complete as per specifications.
177
994
176008.8
... More
code21 - Finishing with Epoxy paint (two coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Enginer-in-charge.
730.469
241
176488.61509
... More
code22 - Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required complete as per specifications and as per directions of the Engineer-in-Charge.
1
6574
6574.7
... More
code23 - Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixercomplete as per specifications and as per directions of the Engineer-in-Charge.
1
4533
4533.1
... More
code24 - Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
1
299
299.2
... More
code25 - Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan..complete as per specifications and as per directions of the Engineer-in-Charge.
1
126
126.5
... More
code26 - Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete..complete as per specifications and as per directions of the Engineer-in-Charge.
2
1342
2684
... More
code27 - Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 g.complete as per specifications and as per directions of the Engineer-in-Charge.
1
349
349.8
... More
code28 - Providing and fixing Bib cock Two way with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete- Class Economy.complete as per specifications and as per directions of the Engineer-in-Charge.
1
2120
2120.8
... More
code29 - Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.complete as per specifications and as per directions of the Engineer-in-Charge.
1.5
9403
14105.52
... More
code30 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 110mm dia., 6 kg/sqcm & class 3.complete as per specifications and as per directions of the Engineer-in-Charge.
20
452
9042
... More
code31 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For:PVC pipes 50mm dia., 6 kg/sqcm & class 5.complete as per specifications and as per directions of the Engineer-in-Charge.
60
111
6666
... More
code32 - Providing and grouting tile joints, Cutting the tile joints with the help of cutting machine (width 3mm-15mm) and filling with of matching shade, using three component Epoxy based tile joint filler, non-sag waterproof grout, chemical and UV resistance, Pot life less than or equal to 60 mins, VOC (EPA 24) less than 8gm/kg and water absorption after 7 days less than 0.5g Joints shall be clean, dry, free from dirt, etc prior to application. Apply tile grout using a rubber trowel/grout floater, press firmly into joints, ensure complete fill and remove excess grout from surface using suitable method. The work shall be carried out as per the directions of the Engineer in charge.
5
972
4862
... More
code33 - Providing & fixing upvc ventilator with Exhaust Turbo speed fan with 5 blades (300mm x 300 mm & above sized fan) with copper motor having mounting arrangements as per direction of Engineer in charge of work
1
2145
2145
... More
code34 - Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge.
1000
334
334400
... More
code35 - Supplying of recess mounting non integrated type LED down light...... W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 100 lumen per W, 120degree beam spread, lifegreater than 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater than 0.95, power loss should lessthan 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 24 Wcomplete as per specifications and as per directions of the Engineer-in-Charge.
26
1733
45058
... More
code36 - Supplying & fixing - flexible LED Strip Light ..... W Power consumption in 5 ms length CCT6500 degree K, CRI greater than 70%. efficacy greater than80 lumen per W, life greaterthan 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver non integrated, with PFgreater than 0.95, power loss should lessthan 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved with 2 years Warranty against any manufacturing defect working under standard electrical condition. .complete as per specifications and as per directions of the Engineer-in-Charge.
100
1291
129100
... More
code37 - Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 56" Sweep (1400 mm) Regular model..complete as per specifications and as per directions of the Engineer-in-Charge.
5
3031
15155
... More
code38 - Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screw satan interval of 300 mm as required. 25mm .complete as per specifications and as per directions of the Engineer-in-Charge.
400
35
14000
... More
code39 - Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick /C.C wall,including necessary rawl plugs,Machine/NF screws etc., complete.4-5 Way.complete as per specifications and as per directions of the Engineer-in-Charge.
8
137
1096
... More
code40 - Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick /C.C wall,including necessary rawl plugs,Machine/NF screws etc., complete.6 Way.complete as per specifications and as per directions of the Engineer-in-Charge.
8
173
1384
... More
code41 - Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick /C.C wall,including necessary rawl plugs,Machine/NF screws etc., complete.8 Way.complete as per specifications and as per directions of the Engineer-in-Charge.
8
219
1752
... More
code42 - Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick /C.C wall,including necessary rawl plugs,Machine/NF screws etc., complete.10-12 Way.complete as per specifications and as per directions of the Engineer-in-Charge.
6
261
1566
... More
code43 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos.of machine screws,bolts nuts etc.,complete on the existing metal /PVC box. 8 Module
16
284
4544
... More
code44 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multi strand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010, 4 mm2.complete as per specifications and as per directions of the Engineer-in-Charge.
250
63
15750
... More
code45 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multi strand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010, 2.5mm2complete as per specifications and as per directions of the Engineer-in-Charge.complete as per specifications and as per directions of the Engineer-in-Charge.
150
42
6300
... More
code46 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multi strand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010, 1.5mm2.complete as per specifications and as per directions of the Engineer-in-Charge.
250
26
6500
... More
code47 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal Socket .complete as per specifications and as per directions of the Engineer-in-Charge.
20
236
4720
... More
code48 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch .complete as per specifications and as per directions of the Engineer-in-Charge.
65
102
6630
... More
code49 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 600W Dimmer.complete as per specifications and as per directions of the Engineer-in-Charge.
16
329
5264
... More
code50 - Supplying of.....feet-PVC Batten with integrated LED tube....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greaterthan 80.Power Input:220-240V @ 50/60Hz & Power factor greaterthan 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W.complete as per specifications and as per directions of the Engineer-in-Charge.
20
690
13800
... More
code51 - Supplying of.....feet-PVC Batten with integrated LED tube....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greaterthan 80.Power Input:220-240V @ 50/60Hz & Power factor greaterthan 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 36/40 W.complete as per specifications and as per directions of the Engineer-in-Charge.
20
1269
25380
... More
code52 - Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase&Neutral) & 1x1.0sqmm (Earthwire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments)with a 6Amps flush type SPcontrol switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch.complete as per specifications and as per directions of the Engineer-in-Charge.
15
285
4275
... More
code53 - Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase&Neutral) & 1x1.0sqmm (Earthwire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments)with a 6Amps flush type SPcontrol switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to outlet via switch box.complete as per specifications and as per directions of the Engineer-in-Charge.
15
379
5685
... More
code54 - Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase&Neutral) & 1x1.0sqmm (Earthwire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments)with a 6Amps flush type SPcontrol switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to outlet via switch box Long point above 6Mtr upto 10Mtr from tapping point to outlet via switch box.complete as per specifications and as per directions of the Engineer-in-Charge.
20
555
11100
... More
code55 - Supplying of.. TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50Hz 230V with hermetically sealed inverter compressor with air cooled condenser, latest R 410A/R-32 refrigerant fan motor, start & run capacitors, relay &over load protector internal unit, with one indoor & one outdoor unit The condense run it will be place dout side the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3cores heathed/PVC copper cable and a battery operated wireless remote unit. 5 star 2 Ton capacity
8
67399
539192
... More
code56 - Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 10 kVA ON LINE UPS.complete as per specifications and as per directions of the Engineer-in-Charge.
1
103570
103570
... More
code57 - Supplying, installation, testing & commissioning of 12VDC, Ah batteries in polypropylene container for U.P.S. Sealed maintenance free batteries. 100 AH capacity.complete as per specifications and as per directions of the Engineer-in-Charge.
12
12430
149160