Karnataka Slum Development Board Tender

... More
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Karnataka Slum Development Board - KSDB Tender

Works
Civil And Construction
Building Construction
Opening Date13 Feb 2025
Closing Soon28 Feb 2025
Tender Amount₹ 82,91,981.13 
Notes
Download

Costs

Summary

Construction Of Office Building At Bellary City Ward No.17 At Survey No.1/a2 & 1/b Of Gonal Town

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
004 - Reinforcement Steel (L/s 1% of total concrete) ---- With All Lead and Lift and as per the direction of Engneer-in-charge

12194.19

72

884078.775

... More
5.2 - K.P.W.D 5.2 (Vol. 2 Page No.9) Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- With All Lead and Lift and as per the direction of Engneer-in-charge

135

5543

748305

... More
1.10 - K.P.W.D 1.10 (Vol. 1 Page No.7) Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

592.17

122

72244.74

... More
1.11 - K.P.W.D 1.11 (Vol. 1 Page No.7) Supplying and filling in plinth with sand under floors, foundation of Bridges including watering, ramming, consolidating and dressing complete. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

313.92

2177

683403.84

... More
6.5 - K.P.W.D 6.5 (Vol. 2 Page No.13) Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 5.0 conforming to IS: 2222 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Non modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

116.19

8860

1029443.4

... More
8.3.2 - K.P.W.D 8.3.2 (Vol. 2 Page No.41) Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

840

276

231840

... More
8.1.2 - K.P.W.D 8.1.2 (Vol. 2 Page No.41) Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

1394.5

198

276111

... More
8.29 - K.P.W.D 8.29 (Vol. 2 Page No.45) Finishing walls with textured exterior paint of required shade : New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

840

208

174720

... More
8.33.1 - K.P.W.D 8.33.1 (Vol. 2 Page No.46) Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

636.5

118

75107

... More
9.12 - K.P.W.D 9.12 (Vol. 2 Page No.60) Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. 9.12.2 Size of Tile 600x600 mm ---- With All Lead and Lift and as per the direction of Engneer-in-charge

282.45

1087

307023.15

... More
9.39 - K.P.W.D 9.39 (Vol. 2 Page No.65) Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

33.75

1037

34998.75

... More
12.10 - K.P.W.D 12.10 (Vol. 2 Page No.99) Providing Teak wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

0.02

235649

4712.98

... More
12.12 - K.P.W.D 12.12 (Vol. 2 Page No.100) Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

0.06

75344

4520.64

... More
12.16 - K.P.W.D 12.16 (Vol. 2 Page No.100) Providing and fixing in position fully panelled Teak wood shutters for doors with , stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) ---- With All Lead and Lift and as per the direction of Engneer-in-charge

4.2

9479

39811.8

... More
12.18 - K.P.W.D 12.18 (Vol. 2 Page No.101) Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with, stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures ) ---- With All Lead and Lift and as per the direction of Engneer-in-charge

16.8

4026

67636.8

... More
12.90 - K.P.W.D 12.90 (Vol. 2 Page No.112) Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wallthickness of frame & sash shall be of 2mm 2.5mm. Maximum possible size 2419mm x 2200mm. (Thecost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- With All Lead and Lift and as per the direction of Engneer-in-charge

20.97

7240

151822.8

... More
12.57.3 - K.P.W.D 12.57,12.57.3 (Vol. 2 Page No.106) Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

6.3

4026

25363.8

... More
15.1 - K.P.W.D 15.1 (Vol. 2 Page No.133) Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charg ---- With All Lead and Lift and as per the direction of Engneer-in-charge

282.24

745

210268.8

... More
15.1 - Appendix I Additionalities for Formwork, Centering & Scaffolding Foundation ---- With All Lead and Lift and as per the direction of Engneer-in-charge

45.79

309

14162.847

... More
15.1 - Appendix I Additionalities for Formwork, Centering & Scaffolding Columns ---- With All Lead and Lift and as per the direction of Engneer-in-charge

19.18

494

9491.7984

... More
15.1 - Appendix I Additionalities for Formwork, Centering & Scaffolding Beams & Lintels ---- With All Lead and Lift and as per the direction of Engneer-in-charge

44.3

494

21923.184

... More
15.1 - Appendix I Additionalities for Formwork, Centering & Scaffolding Roof ---- With All Lead and Lift and as per the direction of Engneer-in-charge

46.07

494

22799.1216

... More
1.2 - K.P.W.D 1.2 (SREW, Page No.1) Concealed Conduit System. Supplying heavy gauge PVC conduit pipe 40 mm dia 2.5mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

200

106

21200

... More
1.2.1 - K.P.W.D 1.2.1 (SREW, Page No.1) Supplying heavy gauge PVC conduit pipe 19/20mm dia 2mm thick confirming to IS 2509 with suitable size bends, metal/ PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

200

61

12200

... More
1.2.2 - K.P.W.D 1.2.2 (SREW, Page No.1) Supplying heavy gauge PVC conduit pipe 25mm dia 2mm thick confirming to IS 2509 with suitable size bends, metal/ PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

260

70

18200

... More
1.3.1 - K.P.W.D 1.3.1 (SREW, Page No.1) Supplying heavy gauge PVC Conduit Pipe 19mm dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

250

75

18750

... More
1.3.2 - K.P.W.D 1.3.2 (SREW, Page No.1) Supplying heavy gauge PVC Conduit Pipe 25mm dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

60

80

4800

... More
2.2.1 - K.P.W.D 2.2.1 (SREW, Page No.3) Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3m from tapping point to out let via switch box. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

6

251

1506

... More
2.2.2 - K.P.W.D 2.2.2 (SREW, Page No.3) Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3m upto 6m from tapping point to out let via switch box. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

6

361

2166

... More
2.2.3 - K.P.W.D 2.2.3 (SREW, Page No.3) Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6m upto 10m from tapping point to out let via switch box. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

5

542

2710

... More
2.3.2 - K.P.W.D 2.3.2 (SREW, Page No.3) Wiring for lighting/ power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

200

26

5200

... More
2.3.3 - K.P.W.D 2.3.3 (SREW, Page No.3) Wiring for lighting/ power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

200

40

8000

... More
2.3.4 - K.P.W.D 2.3.4 (SREW, Page No.3) Wiring for lighting/ power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 mm2. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

200

59

11800

... More
3.4.1 - K.P.W.D 3.4.1 (SREW, Page No.5) Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 1-3Way. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

18

123

2214

... More
3.4.3 - K.P.W.D 3.4.3 (SREW, Page No.5) Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 6Way. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

18

212

3816

... More
3.4.4 - K.P.W.D 3.4.4 (SREW, Page No.5) Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 8Way. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

18

250

4500

... More
3.4.5 - K.P.W.D 3.4.5 (SREW, Page No.5) Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 10-12Way. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

15

325

4875

... More
3.5.1 - K.P.W.D 3.5.1 (SREW, Page No.5) Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc. complete on the existing metal/PVC box. 1 to 3 Module. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

18

152

2736

... More
3.5.3 - K.P.W.D 3.5.3 (SREW, Page No.5) Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc. complete on the existing metal/PVC box. 6 Module. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

18

244

4392

... More
3.5.4 - K.P.W.D 3.5.4 (SREW, Page No.5) Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc. complete on the existing metal/PVC box. 8 Module. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

18

302

5436

... More
3.5.6 - K.P.W.D 3.5.6 (SREW, Page No.5) Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc. complete on the existing metal/PVC box. 16 to 18 Module. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

18

403

7254

... More
3.6.1 - K.P.W.D 3.6.1 (SREW, Page No.5) Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

18

88

1584

... More
3.6.2 - K.P.W.D 3.6.2 (SREW, Page No.5) Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Two Way Switch. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

18

152

2736

... More
3.6.3 - K.P.W.D 3.6.3 (SREW, Page No.5) Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Three Way socket. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

18

162

2916

... More
3.6.4 - K.P.W.D 3.6.4 (SREW, Page No.5) Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

18

313

5634

... More
3.6.10 - K.P.W.D 3.6.10 (SREW, Page No.5) Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32A DP Switch. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

8

375

3000

... More
3.6.11 - K.P.W.D 3.6.11 (SREW, Page No.5) Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal Socket. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

8

249

1992

... More
3.10.2 - K.P.W.D 3.10.2 (SREW, Page No.6) Extra for supplying 4 mm thick white plastic plate and covering for junction boxes of size 110 mm conduit using necessary machine screws. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

23

12

276

... More
1.12 - K.P.W.D 1.12 (SREW, Page No.2) Supplying And Fixing Metal Fan Box with Round Hook. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

18

163

2934

... More
3.14.6 - K.P.W.D 3.14.6 (SREW, Page No.6) 6A Lamp Holder ---- With All Lead and Lift and as per the direction of Engneer-in-charge

18

63

1134

... More
11.11.3 - K.P.W.D 11.11.3 (SREW, Page No.38) Supplying & fixing of retrofit type LED bulb 7W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

26

148

3848

... More
11.3.2 - K.P.W.D 11.3.2 (SREW, Page No.34) Supplying of 2feet -PVC Batten with integrated LED tube 28W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

15

740

11100

... More
1.7.1 - K.P.W.D 13.7.1 (SREW, Page No.45) Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. On wall/ ceiling / Rafter / Girders ---- With All Lead and Lift and as per the direction of Engneer-in-charge

35

119

4165

... More
6.3.1 - K.P.W.D 6.3.1 (SREW, Page No.22) Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48"" Sweep (1200 mm) Regular model. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

15

2085

31275

... More
13.12 - K.P.W.D 13.12 (SREW, Page No.46) Extra length of GI pipe of class B 19mm dia for down rod. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

200

173

34600

... More
13.10 - K.P.W.D 13.10 (SREW, Page No.46) Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

18

162

2916

... More
5.17.4 - K.P.W.D 5.17.4 (SREW, Page No.13) Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A DP. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

18

1103

19854

... More
5.17.4 - K.P.W.D 5.17.4 (SREW, Page No.13) Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A TPN. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

18

1777

31986

... More
5.18.9 - K.P.W.D 5.18.9 (SREW, Page No.13) Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 12 Way SP & N. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

6

2067

12402

... More
5.20.3 - K.P.W.D 5.20.3 (SREW, Page No.13) Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V upto 300mA sensitivity on existing wood/panel board. 32-40 A 4 pole. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

8

2826

22608

... More
5.38 - K.P.W.D 5.38 (SREW, Page No.14) Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

14

464

6496

... More
5.40.2 - K.P.W.D 5.40.2 (SREW, Page No.15) Supplying 250A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., .complete. 4 x 30 x 10 mm Aluminium Strips. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

6

3072

18432

... More
5.42.2 - K.P.W.D 5.42.2 (SREW, Page No.15) Fabricating supplying and mounting MS box made out 16 SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

90000

-

34200

... More
3.9 - K.P.W.D 3.9 (SREW, Page No.6) Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N. F. screws. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

1200

-

312

... More
5.22 - K.P.W.D 5.22 (SREW, Page No.14) Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

6

407

2442

... More
5.22 - K.P.W.D 5.22 (SREW, Page No.14) Supplying, fixing and wiring 0 to 100 A Direct Reading AC analog type Ammeter. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

6

472

2832

... More
5.27 - K.P.W.D 5.27 (SREW, Page No.14) Supplying, fixing and wiring rotary selector switch suitable for Ammeter. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

6

178

1068

... More
5.28 - K.P.W.D 5.28 (SREW, Page No.14) Supplying, fixing and wiring rotary selector switch suitable for Voltmeter ---- With All Lead and Lift and as per the direction of Engneer-in-charge

6

146

876

... More
5.35 - K.P.W.D 5.35 (SREW, Page No.14) Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 A three phase 4 wire whole current class-1 Accuracy Energy Meter. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

6

5125

30750

... More
5.47 - K.P.W.D 5.47 (SREW, Page No.16) Supplying and fixing Microprocessor based Electronic timer (without contactor, Din Mounting using necessary bolts, nuts and washers etc.,.) 3-120sec setting. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

6

2079

12474

... More
12.2.1 - K.P.W.D 12.2.1 (SREW, Page No.39) Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

6

239

1434

... More
1.2 - Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm (Depth upto 1.50m not exceeding 1.5m in width ) trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required, utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata.All kinds of soils. Depth upto 1.50m ---- With All Lead and Lift and as per the direction of Engneer-in-charge

58

324

18827.96

... More
1.2 - Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications ---- With All Lead and Lift and as per the direction of Engneer-in-charge

40

198

7929.6

... More
1.2 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction ofEngineer in Charge. Internal work - Exposed on wall32 mm nominal dia Pipes ---- With All Lead and Lift and as per the direction of Engneer-in-charge

30

495

14868

... More
1.2 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 32 mm nominal dia Pipes ---- With All Lead and Lift and as per the direction of Engneer-in-charge

85

460

39177.35

... More
1.2 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40 mm nominal dia Pipes ---- With All Lead and Lift and as per the direction of Engneer-in-charge

60

591

35460

... More
1.2 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50 mm nominal dia Pipes ---- With All Lead and Lift and as per the direction of Engneer-in-charge

90

893

80398.8

... More
1.2 - Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 32 mm dia PVC Elbows Each 21 ---- With All Lead and Lift and as per the direction of Engneer-in-charge

90

26

2341.8

... More
1.2 - Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments32 mm dia PVC Tee ---- With All Lead and Lift and as per the direction of Engneer-in-charge

15

39

594.75

... More
1.2 - Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments32 mm dia PVC BEND ---- With All Lead and Lift and as per the direction of Engneer-in-charge

34

44

1516.4

... More
1.2 - 15 mm nominal bore, 90 mm long, weighing not less than 93 g ---- With All Lead and Lift and as per the direction of Engneer-in-charge

30

299

8995.2

... More
1.2 - Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

60

11

669

... More
1.2 - Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter ---- With All Lead and Lift and as per the direction of Engneer-in-charge

40

360

14422

... More
1.2 - Equipments as per selection ---- With All Lead and Lift and as per the direction of Engneer-in-charge

1

89994

89994

... More
1.2 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- With All Lead and Lift and as per the direction of Engneer-in-charge

7.61

7420

56469.0157

... More
1.2 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (For Foundations) ---- With All Lead and Lift and as per the direction of Engneer-in-charge

8.13

8412

68395.7388

... More
1.6 - Providing Size Stone masonry with hard stone in foundation & plinth withCement mortar 1:6 (1 cement : 6 coarse sand) ---- With All Lead and Lift and as per the direction of Engneer-in-charge

3.78

7915

29922.3666

... More
1.2 - Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

8.78

3533

31025.2714

... More
1.2 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- With All Lead and Lift and as per the direction of Engneer-in-charge

447.93

700

313568.9172

... More
1.1 - Miscellaneous works (Watchman, Water Charges & Material Shifting 10% of Gross) ---- With All Lead and Lift and as per the direction of Engneer-in-charge

1

532006

532006.97

... More
1.1 - Consultancy Charges (3% of Gross) ---- With All Lead and Lift and as per the direction of Engneer-in-charge

1

189117

189117.86



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.