Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Karnataka Power Transmission Corporation Limited - KPTCL Tender

Works
Civil And Construction
Energy, Oil and Gas
Road Construction
Electrical Works
Opening Date6 Dec 2024
Closing Soon6 Jan 2025
Tender Amount₹ 26,74,57,031.21 
Notes
Download

Costs

Summary

Establishing 1x20mva, 110/33kv And 2x20 Mva,110/11kv Sub-station At Inchala Village And Construction Of 110 Kv Dc Line Using Panther Conductor From 110kv Hosur Sub-station

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
SS4 - CIRCUIT BREAKER : SF6 Gas circuit breaker with Semi-Pneumatic/Pneumatic operated/Spring type operating mechanism, including mounting Structures arrangements with rigid, bi-metallic terminal connectors complete suitable for Moose ACSR Conductor and mounting structures complete as per technical specifications. A. 145kV, 3150A, 40 kA Class i) For 110 kV line (2Nos each for 110kV Inchala and Hosur S/s) ii) For 110/11KV Transformer (2Nos) iii) For 110/33KV Transformer (1No)

7

718000

5026000

... More
SS5 - B. 33kV, 800A, 25kA class i) For 33kV line (2Nos) ii) For 33kV side of 110/33kV transformer

3

598000

1794000

... More
SS6 - ISOLATORS : Isolators including marshalling box and suitable terminal connectors, as required as per technical specification with solid core cylindrical post insulators complete set. A) 110KV, 1250A,40KA Class Double Break Manually operated isolator with terminal connectors suitable for Moose ACSR/75mm/63mm Al tube 1) Upright mounting type with Earth switch LPH 4600mm (2Nos each for 110kV Inchala and Hosur S/s) (Refer Techno-Commercial sheets for split up details)

4

381150

1524600

... More
SS7 - 2) Upright mounting type without Earth switch LPH 4600 mm (1No for 110kV Inchala and 2Nos for Hosur S/s) (Refer Techno-Commercial sheets for split up details)

3

321860

965580

... More
SS8 - 3) Upright mounting type without earth switch LPH 6350mm Note : 1. Terminal connectors for Isolators for Inchala : Rigid type suitable for Moose ACSR - 30 Nos Flexible type suitable for 75mm Al.pipe - 3Nos Flexible type suitable for 63mm Al.pipe - 15Nos 2. Terminal connectors for Isolators for Hosur : Rigid type suitable for Moose ACSR - 18 Nos Flexible type suitable for 63mm Al.pipe - 6Nos

5

329120

1645600

... More
SS9 - B) 33 KV, 800A, 25KA Class Double Break Manually operated isolator With terminal connectors suitable for DRAKE ACSR. i) Upright mounting type with Earth switch.(Live point height 3750mm)

2

84700

169400

... More
SS10 - ii)Upright mounting type without Earth switch. (Live point height 3750mm)

1

70180

70180

... More
SS11 - iii)Upright mounting type without earth switch. (Live point height 4750mm) Terminal connectors for Isolators : Rigid type suitable for Drake ACSR- 30 Nos Flexible type suitable for 38 mm Al.pipe - 12Nos

4

95590

382360

... More
SS12 - B)11KV isolator i) 11KV isolator Double break 400A, 25KA capacity with rigid bi-metalic terminal connectors suitable for coyote ACSR for capacitor bank.

4

21260

85040

... More
SS13 - ii) 11KV isolator Single break 400 A, 25 KA capacity with Roster switch with rigid bi-metalic terminal connector suitable for coyote ACSR.

11

14956

164516

... More
SS14 - CURRENT TRANSFORMER : Current transformers including marshalling boxes, Single phase,oil filled outdoor type with rigid bimetallic terminal connectors suitable for Moose ACSR conductor complete as per technical specifications. i)110 kV class, 40 KA, CT of ratio 200-100/ 1-1-1A for Transformers Core - 1 : Vk-400 V at 200A, Rct 2 ohm at 200/1A, Accuracy class PS-Dist/Dif Core- 2 : 10 VA, Accuracy class 0.2s- Metering Core - 3 : 30 VA, Accuracy class 5P20-Back up

9

138000

1242000

... More
SS15 - ii)110 kV class, 40KA, CT of ratio 600-400/ l-l-lA for Tr. Lines. Core-1: Vk-1100 V at 600A, Rct 5 ohm at 600/1A, Accuracy class PS-Dist/Dif Core- 2 : 10 VA, Accuracy class 0.2s- Metering Core - 3 : 30 VA, Accuracy class 5P20-Back up

12

139000

1668000

... More
SS16 - iii) 33 kV class, 25 KA, CT of ratio 400-200/ 1-1-1A for Line Core - 1 : Vk-240 V, Rct 5 ohm at 400/1A, Accuracy class PS-Dist/Dif Core- 2 : 10 VA, Accuracy class 0.2s- Metering Core - 3 : 30 VA, Accuracy class 5P20-Back up

6

43000

258000

... More
SS17 - iv) 33 kV class, 25 KA, CT of ratio 400-200/ 1-1-1A for Tranfrs Core - 1 : Vk-240 V, Rct 5 ohm at 400/1A, Accuracy class PS-Dist/Dif Core- 2 : 10 VA, Accuracy class 0.2s- Metering Core - 3 : 30 VA, Accuracy class 5P20-Back up

3

43000

129000

... More
SS18 - v) 33 kV Class, 31.5 kA, NCT of ratio 400-200/1-1-1A for REFR Protection (of similar rating and ratio as that of Incomer of 33 kV CT at 33 kV side of trfr) with terminal connector suitable for 2 Nos. of Copper flats as per technical specifications.

1

42350

42350

... More
SS19 - vi) 11 KV Class, 25KA, NCT of ratio 1200-800/1-1-1A for REFR protection( of similar rating and ratio as that of Incomer of 11KV Switchgear) with terminal connector suitable for 2 Nos. of suitable Copper flats as per technical specifications. Note : 1) For details refer Annexure 3 : Technical parameters of Currnet Transformers for Type and rating at the end of this schedule. 2) All the current transformer in each KV Class shall be of One and the same make for interchangeability and relability of performance 3) The make and characteristic of 11KV NCT should be the same as that of the incommer CT of 11KV Switch gear only.

2

57999

115999.96

... More
SS20 - VOLTAGE TRANSFORMERS : Single phase, oil filled outdoor type with rigid bimetallic terminal connectors suitable for Moose ACSR with marshalling box KIOSK etc., complete as per Technial specification:  a) 110 kV class 110kV/RT3/110V/RT3/ 110V/RT3/ 110V/RT3 Core - 1 : 300 VA, Accuracy class 0.2. Protection Core - 2 : 200 VA, Accuracy class 3P-Metering Core - 3 : 50 VA, Accuracy class 3P. Open delta

3

154000

462000

... More
SS21 - b) 33 kV Class, 33 kV/ RT3/110 V/RT3-110 V/RT3-110 V/RT3 Core - 1 : 300 VA, Accuracy class 0.2 - Protection Core - 2 : 200 VA, Accuracy class 3P - Metering Core - 3 : 50 VA, Accuracy class 3P - Open delta

3

47000

141000

... More
SS22 - SURGE ARRESTOR : (Procelain/Polymer) metal oxide, gapless type with rigid bimetallic terminal connectors suitable for Moose ACSR as per technical specifications.. i) 96kV, 10kA, Class- III, SM type -For Transformers (9Nos) ii) 96kV, 10kA, Class-III, SM type -For overhead Lines (6Nos each for 110kV Inchala & Hosur S/s) (Refer Techno-Commercial sheets for split up details)

21

42000

882000

... More
SS23 - iii) 30 kV, 10 KA, class - III, Metal oxide type-For Transformers (3Nos) iv) 30 kV, 10 KA, class - II, Metal oxide type-For OH line (6Nos)

9

5000

45000

... More
SS24 - 9 kV, 10 KA with connector and clamp Note : For 11kv side of 20MVA Trfs 6Nos

39

920

35880

... More
SS25 - Control and Relay panel complete : Simplex type Control and Relay panel complete as per technical specifications a) For Power Transformer 110/11 kV

2

631620

1263240

... More
SS26 - b) For Power Transformer 110/33 kV

1

778030

778030

... More
SS27 - c) For 110kV Transmission lines

4

456170

1824680

... More
SS28 - d) For 33kV Transmission lines Note: 1.All the C&R panels and associated panels shall be of one and the same make for uniformity and interchangability of components 2. The accuracy class of metering core of CTs and VTs and ETV meter of C&R Panel shall be 0.2s accuracy class irrespective of what has been indicated else where in the bid document. 3. The electronic trivector meters with ABT & TOD features, DLMS protocol energy meter has to be provided.

2

214170

428340

... More
SS29 - Total Weight of fabricated out of galvanised Station structures & Mounting Structures,Lighting Mast & Street Lighting Structure (excluding Bolts & Nuts) as per technical specifications (Refer Techno-Commercial sheets for split up details)

46.8524

130000

6090812

... More
SS30 - Total Weight of galvanised Bolts & Nuts of Station structures & Mounting Structures,Lighting Mast & Street Lighting Structure as per technical specifications (Refer Techno-Commercial sheets for split up details)

2.8268

142780

403610.504

... More
SS31 - 11kV ODS and take of structure Supplying of Double pole structure with 9.5 Mts, RCC poles WL 300 Kgs for mounting 11kV,400 A Roaster Isolators and 9kV,10KA surge arrestor (3 No.) complete set.

11

26922

296142

... More
SS32 - BUS BAR FORMATION : a) Moose ACSR

550

531

292050

... More
SS33 - b) Drake ACSR

200

410

82000

... More
SS34 - b) Coyote ACSR

50

146

7300

... More
SS35 - Rigid bus with taps & clamps: (i) Aluminium Tube conforming to 6340 WP of IS-5082/1969 (BS 1600-Sch.40) of following nominal diameter a) 75 mm size

120

1586

190320

... More
SS36 - b) 63 mm size for connecting isolator to vertical tap

144

1452

209088

... More
SS37 - ii) Straight taps suitable for 63mm Aluminium tube (BS-1600) of 1750mm vertical height for vertical portion & cross bus on 110KV side with rounded off end.

15

3736

56040

... More
SS38 - iii) Post insulator clamps suitable for 75mm Aluminium pipe & Post insulator solid core type - 110kV side a) Rigid type

6

1868

11208

... More
SS39 - b)Expansion Type

6

5322

31932

... More
SS40 - c) Sliding type

11

2109

23199

... More
SS41 - iv) Post insulator clamps suitable for 63mm Aluminium pipe & Post insulator solid core type - 110kV side a) Rigid type

3

1753

5259

... More
SS42 - b) Sliding type

3

1481

4443

... More
SS43 - v) Corona Bell Suitable for Aluminium Pipe of size 75mm on 110 kV

9

679

6111

... More
SS44 - vi) End Cap for 63 mm

9

617

5553

... More
SS45 - vii) Terminal connector suitable for 75mm Al. tube to Moose (Bus)

3

2191

6573

... More
SS46 - 33 kV Side: i) Aluminium pipe conforming to 6340 WP of IS -5082 /1969 of Diameter 50 mm

48

1228

58944

... More
SS47 - ii) 38 mm Size vertical taps

72

650

46800

... More
SS48 - iii) Staright taps for 38 mm for 33 kV Side

6

2061

12366

... More
SS49 - Post Insulator Clamps for 50mm Tube & 33 kV Post Insulator i) RigidType

3

1629

4887

... More
SS50 - ii) Sliding Type

3

1705

5115

... More
SS51 - iii) Corona Bell for 50 mm tube

6

587

3522

... More
SS52 - INSULATORS: Post Insulators-Cylindrical Solid Core Insulators as per technical specifications: i) 110kV 1 Unit/Stack

39

12007

468273

... More
SS53 - ii) 33kV 1 Unit/Stack

6

3639

21834

... More
SS54 - DISC INSULATORS WITH HARDWARES as per technical specification : i. 90 KN Disc Insulators 3 units each suitable for Drake ACSR (Refer Techno-Commercial sheets for split up details)

36

591

21276

... More
SS55 - HARDWARES : ii. Bolted Type Single Tension Clamp and hardware suitable for Drake ACSR.( 33 kV Side).

6

2577

15462

... More
SS56 - iii. Bolted Type Single Suspension Clamp suitable for Drake ACSR. (On LV Side of tfr).

6

1566

9396

... More
SS57 - INSULATOR HARDWARE & CLAMPS as per technical specification: iv. C type Wedge connectors Moose - Panther (Line)

24

5654

135696

... More
SS58 - v. C Type wedge connector suitable for Moose -Drake

3

3378

10134

... More
SS59 - vi. C Type wedge connector suitable for Drake -Drake (33 kV Side )

12

2462

29544

... More
SS60 - vii.C Type wedge connector suitable for Drake -Coyote (33 kV Side )

12

2334

28008

... More
SS61 - viii. Post insulator clamp suitable for Moose ACSR and 110kV Solid core insulator

9

847

7623

... More
SS62 - ix. Post insulator clamp suitable for Drake ACSR and 110kV Solid core insulator

1

1039

1039

... More
SS63 - Auxilliary Transformer : 1.Supply of Station Auxiliary Transformer-copper winding with oil, outdoor type 100 kVA, 11 kV/433 V, 3 Ph, Vector group Dyn 11 off load tap changer (with 5 taps) with step voltage of 2.5% along with other accessories as per technical specification.

1

349196

349196

... More
SS64 - 2. LTAC Panel (indoor): LTAC panel (Indoor) 415 V as per technical specification, comprising of Volt meter, Ammeter, 1 I/C MCCB 200A + 2 nos 3 phase, 63A OG SFU + 2 nos 3 phase, 32A OG SFU + 6 nos 3 phase 16A SFU etc., complete as per technical specification.

1

85910

85910

... More
SS65 - 3. AC Distribution box (out door ): AC Distribution box (outdoor) 415 V, Single front type with 6 terminals ,one I/C of 100 A MCCB 20 KA+ 6 O/G 16 A MCB +1 O/G of 100 A HRC Fuse panel complete as per technical specification.

3

72600

217800

... More
SS66 - 4. Supplying of DP structure with 9.5 mtr RCC poles, 11 kV 400 A double break isolators, 9 kV, 10 KA surge arrestor (3 No.), H-Frame along with DOLO/HG fuse unit, LTprotection kit/LTD box, LT Trivector meter complete set with all accessories for auxilliary transformer

1

78727

78727

... More
SS67 - LT Power armoured UG Cable as per specification: a) 1.1 kV class 4 X 95 Sq mm L T Aluminium Cable with glands/lugs/ferrules

200

762

152400

... More
SS68 - b) 1.1 kV class 4X 25 Sq mm Copper Cable with glands/lugs/ferrules

200

866

173200

... More
SS69 - c) 1.1 kV class 4X 10 Sq mm Copper Cable with glands/lugs/ferrules

400

375

150000

... More
SS70 - Station Battery & Battery Charger: A) Station Battery : 110 V, 200 AH Battery set (Plante/Grid/Nickel Cadmium Type) as per Technical Specifications.

1

617000

617000

... More
SS71 - B) Station Battery Charger : Battery charger suitable for 1X110V, 200AH, Battery set (Plante/Grid/Nickel Cadmium Type) -15A float and 30A boost (with float and boost battery charger as per technical specification).

1

173000

173000

... More
SS72 - C) LT DC Distribution panel ( Indoor) : LT DC Distribution panel ( Indoor) comprising of Earth fault indicator, Indication circuit for AC main failure, 1 No 100A SFU for IC + 12 nos., 32A SFU for OG etc,. complete as per Technical specification .

1

52030

52030

... More
SS73 - 1.1 KV class PVC insulated armoured copper control cables of sizes,with Lugs/Ferrules/Gland as per technical specifications: i) 19 Core 2.5 Sq.mm.

4.5

560000

2520000

... More
SS74 - ii) 10C x 2.5 Sq.mm

4

332000

1328000

... More
SS75 - iii) 4 Core 6.0 Sq.mm.

4.7

247000

1160900

... More
SS76 - iv) 4 Core 2.5 Sq.mm.

4

151000

604000

... More
SS77 - v) 2 Core 6 Sq.mm. (Qty of SS163 is added and Refer Techno-Commercial sheets for split up details)

4.3

154000

662200

... More
SS78 - vi) 2 Core 2.5 Sq.mm.

1.7

99000

168300

... More
SS80 - 2. 11KV U.G. Cable with the required cable terminations at both ends. a) One run of 11kV, XLPE 95 sq.mm Al., 3 core cable - (to be run for Auxiliary Transformers from 11KV switch Gear to Auxiliary Transformer).

60

889

53378.4

... More
SS81 - b)11KV XLPE cable, 1000Sq. mm.Aluminium cable from 110/11KV transformers to 11KV Switchgear.

650

1231

800150

... More
SS82 - c)11KV XLPE cable, 240Sq. mm. Aluminium cable 3 Core to be run from 11KV Switchgear to 11kV take off DP Structure.

650

1656

1076432.5

... More
SS83 - 3. Cable Termination kits suitable for following sizes as per Technical Specification. A. Indoor type: i) Heat shrinkable type Cable termination kits suitable for 3 x 95 Sq.mm XLPE cable

1

3744

3744

... More
SS84 - ii) Heat shrinkable type Cable termination kits suitable for 3 x 240 Sq.mm XLPE cable

15

4691

70365

... More
SS85 - iii) Heat shrinkable type Cable termination kits suitable for 1 x 1000 Sq.mm XLPE cable

14

3808

53312

... More
SS86 - B. Outdoor type: i)Heat shrinkable type Cable termination kits suitable for 3 x 95 Sq.mm XLPE cable

1

4067

4067

... More
SS87 - ii) Heat shrinkable type Cable termination kits suitable for 3 x 240 Sq.mm XLPE cable

15

5318

79770

... More
SS88 - iii) Heat shrinkable type Cable termination kits suitable for 1 x 1000 Sq.mm XLPE cable

14

4060

56840

... More
SS89 - Equipments for establishing SCADA Communication as per KPTCL Specification i) Remote Terminal Unit (RTU)

1

986150

986150

... More
SS90 - ii) Data Concentrator Unit (DCU)

1

37510

37510

... More
SS91 - iii) 2kVA online UPS (230V AC 1phase 50Hz) with battery set

1

168190

168190

... More
SS92 - iv) Multi Functional Transducer (MFT) 0.2S class including labour

2

4875

9750

... More
SS93 - v) Opto Coupler (220 or 110V DC) including labour

2

1312

2624

... More
SS94 - iv) Supply of Power cables for SCADA a) Current Cables-Copper Core with c/s 4.0 sq.mm Multistrand 4 Core

60

177

10620

... More
SS95 - b) Voltage Cables-Copper Core with c/s 2.5 sq.mm Multistrand 4 Core

30

151

4530

... More
SS96 - c) Signal Cables-armoured Copper Core with c/s 0.5 sq.mm Multi strand 10 Core

520

143

74360

... More
SS97 - v) Supply of Control Cables for SCADA a) Supply of Control Cables- Copper Core with c/s 1.5 sq.mm Multi strand 10 Core

170

155

26350

... More
SS98 - b) Supply of Cables-Copper Core with c/s 4.0 sq.mm Multi strand 3 Core for AC input to UPS & UPS to RTU,conforming to KPTCL specifications.

15

159

2385

... More
SS99 - c) Supply Cables-Copper Core with c/s 32.0 sq.mm Multi strand for Battery conforming to KPTCL specifications Note: Satellite communication required will be arranged by SLDC

30

380

11400

... More
SS100 - Capacitor Bank : Design, Engineering, Suppy, Erection (including civil works), Testing & commissioning of 2.9MVAR, 12.1KV capacitor Bank, Star connected, Double bank with internal fuses ternimal connectors with suitable neutral CT on nuetrakl side and station class LA's, 0.2% series reactor on neutral side with mounting structure for NCT, capacitor bank, station class LA's, series reactor and with 10% spare capacitors etc.,complete as per specification.

4

538450

2153800

... More
SS101 - FIRE FIGHTING EQUIPMENTS WITH NECESSARY MOUNTING STANDS i) Mechanical Foam Type Extinguisher : a) 50 Liters

8

10112

80896

... More
SS102 - b) 09 Liters

6

4118

24708

... More
SS103 - ii) Water type (gas pressure type) 9 Ltr. capacity

8

2503

20024

... More
SS104 - iii) Carbon Dioxide Type 4.5 Kgs capacity

8

8691

69528

... More
SS105 - iv) Sand type a) G.I Buckets15 Ltr. capacity

20

603

12060

... More
SS106 - b) Steel stands for above to have 4 buckets to each station

5

2362

11810

... More
SS107 - Maintenance Tools and Plant. 1. Portable (Mobile) Oil Pump (1/2 HP Airpump 500 to 1000 gallons)

1

20247

20247

... More
SS108 - 2. Telescopic ladder aluminium 6 mtr.height

1

22622

22622

... More
SS109 - 3. Ring spanner set

1

880

880

... More
SS110 - 4.Tube spanner set

1

1435

1435

... More
SS111 - 5. Pipe wrench 24 inch

2

1250

2500

... More
SS112 - 6. Pipe wrench 18 inch

2

692

1384

... More
SS113 - 7. Hydraulic crimping tools up to 1000 Sq.mm

1

62013

62013

... More
SS114 - 8. Rubber hand gloves (15KV Tested)

3

293

879

... More
SS115 - 9. Rechargeble 5W LED Hand Torch

4

1279

5116

... More
SS116 - 10. Insulated cutting plier 12 inch size

3

393

1179

... More
SS117 - 11.Insulated cutting plier 8 inch size

3

236

708

... More
SS118 - 12.Live line tester 500V AC/DC

2

311

622

... More
SS119 - 13. Screw driver 18 inch

3

223

669

... More
SS120 - 14. Screw driver 12 inch

3

75

225

... More
SS121 - 15. Hammer 8 Ibs

2

497

994

... More
SS122 - 16. Hammer 2 Ibs

2

249

498

... More
SS123 - 17. Chain pully block 5 ton capacity

1

41836

41836

... More
SS124 - 18. Hydraulic jack 5 ton capacity

4

7048

28192

... More
SS125 - 19. Pipe derrick Suitable for 3Mt and lift of 6Mtrs Height

1

27831

27831

... More
SS126 - 20. Allen keys

1

478

478

... More
SS127 - 21.Box spanners

1

4467

4467

... More
SS128 - 22.Transil oil dielectric break down test kit (with 2.5 mm gap 0-60 kV) Tester

1

101535

101535

... More
SS129 - 23.Insulation Tester Digital Type (megger) 2.5 to 5KV

1

55308

55308

... More
SS130 - 24.Insulation Tester (megger) 500V

1

17606

17606

... More
SS131 - 25.SF6 Gas leak detector

1

65242

65242

... More
SS132 - 26.Multimeter Electro Mechanical Type

1

3674

3674

... More
SS133 - 27.Multimeter Electronic Type

1

7991

7991

... More
SS134 - 28.Hydrometer

1

658

658

... More
SS135 - 29.DC voltmeter range -5V to +5V

1

2700

2700

... More
SS136 - 30.Hydrometer syring suitable for vent holes

1

900

900

... More
SS137 - 31.Specific gravity correction chart

1

900

900

... More
SS138 - 32.Wall mounting type holder for hydro meter

1

2700

2700

... More
SS139 - 33.Thermometer with wall mounting holder

1

2700

2700

... More
SS140 - 34.Rubber appron

1

1912

1912

... More
SS141 - 35.Pippette

1

788

788

... More
SS142 - 36.Protective goggles

1

900

900

... More
SS143 - 37.Acid resisting jars (4 pint capacity)

1

900

900

... More
SS144 - 38.Rubber shoes knee height

2

2138

4276

... More
SS145 - 39.Glass funnel

2

676

1352

... More
SS146 - 40.Grounding sticks expandable upto 18 ft

6

1755

10530

... More
SS147 - Miscellaneous items: 1. Rubber mats 2000mm X 1000mm X 12mm size tested for 15KV class

8

1900

15200

... More
SS148 - 2. First aid box

1

600

600

... More
SS149 - 3. Shock treatment charts hard board laminated with colured pictures & Literatures both in kannada & English

1

2000

2000

... More
SS150 - 4. Water filter/water purifier wall mounting type (Aqua guard type)

1

10000

10000

... More
SS151 - 5. Sub-station name board duly painted

1

9000

9000

... More
SS152 - 6. Fixograph of size 1.5m x 2.5m with Engilsh/Kannda alphabets

1

5000

5000

... More
SS153 - 7. Brass cupboard lock 6 levers (best make of approved quality) 75 mm size

5

210

1050

... More
SS154 - 8. Danger board (probhited) with support structure in front of the gate

1

2000

2000

... More
SS155 - 9. Equipments name plates & earthing name plates including fixing at outdoor yard.

124

398

49352

... More
SS156 - Furniture for Control Room Staff and Maintenance Staff: 1. Steel Almirahs 6.5 Feet

2

8000

16000

... More
SS157 - 2.Steel Almirahs 6.5 Feet with glass panel doors

1

8000

8000

... More
SS158 - 3.Officers Tables

2

6400

12800

... More
SS159 - 4.Steel Slotted Angle rack(big size)

4

2200

8800

... More
SS160 - 5.Steel Slotted Angle rack(small size)

4

1400

5600

... More
SS161 - 6.Steel dust bins

4

400

1600

... More
SS162 - 7.Executive revolving chairs

2

7000

14000

... More
SS163 - 8. S' Type arm chairs

6

1800

10800

... More
SS164 - 9.Steel folding chairs

4

1100

4400

... More
SS165 - Station Yard Lighting (Out Door) (To be designed, assessed & quoted by the bidder) Supply and installation/Fixing/Provision of Outdoortype Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shockproof, IP65 (WeatherProof), rustproof, dustproof, waterproof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase/Three Phase Energy Metering suitable base plate and having a provision for Fuse/ MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility,Timer,Contactor, 2 Way head frame with diecast LM-6 pulleys ,stainless steel axle,Phosphorus Bronze bearing bush press-fitted with separate guides for 2 runs of 5 mm dia,stainless steel wire rope of AIS I304 grade 7/19-core, Suitable reversible geared motor operating on 230/415V,50Hz,etc., as per techical specification.

2

65540

131080

... More
SS167 - Supply of LED Street light luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material LED streetlight 200W Note: Lightning/Lighting Mast (LM) tubular type are proposed for lightning protection and for illumination of the station Yard. The quantity of lightning / lighting mast indicated are located such that the entire station yard with equipments is protected against lightning. However any additional lighting masts may be provided for sufficient illumination and lightning protection (DSLP)of yard, if necessary. The design of lighting outdoor & indoor is also in the scope of the bidder as specified elsewhere in the technical specification. The scope also includes supply & erection of lighting fixtures, lighting mast panels with timer, contactor, control cable, Motorized hoist etc. Suitable 2.5M Lightning spikes shall be provided on top of GIS building for Lightning protection. The Design of lighting outdoor & Indoor in station yard and GIS buildings etc. is in the scope of bidder as specified in the technical specification.

12

19094

229128



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.