Karnataka Power Transmission Corporation Limited Tender
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
Costs
EMD
₹ 2,00,000Document Cost
Refer DocumentsTender Fee
₹ 3,020
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
KPTCL/2023-24/TL/WORK_INDENT452Tender No
KPTCL/2023-24/TL/WORK_INDENT452Tender Authority
Karnataka Power Transmission Corporation Limited ViewPurchaser Address
-Website
http://http://www.kptcl.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Techno-Commercial Worksheet
Instructions to Tenderers
Technical Information / Worksheet
BOQ Items
Earth wire -7-3.15mm Ground wire Plain Terrian
0.03
-
-
Single Tension string of 8 units 90KN each along with hardware for Lynx ACSR and arcing horn of Stack sets
15
-
-
Double Tension string of 8 units 90KN each along with hard ware for Lynx ACSR and arcing horn of Stack sets
3
-
-
Single Suspension string of 7 units 90KN each.along with hardware for Lynx ACSR and arcing horn of Stack sets
3
-
-
Double Suspension String of 7 Units 90KN each along with hardware for Lynx ACSR and arcing horn of Stack sets
9
-
-
M S C Joints suitable for Lynx ACSR
2
-
-
Pre formed armour rods suitable for Lynx ACSR
12
-
-
Repair sleeves suitable for Lynx ACSR
2
-
-
P G Clamps suitable for LYNX ACSR
18
-
-
Vibration dampers for Lynx
42
-
-
P G Clamps suitable for GROUND ACSR
2
-
-
Single Tension clamps (bolted type) suitable for Ground conductor
2
-
-
FOR LINE-CIRCUIT BREAKER-SF-6 Gas circuit breaker with semi-pneumatic - pneumatic operated - spring type operating mechanism including mounting arrangements R bi-metallic terminal connector complete suitable for Drake ACSR and mounting structures.
110 kV, 1250 A, 31.5 KA SF6 CB
1
-
-
ISOLATORS-110 kV, 1250 A, 40 KA class double break manually operated isolator with solid core insulators Upright mounting type with Earth switch.LPH 4600mm
1
-
-
ISOLATORS-110 kV, 1250 A, 40 KA class double break manually operated isolator with solid core insulatorsUpright mounting type without Earth switch.LPH 4600mm
1
-
-
CURRENT TRANSFORMER-Current transformer Single phase, oil filled outdoor type with R bimetallic terminal connectors suitable for drake ACSR-110 kV class, 31.5 KA, CT of ratio 400 - 200- 1-1-1A For metering- Accuracy 0.2s, Burden 10 VA
For backup protection- Accuracy 5P20. Burden 30 VA
For differential -Distance protection PS class (for LINES)
3
-
-
SURGE ARRESTOR (Procelain housing) metal oxide, Gapless type with R bimetallic connectors suitable for drake ACSR.96 kV, 10 KA, class - II, Heavy duty Metal oxide type
3
-
-
Control and Relay Panel complete Simplex-110kV Line Panel
1
-
-
STATION STRUCTURES-110 kV Station Structure fabricated out of galvanised iron. Column type 1T1 with peak. (0.956 MT per tower)
1
-
-
STATION STRUCTURES-110 kV Station Structure fabricated out of galvanised iron. Beam type 1B1(0.504 MT per tower)
1
-
-
MOUNTING STRUCTURES-110 kV Isolators. (0.76 MT per Structure)
2
-
-
MOUNTING STRUCTURES-Current transformer. 110 kV CT & 33kV NCT's, 11 kV NCT's.(0.1490 MT per Structure)
3
-
-
MOUNTING STRUCTURES-Lightening arrestors. 110 kV . (0.072 MT per Structure)
3
-
-
MOUNTING STRUCTURES-Pedestal insulators, 110 kV (0.147 MT per Structure)
1
-
-
Drake ACSR FOR BUS BAR FORMATION
100
-
-
7-3.15 mm Ground wire FOR BUS BAR FORMATION
50
-
-
Post insulator Solid core Insulator 110 kV
1
-
-
Single Tension string using 8 units of each 11kV, 90 KN Disc Insulators along with Bolted Type Tension Clamp and Hardware suitalbe for LYNX ACSR (110 kV Line Side)
3
-
-
HARDWARES-Wedged clamp suitable for Drake-Drake
6
-
-
HARDWARES-Wedged clamp suitable for Lynx -Drake
6
-
-
HARDWARES-Post insulator clamp suitable for Single Drake ACSR. 127-76 mm 110 kV
1
-
-
PVC insulated Copper Control Cable with Lugs - Ferrules. 1.1 KV class. Size of cable 19 Core 2.5 Sq.mm. Copper Control Cables
300
-
-
PVC insulated Copper Control Cable with Lugs - Ferrules. 1.1 KV class. Size of cable 2 Core 2.5 Sq.mm. Copper Control Cables
500
-
-
PVC insulated Copper Control Cable with Lugs - Ferrules. 1.1 KV class. Size of cable 4 Core 6.0 Sq.mm. Copper Control Cables
500
-
-
PVC insulated Copper Control Cable with Lugs - Ferrules. 1.1 KV class. Size of cable 4 Core 4.0 Sq.mm. Copper Control Cables
250
-
-
PVC insulated Copper Control Cable with Lugs - Ferrules. 1.1 KV class. Size of cable 4 Core 2.5 Sq.mm. Copper Control Cables
600
-
-
For establishing SCADA Communication Cables-Supplying and Laying-Current Cables-Copper Core with c-s 4.0Sq.mm Multi Strand 7 Core
50
-
-
For establishing SCADA Communication Cables-Supplying and Laying-Current Cables-Copper Core with c-s 2.5Sq.mm Multi Strand 4 Core
50
-
-
For establishing SCADA Communication Cables-Supplying and Laying-Current Cables-armoured Copper Core with c-s 0.5Sq.mm Multi Strand 10 Core
50
-
-
For establishing SCADA Communication Cables-Supplying and Laying-Current Cables-Copper Core with c-s 1.5 Sq.mm Multi Strand 10 Core
50
-
-
For establishing SCADA Communication Cables-Supplying and Laying- One number with 8 Output points for 110kV Optocoupler mounted within the RTU panel for indication(as per market value)
1
-
-
For establishing SCADA Communication Cables-Supplying and Laying- RJ-485 cable for energy meter integration (between C&R panel to RTU panel)(as per market value)
5
-
-
For establishing SCADA Communication Cables-Supplying and Laying- MFT for 110kV line bay(as per market value)
1
-
-
For establishing SCADA Communication Cables-Supplying and Laying-Terminal Blocks(Knife Type)
60
-
-
Rubber Mats 2000mm x 1000mm x 12mm size suitable for 1.1kV Class
1
-
-
Equipments name plates and earthing name plates including fixing at out yard
6
-
-
Tower accessories-Circuit plate
7
-
-
Tower accessories-Phase plate (Set of 3 No.)
7
-
-
ACSR Lynx Conductor Plain Terrian
4.93
-
-
Earth wire -7-3.15mm Ground wire Plain Terrian
0.03
-
-
FOR LINE-CIRCUIT BREAKER-SF-6 Gas circuit breaker with semi-pneumatic - pneumatic operated - spring type operating mechanism including mounting arrangements R bi-metallic terminal connector complete suitable for Drake ACSR and mounting structures. 110 kV, 1250 A, 31.5 KA SF6 CB
1
-
-
ISOLATORS-110 kV, 1250 A, 40 KA class double break manually operated isolator with solid core insulators Upright mounting type with Earth switch.LPH 4600mm
1
-
-
ISOLATORS-110 kV, 1250 A, 40 KA class double break manually operated isolator with solid core insulatorsUpright mounting type without Earth switch.LPH 4600mm
1
-
-
CURRENT TRANSFORMER-Current transformer Single phase, oil filled outdoor type with R bimetallic terminal connectors suitable for drake ACSR-110 kV class, 31.5 KA, CT of ratio 400 - 200- 1-1-1A For metering- Accuracy 0.2s, Burden 10 VA
For backup protection- Accuracy 5P20. Burden 30 VA
For differential -Distance protection PS class (for LINES)
3
-
-
SURGE ARRESTOR (Procelain housing) metal oxide, Gapless type with R bimetallic connectors suitable for drake ACSR.96 kV, 10 KA, class - II, Heavy duty Metal oxide type
3
-
-
Control and Relay Panel complete Simplex-110kV Line Panel
1
-
-
STATION STRUCTURES-110 kV Station Structure fabricated out of galvanised iron. Column type 1T1 with peak. (0.956 MT per tower)
0.96
-
-
STATION STRUCTURES-110 kV Station Structure fabricated out of galvanised iron. Beam type 1B1(0.504 MT per tower)
0.5
-
-
MOUNTING STRUCTURES-110 kV Isolators. (0.76 MT per Structure)
1.52
-
-
MOUNTING STRUCTURES-Current transformer. 110 kV CT & 33kV NCT's, 11 kV NCT's.(0.1490 MT per Structure)
0.45
-
-
MOUNTING STRUCTURES-Lightening arrestors. 110 kV . (0.072 MT per Structure)
0.22
-
-
MOUNTING STRUCTURES-Pedestal insulators. 110 kV(0.147 MT per Structure)
0.15
-
-
Drake ACSR FOR BUS BAR FORMATION
100
-
-
7-3.15 mm Ground wire FOR BUS BAR FORMATION
50
-
-
Formation of Main-Cross bus on 110kV side with single Drake FOR BUS BAR FORMATION per bay
1
-
-
Faraday Cage formation as per specification for 110kV FOR BUS BAR FORMATION per bay
1
-
-
Post insulator Solid core Insulator 110 kV
1
-
-
PVC insulated Copper Control Cable with Lugs - Ferrules. 1.1 KV class. Size of cable 19 Core 2.5 Sq.mm. Copper Control Cables
300
-
-
PVC insulated Copper Control Cable with Lugs - Ferrules. 1.1 KV class. Size of cable 2 Core 2.5 Sq.mm. Copper Control Cables
500
-
-
PVC insulated Copper Control Cable with Lugs - Ferrules. 1.1 KV class. Size of cable 4 Core 6.0 Sq.mm. Copper Control Cables
500
-
-
PVC insulated Copper Control Cable with Lugs - Ferrules. 1.1 KV class. Size of cable 4 Core 4.0 Sq.mm. Copper Control Cables
250
-
-
PVC insulated Copper Control Cable with Lugs - Ferrules. 1.1 KV class. Size of cable 4 Core 2.5 Sq.mm. Copper Control Cables
600
-
-
For establishing SCADA Communication Cables-Supplying and Laying-Current Cables-Copper Core with c-s 4.0Sq.mm Multi Strand 7 Core
50
-
-
For establishing SCADA Communication Cables-Supplying and Laying-Current Cables-Copper Core with c-s 2.5Sq.mm Multi Strand 4 Core
50
-
-
For establishing SCADA Communication Cables-Supplying and Laying-Current Cables-armoured Copper Core with c-s 0.5Sq.mm Multi Strand 10 Core
50
-
-
For establishing SCADA Communication Cables-Supplying and Laying-Current Cables-Copper Core with c-s 1.5 Sq.mm Multi Strand 10 Core
50
-
-
For establishing SCADA Communication Cables-Supplying and Laying- One number with 8 Output points for 110kV Optocoupler mounted within the RTU panel for indication(as per market value)
1
-
-
For establishing SCADA Communication Cables-Supplying and Laying- RJ-485 cable for energy meter integration (between C&R panel to RTU panel)(as per market value)
5
-
-
Earth Mat formation-Grounding of equipments with 50 x 6 mm G I flat and connecting equipments to the earth mat-ground pit including all connected works with all materials supplied by the contractor.
275
-
-
Excavation, formation, refilling for earth mat
54
-
-
Providing C.I. Pipe of 100mm ID 13mm thick 2.75 mtr. long with 2 part GI Flat 50x6mm clamp welded allround the pipe etc., including cost of excavation (all materials supplied by contractor)
3
-
-
Supplying and fixing 450mm dia x 450mm height 1.5Inch to 2Inch Hume pipe collars for earth pits.
3
-
-
FOR LINE-CIRCUIT BREAKER-SF-6 Gas circuit breaker with semi-pneumatic - pneumatic operated - spring type operating mechanism including mounting arrangements R bi-metallic terminal connector complete suitable for Drake ACSR and mounting structures. 110 kV, 1250 A, 31.5 KA SF6 CB
1
-
-
ISOLATORS-110 kV, 1250 A, 40 KA class double break manually operated isolator with solid core insulators Upright mounting type with Earth switch.LPH 4600mm
1
-
-
ISOLATORS-110 kV, 1250 A, 40 KA class double break manually operated isolator with solid core insulatorsUpright mounting type without Earth switch.LPH 4600mm
1
-
-
CURRENT TRANSFORMER-Current transformer Single phase, oil filled outdoor type with R bimetallic terminal connectors suitable for drake ACSR-110 kV class, 31.5 KA, CT of ratio 400 - 200- 1-1-1A For metering- Accuracy 0.2s, Burden 10 VA
For backup protection- Accuracy 5P20. Burden 30 VA
For differential -Distance protection PS class (for LINES)
3
-
-
Control and Relay Panel complete Simplex-110kV Line Panel
1
-
-
110 kV Station Structure fabricated out of galvanised iron. Column type 1T1 with peak. 0.956 MT per tower)
1
-
-
Foundation-
Engineering supplyof all labours, materials and construction of RCC Footings of any depth, pedestals including the cost of Excavation, Concreting, Cement, Reinforcement steel for all the works, Grouting, under pinning etc., for the following station towers and mounitng structures. for 110kV, 1250A, 40KA, SF6, CB
1
-
-
Foundation-
Engineering supplyof all labours, materials and construction of RCC Footings of any depth, pedestals including the cost of Excavation, Concreting, Cement, Reinforcement steel for all the works, Grouting, under pinning etc., for the following station towers and mounitng structures. for 110 kV Isolators. (0.760 MT per Structure)
2
-
-
Foundation-
Engineering supplyof all labours, materials and construction of RCC Footings of any depth, pedestals including the cost of Excavation, Concreting, Cement, Reinforcement steel for all the works, Grouting, under pinning etc., for the following station towers and mounitng structures. for Current transformer. 110 kV CT & 11 kV NCT's.(0.149 MT per Structure)
3
-
-
Foundation-
Engineering supplyof all labours, materials and construction of RCC Footings of any depth, pedestals including the cost of Excavation, Concreting, Cement, Reinforcement steel for all the works, Grouting, under pinning etc., for the following station towers and mounitng structures. For Lightening arrestors. 110 kV . (0.1400 MT per Structure)
3
-
-
Foundation-
Engineering supplyof all labours, materials and construction of RCC Footings of any depth, pedestals including the cost of Excavation, Concreting, Cement, Reinforcement steel for all the works, Grouting, under pinning etc., for the following station towers and mounitng structures. For Pedestal insulators. 110 kV . (0.1500 MT per Structure)
1
-
-
Jelly spreading-
Providing and spreading 20-25 mm jelly in station yard including conveying, stacking for measurement, spreading in layer of 100 mm over all.
300
-
-
Cable ducts - Construction of RCC Main Cable duct with 2 nos of NP2 Pipe with internal dimension 450 x 450 mm as per Technical specification design and drawings. including material, cement, steel, flats.
25
-
-
Cable ducts - Construction of RCC Main Cable duct with 1 nos of NP2 Pipe with internal dimension 450 x 450 mm as per Technical specification design and drawings. including material, cement, steel, flats.
50
-
-
Inspection Chambers Construction of Brick masonary inspection chamber with cast iron cover of size 600 x 450 mm as per technical specification design and drawing
5
-
-
Inspection Chambers- Providing Inspection Chambers of Size 450x450mm with Cast iron Covers as per specification
5
-
-