Karnataka Power Transmission Corporation Limited Tender
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
Costs
EMD
₹ 33,900Document Cost
Refer DocumentsTender Fee
₹ 850
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
KPTCL/2024-25/BD/WORK_INDENT1045/CALL-2Tender No
KPTCL/2024-25/BD/WORK_INDENT1045/CALL-2Tender Authority
Karnataka Power Transmission Corporation Limited ViewPurchaser Address
-Website
http://http://www.kptcl.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
code04 - Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (SR 2023-24, I-2.2.1 VP -15 Vol-I) FOr Footing
31
6993
216803.15
code05 - Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (SR 2023-24, I-2.2.1 VP -15 Vol-I) For Column
11
11008
121093.83
code06 - Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (SR 2023-24, I-2.2.1 VP -15 Vol-I) For Plinth beam and slab
42
9713
407963.22
code07 - Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (SR 2023-24, I-2.2.1 VP -15 Vol-I) FOr Roof Beam , Lintel
12
10360
124331.64
code08 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.
) (SR 2023-24 I-2.11h VP -18 Vol-I)
7.5
81371
610282.725
code09 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.n. (I-6.32 VP-17)SR 2023-24Vol-1
250
1349
337325
code10 - Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.( SR 2023-24 Vol-II, I-8.3.1 VP-41)
680
364
247941.6
code11 - Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm (SR 2023-24 V-2 VP-60 I-9.12.2)
150
1179
176902.5
code12 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. (SR 2023-24 V-2 VP-60 I-9.9)
120
1108
132993.6
code13 - Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications. (SR 2023-24 V-2 VP-87 I-11.35.1.1)
400
465
186220
code14 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding (SR 2023-24 V-2 VP-86 I-11.34A)
570
173
98632.8
code15 - Solid core board flush doors 40 mm thick one side teak and one side commercial (SR 2023-24 V-2 VP-786 I-A36)
11.6
2739
31781.68
code16 - Providing Honne wood wrought and putup for purlins, common rafters and similar work including cost of materials, labour, usage charges complete
as per specifications.(SR 2023-24 V-2 VP-99 I-12.2)
0.23
140358
32282.34
code17 - Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer (SR 2023-24 VP 132 I-14.7.3 Vol-2 )
3
2591
7775.94
code18 - Providing & fixing White vitreous china water closet squatting pan (Indian type) along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. Orissa pattern W.C Pan of size 580x440 mm (SR 2023-24 VP 202 I-20.44.2 Vol-2 )
1
3653
3653.41
code19 - Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid (SR 2023-24 VP 132 I-14.2.1 Vol-2 )
2
4983
9966.28
code20 - Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.(SR 2023-24 VP 136 I-14.31 Vol-2 )
3
1366
4099.2
code21 - Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
SR 2023-24 VP 77 I-11.3 Vol-2 )
5.76
1256
7238.016
code22 - Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (SR 2023-24 VP 84 I-11.26.3 Vol-2 )
200
188
37698
code23 - Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.
(SR 2023-24 VP 63 I-9.24 Vol-2 )
10
2937
29375.6
code24 - Designing, fabricating, testing, protection, installing and fixing in position
semi (grid) unitized system of structural glazing (with open joints) for
linear as well as curvilinear portions of the building for all heights and
all levels, including:(a) Structural analysis & design and preparation of
shop drawings for the specified design loads conforming to IS 875 part III
(the system must passed the proof test at 1.5 times design wind pressure
without any failure), including functional design of the aluminum sections
for fixing glazing panels of various thicknesses, aluminium cleats, sleeves
and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc.,
structural and weather silicone sealants, flashings, fire stop (barrier)-cumsmoke seals, microwave cured EPDM gaskets for water tightness, pressure
equalisation & drainage and protection against fire hazard including:(b)
Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium
alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to
accommodate 3 Dimentional movement for achieving perfect verticality
and fixing structural glazing system rigidly to the RCC/ masonry/
structural steel framework of building structure using stainless steel
anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts
with nuts and washers etc. of stainless steel grade 316, of the required
capacity and in required numbers.(c)Providing and filling, two part pump
filled, structural silicone sealant and one part weather silicone sealant
compatible with the structural silicone sealant of required bite size in a
clean and controlled factory / work shop environment, including double
sided spacer tape, setting blocks and backer rod, all of approved grade,
brand and manufacture, as per the approved sealant design, within and all
around the perimeter for holding glass.(d)Providing and fixing in position
flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and
profiles, as required as per the site conditions, to seal the gap between
the building structure and all its interfaces with curtain glazing to make
it watertight.(e) Making provision for drainage of moisture/ water that
enters the curtain glazing system to make it watertight, by incorporating
principles of pressure equalization, providing suitable gutter profiles at
bottom (if required), making necessary holes of required sizes and of
required numbers etc. complete.
10
2765
27655.5
code25 - Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete For Straight Portion (SR 2023-24 V-3 VP-71 I-10.15.1)
12
4467
53612.16
code26 - Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SR-2023-24 V-II VP-46 I-8.32
400
160
64272
code27 - Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.SR-2023-24 V-II VP-46 I-8.33.1
300
91
27501
code28 - ELECTRIFICATION
Supplying 2mm thick 20mm dia pvc conduict with required accessories before casting roof/column and fixing on wall after grove cutting and wiring using copper wire and required materials for laying of conduict and includes screws, bends, deep junction boxe Short point (Up to 3 Mtrs) SR2023-24 nVP 5 I- 2.1.1
5
269
1345
code29 - A) Medium point (3mtrs to 6 Mtrs) SR2023-24 nVP 5 I- 2.1.1
5
378
1894.95
code30 - C) Long point ( From 6 mts to 10 Mtr) SR 2023-24 vol-6 VP-2 I- 2.1.1
4
555
2220
code31 - Supplying 6 amps 3/5 way flush / projected by socket and 5 amps flush type SP, switch either surface mounted on a gang box or in a 4mm thick plastic sheet and fixing over a flash mounted on TW box and wiring using necessary wire SR 2023-24 vol-6 VP-5 I- 3.1.2
4
146
587.96
code32 - Supplying and fixing 32Amps security and energy saving DP switch with key tag suitable to operate on 230 Volts, 50Hz AC supply & completely wired on existing box. SR 2023-24 vol-6 VP 6 I- 3.7
3
646
1938
code33 - Supplying and fixing teak wood board with out front plank made out of not 15mm thick planks with planks made out of not more than two pieces and fixing the same to the wall using tappered inverted teak wood plugs screwed etc ,A. 254x178x76mm (10'x7'x3) SR 2023-24 vol-6 VP 05 I-1.6.3
2
111
223.98
code34 - 32 Amps Bakelite DP SR 2023-24 vol-6 VP - 06 I- 3.14.13
2
231
463.98
code35 - Supplying and drawing PVC insulated flexible copper wire of approved make.A.40/0.0040'' copper wire SR 2023-24 vol-6 VP - 6 I- 2.4.3
70
28
2029.3
code36 - B. 70/0.0052 copper wire. SR 2023-24 vol-6 VP - 6 I- 2.4.8
50
30
1500
code37 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. SR 2023-24 vol-6 VP - 3 I- 2.3.6
50
167
8350
code38 - Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia SR 2023-24 vol-6 VP - 40 I- 6.1
2
2999
5999.4
code39 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve , indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 Amps SP.SR 2023-24 vol-6 I. No. 5.18.4, Pg No. 13
2
739
1478
code40 - Supplying of recess mounting non integrated type LED down light ...... W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartmentis enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit,THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. SR 2023-24 vol-6 VP 34 I 11.4.2
6
1269
7614
code41 - Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment, Rated voltage 220 V/ 50 Hz, Rated power input 48 W 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 10% Cubic Meter Minimum, Rated service value 4.2 CMM / Watt, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201 , as per IS specification, Motor wdg. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 Volts, Insulation resistance Shall not be less than Two Mega Ohms (2 M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, watt& current , Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty. 48" Sweep 5 Star (1200mm)SR 2023-24 vol-6 I- 6.4.1 VP 23
3
2949
8847
code42 - Fixingaceiling/wallmountingfanofallcapacitiesandalltypes,withnecessaryclampsand'S'hookmadeoutof15mmdiaMSrod,with5A.ceilingroseofapprovedqualitywithnecessarylengthof23/0.0076inchPVCinsulatedtwintwistedwireofapprovedquality,mounted on a suitable size wooden board and wired..SR 2023-24 vol-6 I- 13.11 VP 46
3
315
945
code43 - Supplying exhaust fan with bracket blades complete for LIGHT DUTY of approved make crompton / almonard of size 457mm or (18") 900 RPM. SR 2023-24 vol-6 VP-22 I-6.1
2
1492
2984
code44 - Fixing one exhaust fan after making a suitable hole in the wall finishing with CM and welding to existing wall or brackets with bolts and nuts and 5amps ceiling rose with sufficient length of 23/0.0076" PVC insulated twin core wire of approved make. SR 2023-24 vol-6 VP 46 I-13.13
2
707
1414
code45 - Supplying ......TR split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacitors, relay and over load protector internal unit, with one indoor and one outdoor unit The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube. (High wall chorded/cordless) suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit 1.5 Ton capacity SR 2023-24 Vol-6 I- 6.7.2 VP-31
1
47683
47683
code46 - Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C. SR 2023-24 Vol-6 I- 6.12 VP-31
1
3175
3175
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%