Karnataka Power Corporation Limited Tender

... More
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Karnataka Power Corporation Limited - KPCL Tender

Works
Electrical Goods and Equipments
Electrical and Electronics
Opening Date8 Mar 2025
Closing Soon16 Mar 2025
Tender Amount₹ 9,22,414.06 
Notes
Download

Costs

Summary

Providing Power Supply And Electrification To Renovated Store At Yccp Plant, Yelahanka

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
004 - Supplying wall mounting fan suitable to operate at single- phase 230v AC. Supply - 400 mm Sweep

3

3790

11370.48

... More
005 - Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired

3

371

1115.1

... More
006 - Supply of 70 W LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate,clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70 percentage. Surge Protection Min 5KV along with Over voltage Overload, short circuit, miss wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50 60Hz application. Compliance to IS 10322 IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. Luminaire manufacturer should have in house facility accredited by NABL CPRI & any Government certified agency & Design & Development facility certified by ISO 9001 2008. Housing with supplier word mark, name shall be Engraved, Embossing on the die cast housing, Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer

4

7986

31944.96

... More
007 - Supply of 100 W LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate,clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70 percentage. Surge Protection Min 5KV along with Over voltage Overload, short circuit, miss wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50 60Hz application. Compliance to IS 10322 IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. Luminaire manufacturer should have in house facility accredited by NABL CPRI & any Government certified agency & Design & Development facility certified by ISO 9001 2008. Housing with supplier word mark, name shall be Engraved, Embossing on the die cast housing, Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer

16

11193

179095.68

... More
008 - Fixing charges of post top/ Gate/ Garden fitting /LED on the existing CI/ GI or any other pipe using required size of reducer, wiring using suitable wires

20

233

4672.8

... More
009 - Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.

80

571

45689.6

... More
010 - supply of Brick - Table Moulded Bricks

400

10

4152

... More
011 - Supplying and filling in plinth, foundations / UG cable work with approved M-sand including watering, ramming, consolidating and dressing. The rate includes the cost of material, labour charges, required tools and plants etc., complete. Work shall be carried out as per the instructions of Engineer- in-charge of works as per the standard procedure

7.2

1044

7518.96

... More
012 - Supply of 35 Sqmm, 3.5 Core, (14 GI Strips - 4 x 0.8 mm) 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975

0.2

181793

36358.64

... More
013 - Laying of 35 sqmm cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff

0.02

36744

734.8804

... More
014 - Supplying of 32 sqmm Aluminium End Terminal (Lug) lugs and crimping and wiring to terminal point

8

4

37.76

... More
015 - Supplying of 16sq mm Aluminium End Terminal (Lug) lugs and crimping and wiring to terminal point

30

2

70.8

... More
016 - Supplying and fixing regular 4 Way MCCB distribution Panel confirmingto IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2

1

12188

12188.22

... More
017 - Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board - 63 A 4 poleq

1

6543

6543.1

... More
018 - Wiring for lighting/power circuit using 2.5 mm2 of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010

1250

49

61950

... More
019 - Wiring for lighting/power circuit using 4 sqmm of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:20104

1950

74

144963

... More
020 - Wiring for lighting/power circuit using of 10 sqmm FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:201010

100

197

19706

... More
021 - Wiring for lighting/power circuit using 16 sqmm of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010

100

375

37524

... More
022 - Supplying and fixing 12 Way SP & N regular MCB distribution boards on wall/oodboard / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3phase/single door with powder coated painting Made out of 14 SWG MS enclosure

3

2198

6595.02

... More
023 - Supplying & fixing 6-32 A SP miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898

25

489

12242.5

... More
024 - Supplying & fixing 6-32 A DP miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898

10

872

8720.2

... More
025 - Supplying & fixing 40 A TPN miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898

4

3591

14367.68

... More
026 - Supplying & fixing 50-63 A TPN miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898

1

3643

3643.84

... More
027 - Supplying and fixing of 6A One Way Switch on existing modular switch plate as per IS 3854 and IS 1293

25

120

3009

... More
028 - Supplying and fixing of 6A Three Way socket on existing modular switch plate as per IS 3854 and IS 1293

7

201

1412.46

... More
029 - supplying and fixing of Stepped Fan Regulator Two Module on existing modular switch plate as per IS 3854 and IS 1293

2

421

842.52

... More
030 - Supplying and fixing of 16A One Way Switch on existing modular switch plate as per IS 3854 and IS 1293

8

212

1699.2

... More
031 - Supplying and fixing of 32A DP Switch on existing modular switch plate as per IS 3854 and IS 1293

8

384

3077.44

... More
032 - Supplying and fixing of 6/16A Universal Socket on existing modular switch plate as per IS 3854 and IS 1293

8

278

2227.84

... More
033 - Supplying and flush mounting powder coated / galvanized metal box of 4-5 Way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall

7

208

1462.02

... More
034 - Supplying and flush mounting powder coated / galvanized metal box of 6 Way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall

7

259

1817.2

... More
035 - Supplying and flush mounting powder coated / galvanized metal box of 8 Way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall

5

307

1539.9

... More
036 - Supplying and fixing superior quality 4 Module modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box

7

206

1445.5

... More
037 - Supplying and fixing superior quality 6 Module modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box

7

276

1932.84

... More
038 - Supplying and fixing superior quality 8 Module modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box

5

335

1675.6

... More
039 - Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified

2

2562

5125.92

... More
040 - Supplying heavy gauge PVC conduit pipe 25 mm dia 2 mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws

900

95

86022

... More
041 - Supplying heavy gauge PVC conduit pipe19/20 mm dia 2 mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.

1100

81

89562

... More
042 - Supplying of LED light fitting 1 x 4' - 36/40 W feet -PVC Batten with integrated LED tube with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220- 240V 50/60Hz & Power factor higher than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition

8

814

6513.6



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.