Karnataka Neeravari Nigam Limited Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Karnataka Neeravari Nigam Limited - KNNL Tender

Works
Civil And Construction
Building Construction
Opening Date24 Dec 2024
Closing Soon2 Jan 2025
Tender Amount₹ 57,26,189.57 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per specifications as directed by Engineer-in-Charge.

169

596

100791.6

... More
code05 - Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete as per specifications as directed by Engineer-in-Charge.

84

308

25930.8

... More
code06 - Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20mm thickness and of approved pattern on steel frame work complete as per specifications as directed by Engineer-in-Charge..

21

68

1433.25

... More
code07 - Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. (0.63 mm thick with zinc coating not less than 275 g/m²) as per specifications as directed by Engineer-in-Charge.

42

677

28444.5

... More
code08 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates as per specifications as directed by Engineer-in-Charge.

0.659

6961

4587.6285

... More
code09 - Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work as per specifications as directed by Engineer-in-Charge.

1.38

8367

11547.081

... More
code10 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Building as per specifications as directed by Engineer-in-Charge.

0.026

93929

2442.1761

... More
code11 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge

34

389

13244.7

... More
code12 - Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge

34

182

6211.8

... More
code13 - Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge

93.45

145

13639.0275

... More
code14 - Providing & supplying Carpet/Mat of 800+ gsm with stain proof, flexible and super absorbent fibre of good quality as per direction of Engineer -in-charge

71.393

1470

104947.71

... More
code15 - Providing and supplying 19mm thick both side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand boxes, shelves, racks, almirah, cupboard and drawer etc., including necessary nails, screws etc., complete as per direction of Engineer-in-charge

195.58

1165

227948.49

... More
code16 - Labour & installation charges for BWP ply:BWR ply:HDHMR:MDF & Particle board work of any thickness applicable for all types of work complete as per specifications and as per directions of Engineer-in-charge

195.58

2100

410718

... More
code17 - Providing and fixing good quality Exterior grade High Pressure Laminate (Single sided Thermosetting synthetic resin bonded sheet-Craft Paper Base) of 6mm thick as per IS 2046 standard with colors as per Architect choice (Brown red, Suede, Sandblast, brown, Matte, Wooden or similar colors) for cladding including fixing with necessaryAluminium frames, fixtures complete as per specifications and as per directions of Engineer-in-charge

195.58

4231

827596.77

... More
code18 - Providing and fixing in position fully glazed windows shutters with Teak wood styles and rails of 35mm. thick 75mm wide in single shutters with 4mm thick plain glass fixed with wooden beading including cost of materials, labour charges, usage charges complete as per specifications. (excluding cost of fixtures) complete as per specifications and as per directions of Engineer-in-charge

30.42

11322

344419.803

... More
code19 - Providing Mathi / Nandi wood wrought and putup for purlins, common rafters and similar work including cost of materials, labour, usage charges complete as per specifications and as per directions of Engineer-in-charge

0.82

128518

105385.539

... More
code20 - Providing and fixing powder coated telescopic drawer channels 300 mm long with necessary screws etc., complete as per specifications and as per directions of Engineer-in-charge

7

434

3042.9

... More
code21 - Providing & fixing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame. Flat surfaces etc., complete as per specifications and as per directions of Engineer-in-charge

89.24

1337

119376.348

... More
code22 - Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge

67.21

141

9527.0175

... More
code23 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge

26.15

105

2745.75

... More
code24 - Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade:New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt,dust,mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour etc., complete as per specifications and as per directions of Engineer-in-charge

26.15

143

3761.6775

... More
code25 - High back chair with seat and back high quality feather touch rexine arms with chushing chair to have 5 caster wheel legs along with synchromechanism KSFIC-TF 124 etc., complete as per specifications and as per directions of Engineer-in-charge

12

17980

215760

... More
code26 - High back chair with seat and back high quality feather touch rexine arms with chushing chair to save SS with 5 caster wheel legs along with synchromechanismKSFIC-TF 123 etc., complete as per specifications and as per directions of Engineer-in-charge

20

12600

252000

... More
code27 - P.A.System amplifier 250WRMS output with complete wiring and controls accessable form front etc., complete as per specifications and as per directions of Engineer-in-charge

1

35250

35250

... More
code28 - Supplying Installing, testing and commissioning of MIKE suitable toI.A.System. Complete etc., complete as per specifications and as per directions of Engineer-in-charge

11

5500

60500

... More
code29 - Supply, installation, testing and commissioning of Addressable Wireless Conventional Wall Sound erwith Beacon for providing Audible and Visual Alarm sinresponseto the output signal from the control panel, 32selectable tone and adjustable sound level,maximum output volume@1Mdistance100dB(A),output tone frequency range 440Hzto2900Hz, Visual alarm device output requency 0.5Hz,Approved byLPCB for EN54-3 standard with Intelligent Sounder Interface Moduleradio-linked. Radio transmission of150m(infreeair),operating at de-licensed frequency range of 865MHz all as specified and directed Approval by IMQ for EN54-7 & EN54-25 etc., complete as per specifications and as per directions of Engineer-in-charge.

4

14000

56000

... More
code30 - Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rub bing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent etc., complete as per specifications and as per directions of Engineer-in-charge.

1.8

2589

4660.74

... More
code31 - Providing & fixing Roller blinds of reputed make 38mm round Aluminium channel with blackout fabric, telting with chain (Ball) system with all necessary fittings and fixtures etc., complete as per specifications and as per directions of Engineer-in-charge

11.32

1890

21394.8

... More
code32 - Intel core i5 all in one PC with 23.8 inch display/DOS etc., complete as per specifications and as per directions of Engineer-in-charge

1

60614

60614

... More
code33 - Multifunction machines mfm,on site OEM warranty 5 year etc., complete as per specifications and as per directions of Engineer-in-charge

1

21100

21100

... More
code34 - Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other ppurtenances required to complete the work as per technical specifications etc., complete as per specifications and as per directions of Engineer-in-charge

36.336

6724

244330.5312

... More
code35 - Providing and laying water proofing treatment to the Roof with PU based single component elastomeric cold applied PU tensile strength ats @ 1.6 kg/m2 @150 g/m2 and o include surface ompletely as per pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, wa terproofing membrane that is highly elastic with elongation greater than 400% and greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2co to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer protection with 120gsm Geo-textile over the wa terproofing membrane. The finished cost t preparation, making coving at Junction, Bore Packing, treatment of construction joints c specification etc., complete as per specifications and as per directions of Engineer-in-charge.

363.2

857

311571.12

... More
code36 - Dismantling alluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal area as disposal of unserviceable material and stacking of serviceable material to the appropriate per direction of Engineer-in-charge.

314.18

37

11876.004

... More
code37 - Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 g/m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, madeof Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit. (PWD CSR V-2 2023-24 / P.No. 27 I.No.7.40.3)

314.18

2076

652520.442

... More
code38 - Supplying of recess mounting non integrated type LED down light...... W luminaire comprising of pressure dycast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a

39

1269

49491

... More
code39 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS

14

166

2324

... More
code40 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.1 to 2 Module (PWD Electrical SR V-6 2023-24 / P.No. 8 I.No.3.5.1)

5

137

685

... More
code41 - Supplying of recess mounting non integrated type LED down light...... W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition etc., complete as per specifications and as per directions of Engineer-in-charge for 24 W.

20

1733

34660

... More
code42 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 1 sqmm etc., complete as per specifications and as per directions of Engineer-in-charge. 1 sqmm

130

19

2470

... More
code43 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments etc., complete as per specifications and as per directions of Engineer-in-charge. 1.5 sqmm

150

26

3900

... More
code44 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments etc., complete as per specifications and as per directions of Engineer-in-charge. 2.5 sqmm

100

42

4200

... More
code45 - Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 14.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests etc., complete as per specifications and as per directions of Engineer-in-charge .

1

5128

5128.2

... More
code46 - Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life)

809.28

165

134259.552

... More
code47 - Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary etc., complete as per specifications and as per directions of Engineer-in-charge. 19/20 mm dia 2 mm thick

150

66

9900

... More
code48 - Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary etc., complete as per specifications and as per directions of Engineer-in-charge. 25 mm dia 2 mm thick

90

78

7020

... More
code49 - Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary etc., complete as per specifications and as per directions of Engineer-in-charge. 19/20 mm dia 2 mm thick

50

68

3400

... More
code50 - Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary etc., complete as per specifications and as per directions of Engineer-in-charge. 25 mm dia 2 mm thick

90

79

7110

... More
code51 - Supplying And Fixing Metal Fan Box with Round Hook etc.,complete as per specifications and as per directions of Engineer-in-charge.

6

117

702

... More
code52 - Point wiring using Copper wire without switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet etc.,complete as per specifications and as per directions of Engineer-in-charge. Short point upto 3Mtr from tapping point to out let via switch box

4

269

1076

... More
code53 - Point wiring using Copper wire without switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet etc.,complete as per specifications and as per directions of Engineer-in-charge. Short point upto 3Mtr from tapping point to out let via switch box etc.,complete as per specifications and as per directions of Engineer-in-charge. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box

3

379

1137

... More
code54 - Point wiring using Copper wire without switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet etc.,complete as per specifications and as per directions of Engineer-in-charge. Short point upto 3Mtr from tapping point to out let via switch box etc.,complete as per specifications and as per directions of Engineer-in-charge.Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box

17

555

9435

... More
code55 - Point wiring using Copper wire without switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet etc.,complete as per specifications and as per directions of Engineer-in-charge. Short point upto 3Mtr from tapping point to out let via switch box etc.,complete as per specifications and as per directions of Engineer-in-charge.Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to out let via switches

40

677

27080

... More
code56 - Point wiring using Copper wire without switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet etc.,complete as per specifications and as per directions of Engineer-in-charge. Short point upto 3Mtr from tapping point to out let via switch box etc.,complete as per specifications and as per directions of Engineer-in-charge. Three outlet in a row, above 6Mts upto 10Mtr from tapping point to out let via switches box

20

989

19780

... More
code57 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 etc.,complete as per specifications and as per directions of Engineer-in-charge. 1.5 sqmm

375

26

9750

... More
code58 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 etc.,complete as per specifications and as per directions of Engineer-in-charge. 2.5 sqmm

350

42

14700

... More
code59 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 etc.,complete as per specifications and as per directions of Engineer-in-charge. 4 sqmm

400

63

25200

... More
code60 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 etc.,complete as per specifications and as per directions of Engineer-in-charge. 6 sqmm

200

92

18400

... More
code61 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall etc.,complete as per specifications and as per directions of Engineer-in-charge. 3 Way

8

159

1272

... More
code62 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall etc.,complete as per specifications and as per directions of Engineer-in-charge. 4-5 Way

2

177

354

... More
code63 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall etc.,complete as per specifications and as per directions of Engineer-in-charge.6 Way

6

220

1320

... More
code64 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall etc.,complete as per specifications and as per directions of Engineer-in-charge. 8 Way

2

261

522

... More
code65 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall etc.,complete as per specifications and as per directions of Engineer-in-charge. 10-12 Way

8

319

2552

... More
code66 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box etc.,complete as per specifications and as per directions of Engineer-in-charge. 3 Module

8

161

1288

... More
code67 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box etc.,complete as per specifications and as per directions of Engineer-in-charge. 4 Module

2

175

350

... More
code68 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box etc.,complete as per specifications and as per directions of Engineer-in-charge.6 Module

6

234

1404

... More
code69 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box etc.,complete as per specifications and as per directions of Engineer-in-charge.8 Module

2

284

568

... More
code70 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box etc.,complete as per specifications and as per directions of Engineer-in-charge.10-12 Module

8

344

2752

... More
code71 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 etc.,complete as per specifications and as per directions of Engineer-in-charge. 6A One Way Switch

107

102

10914

... More
code72 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 etc.,complete as per specifications and as per directions of Engineer-in-charge. 6A Two Way Switch

2

166

332

... More
code73 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 etc.,complete as per specifications and as per directions of Engineer-in-charge. 6A Three Way socket

23

171

3933

... More
code74 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 etc.,complete as per specifications and as per directions of Engineer-in-charge. Stepped Fan Regulator Two Module

5

357

1785

... More
code75 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 etc.,complete as per specifications and as per directions of Engineer-in-charge. 16A One Way Switch

5

180

900

... More
code76 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 etc.,complete as per specifications and as per directions of Engineer-in-charge. 6/16A Universal Socket

5

236

1180

... More
code77 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 etc.,complete as per specifications and as per directions of Engineer-in-charge. 6A Bell Push

1

177

177

... More
code78 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 etc.,complete as per specifications and as per directions of Engineer-in-charge.32A DP Switch

5

326

1630

... More
code79 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 etc.,complete as per specifications and as per directions of Engineer-in-charge.TV/Telephone Socket

2

156

312

... More
code80 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 etc.,complete as per specifications and as per directions of Engineer-in-charge.TV/Telephone Socket RJ45/I.O Outlet Cat-6

2

337

674

... More
code81 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898, etc.,complete as per specifications and as per directions of Engineer-in-charge.6-32 A SP

22

415

9130

... More
code82 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898, etc.,complete as per specifications and as per directions of Engineer-in-charge 6-32 A DP.

2

739

1478

... More
code83 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898, etc.,complete as per specifications and as per directions of Engineer-in-charge 50-63 A TPN .

1

3088

3088

... More
code84 - Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure etc.,complete as per specifications and as per directions of Engineer-in-charge II - Double Door. 12 Way SP & N

1

2329

2329

... More
code85 - Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure etc.,complete as per specifications and as per directions of Engineer-in-charge II - Double Door.4 Way TP & N

1

4038

4038

... More
code86 - Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board etc.,complete as per specifications and as per directions of Engineer-in-charge 32-40A 2 pole

1

4559

4559

... More
code87 - Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) etc.,complete as per specifications and as per directions of Engineer-in-charge 48" Sweep 5 Star (1200 mm)

5

4303

21515

... More
code88 - Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply etc.,complete as per specifications and as per directions of Engineer-in-charge

1

1492

1492

... More
code89 - Supplying ......TR split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacitors, relay and over load protector internal unit, with one indoor and one outdoor unit The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube. (High wall chorded/cordless) suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit 5star etc.,complete as per specifications and as per directions of Engineer-in-charge 2 Ton capacity

2

54048

108096

... More
code90 - Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C etc.,complete as per specifications and as per directions of Engineer-in-charge

2

3175

6350

... More
code91 - Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tube etc.,complete as per specifications and as per directions of Engineer-in-charge Split

10

1549

15490

... More
code92 - Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries etc.,complete as per specifications and as per directions of Engineer-in-charge

2

4807

9614

... More
code93 - Supplying, erecting, testing and commissioning of voltage stabilizer suitable for 170 to 270 v input and load variation from no load to full load, with over load protection, spike suppression, operating at 00 C to 400 C. Range etc.,complete as per specifications and as per directions of Engineer-in-charge 5kVA Capacity

2

9666

19332

... More
code94 - Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition etc.,complete as per specifications and as per directions of Engineer-in-charge LED light fitting 1 x 4' - 20/22

5

690

3450

... More
code95 - Supplying of recess mounting non integrated type LED down light...... W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition etc.,complete as per specifications and as per directions of Engineer-in-charge 10-12W

88

1269

111672

... More
code96 - Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source etc.,complete as per specifications and as per directions of Engineer-in-charge LED. Floodlight 150W

4

12490

49960

... More
code97 - Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia GI/Copper strips for grounding connections, using necessary fixing materials as required etc.,complete as per specifications and as per directions of Engineer-in-charge

2

3510

7020

... More
code98 - Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia GI/Copper strips for grounding connections, using necessary fixing materials as required etc.,complete as per specifications and as per directions of Engineer-in-charge. GI/Copper strips 25 x 3 mm GI strip

40

82

3280

... More
code99 - Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps etc.,complete as per specifications and as per directions of Engineer-in-charge On wall/ ceiling / Rafter / Girders

93

122

11346

... More
code100 - Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired etc.,complete as per specifications and as per directions of Engineer-in-charge

5

315

1575

... More
code101 - Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire etc.,complete as per specifications and as per directions of Engineer-in-charge

1

492

492

... More
code102 - Supplying and Fixing of........mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires etc.,complete as per specifications and as per directions of Engineer-in-charge Using 25mm dia G.I.Pipe

6

978

5868

... More
code103 - Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires etc.,complete as per specifications and as per directions of Engineer-in-charge

21

162

3402

... More
code104 - Supply and Installation /Fixing /Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility etc.,complete as per specifications and as per directions of Engineer-in-charge 300 mm x 300 mm x 214 mm etc.,complete as per specifications and as per directions of Engineer-in-charge 300 mm x 300 mm x 214 mm

1

4512

4512

... More
code105 - Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers etc.,complete as per specifications and as per directions of Engineer-in-charge 100 A

3

691

2073

... More
code106 - Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. (Open Execution) etc.,complete as per specifications and as per directions of Engineer-in-charge 125 A

1

10326

10326

... More
code107 - Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947 etc.,complete as per specifications and as per directions of Engineer-in-charge. 40 A

1

6119

6119

... More
code108 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism etc.,complete as per specifications and as per directions of Engineer-in-charge Four pole 160 A 25 kA

1

13447

13447

... More
code109 - Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board etc.,complete as per specifications and as per directions of Engineer-in-charge

1

9255

9255

... More
code110 - Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy etc.,complete as per specifications and as per directions of Engineer-in-charge

1

9315

9315

... More
code111 - Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 A three phase 4 wire whole current class-1 Accuracy Energy Meter etc.,complete as per specifications and as per directions of Engineer-in-charge

1

5705

5705

... More
code112 - Supplying, fixing and wiring 1000/5A to 1600/5A 15VA Burden class 1 Current Transformer etc.,complete as per specifications and as per directions of Engineer-in-charge

6

840

5040

... More
code113 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C etc.,complete as per specifications and as per directions of Engineer-in-charge

6

515

3090

... More
code114 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 etc.,complete as per specifications and as per directions of Engineer-in-charge '70 Sqmm, 3.5 Core, (18 GI Strips - 4 x 0.8 mm)

0.1

317911

31791.17

... More
code115 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff etc.,complete as per specifications and as per directions of Engineer-in-charge 35 to 95 Sqmm etc.,complete as per specifications and as per directions of Engineer-in-charge

0.1

31138

3113.854

... More
code116 - Supplying and drawing UTP-CAT 6E LAN cable etc.,complete as per specifications and as per directions of Engineer-in-charge

120

38

4560

... More
code117 - Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable etc.,complete as per specifications and as per directions of Engineer-in-charge 2pair

150

21

3150

... More
code118 - Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6. etc.,complete as per specifications and as per directions of Engineer-in-charge

100

44

4400

... More
code119 - Supplying & Fixing of switch mounting rack with power manager & Cable manager etc.,complete as per specifications and as per directions of Engineer-in-charge 9U with 450mm depth

1

8476

8476

... More
code120 - Supplying fixing of Network Switches etc.,complete as per specifications and as per directions of Engineer-in-charge 16 port 10/100/1000 Switch

1

6440

6440

... More
code121 - Supplying & fixing of I/O socket with back box etc.,complete as per specifications and as per directions of Engineer-in-charge Single I/O

5

490

2450

... More
code122 - Supplying & Fixing of ... ms Cat 6 Patch Cable etc.,complete as per specifications and as per directions of Engineer-in-charge 1m.

5

224

1120

... More
code123 - Supplying, erecting, testing & commissioning of OFF- LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with all accessories complete and Excluding batteries and wiring complete etc.,complete as per specifications and as per directions of Engineer-in-charge 5 kVA OFF LINE UPS

1

39898

39898

... More
code124 - Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries etc.,complete as per specifications and as per directions of Engineer-in-charge 150 AH capacity

6

15895

95370



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.