Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
Costs
EMD
₹ 42,400Document Cost
Refer DocumentsTender Fee
₹ 530
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
KNNL/2024-25/BD/WORK_INDENT1946Tender No
KNNL/2024-25/BD/WORK_INDENT1946Tender Authority
Karnataka Neeravari Nigam Limited ViewPurchaser Address
-Website
http://http://knnlindia.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Others - MDP
Tender Document
Others - Verification of CA document
Others - Tender Notification
BOQ Items
code04 - Providing & fixing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame.(PWD CSR 2023-24 vol-2, P-24 Item No -7.28.1)
69.59
1337
93090.543
code05 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. As per PWD SR 2023-24 Vol II item no. 8.51 Page no. 50
69.59
105
7306.95
code06 - Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 g bar L as per specifications and as per directions of Engineer in charge. As per PWD SR 2023-24 Vol II item no. 8.55.2 Page no. 51
69.59
55
3872.6835
code07 - Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. As per PWD SR 2023-24 Vol II item no. 8.54.2 Page no. 50
69.59
115
8037.645
code08 - Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer Numeric Control) routed of approved design by Engineer-incharge which are machine cut for duct per shaft covering, partitions and facades comprising of virgin Polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder per rice husk per wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N per mm2 , modulus of elasticity 850 N per mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S framework required with priming coat shall be paid separately).
320.44
4631
1484133.882
code09 - Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. As per PWD SR 2023-24 Vol II item no. 11.35.1.2 Page no. 87
135
513
69315.75
code10 - Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass per stainless steel screws etc. complete as per architectural drawings and directions of engineer- in-charge: Pre-laminated particle board with decorative lamination on both sides including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. As per PWD SR 2023-24 Vol II item no. 11.36.2 Page no. 89
15.41
1032
15905.4315
code11 - Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item) to With float glass panes of 5 mm thickness (weight not less than 12.50 kg per m sqr) including cost of materials, labour, usage charges of machinery complete as per specifications. As per PWD SR 2023-24 Vol II item no. 11.37.2 Page no. 89
15.41
1229
18947.3655
code12 - Anodised Aluminium butt hinges 100x75x4 mm As per PWD SR 2023-24 Vol II item no. 47 Page no. A-13
9
41
371.34
code13 - Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. As per PWD SR 2023-24 Vol II item no. 12.60 Page no. 105
3
1104
3313.8
code14 - Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. As per PWD SR 2023 24 Vol. 2 Item no.12.59 Page no. 105
3
1169
3509.1
code15 - Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. As per PWD SR 2023 24 Vol. 2 Item no. 11.44 Page no. 91
0.9
4562
4106.025
code16 - Supplying heavy gauge PVC Conduct Pipe dia mm thick with suitable size bends, metal junction boxes adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. (Page no.2 per 105 Item no.1.3.1 of SR of PWD (Electrical) for the year 2023-24) a) 19 or 20mm dia 2mm thick
90
68
6120
code17 - Supplying and fixing PVC per metal conduit Deep junction box. (Page no.2 105 Item no.1.5.1 of SR of PWD (Electrical) for the year 2023-24) a) 19 or 20mm deep junction box
90
49
4410
code18 - Supplying and flush mounting powder coated per galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick Stone C.C wall.
10
138
1380
code19 - Extra for groove cutting in brick wall or CC floor to the suitable depth for concealing of conduit or GL pipe and plastering finishing the wall upto wall surface complete. (Page no.3 or 105 Item no.1.7.1 of f SR of PWD (Electrical) for the year 2023-24).a) upto 50mm conduit in brick wall
90
29
2610
code20 - Supplying and wiring adopting loop system in existing PVC Conduit casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. (Page no.5 Item no.2.2.1,2.2.2 ,2.2.4 of SR of PWD (Electrical) for the year 2023-24). a) Short point upto 3mtr from tapping point to out let via switch
4
269
1076
code21 - b)Medium point above 3mtr upto 6mtr from tapping point to outlet via switch
6
379
2274
code22 - C) Two outlet in a row above 3mtr upto 6mtr from tapping point to outlet via switch
6
677
4062
code23 - Wiring for lightining or power cuircuit using one of FRLS PVC insulated 1100 V grade, multistrand copper conducter single core wire in open or concealed system of wiring as per IS-694 1990 & confirming to GTP of GROUP -B. a)1.5 Sqmm
180
26
4680
code24 - b) 2.5 Sqmm
120
42
5040
code25 - c) 4 Sqmm
80
63
5040
code26 - Supplying and flush mounting powder coated galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick Stone CC wall a) 4-5 Ways
7
177
1239
code27 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal PVC box.a) 4 Module
4
175
700
code28 - b) 8 Module
4
284
1136
code29 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 a) 6 Amps one way switch
2
102
204
code30 - b) 6 Amps 3 Ways Socket
2
171
342
code31 - c) Stepped Fan Regulator
4
357
1428
code32 - d) TV Telephone Socket
2
156
312
code33 - e)16 Amps flush type universal socket -do-
25
236
5900
code34 - f)Outlet Cat-6
2
337
674
code35 - Supplying 3mm thick hylum plastic sheet with necessary nitches of fixing switches regulators etc and fixing on existing wooden or metal box using NF screws
50
-
17.5
code36 - Extra for supplying 4mm thick white plastic plate and covering for junction boxes of size mm conduit using necessary machine screws. for the year 2023-24) a) 80 per 90 mm
50
15
750
code37 - b) 110 mm
50
21
1050
code38 - Supplying and fixing/replacing of 6 or16 or 32Amps electrical accessories on existing switch board. a) 6 Amps Pendant Holder
25
71
1775
code39 - Supplying of feet -PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70 percent lumen maintenance with CRI more than 80. Power Input: 220-240V at 50 or 60Hz & Power factor more than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. a) LED light fighting 1 x4- 20 or 22 w
4
690
2760
code40 - Supplying & fixing of Porcelain fuse channel with cut out on existing wooden panel using necessary nuts, bolts and washers A)32Amps
4
241
964
code41 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, Indicator ON OFF, energy cross-3 with Short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898 a)6-32 Amps SP
3
415
1245
code42 - Supplying & fixing of retrofit type - LED bulb W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI more than 70 percent efficacy more than 80 lumen per W, life more than 25000 burning hours and Compliance to IS 10322 IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF more than 0.95, power loss should less than 5 percent of lamp Wage short circuit & open circuit protection to be integrated in the circuit, THD less than 20 percent, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL or CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.
18
426
7668
code43 - Fixing all types and all capacities of fluorescent false ceiling spot light CFL LED fittings indoor on the wall ceiling rafters girders using 23 0.0076 twin twisted PVC insulated wires, required Nos of round blocks and clamps.
18
122
2196
code44 - Fixing of amps TPST or Change over swith or contractor along with neutral link with screws,bits,nuts and wiring using required capcity wires and circuit labeling a)15A to 63A TPST(28 bar16)
4
278
1112
code45 - supplying of TPST with rewirable porelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approaved colour a) 32Amps
1
1701
1701
code46 - Supplying and fixing of Porecelain fuse channel with cut out on existing wooden panel using necessary nuts,bolts and washers a)32 Amps
1
241
241
code47 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220V AC 50 Hz 12 or 24 v DC
1
515
515
code48 - Supplying and fixing angle iron frame work fabricated out of MS angle iron and MS flat with bolts,washers etc and painted with 2 coats of red oxide and then two coats of approved paint a)40x40x6mm
4
305
1220
code49 - Fabricating supplying and mounting MS box made out SWG suitable for floor wall mounting.fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be fininshed with 2 coats of red oxide primer paint and finally finishied with approved colour enameled metal paint etc complete.a)14SWG
400
-
200
code50 - Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified
1
2172
2172
code51 - Fixing a ceiling wall mounting fan of all capacities and all types to existing with necessary clamps and S hook made out of 15 mm dia MS rod, with 5 amps, celling rose of approved quality with necessary length of 23.0076 inch PVC insulated twin twisted wire of approved quality, mounted on suitable size wooden board and wired.
1
171
171
code52 - Supplying capacitor type ceiling fan complete with down rod blade,shakle,canopies etc.for operation on 230 volts,50 cycles,single phase AC supply confirming to ISS-374-1979 and with double ball bearing system 1) 48 inch sweep(1200mm) a) regular model
4
2984
11936
code53 - Supplying of TR Invertor type split Air conditioners suitable for operation on AC supply single phase 50Hz 230V with hermetically sealed inverter compressor with air cooled condenser, latest R410A R-32 refrigerant fan motor, start & run capacitors, relay & overload protector internal unit, with one indoor & one outdoor unit The condenser unit will be placed out side the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3 core sheathed PVC copper cable and a battery operated wireless remote unit. 5Star 2 ton
3
67399
202197
code54 - Installation charges for split type airconditioner with allied works for one indoor and one outdoor unit is to b emounted on suitable Angle Iron support upto 3.0 Ton split cassette type AC.
3
3175
9525
code55 - Supplying and installation of insulated refrigerant copper tubing of 5 by 8 inch and 3 by 8 inch with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tube.
45
1549
69705
code56 - Supplying and drawing UTP-CAT 6E LAN cable.
100
38
3800
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%