Karnataka Neeravari Nigam Limited Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Karnataka Neeravari Nigam Limited - KNNL Tender

Works
Civil And Construction
Building Construction
Opening Date11 Nov 2024
Closing Soon30 Nov 2024
Tender Amount₹ 15,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - Providing & fixing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame.

4.93

1337

6594.861

... More
code05 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.

23.06

105

2421.3

... More
code06 - Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge.

23.06

55

1283.289

... More
code07 - Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.

1252.05

115

144611.775

... More
code08 - Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One coats on old work as per specifications and as per directions of Engineer in charge.

145.04

79

11574.192

... More
code09 - Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.

193.2

513

99198.54

... More
code10 - Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer- in-charge: Pre-laminated particle board with decorative lamination on both sides including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.

22.42

1032

23140.803

... More
code11 - Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications.

6.67

1229

8201.0985

... More
code12 - Anodised Aluminium butt hinges 100x75x4 mm

3

41

123.78

... More
code13 - Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.

1

1104

1104.6

... More
code14 - Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.

1

1169

1169.7

... More
code15 - Providing and fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets-grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, stanard hardware and Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm.

7.14

7070

50484.798

... More
code16 - Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.

306.01

142

43698.228

... More
code17 - Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and includingm cutting to size and shape wherever required as per the direction of Engineer in charge. 0.63 mm thick with zinc coating not less than 275 g/ m²

42

922

38763.9

... More
code18 - Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. (0.63 mm thick with zinc coating not less than 275 g/m²) .

21

677

14222.25

... More
code19 - Providing & fixing 100% Polyester Curtains with specification of regular wash as per direction of Engineer in charge. (PWD CSR 2023-24 vol-2, P-219 Item No -22.24)

14.28

1260

17992.8

... More
code20 - Providing and fixing brass curtain rods of wall thickness 1.25 mm with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary Complete . 20 mm diameter. (PWD CSR 2023-24 vol-2, P-199 Item No -20.22.1)

9.8

546

5350.8

... More
code21 - Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter As per PWD SR 2023-24 Vol II item no. 13.48 Page no. 124

36

305

10999.8

... More
code22 - Providing and fixing Three seater Sofa with cushion of size 7(L)x2.5(W) X2.75(H) ft made of upholstery fabric with seats fitted with padding, springs, webbing and as per direction of engineer in charge (PWD CSR 2023-24 vol-2, P-219 Item No -22.16)

1

39375

39375

... More
code23 - GLAM DECOR Revolving Chair with Synchronic tilt mechanism As per GEM Product ID 5116877-28599307048

7

11440

80084.69

... More
code24 - Nilkamal Plastic Moulded Chair Without Arms Without Cushion Separate Plastic Moulded Seat and Back Fitted on Support Structure (Novella chair customize) As per GEM Product ID: 5116877-38459443194 (Reference Attached)

50

1652

82627

... More
code25 - Office Table :BLACKSMITHATTICUS 2100 mm 1110 mm 750 mm (ROYAL-20) As per GEM Product ID: 5116877-466276929 (Reference Attached)

2

33898

67796.6

... More
code26 - Side Table: THE JASMINE PEARL Single storageSide Table, H 750 mm mm X D 400mm THE JASMINE PEARL (TJP SIDE TABLE) As per GEM Product ID: 5116877-16481246352 (Reference Attached)

1

4661

4661.01

... More
code27 - HP LaserJet Tank MFP 2606 SDW Printer with 5 years warranty) As per GEM Product ID: 5116877-92990779901 (Reference Attached)

2

19701

39402.54

... More
code28 - Engaging unskilled Plumber Cum Electrician etc ( Item no II , P.No. A-49, of Common SR Vol-1 of 2023-24 Zone-2)

90

645

58074.3

... More
code29 - Engaging unskilled Cleaner for the maintenance of SE Office etc ( Item no IV , P.No. A-50, of Common SR Vol-1 of 2023-24 Zone-2)

120

615

73802.4

... More
code30 - Supplying heavy gauge PVC Conduct Pipe dia mm thick with suitable size bends, metal junction boxes adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. (Page no.2/105 Item no.1.3.1 of SR of PWD (Electrical) for the year 2023-24) a) 19/20mm dia 2mm thick

50

68

3400

... More
code31 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. (Page no.8/105 Item no.3.4.1 of SR of PWD (Electrical) for the year 2023-24) 1-3 Way

6

138

828

... More
code32 - Extra for groove cutting in brick wall/CC floor to the suitable depth for concealing of conduit/GL pipe and plastering finishing the wall upto wall surface complete. (Page no.3/105 Item no.1.7.1 of f SR of PWD (Electrical) for the year 2023-24).

50

29

1450

... More
code33 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. (Page no.5 Item no. 2.2.1, 2.2.2 , 2.2.4 of SR of PWD (Electrical) for the year 2023-24). a) Short point upto 3mtr from tapping point to out let via switch

4

269

1076

... More
code34 - b)Medium point above 3mtr upto 6mtr from tapping point to outlet via switch

6

379

2274

... More
code35 - C) Two outlet in a row above 3mtr upto 6mtr from tapping point to outlet via switch

6

677

4062

... More
code36 - Wiring for lightining/power cuircuit using one of FRLS PVC insulated 1100 V grade, multistrand copper conducter single core wire in open or concealed system of wiring as per IS-694:1990 & confirming to GTP of GROUP -B. a)1.5 Sqmm (Page no.5/105 Item no. 2.3.2, 2.3.3, 2.3.4 of SR of PWD (Electrical) for the year 2023-24).

120

26

3120

... More
code37 - b) 2.5 Sqmm

100

42

4200

... More
code38 - c) 4 Sqmm

80

63

5040

... More
code39 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (Page no.8/105 Item no. 3.4.3, 3.4.4, 3.4.5 of SR of PWD (Electrical) for the year 2023-24). a) 4-5 Ways

4

177

708

... More
code40 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. (Page no.5 Item no. 3.5.3, 3.5.5, 3.5.6 of SR of PWD (Electrical) for the year 2023-24). a) 4 Module

4

175

700

... More
code41 - b) 8 Module

4

284

1136

... More
code42 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.(Page no.9/105 Item no. 3.6.1, 3.6.3, 3.6.4, 3.6.10, 3.6.11,3.6.12 of SR of PWD (Electrical) for the year 2023-24). a) 6 Amps one way switch

2

102

204

... More
code43 - b) 6 Amps 3 Ways Socket

2

171

342

... More
code44 - c) Stepped Fan Regulator

4

357

1428

... More
code45 - d) TV/Telephone Socket

2

156

312

... More
code46 - e)16 Amps flush type universal socket -do-

25

236

5900

... More
code47 - f) RJ45/I.O Outlet Cat-6

2

337

674

... More
code48 - Supplying 3mm thick hylum plastic sheet with necessary nitches of fixing switches regulators etc and fixing on existing wooden or metal box using N.F.screws (Page no.9/105 Item no.3.9 of SR of PWD (Electrical) for the year 2022-23).

100

-

35

... More
code49 - Extra for supplying 4mm thick white plastic plate and covering for junction boxes of size ……mm conduit using necessary machine screws.(Page no.9/105 Item no.3.10.2, 3.10.3 of SR of PWD (Electrical) for the year 2023-24). a) 80/90 mm

100

15

1500

... More
code50 - b) 110 mm

100

21

2100

... More
code51 - Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board.(Page no.11 Item no.3.14.6 of SR of PWD (Electrical) for the year 2023-24). a) 6 Amps Pendant Holder

25

71

1775

... More
code52 - Supplying of feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours and 70 percent lumen maintenance with CRI more than 80. Power Input: 220-240V at 50 per 60Hz & Power factor more than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. (Page no.43/105 Item no.11.3.2 of SR of PWD (Electrical) for the year 2023-24). a) LED light fighting 1 x4- 20/22 w

12

690

8280

... More
code53 - Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.(Page no.14/105 Item no.5.7.2 of SR of PWD (Electrical) for the year 2023-24). A) 32Amps

4

241

964

... More
code54 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, Indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898 (Page no.13 Item no.5.18.1 of SR of PWD (Electrical) for the year 2023-24) a)6-32 Amps SP

3

415

1245

... More
code55 - Supplying and fixing of retrofit type - LED bulb W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI more than 70 percent. efficacy more than 80 lumen per W, life more than 25000 burning hours and Compliance to IS 10322 per IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF more than 0.95, power loss should less than 5 percent of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20 percent, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. (Page no.47/105 Item no.11.11.7 of SR of PWD (Electrical) for the year 2023-24)

15

426

6390

... More
code56 - Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. (Page no.56/105 Item no.13.7.1 of SR of PWD (Electrical) for the year 2023-24)

15

122

1830

... More
code57 - Fixing of ........amps TPST/Change over swith /contractor along with neutral link with screws,bits,nuts and wiring using required capcity wires and circuit labeling (Page no.57/105 Item no.13.18.1 of SR of PWD (Electrical) for the year 2023-24) a)15A to 63A TPST(28/16)

4

278

1112

... More
code58 - supplying of TPST with rewirable porelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approaved colour (Page no.14/105 Item no.5.5.1 of SR of PWD (Electrical) for the year 2023-24) a) 32Amps

1

1701

1701

... More
code59 - Supplying and fixing of Porecelain fuse channel with cut out on existing wooden/panel using necessary nuts,bolts and washers (Page no.14/105 Item no.5.7.2 of SR of PWD (Electrical) for the year 2023-24) a) 32 Amps

1

241

241

... More
code60 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220V A.C 50 Hz 12/24 v D.C (Page no.19/105 Item no.5.38 of SR of PWD (Electrical) for the year 2023-24)

1

515

515

... More
code61 - Supplying and fixing angle iron frame work fabricated out of MS angle iron and MS flat .... with bolts,washers etc and painted with 2 coats of red oxide and then two coats of approved paint (Page no.20/105 Item no.5.41.1 of SR of PWD (Electrical) for the year 2023-24) a)40x40x6mm

4

305

1220

... More
code62 - Fabricating supplying and mounting MS box made out...... SWG suitable for floor/wall mounting.fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be fininshed with 2 coats of red oxide primer paint and finally finishied with approved colour enameled metal paint etc., complete. (Page no.20/105 Item no.5.42.1 of SR of PWD (Electrical) for the year 2023-24) a) 14SWG

400

-

200

... More
code63 - Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified (Page no.23/105 Item no.51.04 of Bescom -III - 11Kv Material SR for the year 2023-24)

1

2172

2172

... More
code64 - Fixing a ceiling /wall mounting fan of all capacities and all types to existing with necessary clamps and 'S' hook made out of 15 mm dia MS rod, with 5 amps, celling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on suitable size wooden board and wired. (Page no.57/105 Item no.13.10 of SR of PWD (Electrical) for the year 2023-24)

4

171

684

... More
code65 - Supplying capacitor type ceiling fan complete with down rod blade,shakle,canopies etc.,for operation on 230 volts,50 cycles,single phase AC supply confirming to ISS-374-1979 and with double ball bearing system 1) 48" sweep(1200mm) a) regular model (Page no.30/105 Item no.6.3.1 of SR of PWD (Electrical) for the year 2023-24)

4

2984

11936

... More
code66 - Supplying of..TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50Hz 230V with hermetically sealed inverter compressor with air cooled condenser, latest R410A/R-32 refrigerant fan motor, start & run capacitors, relay & overload protector internal unit, with one indoor & one outdoor unit The condenser unit will be placed out side the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit. 5Star 2 ton (Page no.31/105 Item no.6.8.6 of SR of PWD (Electrical) for the year 2023-24)

2

67399

134798

... More
code67 - Supplying of..TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50Hz 230V with hermetically sealed inverter compressor with air cooled condenser, latest R410A/R-32 refrigerant fan motor, start & run capacitors, relay & overload protector internal unit, with one indoor & one outdoor unit The condenser unit will be placed out side the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit. 5Star 1 ton (Page no.31/105 Item no.6.8.4 of SR of PWD (Electrical) for the year 2023-24)

1

47557

47557

... More
code68 - Installation charges for split type airconditioner with allied works for one indoor and one outdoor unit is to b emounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C. (Page no.32/105 Item no.6.12 of SR of PWD (Electrical) for the year 2023-24)

3

3175

9525

... More
code69 - Supplying and installation of insulated refrigerant copper tubing of 5/8"and3/8"with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tube. (Page no.32/105 Item no.6.13.1 of SR of PWD (Electrical) for the year 2023-24)

15

1549

23235

... More
code70 - Supplying and drawing UTP-CAT 6E LAN cable. (Page no.36/105 Item no.8.1 of SR of PWD (Electrical) for the year 2023-24)

100

120

12000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.