Karnataka Housing Board Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Karnataka Housing Board - KHB Tender

Civil And Construction
Building Construction
Opening Date23 Aug 2024
Closing Date6 Sep 2024
Tender Amount₹ 5,96,67,642.86 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - Earth work excavation by manual means for drains,canals, waste weir,draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading,caution lights, removal of stumps and other deleterious matter,excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m.

414.08

271

112232.2432

... More
code05 - Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.

684

132

90397.44

... More
code06 - Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications.

89.4654

3003

268739.747136

... More
code07 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates-

78.19

6992

546716.9904

... More
code08 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-P-15

227.16

7664

1740961.0548

... More
code09 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-

20.16

12063

243204.9984

... More
code10 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-

97.31

8430

820379.7398

... More
code11 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-

20.19

11496

232109.0856

... More
code12 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.-

937.46

297

279288.0832

... More
code13 - Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work.

3203.29

95

304953.208

... More
code14 - Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)-

40.05

7155

286584.984

... More
code15 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates-

2.67

6992

18669.0672

... More
code16 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates--LOWER GROUND FLOOR

61.07

13029

795685.3049

... More
code17 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates--UPPER GROUND FLOOR

38.48

13029

501358.6136

... More
code18 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates--FIRST FLOOR (BALCONY LEVEL)

36.17

13159

475974.0512

... More
code19 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates--SECOND FLOOR

27.45

13289

364800.8925

... More
code20 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates--TERRACE FLOOR

6.93

13419

93000.1842

... More
code21 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.- Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates--TERRACE FLOOR

11.66

12192

142161.9848

... More
code22 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC LINTEL--LOWER GROUND FLOOR

0.31

12262

3801.4246

... More
code23 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC LINTEL--UPPER GROUND FLOOR

7.61

12262

93318.8426

... More
code24 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC LINTEL--FIRST FLOOR (BALCONY LEVEL)

6.16

12385

76293.3248

... More
code25 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC LINTEL--SECOND FLOOR

4.4

12507

55034.804

... More
code26 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC LINTEL--TERRACE FLOOR

1.1

12630

13893.594

... More
code27 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates-CILL CONCRETE-LOWER GROUND FLOOR

0.31

10138

3142.9753

... More
code28 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates-CILL CONCRETE-UPPER GROUND FLOOR

3.81

10138

38628.1803

... More
code29 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates-CILL CONCRETE-FIRST FLOOR (BALCONY LEVEL)

3.08

10240

31539.2616

... More
code30 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates-CILL CONCRETE-SECOND FLOOR

2.2

10341

22751.08

... More
code31 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates-CILL CONCRETE-TERRACE FLOOR

0.55

10442

5743.5345

... More
code32 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC STAIRCASE-LOWER GROUND FLOOR

4.45

11496

51158.268

... More
code33 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC STAIRCASE-UPPER GROUND FLOOR

19.09

11496

219463.2216

... More
code34 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC STAIRCASE-FIRST FLOOR(BALCONY LEVEL)

9.34

11611

108448.608

... More
code35 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC STAIRCASE-SECOND FLOOR

4.45

11726

52181.412

... More
code36 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC BEAM-LOWER GROUND FLOOR

57.66

12262

707064.9756

... More
code37 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC BEAM-UPPER GROUND FLOOR

41.51

12262

509023.0166

... More
code38 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC BEAM-FIRST FLOOR (BALCONY LEVEL)

38.87

12385

481415.8336

... More
code39 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC BEAM-SECOND FLOOR

46.85

12507

585995.5835

... More
code40 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC BEAM-TERRACE FLOOR

4.06

12630

51279.9924

... More
code41 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC SLAB-LOWER GROUND FLOOR

89.6

11496

1030063.104

... More
code42 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC SLAB--UPPER GROUND FLOOR

63.55

11496

730586.052

... More
code43 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC SLAB--FIRST FLOOR(BALCONY LEVEL)

52.3

11611

607265.76

... More
code44 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC SLAB--SECOND FLOOR

11.89

11726

139424.0424

... More
code45 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC SLAB--TERRACE FLOOR

6

11841

71046.78

... More
code46 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC CHAJJA-GROUND FLOOR

4.22

11113

46896.9866

... More
code47 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC CHAJJA-FIRST FLOOR(BALCONY LEVEL)

2.53

11224

28397.1248

... More
code48 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-RCC CHAJJA-SECOND FLOOR

3.85

11335

43640.8665

... More
code49 - Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications.-GROUND FLOOR

4.22

1386

5851.2832

... More
code50 - Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications.-FIRST FLOOR

2.53

1400

3543.0879

... More
code51 - Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications.-SECOND FLOOR

3.85

1414

5445.0165

... More
code52 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a) Buildings-

125.19

100191

12543016.4496

... More
code53 - Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.-UPPER GROUND

63.88

2259

144307.4752

... More
code54 - Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.-FIRST FLOOR(BALCONY LEVEL)

32.2

2281

73468.486

... More
code55 - Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.-SECOND FLOOR

5.63

2304

12972.7586

... More
code56 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates-UPPER GROUND

23.95

6963

166764.808

... More
code57 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates-FIRST FLOOR(BALCONY LEVEL)

12.07

7032

84884.3269

... More
code58 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates-SECOND FLOOR

2.11

7102

14985.853

... More
code59 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.-UPPER GROUND

16.22

415

6739.7344

... More
code60 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.-FIRST FLOOR(BALCONY LEVEL)

160.99

419

67564.2832

... More
code61 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.-SECOND FLOOR

28.17

423

11939.2911

... More
code62 - Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6.-LOWER GROUND FLOOR

4.89

7565

36995.784

... More
code63 - Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6.--UPPER GROUND FLOOR

137.07

7565

1037016.792

... More
code64 - Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6.--FIRST FLOOR(BALCONY LEVEL)

104.95

7641

801950.237

... More
code65 - Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6.--SECOND FLOOR

104.95

7716

809889.7045

... More
code66 - Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6.--TERRACE FLOOR

20.87

7792

162630.9359

... More
code67 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.GROUND FLOOR

63.9

1467

93754.08

... More
code68 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.-FIRST FLOOR(BALCONY LEVEL)

63.9

1481

94691.493

... More
code69 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.-SECOND FLOOR

41.4

1496

61956.756

... More
code70 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.TERRACE FLOOR

30.9

1511

46696.698

... More
code71 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.--GROUND FLOOR

38.82

1378

53521.9104

... More
code72 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.-FIRST FLOOR (BALCONY LEVEL)

31.95

1392

44490.6945

... More
code73 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.-SECOND FLOOR

23.52

1406

33075.9408

... More
code74 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.-TERRACE FLOOR

23.52

1420

33400.2816

... More
code75 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.--GROUND FLOOR

67.47

1236

83425.3056

... More
code76 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.--FIRST FLOOR (BALCONY LEVEL)

50.13

1248

62604.3492

... More
code77 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.--SECOND FLOOR

2.35

1261

2963.8435

... More
code78 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.--TERRACE FLOOR

135.3

1273

172314.021

... More
code79 - Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. Sl.No 12.11, Page No.99, Volume- II, GROUND FLOOR.

0.98

154642

151550.0224

... More
code80 - Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications--LOWER GROUND FLOOR

0.12

111552

13386.24

... More
code81 - Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications--UPPER GROUND FLOOR

1.15

111552

128284.8

... More
code82 - Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications--FIRST FLOOR ( BALCONY LEVEL)

1.15

112667

129567.648

... More
code83 - Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications--SECOND FLOOR

1.15

113783

130850.496

... More
code84 - Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications--TERRACE FLOOR

0.1

114898

11489.856

... More
code85 - Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.UPPER GROUND FLOOR

38.4

720

27654.144

... More
code86 - Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.FIRST FLOOR (BALCONY LEVEL)

32

727

23275.52

... More
code87 - Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.-SECOND FLOOR

6.4

734

4701.184

... More
code88 - Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)-LOWER GROUND FLOOR

3.6

7542

27151.488

... More
code89 - Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)-UPPER GROUND FLOOR

93.42

7542

704581.1136

... More
code90 - Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)-FIRST FLOOR (BALCONY LEVEL)

71.82

7617

547088.85

... More
code91 - Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)-SECOND FLOOR

18.9

7692

145396.188

... More
code92 - Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)TERRACE FLOOR

2.43

7768

18877.0662

... More
code93 - Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)- -LOER GROUND

13.05

6405

83588.904

... More
code94 - Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)- -UPPER GROUND FLOOR

13.05

6405

83588.904

... More
code95 - Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)- -FIRST FLOOR (BALCONY LEVEL)

5.13

6469

33187.6629

... More
code96 - Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)- SECOND FLOOR

2.97

6533

19404.1683

... More
code97 - Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.-UPPER GROUND FLOOR

6

8906

53437.44

... More
code98 - Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.\FIRST FLOOR(BALCONYLEVEL)

6

8995

53971.8

... More
code99 - Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.SECOND FLOOR

6

9084

54506.16

... More
code100 - Providing and fixing in position fully panelled Honne wood shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures ) Sl. No. 12.20 Page No. 100, Volume-II -UPPER GROUND FLOOR

13.23

6888

91128.24

... More
code101 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-35 mm thick both side commercial-LOWER GROUND FLOOR

2.57

3720

9562.0448

... More
code102 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-35 mm thick both side commercial-UPPER GROUND FLOOR

24.82

3720

92346.2848

... More
code103 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-35 mm thick both side commercialFIRST FLOOR (BALCONY LEVEL)

8.13

3757

30551.3205

... More
code104 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-35 mm thick both side commercial-SECOND FLOOR

5.15

3795

19544.5075

... More
code105 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-35 mm thick both side commercial-TERRACE FLOOR

2.94

3832

11266.8444

... More
code106 - Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.- 30 mm thickness--UPPER GROUND FLOOR

9.68

3588

34736.4864

... More
code107 - Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.- 30 mm thickness-FIRST FLOOR (BALCONY LEVEL)

9.68

3624

35083.8048

... More
code108 - Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.- 30 mm thickness-SECOND FLOOR

3.23

3660

11822.6075

... More
code109 - Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge.TERRACE FLOOR

2.45

5165

12656.259

... More
code110 - Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.-GROUND FLOOR

9

1137

10241.28

... More
code111 - Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.--SECOND FLOOR

12

1149

13791.6

... More
code112 - Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.-SECOND FLOOR

11

1160

12767.48

... More
code113 - Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.--TERRACE FLOOR

1

1172

1172.06

... More
code114 - Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.

66

134

8870.4

... More
code115 - Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete-

66

1178

77763.84

... More
code116 - Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete-

66

265

17519.04

... More
code117 - Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10mm,

66

487

32155.2

... More
code118 - Providing and fixing bright finished brass butt hinges with necessary screws etc. complete :-125x85x5.5mm.(heavy type) Sl.no-12.75.1, pg.no-107,volume-2.

496

308

152768

... More
code119 - Providing and fixing bright finished brass butt hinges with necessary screws etc. complete :-100x85x5.5mm.(heavy type) Sl.no-12.75.3, pg.no-107,volume-2.

81

229

18597.6

... More
code120 - Providing and fixing MS Hold fasts (SL. No 444,Page No.A-25, Basic Rate Rs. 50.00), volume-2.

198

56

11088

... More
code121 - Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms-SL.NO-12.64, PG.NO-105,VOLUME-2.

60

61

3696

... More
code122 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding,-LOWER GROUND FLOOR

64.8

188

12192.768

... More
code123 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding,-UPPER GROUND FLOOR

1681.56

188

316402.3296

... More
code124 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding,-FIRST FLOOR (BALCONY LEVEL)

1292.76

190

245676.1104

... More
code125 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding,-SECOND FLOOR

340.2

191

65291.184

... More
code126 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding,-TERRACE FLOOR

291.6

193

56512.08

... More
code127 - Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of EngineerIn-charge.. Sl. No. 8.6.1, Page No. 42, Volume-2.LOWER GROUND FLOOR

597.36

361

216100.9536

... More
code128 - Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerin-charge.. Sl. No. 8.6.1, Page No. 42, Volume-2.-UPPER GROUND FLOOR

732.36

361

264938.5536

... More
code129 - Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in-charge.. Sl. No. 8.6.1, Page No. 42, Volume-2.-FIRST FLOOR (BALCONY LEVEL)

1056.1

365

385877.818

... More
code130 - Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in-charge.. Sl. No. 8.6.1, Page No. 42, Volume-2.-SECOND FLOOR

402.5

369

148522.5

... More
code131 - Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in-charge.. Sl. No. 8.6.1, Page No. 42, Volume-2.-TERRACE FLOOR

57.55

372

21443.7055

... More
code132 - Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in-charge.. Sl. No. 8.6.1, Page No. 42, Volume-2.-LOWER GROUND FLOOR

119.47

361

43219.4672

... More
code133 - Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in-charge.. Sl. No. 8.6.1, Page No. 42, Volume-2.-UPPER GROUND FLOOR

146.47

361

52986.9872

... More
code134 - Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in-charge.. Sl. No. 8.6.1, Page No. 42, Volume-2.-FIRST FLOOR (BALCONY LEVEL)

211.22

365

77175.5636

... More
code135 - Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in-charge.. Sl. No. 8.6.1, Page No. 42, Volume-2.-SECOND FLOOR

80.5

369

29704.5

... More
code136 - Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in-charge.. Sl. No. 8.6.1, Page No. 42, Volume-2.-TERRACE FLOOR

11.51

372

4288.7411

... More
code137 - Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment-Plaster mesh 150mm wide-LOWER GROUND FLOOR

477.89

42

20338.9984

... More
code138 - Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment-Plaster mesh 150mm wide-UPPER GROUND FLOOR

585.89

42

24935.4784

... More
code139 - Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment-Plaster mesh 150mm wide-FIRST FLOOR (BALCONY LEVEL)

844.88

42

36321.3912

... More
code140 - Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment-Plaster mesh 150mm wide-SECOND FLOOR

322

43

13978.02

... More
code141 - Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment-Plaster mesh 150mm wide-TERRACE FLOOR

46.04

43

2018.3936

... More
code142 - Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42, Volume-2.-LOWER GROUND FLOOR

493.63

409

202348.8096

... More
code143 - Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42, Volume-2.UPPER GROUND FLOOR

994.67

409

407735.1264

... More
code144 - Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42, Volume-2.-FIRST FLOOR (BALCONY LEVEL)

1008.36

414

417481.2072

... More
code145 - Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42, Volume-2.-SECOND FLOOR

951.62

418

397891.3544

... More
code146 - Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42, Volume-2.-TERRACE FLOOR

68.9

422

29090.958

... More
code147 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No. 8.2.1, Page No.41, Volume- 2.-UPPER GROUND FLOOR

156.84

330

51819.936

... More
code148 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No. 8.2.1, Page No.41, Volume- 2.-FIRST FLOOR (BALCONY LEVEL)

106.77

333

35629.149

... More
code149 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No. 8.2.1, Page No.41, Volume- 2.-SECOND FLOOR

16.08

337

5419.1208

... More
code150 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.9, Page No.42, Volume-2.-LOWER GROUND FLOOR

499.5

431

215384.4

... More
code151 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.9, Page No.42, Volume-2.-UPPER GROUND FLOOR

545

431

235004

... More
code152 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.9, Page No.42, Volume-2.FIRST FLOOR (BALCONY LEVEL)

548.5

435

238877.235

... More
code153 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.9, Page No.42, Volume-2.-SECOND FLOOR

514.2

439

226155.444

... More
code154 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.9, Page No.42, Volume-2.-TERRACE FLOOR

343

444

152340.02

... More
code155 - Providing ruled pointing to coursed stone masonry with lime mortar 1:3, 20mm deep, after raking joints to depth of 20mm nicely lining, including cost all materials, labour, usage charges of machinery, curing complete as per specification.-GROUND FLOOR

121

334

40520.48

... More
code156 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates-Page 15, Sl. No.2.1.6, Volume-I-LOWER GROUND FLOOR

69.5

6992

485955.12

... More
code157 - Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.-GROUND FLOOR

666.43

3194

2128737.3632

... More
code158 - Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.-FIRST FLOOR (BALCONY LEVEL)

287.91

3226

928849.4838

... More
code159 - Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.SECOND FLOOR

134.79

3258

439161.9948

... More
code160 - Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.LOWER GROUND FLOOR

30.69

5967

183138.2784

... More
code161 - Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.-UPPER GROUND FLOOR

100.6

5967

600316.416

... More
code162 - Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.-FIRST FLOOR (BALCONY LEVEL)

57.29

6027

345288.5487

... More
code163 - Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 (1 cement : 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete-GROUND FLOOR

58.5

3762

220081.68

... More
code164 - Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 (1 cement : 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete-FIRST FLOOR

45

3799

170986.5

... More
code165 - Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 (1 cement : 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., completeSECOND FLOOR

45

3837

172679.4

... More
code166 - Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete..-- Size of Tile 600x600 mm-LOWER GROUND FLOOR

6.36

1282

8156.064

... More
code167 - Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete..-- Size of Tile 600x600 mm-UPPER GROUND FLOOR

60.34

1282

77380.016

... More
code168 - Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete..-- Size of Tile 600x600 mm-FIRST FLOOR (BALCONY LEVEL)

35.1

1295

45462.222

... More
code169 - Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete..-- Size of Tile 600x600 mmSECOND FLOOR

66.15

1308

86527.5075

... More
code170 - Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Sl.No 10.14, Page No.71, Volume-2.-UPPER GROUND FLOOR

156.84

1238

194280.8448

... More
code171 - Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Sl.No 10.14, Page No.71, Volume-2.-FIRST FLOOR

106.77

1251

133581.0147

... More
code172 - Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Sl.No 10.14, Page No.71, Volume-2.-SECOND FLOOR

16.08

1263

20316.9192

... More
code173 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete.-UPPER GROUND FLOOR

19.34

1205

23307.0208

... More
code174 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete.-FIRST FLOOR (BALCONY LEVEL)

22.74

1217

27678.4458

... More
code175 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete.-SECOND FLOOR

3.47

1229

4265.3934

... More
code176 - Providing and laying flooring and steps machine cut granite slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specifications.-UPPER GROUND FLOOR

10.1

4792

48404.048

... More
code177 - Providing and laying flooring and steps machine cut granite slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specifications.-FIRST FLOOR (BALCONY LEVEL)

7.56

4840

36593.424

... More
code178 - Providing and laying flooring and steps machine cut granite slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specifications.-SECOND FLOOR

1.2

4888

5865.996

... More
code179 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sl.No 8.51, Page No.50, Volume-2..-UPPER GROUND FLOOR

1434.62

112

160677.44

... More
code180 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sl.No 8.51, Page No.50, Volume-2..-GROUND FLOOR

1873.5

112

209832

... More
code181 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sl.No 8.51, Page No.50, Volume-2..-FIRST FLOOR

2275.68

113

257424.9216

... More
code182 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sl.No 8.51, Page No.50, Volume-2..-SECOND FLOOR

1434.62

114

163890.9888

... More
code183 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sl.No 8.51, Page No.50, Volume-2..-TERRACE FLOOR

137.96

115

15915.0656

... More
code184 - Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.33.1, Page No.46, Volume-2.-UPPER GROUND FLOOR

402.5

176

71226.4

... More
code185 - Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.33.1, Page No.46, Volume-2.-GROUND FLOOR

732.36

176

129598.4256

... More
code186 - Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.33.1, Page No.46, Volume-2.-FIRST FLOOR

1056.1

178

188756.753

... More
code187 - Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.33.1, Page No.46, Volume-2.-SECOND FLOOR

402.5

180

72651.25

... More
code188 - Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.33.1, Page No.46, Volume-2.-TERRACE FLOOR

57.55

182

10489.6385

... More
code189 - Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life)-UPPER GROUND FLOOR

951.62

176

168398.6752

... More
code190 - Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life)-GROUND FLOOR

994.67

176

176016.8032

... More
code191 - Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life)-FIRST FLOOR

1008.36

178

180224.1828

... More
code192 - Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life)-SECOND FLOOR

951.62

180

171767.41

... More
code193 - Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life)-TERRACE FLOOR

68.9

182

12558.403

... More
code194 - Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-UPPER GROUND FLOOR

77.13

316

24447.1248

... More
code195 - Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-GROUND FLOOR

81.75

316

25911.48

... More
code196 - Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-FIRST FLOOR

82.28

320

26340.2964

... More
code197 - Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-SECOND FLOOR

77.13

323

24936.129

... More
code198 - Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-TERRACE FLOOR

34.3

326

11197.921

... More
code199 - Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.30, Page No.46, Volume-2.-UPPER GROUND FLOOR

411.36

194

80165.8368

... More
code200 - Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.30, Page No.46, Volume-2.-GROUND FLOOR

436

194

84967.68

... More
code201 - Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.30, Page No.46, Volume-2.-FIRST FLOOR

438.8

196

86369.004

... More
code202 - Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.30, Page No.46, Volume-2.-SECOND FLOOR

411.36

198

81770.1408

... More
code203 - Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.30, Page No.46, Volume-2.-TERRACE FLOOR

274.4

200

55080.312

... More
code204 - Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.41,Page No.48, Volume-2.-LOWER GROUND FLOOR

7.2

187

1346.688

... More
code205 - Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.41,Page No.48, Volume-2.-GROUND FLOOR

186.84

187

34946.5536

... More
code206 - Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.41,Page No.48, Volume-2.-FIRST FLOOR

143.64

188

27135.0324

... More
code207 - Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.41,Page No.48, Volume-2.-SECOND FLOOR

37.8

190

7211.484

... More
code208 - Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.41,Page No.48, Volume-2.-TERRACE FLOOR

6.08

192

1171.312

... More
code209 - Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge.Sl.No 8.55.1, Page No.50, Volume-2.-LOWER GROUND FLOOR

6.43

62

403.2896

... More
code210 - Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge.Sl.No 8.55.1, Page No.50, Volume-2.-GROUND FLOOR

95.12

62

5965.9264

... More
code211 - Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge.Sl.No 8.55.1, Page No.50, Volume-2.-FIRST FLOOR

20.34

63

1288.539

... More
code212 - Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge.Sl.No 8.55.1, Page No.50, Volume-2.-SECOND FLOOR

20.21

63

1292.8337

... More
code213 - Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.sl.no-8.47, pg.no-49,volume-2.-GROUND FLOOR

95.12

151

14382.144

... More
code214 - Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.sl.no-8.47, pg.no-49,volume-2.-FIRST FLOOR

20.34

152

3106.1214

... More
code215 - Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.sl.no-8.47, pg.no-49,volume-2.-SECOND FLOOR

20.21

154

3116.7862

... More
code216 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sl.No 11.28, Page No.85, Volume-2.-LOWER GROUND FLOOR

7.56

632

4783.968

... More
code217 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sl.No 11.28, Page No.85, Volume-2.-UPPER GROUND FLOOR

214.2

632

135545.76

... More
code218 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sl.No 11.28, Page No.85, Volume-2.-FIRST FLOOR (BALCONY LEVEL)

212.04

639

135521.1252

... More
code219 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sl.No 11.28, Page No.85, Volume-2.-SECOND FLOOR

45.36

645

29278.0656

... More
code220 - Providing and fixing ion wall face unplasticised Rigid PVC rain water pipes confirming to IS :13592 Type A,including jointing with seal ring confirming to IS:5382,leaving 10mm gap for thermal expansion,(i) Single socketed pipes 100mm diameter.item no-13.48, volume-2. PG.NO-125.

180

332

59839.2

... More
code221 - Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge

184.25

896

165088

... More
code222 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates.

36.32

7102

257955.536

... More
code223 - Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification

396

915

362355.84

... More
code224 - Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.

7.5

9269

69518.4

... More
code225 - Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin- charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

562.46

602

338932.7714

... More
code226 - Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top cover-

562.46

450

253601.9648

... More
code227 - Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top cover

26.04

1139

29670.2364

... More
code228 - Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top cover

52.08

478

24918.7176

... More
code229 - Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.

5624.64

154

868669.4016

... More
code230 - Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge.

160

1743

279006.4

... More
code231 - PLUMBING AND SANITARY-Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. Sl.No 14.1.1, Page No.131, Volume-II

10

5470

54700.8

... More
code232 - Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid. Sl.No 14.3.1, Page No.131, Volume-II

5

6694

33471.2

... More
code233 - Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer. Sl.No 14.7A, Page No.133, Volume-II

17

4615

78463.84

... More
code234 - Providing and fixing 100 mm sand cast Iron grating for gully trap. Sl.No 14.29, Page No.136, Volume-II.

45

52

2368.8

... More
code235 - Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. Sl.No 13.15, Page No.119, Volume-II

50

812

40600

... More
code236 - Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 g. Sl.No 13.13, Page No.119, Volume-II

50

947

47376

... More
code237 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) Sl.No 13.4, Page No.117, Volume-II-25 mm nominal bore

3

614

1844.64

... More
code238 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) Sl.No 13.4, Page No.117, Volume-II-32 mm nominal bore

3

669

2009.28

... More
code239 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) Sl.No 13.4, Page No.117, Volume-II-40 mm nominal bore

3

786

2358.72

... More
code240 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) Sl.No 13.4, Page No.117, Volume-II-50 mm nominal bore

3

957

2872.8

... More
code241 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) Sl.No 13.4, Page No.117, Volume-II-65 mm nominal bore

3

1277

3833.76

... More
code242 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) Sl.No 13.4, Page No.117, Volume-II-80 mm nominal bore

2

2326

4652.48

... More
code243 - Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Sl.No 14.31, Page No.136, Volume-II

15

1368

20529.6

... More
code244 - 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. Sl.No 14.40.2, Page No.137, Volume-II

15

555

8332.8

... More
code245 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 160mm dia., 6 kg/sqcm & class 3. Sl.No 10.1.9, PG.NO-113, VOLUME-5.

110

692

76137.6

... More
code246 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 110mm dia., 6 kg/sqcm & class 3. Sl.No 10.1.7, PG.NO-113, VOLUME-5.

169

460

77794.08

... More
code247 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 90mm dia., 6 kg/sqcm & class 3. Sl.No 10.1.6, PG.NO-113, VOLUME-5.

185

329

60916.8

... More
code248 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall - 50 mm nominal dia Pipes. Sl.No 13.31.6, PG.NO-122, VOL-2.

105

874

91845.6

... More
code249 - Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc), For 32 mm dia. Sl.No 13.32.4, page-122, VOL-2.

85

623

53026.4

... More
code250 - Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc), For 25 mm dia. Sl.No 13.32.3, page-122, VOL-2.

200

534

106848

... More
code251 - Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc), For 20 mm dia. Sl.No 13.32.2, page-122, VOL-2.

200

424

84896

... More
code252 - Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. Sl.No 16.10,page-191, VOL-5.

10

4744

47443.2

... More
code253 - KSRB 11-18-9.1 : Providing and fixing sand cast iron soil waste single equal junction of required degree with access door 100x100x100mm, including cost of materials, labour, testing complete as per specifications. Specification No. KBS 11.1.10,

20

1044

20899.2

... More
code254 - Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Sl.No 13.34, page-123, VOL-2.

5000

10

50400

... More
code255 - Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc, complete. 5.00 HP/3.7KW, 25 STG.

1

29568

29568

... More
code256 - INTERNAL WIRING -Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. and running before Concreting the Slab. The Conduit should be tied to the reenforcement Rods by using binding wires and the unused ways of Junction boxes should be covered using PVC End enclosures .run with 18 SWG GI finish wire wherever it is necessory-19/20mm Dia 2mm Thick

1496

61

91256

... More
code257 - Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. and running before Concreting the Slab. The Conduit should be tied to the reenforcement Rods by using binding wires and the unused ways of Junction boxes should be covered using PVC End enclosures .run with 18 SWG GI finish wire wherever it is necessory-19/20mm Dia 2mm Thick-25mm dia 2mm Thick

2059

70

144130

... More
code258 - Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. and running before Concreting the Slab. The Conduit should be tied to the reenforcement Rods by using binding wires and the unused ways of Junction boxes should be covered using PVC End enclosures .run with 18 SWG GI finish wire wherever it is necessory-19/20mm Dia 2mm Thick-32mm dia 2.5mm thick

50

93

4650

... More
code259 - Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and plastering upto wall surface and .run with 18 SWG GI finish wire wherever it is necessory-19/20mm Dia 2mm Thick

1100

75

82500

... More
code260 - Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and plastering upto wall surface and .run with 18 SWG GI finish wire wherever it is necessory-25mm dia 2mm Thick

1100

80

88000

... More
code261 - Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and plastering upto wall surface and .run with 18 SWG GI finish wire wherever it is necessory-32mm dia 2.5mm thick

60

105

6300

... More
code262 - Supplying and fixing PVC/ Metal Conduit Deep Junction Boxes-19/20 mm Deep Junction Box

239

49

11711

... More
code263 - Supplying and fixing PVC/ Metal Conduit Deep Junction Boxes-25 mm Deep Junction Box

87

51

4437

... More
code264 - Supplying and fixing PVC/ Metal Conduit Deep Junction Boxes-32 mm deep Junction Box

30

69

2070

... More
code265 - Supplying and fixing PVC Casing and capping on the wall or ceiling using materials like bend , screws at an interval 0f 300 mm etc-20 mm

150

27

4050

... More
code266 - Supplying and fixing PVC Casing and capping on the wall or ceiling using materials like bend , screws at an interval 0f 300 mm etc-25 mm

150

28

4200

... More
code267 - Supplying and fixing PVC Casing and capping on the wall or ceiling using materials like bend , screws at an interval 0f 300 mm etc-32 mm

50

41

2050

... More
code268 - Supplying PVC /GI flexible conduit pipe …. Mm dia fixing on surface cover inverted tapared wodden plugs or phill plugs or rawl plugs and clamped using heavy guage saddles in an interval of 300 mm using NF screws and on the eaiter end of the pipe terminated properly-20 mm

200

25

5000

... More
code269 - Supplying PVC /GI flexible conduit pipe …. Mm dia fixing on surface cover inverted tapared wodden plugs or phill plugs or rawl plugs and clamped using heavy guage saddles in an interval of 300 mm using NF screws and on the eaiter end of the pipe terminated properly-25 mm

200

31

6200

... More
code270 - Supply & Fixing of Metal fan box with round Hook

45

163

7335

... More
code271 - Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet.-Make : KEI / Polycab/ Finolex-Short point upto 3 Mtd. From Tapping point to outlet via switch box.

115

251

28865

... More
code272 - Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet.-Make : KEI / Polycab/ Finolex-Medium point above 3 Mts upto 6 Mts. From tapping point to outlet via switch box.

110

361

39710

... More
code273 - Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet.-Make : KEI / Polycab/ Finolex-Long point above 6 Mts. Upto 10 Mts. From tapping of point to outlet via switch box.

85

542

46070

... More
code274 - Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet.-Make : KEI / Polycab/ Finolex-Two outlet in a row above 3 Mts upto 6 Mts, from tapping point to outlet via switch box.

25

671

16775

... More
code275 - Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet.-Make : KEI / Polycab/ Finolex-Three outlet in a row, above 6 Mts. Upto 10 Mts. From tapping point to outlet via switch box.

32

979

31328

... More
code276 - Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring-1.5 Sqmm

2659

26

69134

... More
code277 - Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring-2.5Sqmm

3695

40

147800

... More
code278 - Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring-4Sqmm

2600

59

153400

... More
code279 - Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring-10Sqmm

300

157

47100

... More
code280 - Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring-16Sqmm

200

318

63600

... More
code281 - Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall-Make : Anchor / Schneider / Legrand-1-3 way

35

123

4305

... More
code282 - Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall-Make : Anchor / Schneider / Legrand-4-5 way

30

138

4140

... More
code283 - Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall-Make : Anchor / Schneider / Legrand-6 way

18

212

3816

... More
code284 - Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall-Make : Anchor / Schneider / Legrand-8 way

13

250

3250

... More
code285 - Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall-Make : Anchor / Schneider / Legrand-12 way

8

325

2600

... More
code286 - Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall-Make : Anchor / Schneider / Legrand-16 way

6

354

2124

... More
code287 - Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box1-3 way

35

152

5320

... More
code288 - Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box-4-5 way

30

175

5250

... More
code289 - Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box-6 way

18

244

4392

... More
code290 - Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box-8 way

13

302

3926

... More
code291 - Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box-10-12 way

12

363

4356

... More
code292 - Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box-16 way

10

403

4030

... More
code293 - Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate -6 Amp one way

188

88

16544

... More
code294 - Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate -6 Amps 2 way

12

152

1824

... More
code295 - Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate -6 Amps socket

65

162

10530

... More
code296 - Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate -Stepped Fan Regulator

45

313

14085

... More
code297 - Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate -16 Amps 1 way switch

61

249

15189

... More
code298 - Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate -6 Amps Bell Push

2

159

318

... More
code299 - Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate -32 Amps DP Switch

55

375

20625

... More
code300 - Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate -6/16 Amps universal socket

61

249

15189

... More
code301 - Supply and fixing of -Led Light Fixture 2 feet - 9/10 W-Make : Panasonic/Phillips / Crompton

17

496

8432

... More
code302 - Supply and fixing of -Led Light Fixture 4 feet - 20/22 W

61

740

45140

... More
code303 - Supply of recess mounted rolling type LED square or round Light 12 watta

56

835

46760

... More
code304 - Supply and fixing of -LED Modular Down Light 2' x 2 ' - 36 W

92

5651

519892

... More
code305 - Fabrication and supply of sheet steel enclosure out of 14 SWG CRCA Sheet duly powder coated the contro panel ( Size of 2000 x1500x 450 ) is of compartment alized, All the components are duly wired and connected to Aluminum bus bar.-Make : Legrand / Schneider / Anchor / L&T

70000

-

30100

... More
code306 - Supplying and fixing of 100 A 4 x 30 x 10 mm Alumunium Strips

6

2214

13284

... More
code307 - Supplying and fixing of 400 A 4 x 50 x 10 mm Alumunium Strips

6

3996

23976

... More
code308 - Supplying and fixing-16 sqmm wire

40

318

12720

... More
code309 - Supplying and fixing of LED Panel Board indicating Lamp with required colour Suitable for 220 V AC 50 HZ

9

464

4176

... More
code310 - Supplying of Multifunction Digital Meter

1

8370

8370

... More
code311 - Supplying and fixing-250A ATS

1

102600

102600

... More
code312 - Supplying and fixing of 400 A MCCB

1

29092

29092

... More
code313 - Supplying and fixing of 200 A MCCB

1

21289

21289

... More
code314 - Supplying and fixing-63A 4P MCB

6

2399

14394

... More
code315 - Supplying and fixing-5 - 32 A TPN

13

1777

23101

... More
code316 - Supplying and fixing of Earth leakage relay

1

8316

8316

... More
code317 - Supplying and fixing of 50 x 50 x 6 mm Angle

20

356

7120

... More
code318 - Fabrication and supply of sheet steel enclosure out of 14 SWG CRCA Sheet duly powder coated the contro panel ( Size of 2000 x1500x 450 ) is of compartment alized, All the components are duly wired and connected to Aluminum bus bar.

35000

-

15050

... More
code319 - Supplying and fixing of 100 A 4 x 30 x 10 mm Alumunium Strips

6

2214

13284

... More
code320 - Supplying and fixing of LED Panel Board indicating Lamp with required colour Suitable for 220 V AC 50 HZ

15

464

6960

... More
code321 - Supply , fixing and wiring of Automatic Poer Factor Controller

1

19440

19440

... More
code322 - Supplying and fixing of 40 - 63 Amps TPN MCB

1

2399

2399

... More
code323 - Supplying and fixing of 5 - 32 A TPN

6

1777

10662

... More
code324 - Supplying and fixing of 25 Amps

6

1187

7122

... More
code325 - Supplying and fixing of Heavy Duty low Voltage Capacitors

30

432

12960

... More
code326 - Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting -Double Door-4Way SP &N

1

1368

1368

... More
code327 - Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting -Double Door-8Way SP &N

1

1695

1695

... More
code328 - Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting -Double Door-12Way SP &N

1

2067

2067

... More
code329 - Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting -Double Door-6Way TP &N

1

3735

3735

... More
code330 - Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting -Double Door-8Way TP &N

2

4136

8272

... More
code331 - Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting -Double Door-12Way TP &N

3

5744

17232

... More
code332 - Supplying fixing & wiring earth leakage miniature circuit breaker (ELMCB) 240 / 450 V up to 300mA sensitivity on Existing / panel Board-16 - 25 Amps 2 pole

3

2536

7608

... More
code333 - Supplying fixing & wiring earth leakage miniature circuit breaker (ELMCB) 240 / 450 V up to 300mA sensitivity on Existing / panel Board-32 - 40 Amps 2 pole

10

2652

26520

... More
code334 - Supplying fixing & wiring earth leakage miniature circuit breaker (ELMCB) 240 / 450 V up to 300mA sensitivity on Existing / panel Board-32 - 40 Amps 4 pole

2

2826

5652

... More
code335 - Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898-5 - 32 Amp SP

70

523

36610

... More
code336 - Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898-40 - 63 Amps SP

4

726

2904

... More
code337 - Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898-5 - 32 Amp DP

6

1103

6618

... More
code338 - Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898-40 - 63 Amp DP

6

1376

8256

... More
code339 - Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898-5 - 32 A TPN

2

1777

3554

... More
code340 - Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898-40 - 63 Amp TPN

6

2399

14394

... More
code341 - Supplying Fixing and Wiring earth electrode for grounding of lifts,Xmer, DG Sets etc using 40mm dia 2.9mm thick, 2.5mtr long GI pipe with GI funnel with mesh & suitable size reducer fixed on the top of Electrode. The funnel should be enclosed in a cc chamber of 400x400x400 with a cast iron cover. The Earth electrode shall have staggered holes of 12mm dia & electrode shoulde be covered 150mm around with alternate layers of salt & charcoal from the bottom of the CC Chamber. The connection from the electrode is to be established throgh GI strip using GI bolts & nuts.

8

4150

33200

... More
code342 - Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required….. 25 x 3 mm G.I strip.GI Strip

100

75

7500

... More
code343 - Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required….. 600x600x3 GI Plate.GI Strip

2

760

1520

... More
code344 - Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required…..-25 x 3 mm -Cu. Strip

50

505

25250

... More
code345 - Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required…..-600x600x3 Cu. Plate-Cu. Strip

2

6900

13800

... More
code346 - Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required…-12 SWG GI wire-GI wire

200

14

2800

... More
code347 - Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required-12 SWG

50

58

2900

... More
code348 - Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required10 SWG

50

68

3400

... More
code349 - Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required-8 SWG

50

105

5250

... More
code350 - Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required-2C x 10sq.mm. Al. Alum. Cable

200

95

19000

... More
code351 - Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required-4C x 10sq.mm. Al. Alum. Cable

150

130

19500

... More
code352 - Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required-4C x 16sq.mm. Al. Alum. Cable

100

150

15000

... More
code353 - Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required-3.5C x 120sq.mm. Al. Alum. Cable

50

600

30000

... More
code354 - Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required-3.5C x 240sq.mm. Al. Alum. Cable

100

1130

113000

... More
code355 - Supply & Fixing of Heavy Duty Cable Glands Suitable For UG Cable of 1.1KV Class (metal Only)-25mm Dia

30

84

2520

... More
code356 - Supply & Fixing of Heavy Duty Cable Glands Suitable For UG Cable of 1.1KV Class (metal Only)-63mm Dia

8

388

3104

... More
code357 - Supplying Tinned Cu. Lugs & crimping & wiring to terminal Point for Wire of following sizes -16sq.mm. long Barrel

18

12

223.92

... More
code358 - Supplying Tinned Cu. Lugs & crimping & wiring to terminal Point for Wire of following sizes -240Sqmm Long Barrel

6

463

2778

... More
code359 - Supplying Tinned Cu. Lugs & crimping & wiring to terminal Point for Wire of following sizes -120 Sqmm Long Barrel

50

190

9500

... More
code360 - Supply & Fixing 2mm thick perforated cable tray with powder coated paint on exising MS Angle support using necessary GI bolts , nuts & washer or welding as required:-150 mmX 50 MM wide tray ( Perforated type )

20

425

8500

... More
code361 - Supply & Fixing 2mm thick perforated cable tray with powder coated paint on exising MS Angle support using necessary GI bolts , nuts & washer or welding as required:-300 mm x 50 mm wide cabel tray ( Perforated type )

20

530

10600

... More
code362 - Supplying exhaust fan 0f 1440 RPM of300 mm (12") size with bracket blades complte for light duty suitable to operate on 230V 50 Hz AC Supply-Make Fans : Crompton / Usha / Anchor

15

1542

23130

... More
code363 - Supplying capacitor type ceiling Fan complete with down rod blades shackle ,canopies etc. for operation on 230 Vots 50 cycles ,single phase AC supply confirming to ISS -374-1979 with double ball bearing system-48 " Sweep Economy model

35

2085

72975

... More
code364 - Supply erection, testing, commissioning of Cassette type split Air conditioners suitable for operation on single/three phase AC supply, hermetically sealed compressor with air cooled condenser motor capacitor start, capacitors run relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit-4.0 TR Cassette 3 Ph

10

141255

1412550

... More
code365 - Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type

10

4981

49810

... More
code366 - Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3core 80 stand copper wiring between indoor and outdoorunit Leak testing oil and gas charging for additional piping-Cassette

250

1763

440750

... More
code367 - Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3core 80 stand copper wiring between indoor and outdoorunit Leak testing oil and gas charging for additional piping4C x 4 sqmm Copper flexible cable

300

158

47400

... More
code368 - Supplying and installation of -5KVA offline UPS

1

38661

38661

... More
code369 - Supplying and installation of -12V , 200 AH Capacity Acid Battery

2

15783

31566

... More
code370 - Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. andfixing using invetred wood plugs in Case of RCC ceiling and RCC wall /stone structure or rawl plug incase of brick walls and cement plastering the damaged portion using heavy guage saddles in an intervel of 700 mm using NF Screws-\19/20mm Dia 2mm Thick

200

68

13600

... More
code371 - Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. andfixing using invetred wood plugs in Case of RCC ceiling and RCC wall /stone structure or rawl plug incase of brick walls and cement plastering the damaged portion using heavy guage saddles in an intervel of 700 mm using NF Screws-25mm dia 2mm Thick

100

80

8000

... More
code372 - Supplying and drawing pvc insulated gas injected physical foam jelly filled co axial TV Cable Rg6

200

42

8400

... More
code373 - Supply & Fixing of 4 Pair Telephone wire

200

33

6600

... More
code374 - Supplying & drawing UTP Cat 6 E Lan Cable

400

34

13600

... More
code375 - Supply & Fixing of Single I/0

10

405

4050

... More
code376 - Supply & Fixing of Double I/O

15

727

10905

... More
code377 - Supply & Fixing of T.V telephone Socket

20

147

2940

... More
code378 - Supply & Fixing of 12U with 800 mm depth

1

9271

9271

... More
code379 - Supplying & Fixing of power Strip

1

1233

1233

... More
code380 - Supply & Fixing of 24 port 10 / 100 /1000 Switch

1

8241

8241

... More
code381 - Supply & Fixing of 1 Mtr patch cable

15

190

2850

... More
code382 - Supply & Fixing of 2 Mtr patch cable

15

286

4290

... More
code383 - Supply & Fixing of 24 port 10 / 100 patch panel

1

4258

4258

... More
code384 - Fabricating, supplying and erection of ...Mtrs long hot dip Galvanized Octagonal pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47m/sec for …….Mtrs pole in single section and single joint welded as per IS 9595/IS 10178AWS having dimensions bottom …..mm, top….mm with 3/4mm thick, suitable base plate and 4Nos of ..... long J bolts along with template and the pole shall be galvanized with not less than 65micron etc as per ASTM-A 123 and 153 etc., (excluding foundation) as per drawing appended. a)3 Meters-Top 70mm and bottom 130mm dia

4

5671

22684

... More
code385 - Fabricating, supplying and erection of ...Mtrs long hot dip Galvanized Octagonal pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47m/sec for …….Mtrs pole in single section and single joint welded as per IS 9595/IS 10178AWS having dimensions bottom …..mm, top….mm with 3/4mm thick, suitable base plate and 4Nos of ..... long J bolts along with template and the pole shall be galvanized with not less than 65micron etc as per ASTM-A 123 and 153 etc., (excluding foundation) as per drawing appended. b)5 Meters-Top 70mm and bottom 130mm dia

4

8871

35484

... More
code386 - Supplying and fixing Led Street Light70 watts

8

5955

47640

... More
code387 - Supplying and fixing 4C x 16sq.mm. Al. Alum. Cable

150

150

22500

... More
code388 - Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., complete

120

102

12240

... More
code389 - Labour charges for laying of 1.1 KV class UG cable when supplied agency in existing trench GI pipe / stoneware pipe / on wall / on pole as required.(69/5) - In exixting trench/duct. 6sqmm to 16 sqmm

150

11

1770

... More
code390 - Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable (Sl no 7.10 page no 62)

150

100

15000

... More
code391 - Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 Sqmm

26

12

323.44

... More
code392 - Supplying and fixing 25mm Dia

100

80

8000

... More
code393 - Supplying and fixing 70 Watt Led Flood light

4

7390

29560

... More
code394 - Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to table 3 class 5 of IS:8130- 1984 and (Virgin) PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 & confirming to GTP of GROUP-A-4C x 2.5 sqmm

200

141

28200

... More
code395 - Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting -6Way TP &N

1

3735

3735

... More
code396 - Supplying fixing & wiring earth leakage miniature circuit breaker (ELMCB) 240 / 450 V up to 300mA sensitivity on Existing / panel Board-16 - 25 Amps 2 pole

3

2536

7608

... More
code397 - Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898-5 - 32 Amp SP

4

523

2092

... More
code398 - Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898-40 - 63 Amps SP

4

726

2904

... More
code399 - Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898-8W 0.5 Mtr Height Bollard Light

8

3391

27128

... More
code400 - Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898-LED Post Top Lantern with 25 Watt

5

7173

35865

... More
code401 - Supply, installation, testing and commisioning of Flush mount model chairman unit with gooseneck mic with ring LED and intreconnection cable and out socket for linking next units with talk and priority switch with delegate inter face unit aliminum/ PVC Housing

1

34800

34800

... More
code402 - Supply, installation, testing and commisioning of Flush mount model delegate unit with gooseneck mic with ring LED and intreconnection cable and out socket for linking next units with talk and priority switch with delegate inter face unit aliminum/ PVC Housing

1

32800

32800

... More
code403 - Supply, installation, testing and commisioning of Table top model chairman unit with gooseneck mic with ring LED and intreconnection cable and out socket for linking next units with talk and priority switch with delegate inter face unit aliminum/ PVC Housing and Headphone socket

1

12400

12400

... More
code404 - Supply, installation, testing and commisioning of Table top model delegate unit with gooseneck mic with ring LED and intreconnection cable and out socket for linking next units with talk and priority switch with delegate inter face unit aliminum/ PVC Housing and Headphone socket

1

12400

12400

... More
code405 - Supply, installation, testing and commisioning of controller unit with 1 mic input 1aux PA out, rack mountable can handle up to 50 to 300 delegate units with expansion options

1

174000

174000

... More
code406 - Supply, installation, testing and commisioning of controller unit with 1 mic input 1aux PA out, rack mountable can handle up to 60 delegate units with expansion options

55

103

5665

... More
code407 - Supply, installation, testing and commisioning of 9 core multistrand high gain low cable with required end connectors 10 meter to connect between the delegate units and controller including charges for labour, lead and lifts, loading and unloading

5

220

1100

... More
code408 - Supply, installation, testing and commisioning of compact ceiling speaker with Back Can Power handling up to 6 watt RMS/watt/100volt @ 1456 ohms single channel selectable taping 5'' LF driver and tweeter

10

1450

14500

... More
code409 - Supplying, installing and commissioning of CCTV Surveillance System.-CCTV Surveillance Cameras-Indoor Dome IR Camera, HD Video

12

6900

82800

... More
code410 - Outdoor Bullet- 25 Mtrs Range, HD Video

2

7500

15000

... More
code411 - Power Supply 12VDC, Each Supports upto 5 IR Cameras

5

3300

16500

... More
code412 - 16 Channel DVR, HD, with 2TB Surveillance HDD

1

57000

57000

... More
code413 - 19 Color Monitor For DVR

1

10440

10440

... More
code414 - CCTV Cabling including PVC Conduit

700

114

79800

... More
code415 - Supplying , Errection , Testing and Commissioning of Diesel Generator Set on existing CC platform comprising of Diesel Engine developing -----BHP @1500 RPM confirming to BS 5514-62.5 KVA /50 KW

1

618585

618585

... More
code416 - Supply , Erection , Testing and commissioning of AMF Panel suitable for DG Set-up to 62.5 KVA

1

75900

75900

... More
code417 - SUMP TANK-Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m-

47.8

114

5460.672

... More
code418 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates-

3.88

6992

27129.5808

... More
code419 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.-

2.3

297

685.216

... More
code420 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- FOOTING

3.39

8277

28060.0131

... More
code421 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- RCC WALL

6.59

13029

85861.5713

... More
code422 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- SLAB

2.75

11496

31614.66

... More
code423 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.9, Page No.42, Volume-2.

80.2

371

29821.568

... More
code424 - KSRB 12-6.2: Providing 20mm round M.S. footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6

10

286

2867.2

... More
code425 - Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) SL.NO-11.32, PG.NO-84, VOLUME-II.

1.27

88492

112385.2464

... More
code426 - SEPTIK TANK-Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m-

47.8

114

5460.672

... More
code427 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates. sl.no-2.1.2, pg.no-15. volume-1

3.88

6992

27129.5808

... More
code428 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.-

2.3

297

685.216

... More
code429 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- FOOTING

3.39

8277

28060.0131

... More
code430 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- RCC WALL

9

13029

117261.63

... More
code431 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- SLAB

2.75

11496

31614.66

... More
code432 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.9, Page No.42, Volume-2.

83.3

371

30974.272

... More
code433 - KSRB 12-6.2: Providing 20mm round M.S. footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6

10

286

2867.2

... More
code434 - Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) SL.NO-11.32, PG.NO-84, VOLUME-II.

1.51

88492

133623.4032

... More
code435 - BOREWELL-Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1)       Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a)     Above 20 M and upto 30 M - 15%, b)     Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2)   A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test etc. complete

2

5922

11845.12

... More
code436 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)-Borewell depth of 0 to 50 Mtrs

50

414

20720

... More
code437 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)-Borewell depth of 50 to 100 Mtrs

50

519

25984

... More
code438 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)Borewell depth of 100 to 150 Mtrs

50

552

27608

... More
code439 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)-Borewell depth of 150 to 200 Mtrs

25

640

16016

... More
code440 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)--Borewell depth of 200 to 250 Mtrs

60

751

45091.2

... More
code441 - Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc. complete-5.00 HP/3.7KW-50 STG

1

33208

33208

... More
code442 - Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments-1x3x6 Sqm.

168

207

34809.6

... More
code443 - Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments-Size 65 mm

4

1736

6944

... More
code444 - Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete.-3 to 6 HP pumps

1

11760

11760

... More
code445 - Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments

125

616

77000

... More
code446 - Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets.

1

616

616

... More
code447 - Supply and delivery at site Accessories for Single Phase pumpset like SS Groove Nipples,SS Studs & Nuts,Screw Clips &water proof Insulation Tape etc complete with ISI mark

1

5040

5040

... More
code448 - Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work.

1

1512

1512

... More
code449 - Labour charges for providing connection using insulated sheathed steel wire cable as per IS 1554/ 1988 with latest amendments from KPTCL pole to meter board unit, with all necessary materials ,tools and equipments,as per specificationswith testing of as per instructions of engineer incharge of work- 3.5 x 10 sqmm

168

218

36691.2

... More
code450 - Earthing: Providing and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia.

1

4200

4200

... More
code451 - Providing and fixing suitable for 1.1 KV class UG cable filled with necessary bitumen/insulating compound complete with terminals, clamps,bolts,nuts and washers etc. with necessary materials and labour tools and equipments as per instructions of engineer incharge of work.-3.5x10 Sqm

1

504

504

... More
code452 - Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments.-5 HP, size 50x40 Head 46M, Discharge 174 LPM

1

29587

29587.04

... More
code453 - NON SR RATES-Providing and fixing Aluminium fixtures like aldrops of size 300x16mm,tower bolts of size 200 x 12mm, latches of size 250x12mm, 100mm length oxidized iron hinges,handles of size 150mm, door stoper and door brush of approved make and quality including cost oof conveyance of all meterials and as per the direction of EIC of work with all lead and lift and as directed by the engineer in charge of works.Single shutter

3

4434

13302

... More
code454 - Providing and fixing sash mortise lock body with cylinder outside key and inside knob suitable for flush doors including cost of materials labours etc,. Complete as per specifications

3

2150

6450

... More
code455 - Providing supplying and fixing ss satin finish barrel bolt/aldrop-300mm for door shutters including cost of materials,labour etc., complete as per specifications.,

6

575

3450

... More
code456 - Providing supplying and fixing floor mounted door stopper suitable for flush door shutters including cost of materials,labour etc., complete as per specifications.,

6

550

3300

... More
code457 - Providing supplying and fixing ss door handle set (22mm dia 300mm long ) including cost of materials,labour etc., complete as per specifications.,

6

1550

9300

... More
code458 - Providing supplying and fixing Hydraulic door closures with mounting heavy duty shuitable for flush door shutters including cost of materials,labour etc., complete as per specifications.,

20

1350

27000

... More
code459 - Providing supplying and fixing SS but hinges for fixing door shutter to frame for flush door shutters including cost of materials,labour etc., complete as per specifications.,

30

375

11250

... More
code460 - Providing supplying and fixing SS screws-25mm for fixing door shutter to frame for flush door shutters including cost of materials,labour etc., complete as per specifications.,

180

4

720

... More
code461 - Providing supplying and fixing MS Holdfast of size 260mm x 25mm x 5mm thk for fixing door frames to walls, including cost of materials cutting masonry pockets for receiving ms holdfasts one coat of shop primer,concrete filling of pockets,desposal of debries, including cost of materials,labour etc., complete as per specifications.,

24

45

1080

... More
code462 - Supplying, installing, testing and commissioning approved make15 mm CP health faucet of approved make with necessary CP flexible hose 1.0m long nozzle, CP crutch,nozzle anguler stop cock with wall flange etc., complete.make: Jaguar,modle no. ALD-573

15

1307

19605

... More
code463 - Supplying, installing and testing Soap Dish including necessary fixing materials etc., complete. (Jal,Jaquar or equivalent)

25

126

3150

... More
code464 - Forming horizontal or vertical grooves on uniform size 10 mm wide and 7 mm deep at junction of wall and column / beam and finishing the grooves to elevation etc, including cost of materials , labour flor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incindental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge.per the instructions of the Engineer in charge. (All floors)-Front side Elevation

1300

31

40300

... More
code465 - Forming horizontal or vertical grooves on uniform size 10 mm wide and 7 mm deep at junction of wall and column / beam and finishing the grooves to elevation etc, including cost of materials , labour flor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incindental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge.per the instructions of the Engineer in charge. (All floors)-Front side Elevation

300

31

9300

... More
code466 - Forming horizontal or vertical grooves on uniform size 10 mm wide and 7 mm deep at junction of wall and column / beam and finishing the grooves to elevation etc, including cost of materials , labour flor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incindental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge.per the instructions of the Engineer in charge. (All floors)-top parapet wall

600

31

18600

... More
code467 - MOULDING : Providing 200 mm height architectural moulding with three stepswith 50mm on top and bottom and 100 mm middle champhered steps in standard architectural methods of execution running on thre edge of the slab, canopy and other places as shown in the drawings or as per the instructions given. the rate includes, materials, labour and complete.-elevation slope

300

1800

540000

... More
code468 - Supplying fixing,testing, and commisioning of solar water heating system suitable/designed for "forced circulation" with solar panels hot water storage tank with supporting brackets etc complete. The solar water heater shall consists of the following Capacity : 200 LPD SS body solar panel with copper collectors SS body Bottom insulation of solar panel with 100 microns laminated with rock wool of 48kg/cum density Support structure made out of polyster powder coated CR tubes 1 No. Air release/vaccum release safty valve with a ball valve of 20mm dia. Uniform out put on continous usage. intel and outlet provision. Necessary interconnecting piping between panel to staorage tank etc.

1

78000

78000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.