Karnataka Housing Board Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Karnataka Housing Board - KHB Tender

Works
Civil And Construction
Building Construction
Opening Date16 Jan 2025
Closing Date17 Feb 2025
Tender Amount₹ 6,52,87,479.99 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

500

168

84000

... More
code05 - Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water, all materials, usage & all other appurtenances required to complete the work.

3965.36

497

1973559.672

... More
code06 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates.

235.56

5947

1400922.432

... More
code07 - Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.

1107.47

123

137215.533

... More
code08 - Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. Addition for Formwork, centering and Scaffolding. (The cost of steel reinforcement to be paid separately) RCC Column Footing M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.

437.16

7185

3141003.3432

... More
code09 - Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. Addition for Formwork, centering and Scaffolding. (The cost of steel reinforcement to be paid separately) RCC Pedestal walls M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.

15.89

11309

179712.0864

... More
code10 - Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. Addition for Formwork, centering and Scaffolding. (The cost of steel reinforcement to be paid separately) RCC Retaining walls M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.

70.63

11309

798808.3488

... More
code11 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & dowel bars to be paid separately) This rate also includes formwork. RCC Column M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. GROUND FLOOR

98.93

11309

1118874.5568

... More
code12 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & dowel bars to be paid separately) This rate also includes formwork. RCC Column M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. FIRST FLOOR

33.29

11422

380267.0094

... More
code13 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & dowel bars to be paid separately) This rate also includes formwork. RCC Column M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. SECOND FLOOR

12.63

11537

145713.4467

... More
code14 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & dowel bars to be paid separately) This rate also includes formwork. RCC Plinth Beam M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.

63.6

9038

574875.948

... More
code15 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & dowel bars to be paid separately) This rate also includes formwork. RCC Lintel M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. GROUND FLOOR

16.92

11496

194516.3808

... More
code16 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & dowel bars to be paid separately) This rate also includes formwork. RCC Lintel M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. FIRST FLOOR

11.34

11611

131671.008

... More
code17 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & dowel bars to be paid separately) This rate also includes formwork. RCC Lintel M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. SECOND FLOOR

2.46

11727

28849.1826

... More
code18 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & dowel bars to be paid separately) This rate also includes formwork. RCC Roof Beam M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. GROUND FLOOR

59.09

11496

679312.8216

... More
code19 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & dowel bars to be paid separately) This rate also includes formwork. RCC Roof Beam M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. FIRST FLOOR

25.02

11611

290512.224

... More
code20 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & dowel bars to be paid separately) This rate also includes formwork. RCC Roof Beam M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. SECOND FLOOR

4.97

11727

58284.7307

... More
code21 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & dowel bars to be paid separately) This rate also includes formwork. RCC Roof Slab M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. GROUND FLOOR

195.46

10777

2106615.1058

... More
code22 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & dowel bars to be paid separately) This rate also includes formwork. RCC Roof Slab M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. FIRST FLOOR

102.18

10885

1112280.39

... More
code23 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & dowel bars to be paid separately) This rate also includes formwork. RCC Roof Slab M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. SECOND FLOOR

24.02

10994

264084.5272

... More
code24 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & dowel bars to be paid separately) This rate also includes formwork. RCC Plain Chajja M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. GROUND FLOOR

180.36

10418

1879075.2492

... More
code25 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & dowel bars to be paid separately) This rate also includes formwork. RCC Plain Chajja M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. FIRST FLOOR

133.56

10522

1405405.134

... More
code26 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & dowel bars to be paid separately) This rate also includes formwork. RCC Plain Chajja M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. SECOND FLOOR

49.8

10627

529268.424

... More
code27 - FLAGGING CONCRETE - Providing and laying Cement concrete flooring 40 mm thick with 20 mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete. All-round the building

158

473

74820.9

... More
code28 - Supplying, fitting and placing TMT FE550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Ground Floor

99391.6

93

9335852.988

... More
code29 - Supplying, fitting and placing TMT FE550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. First Floor

28014.25

94

2657711.8975

... More
code30 - Supplying, fitting and placing TMT FE550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Second Floor

7547.89

95

723238.8198

... More
code31 - Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Ground Floor

154.44

8376

1293728.436

... More
code32 - Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. First Floor

87.16

8451

736599.6192

... More
code33 - Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Second Floor

31.13

8535

265714.4732

... More
code34 - Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Ground Floor

58.47

1084

63419.4855

... More
code35 - Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. First Floor

66.48

1095

72828.84

... More
code36 - Providing and laying autoclaved aerated cement blocks masonry with 200 mm thick AAC blocks as per IS 2185 (Part III) in super structure above plinth level up to floor I level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Ground Floor

73.32

8376

614194.308

... More
code37 - Providing and laying autoclaved aerated cement blocks masonry with 200 mm thick AAC blocks as per IS 2185 (Part III) in super structure above plinth level up to floor I level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. First Floor

46.06

8460

389698.4602

... More
code38 - Providing and laying autoclaved aerated cement blocks masonry with 200 mm thick AAC blocks as per IS 2185 (Part III) in super structure above plinth level up to floor I level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Second floor

27.21

8545

232517.0688

... More
code39 - Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.

95

1066

101346

... More
code40 - Providing Salwood frames for doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. Ground Floor

0.83

103755

86117.2725

... More
code41 - Providing Salwood frames for doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. First Floor

0.69

104793

72307.3839

... More
code42 - Providing Salwood frames for doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. Second Floor

0.14

105841

14817.7736

... More
code43 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame all-round door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification. Ground Floor

52.37

4245

222318.5055

... More
code44 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame all-round door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification. First Floor

34.02

4287

145864.152

... More
code45 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame all-round door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification. Second Floor

6.72

4330

29100.8256

... More
code46 - Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In Charge. (Fixtures shall be paid for separately) Ground floor

60

737

44226

... More
code47 - Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In Charge. (Fixtures shall be paid for separately) First floor

49

744

36479.03

... More
code48 - Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) Ground floor

19.74

2142

42283.08

... More
code49 - Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) First floor

19.74

2163

42705.9108

... More
code50 - Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Ground Floor

100

6878

687855

... More
code51 - Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) First Floor

71.2

6947

494650.608

... More
code52 - Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Second Floor

14.4

7016

101042.064

... More
code53 - Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Ground floor

756

147

111132

... More
code54 - Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. First floor

504

148

74828.88

... More
code55 - Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Second floor

50.4

149

7557.48

... More
code56 - Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. Ground Floor

30.15

1622

48910.8375

... More
code57 - Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. First Floor

93.03

1638

152426.8641

... More
code58 - Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. Second Floor

9.9

1654

16383.114

... More
code59 - Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Ground Floor

418.57

2189

916354.3725

... More
code60 - Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. First Floor

146.15

2211

323158.111

... More
code61 - Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Second Floor

123

2233

274689.75

... More
code62 - Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Ground Floor

501.8

1202

603289.05

... More
code63 - Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. First Floor

517.28

1214

628117.5856

... More
code64 - Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Second Floor

39

1226

47830.38

... More
code65 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. Ground Floor

59.52

943

56183.904

... More
code66 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. First floor

59.52

953

56745.7728

... More
code67 - Providing skirting, dado, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with while cement slurry over rough plaster surface (excluding cost of rough plastered surface which should be measured and paid separately) using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications and direction of Engineer in charge. Size 15x15cms. Ground Floor

138.15

1521

210188.3175

... More
code68 - Providing skirting, dado, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with while cement slurry over rough plaster surface (excluding cost of rough plastered surface which should be measured and paid separately) using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications and direction of Engineer in charge. Size 15x15cms. First floor

126.75

1536

194771.655

... More
code69 - Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. INTERNAL PLASTERING GROUND FLOOR

2308.14

267

618004.485

... More
code70 - Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. INTERNAL PLASTERING FIRST FLOOR

1846.84

270

499440.9412

... More
code71 - Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. INTERNAL PLASTERING SECOND FLOOR

226.04

273

61738.3052

... More
code72 - Providing 15 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. EXTERNAL PLASTERING GROUND FLOOR

1375.37

309

426020.8575

... More
code73 - Providing 15 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. EXTERNAL PLASTERING FIRST FLOOR

1092.34

312

341738.569

... More
code74 - Providing 15 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. EXTERNAL PLASTERING SECOND FLOOR

571.8

315

180677.364

... More
code75 - Providing 6 mm cement plaster with cement mortar 1:3 (1 cement: 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FOR CEILING GROUND FLOOR

1020.97

221

226195.9035

... More
code76 - Providing 6 mm cement plaster with cement mortar 1:3 (1 cement: 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FOR CEILING FIRST FLOOR

753.22

223

168548.0394

... More
code77 - Providing 6 mm cement plaster with cement mortar 1:3 (1 cement: 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FOR CEILING SECOND FLOOR

238.15

226

53821.9

... More
code78 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. GROUND FLOOR

3908.36

105

410377.8

... More
code79 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. FIRST FLOOR

3185.83

106

337857.2715

... More
code80 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. SECOND FLOOR

709.57

107

76002.0427

... More
code81 - Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Interior walls and Ceiling Ground floor

3908.36

165

648396.924

... More
code82 - Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Interior walls and Ceiling First floor

3185.83

167

533817.6748

... More
code83 - Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Interior walls and Ceiling Second floor

709.57

169

120080.5311

... More
code84 - Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Ground floor

1375.37

182

251280.099

... More
code85 - Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. First floor

1092.34

184

201569.5002

... More
code86 - Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Second floor

571.8

186

106566.366

... More
code87 - Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Ground floor

71.88

165

11924.892

... More
code88 - Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. First floor

20.79

167

3483.5724

... More
code89 - Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Second floor

27.72

169

4691.0556

... More
code90 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. Ground floor

1656.6

192

318315.69

... More
code91 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. First floor

1656.6

194

321496.362

... More
code92 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. Second floor

792

196

155239.92

... More
code93 - Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Ground floor

75.3

145

10990.035

... More
code94 - Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. First floor

82.5

147

12161.325

... More
code95 - Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Second floor

36

148

5359.68

... More
code96 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Ground floor

270

593

160177.5

... More
code97 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. First floor

270

599

161778.6

... More
code98 - Providing and fixing in position collapsible steel shutters with single or double leaf with vertical channel 20mmx10mmx2mm braced with iron flat iron diagonals 20mmx5mm size, with top and bottom rails of T iron sections of 40x40x6 mm with 38mm dia steel pulleys complete with bolts and nuts, locking arrangements, stoppers, handles on both sides with 7.5cms openings at 10 cms c to c applying a priming coat of red lead paint, cost of materials, labour, HOM of machinery complete as per specifications.

6.3

8689

54745.74

... More
code99 - Providing & fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter.

80

305

24444

... More
code100 - Weathering course to roofs using Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates. First Floor

65.46

6724

440166.132

... More
code101 - Weathering course to roofs using Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates. Second floor

48.2

6725

324157.05

... More
code102 - Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. First Floor Roof

65.46

857

56154.861

... More
code103 - Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. Second floor Floor Roof

48.2

866

41761.926

... More
code104 - Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof including cost of material, labour, scaffolding etc as per specifications and as per directions of the Engineer-in-Charge.

114

1370

156208.5

... More
code105 - Providing and fixing plaster mesh 200mm wide manufactured out of hot dipped galvanized iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications.

300

46

13860

... More
code106 - Providing and fixing oxidised M.S. double acting spring hinges with necessary screws etc. complete. 150mm.

285

319

90972

... More
code107 - Providing and fixing chromium plated brass 100 mm mortise latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.

95

1159

110124

... More
code108 - Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete.

95

136

12967.5

... More
code109 - Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.

65

126

8190

... More
code110 - Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 8 mm thickness (weight not less than 20 kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications.

84

1370

115101

... More
code111 - Providing and fixing anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868. Minimum anodic coating of grade AC 15) sub frame work for windows and ventilators with extruded built up standard tubular sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia and size (Dash fastener to be paid for separately) including cost of materials, labour, usage charges of machinery complete as per specifications.

625

414

259218.75

... More
code112 - WATER SUPPLY - Earth work excavation for pipelines/cables by mechanical means upto 600mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. All Kind of soils. Depth upto 1.50m

270

275

74277

... More
code113 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete. Ground Floor 15 mm nominal dia Pipes

60

42

2520

... More
code114 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete. Ground Floor PVC pipes 25mm dia, 10 kg/sqcm & class 5

150

50

7560

... More
code115 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete. Ground Floor PVC pipes 32mm dia, 10 kg/sqcm & class 5

150

70

10552.5

... More
code116 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete. Ground Floor PVC pipes 50mm dia, 10 kg/sqcm & class 5

150

106

15907.5

... More
code117 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete. First Floor 15 mm nominal dia Pipes

30

191

5733

... More
code118 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete. First Floor PVC pipes 25mm dia, 10 kg/sqcm & class 5

150

333

50085

... More
code119 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete. First Floor PVC pipes 32mm dia, 10 kg/sqcm & class 5

200

420

84000

... More
code120 - Providing GM (copper alloy) wheel valves/ check valve confirming to IS 778/1990 Class-I with latest amendments No. 1 and with ISI mark screwed in bonnet integral seat inside, screw, rising spindle screwed female ends confirming to IS 554/ 1990 body hydraulically tested 1.50 HP seat hydraulically tested 1.00 HP. For 32 mm dia GM (Copper alloy) wheel valves/ check valve.

6

1404

8429.4

... More
code121 - Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 50 mm dia GM (Copper alloy) Gate valves

6

1345

8070.3

... More
code122 - Providing and fixing PTMT pillar cock of approved quality and colour. 15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 gms.

30

329

9891

... More
code123 - Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fttings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests.

10

5128

51282

... More
code124 - Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid.

6

6275

37655.1

... More
code125 - Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern. One urinal basin with 5 litre white P.V.C. automatic flushing cistern

4

4676

18706.8

... More
code126 - Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Angle back wash basin size 600 x 480 mm with single 15mm C.P. brass pillar tap.

12

2689

32268.6

... More
code127 - Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete.

30

256

7686

... More
code128 - Providing and fixing PVC (S.W.R) Gully Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete

10

363

3633

... More
code129 - Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.

10

520

5208

... More
code130 - Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

10

1281

12810

... More
code131 - Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 75mm dia

200

257

51450

... More
code132 - Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.

20

152

3045

... More
code133 - Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support tank.

10000

9

94500

... More
code134 - UGD - Earth work excavation for pipeline trenches in all kinds of by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of slumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata. Ordinary/soft rock (without requiring blasting) Depth upto 1.50 m

162

275

44566.2

... More
code135 - Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes all-round to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: HDPE Grade PE80-PN6.0, 75mm dia

50

257

12862.5

... More
code136 - Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes all-round to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: HDPE Grade PE80-PN6.0,110mm dia

300

492

147735

... More
code137 - Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes all-round to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: HDPE Grade PE80-PN6.0, 160mm dia

300

1006

302085

... More
code138 - Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.

17

4447

75612.6

... More
code139 - Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..

9

5726

51540.3

... More
code140 - Providing and constructing “WIRE CUT BRICK MACHINEHOLE CHAMBERS” using Portland/Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber. Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Supplying and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Supplying and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de-watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm diaCirc. B M.H: Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.0 M depth & SFRC cover & frame.

1

25566

25566.45

... More
code141 - SUMP TANK - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth

12

107

1285.2

... More
code142 - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Depth exceeding 3m, but not exceeding 6m

36

122

4422.6

... More
code143 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

20.87

279

5828.991

... More
code144 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates

3.31

6288

20814.7695

... More
code145 - Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Floor slab

3.85

6639

25560.7275

... More
code146 - Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Additionalities for Formwork, Centering & Scaffolding - Earth Retaining Structures. For RCC walls

8.6

7303

62806.402

... More
code147 - Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Additionalities for Formwork, Centering & Scaffolding - Earth Retaining Structures. For Covering slab

2.41

9958

24000.5393

... More
code148 - Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members wherever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)

1125.94

93

105759.5442

... More
code149 - Providing 20 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) fnished with a floating coat of neat cement to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifcations and as per directions of Engineer-in-charge.

70.49

450

31752.2205

... More
code150 - Providing and fxing MS ladder between landings, 45 cms wide using angle iron of specifed sizes, 20mm MS bars at 25 cms. centre to centre, with necessary supports of same angle iron etc. as directed, including hand railing on both sides with 25mm dia. GI pipes with angle iron props at 2 mtrs. intervals and 0.5M heigh, including fxing in ground with CC 1:2:4 and two coats of anticorrosive bituminous paint etc. with all lead and lifts etc. complete with: MS angle 65x65x8mm.

1.8

4595

8272.53

... More
code151 - Providing and fxing MS inspection door of size 60 cms x 60 cms, including MS frame made of 50x50x6mm angle, shutters made of 3mm thick MS sheets, with hinges, locking arrangements at top etc. including painting with anticorrosive approved paint etc. complete including all lead and lifts etc.

2

2247

4494

... More
code152 - COMPOUND WALL - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifcations, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. All kinds of soil 95%

71.76

76

5500.404

... More
code153 - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifcations, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Soft Rock 5% (without blasting)

71.76

285

20494.656

... More
code154 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (Vol.1, P6, I 1.9)

143.52

168

24111.36

... More
code155 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M5) Using 40 mm nominal size graded crushed coarse aggregates.

12.39

6288

77913.8955

... More
code156 - Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)

49.93

6708

334952.9085

... More
code157 - Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticizers laid in fnished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement to be paid separately) Rate includes Formwork, Centering and Scaffolding.M25 Design Mix Using 25 mm nominal size graded crushed coarse aggregates.

6.75

7185

48498.885

... More
code158 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & dowel bars to be paid separately) Rate includes Formwork, Centering and Scafolding. RCC Column M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.

5.4

12214

65959.704

... More
code159 - Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement to be paid separately) Rate includesr Formwork, Centering and Scafolding. RCC Plinth Beam M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates

17.52

10777

188825.8296

... More
code160 - Providing Thermo-Mechanically Treated bars of grade Fe-500 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members wherever necessary complete as per Design including cost of material, labour, usage charges complete as per specifcations. (The laps and wastages shall not be measured separately)

5844.84

93

549005.8212

... More
code161 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifcations.

262.8

1375

361481.4

... More
code162 - Providing 15 mm cement plaster of mix :1:4 (1 cement: 4 fne sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifcations and as per directions of Engineer-in-charge.

936

309

289926

... More
code163 - Finishing walls with water proofng cement paint of required shade:Old work (one coats applied @ 2.20 kg/10 m²) over priming coat of primer applied @ 0.80 litrs/10 m² complete including cost of Priming coat including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifcations and as per directions of Engineer-in-charge.

936

91

85503.6

... More
code164 - BOREWELL - Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fxing Casing pipes beyond 20 M (for fxing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fxed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test..

1

5398

5398.05

... More
code165 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the fnal depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) Upto 50 Mtrs

25

364

9108.75

... More
code166 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the fnal depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) Above 50 Mtrs and upto 100 Mtr.

50

464

23205

... More
code167 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the fnal depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) Above100 Mtrs. and upto 150 Mtr.

50

478

23940

... More
code168 - Supply of ISI mark 175mm nominal bore, plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fxed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty.

25

2029

50741.25

... More
code169 - Supply and delivery of galvanized mild steel tubes of 6mtr standard length heavy duty (C Class) as per IS 1239 (Part-I) 1990 with latest amendments with ISI Mark (one end fitted with Heavy Duty collar and other end fitted with protective cover) 65mm

15

3753

56306.25

... More
code170 - Providing, supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confrming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifcations,as per necessary ammendments and instructions of engineer incharge of work. 7.50 HP - 90 LPM @ 165 m = 15 STG Outlet Dia - 2.00"

1

46212

46212.6

... More
code171 - Providing and fxing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments.

1

157

157.5

... More
code172 - Providing and laying at site of work MS casing caps as per IS 1239 (part II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fxing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge.

1

172

172.2

... More
code173 - Supply and delivery at site wrought middle steel (galvanized) GI union confrming to IS 1239-II, 1991 with latest amendments if any. For 50 mm dia GI Union.

1

229

229.95

... More
code174 - Providing and construction of platform in CC 1:2:4 proportion using hard granite or basalt or trap jelly of 20mm and down size for India MarkII hand pump as per approved drawing enclosed to the S.R (UNICEF standard), including machine mixing, laying, tamping, curing and smooth finishing of exposed faces in CM 1:3 with necessary moulds, including earth work excavation with all leads of materials etc. complete.

1

4113

4113.9

... More
code175 - Supplying of Thermosetting Plastic i.e., Fiber Glass reinforced polyster sheet moulding compound(SMC) pump house with SMC door & canopy etc..., component as directed by the departmental offers.

1

13702

13702.5

... More
code176 - Supply and delivery at site of brand new best make pressure gauge bourdon type of size 63mm as per IS 778/1984 with ISI Mark and as per its latest amendments.

1

472

472.5

... More
code177 - Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x10 m2

182.88

304

55686.96

... More
code178 - Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG

30000

-

12000

... More
code179 - Supply, installing, testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type.

1

14962

14962.5

... More
code180 - Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specifcation, with testing of as per instructions of engineer incharge of work.

1

1312

1312.5

... More
code181 - Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box. per 3 poles

1

1312

1312.5

... More
code182 - Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. 32Amps

1

2041

2041.2

... More
code183 - Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrifcation and commissioning of the same at the location of respective pump sets.

1

577

577.5

... More
code184 - BOREWELL TO SUMP - Earth work excavation for pipelines/cables by mechanical means upto 600mm trench width, as per drawing and technical specifcations, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.

108

203

21999.6

... More
code185 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

108

279

30164.4

... More
code186 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete. PVC pipes 50mm dia, 10 kg/sqcm & class 5

100

106

10605

... More
code187 - Providing and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of Ductile Iron (DI) conforming ti IS-1865 with the latest amendments and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 with the latest amendments only. The stem sealing should be with toroidal sealing rings (minimum 2 " O " rings). Body and bonnet should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. For PN-10: (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) etc. complete. sluice Valve of PN - 10.0 and 50mm

2

5811

11623.5

... More
code188 - Providing and fixing of Single/ Double chamber triple function tamper proof (Both the orifces to be housed in the single chamber) Air valves with Body and cover in Ductile cast iron of grade GGG 40/ 50. All internal parts such as float, shell with appurtenances., all cover bolts of austenitic alloy / SS 304 steel, DN 50 float of HOSTAFLON / SS 304 and gaskers and seals of EPDM. Epoxy powder coating (EP-P) inside and outside colour blue RAL5005. The valves should be designed for all the three functions i.e., 1. Large orifice for venting of large air volumes on start up. 2. Large orifice for intake of large air volumes. 3. Small orifice for discharge of pressurized air during operation. For PN10.0 etc. complete. For TP Air Valves of 80mm dia

2

29600

59201.1

... More
code189 - Providing and fxing gun metal non- return valve of approved quality (screwed end) : 50 mm nominal bore.

2

1429

2858.1

... More
code190 - BOREWELL ELECTRICAL - Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confrming to ISI standards and its latest amendments. 5 HP, size 80x65 Head 23.50M, Discharge 600 LPM

1

22500

22500

... More
code191 - Supplying of LT UG cable having aluminum conductor PVC insulated, sheathed,galvanised, steel wire/steel tap armoured cable with PVC outer sheathing 1.1 KV class. I Class 'A' PVC Cable. 4 core 10 sqmm

80

118

9504

... More
code192 - Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 10 sqmm

1

7

7.65

... More
code193 - Supplying and fixing of heavy duty cable glands suitable or UG cable 1.1KV class (metal only) 25mm dia

1

86

86

... More
code194 - Supplying……amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/ERP/DMC insulator which are mounted on powder coated 40x6 mm M.S flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc, complete. 100Amps 4x30x6mm Aluminum Strips

1

2214

2214

... More
code195 - Supplying and fixing Moulded Case Circuit breakers (MCCB) over the existing wood/panel board using necessary screws,bolts,nuts and wiring complete. Protection of Overload and short circuit with thermal Magnetic/Micro processed release and Earth Fault as per IS- 13947.(Icu =Ics) (34/9) FOUR POLE 125- 160Amps 25KA

1

8586

8586

... More
code196 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and wiring complete as required. 40-A TPN

1

1936

1936

... More
code197 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and wiring complete as required. 6-32Amps DP

1

1103

1103

... More
code198 - Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/manual reset facility suitable to mount on DN rail/flush mounting on panel board.

1

8316

8316

... More
code199 - Supplying push button operated direct online starter with an anti weld silver cadmium oxide conductor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet or iron clad enclosure and fixing the same to suitable capacity wires for 400/440 volts 3 phase motor/single phase motor upto 5 HP.

1

1490

1490

... More
code200 - Supplying, fixing and wiring 3 phase Digital Ammmeter/Voltmeter

1

1280

1280

... More
code201 - Supplying, fixing and wiring electronic 10 to 40Amps three phase 4 wire class-1 Accuracy Energy Meter.

1

5125

5125

... More
code202 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230v A.C.50Hz 12/24v D.C.

1

464

464

... More
code203 - Supplying & fixing of Caution / Danger name board as per drawing

1

163

163

... More
code204 - Fabricating supplying and mounting MS box made out 16 SWG suitable for floor/wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. 14SWG

9500

-

4085

... More
code205 - Fabricating supplying and mounting MS box made out 16 SWG suitable for floor/wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. 16SWG

13500

-

5130

... More
code206 - Fabricating supplying and mounting MS box made out 16 SWG suitable for floor/wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. Copper strip 8SWG

15

107

1615.5

... More
code207 - Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 15mm alround the cable.

15

103

1545

... More
code208 - Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.

15

78

1170

... More
code209 - Gun metal non return valve 50mm nominal bore vertical type

1

1219

1219

... More
code210 - Gun metal non return valve 65mm nominal bore vertical type

1

1945

1945

... More
code211 - FIRE & CCTV - Supply and installation of 2kg Fire Extinguisher Mono Ammonium Phosphate Powder50, Stored Pressure Type, Pressure Gauge, Gross Weight 3.6Kg, empty weight 1.6Kg, Can Height 344MM, Diameter 108MM, Discharge Time less than8 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 2meters, applicable on ClassA ,8, Candel ectrically started Fire, A Rating1A, 8Rating88 , Canconstruction: Deepdrawn&Co. ,Migwelded, valve Construciton :Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of an: Epoxy PoIyster power coating, Sheet metal thickness: 1.60MM, 5years Warranty with instalert system with uperior quality EPDM Rubber Hose pipe etc., including cost cost of supporting materials like MS stand & accessaries if it is fixingn floor/ MS brackets & accessories if it is fixing on wall,,labour,usage charges of machinery complete as per specifications. complete. IS 15683, CE A 5 with-Providing ABC Powder based MAP 50, 2Kg

15

2205

33075

... More
code212 - Supplying of four bucket stand along with buckets. Complete

10

1942

19425

... More
code213 - Supplying of FIRST AID CHART with lamination. Complete

10

420

4200

... More
code214 - Supplying and installation of RUBBERMAT 1mtrx1mtr-1Omm thick.complete including cost of materials,labour,usage charges of machinery complete as per specifications.

10

1995

19950

... More
code215 - Smart Surveillance System (CCTV): using PTZ & Fixed cameras, OFC monitoring system, HMI etc., as per specification CODE 8525 34.

1

70719

70719.6

... More
code216 - FURNITURE - Providing and fabricating cabin table with 19mm ply finished with 4mm thk approved veneer melamine finished. table top: 40mm thick table top to be formed out 2 Layers of 19mm thk ply and to be finished with 4mm thk approved venner and melamine polished. the edge of the table to be provided with approved timber beeding to from 50mm thick fascia formed to shape. finished with approved melamine polish to match the veneer. the top of the house cable trough/cable pop up box for cable management with 19mm thk ply openable as per details, complete as per details dwg. base: the base of the table shall consist of 19,, commercial ply boxing finished with 4mm thk veneer of approved amke and shade. cost to include providing and fixing 6x6mm thk aluminium beading, complete as per the drawings and instructions of the engineer-in-charge.(MR-rate excluding GST)

4

123000

492000

... More
code217 - CABIN TABLES - TYPE-1:Table Dimension: (1800x 900 x 750mm) + (1350mm x 800mm x 750mm) L shaped : Providing and Fabricating Cabin Table with 19mm ply Finished with 4mm thk Approved Veneer Melamine finished. Table top: 40mm thick table top to be formed out 2 layers of 19mm tk ply and to be finished with 4mm thk approved Veneer and melamine polished. The edge of the table to be provided with approved timber beading to form 50mm thick fascia formed to shape Finished with approved Melamine polish to match the veneer. The top to house cable trough / cable pop up box for cable management with 19mm thk ply openable as per details, complete as per detail dwg.Base: The base of the table shall consist of 19mm commercial ply boxing finished with 4mm thk veneer of approved make & shade. Cost to include providing & fixing 6x6mm thk Aluminium beading, complete as per the drawing & instructions of the Engineer-in-charge.

25

16703

417585

... More
code218 - Conference table : providing and fixing of conference table with 8 seater of size ( 1200mm x 3000mm x 750mm). Consisting of 25mm thick PLPB table top edge bounded, 18mm thick PLPB with edge bounded modesty, hardware minifix assembly and screw leg, as per specifications, drawings and as directed by ingneer incharge 4800mm x 2400 x 750mm Ht u shaped with a top width of 600mm ( MR-rate excluding GST)

1

123000

123000

... More
code219 - Executive chair: supplying and placing in position high back chair with following specification. Seat: seat to be formed out of bent ply/pvc backing with deformable pre moulded foam upholstered with approved fabric. Back rest: the high back rest in leatherette over frame. the back rest to have provision of heigh adjustable backrest for an optimum adustment of the lumber support, to be either by turning knob or push button. upholstered with leatherette. high bach chair to have head rest. mechanism: synchronises knee-tilt with 2 way locking mechanism.gas lift: synchronised gas lift. arm rest: adjustable arm rest to be formed out of pu foam/pvc with fixed arm. base: base shall consist of 5 prong formed of die cast aluminium with chrome plated. casters: twin wheel high resistant polyamide castors.( MR - Rate exculding GST)

1

50000

50000

... More
code220 - Supplying and placing in position high back chair with following specification. Seat: deat to be formed out of bent ply/pvc backing with deformable pre moulded foam upholstered with approved fabric. Back rest: the high back rest in leatherette over frame. the back rest to have provision of height adjustable backrest for an optimum adjustment of the lumber support, to be either by turning knob or oush botton. upholstered with leatherette. high back chair to have head rest. mechanism: synchronised knee-tilt with 2 way locking mechanism. gas lift: synchronised gas lift. arm rest: adjustable arm rest to be formed out of PUfoam/pvc with fixed arm. base: base shall consist of 5 prong formed of die cast aluminium with chrome plated. casters: twin wheel high resistant polyamide castors.( MR- rate excluding GST)

5

40000

200000

... More
code221 - MEDIUM BACK CHAIR-FABRIC WITH CASTORS, supply and placing in posistion medium back chairs with following specifications. Seat: seat to be formed out bent ply/pvc backing with deofrmable pre moluded foam uphpstered with approved fabric. Back rest: the medium back rest in fabric over frame. the back rest to have provision of height adjustalblebackrest for an optimum adjustment of lumbar support, to be either by turning knob or push button. upholstered with mesh fabric. mechanism: synchronised knee-tilt with 2way locking mechanism. gas lift: synchronised gas lift. arm rest: adjustable arm rest to be formed out of pu foam/pvc with provision of height swinging adjsutable, width adjsutable, height dustments, base: base shall consist of 5 prong formed of die cast aluminium with chrome plated finished with soft-dual wheel casters. casters: twin wheel high resistant polyamide castors - revolving char ( MR- rate excluding GST)

9

15000

135000

... More
code222 - MEDIUM BACK CHAIR-FABRIC WITH CASTORS, supply and placing in posistion medium back chairs with following specifications. Seat: seat to be formed out bent ply/pvc backing with deofrmable pre moluded foam uphpstered with approved fabric. Back rest: the medium back rest in fabric over frame. the back rest to have provision of height adjustalble backrest for an optimum adjustment of lumbar support, to be either by turning knob or push button. upholstered with mesh fabric. mechanism: synchronised knee-tilt with 2way locking mechanism. gas lift: synchronised gas lift. arm rest: adjustable arm rest to be formed out of pu foam/pvc with provision of height swinging adjsutable, width adjsutable, height dustments, base: base shall consist of 5 prong formed of die cast aluminium with chrome plated finished with soft-dual wheel casters. casters: twin wheel high resistant polyamide castors - non revolving and non - tilting chair ( MR- rate excluding GST)

38

10000

380000

... More
code223 - Manufacturing, supplying and fixing wooden wardrobe of 0.6m deep using 19mm thick vinyl bonded water proof black board, shutters all round ward robe, lockable drawers with sliding channels, cupboard drapery hangers, curtain rods with end brackets, openable shutters with 19mmx600 thick plain teak wood beading, lipping 1.5mm thick commercial ply vertical support 1mm lamination sheet of approved colour, shade and quality on all exposed surfaces. inner surface painted with 2 coats of white synthetic enamel paint over 2 coats of patti, one coat of wood primer, including coat of brass fittings parliametary hinged, c handles, tower bolts, magnetic catches, approved brand lock, adhesives, synthetic resins, nails, screws etc., complete including cost of all materials, labour charges, complete as per specifications ( MR- rate excluding GST)

5.4

10000

54000

... More
code224 - Tahashildar chamber back storage ( 6600mmx600mmx1000mm) same as wooden wardrobe material specification ( MR- rate excluding GST)

4.32

10000

43200

... More
code225 - Side table: supply, installation and fixing of cabinets made up of waterproof ply, 600mm deep with 1mm thick internal laminate and shutters finished with 1mm thick external laminate as per the designers ( MR- rate excluding GST)

10

9000

90000

... More
code226 - Providing and supplying Kitchen cabinet with 19mm thick one side Architect recommended decorative Acrylic Glossy or Matt finished laminate (1.5mm thick) and other side balancing lamination(preferably white) on factory pressed bwp grade marine ply as per IS 710 of approved brand . complete as per direction of engineer in-charge.

1.89

3100

5859

... More
code227 - Providing and fixing Three seater Sofa with cushion of size 7(L)x2.5(W) X2.75(H) ft made of upholstery fabric with seats fitted with padding, springs, webbing and as per direction of engineer in charge.

2

37500

75000

... More
code228 - Providing and fixing Two seater Sofa with cushion of size 5(L)x2.5(W) X2.75(H) ft made of upholstery fabric with seats fitted with padding, springs, webbing and as per direction of engineer in charge.

3

24000

72000

... More
code229 - Providing and fixing Single seater Sofa with cushion of size 3(L)x2.5(W) X2.75(H) ft made of upholstery fabric with seats fitted with padding, springs, webbing and as per direction of engineer in charge.

4

17000

68000

... More
code230 - Providing & fixing of Tea table 900mm x 750mm 450mm with 12mm thick ethched tempered glass with bevelled drawing made out of BWP ply and out faces laminated with 4mm thick veneer or 1mm thick laminate.

5

7500

37500

... More
code231 - DRAINS & CULVERTS - Earthwork excavation for foundation of buildings, 1.5m and above in width, in Hard soil not exceeding 1.5m in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50m.after breaking of clods complete as per specifications and direction of Engineer incharge.

9

107

963.9

... More
code232 - Earthwork excavation for foundation (in deposited soil) and filling sides of foundation upto plinth in layers not exceeding 20 cms in depth, compacting each deposited layers by ramming after watering with lead upto 50m and lift upto 1.5m. complete as per specifications and direction of Engineer in charge.

2.7

497

1343.79

... More
code233 - Providing and laying in position plain cement concrete of mix 1:4:8 with OPC cement @ 220kgs, with 20mm and down size graded granite metal coarse aggregates @ 0.84cum and fine aggregates @ 0.56cum machine mixed, concrete laid in layers not exceeding 15cms, thick, well compacted, in foundation and plinth, including cost of all materials, labour, HOM of machinery, curing complete as per specifications.

1.35

5947

8028.72

... More
code234 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & dowel bars to be paid separately) Rate includes Formwork, centering and Scaffolding. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.

6.66

10644

70892.2368

... More
code235 - Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge..

21.6

221

4785.48

... More
code236 - Supplying, fitting and placing TMT FE550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.

470.03

93

44149.9179

... More
code237 - RAINWATER HARVESTING - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. Hard soil 50%

14.4

107

1542.24

... More
code238 - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. Soft Rock 50% (without blasting)

14.4

381

5488.56

... More
code239 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates.

0.86

5947

5114.592

... More
code240 - Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work

8.83

8367

73884.5835

... More
code241 - Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

27

1052

28406.7

... More
code242 - STP - Waste Water Treatment by Prefabricated anaerobic Bio Septic tank : (For 100 Souls/10KLD) Providing, installation and commissioning of an anaerobic Bio Septic tank with all necessary accessories such as pre-filter, pipes, prefabricated RCC Tank (including internal matrix for enhanced growth of Bacteria), Anaerobic microbial Inoculum developed by DRDO and baffle wall to control the flow of water and to increase the retention time in the RCC Tank (Note: Refer to technical specification attached as Annexure-1) including cost of material, loading and unloading and as directed by the Engineer in charge etc., complete, including annual maintenance of the system for 5 years.

1

945000

945000

... More
code243 - NON-SR ITEMS - Providing supplying and fixing Hydraulic door closures with mounting heavy duty shuitable for flush door shutters including cost of materials,labour etc., complete as per specifications.,

10

1350

13500

... More
code244 - Supplying, installing, testing and commissioning approved make15 mm CP health faucet of approved make with necessary CP flexible hose 1.0m long nozzle, CP crutch,nozzle anguler stop cock with wall flange etc., complete.make: Jaguar,modle no. ALD-573

15

1307

19605

... More
code245 - MOULDING : Providing 200 mm height architectural moulding with three stepswith 50mm on top and bottom and 100 mm middle champhered steps in standard architectural methods of execution running on thre edge of the slab, canopy and other places as shown in the drawings or as per the instructions given. the rate includes, materials, labour and complete.

300

1800

540000

... More
code246 - Providing Teak wood frames of doors, windows, clerestory windows,ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.

0.36

235649

84833.64

... More
code247 - Providing and fixing in position fully panelled Teak wood shutters for doors with , stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures)

5.76

9479

54599.04

... More
code248 - Providing and fixing MS door of Godrej make for strong room door class 1 with BIS labelled +CG with vemtilator ( TRTL 15X6, FR30) (Excluding frame; 1060mmx2045mm, including frame 1200mmx2100mm

1

656000

656000

... More
code249 - PARKING STAND - Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.-By Mechanical Means using Dozer-In area of thorny jungle.

0.6

508

304.92

... More
code250 - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m. HARD SOIL

11.23

107

1202.733

... More
code251 - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m. SOFT ROCK

1.25

381

476.4375

... More
code252 - Earth work excavation by manual means for drains,canals, waste weir,draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading,caution lights, removal of stumps and other deleterious matter,excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m.

1.28

254

325.248

... More
code253 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates.

34.95

6555

229102.4925

... More
code254 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

20.46

279

5714.478

... More
code255 - Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work.

1.25

89

111.5625

... More
code256 - Providing and fixing ion wall face unplasticised Rigid PVC rain water pipes confirming to IS :13592 Type A,including jointing with seal ring confirming to IS:5382,leaving 10mm gap for thermal expansion,(i) Single socketed pipes 100mm diameter.

50

307

15382.5

... More
code257 - Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.

1056

157

166320

... More
code258 - Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

65

596

38766

... More
code259 - Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :.

6

446

2677.5

... More
code260 - Gutter (600 mm over all girth)

20

1127

22554

... More
code261 - Ridges plain (500 - 600mm)

10

473

4735.5

... More
code262 - Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.

60

840

50400

... More
code263 - LIFT - 6 PASSANGER - Design,supplying,erecting testing and commissioning of-Passenger /Bed -cum-passenger hospital lift with speed of 1mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415V 3phase 50cycles ACsupply ,powder coated/Stainless Steel car entrance doors enclosure swith suitable colour vinyl flooring, LED carillumination, emergency light, intercom and fan as desired by the user,central opening/ side opening door with or without attendant operation,7segment display buttons,call register indicator, fire man drive, SS handrails inside car, full length infrared curtain in cardoor, automatic rescue device with batteries, voice announcing inr egional /international languages ,Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, ounter weight etc., The total product and services shall adhere to IS14665/2016 (with latest amendments)part/section1 to with regards to general guidelines of fire safety rated doors ,MRLL beams, pressure switch, manual change over for doors during emergency, ARD of 10times with sufficient battery back up and standard dimensions of chair car and door openings for all sizes and capacities of lifts including fitness certificate and duly observing all other safety norms prescribed and adhere to CPWD specifications, PCB Norms, National Electricity Code (NEC), NBC-2016, IEC and Karnataka State Lifts, Escalators and Passengers Conveyers Act 2012 and Rules 2014. The Supplier shall be registered in Government Electrical Inspectorate in the State of Karnataka.

1

1444050

1444050.3

... More
code264 - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m.

7.14

107

764.694

... More
code265 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates.

1.79

6288

11256.3255

... More
code266 - Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)

6.12

6708

41055.714

... More
code267 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates.

0.68

6555

4457.502

... More
code268 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

3.09

279

863.037

... More
code269 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.

11.88

309

3679.83

... More
code270 - Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 (1 cement : 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete.

13.72

3526

48389.754

... More
code271 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.

35

593

20763.75

... More
code272 - INTERNAL ELECTRIFICATION - PVC CONDUITS AND ACCESSORIES - SUB MAIN CIRCUIT / CIRCUIT MAINS Wiring for lighting/Power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper With Low conductor resistance single core wire in open or conceanled system of wiring with specified IS-694:1990 (a) 3/0.028 (3/22) mm (1.5 Sqmm Copper wire)

2000

26

52000

... More
code273 - b) 3/0.036 (3/20) mm (2.5 Sqmm Copper wire)

4000

42

168000

... More
code274 - c) 7/0.036 (7/20) (4 Sqmm copper wire)

3000

63

189000

... More
code275 - d)7/0.048 (7/18) mm (6 Sqmm Copper wire)

300

92

27600

... More
code276 - Open Conduit System Supplying heavy gauge PVC conduit pipe …….dia confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using NF screws (a)19/20 mm dia 2 mm thick.

250

69

17250

... More
code277 - b)25 mm dia 2mm thick.

75

81

6075

... More
code278 - c) 32 mm dia 2.5 mm thick.

75

106

7950

... More
code279 - Concealed Conduit System Supplying heavy PVC condiuit pipe ……mm dia ......mm thick confirming to IS 2509 woth suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/1.2) (a) 19 / 20 mm dia 2 mm thick

50

66

3300

... More
code280 - b)25 mm dia 2 mm thick

1500

78

117000

... More
code281 - c)32 mm dia 2.5 mm thick

150

103

15450

... More
code282 - Groove Cutting Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, up to wall surface complete ( 3/1.7) (a)up to 50mm conduit in brick wall

150

29

4350

... More
code283 - Supplying and fixing PVC/Metal conduit accessories.(3/5) (a) 19/20mm deep junction box

10

49

490

... More
code284 - Supplying and fixing PVC/Metal conduit accessories.(3/5) (b) 25mm deep junction box

10

56

560

... More
code285 - Supplying and fixing PVC/Metal conduit accessories.(3/5) (b) 32mm deep junction box

10

61

610

... More
code286 - Supplyind and Fixing Metal Fan Box with Round Hook.(11/32)

100

117

11700

... More
code287 - Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using copper PVC insulated multi strand 2x1.5Sqmm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. (a) Short point up to 3Mtr from tapping point to out let via switch box

20

269

5380

... More
code288 - b) Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch box

60

379

22740

... More
code289 - c) Long point above 6Mtr up to 10Mtr from tapping point to out let via switch box

150

555

83250

... More
code290 - d) Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches

50

677

33850

... More
code291 - e) Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches box

25

989

24725

... More
code292 - Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293. (16/3.7) (a) 6 Amp one way

120

102

12240

... More
code293 - b) 6 Amp two way

4

166

664

... More
code294 - c) 6 Amps 3 way socket.

200

171

34200

... More
code295 - d) Stepped fan regulators

100

276

27600

... More
code296 - e) 6 Amp bell push

10

177

1770

... More
code297 - f) 6/16 A universal switch & socket

10

2136

21360

... More
code298 - g) TV Socket

5

156

780

... More
code299 - g) Telephone Socket

40

156

6240

... More
code300 - h) RJ45 / I.O.outlet

50

337

16850

... More
code301 - i) 16 Amp one way

100

180

18000

... More
code302 - Supplying and flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (7/16) (a) 1-2 Way

25

138

3450

... More
code303 - b) 4-5 Way

40

177

7080

... More
code304 - c) 6 Way

40

220

8800

... More
code305 - d) 8 Way

10

261

2610

... More
code306 - e) 10-12 Way

3

319

957

... More
code307 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.(7/17) (a) 1 to 2 Module

20

137

2740

... More
code308 - b) 3 Moudule

40

161

6440

... More
code309 - c) 6 Moudule

40

234

9360

... More
code310 - d) 8 Moudule

8

284

2272

... More
code311 - e) 10-12 Moudule

10

344

3440

... More
code312 - f) 16 Moudule

10

397

3970

... More
code313 - Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB ). The entire plug and socket shall b mounted in a themoplastic/powder coated metal box & wired Completely. (57/6.44) 20 Amps SP & N

1

971

971

... More
code314 - Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB ). The entire plug and socket shall b mounted in a themoplastic/powder coated metal box & wired Completely. (57/6.44) 30 Amps TP & N

1

1700

1700

... More
code315 - A. L.T.SWITCHGEAR AND DISTRUBUTION BOARDS - L.T.PANEL, SMSB-1, 2, EX LTG PANEL AND DISTRIBUTION BOARDS. - Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. (P-41&42/38-b) 16SWG

15400

-

6622

... More
code316 - Supplying of on load change over over switches 4 poles, AC 23Amps duty 415V, 50HZ, AC Supply. 400Amps 4P COS

1

29105

29105

... More
code317 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Microprocessed release and Earth Fault as per IS-13947. ( Icu = Ics) Group-A THREE POLE 320-400Amps 35kA.4P, 35kA

1

30111

30111

... More
code318 - 125-Amps 25kA.TP

2

8598

17196

... More
code319 - 160Amps 25kA.TP

2

11050

22100

... More
code320 - 100Amps 25kA TP

2

6086

12172

... More
code321 - Supplying and fixing of Shunt trip suitable for MCCB.CBCT.(P-36/10)

2

1703

3406

... More
code322 - Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50Hz AC with latest micro controller based,digital readout of percentage leakage current, programmable delay/ auto/manual reset facility suitable tomounton DIN rail/ flush mounting on panel board.

3

9255

27765

... More
code323 - Supplying, fixing and wiring 3 Phase Digital Ammeter /Voltmeter.(P-48/6.27)

3

1425

4275

... More
code324 - Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy. Group 'A' (P-40/29)

1

9315

9315

... More
code325 - Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer.class 0.5 accurecy with Tape Wound.(P-40/30)

7

562

3934

... More
code326 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C.Group 'A' (P-40/34)

5

515

2575

... More
code327 - Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which aremounted on powder coated 40x6mmM.S.flat framework inexistingpanel board.Thebusbar shall havesuitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 400Amps 4x50x10mm Alluminium Strips

1

4445

4445

... More
code328 - 100Amps 4x30x6mm Alluminium Strips

2

2465

4930

... More
code329 - 250Amps 4x30x10mm Alluminium Strips

1

3435

3435

... More
code330 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75x75x6mm

5

555

2775

... More
code331 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint 75x150x75X6mm

2

926

1852

... More
code332 - ACCP PANEL (50 KVAR) - Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. 16SWG

600

-

258

... More
code333 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Microprocessed release and Earth Fault as per IS-13947. ( Icu = Ics) Group-A (P-34&35/9) THREE POLE 125Amps 25kA.TP

1

8598

8598

... More
code334 - Supplying and fixing of Shunt trip suitable for MCCB.CBCT.(P-36/10)

1

1703

1703

... More
code335 - Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. Group 'A' (P47/15)

1

9255

9255

... More
code336 - Supplying, fixing and wiring 3 Phase Digital Ammeter /Voltmeter.(P-48/6.27)

1

1425

1425

... More
code337 - Supplying, fixingandwiring50/5 to400/5A5VAburdenCurrent Transformer Class 0.5 accuracy with Tape Wound.

2

562

1124

... More
code338 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C.Group 'A' (P-40/34)

2

515

1030

... More
code339 - Fixing a shunt capacitor of … KVAR capacity with necessary clamps, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor a) up to 5 KVAR

2

154

308

... More
code340 - b) 6 to 10 KVAR

2

214

428

... More
code341 - b) 11 to 20 KVAR

2

344

688

... More
code342 - Supplying, fixing and wiring Automatic Power Factor controller fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three place LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect / disconnect banks, with automatic recognition or with standard programs.(56/6.36)

1

21640

21640

... More
code343 - Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic alluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary botls,nuts and washers etc., complete. 250Amps 4x30x10mm Alluminium Strips

2

3435

6870

... More
code344 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75x75x6mm

1.5

555

832.5

... More
code345 - MCB Distribution Board Supplying and fixing regular MCB Distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG M.S enclosure. I - Double Door a) 4Way SP &N

3

1524

4572

... More
code346 - b) 12Way SP &N

1

2329

2329

... More
code347 - a) 4Way TP &N

1

4038

4038

... More
code348 - b) 6Way TP &N

3

4940

14820

... More
code349 - Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board.(Residual current circuit board))(RCCB) a) 16-25 Amps 2 pole (2 Module type)

2

4277

8554

... More
code350 - b) 32-40 Amps 2 pole (2 Module type)

2

4559

9118

... More
code351 - c) 25-40 Amps 4 pole

2

5147

10294

... More
code352 - Supplying and fixing of MINIATURE CIRCUIT BREAKERS in existing distribution boards using necessary fixng materials and "C" type Curve, Indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 SP 6-32Amps

50

415

20750

... More
code353 - DP 6-32Amps

4

739

2956

... More
code354 - TPN 6-32Amps

1

1717

1717

... More
code355 - TPN 40-63Amps

8

3088

24704

... More
code356 - LT CABLES Supplying of 1.1 KV LT UG cable having aluminium conductor PVC insulated, extruded inner sheathed, galvanised, steel strip (except 2Cx 10Sq.mm wire armoured ) Confirming to IS-3975:1990 ( No. of Strip indicated in GTP) & extruded PVC outer sheated armoured cable with specified IS-1554 Part-1:1998 & confirming to the attached GTP of GROUP-A. (62/7.4) 3 1/2 C - 240 Sq.mm A2XFY

100

445

44500

... More
code357 - 3 1/2 C - 50 Sq.mm A2XFY

50

265

13250

... More
code358 - 3 1/2 C - 35 Sq.mm A2XFY

35

204

7140

... More
code359 - 3 1/2 C - 25 Sq.mm A2XFY

40

165

6624

... More
code360 - 4 C - 16 Sq.mm A2XFY

25

140

3510

... More
code361 - 4 C - 10 Sq.mm A2XFY

25

118

2970

... More
code362 - END TERMINATION Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (69/7.14) Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. (70/7.21) 3 1/2 C - 240 Sq.mm A2XFY

2

2180

4360

... More
code363 - 3 1/2 C - 50 Sq.mm

1

336

336

... More
code364 - 3 1/2 C - 35 Sq.mm

10

229

2290

... More
code365 - 4 C - 16 Sq.mm

8

131

1048

... More
code366 - 4 C - 10 Sq.mm

10

117

1170

... More
code367 - LAYING CHARGES FOR CABLES Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required. In existing trench/duct. (68/7.8) 6 sqmm to 16 sqmm

56

10

604.8

... More
code368 - 25 sqmm to 75 sqmm

81

16

1312.2

... More
code369 - 95sqmm 150Sqmm

100

42

4240

... More
code370 - PERFORATED TYPE CABLE TRAY Suplying and fixing 2mm thick perforated cable tray with powder coated paint on existing MS angle support using necessary GI bolts/nuts and washer or welding as required.( 63 / 7.19) 150 mm x 50mm

10

440

4400

... More
code371 - SUPPLY OF LIGHT FIXTURES. Supplying CFL mirror light fitting with 2x11W CFL lamp, choke, Perspex cover and completely wired for use on 230V 50Hz AC (25/4.25)

10

648

6480

... More
code372 - Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.1X4'-w 20/22 w

150

690

103500

... More
code373 - Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. 1X4'36/40 w

150

1269

190350

... More
code374 - Supplying of recessed/surface mount aesthetic Square / rectangular modular luminary made out of single piece powder coated CRCA sheet steel accommodating all electrical accessories like elecronic ballast suitable to operate on 230V 50Hz AC supply with 18Watts PLL-compact fluorescent lamp, pre-wired up to terminal block with bright anodized aluminum reflector & P5 paralite louvers with spring loaded plastic toggles. (25/4.20) 1x18Watts

2

1724

3448

... More
code375 - Supplying of recessed/surface mount aesthetic Square / rectangular modular luminary made out of single piece powder coated CRCA sheet steel accommodating all electrical accessories like elecronic ballast suitable to operate on 230V 50Hz AC supply with 18Watts PLL-compact fluorescent lamp, pre-wired up to terminal block with bright anodized aluminum reflector & P5 paralite louvers with spring loaded plastic toggles. (25/4.20) 2x18Watts

2

1939

3878

... More
code376 - SupplyingandfixingofLEDBulkheadof10WwithIP65protection and IK08 impact resistance suitable for surfaceandwallmounting applications.

8

842

6736

... More
code377 - Supply of LED Streetlight luminaire with pressure diecast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising ofanti glare clear diffuser with Injectio nmoulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @Lumen Maintenance of 70%, maximum lightintensity should be between 60 degrees to 70 degrees. CCTGreater than5500K, IP66 optical and electrical compartment &impact resistanceof complete luminaire Greater than IK08. Power Factor Greater than0.9 withmains, Surge Protection-Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of40mm to 50mm.Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60 Hz application. Compliance to IS 10322/IEC 60598,LM79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........WSystem Power consumption. LED EfficiencyGreater than1301m/w, nominal CRI Greater than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO9001:2008. Housingwith supplier wordmark/name shall be Engraved /Embossing on thediecast housing/ Bodypart.Warrantyof2Years again stany manufacturing defect working understand ard electrica lconditions as mentioned above should be given by LED manufacturer &Cree/Nichia/ Lumileds/Osram make LED Source. LED street light 40W

2

4024

8048

... More
code378 - Fabricating, supplying and errecting swaged tubular pole of height …Mtr having three sections, and providing two coats of redoxide paint and finished with two coats of enamelled paint of approved quality and colour and M.S. base plate of suitable size welded at the bottom of the pole(ass per IS) and 40mm dia GI / flexible PVC pipe of 1 mtr length fitted to the heavy guage polycorbonate control box including 5way connector of size 167x125x82mm for 7.5M pole/200x160x98mm for remaining length of pole with front opening cover, with locking arrangements and suitable capacity MCB / DP switch, The pole shall be errected in cement concrete work (1:2:4) including excavation and refilling of planting depth of the pole to the ground level and the coping CC shall be up to 0.6M above ground level as per IS 2713 - 7. (40/5.13) a) Erection of heavy duty pole on Footpath/ median b) 9Mt (5Mt Hb,165.1mm dia 4.85mm thick x2M Hm, 139.7mm dia 4.50mm thick x 2M Ht,114.3mm dia 3.65mm thick) as per IS 410 SP 32.

3

15500

46500

... More
code379 - Supplying and fixing of solar lux level street light control switch single phase including suitable capacity contactor. 3kv

3

10097

30291

... More
code380 - Supplying of Ceiling Fan with Capacitor ratingAsper guidelineof BEE5star ratingandIS:374/19andalsocomplywithIS:1709/1984 withlatestamend ment,Ratedvoltage220V/50Hz,Ratedpowerupto 35W+/-10%,RatedcurrentAsper IS:374/19,Ratedpower factor 0.9lagging(min),Ratedspeed350+/-10%RPM,Ratedairdelivery 210+/-10%CubicMeterMinimum,Ratedservicevalue6.2CMM/ W,ThreeBladesofbladeleaf1.05mmthickAluminiumAlloysheet, Class Bmotor insulation, Bearing Two ball bearings, Top 6202, Bottom6201,asperISspecification,Motorwinding.TempriseShall notexceed75degCoverandambientof400Cbyresistancemethod at245V,InsulationresistanceShallnotbelessthanTwoMegaOhms (2MOhms), Leakage current Should not exceed 210MicroAmp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019with latest amendment, 2year manufacturerWarranty. (BLDC fans) 6.4.1 48" Sweep 5 Star (1200 mm)

100

2677

267700

... More
code381 - SUPPLY OF EXHAUST FAN Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50HZ, AC Supply complete.(84/9.2) (a) 12" sweep (300mm)

10

2969

29690

... More
code382 - FIXING OF EXHAUST FAN Fixing on e exhaust fan in the nitch already left in the wall with bolts and nuts and 5 amps. Ceiling rose wisth sufficient length of 23/0.0076 inch PVC insulated twincore wire. (115/17.12)

17

412

7004

... More
code383 - FIXING OF CEILING FAN Extra length of GI pipe of class B 19mm dia for down rod. (109 / 17.10)

20

164

3280

... More
code384 - SUPPLY OF WALL FAN Supplying wall mounting fan suitable to operate at single-phase 230 V A.C. supply,(84/9.4) 400mm Sweep

40

3212

128480

... More
code385 - NETWORKING AND TELECOMMUNICATION Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable.. Two Pair (Tag block to outlet).

150

21

3150

... More
code386 - Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable.. 5 Pair

10

46

460

... More
code387 - Supply and fixing 20 pair telephone tag block "Krone make".

2

1500

3000

... More
code388 - Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-oxial TV cable. RG-6.

10

40

400

... More
code389 - Supplying and drawing UTP-CAT 6E LAN cable.

1500

38

57000

... More
code390 - Supplying & Fixing of switch mounting rack with power manager & Cable manager . . 18U with 650mm depth

3

28396

85188

... More
code391 - Supplying & Fixing of switch mounting rack with power manager & Cable manager . .(85 / 11.4) Supplying & Fixing of Power strip

3

1457

4371

... More
code392 - Supplying & Fixing of switch mounting rack with power manager & Cable manager . . Supplying of shelf

1

827

827

... More
code393 - Supplying & Fixing of switch mounting rack with power manager & Cable manager . . Supplying & fixing of Castor wheels to the Shelf. (set of 4)

6

1582

9492

... More
code394 - Supplying & Fixing of switch mounting rack with power manager & Cable manager . .

2

1209

2418

... More
code395 - Supplying fixing of Network Switches. 24 port 10/100/1000 Switch

1

7415

7415

... More
code396 - Supplying & fixing of I/O socket eith back box Single I/o

1

490

490

... More
code397 - Supplying & fixing of I/O socket eith back box Double I/o

10

550

5500

... More
code398 - Supplying & Fixing of …mtrs Cat6 Patch Cable 1mtr

50

224

11200

... More
code399 - Supplying & Fixing of Patch panel for Lan cabling 24 Port 10/100 patch panel

1

4100

4100

... More
code400 - UPS & ACCESSORIES Supplying, erection, testing and commissioning of Off-Line UPS system suitable for operation on 230 V, 50Hz, A/C supply, with all accessories complete and Excluding batteries and wiring complete. a) 5KVA Off Line UPS Two Hour back up Excluding 6 x 150Ah batteries

1

39898

39898

... More
code401 - AH Batteries Supplying, installation, testing & commissioning of 12 Volts DC, AH Batteries in poly propylene container for U.P.S. Low maintenance Tubular batteries a) 6 x 12 V, 150 AH capacity Acid Battery

2

28187

56374

... More
code402 - EXTERNAL ELECTRIFICATION - Providing 2 pole structure at the tapping point. (2 nos) - Material cost - RCC D.P structure using 9 mtrs RCC Pole with WL 145 kg

2

20928

41856

... More
code403 - 45 kN Disc Insulators

12

510

6120

... More
code404 - Guy Set Complete

4

742

2968

... More
code405 - Spiral Earth Electrodes

4

239

956

... More
code406 - Concrete for Guy set (without cement)

4

158

632

... More
code407 - Caution / Danger Board

2

150

300

... More
code408 - Anti - Climbing Device (12mtrs / 1 kg G.I. Barbed Wire) Lumpsum

4

89

356

... More
code409 - 11 kV 400 A D/B GOS

2

18634

37268

... More
code410 - H-Frame for mounting GOS

2

4332

8664

... More
code411 - Concreting of 9Mts RCC Poles - Base Concreting in CC 1:4:8 500x650x150mm

4

229

916

... More
code412 - Pole Concreting in CC 1:2:4 650x500x1700mm

4

2566

10264

... More
code413 - Coping in CC 1:2:4 and as per actuals

4

444

1776

... More
code414 - Earthing of DP set with GI Pipe

4

1277

5108

... More
code415 - Lighting arestors metal oxide 9 Kv, 5Kv

2

2070

4140

... More
code416 - Painting of 9Mts RCC Poles

4

960

3840

... More
code417 - Labour cost - RCC D.P structure using 9 mtrs RCC Pole with WL 145 kg

2

4134

8268

... More
code418 - Guy Set Complete

4

327

1308

... More
code419 - Spiral Earth Electrodes

4

93

372

... More
code420 - Caution / Danger Board

2

80

160

... More
code421 - Anti - Climbing Device (12mtrs / 1 kg G.I. Barbed Wire) Lumpsum

4

42

168

... More
code422 - 11 kV 400 A D/B GOS

2

1214

2428

... More
code423 - H-Frame for mounting GOS

2

323

646

... More
code424 - Earthing of DP set with GI Pipe

4

507

2028

... More
code425 - Lighting arestors metal oxide 9 Kv, 5Kv

2

63

126

... More
code426 - Extension of 11 KV line from the existing sub station / Feeder (1 KM) - Material cost - 9.0M Long, RCC Pole 145 kg WL (for Deadend, Anchor points.

2

7076

14152

... More
code427 - 11kv Horizontal cross arms with HT st supports bolt, nut and washers

2

487

974

... More
code428 - 45 Kn Disc Insulators

1

510

510

... More
code429 - 11 KV Pin Insulators with GI Pins

6

87

522

... More
code430 - Rabbit ACSR Conductor

0.1

46234

4623.4

... More
code431 - PG Clamp for rabbit to rabbit conductor

1

102

102

... More
code432 - Guy sets

1

742

742

... More
code433 - Concreting Materials for guy sets

1

158

158

... More
code434 - Spiral earth electrode

3

239

717

... More
code435 - Concereting of 9Mts RCC Poles - Base Concreting in CC 1:4:8 500x650x150mm

2

229

458

... More
code436 - Pole Concerecting in CC 1:2:4 500x650x1700mm

2

2566

5132

... More
code437 - Coping in CC 1:2:4 and asper actuals

2

444

888

... More
code438 - Caution / Danger Board

1

150

150

... More
code439 - Anti - Climbing Device (10mtrs / 1 kg G.I. Barbed Wire) Lumpsum

1

89

89

... More
code440 - Transportation of robit ACSCR Conductor and all other materials at 2% on material cost

1

25000

25000

... More
code441 - Labour Cost - 9.0M Long, RCC Pole 145 kg WL (for Deadend, Anchor points.

2

4134

8268

... More
code442 - 11kv Horizontal cross arms with HT st supports bolt, nut and washers

2

99

198

... More
code443 - Rabbit ACSR Conductor

0.1

2608

260.8

... More
code444 - Guy sets

1

354

354

... More
code445 - Spiral earth electrode

3

93

279

... More
code446 - Caution / Danger Board

1

80

80

... More
code447 - Anti - Climbing Device (10mtrs / 1 kg G.I. Barbed Wire) Lumpsum

1

42

42

... More
code448 - Loading & unloading of poles

1

8000

8000

... More
code449 - Erection of HT Metering Cubical - Material cost - 11KV HT Metering Panel 3CTS, 3PTS for 3poles 4 wires metering with transparent cover TTB with 3x8 mm Copper busbar (HT metering box fabricated out of 3mm MS sheet dule epoxy powder coated with out meter)

1

140585

140585

... More
code450 - Load break switch for HT metering cubicle

1

124500

124500

... More
code451 - 0.2 S class ETV meter with ABT teature and DLMS protocall with TOD foar above

1

20000

20000

... More
code452 - Earthing HT Metering cubicle with GI pipe

2

1277

2554

... More
code453 - Construction of plot form exevation of 1.5x1.5x 1 mtr pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 1cm thick layers well compacted curing etc., complete providing and construction of stone masonry 0.9 mt below ground level and 1.2mtr above ground level neatly dressed in CC 1:6 cutting completes providing painting to stone masonry in cm 1:3 after reacting joint and nicely joint and nicely laying curing etc., plastering they consider sand face in cm 1:4 including smooth rendering curing etc., caring at every no stops completely

1

25192

25192

... More
code454 - Labour cost - 11KV HT Metering Panel 3CTS, 3PTS for 3poles 4 wires metering with transparent cover TTB with 3x8 mm Copper busbar (HT metering box fabricated out of 3mm MS sheet dule epoxy powder coated with out meter)

1

1208

1208

... More
code455 - Load break switch for HT metering cubicle

1

706

706

... More
code456 - 0.2 S class ETV meter with ABT teature and DLMS protocall with TOD foar above

1

1145

1145

... More
code457 - Earthing HT Metering cubicle with GI pipe

2

573

1146

... More
code458 - TRANSFORMER - 9 mts RCC DP transformer structure using 9 mts RCC poles

1

31554

31554

... More
code459 - 11 KV, 5 KN polymetric Pinindulators (24 mm dia FRP rod)

3

205

615

... More
code460 - 11KV -45 KN polymetric insulators

3

186

558

... More
code461 - Guyset complete with 15 strain insulator and concreting materials.

4

1170

4680

... More
code462 - 11 KV/433V , 100 KVA,3 phase ,50cycles Distrubtion transformer BEE-5 star rated with oil

1

221952

221952

... More
code463 - Earthing materials pipe type for grounding

4

1729

6916

... More
code464 - caution/Danger boards

2

150

300

... More
code465 - Anticlimbing devices with barbed wire

2

89

178

... More
code466 - Concreting materials for guyset without cement.

2

250

500

... More
code467 - GI wire 8 SWG

5

75

375.2

... More
code468 - Guy wire 7/10 SWG

10

77

772.3

... More
code469 - 11 KV Lightning arrestors metal oxide 9kv , 5KA

1

4752

4752

... More
code470 - LT Distribution Box for 100KVA with MCCB

1

22686

22686

... More
code471 - LT matering Box with CTS an necessary wiring for housing ETV meter

1

5126

5126

... More
code472 - LT electronic tri-victor meter 5A class-0.5 (1.0 accuracy)

1

3396

3396

... More
code473 - 11 KV soli core type HG tuse unit (set/3 Nos)

3

1069

3207

... More
code474 - 11 KV 200 Amps single Break GOS

1

9450

9450

... More
code475 - concreting materials for mts RCC poles of DP set a) Base concreting 1:4:8 500x650 x150 mm

2

312

624

... More
code476 - Pole concreting 1:2:4,650 x 500 x1700 mm

2

3434

6868

... More
code477 - Coping in CC 1:2:4 and as per actuals 150mm alround the pole for an height of 300mm

2

312

624

... More
code478 - Painting of 9 Mts RCC DP structure poles

2

960

1920

... More
code479 - LT wiring KIT

1

10080

10080

... More
code480 - Erection of 9mts RCC DP transformer Structure

1

6983

6983

... More
code481 - Fixing of guyset

2

593

1186

... More
code482 - Erection of 100 KVA Distribution transformer

1

1590

1590

... More
code483 - Fixing earthings

4

949

3796

... More
code484 - Fixing of cauton/danger board

2

80

160

... More
code485 - Providing Anticlimbing devices

2

42

84

... More
code486 - Providing of lightning arrestors

3

119

357

... More
code487 - Fixing of LT Distribution Box

1

385

385

... More
code488 - Fixing of LT Wiring kit

1

949

949

... More
code489 - Fixing of LT matering Box

1

863

863

... More
code490 - Fixing of LT electronic tri-vector meter

1

480

480

... More
code491 - Fixing of 11 KV Soli core type HG fuse unit

3

337

1011

... More
code492 - Fixing of 200 amps/S/B GOS

1

1104

1104

... More
code493 - HT CABLE 11 KV 3 core 95 sq.mm XLPE UG Cable - Material Cost 11 kV Class 3X 95 Sq.mm XLPE UG Cable

25

548

13721.5

... More
code494 - Cable termination kit Out door HS Type Suitable for 95 Sq.mm

1

2990

2990

... More
code495 - Cable termination kit In door HS Type Suitable for 95 Sq.mm

3

2753

8259

... More
code496 - Cable covering tiles 250X125X40 mm or 125x125x40 mm

100

10

1000

... More
code497 - Sand

5

1700

8500

... More
code498 - RCC Hume pipe, 2000 mm long, 150 mm dia

6

300

1800

... More
code499 - Collars for RCC Hume pipe

4

80

320

... More
code500 - GI Pipe, 150 mm dia for drain crossing, cable raising etc.,

6

1144

6864

... More
code501 - Route and joint indicating stones

5

120

600

... More
code502 - Labour charges - Cable trench excavation, 1025x0.6x1=600, Ordinary soil

12

205

2460

... More
code503 - b) Laying of cable in trench

25

35

895

... More
code504 - c) Refilling and consolidation

12

45

540

... More
code505 - d) Making of cable terminations

4

1554

6216

... More
code506 - f) Covering the cable with tiles

12

2

31.2

... More
code507 - g) Spreading Sand and forming with Sand round the cable

25

9

228.75

... More
code508 - h) Laying of RCC Hume pipes

12

40

480

... More
code509 - i) Laying of GI Pipe

2

45

90

... More
code510 - j) Laying of Route and Joint indicating stones

5

68

340

... More
code511 - Regular Labour Charges

1

41522

41522

... More
code512 - Chain link fencing - Providing chain link fencing 50mm size o f 8 guage properly stretched between rectangular poles and fixed with suitable bolts & nuts, the free ends shall be welded to the pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction o f the engineer incharge for work including two coats of approved quality paint over one coat o f primer paint.

92.4

300

27720

... More
code513 - DIESEL GENERATOR SET Supplying, erection, testing and commissioning of… KVA Diesel Generating Set on existing CC platform Comprising of Diesel Engine Developing ….BHP @ 1500RPM confirming to BS 5514. The engine should be trubocharged, Air/water cooled with 10% over load for 1 hour in every 12 hours of operation coupled to suitable capacity alternator rated at 415V,0,8 PF(lag) 50 Hz, 3 Phase, 4 wire system, confirming to Sceenprotected, revolving field, Mounted on suitable Channel Iron Base Frame, Complete wisth suitable capacity Fuel Tank, required number of Batteries of 12/24V as per requirement, Accoustic enclosure as per CPCB Approved Norms. 62.5KVA / 50KW

1

641071

641071

... More
code514 - AMF PanelSupply, Erection, testing, and commissioning of AMF panel suitabe for…KVA DG set. The panel is of cubical type base/floor mounting control panel wisth hinged door, undrilled bottom gland plate of suitable capacity aluminium Bus Bar with accommodation for 2 pole contactor and 4 pole MCCB for alternator with thermal O/L relay, 3pole contactor and 4 pole MCCB for mains, HRC fuse/MCB for short circuit protection, Microprocessar based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/genrator voltage, ...capacity bypass switch and frequency sensing, PCC 1301 controller wisth water temprature.Lube oil pressure/eingine speed, Voltage. amphere/Frequency/KVA, Running-hour counte, No of start, Fault indication, over/Under speed, Fails to starts, low oil preasure, High engine temprature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMF module by pass Mode, Battary charger unit with inbuilt Auto.Mannual and Flot/Boost facility. Upto 62.5KVA

1

77768

77768



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.