Karnataka Housing Board Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Karnataka Housing Board - KHB Tender

Works
Building Construction
Opening Date22 Feb 2024
Closing Date22 Mar 2024
Tender Amount₹ 24,28,80,680 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - ANTI TERMITE Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating a continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, the top surface of the plinth filling, junction of wall and floor, along the external perimeter of the building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 Vm2 including the cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications, SI.No 4.1/ Page No. 5-VOL-2 (Plinth area ( Grid 0-18 - A-S )

1589.35

104

166087.075

... More
code05 - Soling, Providing and Filling in foundation with granite/trap broken [metal100mm and down size with approved M-Sand including hand packing, ramming, watering including the cost of all materials and labour with all lead and lift complete as per specifications. sl.no-7, ITEM CODE-6.4, volume-2. (1st Addenda for vol. 1,2 & 3 schedule of rates w.e.f 21-04-2022)

51.15

2817

144094.665

... More
code06 - PCC Bed , Providing and laying in position plain cement concrete for leveling course for all works in the foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of [steel reinforcement & formwork shall be paid separately)-Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates. sl.no-2.1.2, pg.no-15. volume-1

73.2

5726

419187.12

... More
code07 - Footing Concreting , Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork is to be paid separately)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates si.no-2.2.2.1, pg.no-15. Volume-l.

216.75

7103

1539586.0875

... More
code08 - RCC Pedestal or sub str column Concreting , Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork is to be paid separately)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates si.no-2.2.2.1, pg.no-15. Volume-l.

96.26

11180

1076257.0698

... More
code09 - Plinth Beam Conerting , Providing and laying in position Reinforced cement concrete for all Superstructure of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, the cost of all materials, conforming to the requirements of relevant IS codes quality labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork is to be paid [separately) M25 Design Mix Using 20 mm nominal size graded Crushed coarse aggregates si.no-2.5.2, page no-17, volume-I

70.41

10206

718667.829

... More
code10 - Earth Filling , Filling available excavated earth (excluding rock) in trenches plinths, sides of foundations, and other similar works, etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.SL.No 1.9, Page No.7, volume-1

451.64

224

101348.016

... More
code11 - Providing Size Stone masonry with a hard stone in foundation & plinth with Cement mortar 1:6 (1 cement: 6 coarse sand) SI.no-15.4, page no-9, volume-2.

78.24

5887

460614.528

... More
code12 - PCC M15 for DPC , Providing and laying in position plain cement concrete for leveling course for all works in the foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. SL.NO-2.1.4, PAGE NO-15, Volume-I. ,(For wall of ground floor )

7.82

6300

49272.256

... More
code13 - RCC for Column , Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork is to be paid separately)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. sl.no-2.5.2, pg.no-17, volume-l. , ( UP TO PLINTH BEAM (SUB STR )

18.3

11567

211691.106

... More
code14 - RCC for Column , Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork is to be paid separately)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. sl.no-2.5.2, pg.no-17, volume-l. , ( GROUND FLOOR )

82.3

11567

952031.586

... More
code15 - RCC for Column , Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork is to be paid separately)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. sl.no-2.5.2, pg.no-17, volume-l. , ( FIRST FLOOR )

82.4

11683

962720.4

... More
code16 - RCC for Column , Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork is to be paid separately)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. sl.no-2.5.2, pg.no-17, volume-l. , ( SECOND FLOOR )

77.24

11800

911457.4892

... More
code17 - RCC for Column , Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork is to be paid separately)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. sl.no-2.5.2, pg.no-17, volume-l. , ( THIRD FLOOR )

53.96

11918

643113.6264

... More
code18 - RCC for Column , Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork is to be paid separately)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. sl.no-2.5.2, pg.no-17, volume-l. , ( TERRACE FLOOR )

43.36

12037

521946.8672

... More
code19 - RCC Beam , Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation [works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork is to be paid separately)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates sl.no-2.5.2, pg.no-17, volume-l. ( FIRST FLOOR )

271.35

10887

2954285.136

... More
code20 - RCC Beam , Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation [works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork is to be paid separately)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates sl.no-2.5.2, pg.no-17, volume-l. ( SECOND FLOOR )

241.52

10996

2655809.4696

... More
code21 - RCC Beam , Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation [works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork is to be paid separately)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates sl.no-2.5.2, pg.no-17, volume-l. ( THIRD FLOOR )

271.9324

11106

3020135.62088

... More
code22 - RCC Beam , Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation [works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork is to be paid separately)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates sl.no-2.5.2, pg.no-17, volume-l. ( TERRACE FLOOR )

143.3

11217

1607433.358

... More
code23 - RCC Lintel , Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, [Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork is to be paid separately)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. sl.no-2.5.2, pg.no-17, volume-I. ( GROUND FLOOR )

5.92

10887

64453.1712

... More
code24 - RCC Lintel , Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, [Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork is to be paid separately)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. sl.no-2.5.2, pg.no-17, volume-I. ( FIRST FLOOR )

4.61

10996

50692.6203

... More
code25 - RCC Lintel , Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, [Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork is to be paid separately)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. sl.no-2.5.2, pg.no-17, volume-I. ( SECOND FLOOR )

3.12

11106

34651.344

... More
code26 - RCC Lintel , Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, [Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork is to be paid separately)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. sl.no-2.5.2, pg.no-17, volume-I. ( THIRD FLOOR )

2.84

11217

31857.0184

... More
code27 - RCC Lintel , Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, [Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork is to be paid separately)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. sl.no-2.5.2, pg.no-17, volume-I. ( TERRACE FLOOR )

0.74

11329

8383.7782

... More
code28 - Cill Concrete , Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork is to be paid [separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate sl.no-2.5.2, pg.no-17, volume-l. ( GROUND FLOOR )

2.43

9866

23976.0081

... More
code29 - Cill Concrete , Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork is to be paid [separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate sl.no-2.5.2, pg.no-17, volume-l. ( FIRST FLOOR )

2.39

9965

23817.1626

... More
code30 - Cill Concrete , Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork is to be paid [separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate sl.no-2.5.2, pg.no-17, volume-l. ( SECOND FLOOR )

2.28

10064

22948.1772

... More
code31 - Cill Concrete , Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork is to be paid [separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate sl.no-2.5.2, pg.no-17, volume-l. ( THIRD FLOOR )

1.52

10165

15451.7728

... More
code32 - Cill Concrete , Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork is to be paid [separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate sl.no-2.5.2, pg.no-17, volume-l. ( TERRACE FLOOR )

0.69

10267

7084.437

... More
code33 - RCC Staircase , Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators The cost includes all lead & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork is to be paid separately)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate sl.no-2.5.2, pg.no-17, volume-l. ( GROUND FLOOR TO FIRST FLOOR ) 2 No. of stair

14

10206

142896.6

... More
code34 - RCC Staircase , Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators The cost includes all lead & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork is to be paid separately)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate sl.no-2.5.2, pg.no-17, volume-l. ( FIRST FLOOR TO SECOND FLOOR ) 2 No. of stair

14.91

10308

153706.7427

... More
code35 - RCC Staircase , Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators The cost includes all lead & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork is to be paid separately)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate sl.no-2.5.2, pg.no-17, volume-l. ( SECOND FLOOR TO THIRD FLOOR ) 2 No. of stair

12.03

10412

125257.0818

... More
code36 - RCC Staircase , Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators The cost includes all lead & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork is to be paid separately)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate sl.no-2.5.2, pg.no-17, volume-l. ( THIRD FLOOR TO TERRACE FLOOR ) 2 No. of stair

12.03

10516

126509.6454

... More
code37 - Solid Block Masonry Providing and constructing load bearing wall with Solid Concrete blocks of size 400X200X200mm having block density of more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part 1) 2005 and constructed with CM 1:4 as per IS 2572:2005 including the cost of all materials, labor, scaffolding, and curing, usage charges of machinery, etc complete as per specifications. S. No. 6.32, Page No.17, Volume-2 (GROUND FLOOR)

1081.47

1315

1422781.932

... More
code38 - Solid Block Masonry , Providing and constructing load bearing wall with Solid Concrete blocks of size 400X200X200mm having block density of more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - 1) 2005 and constructed with CM 1:4 as per IS 2572:2005 including the cost of all materials, labor, scaffolding, and curing, usage charges of machinery, etc complete as per specifications. S. No. 6.32, Page No.17, Volume-2 (FIRST FLOOR)

923.1

1328

1226578.356

... More
code39 - Solid Block Masonry , Providing and constructing load bearing wall with Solid Concrete blocks of size 400X200X200mm having block density of more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - 1) 2005 and constructed with CM 1:4 as per IS 2572:2005 including the cost of all materials, labor, scaffolding, and curing, usage charges of machinery, etc complete as per specifications. S. No. 6.32, Page No.17, Volume-2 (SECOND FLOOR)

480.3

1342

644581.812

... More
code40 - Solid Block Masonry , Providing and constructing load bearing wall with Solid Concrete blocks of size 400X200X200mm having block density of more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - 1) 2005 and constructed with CM 1:4 as per IS 2572:2005 including the cost of all materials, labor, scaffolding, and curing, usage charges of machinery, etc complete as per specifications. S. No. 6.32, Page No.17, Volume-2 (THIRD FLOOR)

943.24

1355

1278524.0904

... More
code41 - Solid Block Masonry , Providing and constructing load bearing wall with Solid Concrete blocks of size 400X200X200mm having block density of more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - 1) 2005 and constructed with CM 1:4 as per IS 2572:2005 including the cost of all materials, labor, scaffolding, and curing, usage charges of machinery, etc complete as per specifications. S. No. 6.32, Page No.17, Volume-2 (TERRACE FLOOR)

349.85

1369

478951.647

... More
code42 - RCC Slab , Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork is to be paid separately)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. sl.no-2.5.2, pg.no-17, volume-l. ( GROUND FLOOR )

19.96

10206

203729.724

... More
code43 - RCC Slab , Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork is to be paid separately)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. sl.no-2.5.2, pg.no-17, volume-l. ( FIRST FLOOR )

239.51

10308

2469101.4047

... More
code44 - RCC Slab , Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork is to be paid separately)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. sl.no-2.5.2, pg.no-17, volume-l. ( SECOND FLOOR )

185.49

10412

1931333.0094

... More
code45 - RCC Slab , Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork is to be paid separately)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. sl.no-2.5.2, pg.no-17, volume-l. ( THIRD /TERRACE FLOOR )

105.74

10412

1100971.2244

... More
code46 - Steel , Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding, and anchoring to adjacent members wherever necessary complete as per Design including the cost of material, labor, and usage charges complete as per specifications. (The laps and wastages shall not be measured separately) SI. No. 11.32, Page No.84, Volume-2 (SUB STR - Footing )

159934

105

16889030.4

... More
code47 - Steel , Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding, and anchoring to adjacent members wherever necessary complete as per Design including the cost of material, labor, and usage charges complete as per specifications. (The laps and wastages shall not be measured separately) SI. No. 11.32, Page No.84, Volume-2 (FIRST FLOOR )

72923.67

105

7700739.552

... More
code48 - Steel , Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding, and anchoring to adjacent members wherever necessary complete as per Design including the cost of material, labor, and usage charges complete as per specifications. (The laps and wastages shall not be measured separately) SI. No. 11.32, Page No.84, Volume-2 (SECOND FLOOR )

72562.98

106

7739567.4468

... More
code49 - Steel , Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding, and anchoring to adjacent members wherever necessary complete as per Design including the cost of material, labor, and usage charges complete as per specifications. (The laps and wastages shall not be measured separately) SI. No. 11.32, Page No.84, Volume-2 (THIRD FLOOR )

73643.24

107

7932849.8128

... More
code50 - Steel , Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding, and anchoring to adjacent members wherever necessary complete as per Design including the cost of material, labor, and usage charges complete as per specifications. (The laps and wastages shall not be measured separately) SI. No. 11.32, Page No.84, Volume-2 (TERRACE FLOOR )

10869

108

1182547.2

... More
code51 - Steel , Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding, and anchoring to adjacent members wherever necessary complete as per Design including the cost of material, labor, and usage charges complete as per specifications. (The laps and wastages shall not be measured separately) SI. No. 11.32, Page No.84, Volume-2 (SUPER TERRACE )

10323

108

1123142.4

... More
code52 - Door Frame , Providing Red Sandalwood frames of doors, windows, clerestory windows, ventilators, and other frames, wrought, framed, or assembled including making plaster groves (excluding the cost of cement concrete and side clamps), but including the cost of materials, labour, usage charges complete as per specifications. SI.No 12.13.2, Page No. 100, Volume- 2.( GROUND FLOOR )

10869

109

1194503.1

... More
code53 - Door Frame , Providing Red Sandalwood frames of doors, windows, clerestory windows, ventilators, and other frames, wrought, framed, or assembled including making plaster groves (excluding the cost of cement concrete and side clamps), but including the cost of materials, labour, usage charges complete as per specifications. SI.No 12.13.2, Page No. 100, Volume- 2.( FIRST FLOOR )

10323

109

1134497.7

... More
code54 - Door Frame , Providing Red Sandalwood frames of doors, windows, clerestory windows, ventilators, and other frames, wrought, framed, or assembled including making plaster groves (excluding the cost of cement concrete and side clamps), but including the cost of materials, labour, usage charges complete as per specifications. SI.No 12.13.2, Page No. 100, Volume- 2.( GROUND FLOOR )

113.84

67763

7714174.072

... More
code55 - Door Frame , Providing Red Sandalwood frames of doors, windows, clerestory windows, ventilators, and other frames, wrought, framed, or assembled including making plaster groves (excluding the cost of cement concrete and side clamps), but including the cost of materials, labour, usage charges complete as per specifications. SI.No 12.13.2, Page No. 100, Volume- 2.( FIRST FLOOR )

61.37

68440

4200162.8

... More
code56 - Door Frame , Providing Red Sandalwood frames of doors, windows, clerestory windows, ventilators, and other frames, wrought, framed, or assembled including making plaster groves (excluding the cost of cement concrete and side clamps), but including the cost of materials, labour, usage charges complete as per specifications. SI.No 12.13.2, Page No. 100, Volume- 2.( SECOND FLOOR )

31.37

69125

2168461.9158

... More
code57 - Door Frame , Providing Red Sandalwood frames of doors, windows, clerestory windows, ventilators, and other frames, wrought, framed, or assembled including making plaster groves (excluding the cost of cement concrete and side clamps), but including the cost of materials, labour, usage charges complete as per specifications. SI.No 12.13.2, Page No. 100, Volume- 2.( THIRD FLOOR )

61

69816

4258812.6

... More
code58 - Door Frame , Providing Red Sandalwood frames of doors, windows, clerestory windows, ventilators, and other frames, wrought, framed, or assembled including making plaster groves (excluding the cost of cement concrete and side clamps), but including the cost of materials, labour, usage charges complete as per specifications. SI.No 12.13.2, Page No. 100, Volume- 2.( TERRACE FLOOR )

6.3

70514

444242.988

... More
code59 - Window , Providing & fixing of 3-track X 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TO2(Titanium Dioxide) at 6PHR with TE(Thermo Plastic Elastomer) and lead free, gaskets - grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width X 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 75mm with GI reinforcement of 2mm and mesh sash of size 37mm X 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm X 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm X 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) SI. No. 12.90, Page No. 112, Volume-2. ( GROUND FLOOR )

132.45

7964

1054831.8

... More
code60 - Window , Providing & fixing of 3-track 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TO2(Titanium Dioxide) at 6PHR with TE(Thermo Plastic Elastomer) and lead free, gaskets - grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width X 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 75mm with GI reinforcement of 2mm and mesh sash of size 37mm X 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm X 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) SI. No. 12.90, Page No. 112, Volume-2. ( FIRST FLOOR )

131.84

8043

1060473.4976

... More
code61 - Window , Providing & fixing of 3-track 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TO2(Titanium Dioxide) at 6PHR with TE(Thermo Plastic Elastomer) and lead free, gaskets - grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width X 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 75mm with GI reinforcement of 2mm and mesh sash of size 37mm X 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) SI. No. 12.90, Page No. 112, Volume-2. ( SECOND FLOOR )

124.96

8124

1015185.0368

... More
code62 - Window , Providing & fixing of 3-track X 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TO2(Titanium Dioxide) at 6PHR with TE(Thermo Plastic Elastomer) and lead free, gaskets - grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width X 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 75mm with GI reinforcement of 2mm and mesh sash of size 37mm X 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) SI. No. 12.90, Page No. 112, Volume-2. ( THIRD FLOOR )

86.8

8205

712221.776

... More
code63 - Window , Providing & fixing of 3-track X 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TO2(Titanium Dioxide) at 6PHR with TE(Thermo Plastic Elastomer) and lead free, gaskets - grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 75mm with GI reinforcement of 2mm and mesh sash of size 37mm X 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) SI. No. 12.90, Page No. 112, Volume-2. ( TERRACE FLOOR )

39.81

8287

329920.1997

... More
code64 - Providing & fixing of louvered Ventilator made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE Thermo Plastic Elastomer and lead free with gaskets grey color having isolated drainage and reinforced with Galvanized Iron profile through out the ventilator frame. The frame has an overall size of 39mm x 39mm with a Gl reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white will be used on the frame along with plastic parts for fixing the 4 mm pinhead glass. The wall thickness of the frame shall be 2mm. Maximum possible size 1000mm X 1000mm. (The cost is inclusive of all fixtures and separate charges for [minor T&Ps shall not be made) SI. No.12.85 Page No.1110, Volume 2. ( GROUND FLOOR )

25.89

5357

138692.73

... More
code65 - Providing & fixing of louvered Ventilator made out of multi-chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead-free with gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame has an overall size of 39mm x 39mm with a Gl reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pinhead glass. The wall thickness of the frame shall be 2mm. Maximum possible size - 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for [minor T&Ps shall not be made) SI. No.12.85 Page No.1110, Volume-2. ( FIRST FLOOR )

18.96

5357

101568.72

... More
code66 - Providing & fixing of louvered Ventilator made out of multi-chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead-free with gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame has an overall size of 39mm x 39mm with a Gl reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pinhead glass. The wall thickness of the frame shall be 2mm. Maximum possible size - 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for [minor T&Ps shall not be made) SI. No.12.85 Page No.1110, Volume-2. ( SECOND FLOOR )

5.1

5357

27320.7

... More
code67 - Providing & fixing of louvered Ventilator made out of multi-chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead-free with gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame has an overall size of 39mm x 39mm with a Gl reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pinhead glass. The wall thickness of the frame shall be 2mm. Maximum possible size - 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for [minor T&Ps shall not be made) SI. No.12.85 Page No.1110, Volume-2. ( THIRD FLOOR )

7.47

5357

40016.79

... More
code68 - Providing and fixing flush Door Shutters made out of solid core block board type, well seasoned, chemically treated hardwood battens and internal frame with minimum 45 mm wide wooden frame around door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-35 mm thick on both sides commercial, Sl. No. 12.57.6, Page No.106, Volume-2. ( GROUND FLOOR )

95.54

3238

309396.736

... More
code69 - Providing and fixing flush Door Shutters made out of solid core block board type, well seasoned, chemically treated hardwood battens and internal frame with minimum 45 mm wide wooden frame around door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I)1991. from manufacturer complete as per spcification.-35 mm thick on both sides commercial, Sl. No. 12.57.6, Page No.106, Volume-2. ( FIRST FLOOR )

43.61

3270

142638.7158

... More
code70 - Providing and fixing flush Door Shutters made out of solid core block board type, well seasoned, chemically treated hardwood battens and internal frame with minimum 45 mm wide wooden frame around door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I)1991. from manufacturer complete as per spcification.-35 mm thick on both sides commercial, Sl. No. 12.57.6, Page No.106, Volume-2. ( SECOND FLOOR )

17.69

3303

58438.7381

... More
code71 - Providing and fixing flush Door Shutters made out of solid core block board type, well seasoned, chemically treated hardwood battens and internal frame with minimum 45 mm wide wooden frame around door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I)1991. from manufacturer complete as per spcification.-35 mm thick on both sides commercial, Sl. No. 12.57.6, Page No.106, Volume-2. ( THIRD FLOOR )

54.24

3336

180973.3872

... More
code72 - Providing and fixing flush Door Shutters made out of solid core block board type, well seasoned, chemically treated hardwood battens and internal frame with minimum 45 mm wide wooden frame around door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-35 mm thick on both sides commercial, Sl. No. 12.57.6, Page No.106, Volume-2. ( TERRACE FLOOR )

3.6

30

110.304

... More
code73 - Door Fixing of the door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of the frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including the cost of materials, and labour charges, complete as per specifications. sl.no-12.51, pg.no-105, volume-2.

46

1633

75141

... More
code74 - Door Fixtures , Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. SL.NO-12.60 , PG.NO-107, VOLUME-2.

46

915

42099.2

... More
code75 - Providing and fixing chromium-plated brass handles of 100/125 mm with necessary screws etc. complete. SL.NO-12.62, PG.NO 107, VOLUME-2. ( Double+ Single Shtters )

148

192

28490

... More
code76 - Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : (100x85x5.5mm. (heavy type)SI.no-12.75.3, pg.no-109,volume-2.) ( Double+ Single Shtters )

270

168

45441

... More
code77 - Providing and fixing MS Hold fasts (SL. No 285, Page No.A-21, Basic Rate Rs. 32.00), volume-2.

276

35

9715.2

... More
code78 - Providing and fixing Window M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding, SI. No. 11.34A, Page No. 85,Volume-2. ( GROUND FLOOR )

132.45

161

21417.165

... More
code79 - Providing and fixing Window M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding, SI. No. 11.34A, Page No. 85,Volume-2. ( FIRST FLOOR )

123.84

163

20225.5488

... More
code80 - Providing and fixing Window M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding, SI. No. 11.34A, Page No. 85,Volume-2. ( SECOND FLOOR )

124.96

164

20612.152

... More
code81 - Providing and fixing Window M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding, SI. No. 11.34A, Page No. 85,Volume-2. ( THIRD FLOOR )

56.83

166

9467.878

... More
code82 - Providing and fixing Window M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding, SI. No. 11.34A, Page No. 85,Volume-2. ( TERRACE FLOOR )

39.81

168

6698.8287

... More
code83 - Providing 12 mm Cement Plaster with Cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete. SI. No. 8.6.1, Page No. 42, Volume-2. (GROUND FLOOR )

1597.33

301

481435.262

... More
code84 - Providing 12 mm Cement Plaster with Cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete. SI. No. 8.6.1, Page No. 42, Volume-2. (FIRST FLOOR )

1589.35

304

483814.0335

... More
code85 - Providing 12 mm Cement Plaster with Cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete. SI. No. 8.6.1, Page No. 42, Volume-2. (SECOND FLOOR )

1613.01

307

495936.0546

... More
code86 - Providing 12 mm Cement Plaster with Cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete. SI. No. 8.6.1, Page No. 42, Volume-2. ( THIRD FLOOR )

498.65

310

154845.7845

... More
code87 - Providing 12 mm Cement Plaster with Cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete. SI. No. 8.6.1, Page No. 42, Volume-2. TERRACE FLOOR )

498.65

313

156396.586

... More
code88 - Providing 15 mm cement Internal Plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SI.No 8.7, Page No.42, Volume-2. ( GROUND FLOOR )

1772.92

342

606515.932

... More
code89 - Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SI.No 8.7, Page No.42, Volume-2. ( FIRST FLOOR )

1380.54

345

477004.1808

... More
code90 - Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SI.No 8.7, Page No.42, Volume-2. ( SECOND FLOOR )

611.72

348

213478.0456

... More
code91 - Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SI.No 8.7, Page No.42, Volume-2. ( THIRD FLOOR )

1584.26

352

558404.1222

... More
code92 - Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SI.No 8.7, Page No.42, Volume-2. ( TERRACE FLOOR )

461.04

355

164125.6296

... More
code93 - Providing 18 mm cement External plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SI. No. 8.9, Page No.42, Volume-2. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer in-Charge. SI. No. 8.12, Page No.43, Volume-2. (GROUND FLOOR )

498.17

410

204399.151

... More
code94 - Providing 18 mm cement External plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SI. No. 8.9, Page No.42, Volume-2. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer in-Charge. SI. No. 8.12, Page No.43, Volume-2. (FIRST FLOOR )

557.98

414

231226.912

... More
code95 - Providing 18 mm cement External plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SI. No. 8.9, Page No.42, Volume-2. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer in-Charge. SI. No. 8.12, Page No.43, Volume-2. (SECOND FLOOR )

396.91

418

166126.6805

... More
code96 - Providing 18 mm cement External plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SI. No. 8.9, Page No.42, Volume-2. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer in-Charge. SI. No. 8.12, Page No.43, Volume-2. (THIRD FLOOR )

396.54

422

167629.3542

... More
code97 - Providing 18 mm cement External plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SI. No. 8.9, Page No.42, Volume-2. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer in-Charge. SI. No. 8.12, Page No.43, Volume-2. (THIRD FLOOR )

273.63

426

116829.0648

... More
code98 - PCC Bed for Flooring , Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. Page 15, SI. No.2.1.4, Volume-I ( GROUND FLOOR - PLINTH BEAM )

119.2

6300

751055.36

... More
code99 - Providing and laying Cinder Filling Concrete in cement 1:15 (1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. SI. No 7.18, Page No.23, Volume-2. ( GROUND FLOOR )

16.3

2218

36164.81

... More
code100 - Providing and laying Cinder Filling Concrete in cement 1:15 (1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. SI. No 7.18, Page No.23, Volume-2. ( FIRST FLOOR )

26.3

2240

58935.407

... More
code101 - Providing and laying Cinder Filling Concrete in cement 1:15 (1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. SI. No 7.18, Page No.23, Volume-2. ( SECOND FLOOR )

9.1

2263

20596.03

... More
code102 - Providing and laying Cinder Filling Concrete in cement 1:15 (1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. SI. No 7.18, Page No.23, Volume-2. ( THIRD FLOOR )

105.75

2285

241737.0975

... More
code103 - Granite For Staircase , Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications. sl.no-9.30, pg.no-64, volume-2. ( GROUND TO FIRST FLOOR - 2 No.)

148.01

2634

389932.345

... More
code104 - Granite For Staircase , Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications. sl.no-9.30, pg.no-64, volume-2. ( FIRST TO SECOND FLOOR - 2 No.)

116.1

2660

308924.685

... More
code105 - Granite For Staircase , Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications. sl.no-9.30, pg.no-64, volume-2. ( SECOND TO THIRD FLOOR - 2 No.)

105.76

2687

284224.712

... More
code106 - Providing and laying Vitrified Floor Tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm, sl.no-9.12.2, pg.no-60.volume-2. ( GROUND FLOOR )

1738.37

1195

2078569.009

... More
code107 - Providing and laying Vitrified Floor Tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm, sl.no-9.12.2, pg.no-60.volume-2. ( FIRST FLOOR )

1650.08

1207

1992735.6128

... More
code108 - Providing and laying Vitrified Floor Tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm, sl.no-9.12.2, pg.no-60.volume-2. ( SECOND FLOOR )

1665.55

1219

2031521.3015

... More
code109 - Providing and laying Vitrified Floor Tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm, sl.no-9.12.2, pg.no-60.volume-2. ( THIRD FLOOR )

1684.64

1231

2075358.5552

... More
code110 - Providing and laying Vitrified Floor Tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm, sl.no-9.12.2, pg.no-60.volume-2. ( TERRACE FLOOR )

236.8

1244

294638.4

... More
code111 - Providing and laying Vitrified Floor Tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm, sl.no-9.12.2, pg.no-60.volume-2. ( SUPER TERRACE FLOOR )

294.03

1256

369504.5607

... More
code112 - Providing and fixing 1st quality ceramic glazed Wall Tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. SI. No 10.14, Page No.71, Volume-2. ( GROUND FLOOR )

188.23

1060

199599.092

... More
code113 - Providing and fixing 1st quality ceramic glazed Wall Tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. SI. No 10.14, Page No.71, Volume-2. ( FIRST FLOOR )

188.23

1071

201594.33

... More
code114 - Providing and fixing 1st quality ceramic glazed Wall Tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. SI. No 10.14, Page No.71, Volume-2. ( SECOND FLOOR )

115.69

1081

125143.0299

... More
code115 - Providing and fixing 1st quality ceramic glazed Wall Tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. SI. No 10.14, Page No.71, Volume-2. ( THIRD FLOOR )

115.69

1092

126394.7957

... More
code116 - Ceiling Painting , Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 It/10 m2 over and including one coat of Specialprimer applied @ 0.75 Itr /10 m with paint of approved quality to given even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.SI.No 8.33.1, Page No.46, Volume-2. ( GROUND FLOOR )

1597.33

129

207333.434

... More
code117 - Ceiling Painting , Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 It/10 m2 over and including one coat of Specialprimer applied @ 0.75 Itr /10 m with paint of approved quality to given even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.SI.No 8.33.1, Page No.46, Volume-2. ( FIRST FLOOR )

1589.35

131

208363.785

... More
code118 - Ceiling Painting , Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 It/10 m2 over and including one coat of Specialprimer applied @ 0.75 Itr /10 m with paint of approved quality to given even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.SI.No 8.33.1, Page No.46, Volume-2. ( SECOND FLOOR )

1613.01

132

213578.6541

... More
code119 - Ceiling Painting , Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 It/10 m2 over and including one coat of Specialprimer applied @ 0.75 Itr /10 m with paint of approved quality to given even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.SI.No 8.33.1, Page No.46, Volume-2. ( THIRD FLOOR )

1849.54

133

247338.9842

... More
code120 - Ceiling Painting , Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 It/10 m2 over and including one coat of Specialprimer applied @ 0.75 Itr /10 m with paint of approved quality to given even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.SI.No 8.33.1, Page No.46, Volume-2. ( TERRACE FLOOR )

498.65

135

67352.6555

... More
code121 - Internal Plaster , Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications Two coats applied on walls @ 1.25 It/10 m over and including one coat of Specialprimer applied @ 0.75 Itr /10 m with paint of approved quality to given even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.SI.No 8.33.1, Page No.46, Volume-2. ( GROUND FLOOR )

1772.92

129

230125.016

... More
code122 - Internal Plaster , Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications Two coats applied on walls @ 1.25 It/10 m over and including one coat of Specialprimer applied @ 0.75 Itr /10 m with paint of approved quality to given even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.SI.No 8.33.1, Page No.46, Volume-2. (FIRST FLOOR )

1380.54

131

180988.794

... More
code123 - Internal Plaster , Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications Two coats applied on walls @ 1.25 It/10 m over and including one coat of Specialprimer applied @ 0.75 Itr /10 m with paint of approved quality to given even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.SI.No 8.33.1, Page No.46, Volume-2. ( SECOND FLOOR )

611.72

132

80997.8452

... More
code124 - Internal Plaster , Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications Two coats applied on walls @ 1.25 It/10 m over and including one coat of Specialprimer applied @ 0.75 Itr /10 m with paint of approved quality to given even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.SI.No 8.33.1, Page No.46, Volume-2. ( THIRD FLOOR )

1584.26

133

211863.0898

... More
code125 - Internal Plaster , Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications Two coats applied on walls @ 1.25 It/10 m over and including one coat of Specialprimer applied @ 0.75 Itr /10 m with paint of approved quality to given even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.SI.No 8.33.1, Page No.46, Volume-2. ( TERRACE FLOOR )

461.04

135

62272.6728

... More
code126 - External Painting , Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 It/10 m over and including priming coat of exterior primer applied @ 2.20 kg/10 m2) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SI.No 8.30, Page No.46, Volume-2. ( GROUND FLOOR )

498.17

149

74526.232

... More
code127 - External Painting , Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 It/10 m over and including priming coat of exterior primer applied @ 2.20 kg/10 m2) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SI.No 8.30, Page No.46, Volume-2. ( FIRST FLOOR )

557.98

151

84310.778

... More
code128 - External Painting , Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 It/10 m over and including priming coat of exterior primer applied @ 2.20 kg/10 m2) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SI.No 8.30, Page No.46, Volume-2. ( SECOND FLOOR )

396.91

152

60572.4351

... More
code129 - External Painting , Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 It/10 m over and including priming coat of exterior primer applied @ 2.20 kg/10 m2) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SI.No 8.30, Page No.46, Volume-2.( THIRD FLOOR )

396.54

154

61118.7102

... More
code130 - External Painting , Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 It/10 m over and including priming coat of exterior primer applied @ 2.20 kg/10 m2) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SI.No 8.30, Page No.46, Volume-2. ( TERRACE FLOOR )

273.63

155

42595.9821

... More
code131 - Priming Coat - Wood Surface , Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge.SI. No 8.55.1, Page No.51, Volume-2. ( GROUND FLOOR )

121.41

45

5475.591

... More
code132 - Priming Coat - Wood Surface , Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge.SI. No 8.55.1, Page No.51, Volume-2. ( FIRST FLOOR )

54.37

45

2476.5535

... More
code133 - Priming Coat - Wood Surface , Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge.SI. No 8.55.1, Page No.51, Volume-2. ( SECOND FLOOR )

31.37

46

1443.3337

... More
code134 - Priming Coat - Wood Surface , Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge.SI. No 8.55.1, Page No.51, Volume-2. ( THIRD FLOOR )

61

46

2834.67

... More
code135 - Priming Coat - Wood Surface , Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge.SI. No 8.55.1, Page No.51, Volume-2. ( TERRACE FLOOR )

6.3

46

295.659

... More
code136 - Enamel Painting ( wood based) Polishing on wood work with ready mixed wax polish of approved brand and manufacture: New work to give an even surface including preparing the surface after thorougly cleaning oil, grease dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.sl.no-8.47, pg.no-49. ( GROUND FLOOR )

458.61

117

53978.397

... More
code137 - Enamel Painting ( wood based) Polishing on wood work with ready mixed wax polish of approved brand and manufacture: New work to give an even surface including preparing the surface after thorougly cleaning oil, grease dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.sl.no-8.47, pg.no-49. ( FIRST FLOOR )

209.32

118

24883.9616

... More
code138 - Enamel Painting ( wood based) Polishing on wood work with ready mixed wax polish of approved brand and manufacture: New work to give an even surface including preparing the surface after thorougly cleaning oil, grease dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.sl.no-8.47, pg.no-49. ( SECOND FLOOR )

84.9

120

10193.943

... More
code139 - Enamel Painting ( wood based) Polishing on wood work with ready mixed wax polish of approved brand and manufacture: New work to give an even surface including preparing the surface after thorougly cleaning oil, grease dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.sl.no-8.47, pg.no-49. ( THIRD FLOOR )

260.35

121

31572.6445

... More
code140 - Enamel Painting ( wood based) Polishing on wood work with ready mixed wax polish of approved brand and manufacture: New work to give an even surface including preparing the surface after thorougly cleaning oil, grease dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.sl.no-8.47, pg.no-49. ( TERRACE FLOOR )

17.28

121

2095.5456

... More
code141 - Providing and fixing Stainless Steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.SI.No 11.28, Page No.83, Volume-2.(GROUND FLOOR )

17.3

1375

23787.5

... More
code142 - Providing and fixing Stainless Steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.SI.No 11.28, Page No.83, Volume-2. ( FIRST FLOOR )

18.64

1388

25886.3

... More
code143 - Providing and fixing Stainless Steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.SI.No 11.28, Page No.83, Volume-2. ( SECOND FLOOR )

14.63

1402

20520.6232

... More
code144 - Providing and fixing Stainless Steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.SI.No 11.28, Page No.83, Volume-2. ( THIRD FLOOR )

14.63

1416

20725.7358

... More
code145 - Providing and laying in position Plain Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. Page 15, SI. No.2.1.4, Volume-I ( TERRACE FLOOR )

47.48

6489

308136.6536

... More
code146 - Providing 15 mm cement Plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials labour, curing complete as per specifications and as per directions of Engineer-in-charge. SI.No 8.7, Page No.42, Volume-2. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin-Charge. SI. No. 8.12, Page No.43, Volume-2. ( TERRACE PLASTER )

26.6

406

10803.856

... More
code147 - Providing and laying Water Proofing Treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. sl.no-15.1, pg.no-133. volume-2. ( GROUND FLOOR )

102.66

819

84129.87

... More
code148 - Providing and laying Water Proofing Treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. sl.no-15.1, pg.no-133. volume-2. ( FIRST FLOOR )

102.66

827

84971.682

... More
code149 - Providing and laying Water Proofing Treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. sl.no-15.1, pg.no-133. volume-2. (SECOND FLOOR )

57.82

835

48335.7854

... More
code150 - Providing and laying Water Proofing Treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. sl.no-15.1, pg.no-133. volume-2. (THIRD FLOOR )

57.82

844

48819.1606

... More
code151 - Providing and laying Water Proofing Treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. sl.no-15.1, pg.no-133. volume-2. (TERRACE FLOOR )

474.81

852

404908.4718

... More
code152 - Truss Work , Providing and fixing Steel work in built up tubular (round, square or kg rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.

94567.75

149

14147335.4

... More
code153 - Auditoriam Roofing , Providing & fixing corrugated G.S. sheet roofing including vertical I curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge. 0.63 mm thick with zinc coating not less than 275 g/m. Providing & fixing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete as per design drawings.

1350.97

874

1181423.265

... More
code154 - Elevation treatment in GRC with finish as per the satisfaction of architect and Engineer in charge

3280.87

5918

19416188.66

... More
code155 - Providing, supplying and installing the toilet partition of required size with 2000mm height , door size 600mmX1785 mm, with compact laminate of 12mm thickness , using Nylon adjustable foot, gravity hinges, coat hook and door knob, nylon tumb turm indicator, Aluminium powder coated black U channel, Aluminium powder coated door stopper with screws and rubber. As per the satisfaction fo Engineer In charge

60

35000

2100000

... More
code156 - Urinal Partition Providing, supplying and installing the urinal partition of required size of 900mmX450 mm , with compact laminate of 12mm thickness , As per the satisfaction fo Engineer In charge

32

7000

224000

... More
code157 - Urinal Partition Providing, supplying and installing the urinal partition of required size of 900mmX450 mm , with compact laminate of 12mm thickness , As per the satisfaction fo Engineer In charge

32

6489

207674.24

... More
code158 - Earth work excavation for foundation of structures by mechanical means as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising / transporting the remaining earth locally upto 1.00km lead. (Depth upto 3.00 Mts) -In all types of soil (drainage pipeline + water supply lines - oht)(Item Code - 2.23.1)

69.19

57

3957.668

... More
code159 - KSRB 2-4 : Refilling available earth around pipe lines, cables in layers not exceeding 20cms in depth, compacting each deposited layer by ramming after watering with lead upto 50m. and lift upto 1.5 m. including cost of all labour complete as per specifications.(Item Code - 2.11)(As per Item No.2.4)

69.19

133

9209.189

... More
code160 - KSRB 4-1.7 : Providing and laying in position plain cement concrete of mix 1:3:6 with OPC cement @ 220kgs, with 20mm and down size graded granite metal coarse aggregates @0.84cum and fine aggregtes @ 0.56cum, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, plinth and cills, ncluding cost of all materials, labour, HOM of machinery, curing complete as per specifications.INSPECTION CHAMBERS & MAN HOLES Specification No. KBS 4.1, 4.2 (Item Code - 4.7)

1.23

5957

7327.725

... More
code161 - Providing and fixing to wall, ceiling and floor unplasticised PVC pipes 10.00 kgf/sq.cm working pressure chemp plast / Wavin or equivalent make with pipe fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials,with 90mm outer dia.Toilet & Vertical ITEM NO: 11.56.2 (Item Code - 13.70.3)

380

418

158840

... More
code162 - Providing and fixing to wall, ceiling and floor unplasticised PVC pipes 10.00 kgf/sq.cm working pressure chemp plast / Wavin or equivalent make with pipe fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials,with 110mm outer dia.Toilet & Vertical ITEM NO: 11.56.2 (Item Code - 13.70.5)

387

495

191565

... More
code163 - Providing and fixing to wall, ceiling and floor unplasticised PVC pipes 10.00 kgf/sq.cm working pressure chemp plast / Wavin or equivalent make with pipe fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials,with 160mm outer dia.CHAMBER CONNECTIONS ITEM NO:11.56.4 (Item Code - 13.70.7)

111

689

76556.7

... More
code164 - KSRB 11-5 : Providing and fixing white vitreous china clay, water closet European type ( Pedestal type, P-trap ) with black solid plastic seat and lid, C.P brass hinges, rubber buffers. 10 litre low level, P.V.C flushing cistern ( all are approved make ) with fittings, C.I / M.S brackets, 40mm diameter flush bend with fittings and clamps, overflow arrangements with special and 25mm mosquito proof coupling of approved design, painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specifications. Specification No. KBS 11 Water closet European type (Item Code - 12.5)

70

5451

381612

... More
code165 - KSRB 11-9.1 : Providing and fixing white vitreous china clay, flat back or half stall urinal basin of size 580x380x350mm with 5 litres P.V.C automatic flushing cistern, C.I / M.S brackets, standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps C.I dtrap with outlet grating and other couplings in C.P brass, painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specifications.Lipped front urinal basin (Item Code - 12.15)

31

5472

169647.5

... More
code166 - KSRB 11-11.2: Providing and fixing white vitreous china clay, flat back wash basin size 630x450mm with a single 15mm C.P brass pillar tap with C.l I M.S brackets, 32 mm C.P. brass waste of standard pattern, painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specifications.Toilet Specification No. KBS 11 (Item Code - 12.24)

48

3463

166267.2

... More
code167 - Providing and fixing unplasticised PVC Conncetion pipe with brass union 20mm nominal bore 450mm length of PVC Connection including coat of all materials, labour and HOM of equipments with all leads complete as per specification. White, Basin : Hindware - Oval, CP Pillar cock : Jaquar - Pillar cock, PVC pipe : Kohinoor / Noway / Parryware, CP - Stop cock : Jaquar - Continental, CP Waste coupling : Jaquar - Allied, CP Bottle trap : Jaquar - Allied Surgeon type wash basin (Item Code - 13.47)

48

290

13939.2

... More
code168 - Providing and fixing 7.5 cms to 15.00 cms dia NP grating 100 mm dia. NP grating: Chilly SKG5, Sanitroking Gypsy square flat cut.CI Nahani trap (Item Code - 12.111)

140

165

23100

... More
code169 - KSRB13-6.1-1 : Providing and fixing in position brass bib cock of approved quality 15mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. Specification No.KBS 13.2.2 / 13.3 Brass bib cock ( Item Code - 13.23)

60

209

12540

... More
code170 - KSRB13-6.2-1 : Providing and fixing in position brass stop cock of approved quality 15mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. Specification No.KBS 13.2.2 / 13.3 Stop cock ( Item Code - 13.26)

23

155

3567.3

... More
code171 - KSRB13-6.3-3 : Providing and fixing in position brass gate valve with C.I wheel of approved quality ( screwed end ) 25mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. Specification No.KBS 13.2.6 / 13.3 Brass gate valve 25mm ( Item Code - 13.34)

25

493

12347.5

... More
code172 - Providing and fixing in position brass gate valve with C.I wheel of approved quality ( screwed end ) 32mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. Brass gate valve 32mm (Item Code - 13.35)

20

913

18260

... More
code173 - Providing & fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and cost of cutting chases and making good the same including testing of joints complete.(concealed work including cutting chases and good the walls etc.) - 20mm nominal OD pipes. Internal Toilet (Item Code -13.86.2)

365

258

94352.5

... More
code174 - Providing & fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and cost of cutting chases and making good the same including testing of joints complete.(concealed work including cutting chases and good the walls etc.) - 25mm nominal OD pipes. Poly Venyl Chloride (CPVC) pipes and internal toilet (Item Code - 13.86.3)

290

322

93467

... More
code175 - Providing & fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and cost of cutting chases and making good the same including testing of joints complete.(concealed work including cutting chases and good the walls etc.) - 32mm nominal OD pipes. vertical lines distribution, Internal Toilet, Terrace (Item Code - 13.86.4)

275

411

113135

... More
code176 - Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work). - 40mm nominal OD pipes, Poly Venyl Chloride (CPVC) pipes, cws from oht to Duct, on terrace (Item Code - 13.85.5)

207

370

76736.97

... More
code177 - Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work). - 50mm nominal OD pipes, Bore to Sump, Sump to Sintex & CWS from OHT to Duct (Item Code - 13.85.6)

520

501

260832

... More
code178 - KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded non-modular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4 Main UGD (Item Code - 11.37)

2

16233

32467.6

... More
code179 - KSRB 12-5.3 : Constructing brick masonry circular type manhole 1.22 m internal dia at bottom, 1.68 m deep and 0.56m dia at top, with table moulded and non modular bricks of class designation 50 in cement mortar 1:4, inside cement plaster 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and down size granite metal and making necessary channel in cement concrete M 15 with 20mm and down size granite metal, finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diameter confirming to IS :12592, weight length of cover and frame to be not less than 182 kg, fixed in cement concrete M 15 20mm and down size broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. ( Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4 MAIN UGD ( Item Code - 11.39)

2

32329

64658

... More
code180 - KSRB 12-5.6 :Constructing brick masonry circular type manhole 1.52 m internal dia at bottom 4.18m deep and 0.56m dia at top, with table moulded and non-modular bricks of class designation 50 in cement mortar 1:4, inside cement plaster 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 mixed using 40mm and down size granite metal and making necessary channel in cement concrete 1:2:4 mix with 20mm anddown size granite metal, finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diameter confirming to IS :12592, weight length of cover and frame to be not less than 182 kg, fixed in cement concrete M 15 20mm and down size broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. ( Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4 Rain Water Harvesting (Item Code - 11.43)

2

51789

103578.22

... More
code181 - Constructing brick masonry inspection chamber 450x450mm, and 450mm depth, ( clear inside dimension ) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover withframe (light duty) 455x610mm internal dimensions, weight of cover with frame to be not less than 38 kg ( weight of cover 23kg and weight of frame 15 kg) R.C.C. top slab with cement concrete M 15 with 20mm and downsize granite metal, foundation concrete M 5 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 450x450mm and 450mm depth ( clear inside dimension ) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover withframe (light duty) 450x450mm BUILDING ALROUND (Item Code - 11.50.3)

24

5830

139920

... More
code182 - KSRB 12-8.1 : Constructing brick masonry Inspection Chamber 600x600mm, and 450mm depth, (clear inside dimension) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, CI cover with frame (light duty) 455 x 610 mm internal dimenstions, weight of cover with frame to be not less than 38kg (weight of cover 23kg and weight of frame 15kg) RCC top slab with cement concrete 1:2:4 mix 20mm and downsize granite metal, foundation concrete 1:5:10 with 40mm and down size granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bend concree complete as per standard design including cost of materials, labour charges, curing complee as per specifications. (Item Code - 11.50.2)

8

9359

74879.2

... More
code183 - Extra for Item item no. KSRB 12-.8.1 depth beyound 450mm and brick masonry chamber with table moulded non modular bricks of class designation 50 in cement mortar 1:5 for every 150mm depth or part thereof including coat of materials, labour charges, curing complete as per specifications.(Specification No. KBS) 0.45 to 0.6 & 0.6 to 0.75 the nos are 60 & 40 ( Item Code - 11.51)

12

795

9543.72

... More
code184 - KSRB 13-7.1.2 : Providing and fixing in position 32mm nominal bore gun metal non-return valve horizontal type of approved make including cost of all materials, laboru and HOM of equipments with all leads complete as per specifications. Specification No.13.2.10 / 13.13. FIRST FLOOR (Item Code - 13.53)

1

814

814

... More
code185 - Providing stoneware gully trap of approved quality and make fixing in M15 and plastering with CM 1:3 wherever necessary.( Rate includes cost of all materials, fixtures and lead). 15cms x 10cms GROUND FLOOR ( Item Code - 12.112.2)

3

308

924

... More
code186 - Making wall bore in stone masonry walls and Redoing upto 45cms thick (Item Code - 37.36.1)

10

333

3333.1

... More
code187 - Making wall bore in Brick masonry walls and Redoing 45cms thick ( Item Code - 37.35)

10

138

1386.1

... More
code188 - Drilling holes of 2.50 cms dia (roof/chajja/stone). - - in slabs upto 10 cms thick. RCC BORE ( Item Code - 37.28.2)

1

172

172.71

... More
code189 - KSRB 13-11.1 : Providing and placing on terrace, polyethylene water storage tanks with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials, labour, transport charges, HOM of equipments and testing complete as per specifications.(For 5000 litre capacity) Specification No.KBS 13.22 (Item Code - 13.78)

6

41250

247500

... More
code190 - Providing and fixing in position 50mm nominal bore gun metal non-return valve horizontal type of approved make including cost of all materials, Labour and HOM of equipments with all leads complete as per specifications.(Specifications No. KBS 13.2.10/13.13) Non return valves : Cimberio / RB / Itap (Item Code - 13.55)

2

1463

2926

... More
code191 - Earth work excavation for foundation of structures by mechanical means as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising / transporting the remaining earth locally upto 1.00km lead. (Depth upto 3.00 Mts) -In all types of soil. RAIN WATER HARVESTING PIPELINES (Item Code - 2.23.1)

94.5

80

7588.35

... More
code192 - KSRB 2.2.6 : Excavation 1.5m and above in width in hard rock by chiselling and / or wedging, where blasting is prohibited for foundation of buildings, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5 m. in depth stacking the excavated stuff clear from the edge of excavation with lead upto 50m including cost of labour complete as per specifications. specification. No. KBS. (Item Code - 2.8)

158.4

299

47393.28

... More
code193 - KSRB 2.14-1: Extra for additional lift of 1.5m. or part thereof for excavation In loose/ soft or hard soil including cost of materials, labour complete as per specifications. specification. No. KBS (Item Code - 2.21)

316.8

383

121619.52

... More
code194 - SANITARY &DRAINAGE WORKS, Constructing brick masonry inspection chamber 600x600mm, and 450mm depth, ( clear inside dimension ) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover withframe (light duty) 455x610mm internal dimensions, total weight of cover with frame to be not less than 38 kg ( weight of cover 23kg and weight of frame 15 kg) R.C.C. top slab with cement concrete M 15 with 20mm and downsize granite metal, foundation concrete M 5 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 600x600mm and 450mm depth ( clear inside dimension ) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover withframe (light duty) 600x600mm. ITEM NO: 11.50.1

20

9359

187198

... More
code195 - Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work). - 25mm nominal OD pipes (Item Code - 13.87.3)

40

196

7876

... More
code196 - Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work). - 40mm nominal OD pipes (Item Code - 13.87.5)

40

321

12848

... More
code197 - Providing and fixing to wall, ceiling and floor unplasticised PVC pipes 10.00 kgf/sq.cm working pressure chemp plast / Wavin or equivalent make with pipe fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials,with 110mm outer dia. ITEM NO: 11.56.2 BUILDING ALROUND (Item Code - 13.70.5)

55

495

27225

... More
code198 - Providing and fixing to wall, ceiling and floor unplasticized PVC pipes 10.00 kgf/sq.cm working pressure chemp plast / Wavin or equivalent make with pipe fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials,with 160mm outer dia. ITEM NO:11.56.4 ROADS & DRAINS OUTLET

390

689

268983

... More
code199 - R.O System - Providing RO Drinking water Unit (500LPH Capacity), Water purification plants: Supplying, Installation and Commissioning of automatic Water purification plant (RO+UF) with all accessories piping,product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. (Ref- detailed specification enclosed seperatly). Note:- 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BSI /NFS standards,with BSI / NFS mark . 3. Tenders to be invited for procurement. 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note : Refer the ANNEXURE : F for Detailed Specification of Each components. For 500 LPH SS : Skid Type CHAPTER-23 Water purification Plant P.No. 227&228 Sl.No.1 SOR CODE Y010 of 2021-22 SR (Common Schedule Rates) P.NO. 227 & 228

1

387083

387083

... More
code200 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.. Item No 2.1 (PWD Part-1 Electrical 2022-23, P.NO. 1 TO 4) 2.1.1)Short point upto 3Mtr from tapping point to out let via switch box

41

295

12095

... More
code201 - 2.1.2)Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box

74

412

30488

... More
code202 - 2.1.3)Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box

781

605

472505

... More
code203 - 2.1.4)Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to out let via switches

166

770

127820

... More
code204 - 2.1.5)Three outlet in a row, above 6Mts upto 10Mtr from tapping point to out let via switches box

1

1125

1125

... More
code205 - METAL BOX Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. Item No 3.4(PWD Part-1 Electrical 2022-23, P.NO. 5) 3.4.1) 1-3Way

162

131

21222

... More
code206 - 3.4.2)4-5Way

31

147

4557

... More
code207 - 3.4.3)6 Way

164

226

37064

... More
code208 - 3.4.4)8Way

2

266

532

... More
code209 - 3.4.5) 10-12Way

1

347

347

... More
code210 - 3.4.6)16-18 Way

67

378

25326

... More
code211 - DEEP JUNCTION BOX Suppling and fixing PVC/metal conduit deep junction boxes. Item No 1.5 (PWD Part-1 Electrical 2022-23, P.NO.1 TO 2)1.5.1)19/20mm deep junction box

21

52

1092

... More
code212 - 1.5.2) 25mm deep junction box

875

55

48125

... More
code213 - 1.5.3) 32mm deep junction box

10

73

730

... More
code214 - 1.12)Supply and fixing Metal Fan Box with Round Hook

341

174

59334

... More
code215 - Supplying and mounting 2 nos of 2 way 6amps flush type switches either surface /flush mounted on existing gang box or in 4mm thick plastic sheet and mounted on a flush mounted wooden box and wiring as required . Item No 3.2 (PWD Part-1 Electrical 2022-23, P.NO. - 5)

3

173

519

... More
code216 - Switch mounting polycarbonate plate Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.. Item No 3.5 (PWD Part-1 Electrical 2022-23, P.NO.- 5) 3.5.1)1 to 3 Module

162

162

26244

... More
code217 - 3.5.2) 4 Module

31

186

5766

... More
code218 - 3.5.3) 6 Module

164

260

42640

... More
code219 - 3.5.4)8 Module

2

322

644

... More
code220 - 3.5.5)10-12 Module

1

387

387

... More
code221 - 3.5.6)16-18 Module

67

430

28810

... More
code222 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.. Item No 3.6 3.6.1) 6 Amps one way PWD Part-1 Electrical 2022-23, P.NO. -6)

1076

94

101144

... More
code223 - 3.6.2) 6 Amps Two way

10

162

1620

... More
code224 - 3.6.3) 6 Amps 3way socket.

485

173

83905

... More
code225 - 3.6.4) Stepped Fan Regulator Two Module

341

334

113894

... More
code226 - 3.6.8) 16A mps one way

144

266

38304

... More
code227 - 3.6.11) 6/16A aps universal socket.

144

266

38304

... More
code228 - 3.6.12) tv/telephone socket

23

157

3611

... More
code229 - 3.6.13) rj45/i.o outlet cat 6

39

225

8775

... More
code230 - 3.13 Supplying and fixing of metal clad industrial plugs and sockets. 2pole+earth 250V PLUG 20A

22

235

5170

... More
code231 - Concealed Conduit System: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be convered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. Item No 1.2 1.2.1) 19/20mm dia 2mm thick (PWD Part-1 Electrical 2022-23, P.NO. - 1)

27888

65

1812720

... More
code232 - 1.2.2) 25mm dia 2mm thick

7380

75

553500

... More
code233 - 1.2.3) 32mm dia 2.5mm thick

85

99

8415

... More
code234 - Groove cutting: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. Item No 1.3 1.3.1) 19/20mm dia 2mm thick ( PWD Part-1 Electrical 2022-23, P.NO. - 1)

12250

80

980000

... More
code235 - 1.3.2) 25mm dia 2mm thick

1500

85

127500

... More
code236 - 1.3.3) 32mm dia 2.5mm thick

15

112

1680

... More
code237 - Wiring for lighting /power circuit using one of PVC insulated 1100v grade,multis and Copper conductor single core cable in open or concealed system of wiring. Item No 2.3 2.3.2) 1.5 sqmm (PWD Part-1 Electrical 2022-23, P.NO.-3)

21500

27

580500

... More
code238 - 2.3.3) 2.5 sqmm

8100

42

340200

... More
code239 - 2.3.4) 4 sqmm

4100

63

258300

... More
code240 - 2.3.3) 6 sqmm

300

93

27900

... More
code241 - Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 V as per IS-694:2010.e. Item No 2.6 2.6.2)3C x 2.5 mm2 (PWD Part-1 Electrical 2022-23, P.NO.-4)

30

121

3630

... More
code242 - Supplying and fixing regular MCB distribution boards on wall/ wood board /flush mounting required clamps,bolts,nuts etc.. with provision for fixing suitable type capacity MCB's single phase /3 phase /single door with powder coated painting etc., complete. Item No 5.18, 12 Way TP & N (PWD Part-1 Electrical 2022-23, P.NO. - 13)

4

6135

24540

... More
code243 - 8 Way TP & N

6

4418

26508

... More
code244 - Supplying and fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up 300mA sensitivity on existing wood/panel board. Item No 5.20, 5.20.2)32-40 Amps 2 Pole (PWD Part-1 Electrical 2022-23, P.NO. - 13)

30

2832

84960

... More
code245 - Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 V 1/3 phase motor upto 5 HP.Item No 5.1

1

1591

1591

... More
code246 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and wiring complete as required. Item No 5.17.1)6-32Amps SP (PWD Part-1 Electrical 2022-23, P.NO. - 13)

288

559

160992

... More
code247 - 5.17.9 ) 40 A TPN

6

2555

15330

... More
code248 - 5.17.9 ) 50-63 A TPN

4

2562

10248

... More
code249 - Earthing - Pipe Grounding: GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg (BESCOM Part-3 2021-22, P.NO. - 17)

2

735

1470

... More
code250 - Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each. ITEM NO.54.02

2

687

1375

... More
code251 - Good Quality Salt for grounding purposes packed in 50 Kg gunny bag ITEM NO.54.03) (BESCOM Part-3 2021-22, P.NO.-17)

3

289

867

... More
code252 - Earthing - Rod Earthing Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified. ITEM NO.54.04 (BESCOM Part-3 2021-22, P.NO.-17)

1

2148

2148

... More
code253 - Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified ITEM NO.54.05 (BESCOM Part-3 2021-22, P.NO.-17)

1

343

343

... More
code254 - Digging of Pit for providing GI Pipe type Earthing. In Ordinary Soil. ITEM NO.-1.6 (BESCOM Part-4 2021-22, P.NO. - 1)

1

617

617

... More
code255 - GI strip - Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.. Guy Wire & GI Wire as per IS-2141. 8 SWG GI Wire (4.064 mm Dia), Std Wt: 125 Kg/KM. ITEM NO. 8.02 (BESCOM Part-3 2021-22, P.NO. -65)

0.07

74233

5196.31

... More
code256 - Part- B:- Light Fixtures and fan . Supply an fixing of …feet pvc batten with integrated led tube quality diffuser with life of 25000 burning hours & 70% lumen maintance with CRI 80. power input :220-240V @ 50 hz & power factor .9 along with CE approved drivers. 2 years warranty. Item No 11.30.1 & ITEM NO. 11.3.2 (PWD Part-1 Electrical 2022-23, P.NO.- 34)

11

267

2937

... More
code257 - 11.3.2)LED light fitting 1x4' -20/22w

681

400

272400

... More
code258 - Supply an fixing of …feet pvc batten with integrated led tube quality diffuser with life of 25000 burning hours & 70% lumen maintance with CRI80. power input :220-240V @ 50 hz & power factor .9 along with CE approved drivers. 2 years warranty. Item No 11.5.1, 11.5.3, 12.53)LED square or round down light 5-6W (PWD Part-1 Electrical 2022-23, P.NO. - 34, 44 )

10

583

5830

... More
code259 - 11.5.3)LED square or round down light 15-18W

194

1334

258796

... More
code260 - Supplying and fixing of round or oblong type bulk head fitting glass cover

5

73

365

... More
code261 - Supplying exhaust fan of 1440 RPM of 300 mm (12'') size with bracket blades complete for light duty suitable for operate of 230V 50Hz, AC Supply. Item No 6.2 1 Sweep (300 mm) (PWD Part-1 Electrical 2022-23, P.NO.- 22)

14

3200

44800

... More
code262 - Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/197.Item No 6.4.1 48" Sweep (1200mm)Regular model (Khaitan, Crompton Greaves, Orient, Polar, Bajaj, Usha, Havells, Almonard) (PWD Part-1 Electrical 2022-23, P.NO. - 23)

341

3150

1074150

... More
code263 - PART -C -1 UG CABLES Supplying of LT UG cable having aluminium conductor PVC insulated, sheathed, galvanised, steel wire/steel tap armoured cable with PVC outer sheathing 1.1 KV class .1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm) ITEM NO . - 32.11 (BESCOM PART-3 2021-22, P.NO.-9)

0.1

25885

2588.5

... More
code264 - Supplying tinnd copper lugs and crimping and wiring to terminal point for wire of the following sizes. Heavy Duty Copper Terminal Long Barrel 50 Sqmm Copper Terminal, Apprx Wt: 26 Gm. ITEM NO. - 63.03 (BESCOM PART-3 2021-22, P.NO.-20)

2

64

128

... More
code265 - Supplying and fixing of heavy duty cable glands suitable or UG cable o 1.1KV class (metal only).32 mm dia. ITEM NO. - 70.02 (BESCOM PART-3 2021-22, P.NO.-25)

2

89

178

... More
code266 - 77.22) Supply & fixing of aution/Danger name board as per drawing( BESCOM SR . CDS-1)ITEM NO.- 67.2 ( PWD Part-1 Electrical 2022-23, P.NO. - 24)

1

140

140

... More
code267 - Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. In ordinary (BESCOM PART-4 2021-22 P No. 8 ) ITEM No. 29.02

112.5

278

31275

... More
code268 - Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 Mtr (BESCOM PART-4 2021-22 , P No. 8 ) ITEM NO. 29.07

112.5

62

6975

... More
code269 - 57.07) PVC pipe-75mm dia (Page No 20of 40 Sl no:450) (BESCOM PART-3 2021-22 , P no. - 15 ) ITEM NO. 48.07

20

152

3040

... More
code270 - Supplying and fixing of Shunt trip suitable for MCCB.CBCT Item No 5.15 (PWD Part-1 Electrical 2022-23 , P no. 12 ) ITEM NO. 5.15

1

1615

1615

... More
code271 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Circuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism - Item No 5.14 ( PWD Part-1 Electrical , 2022-23 , P No. 13 ) ITEM NO - 5.14.14 , 500-630 A 50 kA

1

42147

42147

... More
code272 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Circuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism - Item No 5.14 ( PWD Part-1 Electrical , 2022-23 , P No. 12 ) ITEM NO - 5.14.7 , 100 A 25 KA

4

8827

35308

... More
code273 - Supplying of multi function digital meter with three line back light LCD type display for voltage,Current,frequency,Power,Powerfactor,KVA,KWH,KVARsuitable for 3 Phase,4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy. Item No 5.33 ( PWD Part-1 Electrical , 2022-23 ) PAGE 14

8

8939

71512

... More
code274 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Circuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.y.(PWD Part-1 Electrical 2022-23 , PAGE 12 ) Item No 5.14

6

2562

15372

... More
code275 - Supplying …..amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/ERP/DMC insulator which are mounted on powder coated 40x6 mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts,nuts and washers etc.,complete. ( PWD Part-1 Electrical 2022-23 , PAGE 15 )Item No 5.40 . 4 (600 A 4 x 75 x 10 mm Aluminium Strips)

3

5298

15894

... More
code276 - Supplying …..amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/ERP/DMC insulator which are mounted on powder coated 40x6 mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts,nuts and washers etc.,complete. ( PWD Part-1 Electrical 2022-23 , PAGE 15 )Item No 5.40.1 (100 A 4 x 75 x 10 mm Aluminium Strips)

2

2365

4730

... More
code277 - Fabricating supplying and mounting MS box made out 16 SWG suitable for floor/wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete.(PWD Part-1 Electrical 2022-23 Page no. 15) Item No 5.42 , ( 14SWG )

55000

-

25300

... More
code278 - Fabricating supplying and mounting MS box made out 16 SWG suitable for floor/wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete.(PWD Part-1 Electrical 2022-23 Page no. 15) Item No 5.42 .2, (16SWG )

85000

-

34850

... More
code279 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C.50 Hz 12/24v D.C. Item No 5.38 (PWD Part-1 Electrical 2022-23, P.NO.-14)

6

495

2970

... More
code280 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.. Item No 5.41.1 40 x 40 x 6 mm (PWD Part-1 Electrical 2022-23, P.NO. - 15)

4

294

1176

... More
code281 - NETWORKING & TELECOMUNICATION Item No 8

4838

36

174168

... More
code282 - A ITEM NO . - 8.1 , (PWD Part-1 Electrical 2022-23, P.NO. - 27)

22

68050

1497100

... More
code283 - Providing, supplying and fixing of 12" 2-Way Passive Loudspeaker, 350 W Continuous, Coverage: 90 x 60 Make : EV/JBL Or Equalent approved by Engg incharge ---- ---- etc complete with all lead and lift as per detailed specification and directions of the Engineer incharge.

4

91285

365140

... More
code284 - Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete..10KVA ON LINE UPS Two Hour back up Excluding 10x 60Ah batteries. ITEM NO .- 9.3.5

1

127110

127110

... More
code285 - 12 V 60 / 65 AH capacity CAPACITY ACID BATTERY

10

41290

412900

... More
code286 - Arrange for the 1 energy meter, CESCOM deposit, laisening work and including road cutting permission, etc.etc

1

21350

21350

... More
code287 - Approx lighting fixtures track Light and other focus lights As per require,ents (Non Schedule Rate)

1

4988875

4988875

... More
code288 - Auditorium Flooring Work , Stage - Hardwood Flooring Flooring (including beechwood polish. skirting): Providing and fixing 16/4x100x1200mm planks, 6 layers per PU, tongue and groove and micro bevel all around, finger jointed, laid using full-surface ghing with suitable parquet glue. Cement sub floor should be hard plaster, tight, very smooth on surface, level & completely dry (cured). The risers will be smoothened with a 1 mm Ardex Feather Edge Covering while the step areas will be done with 3 mm Self leveling as per detailed Architectural Drawing including all lead and lifts, at all levels and as per the directions of the Engineer in Charge. (Stage) - Non SR

235

9900

2326500

... More
code289 - Carpet Flooring: (Auditorium Seating Area) 100% solution dyed tufted solid cut pile in wool/Nylon with action Backing, Guage 1/10, 8.00 mm thickness in 36oz per sq yard with of 12 feet, Soil Resistence 8 of 10 Passed. As per the directions of the Engineer in Charge. ( Non SR) (Auditorium Seating)

1053

6050

6370650

... More
code290 - Auditorium Ceiling Work , Providing & Fixing of Anti Microbial Bio-Safe Coated Intergral Densified Tegular/Butt edged Eco Friendly Lightweight Calcium Silicate Suspended Ceiling System without perforation Plain/Designer ceiling Tiles in Module Size of 600x600x15mm with Exposed T24 mm Grid for Hospitals, Institutions, Laboratories, Health Care Units, Offices. The Anti Microbial Bio-Safe lightweight calcium Silicate ceiling tiles shall be made from Non Cementitious Hydrated Calcium Silicate Slurry/Mixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials. Doesn't contain any toxic ingrediants. The Tiles should have Anti Microbial Bio-Safe Coating on front and back sides of tiles confirming to JIS-Z2801 and ASTM G-21 standard by NABL accredited Labs and found to be completely protected from Bacteria, Fungi, Yeast and Mould when exposed to these organisms both room temperature and AC temperature. Tiles should be protected and is free from colony-forming units. The Tiles should have Humidity Resistance (RH) of 100%, Water Resistance, Non Combustible: as per BS:476 Part-4, Fire Performance: as per BS:476 Part-6 for Fire Propagation, as per BS:476 Part-7 for Surface Spread of Flame, As per UK standards Fire Performace A1-S1- d0, Thermal Conductivity K= 0.048 to 0.050 w/m K as per ECBC code 2007, NRC(Noise Reduction Coefficient ) 0.1 to 0.15 (Plain and Designer tiles) as per IS 8225:1987, Sound Attenuation (STA) 30-32dB, Thickness of tile should be 15mm thick with 450 kg/m3 density all around on edge resting portion with Integral Densified edge and 10mm thick with 350 kg/m3 density in the center portion of the body, Light Reflectance 85%, Weight of material is 5-5.5 kg/m2 and Suitable for Green Building application with InOrganic Recycled content of 46- 50% out of which 18-20% should be FLYASH and meets the GRIHA & SVAGRIHA norms under the categories: GRIHA V.2015 criterion:11&12, GRIHA V.3 criterion: 17&29 and SVAGRIHA criterion:12. The tiles Shall be laid on 24mm Wide T-Sections Flanges colour white having rotary stitching on all T sections i.e. the Main runner with a web height of 38mm and 1200mm & 600mm Cross Tees with a web height of 32mm having thickness of 0.33mm and Wall angle of 24*24mm with 0.4 mm thickness , having load carrying capacity of 15 kg/m2. The T sections should have Galvanizing of 120 grams per m2 and need to be installed with Suspension system. Page No. 35, SI. No.7.58 Vol-2

1030

2169

2234276

... More
code291 - Auditorium Wall Panelling Work , Auditorium Seating Area : Providing and supplying 'Acoustical Wall Paneling' with square edges made of fibre glass substrate 25mm thick and wrapped on the front side with an acoustically transparent and classified for Fire reaction Class A, as per ASTM E-84, fabric with option of colors - as per the choice of the Architect/Engineer incharge of the size 600x600mm, 600x1200mm & 600x1800mm providing a minimum sound absorption level of 0.85 NRC to be affixed to wall using Wall panel lmpaler sand construction adhesives as per the instructions laid down by the certified manufacturer. Page No. 32, SI. No.7.51 Vol-2

1070

4766

5099941

... More
code292 - Laminate Panelling: In prefunction Area Providing and fixing Laminate cladding made of 1mm thk laminate, pasted using approved adhesive to 19mm thick MR plywood backing with all exposed edges with 2mm PVC edge banding, screwed to the existing masonry/RCC surface using M8 screws of 30mm length at all corners as per the detailed architectural drawings lead and lifts, at all levels and as directed by the Engineer in Charge. (Non SR)

745

3300

2458500

... More
code293 - Auditorium Chairs , Theatre Chairs: (Auditorium seating)Seating Supplying & installing armest cladding layered fabric, seat sliding feature, steel side panels frames, grouted to floor using anchors with labor charges and complete as per the instructions given by the engineer in-charge. ---- ---- etc complete with all lead and lift as per detailed specification and directions of the Engineer incharge. (Auditorium seating) - Non SR

1400

7637

10691996

... More
code294 - Auditorium Dias , Providing & Fixing of Dias tables with labor charges and where ever necessary complete as per the instructions given by the engineer in-charge. ---- ---- etc complete with all lead and lift as per detailed specification and directions of the Engineer incharge. (Non SR item)

1

9900

9900

... More
code295 - Auditorium Speaker And Display (Non Schedule Items) , Providing, supplying and fixing of 15" 2-Way Passive Loudspeaker, 500 W Continuous, Coverage: 90 x 60Make : EV/JBL Or Equalent approved by Engg incharge. --- ---- etc complete with all lead and lift as per detailed specification and directions of the Engineer incharge.(Non SR item)

8

112860

902880

... More
code296 - Providing, supplying and fixing of 12" 2-Way Passive Loudspeaker, 350 W Continuous, Coverage: 90 x 60 Make : EV/JBL Or Equalent approved by Engg incharge ---- ---- etc complete with all lead and lift as per detailed specification and directions of the Engineer incharge.(Non SR item)

8

70092

560736

... More
code297 - Providing, supplying and fixing of 18" Passive Subwoofer, 400 W Continous, Wood enclosure ---- ---- etc complete with all lead and lift as per detailed specification and directions of the Engineer incharge.(Non SR item)

4

94022

376090

... More
code298 - Live 2x 950W with In built DSP Complete with FIR Filters, Audio Limiters, Output delay per channel, 31 band GEQ per channel, PEQ per channel, Load Impedance and having PC remote control option Make : Dynacord / QSC Or Equ approved by Engg ---- ---- etc complete with all lead and lift as per detailed specification and directions of the Engineer incharge.(Non SR item)

1

112860

112860

... More
code299 - Live 2x 1400W with In built DSP Complete with FIR Filters, Audio Limiters, Output delay per channel, 31 band GEQ per channel, PEQ per channel, Load impedance and having PC remote control option Make : Dynacord / QSC Or Equ approved by Engg ---- ---- etc complete with all lead and lift as per detailed specification and directions of the Engineer incharge.(Non SR item)

1

172260

172260

... More
code300 - Providing, supplying and fixing of 12 Channel Mixer, Max. 6 Mic / 12 Line Inputs (4 mono + 4 stereo) 2 GROUP Buses + 1 Stereo Bus 2 AUX (incl. FX) ---- ---- etc complete with all lead and lift as per detailed specification and directions of the Engineer incharge.(Non SR item)

1

106920

106920

... More
code301 - Powered Stage Monitor Make : EV/JBL Or Equalent approved by Engg incharge ---- ---- etc complete with all lead and lift as per detailed specification and directions of the Engineer incharge. (Non SR item)

4

70202

280808

... More
code302 - High Quality UHF Band Frequency Duet Wireless Microphone System, 80 Selectable UHF Channels, Easy setup of the system with Infra Red Make : AKG/Shure or Equalent Approved make ---- ---- etc complete with all lead and lift as per detailed specification and directions of the Engineer incharge. (Non SR item)

1

77166

77166.1

... More
code303 - High Quality UHF Band Frequency Duet Wireless Microphone System, 80 Selectable UHF Channels, Easy setup of the system with Infra Red Make : AKG/Shure or Equalent Approved make ---- ---- etc complete with all lead and lift as per detailed specification and directions of the Engineer incharge. (Non SR item)

1

77166

77166.1

... More
code304 - Providing, supplying and fixing of Headworn Mic. approved by Engineer in charge ---- ---- etc complete with all lead and lift as per detailed specification and directions of the Engineer incharge. (Non SR item)

1

59400

59400

... More
code305 - Gooseneck Mic. with Base, Electret condenser, 21" mic. length, Anti Mobile & RF Interference Technology Make : AKG/Shure or Equalent Approved make ---- ---- etc complete with all lead and lift as per detailed specification and directions of the Engineer incharge. (Non SR item)

1

77166

77166.1

... More
code306 - Pixeless Smart Podium body made with CRCA steel, duly powder coated, security lock, sliding lock cover for Touch display, space for keyboard & mouse drawer, Connectivity point for Gooseneck & LED Lamp, Built-in Rack on wheels, Rack space to keep the amplifier & mics., space to display the co. logo, Optional choice to integrate a 21.5" Touch Monitor ---- ---- etc complete with all lead and lift as per detailed sp ecification and directions of the Engineer incharge. (Non SR item)

1

112860

112860

... More
code307 - Providing, supplying and fixing of Interactive Tablet, approved by Engineer in charge ---- ---- etc complete with all lead and lift as per detailed specification and directions of the Engineer incharge. (Non SR item)

1

280724

280724.4

... More
code308 - SITC of 3D visualiser for object viewing Make: EPSON / Elmo/Wolfvision/Eqvt approved by Engineer in charge ---- ---- etc complete with all lead and lift as per detailed specification and directions of the Engineer incharge.

1

491059

491059.8

... More
code309 - Providing and fixing of Flush Mounted box 6 slots for vga, hdmi & audio, approved by Engineer in charge ---- ---- etc complete with all lead and lift as per detailed specification and directions of the Engineer incharge. (Non SR item)

3

33264

99792

... More
code310 - Providing and fixing of4 x 4 VGA Matrix Switcher - Milestone, approved by Engineer in charge ---- ---- etc complete with all lead and lift as per detailed specification and directions of the Engineer incharge. (Non SR item)

1

70151

70151.4

... More
code311 - Providing and fixing of4 x 4 HDMI Matrix Switcher - Milestone, approved by Engineer in charge ---- ---- etc complete with all lead and lift as per detailed specification and directions of the Engineer incharge. (Non SR item)

1

140302

140302.8

... More
code312 - Speaker cables Special 16AWG shielded twisted pair copper cable Make: Kramer/Eqvt approved by Engineer in Charge ---- ---- etc complete with all lead and lift as per detailed specification and directions of the Engineer incharge. (Non SR item)

600

2805

1683000

... More
code313 - VGA+Audio cables Make: Extron/Kramer/Eqvt approved by Engineer in charge ---- ---- etc complete with all lead and lift as per detailed specification and directions of the Engineer incharge. (Non SR item)

600

1051

630960

... More
code314 - HDMI cables Make: Extron/Kramer/Eqvt approved by Engineer in charge ---- ---- etc complete with all lead and lift as per detailed specification and directions of the Engineer incharge. (Non SR item)

600

2104

1262580

... More
code315 - Vedio (Demo room) SITC of Projector with Laser Output: 7000 ANSI Lumens or more Native Resolution: WUXGA or better Video Input: HDMI, Composite video input, S-Video Input, VGA Audio Input:Stereo 3.5mm mini jack Control terminals: USB v2.0 or higher, RJ-45, RS 232C Lamp: 400W Lamp life: 6000 hours or more Accessories:Including but not limited to Power cables, Remote control, Dust cover, ceiling mount and other accessories etc ""Warranty: 6000hrs or 3 years on the projector including the lamp/light source. Comprehensive on-site service warranty for all the parts of the projector including lamp/light source. Brightness not less than 75% of the stated value till the end of the warranty period."" Make: Epson/Panasonic/Eqvt approved by Engineer in charge ---- ---- etc complete with all lead and lift as per detailed specification and directions of the Engineer incharge.(Non SR item)

1

950400

950400

... More
code316 - Vedio (Demo room) SITC of Projector with Laser Output: 7000 ANSI Lumens or more Native Resolution: WUXGA or better Video Input: HDMI, Composite video input, S-Video Input, VGA Audio Input:Stereo 3.5mm mini jack Control terminals: USB v2.0 or higher, RJ-45, RS 232C Lamp: 400W Lamp life: 6000 hours or more Accessories:Including but not limited to Power cables, Remote control, Dust cover, ceiling mount and other accessories etc ""Warranty: 6000hrs or 3 years on the projector including the lamp/light source. Comprehensive on-site service warranty for all the parts of the projector including lamp/light source. Brightness not less than 75% of the stated value till the end of the warranty period."" Make: Epson/Panasonic/Eqvt approved by Engineer in charge ---- ---- etc complete with all lead and lift as per detailed specification and directions of the Engineer incharge.(Non SR item)

1

173913

173913.3

... More
code317 - Providing and fixing of 4K TV 65 approved by Engineer in charge ---- ---- etc complete with all lead and lift as per detailed specification and directions of the Engineer incharge. (Non SR item)

4

106920

427680

... More
code318 - Providing and fixing of Ceiling suspended bracket, approved by Engineer in charge ---- ---- etc complete with all lead and lift as per detailed specification and directions of the Engineer incharge. (Non SR item)

2

9801

19602

... More
code319 - Supply & Installtion of 16.5 TR Ductable air conditioner comprising Indoor & out door unit.The out door unit shall comprise hermetic scroll compressor/s in independent refrigerant circuits, HP/LP cutouts, Copper condenser coil and fan.(R410) ( SUPPLY WORK ) (Non SR item)

8

319000

2552000

... More
code320 - Supply & Installtion of 16.5 TR Ductable air conditioner comprising Indoor & out door unit.The out door unit shall comprise hermetic scroll compressor/s in independent refrigerant circuits, HP/LP cutouts, Copper condenser coil and fan.(R410) ( LABOUR WORK )(Non SR item)

8

20000

160000

... More
code321 - Supply and installation of Control Cable 2.5 x 6 Core Indoor to Outdoor unit. ( SUPPLY WORK ) (Non SR item)

250

310

77500

... More
code322 - Supply and installation of Control Cable 2.5 x 6 Core Indoor to Outdoor unit. ( LABOUR WORK )(Non SR item)

250

66

16515

... More
code323 - Supply and installation of Refrigerant copper piping with proper tubular insulation suitable for 16.5 TR condenser unit ( SUPPLY WORK ) (Non SR item)

250

2200

550000

... More
code324 - Supply and installation of Refrigerant copper piping with proper tubular insulation suitable for 16.5 TR condenser unit ( LABOUR WORK ) (Non SR item)

250

155

38750

... More
code325 - Supply, Fabrication, Installation & Balancing of GSS Sheet , Metal Rectangular ducts complete with supports, Gaskets, Nuts & Bolts ( 0.60mm - 24 Gauge ) SUPPLY WORK (Non SR item)

700

1550

1085000

... More
code326 - Supply, Fabrication, Installation & Balancing of GSS Sheet Metal Rectangular ducts complete with supports, Gaskets, Nuts & Bolts ( 0.80mm - 22 Gauge ) SUPPLY WORK (Non SR item)

400

1500

600000

... More
code327 - Supply, Fabrication, Installation & Balancing of GSS Sheet Metal Rectangular ducts complete with supports, Gaskets, Nuts & Bolts ( 0.60mm - 24 Gauge+ 0.80mm -22 Gauge ) LABOUR WORK (Non SR item)

1100

250

275000

... More
code328 - Supply & installation flexible connections constructed of fire resistant flexible double between machine mouth to main duct canvas sleeve with zip provision. ( SUPPLY WORK )

8

3850

30800

... More
code329 - Supply & installation flexible connections constructed of fire resistant flexible double between machine mouth to main duct canvas sleeve with zip provision. ( LABOUR WORK ) (Non SR item)

8

650

5200

... More
code330 - Supply & installation of Aluminium powder quoted supply air diffuser ( SUPPLY WORK )(Non SR item)

128

2450

313600

... More
code331 - Supply & installation of Aluminium powder quoted supply air diffuser ( LABOUR WORK )(Non SR item)

128

675

86400

... More
code332 - Supply & installation of of Aluminum powder quoted Return air diffuser ( SUPPLY WORK ) (Non SR item)

128

2350

300800

... More
code333 - Supply & installation of of Aluminum powder quoted Return air diffuser ( LABOUR WORK ) (Non SR item)

128

155

19840

... More
code334 - Supply, Installation, Testing and Commissioning of Factory Fabricated Insulated Flexible duct made out of aluminium for connecting from main duct to diffuser box. The flexible duct shall be made of double lamination of aluminium foil, polyester and metalised polyester film permanently bonded to a coated spring steel wire helix. The exterior shall be wrapped with 25 mm thick 16 kg/m3 fiberglass insulation. The outer insulation jacket/vapour barrier made of fiberglass reinforced metalised polyester film laminate. Installed flexible duct shall not be more than 1.2 meter and Balance length shall be covered by GI round duct, (which will be paid as per conventional rectangular GI duct cost). The price shall include the cost of grip clamps on both sides.( SUPPLY WORK ) (Non SR item)

210

775

162750

... More
code335 - Supply, Installation, Testing and Commissioning of Factory Fabricated Insulated Flexible duct made out of aluminium for connecting from main duct to diffuser box. The flexible duct shall be made of double lamination of aluminium foil, polyester and metalised polyester film permanently bonded to a coated spring steel wire helix. The exterior shall be wrapped with 25 mm thick 16 kg/m3 fiberglass insulation. The outer insulation jacket/vapour barrier made of fiberglass reinforced metalised polyester film laminate. Installed flexible duct shall not be more than 1.2 meter and Balance length shall be covered by GI round duct, (which will be paid as per conventional rectangular GI duct cost). The price shall include the cost of grip clamps on both sides. ( LABOUR WORK ) (Non SR item)

210

155

32550

... More
code336 - Supply & installation of Butter fly dampers of GI construction made out of 22G sheet with lever, brass bush with spindle and locking arrangement with 300mm dia ( SUPPLY WORK ) (Non SR item)

128

1350

172800

... More
code337 - Supply & installation of Butter fly dampers of GI construction made out of 22G sheet with lever, brass bush with spindle and locking arrangement with 300mm dia ( LABOUR WORK ) (Non SR item)

128

200

25600

... More
code338 - Supply & installation of mixture box / plenum box of GI construction made out of 22G sheet with lever, brass bush with spindle and locking arrangement with 600x600 ( SUPPLY WORK ) (Non SR item)

128

2050

262400

... More
code339 - Supply & installation of mixture box / plenum box of GI construction made out of 22G sheet with lever, brass bush with spindle and locking arrangement with 600x600 ( LABOUR WORK ) (Non SR item)

128

155

19840

... More
code340 - Supply & installation of collar dampers of GI construction made out of 22G sheet with lever, brass bush with spindle and locking arrangement with 600x600 ( SUPPLY WORK ) (Non SR item)

128

1000

128000

... More
code341 - Supply & installation of collar dampers of GI construction made out of 22G sheet with lever, brass bush with spindle and locking arrangement with 600x600 ( LABOUR WORK ) (Non SR item)

128

155

19840

... More
code342 - Supply and fixing of acoustic insulation for internal duct using 10 mm open cell Nitreal Rubber with adhesive. ( SUPPLY WORK ) (Non SR item)

300

1300

390000

... More
code343 - Supply and fixing of acoustic insulation for internal duct using 10 mm open cell Nitreal Rubber with adhesive. ( LABOUR WORK ) (Non SR item)

300

275

82500

... More
code344 - Supply and fixing of thermal insulation for external duct using 9 mm nitreal rubber Class"O" with adhesive. ( SUPPLY WORK) (Non SR item)

600

425

255000

... More
code345 - Supply and fixing of thermal insulation for external duct using 9 mm nitreal rubber Class"O" with adhesive. ( LABOUR WORK )(Non SR item)

600

235

141000

... More
code346 - Supply and charging of R22 /410 refrigerant gas during commissioning of the system ( SUPPLY WORK ) (Non SR item)

120

1350

162000

... More
code347 - PVC Drain pipe with PVC Fittings ( SUPPLY WORK ) (Non SR item)

120

195

23400

... More
code348 - PVC Drain pipe with PVC Fittings ( LABOUR WORK ) (Non SR item)

120

66

7932

... More
code349 - MS Outdoor Stand ( SUPPLY WORK ) (Non SR item)

250

265

66250

... More
code350 - MS Outdoor Stand ( LABOUR WORK ) (Non SR item)

250

155

38750

... More
code351 - Library - Desk and Bench Providing and supplying Desk bench with shelf and with Bench with back - , made up of MS squar pipe of 25mmX25mm , 16 gauge mig welded -Powder COated . Top - Pre laminated board With 2mm Pvc Edge Bind - Bench size - 48" X 15" X 30" & Bench Size:- 48" X 14" X 18" -(Non SR item)

500

9900

4950000

... More
code352 - Seminar Podium Dias Providing & Fixing of Dias tables with labor charges and where ever necessary complete as per the instructions given by the engineer in-charge. ---- ---- etc complete with all lead and lift as per detailed specification and directions of the Engineer incharge. -(Non SR item)

4

16500

66000

... More
code353 - Book Shelf in Library Providing & supplying Bookshelf with carcass made of 18mm MR PLY finished with 1mm Laminate(suede finish) with 2 No.glass Shutters MADE OF 8MM CLEAR glass with ply fratne made of 18mm PLY with 1mm Laminate and 2 No Lower: shutters made of 18mm thk MR ply finished in laminate. It includes vertical and horizontal partitions made of 18mm thk ply as per design All exposed surfaces are finished in 1mm thk laminate(suede finish) with all edges covered with matching PVC edgeband including all necessary Hardware and accessories including handles,auto-closing hinges,locks etc.All internal surfaces finished in 0.8mm thk liner laminate. (Non SR) Size in mm: 1800W X 1800HX450D - (Non SR item)

40

30000

1200000

... More
code354 - Faculty Chairs Providing and Supplying Executive chairs of superior quality made up of ss/fibre frame with adjustable height, Cantilever support cushion with leather finish for resting No including transportation, loading, unloading, fixing labhour & all other charges etc.., as per the direction of Engineer in-charge. (Non SR)

4

20900

83600

... More
code355 - Providing and Supplying Computer chairs of superior quality made up of metal frame with adjustable height, Cantilever support cushion with fabric finish for resting, including transportation, loading, unloading, fixing labhour & all other charges etc.., as per the direction of Engineer in-charge. (Non SR)

140

6600

924000

... More
code356 - Computer Table Providing and Supplying Computer Table of 1000X600X750MM - Top:-18mm Bsl Pre Laminated Board With 2mm Pvc Edge Bind , Gabel Ends:- 18mm Bsl Pre Laminated Board With 0.8mm Pvc Edge Bind, telescopic Channel:- ‘’Hafele’’ &‘’Ebco (Brand), Keyboard Slide (250mm)+(30kgs Load Capacity), Levelers/Bushes Provided Wherever Necessary - (Non SR item)

140

7200

1008000

... More
code357 - Seminar chairs Providing and Supplying seminar Chairs with ; Arm Style - Half Pad, Back Type - perofrated Sheet 20 Gauge, Mig Welded , Black Powder coated, 18 mm BSL pre laminated board with 2mm PVC edge bend , Clamp Pad 18"X12" (Non SR )

800

3900

3120000

... More
code358 - Interactive Board S6-Note Book screen SCREEN:The screen has a foldable construction with two halves. Each half is upholstered on theoutside and has a whiteboard marker screen on the inside. The main structure for the screen is made from 18mm thk Medium density fibreboard. Whiteboard Laminate is pasted on 12mm thk Medium density fibreboard. This is then press-fitted onto the main structure. The outer side is covered using multiple layers of 12mm PU Slab- stock foam to achieve the convex shape, and upholstered using foam laminated fabric. One half has a diamond quilt while the other has a plain finish. The Screen is provided with a boundary of leatherette on the Laminate side. Both halves of the screen are connected using fabric hinge. The Screen is provided with marke...-pen holder made of fabric. LEGS: The screen rests on a leg frame structure made using 5mm thk Hot Rolled Steel Plates (As per TS:2062) and Epoxy Polyester Powder Coated (DFT 40-60 microns). The foot-block is made of FSC- certified seasoned Teak-Wood finished with a clear matt coat of PU Lacquer. CASTORS: Nylon Swivel Castors of 025 are fixed to the ot blocks to provide mobility. - Non Schedule Item

4

83150

332600

... More
code359 - Lift Work , Design, supplying, erecting testing and commissioning of - passenger/ Bed-cum-passenger hospital lift with speed of 1mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 V 3 phase 50 cycles AC supply, powder coated / Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED car illumination, emergency light, intercom and fan as desired by the user, central opening / side opening door with or without attendant operation, 7 segment display buttons, call register indicator, fireman drive, SS handrails inside car, full length infrared curtain in car door, automatic rescue device with batteries, voice announcing in regional / international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc., Page No. 1, SI. No.14 Part-II, 14.4 Without Machine Room-SS Finish, 14.4.4 - 13 Passengers

4

1983190

7932760

... More
code360 - Providing 4kg Fire Extinguisher Mono Ammonium Phosphate Powder 50, Stored Pressure Type, Pressure Gauge, Gross Weight 6.9 Kg, empty weight 2.9 Kg, Can Height 440MM, Diameter 140MM, Discharge Time less than 13 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 4 meters, applicable on Class A,8, C and electrically started Fire, A Rating 2A, 8 Rating 218, Can construction : Deep drawn & Co., Mig welded, valve Construciton : Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy Polyster power coating, Sheet metal thickness: 1.60MM, 5 years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete IS 15683, CE Approved. Make- ANDEX/CEASEFIRE/MINIMAX - Page No. 1, SI. No.15.3 Part-III

30

5266

158004

... More
code361 - Supply and instalation on of submersible borewell motor pumps.The unit rate shall include all materials including accessories,labour, equipment, tools and other incidental costs like testing ,handling, transporting, safe storage, etc. required to completethe supply.Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour. Complete as per specification and as per direction of enginner

1

350000

350000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.