Karnataka Housing Board Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Karnataka Housing Board - KHB Tender

Civil And Construction
Building Construction
Opening Date13 Mar 2024
Closing Date28 Mar 2024
Tender Amount₹ 1,08,05,612.97 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - KSRB 5.2-3: Providing and constructing granite/trap/basalt size stone masonry in foundtaion with cement mortar 1:6 edges of stones chistle dressed in courses not less than 15 cm high, bond stones at 2 Mtr apart in each course including cost of materials, labour curing complete as per specifications. KBS 5.1.13 (VOL-6 PG-65/81 . ITEM NO - 33.11)

7.34

5928

43516.5112

... More
code05 - Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. (VOL-1 PG-7 . ITEM NO - 1.80)

6.53

488

3188.0766

... More
code06 - GROUND FLOOR / DPC: 1:3:6 Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (VOL-1- PG-15 . ITEM NO - 2.1.4)

2.83

6403

18121.9333

... More
code07 - FIRST FLOOR / DPC: 1:3:6 Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (VOL-1- PG-16 . ITEM NO - 2.5.2)

0.73

6467

4721.3115

... More
code08 - SECOND FLOOR / DPC: 1:3:6 Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (VOL-1- PG-15 . ITEM NO - 2.1.4

1.69

6531

11038.3702

... More
code09 - TERRACE / DPC: 1:3:6 Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (VOL-1- PG-15 . ITEM NO - 2.1.4

13.9

6595

91679.118

... More
code10 - GROUND FLOOR Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (VOL-1- PG-16 . ITEM NO - 2.5.2)

7.65

10572

80879.166

... More
code11 - FIRST FLOOR Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (VOL-1- PG-16 . ITEM NO - 2.5.2)

8.01

10678

85532.0616

... More
code12 - SECOND FLOOR Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (VOL-1- PG-16 . ITEM NO - 2.5.2)

3.6

12221

43998.228

... More
code13 - SF ROOF BEAM Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (VOL-1- PG-16 . ITEM NO - 2.5.2)

4.84

11502

55673.6004

... More
code14 - SF ROOF SLAB Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (VOL-1- PG-16 . ITEM NO - 2.5.2)

21.66

10783

233578.8408

... More
code15 - SF LINTEL Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (VOL-1- PG-16 . ITEM NO - 2.5.2)

1.93

11502

22200.4233

... More
code16 - SF CHEJJA Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (VOL-1- PG-16 . ITEM NO - 2.5.2)

0.6

10424

6254.652

... More
code17 - SF STAIRCASE Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (VOL-1- PG-16 . ITEM NO - 2.5.2)

4.22

10783

45507.9736

... More
code18 - SF HEADROOM COLUMN Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (VOL-1- PG-16 . ITEM NO - 2.5.2)

8.06

12341

99472.9736

... More
code19 - HEADROOM ROOF BEAM Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (VOL-1- PG-16 . ITEM NO - 2.5.2)

3.06

11615

35543.6748

... More
code20 - ROOF SLAB SHUTTERING Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (VOL-1- PG-16 . ITEM NO - 2.5.2)

3.81

10889

41489.4141

... More
code21 - LINTEL SHUTTERING Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (VOL-1- PG-16 . ITEM NO - 2.5.2)

1.36

11615

15797.1888

... More
code22 - CHEJJA SHUTTERING Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (VOL-1- PG-16 . ITEM NO - 2.5.2)

0.09

10526

947.3958

... More
code23 - OHT COLUMN SHUTTERING Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (VOL-1- PG-16 . ITEM NO - 2.5.2)

1.35

12341

16661.106

... More
code24 - OHT SLAB SHUTTERING Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (VOL-1- PG-16 . ITEM NO - 2.5.2)

3.96

10889

43122.8556

... More
code25 - OHT ROOB BEAM SHUTTERING Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (VOL-1- PG-16 . ITEM NO - 2.5.2)

1.39

11615

16145.6562

... More
code26 - GROUND FLOOR Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)(VOL-1- PG-18 . ITEM NO - 2.11.A)

612

92

56389.68

... More
code27 - FIRST FLOOR Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)(VOL-1- PG-18 . ITEM NO - 2.11.A)

640.8

93

59632.848

... More
code28 - SECOND FLOOR Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)(VOL-1- PG-18 . ITEM NO - 2.11.A)

3685.16

93

346331.3368

... More
code29 - HEAD ROOM Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)(VOL-1- PG-18 . ITEM NO - 2.11.A)

3043.45

94

288823.405

... More
code30 - OHT Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (VOL-1- PG-18 . ITEM NO - 2.11.A)

943.38

94

89526.762

... More
code31 - GROUND FLOOR Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (VOL-2- PG-17 . ITEM NO - 6.32)

15.25

1349

20576.825

... More
code32 - SECOND FLOOR Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (VOL-2- PG-17 . ITEM NO - 6.32)

108.28

1376

149024.6812

... More
code33 - HEAD ROOM Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (VOL-2- PG-17 . ITEM NO - 6.32)

50.16

1389

69711.3648

... More
code34 - TERRACE Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (VOL-2- PG-17 . ITEM NO - 6.33)

159.6

1305

208432.812

... More
code35 - GROUND FLOOR Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(VOL-2- PG-17 . ITEM NO - 6.34)

26.1

1137

29678.832

... More
code36 - FIRST FLOOR Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(VOL-2- PG-17 . ITEM NO - 6.34)

21.12

1148

24256.1088

... More
code37 - SECOND FLOOR Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(VOL-2- PG-17 . ITEM NO - 6.34)

21.12

1159

24496.2432

... More
code38 - GROUND FLOOR Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.(VOL-2- PG-64 . ITEM NO - 9.30)

33.07

5487

181482.8688

... More
code39 - GROUND FLOOR Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.(VOL-2- PG-100 . ITEM NO -12.13.1)

0.08

101779

8142.356

... More
code40 - GROUND FLOOR Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.(VOL-2- PG-100 . ITEM NO -12.13.1)

0.22

102797

22615.3928

... More
code41 - SECOND FLOOR Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.(VOL-2- PG-100 . ITEM NO -12.13.1)

0.53

103815

55021.9712

... More
code42 - SECOND FLOOR Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. (VOL-2- PG-105 . ITEM NO -12.51)

4

1067

4269.64

... More
code43 - SECOND FLOOR Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick both side commercial. (VOL-2- PG-105 . ITEM NO -12.57.3)

9.6

3157

30307.68

... More
code44 - GROUND FLOOR Providing and supplying cupboard shutter with 19mm thick one side Architect recommended decorative laminate (1mm thick) and other side balancing lamination(preferably white) on factory pressed BWP grade marine ply as per IS 710 of approved brand complete as per direction of engineer in-charge.(Payment for providing and fixing auto closing hinges shall be paid separately)(VOL-2- PG-217 . ITEM NO -22.3)

25.74

3048

78476.112

... More
code45 - FIRST FLOOR Providing and supplying cupboard shutter with 19mm thick one side Architect recommended decorative laminate (1mm thick) and other side balancing lamination(preferably white) on factory pressed BWP grade marine ply as per IS 710 of approved brand complete as per direction of engineer in-charge.(Payment for providing and fixing auto closing hinges shall be paid separately)(VOL-2- PG-217 . ITEM NO -22.3)

77.22

3079

237782.7738

... More
code46 - SECOND FLOOR Providing and supplying cupboard shutter with 19mm thick one side Architect recommended decorative laminate (1mm thick) and other side balancing lamination(preferably white) on factory pressed BWP grade marine ply as per IS 710 of approved brand complete as per direction of engineer in-charge.(Payment for providing and fixing auto closing hinges shall be paid separately)(VOL-2- PG-217 . ITEM NO -22.3)

77.22

3109

240137.2116

... More
code47 - SECOND FLOOR Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.(VOL-2- PG-105 . ITEM NO -12.58)

4

126

504.28

... More
code48 - SECOND FLOOR Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.(VOL-2- PG-105 . ITEM NO -12.59)

4

1170

4681.48

... More
code49 - SECOND FLOOR Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.(VOL-2- PG-105 . ITEM NO -12.59)

4

1105

4420.92

... More
code50 - SECOND FLOOR - Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete (VOL-2- PG-105 . ITEM NO -12.63)

4

136

546.32

... More
code51 - SECOND FLOOR - Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 100x58x1.90mm - (VOL-2- PG-107 . ITEM NO -12.74.2)

12

95

1147.2

... More
code52 - SECOND FLOOR - Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete - (VOL-2- PG-105 . ITEM NO -12.62)

4

248

995.96

... More
code53 - GROUND FLOOR - Providing and fixing stainless steel 304 grade soft closing hinges with two hole fixing & 165 degrees turning option for Wardrobe, Doors, Kitchen & other utilities of reputed make with screws etc. complete as per directions of Engineer- in-charge. - (VOL-2- PG-218 . ITEM NO -22.12)

72

231

16686

... More
code54 - FIRST FLOOR - Providing and fixing stainless steel 304 grade soft closing hinges with two hole fixing & 165 degrees turning option for Wardrobe, Doors, Kitchen & other utilities of reputed make with screws etc. complete as per directions of Engineer- in-charge. - (VOL-2- PG-218 . ITEM NO -22.21)

216

234

50559.12

... More
code55 - SECOND FLOOR - Providing and fixing stainless steel 304 grade soft closing hinges with two hole fixing & 165 degrees turning option for Wardrobe, Doors, Kitchen & other utilities of reputed make with screws etc. complete as per directions of Engineer- in-charge. - (VOL-2- PG-218 . ITEM NO -22.21)

216

236

51060.24

... More
code56 - GROUND FLOOR Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete. (VOL-2- PG-105 . ITEM NO -12.62)

36

244

8787.96

... More
code57 - FIRST FLOOR Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete. (VOL-2- PG-105 . ITEM NO -12.62)

108

246

26627.4

... More
code58 - SECOND FLOOR Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete. (VOL-2- PG-105 . ITEM NO -12.62)

108

248

26890.92

... More
code59 - GROUND FLOOR Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete. (VOL-2- PG-105 . ITEM NO -12.63)

18

133

2410.2

... More
code60 - FIRST FLOOR Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete. (VOL-2- PG-105 . ITEM NO -12.63)

48

135

6491.52

... More
code61 - SECOND FLOOR Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete. (VOL-2- PG-105 . ITEM NO -12.63)

48

136

6555.84

... More
code62 - GROUND FLOOR Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.(VOL-2- PG-64 . ITEM NO - 9.3)

24.3

5487

133354.512

... More
code63 - FIRST FLOOR Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.(VOL-2- PG-64 . ITEM NO - 9.3)

72.9

5542

404064.288

... More
code64 - SECOND FLOOR Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.(VOL-2- PG-64 . ITEM NO - 9.3)

72.9

5597

408065.04

... More
code65 - SECOND FLOOR Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). (VOL-2- PG-110 . ITEM NO - 12.9)

16.65

7074

117794.421

... More
code66 - HEAD ROOM Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). (VOL-2- PG-110 . ITEM NO - 12.9)

2.78

7144

19860.598

... More
code67 - SECOND FLOOR Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). (VOL-2- PG-109 . ITEM NO - 12.85)

2.88

6008

17304.1344

... More
code68 - SECOND FLOOR Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(VOL-2- PG-41 . ITEM NO - 8.4.1)

92.4

339

31355.016

... More
code69 - TERRACE Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(VOL-2- PG-41 . ITEM NO - 8.4.1)

52.49

342

17986.7483

... More
code70 - GROUND FLOOR Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(VOL-2- PG-41 . ITEM NO - 8.2.1)

57.81

303

17565.5685

... More
code71 - FIRST FLOOR Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(VOL-2- PG-41 . ITEM NO - 8.2.1)

21.12

306

6481.5168

... More
code72 - SECOND FLOOR Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(VOL-2- PG-41 . ITEM NO - 8.2.1)

241.59

309

74875.9887

... More
code73 - HEAD ROOM Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(VOL-2- PG-41 . ITEM NO - 8.2.1)

50.83

312

15908.2651

... More
code74 - SECOND FLOOR Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufracturer, over the plastered wall surface to prepare the surface even and smooth complete as per specification and as per directions of Engineer in charge.(VOL-2- PG-50 . ITEM NO -8.51)

333.99

105

35088.9894

... More
code75 - HEAD ROOM Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufracturer, over the plastered wall surface to prepare the surface even and smooth complete as per specification and as per directions of Engineer in charge.(VOL-2- PG-50 . ITEM NO -8.51)

75.79

106

8040.5611

... More
code76 - GROUND FLOOR Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(VOL-2- PG-42 . ITEM NO -8.9)

133.5

396

52939.425

... More
code77 - FIRST FLOOR Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(VOL-2- PG-42 . ITEM NO -8.9)

106.8

400

42775.536

... More
code78 - SECOND FLOOR FLOOR Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(VOL-2- PG-42 . ITEM NO -8.9)

178.8

404

72321.024

... More
code79 - HEAD ROOM Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(VOL-2- PG-42 . ITEM NO -8.9)

432.84

408

176793.498

... More
code80 - SECOND FLOOR Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(VOL-2- PG-47 . ITEM NO -8.34.3)

19.53

52

1025.9109

... More
code81 - Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(VOL-2- PG-48 . ITEM NO -8.4)

19.53

120

2359.6146

... More
code82 - SECOND FLOOR Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(VOL-2- PG-47 . ITEM NO -8.34.1)

21.6

55

1202.688

... More
code83 - GROUND FLOOR Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50grams/litre of approved brand and manufracture, including applying addition coats wherever required to achieve even shadeand colour.Twocoatsas per specifications and as per directions of Engineerin charge.(VOL-2- PG-50 . ITEM NO -8.54.2)

57.81

113

6549.873

... More
code84 - FIRST FLOOR Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50grams/litre of approved brand and manufracture, including applying addition coats wherever required to achieve even shadeand colour.Twocoatsas per specifications and as per directions of Engineerin charge.(VOL-2- PG-50 . ITEM NO -8.54.2)

21.12

114

2416.7616

... More
code85 - SECOND FLOOR Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50grams/litre of approved brand and manufracture, including applying addition coats wherever required to achieve even shadeand colour.Twocoatsas per specifications and as per directions of Engineerin charge.(VOL-2- PG-50 . ITEM NO -8.54.2)

241.59

115

27920.5563

... More
code86 - TERRACE Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50grams/litre of approved brand and manufracture, including applying addition coats wherever required to achieve even shadeand colour.Twocoatsas per specifications and as per directions of Engineerin charge.(VOL-2- PG-50 . ITEM NO -8.54.2)

50.83

116

5931.861

... More
code87 - GROUND FLOOR Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(VOL-2- PG-46 . ITEM NO -8.31)

133.5

183

24475.89

... More
code88 - FIRST FLOOR Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(VOL-2- PG-46 . ITEM NO -8.31)

106.8

185

19776.156

... More
code89 - SECOND FLOOR Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(VOL-2- PG-46 . ITEM NO -8.31)

178.8

187

33437.388

... More
code90 - TERRACE FLOOR Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(VOL-2- PG-46 . ITEM NO -8.31)

432.84

188

81737.5056

... More
code91 - SECOND FLOOR Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm. (VOL-2- PG-61 . ITEM NO -9.17.2)

83.36

1234

102904.5856

... More
code92 - Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.(VOL-2- PG-63 . ITEM NO -9.24)

22.16

3025

67049.2904

... More
code93 - HEAD ROOM Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.(VOL-2- PG-69 . ITEM NO -10.2)

36

347

12527.28

... More
code94 - GROUND FLOOR Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.(VOL-2- PG-65 . ITEM NO -9.39)

66.68

1492

99517.8996

... More
code95 - GROUND FLOOR Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.(VOL-2- PG-86 . ITEM NO -11.34.B)

105.12

188

19814.0688

... More
code96 - SECOND FLOOR Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.(VOL-2- PG-86 . ITEM NO -11.34.B)

410.13

192

78851.5938

... More
code97 - SECOND FLOOR GRILL DUCT Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.(VOL-2- PG-86 . ITEM NO -11.34.B)

157.95

194

30664.413

... More
code98 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(VOL-2- PG-85 . ITEM NO -11.28)

161.28

593

95734.1952

... More
code99 - GROUND FLOOR Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis)(VOL-2- PG-150 . ITEM NO -15.7)

114

633

72213.3

... More
code100 - FIRST FLOOR Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis)(VOL-2- PG-150 . ITEM NO -15.7)

114

639

72934.92

... More
code101 - SECOND FLOOR Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis)(VOL-2- PG-150 . ITEM NO -15.7)

114

646

73657.68

... More
code102 - TERRACE Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis)(VOL-2- PG-150 . ITEM NO -15.7)

412.59

652

269194.3455

... More
code103 - FIRST FLOOR Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.(VOL-2- PG-149 . ITEM NO -15.1)

90.08

849

76561.6944

... More
code104 - SECOND FLOOR Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.(VOL-2- PG-149 . ITEM NO -15.1)

90.08

858

77319.2672

... More
code105 - Providing and laying flooring with burnt stone slabs 10 cms thick rough chistle dressed on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3,including cost of materials, mortar, labour, curing complete as per specifications.(VOL-2- PG-63 . ITEM NO -9.27)

6

2459

14757.84

... More
code106 - Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(VOL-2- PG-82 . ITEM NO -11.16.2)

5852

155

912619.4

... More
code107 - Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.(VOL-2- PG-26 . ITEM NO -7.38)

266

602

160288.94

... More
code108 - Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(VOL-2- PG-77 . ITEM NO -11.5.1)

4.2

4750

19952.982

... More
code109 - INTERNAL PLUMBING - Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer. (VOL-2- PG-133 . ITEM NO -14.7A)

8

4244

33957.04

... More
code110 - Providing and fixing unplasticised PVC connection pipe with brass unions : 20mm normal bore.(VOL-2- PG-118 . ITEM NO -13.8.2.2)

8

113

906.4

... More
code111 - Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0cm X 4.0 cm with all fitting arrangements & all necessary accessories complete. (VOL-2- PG-128 . ITEM NO -13.63)

2

251

502.64

... More
code112 - Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fitting including fixing the pipe with clamps at 1.00m spacing. This including jointing of pipes & fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.(20 MM NOMINAL DIA PIPES).(VOL-2- PG-122 . ITEM NO -13.32)

5

390

1951.85

... More
code113 - Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fitting including fixing the pipe with clamps at 1.00m spacing. This including jointing of pipes & fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.(25 MM NOMINAL DIA PIPES). (VOL-2- PG-122 . ITEM NO -13.32)

10

491

4913.1

... More
code114 - Water purification plants: Providing, Installation and Commissioning of automatic Water purification plant (RO+UF) with all accessories piping, product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. (Ref- detailed specification enclosed seperatly). Note:- 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BSI /NFS standards,with BSI / NFS mark . 3. Tenders to be invited for procurement. 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note : Refer the ANNEXURE : F for Detailed Specification of Each components--FOR 150 LPH : CABIN TYPE. (VOL-5- PG-247 . ITEM NO -21.1)

1

135960

135960

... More
code115 - COMPOUND WALL - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work (UNI SR Volume-1) In all kinds of soils Depth upto 3 m. (VOL-1- PG-8 . ITEM NO -1.14.1)

44.13

105

4636.2978

... More
code116 - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work (UNI SR Volume-1)(VOL-1- PG-8 . ITEM NO -1.13)

18.91

372

7050.7826

... More
code117 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates(VOL-1- PG-15 . ITEM NO -2.1.4)

7.65

6403

48986.8515

... More
code118 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (VOL-1- PG-7 . ITEM NO -1.9)

63.04

273

17271.6992

... More
code119 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Compound wall footing. (VOL-1- PG-15 . ITEM NO -2.2.3)

4.86

7048

34254.1062

... More
code120 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Compound wall plinth beam. (VOL-1- PG-15 . ITEM NO -2.2.3)

8.79

9789

86046.3648

... More
code121 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Compound wall gate footing. (VOL-1- PG-15 . ITEM NO -2.2.3)

1.35

7048

9515.0295

... More
code122 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Compound wall column upto plinth. (VOL-1- PG-15 . ITEM NO -2.2.3)

0.12

11094

1331.3208

... More
code123 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Compound wall curtain wall raft. (VOL-1- PG-15 . ITEM NO -2.2.3)

6.59

7178

47307.5671

... More
code124 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Compound curtain wall . (VOL-1- PG-15 . ITEM NO -2.2.3)

4.4

7178

31586.236

... More
code125 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. for Compound column.(VOL-1- PG-16 . ITEM NO -2.5.2)

2.4

11982

28757.016

... More
code126 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. for Compound gate column.(VOL-1- PG-16 . ITEM NO -2.5.2)

0.85

11982

10184.7765

... More
code127 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.-Brick work -(VOL-2- PG-17 . ITEM NO -6.33)

219.75

1267

278627.6175

... More
code128 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregate. Coping.(VOL-1- PG-15 . ITEM NO -2.1.4)

9.34

6403

59808.7834

... More
code129 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Block work .(VOL-2- PG-42 . ITEM NO -8.8)

674.84

382

257876.6092

... More
code130 - Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)(VOL-1- PG-18 . ITEM NO -2.11.a)

1462.2

92

134727.108

... More
code131 - Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.-(Gate)- (VOL-2- PG-84 . ITEM NO -11.52.2)

420

140

58833.6

... More
code132 - Finishing with Epoxy paint (two coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Enginer-in-charge.(VOL-2- PG-47 . ITEM NO -8.36.1)

8.4

181

1522.752

... More
code133 - ELECTRICAL Supplying heavy gauge PVC conduit pipe …….dia confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20mm dia 2mm thick

15

69

1035

... More
code134 - Supplying heavy gauge PVC conduit pipe …….dia confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25mm dia 2mm thick

100

81

8100

... More
code135 - Supplying heavy gauge PVC conduit pipe …….dia confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 32mm dia 2.5mm thick

5

106

530

... More
code136 - Supplying heavy PVC condiuit pipe ……mm dia ......mm thick confirming to IS 2509 woth suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary - 19/20mm dia 2mm thick

100

66

6600

... More
code137 - Supplying heavy PVC condiuit pipe ……mm dia ......mm thick confirming to IS 2509 woth suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary - 25mm dia 2mm thick

229

78

17862

... More
code138 - Supplying heavy PVC condiuit pipe ……mm dia ......mm thick confirming to IS 2509 woth suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary - 32mm dia 2.5mm thick

5

103

515

... More
code139 - Supplying heavy gauge PVC Conduit Pipe ….dia …..mm thick with suitable size bends, metal junction boxes adhesive paste etx., by groove cutting in the wall and fixing by using U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.-19/20mm dia 2mm thick.

80

68

5440

... More
code140 - Supplying heavy gauge PVC Conduit Pipe ….dia …..mm thick with suitable size bends, metal junction boxes adhesive paste etx., by groove cutting in the wall and fixing by using U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary-25mm dia 2mm thick

90

79

7110

... More
code141 - Supplying heavy gauge PVC Conduit Pipe ….dia …..mm thick with suitable size bends, metal junction boxes adhesive paste etx., by groove cutting in the wall and fixing by using U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.-32mm dia 2.5mm thick

5

99

495

... More
code142 - Supplying and fixing PVC/metal conduit deep junction box -19/20mm junction box

1

49

49

... More
code143 - Supplying and fixing PVC/metal conduit deep junction box- 25mm junction box

1

56

56

... More
code144 - Supplying and fixing PVC/metal conduit deep junction box-32mm junction box

1

61

61

... More
code145 - Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing the wall up to wall surface complete.- up to 50mm conduit in brick wall

2

29

58

... More
code146 - Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing the wall up to wall surface complete.- up to 50mm conduit CC floor

2

69

138

... More
code147 - Supplying PVC/Gi Flexible conduit pipe.. Mm dia fxing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddies at an interval of 300mm using NF screws on the either end of the pipe terminated completely.-20mm

1

19

19

... More
code148 - Supplying PVC/Gi Flexible conduit pipe.. Mm dia fxing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddies at an interval of 300mm using NF screws on the either end of the pipe terminated completely.-25mm

1

22

22

... More
code149 - Supplying PVC/Gi Flexible conduit pipe.. Mm dia fxing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddies at an interval of 300mm using NF screws on the either end of the pipe terminated completely.-32mm

1

29

29

... More
code150 - Supply and Fixing "S" Hook made out of 14mm dia M.S Rod.

1

53

53

... More
code151 - Suppling and Fixing M.S Rafter Clamp Set Made out of M.S Flat & 14mm M.S rod.

1

160

160

... More
code152 - Supplyin and Fixing Metal Fan Box with Round Hook.

17

117

1989

... More
code153 - WIRES & CABLES -Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0sqmm (Earthwire) FRLSmultistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point up to 3Mtr from tapping point to out let via switch

5

269

1345

... More
code154 - Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0sqmm (Earthwire) FRLSmultistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Medium point above 3mtr up to 6Mtr from tapping point to out let via switch

20

379

7580

... More
code155 - Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0sqmm (Earthwire) FRLSmultistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Above 6Mtr up to 10Mtr from tapping Point to out let via switch

35

555

19425

... More
code156 - Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0sqmm (Earthwire) FRLSmultistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches

20

677

13540

... More
code157 - Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0sqmm (Earthwire) FRLSmultistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches

5

989

4945

... More
code158 - Wiring for lighting/Power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper With Low conductor resistance single core wire in open or conceanled system of wiring with specified-1.5 sqmm

400

26

10400

... More
code159 - Wiring for lighting/Power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper With Low conductor resistance single core wire in open or conceanled system of wiring with specified-2.5 sqmm

840

42

35280

... More
code160 - Wiring for lighting/Power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper With Low conductor resistance single core wire in open or conceanled system of wiring with specified-4 sqmm

490

63

30870

... More
code161 - Wiring for lighting/Power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper With Low conductor resistance single core wire in open or conceanled system of wiring with specified-6 sqmm

40

92

3680

... More
code162 - Wiring for lighting/Power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper With Low conductor resistance single core wire in open or conceanled system of wiring with specified-10 sqmm

1

167

167

... More
code163 - Wiring for lighting/Power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper With Low conductor resistance single core wire in open or conceanled system of wiring with specified-16 sqmm

1

318

318

... More
code164 - Supplying and drawing flexible Multicore Cable Manufactured with electrolytic grade copper with flexible copper with low conductor resistance confirming to table 3class 5 of IS:8130-1984 and (virgin) PVC insulation and sheathed suitable for working voltage upto 1100Volts with specified IS-694:1990 & confirming to the attached-2c x 1.5Sqmm

1

53

53

... More
code165 - Supplying and drawing flexible Multicore Cable Manufactured with electrolytic grade copper with flexible copper with low conductor resistance confirming to table 3class 5 of IS:8130-1984 and (virgin) PVC insulation and sheathed suitable for working voltage upto 1100Volts with specified IS-694:1990 & confirming to the attached-3c x 1.5Sqmm

1

72

72

... More
code166 - SWITCHES, SOCKETS & ACCESSORIES Supplying and flush mounting powder coated metal / galvanised metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-1-2Way

20

138

2760

... More
code167 - Supplying and flush mounting powder coated metal / galvanised metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-3 Way

20

159

3180

... More
code168 - Supplying and flush mounting powder coated metal / galvanised metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-4-5Way

5

177

885

... More
code169 - Supplying and flush mounting powder coated metal / galvanised metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-6Way

5

220

1100

... More
code170 - Supplying and flush mounting powder coated metal / galvanised metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall- 8Way

12

261

3132

... More
code171 - Supplying and flush mounting powder coated metal / galvanised metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-10-12Way

10

319

3190

... More
code172 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.1 to 2 Module

20

137

2740

... More
code173 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. -Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.-3Module

20

161

3220

... More
code174 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.- 4Moudule

5

175

875

... More
code175 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.-6Moudule

5

234

1170

... More
code176 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.-8Moudule

12

284

3408

... More
code177 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.-12Moudule

10

344

3440

... More
code178 - `Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-6Amps one way Switch.

70

102

7140

... More
code179 - `Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-6Amps Two way Switch

2

166

332

... More
code180 - `Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-6Amps 3 way 5 pin universal Socket

20

171

3420

... More
code181 - `Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-Stepped Fan Regulator.

17

357

6069

... More
code182 - `Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-16 Amps SP switch with baklite

10

180

1800

... More
code183 - `Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-6Amps Bell push

1

177

177

... More
code184 - `Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-6/16Amps universal socket

10

236

2360

... More
code185 - `Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-Telephone socket

6

156

936

... More
code186 - `Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-TV socket

2

156

312

... More
code187 - `Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-RJ45/ I.O. outlet

4

337

1348

... More
code188 - Supplying 4mm thick plastic sheet with necessary nitches for fixing switches regulators etc., and fixing on existing wooden or metal box using N.F. screws.

50

8

400

... More
code189 - DISTRIBUTION BOARDS & ACCESSORIESSupplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' cure, indicator ON/OFF, energy cross-3 with Short circuit breaking cappacity of 10K and complete wiring as required. Confirming to IEC 60898.-6-32Amps SP

30

415

12450

... More
code190 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' cure, indicator ON/OFF, energy cross-3 with Short circuit breaking cappacity of 10K and complete wiring as required. Confirming to IEC 60898.-6-32Amps TPN

1

1717

1717

... More
code191 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' cure, indicator ON/OFF, energy cross-3 with Short circuit breaking cappacity of 10K and complete wiring as required. Confirming to IEC 60898.-40Amps TPN

2

3044

6088

... More
code192 - Supplying and fixing regular MCB Distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG M.S enclosure.-12Way SP & N

1

2329

2329

... More
code193 - Supplying and fixing regular MCB Distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG M.S enclosure.-8Way TP & N

1

6091

6091

... More
code194 - Supplying fxing and wiring Earth Leakage Miniature Circuit Breaker [RCCB] 240/450V upto 300mA sensitvity on existing wood/panel -16-25 Amps 2 pole

1

4277

4277

... More
code195 - Supplying fxing and wiring Earth Leakage Miniature Circuit Breaker [RCCB] 240/450V upto 300mA sensitvity on existing wood/panel -32-40 Amps 2 pole

4

5147

20588

... More
code196 - LIGHT, CEILING & EXHAUST FANS FITTINGS Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.-LED light fitting 1 x 2' - 9/10 W

5

551

2755

... More
code197 - LIGHT, CEILING & EXHAUST FANS FITTINGS Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.-LED light fitting 1 x 4' - 20/22 W

40

690

27600

... More
code198 - Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition -LED square or round down light 5-6W

5

571

2855

... More
code199 - Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition -LED square or round down light 15-18W

15

885

13275

... More
code200 - Supplying & fixing of Surface mounting type retrofit type -LED tube ....... W comprising of LED linear source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.-18W-20W (T8)

4

702

2808

... More
code201 - Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance ofcomplete luminaire IK08. Power Factor 0.9 with mains,Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatiblefor pole mauling with outer dia of 40mm to 50mm. UniversalVoltage driver to operate wide voltage range from 100 V to 270V50/60Hz application. Compliance to IS 10322/ IEC 60598,LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensureease of maintenance at the sight site location withminimized minimal tools. LED Light fixture with ....... W SystemPower consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facilityac credited by NABL / CPRI & any Government certifiedagency & Design & Development facility certified by ISO9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/-LED Floodlight 150W

2

12490

24980

... More
code202 - FANS & AIR CONDITIONERS Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete.-12" Sweep (300 mm)

2

2969

5938

... More
code203 - Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over andambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as perIS:374/1979 with latest amendment, 2 year manufacturer Warranty.48" Sweep 5 Star (1200 mm)

17

2677

45509

... More
code204 - Supplying wall mounting fan suitable to operate at singlephase 230v AC. supply.-300 mm Sweep

3

2492

7476

... More
code205 - GEYSERS, HEATERS & SOLAR WATER HEATERS Supplying.....litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate. 2kW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting. - 25 L

3

10242

30726

... More
code206 - Erection charges for fixing a ... litres capacity wall mounting electric geysers using bolts, flat at one end nut and washers at the other end for through bolts and nuts and washers with 150x450x600mm back plate and wiring complete with 15A 3 pin top. - upto 30 Liters

3

698

2094

... More
code207 - NETWORKING & TELECOMUNICATION Supplying and drawing UTP-CAT 6E LAN cable.

25

38

950

... More
code208 - Supplying and drawing PVC flexible one pair telepone unarmoured tinned copper cable.-2 Pair

26

21

546

... More
code209 - Supplying and drawing PVC flexible one pair telepone unarmoured tinned copper cable.-20 Pair

5

81

405

... More
code210 - Supplying and drawisng PVC insulated gas injected physical foam jelly flooded co-oxial TV cable.RG-6

25

44

1100

... More
code211 - Fixing all types and all capacities of fluorescent /False ceiling/spot light /CFL/LED fittings indoor on the wall/ ceiling/rafters/girders using 23/0.0076' twin twisted PVC insulated wires, required Nos of round blocks and clamps.-On wall / ceiling /Rafter / Girders

70

122

8540

... More
code212 - Fixing a Ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook wisth fan regulator to the existing board together wisth wupplying and fixing 5amps. Ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.

17

315

5355

... More
code213 - Fixing on e exhaust fan in the nitch already left in the wall with bolts and nuts and 5 amps. Ceiling rose wisth sufficient length of 23/0.0076 inch PVC insulated twincore wire.

5

492

2460

... More
code214 - Water purification plants: Providing, Installation and Commissioning of automatic Water purification plant (RO+UF) with all accessories piping, product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. (Ref- detailed specification enclosed seperatly). Note:- 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BSI /NFS standards,with BSI / NFS mark . 3. Tenders to be invited for procurement. 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note : Refer the ANNEXURE : F for Detailed Specification of Each components For 50 LPH : Cabin Type Vol-5 (pg no 247, I No 21.1.2)

3

46200

138600

... More
code215 - Smart Surveillance System (CCTV): using PTZ & Fixed cameras, OFC monitoring system, HMI etc., as per specification PTZ Camera Specification: Lens type: Auto focus with Optical Zoom of 30x, Digital Zoom +10x Pan Angle: 360 degree endless Tilt Angle: 210 degree with e-flip or higher Zoom : 30x Optical and 12x Digital Mode :Day and Night Image size: Full HD Streaming: High speed Weather Proof: IP 66 compliant Network Protocol: TCP/IP should be compliant of any other protocol required. Connectivity : Cat 6 / Optical fibre Ethernet: 10Base-T/100Base-TX(RJ45) Power source : both self powered and externally powered

2

70719

141439.2

... More
code216 - Smart Surveillance System (CCTV): using Fixed cameras, OFC monitoring system, HMI etc., as per specification Fixed Camera Specifications: Lens type: Bi focal auto iris with 10X digital zoom Mode :Day Night Image size: 720X486 (NTSC) Streaming: High speed Weather Proof: IP 66 compliant Network Protocol: TCP/IP should be compliant of any other protocol required. Connectivity : Cat 6 Optical fibre Ethernet 10Base t 100Base TX (RJ45) Power source : both self powered and externally powered

2

12586

25172.7

... More
code217 - Industrial Grade PC with latest specification

1

103672

103672.8

... More
code218 - HMI Monitor : 29"

1

25918

25918.2

... More
code219 - Erection, Installation and commissioning of CCTV Surveillance system PTZ Camera

2

1270

2541

... More
code220 - Erection, Installation and commissioning of CCTV Surveillance system Fixed Camera

2

1270

2541

... More
code221 - Supplying and drawing UTP-CAT 6E LAN cable.

400

39

15960

... More
code222 - Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 de Rock wool insulation with 22SWG Aluminium cladding. 300 L

3

73485

220455.9

... More
code223 - Supplying, installing, testing and commissioning of Diesel Generator set 62.5KVA/50kw with following specifications. Power rating as per standard reference condition as per-BS 5514/ISO 3046/ ISO 8528 & IS 1002/ISO 3046 Generator set specifications Engine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade), Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation Alternator: Alternator is suitable for operation at 1500 RPM, 415 V, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming to IS/IEC 60034-1. The Alternator is brush less type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have+/- 1.0% Voltage regulation (max) in static conditions- IP: 23 protections with insulation class F&H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lA for 'Load On' and 'Set Running', Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections.

1

673124

673124.55

... More
code224 - Supply, Erection, testing and commissioning of AMF panel suitable for 62.5 KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for A 4 pole contactor for alternator with thermal O/L relay,..... A 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, ....capacity bypass switch and frequency sensing, PCC 1301controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ kVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMF module by pass Mode, Battery charger unit with inbuilt Auto/Manual and Flat/Boost facility. The complete set shall have sufficient safety and adhere to NEC, NBC 2016, IEC, CPWD specifications, PCB norms and KSGEI Acts and Rules.

1

81656

81656.4



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.