Karnataka Housing Board Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Karnataka Housing Board - KHB Tender

Works
Civil And Construction
Opening Date3 Oct 2024
Closing Date4 Nov 2024
Tender Amount₹ 7,58,41,959.02 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

500

168

84000

... More
code05 - Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water, all materials, usage & all other appurtenances required to complete the work.

1771.2997

497

881575.86069

... More
code06 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates.

284.07

5947

1689421.104

... More
code07 - Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and Floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.

1536

123

190310.4

... More
code08 - Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately). Also includes cost of formwork. RCC Column Footing M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.

469.58

7185

3373941.6916

... More
code09 - Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement to be paid separately). Also includes cost of formwork. RCC Pedestal M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.

18.41

11309

208212.6816

... More
code10 - Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement to be paid separately). Also includes cost of formwork. RCC Retaining walls M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.

96.93

11309

1096255.0368

... More
code11 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement &dowel bars to be paid separately). Also cost includes Formwork, Centering and Scaffolding. RCC Column M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. GROUND FLOOR

141.99

11309

1605872.8224

... More
code12 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement &dowel bars to be paid separately). Also cost includes Formwork, Centering and Scaffolding. RCC Column M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. FIRST FLOOR

75.29

11422

860027.1294

... More
code13 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement &dowel bars to be paid separately). Also cost includes Formwork, Centering and Scaffolding. RCC Column M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. SECOND FLOOR

43.6

11537

503017.124

... More
code14 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & dowel bars to be paid separately). Also cost includes Formwork, Centering and Scaffolding. RCC Column M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. HEAD ROOM

7.63

11469

87515.2607

... More
code15 - Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken Floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) Also includes cost of formwork. RCC Plinth Beam M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.

94.76

9038

856529.0068

... More
code16 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement &dowel bars to be paid separately). Also cost includes Formwork, Centering and Scaffolding. RCC Lintel M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. GROUND FLOOR

20.29

11138

225998.136

... More
code17 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement &dowel bars to be paid separately). Also cost includes Formwork, Centering and Scaffolding. RCC Lintel M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. FIRST FLOOR

20.14

11249

226570.5692

... More
code18 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement &dowel bars to be paid separately). Also cost includes Formwork, Centering and Scaffolding. RCC Lintel M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. SECOND FLOOR

10.48

11362

119076.6944

... More
code19 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement &dowel bars to be paid separately). Also cost includes Formwork, Centering and Scaffolding. RCC Roof Beam M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. GROUND FLOOR

85.81

11496

986492.3544

... More
code20 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement &dowel bars to be paid separately). Also cost includes Formwork, Centering and Scaffolding. RCC Roof Beam M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. FIRST FLOOR

90.83

11611

1054645.296

... More
code21 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement &dowel bars to be paid separately). Also cost includes Formwork, Centering and Scaffolding. RCC Roof Beam M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. SECOND FLOOR

28.13

11727

329889.2303

... More
code22 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement &dowel bars to be paid separately). Also cost includes Formwork, Centering and Scaffolding. RCC Roof Slab M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. GROUND FLOOR

306.55

10777

3303913.1315

... More
code23 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement &dowel bars to be paid separately). Also cost includes Formwork, Centering and Scaffolding. RCC Roof Slab M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. FIRST FLOOR

226.79

10885

2468722.545

... More
code24 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement &dowel bars to be paid separately). Also cost includes Formwork, Centering and Scaffolding. RCC Roof Slab M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. SECOND FLOOR

89.26

10994

981356.5736

... More
code25 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement &dowel bars to be paid separately). Also cost includes Formwork, Centering and Scaffolding. RCC Plain Chajja M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. GROUND FLOOR

17.39

10094

175537.7902

... More
code26 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement &dowel bars to be paid separately). Also cost includes Formwork, Centering and Scaffolding. RCC Plain Chajja M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. FIRST FLOOR

16.26

10195

165772.6512

... More
code27 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement &dowel bars to be paid separately). Also cost includes Formwork, Centering and Scaffolding. RCC Plain Chajja M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. SECOND FLOOR

4.19

10297

43144.7233

... More
code28 - Providing and laying Cement concrete Flooring 40 mm thick with 20 mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a Floating coat of neat cement, including cement slurry complete. FLAGGING CONCRETE

109.2

473

51711.66

... More
code29 - Supplying, fitting and placing TMT FE550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. GROUND FLOOR

127442.67

93

11970689.9931

... More
code30 - Supplying, fitting and placing TMT FE550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. FIRST FLOOR

50318.92

94

4773755.9404

... More
code31 - Supplying, fitting and placing TMT FE550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. SECOND FLOOR

16772.34

95

1607125.6188

... More
code32 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc. complete as per specifications. GROUND FLOOR

1661.13

1375

2284884.315

... More
code33 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc. complete as per specifications. FIRST FLOOR

1892.15

1389

2628688.309

... More
code34 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc. complete as per specifications. SECOND FLOOR

657.58

1403

922683.377

... More
code35 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc. complete as per specifications. GROUND FLOOR

86.93

1159

100769.256

... More
code36 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc. complete as per specifications. FIRST FLOOR

66.48

1170

77834.1192

... More
code37 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc. complete as per specifications. SECOND FLOOR

12.75

1182

15076.875

... More
code38 - Fixing of door frame in an existing opening including embedding frame in Floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and Floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.

95

1066

101346

... More
code39 - Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. GROUND FLOOR

1.58

103755

163934.085

... More
code40 - Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. FIRST FLOOR

1.47

104793

154046.1657

... More
code41 - Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.SECOND ROOM

0.53

105841

56095.8572

... More
code42 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame all-round door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification. Ground Floor

72.27

4245

306796.9905

... More
code43 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame all-round door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification. First Floor

61.53

4287

263816.028

... More
code44 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame all-round door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification. Second Floor

23.31

4330

100943.4888

... More
code45 - Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In Charge. (Fixtures shall be paid for separately) Ground floor

54

737

39803.4

... More
code46 - Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In Charge. (Fixtures shall be paid for separately) Ground floor

10.8

738

7972.02

... More
code47 - Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In Charge. (Fixtures shall be paid for separately) First floor

48.6

744

36181.242

... More
code48 - Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In Charge. (Fixtures shall be paid for separately) Second floor

5.4

751

4060.368

... More
code49 - Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) Ground floor

21

2142

44982

... More
code50 - Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) First floor

15.12

2163

32710.9104

... More
code51 - Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) Second floor

1.68

2185

3670.884

... More
code52 - Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Ground Floor

75.3

6878

517954.815

... More
code53 - Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) First Floor

75.3

6947

523134.702

... More
code54 - Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Second Floor

36

7016

252605.16

... More
code55 - Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Ground floor

655.2

155

101818.08

... More
code56 - Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.

630

156

98878.5

... More
code57 - Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Second floor

226.8

158

35952.336

... More
code58 - Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. Ground Floor

199.01

1622

322843.9725

... More
code59 - Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. First Floor

256.22

1638

419808.7834

... More
code60 - Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. Second Floor

100.37

1654

166098.2982

... More
code61 - Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Ground Floor

697.25

2189

1526454.5625

... More
code62 - Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. First Floor

418.05

2211

924367.077

... More
code63 - Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Second Floor

123.6

2233

276029.7

... More
code64 - Providing and laying vitrified Floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Ground Floor

398.07

1202

478579.6575

... More
code65 - Providing and laying vitrified Floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. First Floor

748.04

1214

908322.5308

... More
code66 - Providing and laying vitrified Floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Second Floor

432.7

1226

530671.934

... More
code67 - Providing and laying Ceramic glazed Floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. Ground Floor

95.05

943

89722.4475

... More
code68 - Providing and laying Ceramic glazed Floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. First floor

75.28

953

71771.1992

... More
code69 - Providing and laying Ceramic glazed Floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. Second Floor

2.2

962

2118.424

... More
code70 - Providing skirting, dado, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with while cement slurry over rough plaster surface (excluding cost of rough plastered surface which should be measured and paid separately) using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications and direction of Engineer in charge. Size 15x15cms Ground Floor

192.3

1521

292574.835

... More
code71 - Providing skirting, dado, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with while cement slurry over rough plaster surface (excluding cost of rough plastered surface which should be measured and paid separately) using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications and direction of Engineer in charge. Size 15x15cms First floor

89.63

1536

137730.8358

... More
code72 - Providing skirting, dado, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with while cement slurry over rough plaster surface (excluding cost of rough plastered surface which should be measured and paid separately) using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications and direction of Engineer in charge. Size 15x15cms Second Floor

8.18

1552

12695.6054

... More
code73 - Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR INTERNAL PLASTERING

3413.67

267

914010.1425

... More
code74 - Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR INTERNAL PLASTERING

3253.12

270

879741.2416

... More
code75 - Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SECOND FLOOR INTERNAL PLASTERING

1390.96

273

379912.9048

... More
code76 - Providing 15 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR EXTERNAL PLASTERING

1659.85

309

514138.5375

... More
code77 - Providing 15 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR EXTERNAL PLASTERING

1482.5

312

463800.125

... More
code78 - Providing 15 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SECOND FLOOR EXTERNAL PLASTERING

1367.9

315

432229.042

... More
code79 - Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. FOR CEILING Ground floor

1876.2

221

415672.11

... More
code80 - Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. FOR CEILING First floor

1495.66

223

334683.8382

... More
code81 - Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. FOR CEILING Second floor

999.68

226

225927.68

... More
code82 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Ground floor

5013.88

105

526457.4

... More
code83 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. First floor

4592.12

106

486994.326

... More
code84 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Second floor

2100.53

107

224987.7683

... More
code85 - Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Interior walls and Ceiling Ground floor

5013.88

165

831802.692

... More
code86 - Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Interior walls and Ceiling First floor

4592.12

167

769455.6272

... More
code87 - Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Interior walls and Ceiling Second floor

2100.53

169

355472.6919

... More
code88 - Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. External wall Ground floor

1659.85

182

303254.595

... More
code89 - Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. External wall First floor

1482.5

184

273565.725

... More
code90 - Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. External wall Second floor

1367.9

186

254935.523

... More
code91 - Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Ground floor

71.88

144

10415.412

... More
code92 - Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. First floor

20.79

146

3042.6165

... More
code93 - Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Second floor

27.72

147

4097.2932

... More
code94 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. Flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. Ground floor

1656.6

192

318315.69

... More
code95 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. Flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. First floor

1656.6

192

318315.69

... More
code96 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. Flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. Second floor

792

192

152182.8

... More
code97 - Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Ground floor

75.3

145

10990.035

... More
code98 - Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. First floor

82.5

147

12161.325

... More
code99 - Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Second floor

36

148

5359.68

... More
code100 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the Floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.

270

593

160177.5

... More
code101 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the Floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.

270

599

161778.6

... More
code102 - Providing and fixing in position collapsible steel shutters with single or double leaf with vertical channel 20mmx10mmx2mm braced with iron flat iron diagonals 20mmx5mm size, with top and bottom rails of T iron sections of 40x40x6 mm with 38mm dia steel pulleys complete with bolts and nuts, locking arrangements, stoppers, handles on both sides with 7.5cms openings at 10 cms c to c applying a priming coat of red lead paint, cost of materials, labour, HOM of machinery complete as per specifications.

6.3

8689

54745.74

... More
code103 - Providing & fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter.

80

305

24444

... More
code104 - Weathering course to roofs using Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates. First Floor Roof

65.46

6724

440166.132

... More
code105 - Weathering course to roofs using Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates. Second floor Floor Roof

48.2

6725

324157.05

... More
code106 - Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. First Floor Roof

65.46

857

56154.861

... More
code107 - Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. Second floor Floor Roof

48.2

866

41761.926

... More
code108 - Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof including cost of material, labour, scaffolding etc as per specifications and as per directions of the Engineer-in-Charge.

114

60

6942.6

... More
code109 - Providing and fixing plaster mesh 200mm wide manufactured out of hot dipped galvanized iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications.

300

46

13860

... More
code110 - Providing and fixing oxidised M.S. double acting spring hinges with necessary screws etc. complete. 150mm

285

319

90972

... More
code111 - Providing and fixing chromium plated brass 100 mm mortise latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.

95

1104

104937

... More
code112 - Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete.

95

136

12967.5

... More
code113 - Providing and fixing bright finished brass hanging type Floor door stopper with necessary screws, etc. complete.

65

126

8190

... More
code114 - Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 8 mm thickness (weight not less than 20 kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications

84

1370

115101

... More
code115 - Providing and fixing anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868. Minimum anodic coating of grade AC 15) sub frame work for windows and ventilators with extruded built up standard tubular sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia and size (Dash fastener to be paid for separately) including cost of materials, labour, usage charges of machinery complete as per specifications.

625

414

259218.75

... More
code116 - WATER SUPPLY SYSTEM - Earth work excavation for pipelines/cables by mechanical means upto 600mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. All Kind of soils. Depth upto 1.50m

270

275

74277

... More
code117 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete Ground Floor 15 mm nominal dia Pipes

60

42

2520

... More
code118 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete Ground Floor PVC pipes 25mm dia, 10 kg/sqcm & class 5

150

50

7560

... More
code119 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete Ground Floor PVC pipes 32mm dia, 10 kg/sqcm & class 5

150

70

10552.5

... More
code120 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete Ground Floor PVC pipes 50mm dia, 10 kg/sqcm & class 5

150

106

15907.5

... More
code121 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete First Floor 15 mm nominal dia Pipes

30

191

5733

... More
code122 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete First Floor 25 mm nominal dia Pipes

150

333

50085

... More
code123 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete First Floor 32 mm nominal dia Pipes

200

420

84000

... More
code124 - Providing GM (copper alloy) wheel valves/ check valve confirming to IS 778/1990 Class-I with latest amendments No. 1 and with ISI mark screwed in bonnet integral seat inside, screw, rising spindle screwed female ends confirming to IS 554/ 1990 body hydraulically tested 1.50 HP seat hydraulically tested 1.00 HP. For 32 mm dia GM (Copper alloy) wheel valves/ check valve.

6

1404

8429.4

... More
code125 - Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 50 mm dia GM (Copper alloy) Gate valves

8

1345

10760.4

... More
code126 - Providing and fixing PTMT pillar cock of approved quality and colour. 15 mm nominal bore, 125 mm long foam Flow, weighing not less than 120 gms.

35

329

11539.5

... More
code127 - Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. Flushing cistern, including Flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fttings and fixtures complete, including cutting and making good the walls and Floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests.

15

5128

76923

... More
code128 - Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china Flushing cistern & C.P. Flush bend with fittings & C.I. brackets, 40 mm Flush bend, overFlow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and Floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid.

5

6275

31379.25

... More
code129 - Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern. One urinal basin with 5 litre white P.V.C. automatic flushing cistern

10

4676

46767

... More
code130 - White Vitreous China Angle back wash basin size 600 x 480 mm with single 15mm C.P. brass pillar tap

10

2689

26890.5

... More
code131 - Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete.

30

256

7686

... More
code132 - Providing and fixing PVC (S.W.R) Gully Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete.

10

363

3633

... More
code133 - Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.

24

520

12499.2

... More
code134 - Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

10

1281

12810

... More
code135 - Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 HDPE Grade PE80-PN6.0, 75mm dia

200

257

51450

... More
code136 - Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.

20

152

3045

... More
code137 - Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support tank.

10000

9

94500

... More
code138 - UNDER GROUND DRAINAGE - Earth work excavation for pipeline trenches in all kinds of by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of slumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata. Ordinary/soft rock (without requiring blasting) Depth upto 1.50 m.

162

275

44566.2

... More
code139 - Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes all-round to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: HDPE Grade PE80-PN6.0, 75mm dia

50

257

12862.5

... More
code140 - Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes all-round to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: HDPE Grade PE80-PN6.0,110mm dia

300

492

147735

... More
code141 - Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes all-round to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: HDPE Grade PE80-PN6.0, 160mm dia

300

1006

302085

... More
code142 - Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover

17

4447

75612.6

... More
code143 - Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..

9

5726

51540.3

... More
code144 - Providing and constructing “WIRE CUT BRICK MACHINEHOLE CHAMBERS” using Portland/Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber. Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Supplying and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Supplying and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de-watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm diaCirc. B M.H: Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.0 M depth & SFRC cover & frame.

1

25566

25566.45

... More
code145 - SUMP TANK - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth

12

107

1285.2

... More
code146 - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Depth exceeding 3m, but not exceeding 6m

36

122

4422.6

... More
code147 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

20.87

279

5828.991

... More
code148 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates

3.31

6288

20814.7695

... More
code149 - Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken Floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Floor slab

3.85

6639

25560.7275

... More
code150 - Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken Floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & formwork to be paid separately and include Additionalities for Formwork, Centering & Scaffolding) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For RCC walls

8.6

7303

62806.402

... More
code151 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement, dowel bars & formwork to be paid separately and includes Additionalities for Formwork, Centering & Scaffolding) M20 Design Mix Using 20 mm nominal size graded crushed coarse. aggregates

2.41

9958

24000.5393

... More
code152 - Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members wherever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)

1125.94

93

105759.5442

... More
code153 - Providing 20 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) fnished with a Floating coat of neat cement to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifcations and as per directions of Engineer-in-charge.

70.49

450

31752.2205

... More
code154 - Providing and fxing MS ladder between landings, 45 cms wide using angle iron of specifed sizes, 20mm MS bars at 25 cms. centre to centre, with necessary supports of same angle iron etc. as directed, including hand railing on both sides with 25mm dia. GI pipes with angle iron props at 2 mtrs. intervals and 0.5M heigh, including fxing in ground with CC 1:2:4 and two coats of anticorrosive bituminous paint etc. with all lead and lifts etc. complete with: MS angle 65x65x8mm.

1.8

4595

8272.53

... More
code155 - Providing and fxing MS inspection door of size 60 cms x 60 cms, including MS frame made of 50x50x6mm angle, shutters made of 3mm thick MS sheets, with hinges, locking arrangements at top etc. including painting with anticorrosive approved paint etc. complete including all lead and lifts etc.

2

2247

4494

... More
code156 - PUMPING WATER FROM SUMP TO OHT - Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confrming to ISI standards and its latest amendments. 5 HP, size 80x65 Head 23.50M, Discharge 600 LPM

1

22500

22500

... More
code157 - Supplying of LT UG cable having aluminum conductor PVC insulated, sheathed,galvanised, steel wire/steel tap armoured cable with PVC outer sheathing 1.1 KV class. I Class 'A' PVC Cable. 4 core 10 sqmm

80

118

9504

... More
code158 - Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes10 sqmm

1

7

7.65

... More
code159 - Supplying and fixing of heavy duty cable glands suitable or UG cable 1.1KV class (metal only) 25mm dia

1

86

86

... More
code160 - PUMP PANEL - Supplying……amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/ERP/DMC insulator which are mounted on powder coated 40x6 mm M.S flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc, complete. 100Amps 4x30x6mm Aluminum Strips

1

2214

2214

... More
code161 - Supplying and fixing Moulded Case Circuit breakers (MCCB) over the existing wood/panel board using necessary screws,bolts,nuts and wiring complete. Protection of Overload and short circuit with thermal Magnetic/Micro processed release and Earth Fault as per IS- 13947.(Icu =Ics) FOUR POLE Group A 125- 160Amps 25KA

1

8586

8586

... More
code162 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and wiring complete as required. Group 'A' 40-A TPN

1

1936

1936

... More
code163 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and wiring complete as required. Group 'A' 6-32Amps DP

1

1103

1103

... More
code164 - Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/manual reset facility suitable to mount on DN rail/flush mounting on panel board. Group A

1

8316

8316

... More
code165 - Supplying push button operated direct online starter with an anti weld silver cadmium oxide conductor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet or iron clad enclosure and fixing the same to suitable capacity wires for 400/440 volts 3 phase motor/single phase motor upto 5 HP.

1

1490

1490

... More
code166 - Supplying, fixing and wiring 3 phase Digital Ammmeter/Voltmeter

1

1280

1280

... More
code167 - Supplying, fixing and wiring electronic 10 to 40Amps three phase 4 wire class-1 Accuracy Energy Meter. Group A

1

5125

5125

... More
code168 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230v A.C.50Hz 12/24v D.C.

1

464

464

... More
code169 - Supplying & fixing of Caution / Danger name board as per drawing

1

163

163

... More
code170 - Fabricating supplying and mounting MS box made out 16 SWG suitable for floor/wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. 14SWG

9500

-

4085

... More
code171 - Fabricating supplying and mounting MS box made out 16 SWG suitable for floor/wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. 16SWG

13500

-

5130

... More
code172 - Fabricating supplying and mounting MS box made out 16 SWG suitable for floor/wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. Copper strip 8SWG

15

107

1615.5

... More
code173 - Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 15mm alround the cable.

15

103

1545

... More
code174 - Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.

15

78

1170

... More
code175 - Gun metal non return valve 50mm nominal bore vertical type

1

1219

1219

... More
code176 - Gun metal non return valve 65mm nominal bore vertical type

1

1945

1945

... More
code177 - BOREWELL TO SUMP TANK - Earth work excavation for pipelines/cables by mechanical means upto 600mm trench width, as per drawing and technical specifcations, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.

108

275

29710.8

... More
code178 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

108

279

30164.4

... More
code179 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete. PVC pipes 50mm dia, 10 kg/sqcm & class 5

100

106

10605

... More
code180 - Providing and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of Ductile Iron (DI) conforming ti IS-1865 with the latest amendments and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 with the latest amendments only. The stem sealing should be with toroidal sealing rings (minimum 2 " O " rings). Body and bonnet should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. For PN-10: (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) etc. complete sluice Valve of PN - 10.0 and 50mm

2

5811

11623.5

... More
code181 - Providing and fixing of Single/ Double chamber triple function tamper proof (Both the orifces to be housed in the single chamber) Air valves with Body and cover in Ductile cast iron of grade GGG 40/ 50. All internal parts such as float, shell with appurtenances., all cover bolts of austenitic alloy / SS 304 steel, DN 50 float of HOSTAFLON / SS 304 and gaskers and seals of EPDM. Epoxy powder coating (EP-P) inside and outside colour blue RAL5005. The valves should be designed for all the three functions i.e., 1. Large orifice for venting of large air volumes on start up. 2. Large orifice for intake of large air volumes. 3. Small orifice for discharge of pressurized air during operation. For PN10.0 etc. complete. For TP Air Valves of 80mm dia

2

29600

59201.1

... More
code182 - Providing and fxing gun metal non- return valve of approved quality (screwed end) : 50 mm nominal bore.

2

1429

2858.1

... More
code183 - BOREWELL DRILLING - Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fxing Casing pipes beyond 20 M (for fxing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fxed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test..

1

5552

5552.4

... More
code184 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the fnal depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete. Upto 50 Mtrs

25

388

9712.5

... More
code185 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the fnal depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete. Above 50 Mtrs and upto 100 Mtr.

25

487

12180

... More
code186 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the fnal depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete. Above100 Mtrs. and upto 150 Mtr.

25

517

12941.25

... More
code187 - Supply of ISI mark 175mm nominal bore, plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fxed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty.

25

2029

50741.25

... More
code188 - Supply and delivery of galvanized mild steel tubes of 6mtr standard length heavy duty (C Class) as per IS 1239 (Part-I) 1990 with latest amendments with ISI Mark (one end fitted with Heavy Duty collar and other end fitted with protective cover) 65mm )

15

3753

56306.25

... More
code189 - Providing, supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confrming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifcations,as per necessary ammendments and instructions of engineer incharge of work. 7.50 HP - 90 LPM @ 165 m = 15 STG Outlet Dia - 2.00"

1

42850

42850.5

... More
code190 - Providing and fxing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments.

1

157

157.5

... More
code191 - Providing and laying at site of work MS casing caps as per IS 1239 (part II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fxing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge.

1

172

172.2

... More
code192 - Supply and delivery at site wrought middle steel (galvanized) GI union confrming to IS 1239-II, 1991 with latest amendments if any. For 50 mm dia GI Union.

1

280

280.35

... More
code193 - Providing and construction of platform in CC 1:2:4 proportion using hard granite or basalt or trap jelly of 20mm and down size for India MarkII hand pump as per approved drawing enclosed to the S.R (UNICEF standard), including machine mixing, laying, tamping, curing and smooth finishing of exposed faces in CM 1:3 with necessary moulds, including earth work excavation with all leads of materials etc. complete.

1

4441

4441.5

... More
code194 - Supplying of Thermosetting Plastic i.e., Fiber Glass reinforced polyster sheet moulding compound(SMC) pump house with SMC door & canopy etc..., component as directed by the departmental offers.

1

12600

12600

... More
code195 - Supply and delivery at site of brand new best make pressure gauge bourdon type of size 63mm as per IS 778/1984 with ISI Mark and as per its latest amendments.

1

436

436.8

... More
code196 - Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x10 m2

182.88

294

53766.72

... More
code197 - Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG

30000

-

12000

... More
code198 - Supply, installing, testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type.

1

14962

14962.5

... More
code199 - Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specifcation, with testing of as per instructions of engineer incharge of work.

1

1312

1312.5

... More
code200 - Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box.

1

1312

1312.5

... More
code201 - Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. 32Amps

1

2041

2041.2

... More
code202 - Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrifcation and commissioning of the same at the location of respective pump sets.

1

577

577.5

... More
code203 - DEMOLISHION OF EXISTING BUILDING - Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) Flooring

142.21

1080

153650.7945

... More
code204 - Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge)

59.95

2547

152710.635

... More
code205 - Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer-in-charge.

59.95

763

45762.8325

... More
code206 - Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.

627.38

1768

1109333.316

... More
code207 - Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.

134.65

506

68146.365

... More
code208 - Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking to the appropriate disposal area as per direction of Engineer in-charge.

184.44

252

46478.88

... More
code209 - 19.13 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking to the appropriate disposal area as per direction of Engineer-in-charge.

126

98

12436.2

... More
code210 - Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials to the appropriate disposal area as per direction of Engineer-in-charge.

942.45

37

35624.61

... More
code211 - INTERNAL ELECTRIFICATION - PVC CONDUITS AND ACCESSORIES - SUB MAIN CIRCUIT / CIRCUIT MAINS Wiring for lighting/Power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper With Low conductor resistance single core wire in open or conceanled system of wiring with specified IS-694:1990 (a) 3/0.028 (3/22) mm (1.5 Sqmm Copper wire)

2000

26

52000

... More
code212 - b) 3/0.036 (3/20) mm (2.5 Sqmm Copper wire)

4000

42

168000

... More
code213 - c) 7/0.036 (7/20) (4 Sqmm copper wire)

3000

63

189000

... More
code214 - d)7/0.048 (7/18) mm (6 Sqmm Copper wire)

300

92

27600

... More
code215 - Open Conduit System Supplying heavy gauge PVC conduit pipe …….dia confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using NF screws (a)19/20 mm dia 2 mm thick.

250

69

17250

... More
code216 - b)25 mm dia 2mm thick.

75

81

6075

... More
code217 - c) 32 mm dia 2.5 mm thick.

75

106

7950

... More
code218 - Concealed Conduit System Supplying heavy PVC condiuit pipe ……mm dia ......mm thick confirming to IS 2509 woth suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/1.2) (a) 19 / 20 mm dia 2 mm thick

50

66

3300

... More
code219 - b)25 mm dia 2 mm thick

1500

78

117000

... More
code220 - c)32 mm dia 2.5 mm thick

150

103

15450

... More
code221 - Groove Cutting Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, up to wall surface complete ( 3/1.7) (a)up to 50mm conduit in brick wall

150

29

4350

... More
code222 - Supplying and fixing PVC/Metal conduit accessories.(3/5) (a) 19/20mm deep junction box

10

49

490

... More
code223 - Supplying and fixing PVC/Metal conduit accessories.(3/5) (b) 25mm deep junction box

10

56

560

... More
code224 - Supplying and fixing PVC/Metal conduit accessories.(3/5) (b) 32mm deep junction box

10

61

610

... More
code225 - Supplyind and Fixing Metal Fan Box with Round Hook.(11/32)

160

117

18720

... More
code226 - Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using copper PVC insulated multi strand 2x1.5Sqmm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. (a) Short point up to 3Mtr from tapping point to out let via switch box

20

269

5380

... More
code227 - b) Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch box

120

379

45480

... More
code228 - c) Long point above 6Mtr up to 10Mtr from tapping point to out let via switch box

200

555

111000

... More
code229 - d) Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches

103

677

69731

... More
code230 - e) Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches box

25

989

24725

... More
code231 - Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293. (16/3.7) (a) 6 Amp one way

150

102

15300

... More
code232 - b) 6 Amp two way

6

166

996

... More
code233 - c) 6 Amps 3 way socket.

300

171

51300

... More
code234 - d) Stepped fan regulators

160

276

44160

... More
code235 - e) 6 Amp bell push

10

177

1770

... More
code236 - f) 6/16 A universal switch & socket

10

2136

21360

... More
code237 - g) TV Socket

5

156

780

... More
code238 - g) Telephone Socket

50

156

7800

... More
code239 - h) RJ45 / I.O.outlet

75

337

25275

... More
code240 - i) 16 Amp one way

150

180

27000

... More
code241 - Supplying and flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (7/16) (a) 1-2 Way

25

138

3450

... More
code242 - b) 4-5 Way

50

177

8850

... More
code243 - c) 6 Way

50

220

11000

... More
code244 - d) 8 Way

15

261

3915

... More
code245 - e) 10-12 Way

5

319

1595

... More
code246 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.(7/17) (a) 1 to 2 Module

25

137

3425

... More
code247 - b) 3 Moudule

50

161

8050

... More
code248 - c) 6 Moudule

50

234

11700

... More
code249 - d) 8 Moudule

12

284

3408

... More
code250 - e) 10-12 Moudule

15

344

5160

... More
code251 - f) 16 Moudule

15

397

5955

... More
code252 - Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB ). The entire plug and socket shall b mounted in a themoplastic/powder coated metal box & wired Completely. (57/6.44) 20 Amps SP & N

2

971

1942

... More
code253 - Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB ). The entire plug and socket shall b mounted in a themoplastic/powder coated metal box & wired Completely. (57/6.44) 30 Amps TP & N

2

1700

3400

... More
code254 - A. L.T.SWITCHGEAR AND DISTRUBUTION BOARDS - L.T.PANEL, SMSB-1, 2, EX LTG PANEL AND DISTRIBUTION BOARDS. - Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. (P-41&42/38-b) 16SWG

20400

-

8772

... More
code255 - Supplying of on load change over over switches 4 poles, AC 23Amps duty 415V, 50HZ, AC Supply. 400Amps 4P COS

1

29105

29105

... More
code256 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Microprocessed release and Earth Fault as per IS-13947. ( Icu = Ics) Group-A THREE POLE 320-400Amps 35kA.4P, 35kA

1

30111

30111

... More
code257 - 125-Amps 25kA.TP

3

8598

25794

... More
code258 - 160Amps 25kA.TP

3

11050

33150

... More
code259 - 100Amps 25kA TP

3

6086

18258

... More
code260 - Supplying and fixing of Shunt trip suitable for MCCB.CBCT.(P-36/10)

3

1703

5109

... More
code261 - Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50Hz AC with latest micro controller based,digital readout of percentage leakage current, programmable delay/ auto/manual reset facility suitable tomounton DIN rail/ flush mounting on panel board.

3

9255

27765

... More
code262 - Supplying, fixing and wiring 3 Phase Digital Ammeter /Voltmeter.(P-48/6.27)

3

1425

4275

... More
code263 - Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy. Group 'A' (P-40/29)

1

9315

9315

... More
code264 - Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer.class 0.5 accurecy with Tape Wound.(P-40/30)

9

562

5058

... More
code265 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C.Group 'A' (P-40/34)

7

515

3605

... More
code266 - Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which aremounted on powder coated 40x6mmM.S.flat framework inexistingpanel board.Thebusbar shall havesuitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 400Amps 4x50x10mm Alluminium Strips

2

4445

8890

... More
code267 - 100Amps 4x30x6mm Alluminium Strips

3

2465

7395

... More
code268 - 250Amps 4x30x10mm Alluminium Strips

2

3435

6870

... More
code269 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75x75x6mm

6

555

3330

... More
code270 - 75x150x75X6mm

3

926

2778

... More
code271 - ACCP PANEL (50 KVAR) - Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. 16SWG

7500

-

3225

... More
code272 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Microprocessed release and Earth Fault as per IS-13947. ( Icu = Ics) Group-A (P-34&35/9) THREE POLE 125Amps 25kA.TP

1

8598

8598

... More
code273 - Supplying and fixing of Shunt trip suitable for MCCB.CBCT.(P-36/10)

1

1703

1703

... More
code274 - Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. Group 'A' (P47/15)

1

9255

9255

... More
code275 - Supplying, fixing and wiring 3 Phase Digital Ammeter /Voltmeter.(P-48/6.27)

1

1425

1425

... More
code276 - Supplying, fixingandwiring50/5 to400/5A5VAburdenCurrent Transformer Class 0.5 accuracy with Tape Wound.

3

562

1686

... More
code277 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C.Group 'A' (P-40/34)

3

515

1545

... More
code278 - Fixing a shunt capacitor of … KVAR capacity with necessary clamps, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor a) up to 5 KVAR

2

154

308

... More
code279 - b) 6 to 10 KVAR

2

214

428

... More
code280 - b) 11 to 20 KVAR

2

344

688

... More
code281 - Supplying, fixing and wiring Automatic Power Factor controller fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three place LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect / disconnect banks, with automatic recognition or with standard programs.(56/6.36)

1

21640

21640

... More
code282 - Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic alluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary botls,nuts and washers etc., complete. 250Amps 4x30x10mm Alluminium Strips

2

3435

6870

... More
code283 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75x75x6mm

1.5

555

832.5

... More
code284 - MCB Distribution Board Supplying and fixing regular MCB Distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG M.S enclosure. I - Double Door a) 4Way SP &N

3

1524

4572

... More
code285 - b) 12Way SP &N

1

2329

2329

... More
code286 - a) 4Way TP &N

1

4038

4038

... More
code287 - b) 6Way TP &N

5

4940

24700

... More
code288 - Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board.(Residual current circuit board))(RCCB) a) 16-25 Amps 2 pole (2 Module type)

2

4277

8554

... More
code289 - b) 32-40 Amps 2 pole (2 Module type)

2

4559

9118

... More
code290 - c) 25-40 Amps 4 pole

2

5147

10294

... More
code291 - Supplying and fixing of MINIATURE CIRCUIT BREAKERS in existing distribution boards using necessary fixng materials and "C" type Curve, Indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 SP 6-32Amps

50

415

20750

... More
code292 - DP 6-32Amps

4

739

2956

... More
code293 - TPN 6-32Amps

1

1717

1717

... More
code294 - TPN 40-63Amps

10

3088

30880

... More
code295 - LT CABLES Supplying of 1.1 KV LT UG cable having aluminium conductor PVC insulated, extruded inner sheathed, galvanised, steel strip (except 2Cx 10Sq.mm wire armoured ) Confirming to IS-3975:1990 ( No. of Strip indicated in GTP) & extruded PVC outer sheated armoured cable with specified IS-1554 Part-1:1998 & confirming to the attached GTP of GROUP-A. (62/7.4) 3 1/2 C - 240 Sq.mm A2XFY

100

445

44500

... More
code296 - 3 1/2 C - 50 Sq.mm A2XFY

50

265

13250

... More
code297 - 3 1/2 C - 35 Sq.mm A2XFY

35

204

7140

... More
code298 - 3 1/2 C - 25 Sq.mm A2XFY

40

165

6624

... More
code299 - 4 C - 16 Sq.mm A2XFY

25

140

3510

... More
code300 - 4 C - 10 Sq.mm A2XFY

25

118

2970

... More
code301 - END TERMINATION Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (69/7.14) Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. (70/7.21) 3 1/2 C - 240 Sq.mm A2XFY

4

2180

8720

... More
code302 - 3 1/2 C - 50 Sq.mm

2

336

672

... More
code303 - 3 1/2 C - 35 Sq.mm

14

229

3206

... More
code304 - 4 C - 16 Sq.mm

12

131

1572

... More
code305 - 4 C - 10 Sq.mm

10

117

1170

... More
code306 - LAYING CHARGES FOR CABLES Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required. In existing trench/duct. (68/7.8) 6 sqmm to 16 sqmm

60

10

648

... More
code307 - 25 sqmm to 75 sqmm

85

16

1377

... More
code308 - 95sqmm 150Sqmm

100

42

4240

... More
code309 - PERFORATED TYPE CABLE TRAY Suplying and fixing 2mm thick perforated cable tray with powder coated paint on existing MS angle support using necessary GI bolts/nuts and washer or welding as required.( 63 / 7.19) 150 mm x 50mm

10

440

4400

... More
code310 - SUPPLY OF LIGHT FIXTURES. Supplying CFL mirror light fitting with 2x11W CFL lamp, choke, Perspex cover and completely wired for use on 230V 50Hz AC (25/4.25)

5

648

3240

... More
code311 - Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.1X4'-w 20/22 w

25

690

17250

... More
code312 - Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. 1X4'36/40 w

200

1269

253800

... More
code313 - Supplying of recessed/surface mount aesthetic Square / rectangular modular luminary made out of single piece powder coated CRCA sheet steel accommodating all electrical accessories like elecronic ballast suitable to operate on 230V 50Hz AC supply with 18Watts PLL-compact fluorescent lamp, pre-wired up to terminal block with bright anodized aluminum reflector & P5 paralite louvers with spring loaded plastic toggles. (25/4.20) 1x18Watts

4

1724

6896

... More
code314 - Supplying of recessed/surface mount aesthetic Square / rectangular modular luminary made out of single piece powder coated CRCA sheet steel accommodating all electrical accessories like elecronic ballast suitable to operate on 230V 50Hz AC supply with 18Watts PLL-compact fluorescent lamp, pre-wired up to terminal block with bright anodized aluminum reflector & P5 paralite louvers with spring loaded plastic toggles. (25/4.20) 2x18Watts

4

1939

7756

... More
code315 - SupplyingandfixingofLEDBulkheadof10WwithIP65protection and IK08 impact resistance suitable for surfaceandwallmounting applications.

5

842

4210

... More
code316 - Supply of LED Streetlight luminaire with pressure diecast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising ofanti glare clear diffuser with Injectio nmoulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @Lumen Maintenance of 70%, maximum lightintensity should be between 60 degrees to 70 degrees. CCTGreater than5500K, IP66 optical and electrical compartment &impact resistanceof complete luminaire Greater than IK08. Power Factor Greater than0.9 withmains, Surge Protection-Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of40mm to 50mm.Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60 Hz application. Compliance to IS 10322/IEC 60598,LM79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........WSystem Power consumption. LED EfficiencyGreater than1301m/w, nominal CRI Greater than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO9001:2008. Housingwith supplier wordmark/name shall be Engraved /Embossing on thediecast housing/ Bodypart.Warrantyof2Years again stany manufacturing defect working understand ard electrica lconditions as mentioned above should be given by LED manufacturer &Cree/Nichia/ Lumileds/Osram make LED Source. LED street light 40W

2

4024

8048

... More
code317 - Fabricating, supplying and errecting swaged tubular pole of height …Mtr having three sections, and providing two coats of redoxide paint and finished with two coats of enamelled paint of approved quality and colour and M.S. base plate of suitable size welded at the bottom of the pole(ass per IS) and 40mm dia GI / flexible PVC pipe of 1 mtr length fitted to the heavy guage polycorbonate control box including 5way connector of size 167x125x82mm for 7.5M pole/200x160x98mm for remaining length of pole with front opening cover, with locking arrangements and suitable capacity MCB / DP switch, The pole shall be errected in cement concrete work (1:2:4) including excavation and refilling of planting depth of the pole to the ground level and the coping CC shall be up to 0.6M above ground level as per IS 2713 - 7. (40/5.13) a) Erection of heavy duty pole on Footpath/ median b) 9Mt (5Mt Hb,165.1mm dia 4.85mm thick x2M Hm, 139.7mm dia 4.50mm thick x 2M Ht,114.3mm dia 3.65mm thick) as per IS 410 SP 32.

3

15500

46500

... More
code318 - Supplying and fixing of solar lux level street light control switch single phase including suitable capacity contactor. 3kv

3

10097

30291

... More
code319 - Supplying of Ceiling Fan with Capacitor ratingAsper guidelineof BEE5star ratingandIS:374/19andalsocomplywithIS:1709/1984 withlatestamend ment,Ratedvoltage220V/50Hz,Ratedpowerupto 35W+/-10%,RatedcurrentAsper IS:374/19,Ratedpower factor 0.9lagging(min),Ratedspeed350+/-10%RPM,Ratedairdelivery 210+/-10%CubicMeterMinimum,Ratedservicevalue6.2CMM/ W,ThreeBladesofbladeleaf1.05mmthickAluminiumAlloysheet, Class Bmotor insulation, Bearing Two ball bearings, Top 6202, Bottom6201,asperISspecification,Motorwinding.TempriseShall notexceed75degCoverandambientof400Cbyresistancemethod at245V,InsulationresistanceShallnotbelessthanTwoMegaOhms (2MOhms), Leakage current Should not exceed 210MicroAmp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019with latest amendment, 2year manufacturerWarranty. (BLDC fans) 6.4.1 48" Sweep 5 Star (1200 mm)

185

2677

495245

... More
code320 - SUPPLY OF EXHAUST FAN Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50HZ, AC Supply complete.(84/9.2) (a) 12" sweep (300mm)

17

2969

50473

... More
code321 - FIXING OF EXHAUST FAN Fixing on e exhaust fan in the nitch already left in the wall with bolts and nuts and 5 amps. Ceiling rose wisth sufficient length of 23/0.0076 inch PVC insulated twincore wire. (115/17.12)

17

412

7004

... More
code322 - FIXING OF CEILING FAN Extra length of GI pipe of class B 19mm dia for down rod. (109 / 17.10)

10

164

1640

... More
code323 - SUPPLY OF WALL FAN Supplying wall mounting fan suitable to operate at single-phase 230 V A.C. supply,(84/9.4) 400mm Sweep

1

3212

3212

... More
code324 - NETWORKING AND TELECOMMUNICATION Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable.. Two Pair (Tag block to outlet).

200

21

4200

... More
code325 - Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable.. 5 Pair

10

46

460

... More
code326 - Supply and fixing 20 pair telephone tag block "Krone make".

2

1500

3000

... More
code327 - Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-oxial TV cable. RG-6.

10

40

400

... More
code328 - Supplying and drawing UTP-CAT 6E LAN cable.

2000

38

76000

... More
code329 - Supplying & Fixing of switch mounting rack with power manager & Cable manager . . 18U with 650mm depth

3

28396

85188

... More
code330 - Supplying & Fixing of switch mounting rack with power manager & Cable manager . .(85 / 11.4) Supplying & Fixing of Power strip

3

1457

4371

... More
code331 - Supplying & Fixing of switch mounting rack with power manager & Cable manager . . Supplying of shelf

1

827

827

... More
code332 - Supplying & Fixing of switch mounting rack with power manager & Cable manager . . Supplying & fixing of Castor wheels to the Shelf. (set of 4)

6

1582

9492

... More
code333 - Supplying & Fixing of switch mounting rack with power manager & Cable manager . .

2

1209

2418

... More
code334 - Supplying fixing of Network Switches. 24 port 10/100/1000 Switch

1

7415

7415

... More
code335 - Supplying & fixing of I/O socket eith back box Single I/o

1

490

490

... More
code336 - Supplying & fixing of I/O socket eith back box Double I/o

10

550

5500

... More
code337 - Supplying & Fixing of …mtrs Cat6 Patch Cable 1mtr

50

224

11200

... More
code338 - Supplying & Fixing of Patch panel for Lan cabling 24 Port 10/100 patch panel

1

4100

4100

... More
code339 - UPS & ACCESSORIES Supplying, erection, testing and commissioning of Off-Line UPS system suitable for operation on 230 V, 50Hz, A/C supply, with all accessories complete and Excluding batteries and wiring complete. a) 5KVA Off Line UPS Two Hour back up Excluding 6 x 150Ah batteries

1

39898

39898

... More
code340 - AH Batteries Supplying, installation, testing & commissioning of 12 Volts DC, AH Batteries in poly propylene container for U.P.S. Low maintenance Tubular batteries a) 6 x 12 V, 150 AH capacity Acid Battery

2

28187

56374

... More
code341 - EXTERNAL ELECTRIFICATION - Providing 2 pole structure at the tapping point. (2 nos) - Material cost - RCC D.P structure using 9 mtrs RCC Pole with WL 145 kg

2

17402

34804

... More
code342 - 45 kN Disc Insulators

12

510

6120

... More
code343 - Guy Set Complete

4

742

2968

... More
code344 - Spiral Earth Electrodes

4

239

956

... More
code345 - Concrete for Guy set (without cement)

4

158

632

... More
code346 - Caution / Danger Board

2

150

300

... More
code347 - Anti - Climbing Device (12mtrs / 1 kg G.I. Barbed Wire) Lumpsum

4

89

356

... More
code348 - 11 kV 400 A D/B GOS

2

18634

37268

... More
code349 - H-Frame for mounting GOS

2

4332

8664

... More
code350 - Concreting of 9Mts RCC Poles - Base Concreting in CC 1:4:8 500x650x150mm

4

229

916

... More
code351 - Pole Concreting in CC 1:2:4 650x500x1700mm

4

2566

10264

... More
code352 - Coping in CC 1:2:4 and as per actuals

4

444

1776

... More
code353 - Earthing of DP set with GI Pipe

4

1277

5108

... More
code354 - Lighting arestors metal oxide 9 Kv, 5Kv

2

2070

4140

... More
code355 - Painting of 9Mts RCC Poles

4

960

3840

... More
code356 - Labour cost - RCC D.P structure using 9 mtrs RCC Pole with WL 145 kg

2

4134

8268

... More
code357 - Guy Set Complete

4

327

1308

... More
code358 - Spiral Earth Electrodes

4

93

372

... More
code359 - Caution / Danger Board

2

80

160

... More
code360 - Anti - Climbing Device (12mtrs / 1 kg G.I. Barbed Wire) Lumpsum

4

42

168

... More
code361 - 11 kV 400 A D/B GOS

2

1214

2428

... More
code362 - H-Frame for mounting GOS

2

323

646

... More
code363 - Earthing of DP set with GI Pipe

4

507

2028

... More
code364 - Lighting arestors metal oxide 9 Kv, 5Kv

2

63

126

... More
code365 - Extension of 11 KV line from the existing sub station / Feeder (1 KM) - Material cost - 9.0M Long, RCC Pole 145 kg WL (for Deadend, Anchor points.

4

7076

28304

... More
code366 - 11kv Horizontal cross arms with HT st supports bolt, nut and washers

4

487

1948

... More
code367 - 45 Kn Disc Insulators

1

510

510

... More
code368 - 11 KV Pin Insulators with GI Pins

12

87

1044

... More
code369 - Rabbit ACSR Conductor

0.1

46234

4623.4

... More
code370 - PG Clamp for rabbit to rabbit conductor

2

102

204

... More
code371 - Guy sets

2

742

1484

... More
code372 - Concreting Materials for guy sets

2

158

316

... More
code373 - Spiral earth electrode

6

239

1434

... More
code374 - Concereting of 9Mts RCC Poles - Base Concreting in CC 1:4:8 500x650x150mm

4

229

916

... More
code375 - Pole Concerecting in CC 1:2:4 500x650x1700mm

4

2566

10264

... More
code376 - Coping in CC 1:2:4 and asper actuals

4

444

1776

... More
code377 - Caution / Danger Board

2

150

300

... More
code378 - Anti - Climbing Device (10mtrs / 1 kg G.I. Barbed Wire) Lumpsum

5

89

445

... More
code379 - Transportation of robit ACSCR Conductor and all other materials at 2% on material cost

1

25000

25000

... More
code380 - Labour Cost - 9.0M Long, RCC Pole 145 kg WL (for Deadend, Anchor points.

4

4134

16536

... More
code381 - 11kv Horizontal cross arms with HT st supports bolt, nut and washers

4

99

396

... More
code382 - Rabbit ACSR Conductor

0.1

2608

260.8

... More
code383 - Guy sets

2

354

708

... More
code384 - Spiral earth electrode

6

93

558

... More
code385 - Caution / Danger Board

2

80

160

... More
code386 - Anti - Climbing Device (10mtrs / 1 kg G.I. Barbed Wire) Lumpsum

5

42

210

... More
code387 - Loading & unloading of poles

1

8000

8000

... More
code388 - Erection of HT Metering Cubical - Material cost - 11KV HT Metering Panel 3CTS, 3PTS for 3poles 4 wires metering with transparent cover TTB with 3x8 mm Copper busbar (HT metering box fabricated out of 3mm MS sheet dule epoxy powder coated with out meter)

1

140585

140585

... More
code389 - Load break switch for HT metering cubicle

1

124500

124500

... More
code390 - 0.2 S' class ETV meter with ABT teature and DLMS protocall with TOD foar above

1

20000

20000

... More
code391 - Earthing HT Metering cubicle with GI pipe

2

1277

2554

... More
code392 - Construction of plot form exevation of 1.5x1.5x 1 mtr pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 1cm thick layers well compacted curing etc., complete providing and construction of stone masonry 0.9 mt below ground level and 1.2mtr above ground level neatly dressed in CC 1:6 cutting completes providing painting to stone masonry in cm 1:3 after reacting joint and nicely joint and nicely laying curing etc., plastering they consider sand face in cm 1:4 including smooth rendering curing etc., caring at every no stops completely

1

25192

25192

... More
code393 - Labour cost - 11KV HT Metering Panel 3CTS, 3PTS for 3poles 4 wires metering with transparent cover TTB with 3x8 mm Copper busbar (HT metering box fabricated out of 3mm MS sheet dule epoxy powder coated with out meter)

1

1208

1208

... More
code394 - Load break switch for HT metering cubicle

1

706

706

... More
code395 - 0.2 S' class ETV meter with ABT teature and DLMS protocall with TOD foar above

1

1145

1145

... More
code396 - Earthing HT Metering cubicle with GI pipe

2

573

1146

... More
code397 - ERECTION OF COMPACT PRE-FABRICATED PACKAGED SUB-STATION 3 PHASE11 kV/433 V 250KVA DISTRIBUTION TRANSFORMER - Material cost - Packaged sub-station 11kv/433V consisting of 3 way SF6/VCB insulated compact RMU oil cooled type copper wound transformer and LT section with one MCCB incoming and 7 nos outgoing. 250 Kva oil cooled transformer

1

1491923

1491923

... More
code398 - Earthing materials pipe type for grounding as per Drawing No. BESCOM/GM/CP/15 & 34/Dt: 24.10.07.

4

1277

5108

... More
code399 - Caution / Danger Board as per Drawing No. BESCOM/GM/CP/40/Dt: 24.10.07

2

120

240

... More
code400 - Anti - Climbing Device (12mtrs / 1 kg G.I. Barbed Wire) Lumpsum

5

64

320

... More
code401 - Construction of platform (3x3x1.2) mtr in size stone, for erection of transformers/Heavy equipment including all materials, labour. Excavation of (4x4x1.5) mt pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 1cm thick layers, well compacted curing etc., complete providing and construction of stone masonry 0.9m below ground level and 1.2m above ground level neatly hammer dressed in cement morter 1:6 cutting complete providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completely.

1

25192

25192

... More
code402 - Labour cost - Packaged sub-station 11kv/433V consisting of 3 way SF6/VCB insulated compact RMU oil cooled type copper wound transformer and LT section with one MCCB incoming and 7 nos outgoing. 250 Kva oil cooled transformer

1

8467

8467

... More
code403 - Earthing materials pipe type for grounding as per Drawing No. BESCOM/GM/CP/15 & 34/Dt: 24.10.07.

4

573

2292

... More
code404 - Caution / Danger Board as per Drawing No. BESCOM/GM/CP/40/Dt: 24.10.07

2

43

86

... More
code405 - Anti - Climbing Device (12mtrs / 1 kg G.I. Barbed Wire) Lumpsum

5

25

125

... More
code406 - HT CABLE 11 KV 3 core 95 sq.mm XLPE UG Cable - Material Cost 11 kV Class 3X 95 Sq.mm XLPE UG Cable

25

548

13721.5

... More
code407 - Cable termination kit Out door HS Type Suitable for 95 Sq.mm - Per Kit

1

2990

2990

... More
code408 - Cable termination kit In door HS Type Suitable for 95 Sq.mm --Per Kit

3

2753

8259

... More
code409 - Cable covering tiles 250X125X40 mm or 125x125x40 mm

100

10

1000

... More
code410 - Sand

5

1700

8500

... More
code411 - RCC Hume pipe, 2000 mm long, 150 mm dia

6

300

1800

... More
code412 - Collars for RCC Hume pipe

4

80

320

... More
code413 - GI Pipe, 150 mm dia for drain crossing, cable raising etc.,

6

1144

6864

... More
code414 - Route and joint indicating stones

5

120

600

... More
code415 - Labour charges - Cable trench excavation, 1025x0.6x1=600, Ordinary soil

12

205

2460

... More
code416 - b) Laying of cable in trench

25

35

895

... More
code417 - c) Refilling and consolidation

12

45

540

... More
code418 - d) Making of cable terminations

4

1554

6216

... More
code419 - f) Covering the cable with tiles

12

2

31.2

... More
code420 - g) Spreading Sand and forming with Sand round the cable

25

9

228.75

... More
code421 - h) Laying of RCC Hume pipes

12

40

480

... More
code422 - i) Laying of GI Pipe

2

45

90

... More
code423 - j) Laying of Route and Joint indicating stones

5

68

340

... More
code424 - Regular Labour Charges

1

41522

41522

... More
code425 - Chain link fencing - Providing chain link fencing 50mm size o f 8 guage properly stretched between rectangular poles and fixed with suitable bolts & nuts, the free ends shall be welded to the pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction o f the engineer incharge for work including two coats of approved quality paint over one coat o f primer paint.

92.4

300

27720



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.