Karnataka Housing Board Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Karnataka Housing Board - KHB Tender

Works
Civil And Construction
Building Construction
Opening Date17 Jan 2025
Closing Date17 Feb 2025
Tender Amount₹ 6,52,91,682.98 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (Vol -I- Pg No.7-Item No:1.9) Qty of earthwork required to fill in foundation sides

1796.9358

279

501884.16894

... More
code05 - Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Remaining earthwork available, (Vol -I- Pg No.7-Item No:1.1)

268.96

454

122282.664

... More
code06 - Construction of Embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded with desired compaction. (Royalty shall be recovered @ Rs. 60.00/m3) (vol -1- Page No. 7, Item No:1.7)

850

124

106207.5

... More
code07 - Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. If the height of embankment construction is more than 1.50 m add 5% per m3 for every 1.50 m height or part there of (vol -1- Page No. 7, Item No:1.8)

952.44

497

474029.388

... More
code08 - Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.. (vol -II- Page No. 5, Item No:4.1)

1150

123

142485

... More
code09 - Anchoring of T20 Drill rods with drilling of hole for the depth of 600mm and filled with chemical lock set (Hilly/Fosroc )as per the instructions whereever necessary in hard rock are with cost of all materials of quality, labour,and machinery, complete the work as per technical specifications.

324

800

259200

... More
code10 - PCC : Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates. (vol -I- Page No. 15, Item No:2.1.2), Footing and curtain Wall

84.01

5947

499624.272

... More
code11 - PCC : Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates. (vol -I- Page No. 15, Item No:2.1.2), Inside Area

115

5947

683928

... More
code12 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates- (Vol -I- Page No. 15, Item No:2.1.6),DPC

0.34

6555

2228.751

... More
code13 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates. (Vol -I- Page No. 15, Item No:2.1.4) Ground Floor

6.7

6527

43736.595

... More
code14 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates. (Vol -I- Page No. 15, Item No:2.1.4) First Floor

8.52

6593

56173.4676

... More
code15 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates. (Vol -I- Page No. 15, Item No:2.1.4) Third Floor

8.05

11430

92013.6735

... More
code16 - RCC : Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ( Vol -1 - Page No : 15- Item No.2.2.3) Footing

145.88

7185

1048150.7176

... More
code17 - RCC : Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ( Vol -1 - Page No : 15- Item No.2.2.3) Padestal

18.91

7185

135868.7282

... More
code18 - Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/ trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.(Vol -1 - Page : 16, It No.2.4.3) Curtain Wall

89.95

7318

658261.296

... More
code19 - Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/ trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.(Vol -1 - Page : 16, It No.2.4.3) PLINTH BEAM-(200x450)

52.09

9979

519816.528

... More
code20 - Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/ trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.(Vol -1 - Page : 16, It No.2.4.3) Staircase Concrete

16.69

9979

166552.848

... More
code21 - Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/ trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.(Vol -1 - Page : 16, It No.2.4.3) a.Column from pedestal top to Plinth Lvl

20.41

11309

230832.2016

... More
code22 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Vol -1 - Page : 16, It No.2.5.2) Ground Floor

49.54

12214

605119.2104

... More
code23 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Vol -1 - Page : 16, It No.2.5.2) First Floor

31.72

12336

391326.468

... More
code24 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Vol -1 - Page : 16, It No.2.5.2) Terrace Floor

5.35

12459

66655.9175

... More
code25 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Vol -1 - Page : 16, It No.2.5.2) Ground Floor Beam

65.69

11496

755188.0056

... More
code26 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Vol -1 - Page : 16, It No.2.5.2) First Floor Beam

39.61

11611

459919.632

... More
code27 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Vol -1 - Page : 16, It No.2.5.2) Terrace Floor Beam

5.77

11726

67659.9432

... More
code28 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Vol -1 - Page : 16, It No.2.5.2) Ground Floor Slab

164.66

10777

1774661.0218

... More
code29 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Vol -1 - Page : 16, It No.2.5.2) First Floor Slab

85.2

10885

927444.6

... More
code30 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Vol -1 - Page : 16, It No.2.5.2) Terrace Floor Slab

1.89

10993

20777.2992

... More
code31 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Vol -1 - Page : 16, It No.2.5.2) Lintel Ground Floor

13.97

11496

160602.4728

... More
code32 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Vol -1 - Page : 16, It No.2.5.2) Lintel First Floor

10.4

11611

120756.48

... More
code33 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Vol -1 - Page : 16, It No.2.5.2) Lintel Terrace Floor

2.46

11726

28846.3536

... More
code34 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Vol -1 - Page : 16, It No.2.5.2) Stair Case Ground Floor

10.44

10777

112519.5012

... More
code35 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Vol -1 - Page : 16, It No.2.5.2) Stair Case First Floor

10.44

10885

113644.62

... More
code36 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Vol -1 - Page No.16, It No.2.5.2) Ground floor-Chajja

9.55

10317

98535.2765

... More
code37 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Vol -1 - Page No.16, It No.2.5.2) First floor-Chajja

7.66

10421

79824.86

... More
code38 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Vol -1 - Page No.16, It No.2.5.2) Terrace floor-Chajja

0.35

11376

3981.6945

... More
code39 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (Vol -I- Page No.18, Item No.2.11(a)) Ground floor

66.99

89457

5992724.43

... More
code40 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (Vol -I- Page No.18, Item No.2.11(a)) First floor

26.31

94869

2496007.3365

... More
code41 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (Vol -I- Page No.18, Item No.2.11(a)) Terrace floor

4.85

95808

464670.9825

... More
code42 - Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (Flag Pole) (Vol -II- Page No.9, Item No.5.4)

8.17

6708

54808.0365

... More
code43 - Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks as per IS 2185 (Part III) in super structure above plinth level up to floor I level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (Vol -II- Page No.17, Item No.6.31) Ground Floor

239.9

8386

2011885.365

... More
code44 - Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks as per IS 2185 (Part III) in super structure above plinth level up to floor I level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (Vol -II- Page No.17, Item No.6.31) First Floor

168.42

8470

1426552.7682

... More
code45 - Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks as per IS 2185 (Part III) in super structure above plinth level up to floor I level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (Vol -II- Page No.17, Item No.6.31) Terrace Floor

42.3

8554

361837.584

... More
code46 - Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks as per IS 2185 (Part III) in super structure above plinth level up to floor I level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (Vol -II- Page No.17, Item No.6.31) Ground Floor

23.17

8386

194311.7295

... More
code47 - Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks as per IS 2185 (Part III) in super structure above plinth level up to floor I level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (Vol -II- Page No.17, Item No.6.31) First Floor

26.29

8386

220477.1415

... More
code48 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Vol -II- Page No.17, It No 6.33) Ground Floor

101.38

1292

131038.719

... More
code49 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Vol -II- Page No.17, It No 6.33) First Floor

151.72

1305

198067.4256

... More
code50 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Vol -II- Page No.17, It No 6.33) Terrace Floor

162.5

1318

214240

... More
code51 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Vol -II- Page No.17, It No.6.34) Ground floor

90.13

1159

104478.696

... More
code52 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Vol -II- Page No.17, It No.6.34) First floor

54.07

1170

63304.6153

... More
code53 - Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerin- charge..(Inside walls) (Vol -II- Page No.42, It No.8.6.1) Ground floor

2925.97

339

992342.7255

... More
code54 - Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerin- charge..(Inside walls) (Vol -II- Page No.42, It No.8.6.1) First floor

1947.98

342

667261.0692

... More
code55 - Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerin- charge..(Inside walls) (Vol -II- Page No.42, It No.8.6.1) Terrace floor

113.75

345

39349.5375

... More
code56 - Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge...External (Vol -II- , Page.42, Item No.8.7) Ground Floor

892.46

384

342972.378

... More
code57 - Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge...External (Vol -II- , Page.42, Item No.8.7) First Floor

901

388

349714.14

... More
code58 - Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge...External (Vol -II- , Page.42, Item No.8.7) Terrace Floor

576.1

391

225825.439

... More
code59 - Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge...(Inside rough Plastering) (Vol -II- , Page.42, Item No.8.7) Ground Floor

292.19

384

112288.617

... More
code60 - Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge...External (Vol -II- , Page.42, Item No.8.7) First Floor

166.9

388

64780.566

... More
code61 - Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment. Plaster mesh 100mm wide, (Vol -II- Page No. 43, It No.8.16.3) Ground Floor

879.2

46

40619.04

... More
code62 - Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment. Plaster mesh 100mm wide, (Vol -II- Page No. 43, It No.8.16.3) First Floor

517.25

46

24134.885

... More
code63 - Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment. Plaster mesh 100mm wide, (Vol -II- Page No. 43, It No.8.16.3) Terrace Floor

194.86

47

9181.8032

... More
code64 - Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.. (Vol -II- Page No.100, It No.12.11) Ground Floor

0.33

144977

47842.641

... More
code65 - Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as perspecifications. ( excluding cost of fixtures ) (Vol -II- Page No.100, It No.12.15)

10.8

7816

84414.96

... More
code66 - Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (Vol -II- Page No.100, It No.12.31.1) Ground Floor

1.05

103755

108943.5375

... More
code67 - Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (Vol -II- Page No.100, It No.12.31.1) First Floor

0.72

104793

75451.1832

... More
code68 - Fixing of door frame in an existing opening including embeeding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debries with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. (Vol -II- Page No.104, It No.12.51)

50

1066

53340

... More
code69 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial (Both Side Laminated Finish) (Vol -II- Page No.105 It No.12.57.6) Ground Floor

38.1

3488

132896.61

... More
code70 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial (Both Side Laminated Finish) (Vol -II- Page No.105 It No.12.57.6) First Floor

28.8

3522

101461.824

... More
code71 - Providing and fixing factory made single extruded WPC (Wood PolymerComposite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (SuspensionGrade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for100 g) fabricated with miter joints after applying PVC solvent cement andscrewed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) &1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus ofelasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fireretardant and fixed in position with M.S hold fast/lugs/SS dash fastenersof required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)Ground Floor , (Vol -II- Page No. 111, It No.12.93.1)

83.8

737

61768.98

... More
code72 - Providing and fixing factory made single extruded WPC (Wood PolymerComposite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (SuspensionGrade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for100 g) fabricated with miter joints after applying PVC solvent cement andscrewed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) &1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus ofelasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fireretardant and fixed in position with M.S hold fast/lugs/SS dash fastenersof required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)First Floor , (Vol -II- Page No. 111, It No.12.93.1)

91.2

744

67895.664

... More
code73 - Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness, (Vol -II- Page No 112, It No. 12.94.1) Ground Floor

25.68

3659

93969.54

... More
code74 - Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness, (Vol -II- Page No 112, It No. 12.94.1) First Floor

28.8

3695

106440.192

... More
code75 - Providing and fixing ISI marked oxidised M.S.Handles confirming to IS: 4992 with necessary screws etc. complete. (Only For Toilet Doors), All floors, vol -II- Page No.107, It No.12.73.1)

54

46

2494.8

... More
code76 - Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete(Only for toilet doors), (Vol -II- Page No.105, It No.12.63)

27

136

3685.5

... More
code77 - Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc.-125x65x2.12mm.(For toilet doors) vol -II- Page no.106, It No12.68.1)

81

57

4677.75

... More
code78 - Providing and fixing MS Hold fasts (For all the doors), (vol -II- A-25, It No.444)

462

52

24255

... More
code79 - Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)(Vol -II- Page No.110, It no.12.9) Ground Floor

97.02

7070

685999.314

... More
code80 - Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)(Vol -II- Page No.110, It no.12.9) First Floor

71.82

7141

512896.0662

... More
code81 - Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)(Vol -II- Page No.110, It no.12.9) Terrace Floor

5.04

7212

36349.0344

... More
code82 - Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE (Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (Vol -II- 109, It No.12.85) Ground Floor

33.93

6004

203747.9535

... More
code83 - Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE (Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (Vol -II- 109, It No.12.85) First Floor

22.59

6065

137008.35

... More
code84 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. (Vol -II-Page No. 86, 11.34 A) Ground Floor

2749.95

176

485091.18

... More
code85 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. (Vol -II-Page No. 86, 11.34 A) First Floor

2383.5

178

424644.36

... More
code86 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. (Vol -II-Page No. 86, 11.34 A) Terrace Floor

897.33

179

161456.5869

... More
code87 - Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.( vol -II- Page No.77, It No.11.5.1) Ground Floor

9.6

4701

45138.24

... More
code88 - Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.( vol -II- Page No.77, It No.11.5.1) TerraceFloor

4.2

4795

20142.948

... More
code89 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Ground Floor, vol -II- Page No.85, It No.11.28)

828.38

593

491436.435

... More
code90 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. First Floor, vol -II- Page No.85, It No.11.28)

329.77

599

197591.5886

... More
code91 - Providing and fixing antiuqe brass fittings like Lock, Aldrop, of size 300x16mm, Tower bolts of size 200X12mm and 300X12mm,Hinges 125mm Handles of size 250 &200 mm Door stoper 150mm, Clamps of approved make and quality including cost and conveance of all materials and as per the direction of EIC of work with all lead and lift and directed by the engineer in charge of works

1

16000

16000

... More
code92 - Providing and fixing Aluminium fixtures like Aldrops of size 300 x 16 mm, Tower bolts of size 200 x 12 mm, Latches of size 250 x12 mm, 100 mm length oxidized Iron Hinges, Handles of size 150 mm, Door Stopper & Door Bush of approved make and quality including cost and conveyance of all materials and as per the direction of EIC of work with all lead and lift and as directed by the Engineer in charge of works. Single Shutter.

22

4663

102586

... More
code93 - Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.(Vol -II- Page No.61, It No.9.17.2) Ground Floor

523.08

1233

645349.95

... More
code94 - Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.(Vol -II- Page No.61, It No.9.17.2) First Floor

293.95

1246

366288.1555

... More
code95 - Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. (Vol -II- Page No.63, It No.9.24) Ground Floor

484.78

2994

1451722.188

... More
code96 - Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. (Vol -II- Page No.63, It No.9.24) First Floor

434.46

3024

1314045.993

... More
code97 - Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. (vol -II- Page No.64, It No.9.3), Ground Floor Stair Case and Entrance Steps

89.21

5594

499076.424

... More
code98 - Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. (vol -II- Page No.64, It No.9.3), First Floor Stair Case

53.25

5650

300880.605

... More
code99 - Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth.(vol -II- Page No.70, It No10.80) Ground Floor

12

2928

35141.4

... More
code100 - Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth.(vol -II- Page No.70, It No10.80) First Floor

12

2957

35492.76

... More
code101 - Providing and laying flooring and steps machine cut granite slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specifications. (vol -II- Page 63, It No.9.28)

33.53

4492

150648.6135

... More
code102 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. (vol -II- Page 60, It No.9.11) Ground Floor

56.43

933

52674.5835

... More
code103 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. (vol -II- Page 60, It No.9.11) First Floor

46.42

942

43763.8476

... More
code104 - Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (Vol -II- Page No. 65, It No.9.39)Ground Floor

292.19

1521

444552.4755

... More
code105 - Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (Vol -II- Page No. 65, It No.9.39) First Floor

166.9

1536

256468.554

... More
code106 - Providing and laying chequerred precast cement concrete concrete tiles 22mm thick in footpath & courtyard ,jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc., complete, on 20mm thick bed of cement mortar 1:4 (Medium shade pigment using 50% white cement 50% grey cement), (Vol -II- Page No.59, It No.9.6.2)

205.51

1251

257216.316

... More
code107 - Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 L per 50 kg of cement or as per direction of Engineer incharge., (Vol -II- Page No.59, It No.9.20)

49.5

840

41580

... More
code108 - Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Vol -II- Page No.48, It No.8.41) Ground Floor

125

175

21918.75

... More
code109 - Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Vol -II- Page No.48, It No.8.41) First Floor

108.34

177

19187.014

... More
code110 - Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Vol -II- Page No.48, It No.8.41) Terrace Floor

42.73

178

7642.6878

... More
code111 - Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge.(Both side) (Vol -II- Page No.50, It No.8.55.1) Ground Floor

103.67

58

6095.796

... More
code112 - Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge.(Both side) (Vol -II- Page No.50, It No.8.55.1) First Floor

61.06

59

3626.3534

... More
code113 - Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. (Vol -II- Page No.54, It No.8.82)

28.08

710

19960.668

... More
code114 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Vol -II- Page No.50, It No.8.51) Ground Floor

3893.13

105

408778.65

... More
code115 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Vol -II- Page No.50, It No.8.51) First Floor

2449.48

106

259767.354

... More
code116 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Vol -II- Page No.50, It No.8.51) Terrace Floor

175.45

108

18974.9175

... More
code117 - Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Vol -II- Page -46, It No.8.33.1) Ceiling and Internal Wall Quantity GF

3893.13

165

645870.267

... More
code118 - Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Vol -II- Page -46, It No.8.33.1) Ceiling and Internal Wall Quantity FF

2449.48

167

410434.8688

... More
code119 - Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Vol -II- Page -46, It No.8.33.1) Ceiling and Internal Wall Quantity TF

175.45

169

29689.649

... More
code120 - Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GF Same As External Plastering Quantity-100%, (Vol -II-Page 46, It No.8.31)

892.46

186

166800.774

... More
code121 - Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FF Same As External Plastering Quantity-100%, (Vol -II-Page 46, It No.8.31)

901

188

170081.77

... More
code122 - Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TF Same As External Plastering Quantity-100%, (Vol -II-Page 46, It No.8.31)

576.1

190

109827.704

... More
code123 - Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Vol II-Page No.26, It No.7.38)

70

596

41771.8

... More
code124 - Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top co. Ridges plain (500 - 600mm) (Vol II-Page .26, It No .7.39.1)

53

473

25112.46

... More
code125 - Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top co. Gutter(600 mm over all girth) (Vol II-Page .26, It No .7.39.6)

53

1128

59802.02

... More
code126 - Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. (Vol -II- Page No.149, It No.15.1) First Floor Terrace Area

643.06

866

557166.4758

... More
code127 - Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. (Vol -II- Page No.149, It No.15.1) Terrace Floor Terrace Area

653.85

875

572125.2885

... More
code128 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates- (Vol -1 - Page No.15, It No.2.1.6) First Floor

19.35

6620

128110.545

... More
code129 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates- (Vol -1 - Page No.15, It No.2.1.6) Terrace Floor

29.25

6686

195572.8125

... More
code130 - Providing 12 mm cement plaster with Cement mortar 1:4 (1cement: 4 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete (vol -II-Page No.41, It No.8.4.2)

1074.85

337

362686.6355

... More
code131 - Cinder Concrete For Sunken Filling: Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. (Vol -II- Page No.23, It No.7.18)

30.86

2117

65356.851

... More
code132 - INTERNAL PLUMBING :Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. (Vol -II- Page No.125, It No.13.50.5) 40mm dia pipes, From wash basin waste lines (GF Toilet)

15

319

4788

... More
code133 - Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. (Vol -II- Page No.125, It No.13.50.6)50mm dia pipes, From sink & urinal waste lines (GF Toilet)

8

405

3242.4

... More
code134 - INTERNAL PLUMBING :Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. (Vol -II- Page No.125, It No.13.50.5) 40mm dia pipes, From wash basin waste lines (FF Toilet)

10

319

3192

... More
code135 - Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. (Vol -II- Page No.125, It No.13.50.6)50mm dia pipes, From sink & urinal waste lines (FF Toilet)

5

405

2026.5

... More
code136 - Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) (Vol -II- Page No.128, It No.13.64.1) 75mm nominal dia pipes (GF Toilet)

50

303

15172.5

... More
code137 - Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) (Vol -II- Page No.128, It No.13.64.1) 75mm nominal dia pipes (FF Toilet)

35

303

10620.75

... More
code138 - Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) (Vol -II- Page No.128, It No.13.64.2) 110mm nominal dia pipes (GF Toilet)

45

404

18191.25

... More
code139 - Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) (Vol -II- Page No.128, It No.13.64.2) 110mm nominal dia pipes (FF Toilet)

40

404

16170

... More
code140 - Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 75 mm diameter. (Vol -II- Page No.125, It No.13.47)

50

206

10342.5

... More
code141 - Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter. (Vol -II- Page No.125, It No.13.48)

50

305

15277.5

... More
code142 - Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete. (Vol -II- Page No.128, It No.13.63) GF Toilet

25

256

6405

... More
code143 - Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete. (Vol -II- Page No.128, It No.13.63) FF Toilet

25

256

6405

... More
code144 - Sanitary and CP fixtures: Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (Vol -II- Page No.128, It No.14.31) GF Toilet

10

1281

12810

... More
code145 - Sanitary and CP fixtures: Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (Vol -II- Page No.128, It No.14.31) FF Toilet

10

1281

12810

... More
code146 - Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 g (Vol -II- Page No.137, It No.14.38) GF Toilet

15

152

2283.75

... More
code147 - Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 g (Vol -II- Page No.137, It No.14.38) FF Toilet

15

152

2283.75

... More
code148 - Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931. (Vol -II- Page No.119, It No.13.16) GF Toilet

10

152

1522.5

... More
code149 - Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931. (Vol -II- Page No.119, It No.13.16) FF Toilet

10

152

1522.5

... More
code150 - Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :: W.C. pan with ISI marked white solid plastic seat and lid. (Vol -II- Page No.131, It No.14.3.1) GF Toilet

8

6275

50206.8

... More
code151 - Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :: W.C. pan with ISI marked white solid plastic seat and lid. (Vol -II- Page No.131, It No.14.3.1) FF Toilet

4

6275

25103.4

... More
code152 - Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. (Vol -II- Page No.131, It No.14.1.1) GF Toilet

5

5128

25641

... More
code153 - Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. (Vol -II- Page No.131, It No.14.1.1) FF Toilet

4

5128

20512.8

... More
code154 - Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: One urinal basin with 5 litre white P.V.C. automatic flushing cistern.. (Vol -II- Page No.131, It No.14.4.1) GF Toilet

5

4676

23383.5

... More
code155 - Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: One urinal basin with 5 litre white P.V.C. automatic flushing cistern.. (Vol -II- Page No.131, It No.14.4.1) FF Toilet

5

4676

23383.5

... More
code156 - Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps. (Vol -II- Page No.132, It No.14.7.1) GF Toilet

10

3236

32361

... More
code157 - Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps. (Vol -II- Page No.132, It No.14.7.1) FF Toilet

8

3236

25888.8

... More
code158 - Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. (Vol -II- Page No.119, It No.13.15) GF Toilet

40

761

30450

... More
code159 - Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. (Vol -II- Page No.119, It No.13.15) FF Toilet

36

761

27405

... More
code160 - Providing and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. (Vol -II- Page No.135, It No.14.22A) GF Toilet

20

850

17010

... More
code161 - Providing and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. (Vol -II- Page No.135, It No.14.22A) FF Toilet

20

850

17010

... More
code162 - Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore) GF Toilet,(Vol-2 Pg No.18 It No.13.8.1.1)

20

87

1743

... More
code163 - Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore) FF Toilet,(Vol-2 Pg No.18 It No.13.8.1.1)

20

87

1743

... More
code164 - Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g (Vol-2 Pg No.137 It No.14.37.1) GF Toilet

20

321

6426

... More
code165 - Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g (Vol-2 Pg No.137 It No.14.37.1) FF Toilet

20

321

6426

... More
code166 - Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g (Vol-2 Pg No.137 It No.14.36.1) GF Toilet

20

94

1890

... More
code167 - Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g (Vol-2 Pg No.137 It No.14.36.1) FF Toilet

20

94

1890

... More
code168 - Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g (Vol-2 Pg No.121, It No.13.28)

80

67

5376

... More
code169 - Providing and fixing brass bib cock of approved quality 15 mm nominal bore (Vol-2 Pg No.115, It No.13.2.1)

25

300

7507.5

... More
code170 - Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. (Vol-2 Pg No.63, It No.9.29)

12

4521

54255.6

... More
code171 - WATER SUPPLY: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes, (Vol-2 Pg No.122, It No.13.32.1) Ground Floor

70

324

22711.5

... More
code172 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes, (Vol-2 Pg No.122, It No.13.32.2) Ground Floor

55

397

21887.25

... More
code173 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25mm nominal dia Pipes, (Vol-2 Pg No.122, It No.13.32.3) Ground Floor

35

500

17529.75

... More
code174 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32mm nominal dia Pipes, (Vol-2 Pg No.122, It No.13.32.4) Ground Floor

25

584

14621.25

... More
code175 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes, (Vol-2 Pg No.122, It No.13.32.1) First Floor

50

324

16222.5

... More
code176 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes, (Vol-2 Pg No.122, It No.13.32.2) First Floor

50

397

19897.5

... More
code177 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25mm nominal dia Pipes, (Vol-2 Pg No.122, It No.13.32.3) First Floor

30

500

15025.5

... More
code178 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32mm nominal dia Pipes, (Vol-2 Pg No.122, It No.13.32.4) First Floor

25

584

14621.25

... More
code179 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. (Vol-2 Pg No.122, It No.13.33.3) Shafts & Terrace

30

310

9324

... More
code180 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. (Vol-2 Pg No.122, It No.13.33.4) Shafts & Terrace

40

390

15624

... More
code181 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. (Vol-2 Pg No.122, It No.13.33.5) Shafts & Terrace

60

500

30051

... More
code182 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. (Vol-2 Pg No.122, It No.13.33.6) Shafts & Terrace

60

757

45423

... More
code183 - Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : (Vol-2 Pg No.115, It No.13.5.3)

10

348

3486

... More
code184 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : (Vol-2 Pg No.117, It No.13.4.2) 32 mm nominal bore

8

627

5023.2

... More
code185 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : (Vol-2 Pg No.117, It No.13.4.3) 40 mm nominal bore

6

737

4422.6

... More
code186 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : (Vol-2 Pg No.117, It No.13.4.4) 50 mm nominal bore

5

897

4488.75

... More
code187 - Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (Vol-2 Pg No.123, It No.13.34)

6000

9

56700

... More
code188 - Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Vol-2 Pg No.82, It No.11.16.2)

100

154

15435

... More
code189 - Sanitary and CP fixtures : Providing, fixing, testing and commissioning CP grating for trap, complete as directed by the Engineer in charge & approved quality confiMing to ISI or BIS Standards

42

150

6300

... More
code190 - Supplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. 32mm dia CP waste coupling, 32mmdia heavy duty CP bottle trap with extension pipe, CP wall flanges, 2 Nos.15mm dia C.P. angle cocks, 2nos.C.P. flexible inlet connection pipes, CI brackets etc., complete including silicon sealant filling.

26

7897

205322

... More
code191 - Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge.

12

1850

22200

... More
code192 - Supplying and fixing PCC Pedestal 450 x 250 x 200mm with MS sloted angle iron brackets, supports with necessary drilling holes to suit the insertion of pipe clamps deburning etc., as per detailed drawing for supporting water supply pipes with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls / outer walls etc. The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08mm thick conformed to IS 1239 etc., complete as directed by the employer.

85

650

55250

... More
code193 - Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments.(5 HP, size 50x40 Head 46M, Discharge 174 LPM) Domestic Sump to OHT (Vol-2 Pg No.157, It No.13.40.5)

2

27737

55475.7

... More
code194 - Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. (Vol-2 Pg No.156, It No.13.32)

2

6825

13650

... More
code195 - EXternal Plumbing : Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. (Vol-1 Pg No.6, It No.1.4.1)

258.75

254

65748.375

... More
code196 - Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (Vol-1 Pg No.7, It No.1.11)

258.75

454

117640.6875

... More
code197 - Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete. for: Pipes of SN8 Self Fit - 160mm dia. (Vol-5 Pg No114, It No.10.3.7)

280

647

181398

... More
code198 - Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and over.(INSPECTION CHAMBER & CATCH BASIN) (Vol-5 Pg No.191, It No.16.9)

16

5726

91627.2

... More
code199 - Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber 150 x 100 mm size P type With Non Modular common burnt clay bricks of designation 3.5 & with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg asper standard design: (Vol-2 Pg No.124, It No.13.39)

6

2710

16260.3

... More
code200 - Construction of RCC Machinehole chambers of 1:1.5:3 proportion or approved type Cast-insitu / Pre-cast RCC Machinehole chambers, constructed using form vibrators of standard type, with barricading, danger lighting and using of sight rails and boning rods wherever necessary, shoring and strutting wherever required using Ordinary Port Land Cement, using 1:1.5:3 proportion RCC with 20 mm and down graded jelly, well graded sand and steel of approved quality, 200 mm thick top concrete slab, having wall thickness and raft thickness as in approved drawings and with an offset in raft alround the chamber as in approved drawing, benching concrete with 1:6 slope towards the central drain finished smooth, including fixing and grouting of pipes, including conveying to work spot supply and fixing SFRC Machinehole cover and frame (Heavy duty) conforming to IS:12592 with latest amendments, on a bed of CC 1:2:4 Providing and fixing of minimum 3 mm thick encapsulated plastic footsteps (as per IS 10910) on 12 mm dia. Grade Fe-500 steel bar (as per IS 1786) staggered at 300 mm apart as detailed in Technical specifications, including stone grit beding wherever required, watering, curing, engraving Machinehole number with flow direction on the inner cylindrical surface etc., complete including cost of reinforcement steel and fabrication charges and also cost and conveyance of all materials, labour with all lead and lifts. The Pre-cast RCC Machinehole are for various diamters and depths as stated below and as per detailed drawings, specifications and direction of the Engineer. For 1.2m dia Machinehole: Constructing Pre-cast RCC Machinehole 1.2 m internal dia. ,1.0M depth & SFRC cover & frame. (Vol-5 Pg No.194, It No.16.8.1)

2

46013

92026.2

... More
code201 - Providing and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete . (Vol-5 Pg No.86, It No.7.5) For DI/CI puddle flanges of 80mm dia.

2

1659

3318

... More
code202 - Providing and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete . (Vol-5 Pg No.86, It No.7.5) For DI/CI puddle flanges of 100mm dia

2

1954

3908.1

... More
code203 - SUMP : Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. (Vol-1 Pg No.8, It No.1.14.1)

2.32

381

884.268

... More
code204 - Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. IIn Hard Rock ( requiring blasting) Depth upto 1.50m 90% of total excavation qty (Vol-1 Pg No.9, It No.1.16.1)

20.87

581

12140.079

... More
code205 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8 (M7.5) Using 40 mm and down size graded crushed coarse aggregates. (Vol-1 Pg No.15, It No.2.1.2)

1.58

5947

9396.576

... More
code206 - Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. consider 10% of finished rate of concrete for foundation upto plitnth shuttering(Vol-1 Pg No.16, It No.2.4.3)

10.2

7318

74644.416

... More
code207 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (Vol-1 Pg No.18, It No.2.11a)

1.12

93929

105201.432

... More
code208 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Inside Walls. (Vol-II Pg No.42, It No.8.8)

25.52

389

9941.316

... More
code209 - Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. (vol -II- Page No.150, It No.15.5)

41.36

635

26273.94

... More
code210 - Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin- Charge. (vol -II- Page No.46, It No.8.12)

25.52

67

1714.944

... More
code211 - KSRB 12-6.3: Providing Cast Iron footrest and fiixng in manhole with M10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing Specification No. KBS 12.4.6. (2.18-19 SR Page No.75, It No.11.46)

8

249

1999.2

... More
code212 - Providing and fixing M.S.Inspection door of size 60 cmsx60cms including MS Frame, size 50x50x6 mm and shutters of 3mm thickness with hinges at top and locking arrangements, paintimg with all lead and lifts etc., complete. (vol -5- Page No.12, It No.7.3)

1

2247

2247

... More
code213 - STP 10 KLD: Waste Water Treatment by Prefabricated anaerobic Bio Septic tank : (For 100 Souls/10KLD) Providing, installation and commissioning of an anaerobic Bio Septic tank with all necessary accessories such as pre-filter, pipes, prefabricated RCC Tank (including internal matrix for enhanced growth of Bacteria), Anaerobic microbial Inoculum developed by DRDO and baffle wall to control the flow of water and to increase the retention time in the RCC Tank (Note: Refer to technical specification attached as Annexure-1) including cost of material, loading and unloading and as directed by the Engineer in charge etc., complete, including annual maintenance of the system for 5 years. Note :- 1. Above rates mentioned are for the purpose of preparation of estimate only. 2. All items are of ISI standards. 3. After commissioning of plant necessary testing to be done for the satisfaction of the engineer in charge. 4. Design drawing of the system suitable for erection is given in figures. STP ( 10 KLD), (Vol -5 - Page No.251, It No 22.1)

1

945000

945000

... More
code214 - Recharge Pit : Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m, 1000 MM Dia (Vol -1- Page No.5, It No.1.4.1)

12.96

254

3293.136

... More
code215 - Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m. 1000 MM Dia. (Vol -1- Page No.5, It No.1.4.2)

11.66

271

3170.937

... More
code216 - Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) (Vol -3- Page No.3)

147.74

141

20942.145

... More
code217 - Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. (Vol -2- Page No.175, It No.17.5)

54

1179

63674.1

... More
code218 - Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (Vol -2- Page No.175, It No.17.1)

1.94

1052

2041.074

... More
code219 - Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (Vol -2- Page No.175, It No.17.2)

0.97

1245

1207.941

... More
code220 - Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. (Vol -2- Page No.175, It No.17.3)

0.97

1251

1214.052

... More
code221 - Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. (Vol -2- Page No.175, It No.17.4)

0.97

1405

1363.7715

... More
code222 - Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. (Vol -2- Page No.175, It No.17.14)

6

1228

7371

... More
code223 - FIREFIGHTING : Supplying of two bucket stand alongwith buckets. Complete

2

662

1325.3

... More
code224 - Supplying and installation of RUBBER MAT 1mtr x 1mtr -10mm thick. Complete

2

1161

2323.4

... More
code225 - Smoke Detector Smoke Detector - Fully Supervised Smoke Detector, Photoelectric detection technology for superior detection sensitivity, sound and transmitted alrerts for smoke, tamper and low battery, works on powercode protocol, easy programming and enrolling to the control panel, Long life 9 votl alkaline or lithium battery simple ceiling mount installation with separate installation bracket. complete

8

4510

36082.08

... More
code226 - Wireless Siren Strobe External Wireless Siren - a fuly supervised Power Code

2

15258

30517.26

... More
code227 - Providing ABC Powder based MAP 50, 2Kg Providing 2kg Fire Extinguisher Mono Ammonium Phos phate Powder 50, Stored Pressure Type, Pressure Gauge, Gross Weight 3.6 Kg, empty weight 1.6 Kg, Can Height 344MM, Diameter 108MM, Discharge Time less than 8 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 2 meters, applicable on Class A,8, C and electrically started Fire, A Rating 1A, 8 Rating 88, Can construction : Deep drawn & Co., Mig welded, valve Construciton: Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy PoIyster power coating, Sheet metal thickness: 1.60MM, 5 years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, HOM complete as per specifications. (Vol-6, Pg No 61, It No.15.20)

4

2100

8400

... More
code228 - Supply and installation of2kg Fire Extinguisher Mono Ammonium Phosphate Powder90,Stored PressureType,Pressure Gauge,GrossWeight3.6Kg,emptyweight1.6Kg,CanHeight344MM,Diameter108MM,DischargeTimeless than8Sees,Controllable discharge mechanism(Squeezegripwitheasysnapsafetyseal),Range minimum2meters,applicableonClassA,8,CandelectricallystartedFire,ARating1A,8Rating88,Canconstruction:Deepdrawn&Co.,Migwelded, valve Construciton: Forging and Mechining,Internal Coating of Can:Epoxy powder coating,External Coating of Can:Epoxy Polyster power coating,Sheet metal thickness:1.60MM,5yearsWarranty within stalert system withS uperior quality EPDM Rubbe rHosepipeetc.,including cost of materials,labour,usage charges of machinery complete as per specifications.completeIS15683, CE Approved (Vol-6, Pg No 63, It No.15.60)

4

1850

7400

... More
code229 - BOREWELL : Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test

1

5552

5552.4

... More
code230 - Sinking of borewell of 165 mm dia clear using fast rig in all strata including over burden upto 30 M fixing of casing pipes, collars and cap with necessary cutting & threading including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes. Upto 50 Mtrs, (Vol-5, Page No.139, It No 12.1.1)

50

388

19425

... More
code231 - Sinking of borewell of 165 mm dia clear using fast rig in all strata including over burden upto 30 M fixing of casing pipes, collars and cap with necessary cutting & threading including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes. Above 50 Mtrs and upto 100 Mtr.(Vol-5, Page No.139, It No 12.1.2)

50

487

24360

... More
code232 - Sinking of borewell of 165 mm dia clear using fast rig in all strata including over burden upto 30 M fixing of casing pipes, collars and cap with necessary cutting & threading including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes. Above 100 Mtrs and upto 150 Mtr.(Vol-5, Page No.139, It No 12.1.3)

50

517

25882.5

... More
code233 - Sinking of borewell of 165 mm dia clear using fast rig in all strata including over burden upto 30 M fixing of casing pipes, collars and cap with necessary cutting & threading including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes. Above 150 Mtrs and upto 200 Mtr.(Vol-5, Page No.139, It No 12.1.4)

50

600

30030

... More
code234 - Sinking of borewell of 165 mm dia clear using fast rig in all strata including over burden upto 30 M fixing of casing pipes, collars and cap with necessary cutting & threading including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes. Above 200 Mtrs and upto 250 Mtr.(Vol-5, Page No.139, It No 12.1.5)

50

704

35227.5

... More
code235 - Sinking of borewell of 165 mm dia clear using fast rig in all strata including over burden upto 30 M fixing of casing pipes, collars and cap with necessary cutting & threading including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes. Above 250 Mtrs and upto 300 Mtr.(Vol-5, Page No.139, It No 12.1.6)

50

777

38850

... More
code236 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. b) PVC pipes 160mm dia., 6 kg/sqcm & class 3-(for casing), Vol-V- Page No.113, It No.10.1.9)

80

648

51912

... More
code237 - Borewell cap & clamp set(Accessories for pumpset installation and erectrion) Pg no.XLVII ,17(SR 2018-19 Ballary Circle )

1

1890

1890

... More
code238 - Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034 2000; 3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 3 HP etc. complete(10.00 HP - 120 LPM @ 176 m = 16 STG Outlet Dia - 2.00"), Vol-V-Page No.152, It No.13.16.6

1

50014

50014.65

... More
code239 - Providing wrought mild steel (galvanized) GI collar confirming to IS 1239-II, 1991 with latest amendments if any. Vol-V-Page No.129,It No. 11.6.11

1

729

729.75

... More
code240 - Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments.1x3x6sqmm. (Vol-V-154, It No 13.22.4)

245

194

47591.25

... More
code241 - Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments(50MM) (Vol-V-154, It No 13.24.1)

2

1312

2625

... More
code242 - Supply and delivery at site of brand new best make non-return valve asper IS 778/1984 with ISI Mark and as per its latest amendments (50MM) (Vol-V-154, It No 13.25.1)

1

1312

1312.5

... More
code243 - Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE:1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete.6 to 15 HP pumps (Vol-V-154, It No 13.24.3)

1

18375

18375

... More
code244 - Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. (Vol-V-156, It No 13.32)

1

6825

6825

... More
code245 - INTERNAL ELECTRICAL : Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. and running before Concreting the Slab. The Conduit should be tied to the reenforcement Rods by using binding wires and the unused ways of Junction boxes should be covered using PVC End enclosures .run with 18 SWG GI finish wire wherever it is necessory (Vol -VI- Pg No.2-Item No:1.2.1)19/20mm Dia 2mm Thick

1100

66

72600

... More
code246 - Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. and running before Concreting the Slab. The Conduit should be tied to the reenforcement Rods by using binding wires and the unused ways of Junction boxes should be covered using PVC End enclosures .run with 18 SWG GI finish wire wherever it is necessory (Vol -VI- Pg No.2-Item No:1.2.2)25mm dia 2mm Thick

1650

78

128700

... More
code247 - Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. and running before Concreting the Slab. The Conduit should be tied to the reenforcement Rods by using binding wires and the unused ways of Junction boxes should be covered using PVC End enclosures .run with 18 SWG GI finish wire wherever it is necessory (Vol -VI- Pg No.2-Item No:1.2.2)32mm dia 2.5mm thick

50

103

5150

... More
code248 - Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and plastering upto wall surface and .run with 18 SWG GI finish wire wherever it is necessory (Vol -VI- Pg No.2-Item No:1.3.1)19/20mm Dia 2mm Thick

1325

75

99375

... More
code249 - Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and plastering upto wall surface and .run with 18 SWG GI finish wire wherever it is necessory (Vol -VI- Pg No.2-Item No:1.3.2)25mm dia 2mm Thick

1100

80

88000

... More
code250 - Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and plastering upto wall surface and .run with 18 SWG GI finish wire wherever it is necessory (Vol -VI- Pg No.2-Item No:1.3.3)32mm dia 2.5mm thick

50

105

5250

... More
code251 - Supplying and fixing PVC/ Metal Conduit Deep Junction Boxes (Vol -VI- Pg No.3-Item No:1.5.1)19/20 mm Deep Junction Box

110

49

5390

... More
code252 - Supplying and fixing PVC/ Metal Conduit Deep Junction Boxes (Vol -VI- Pg No.3-Item No:1.5.2)25 mm Deep Junction Box

150

51

7650

... More
code253 - Supplying and fixing PVC/ Metal Conduit Deep Junction Boxes (Vol -VI- Pg No.3-Item No:1.5.2)32 mm deep Junction Box

20

69

1380

... More
code254 - Supplying and fixing PVC Casing and capping on the wall or ceiling using materials like bend , screws at an interval 0f 300 mm etc (Vol -VI- Pg No.3-Item No:1.8.1)20 mm

200

28

5600

... More
code255 - Supplying and fixing PVC Casing and capping on the wall or ceiling using materials like bend , screws at an interval 0f 300 mm etc (Vol -VI- Pg No.3-Item No:1.8.2)25 mm

200

35

7000

... More
code256 - Supplying and fixing PVC Casing and capping on the wall or ceiling using materials like bend , screws at an interval 0f 300 mm etc (Vol -VI- Pg No.3-Item No:1.8.3)32 mm

50

43

2150

... More
code257 - Supplying PVC /GI flexible conduit pipe …. Mm dia fixing on surface cover inverted tapared wodden plugs or phill plugs or rawl plugs and clamped using heavy guage saddles in an interval of 300 mm using NF screws and on the eaiter end of the pipe terminated properly (Vol -VI- Pg No.3-Item No:1.9.1)20 mm

200

19

3800

... More
code258 - Supplying PVC /GI flexible conduit pipe …. Mm dia fixing on surface cover inverted tapared wodden plugs or phill plugs or rawl plugs and clamped using heavy guage saddles in an interval of 300 mm using NF screws and on the eaiter end of the pipe terminated properly (Vol -VI- Pg No.3-Item No:1.9.2)25 mm

200

22

4400

... More
code259 - Extra length of GI pipe of class B 19mm dia for down rod. (Vol -VI- Pg No.57-Item No:13.12)

55

197

10835

... More
code260 - Supply & Fixing of Metal fan box with round Hook (Vol -VI- Pg No.4-Item No:1.13)

50

117

5850

... More
code261 - Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet. Make : KEI / Polycab/ Finolex(Vol -VI- Pg No.5-Item No:2.2.1)Short point upto 3 Mtd. From Tapping point to outlet via switch box.

40

269

10760

... More
code262 - Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet. Make : KEI / Polycab/ Finolex(Vol -VI- Pg No.5-Item No:2.2.2)Medium point above 3 Mts upto 6 Mts. From tapping point to outlet via switch box.

110

379

41690

... More
code263 - Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet. Make : KEI / Polycab/ Finolex(Vol -VI- Pg No.5-Item No:2.2.3)Long point above 6 Mts. Upto 10 Mts. From tapping of point to outlet via switch box.

85

555

47175

... More
code264 - Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet. Make : KEI / Polycab/ Finolex(Vol -VI- Pg No.5-Item No:2.2.4)Two outlet in a row above 3 Mts upto 6 Mts, from tapping point to outlet via switch box.

15

677

10155

... More
code265 - Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet. Make : KEI / Polycab/ Finolex(Vol -VI- Pg No.5-Item No:2.2.5)Three outlet in a row, above 6 Mts. Upto 10 Mts. From tapping point to outlet via switch box.

15

989

14835

... More
code266 - Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring (Vol -VI- Pg No.5-Item No:2.3.2) 1.5 Sqmm

2800

26

72800

... More
code267 - Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring (Vol -VI- Pg No.5-Item No:2.3.3)2.5Sqmm

8000

42

336000

... More
code268 - Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring (Vol -VI- Pg No.5-Item No:2.3.4)4Sqmm

1200

63

75600

... More
code269 - Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring (Vol -VI- Pg No.5-Item No:2.3.5)6 sqmm

600

92

55200

... More
code270 - Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring (Vol -VI- Pg No.5-Item No:2.3.6)10Sqmm

250

167

41750

... More
code271 - Switches Sockets and Accessories:Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall (Vol -VI- Pg No.8-Item No:3.4.1)1-3 way

80

138

11040

... More
code272 - Switches Sockets and Accessories:Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall (Vol -VI- Pg No.8-Item No:3.4.2)4-5 way

100

177

17700

... More
code273 - Switches Sockets and Accessories:Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall (Vol -VI- Pg No.8-Item No:3.4.3)6 way

130

220

28600

... More
code274 - Switches Sockets and Accessories:Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall (Vol -VI- Pg No.8-Item No:3.4.4)8 way

40

261

10440

... More
code275 - Switches Sockets and Accessories:Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall (Vol -VI- Pg No.8-Item No:3.4.5)12 way

30

319

9570

... More
code276 - Switches Sockets and Accessories:Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall (Vol -VI- Pg No.8-Item No:3.4.6)16 way

10

363

3630

... More
code277 - Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box (Vol -VI- Pg No.8-Item No:3.5.1)1-3 way

80

161

12880

... More
code278 - Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box (Vol -VI- Pg No.8-Item No:3.5.2)4-5 way

100

175

17500

... More
code279 - Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box (Vol -VI- Pg No.8-Item No:3.5.3)6 way

130

234

30420

... More
code280 - Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box (Vol -VI- Pg No.8-Item No:3.5.4) 8 way

40

284

11360

... More
code281 - Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box (Vol -VI- Pg No.8-Item No:3.5.5)10-12 way

30

344

10320

... More
code282 - Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box (Vol -VI- Pg No.8-Item No:3.5.6)16 way

10

397

3970

... More
code283 - Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate (Vol -VI- Pg No.9-Item No:3.6.1) 6 Amp one way

250

102

25500

... More
code284 - Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate (Vol -VI- Pg No.9-Item No:3.6.2) 6 Amps 2 way

8

166

1328

... More
code285 - Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate (Vol -VI- Pg No.9-Item No:3.6.3) 6 Amps socket

160

171

27360

... More
code286 - Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate (Vol -VI- Pg No.9-Item No:3.6.4) Stepped Fan Regulator

50

357

17850

... More
code287 - Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate (Vol -VI- Pg No.9-Item No:3.6.8)16 Amps 1 way switch

100

180

18000

... More
code288 - Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate (Vol -VI- Pg No.9-Item No:3.6.9)6 Amps Bell Push

2

177

354

... More
code289 - Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate (Vol -VI- Pg No.9-Item No:3.6.10)32 Amps DP Switch

10

326

3260

... More
code290 - Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate (Vol -VI- Pg No.9-Item No:3.6.11)6/16 Amps universal socket

40

236

9440

... More
code291 - PANEL:Fabrication and supply of sheet steel enclosure out of 14 SWG CRCA Sheet duly powder coated the contro panel ( Size of 2000 x1500x 450 ) is of compartment alized, All the components are duly wired and connected to Aluminum bus bar. (Vol -VI- Pg No.20-Item No:5.42.1)

45000

-

22500

... More
code292 - Supplying and fixing of 250 A 4 x 30 x 10 mm Alumunium Strips (Vol -VI- Pg No.20-Item No:5.40.2)

12

3435

41220

... More
code293 - 16 sqmm wire (Vol -VI- Pg No.6-Item No:2.3.7)

40

318

12720

... More
code294 - Supplying and fixing of LED Panel Board indicating Lamp with required colour Suitable for 220 V AC 50 HZ (Vol -VI- Pg No.19-Item No:5.38)

6

515

3090

... More
code295 - Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 A three phase 4 wire whole current class-1 Accuracy Energy Meter. (Vol -VI- Pg No.19-Item No:5.35)

8

5705

45640

... More
code296 - Supplying of on load change over switches 4 poles, AC- 23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution) 200A (Vol -VI- Pg No.15-Item No:5.12.4)

1

15249

15249

... More
code297 - ACCL 40A DG Supply TPN (Vol -VI- Pg No. -Item No:5.53.1)

10

10500

105000

... More
code298 - Supplying and fixing of 160 A MCCB (Vol -VI- Pg No. -Item No:5.14.9)

1

13447

13447

... More
code299 - 63A 4P MCB (Vol -VI- Pg No. -Item No:5.17.9)

6

3088

18528

... More
code300 - 5 - 32 A TPN (Vol -VI- Pg No. -Item No:5.17.9)

8

1717

13736

... More
code301 - Supplying,fixingandwiringearthleakagerelaywithcorebalancedcurrenttransformersuitableforsinglephase50HzACwithlatestmicrocontrollerbased,digitalreadoutofpercentageleakagecurrent,programmabledelay/auto/manualresetfacilitysuitabletomountonDIN rail/ flush mounting on panel board. (Vol -VI- Pg No.18 -Item No:5.21)

1

9255

9255

... More
code302 - SupplyingandfixingangleironframeworkfabricatedoutofM.S.angleiron..andM.S.Flat......withbolts,washersetc.,andpaintedwith 2 coats of red oxide and then two coats of approved paint. 50 x 50 x 6 mm Angle (Vol -VI- Pg No. 20-Item No:5.41.2)

10

395

3950

... More
code303 - Distribution boards:Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting (Vol -VI- Pg No.18 -Item No:5.19.6) 4Way SP &N

1

1524

1524

... More
code304 - Distribution boards:Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting (Vol -VI- Pg No. 18-Item No:5.19.8)8Way SP &N

1

1854

1854

... More
code305 - Distribution boards:Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting (Vol -VI- Pg No.18 -Item No:5.19.9)12Way SP &N

6

2329

13974

... More
code306 - Distribution boards:Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting (Vol -VI- Pg No.18 -Item No:5.19.12)6Way TP &N

6

4940

29640

... More
code307 - Supplying fixing & wiring earth leakage miniature circuit breaker (ELMCB) 240 / 450 V up to 300mA sensitivity on Existing / panel Board (Vol -VI- Pg No.18 -Item No:5.20.1)16 - 25 Amps 2 pole

6

4277

25662

... More
code308 - Supplying fixing & wiring earth leakage miniature circuit breaker (ELMCB) 240 / 450 V up to 300mA sensitivity on Existing / panel Board (Vol -VI- Pg No.18 -Item No:5.20.2)32 - 40 Amps 2 pole

18

4559

82062

... More
code309 - Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898 (Vol -VI- Pg No.17 -Item No:5.18.1)5 - 32 Amp SP

185

415

76775

... More
code310 - Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898 (Vol -VI- Pg No.17 -Item No:5.18.2)40 - 63 Amps SP

4

811

3244

... More
code311 - Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898 (Vol -VI- Pg No.17 -Item No:5.18.4)5 - 32 Amp DP

2

739

1478

... More
code312 - Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898 (Vol -VI- Pg No.17 -Item No:5.18.7)5 - 32 A TPN

6

1717

10302

... More
code313 - Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898 (Vol -VI- Pg No.18-Item No:5.18.9)40 - 63 Amp TPN

2

3088

6176

... More
code314 - ELECTRICAL FIXTURES:Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W (Vol -VI- Pg No.43 -Item No:11.3.2)

120

690

82800

... More
code315 - Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K, CRIGreater than 70%. efficacy Greater than 100 lumen per W, 120degree beam spread, lifeGreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF Greater than 0.95, power loss shouldLess than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2'-34-36W (Vol -VI- Pg No.45 -Item No:11.6.3)

22

4553

100166

... More
code316 - Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition. LED square or round down light 15-18W (Vol -VI- Pg No.44 -Item No:11.5.3)

60

1324

79440

... More
code317 - Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. (Vol -VI- Pg No.30 -Item No:6.1)

20

1492

29840

... More
code318 - Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty. 48" Sweep 5 Star (1200 mm) (Vol -VI- Pg No.30 -Item No:6.4.1)

50

2677

133850

... More
code319 - Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. (Vol -VI- Pg No.56 -Item No:13.7.1)

202

119

24038

... More
code320 - Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. (Vol -VI- Pg No.57 -Item No:13.10)

50

171

8550

... More
code321 - Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. (Vol -VI- Pg No.57 -Item No:13.14)

20

492

9840

... More
code322 - SERVICE MAINS & WORK UNDER UG CABLE , EARTHING:Supplying Fixing and Wiring earth electrode for grounding of lifts,Xmer, DG Sets etc using 40mm dia 2.9mm thick, 2.5mtr long GI pipe with GI funnel with mesh & suitable size reducer fixed on the top of Electrode. The funnel should be enclosed in a cc chamber of 400x400x400 with a cast iron cover. The Earth electrode shall have staggered holes of 12mm dia & electrode shoulde be covered 150mm around with alternate layers of salt & charcoal from the bottom of the CC Chamber. The connection from the electrode is to be established throgh GI strip using GI bolts & nuts. (Vol -VI- Pg No.54 -Item No:12.57)

6

4256

25536

... More
code323 - 25 x 3 mm G.I strip.(Vol -VI- Pg No. -Item No:6.3.1)

80

82

6560

... More
code324 - 600x600x3 GI Plate (Vol -VI- Pg No. -Item No:6.3.5)

2

760

1520

... More
code325 - Cu. Strip 25 x 3 mm (Vol -VI- Pg No. -Item No:6.3.6)

50

505

25250

... More
code326 - Cu. Strip 600x600x3 Cu. Plate (Vol -VI- Pg No. -Item No:6.3.10)

2

6900

13800

... More
code327 - 12 SWG GI wire (Vol -VI- Pg No. -Item No:6.3.10)

200

14

2800

... More
code328 - 12 SWG (Vol -VI- Pg No. -Item No:6.18.4)

50

58

2900

... More
code329 - 10 SWG (Vol -VI- Pg No. -Item No:6.18.5)

50

68

3400

... More
code330 - 8 SWG (Vol -VI- Pg No. -Item No:6.18.6)

50

105

5250

... More
code331 - 2C x 10sq.mm. Al. Alum. Cable (Vol -VI- Pg No. -Item No:6.4.1)

100

95

9500

... More
code332 - 4C x 10sq.mm. Al. Alum. Cable (Vol -VI- Pg No. -Item No: 6.4.2)

60

130

7800

... More
code333 - 4C x 16sq.mm. Al. Alum. Cable (Vol -VI- Pg No. -Item No:6.4.3)

100

150

15000

... More
code334 - 3.5C x 120sq.mm. Al. Alum. Cable (Vol -VI- Pg No. -Item No:6.4.10)

100

600

60000

... More
code335 - Supply & Fixing of Heavy Duty Cable Glands Suitable For UG Cable of 1.1KV Class (metal Only) (Vol -VI- Pg No. -Item No:6.11.2)25mm Dia

30

84

2520

... More
code336 - Supply & Fixing of Heavy Duty Cable Glands Suitable For UG Cable of 1.1KV Class (metal Only) (Vol -VI- Pg No. -Item No:6.11.6)63mm Dia

8

388

3104

... More
code337 - Supplying Tinned Cu. Lugs & crimping & wiring to terminal Point for Wire of following sizes (Vol -VI- Pg No. -Item No:6.17.6) 16sq.mm. long Barrel

18

12

223.92

... More
code338 - Supplying Tinned Cu. Lugs & crimping & wiring to terminal Point for Wire of following sizes (Vol -VI- Pg No. -Item No:6.17.15) 240Sqmm Long Barrel

6

463

2778

... More
code339 - Supplying Tinned Cu. Lugs & crimping & wiring to terminal Point for Wire of following sizes (Vol -VI- Pg No. -Item No:6.17.12)120 Sqmm Long Barrel

50

190

9500

... More
code340 - Supply & Fixing 2mm thick perforated cable tray with powder coated paint on exising MS Angle support using necessary GI bolts , nuts & washer or welding as required: (Vol -VI- Pg No. -Item No:6.16.1)150 mmX 50 MM wide tray ( Perforated type )

5

425

2125

... More
code341 - Supply & Fixing 2mm thick perforated cable tray with powder coated paint on exising MS Angle support using necessary GI bolts , nuts & washer or welding as required: (Vol -VI- Pg No. -Item No:6.16.2)300 mm x 50 mm wide cabel tray ( Perforated type )

5

530

2650

... More
code342 - UPS & BATTERIES:2KVA offline UPS (Vol -VI- Pg No. -Item No:9.2.3)

4

21293

85172

... More
code343 - 150 AH capacity (Vol -VI- Pg No. -Item No:9.5.9)

8

15895

127160

... More
code344 - Fabricating, supplying and erection of ...Mtrs long hot dip Galvanized Octagonal pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47m/sec for …….Mtrs pole in single section and single joint welded as per IS 9595/IS 10178AWS having dimensions bottom …..mm, top….mm with 3/4mm thick, suitable base plate and 4Nos of ..... long J bolts along with template and the pole shall be galvanized with not less than 65micron etc as per ASTM-A 123 and 153 etc., (excluding foundation) as per drawing appended. a)3 Meters-Top 70mm and bottom 130mm dia. Vol -VI -Page No.11 It No 4.2.1

4

6300

25200

... More
code345 - Fabricating, supplying and erection of ...Mtrs long hot dip Galvanized Octagonal pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47m/sec for …….Mtrs pole in single section and single joint welded as per IS 9595/IS 10178AWS having dimensions bottom …..mm, top….mm with 3/4mm thick, suitable base plate and 4Nos of ..... long J bolts along with template and the pole shall be galvanized with not less than 65micron etc as per ASTM-A 123 and 153 etc., (excluding foundation) as per drawing appended. b)5 Meters-Top 70mm and bottom 130mm dia (Vol VI , Pg No.11.It-No.4.2.4)

4

9900

39600

... More
code346 - Supply Of Led Street Light Luminaire With Pressure Die Cast Aluminium Housing Body For Optima Lthermal Dissipation.Lamp Compartment Comprising Of Anti Glare Clear Diffuser With Injection Moulded Polycarbonate Material,Delivering Superior Light Output Rated Life Burning Hrs50000Hr@Lumen Maintenance Of 70%,Maximum Light Intensity Should Be Between 60Degreesto70Degrees.CctGreater than5500K,Ip66 Optical And Electrical Ompartment &Impact Resistance Of Complete LuminaireGreater thanIk08.PowerfactorGreater than0.9With Mains,Surge Protection-Min5Kvalong With Overvoltage/Overload,Shortcircuit/Miss-Wiring Protection.Compatible For Pole Mounting With Outer Dia Of 40Mmto50Mm.Universal Voltage Drivert Ooperate Wide Voltage Range From100Vto270V50/60Hz application.Compliancetois10322/Iec60598,Lm79&Lm 80 Adherence With Rohs. Ul Approved Mcpcb. Top Access Street Light With Single screwtoensureeaseofmaintenanceatthesightsitelocationwithminimizedminimaltools.Ledlightfixturewith........Wsystempowerconsumption.LedefficiencyGreater than1301M/W,NominalcriGreater than75.Luminairemanufacturershouldhavein-Housefacilityaccreditedbynabl/Cpri&Anygovernmentcertifiedagency&Design&Developmentfacilitycertifiedbyiso9001:2008.Housingwithsupplierwordmark/Nameshallbeengraved/Embossingonthediecasthousing/Bodypart.Warrantyof2Yearsagainstanymanufacturingdefectworkingunderstandardelectricalconditionsasmentionedaboveshouldbegivenbyledmanufacturer&Cree/Nichia/Lumileds/Osram Make Led Source. Led Street Light70 Watts . Vol Vi- Page No.45, It No 11.8.3

8

5992

47936

... More
code347 - 4C x 16sq.mm. Al. Alum. Cable

100

150

15000

... More
code348 - Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., complete

100

102

10200

... More
code349 - Labour charges for laying of 1.1 KV class UG cable when supplied agency in existing trench GI pipe / stoneware pipe / on wall / on pole as required.(69/5) - In exixting trench/duct. 6sqmm to 16 sqmm

100

11

1180

... More
code350 - Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable (Sl no 7.10 page no 62)

100

100

10000

... More
code351 - Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 Sqmm

26

12

323.44

... More
code352 - SupplyingheavygaugePVCconduitpipe.......dia.......mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws. 25mm Dia, Vol VI- Page No.2, It No 1.1.2

100

81

8100

... More
code353 - SupplyofLEDfloodlightluminairewithpressurediecastaluminiumhousingbodyforoptimalthermaldissipation.LampcompartmentcomprisingofantiglarecleardiffuserwithInjectionmouldedpolycarbonate/clearglassmaterial,deliveringsuperiorlightoutputRatedlifeBurningHrs50000hr@LumenMaintenanceof70%,CCTGreater than5500K,IP66opticalandelectricalcompartment&impactresistanceofcompleteluminaireGreater thanIK08.PowerFactorGreater than0.9withmains,SurgeProtection-Min5KValongwithOvervoltage/Overload,shortcircuit/miss-wiringprotection.Compatibleforpolemaulingwithouterdiaof40mmto50mm.UniversalVoltagedrivertooperatewidevoltagerangefrom100Vto270V50/60Hzapplication.CompliancetoIS10322/IEC60598,LM79&LM80AdherencewithRoHS.ULapprovedMCPCB.Topaccessstreetlightwithsinglescrewtoensureeaseofmaintenanceatthesightsitelocationwithminimizedminimaltools.LEDLightfixturewith.......WSystemPowerconsumption.LEDEfficiencyGreater than1301m/w,nominalCRIGreater than75.Luminairemanufacturershouldhavein-housefacilityaccreditedbyNABL/CPRI&anyGovernmentcertifiedagency&Design&DevelopmentfacilitycertifiedbyISO9001:2008.Housingwithsupplierwordmark/nameshallbeEngraved/Embossingonthediecasthousing/BodypartWarrantyof2YearsagainstanymanufacturingdefectworkingunderstandardelectricalconditionsasmentionedaboveshouldbegivenbyLEDmanufacturer&Cree/Nichia/Lumileds/Osrammake LED Source. 70 Watt Led Flood light. Vol - VI- Page No 46. It No 11.9.1

4

6768

27072

... More
code354 - Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to table 3 class 5 of IS:8130- 1984 and (Virgin) PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 & confirming to GTP of GROUP-A. 4C x 2.5 sqmm ( Vol- VI-Page No.6, It No2.5.9

200

148

29600

... More
code355 - Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting. III. Double Door, 6Way TP &N. Vol-VI, Page No-18, It No 5.19.2

1

4940

4940

... More
code356 - Supplying fixing & wiring earth leakage miniature circuit breaker (ELMCB) 240 / 450 V up to 300mA sensitivity on Existing / panel Board. 16 - 25 Amps 2 pole. Vol-VI, Page No-18, It No 5.20.1

3

4277

12831

... More
code357 - Supplying&fixingminiaturecircuitbreakersonexistingMCBdistributionboardsusingnecessaryfixingmaterialsand'C'Typecurve,indicatorON/OFF,energycross-3withShortcircuitbreakingcapacityof10KandcompletewiringasrequiredconfirmingtoIEC60898. VOL-VI, Pg no 17, It No.5.18.1. 6 - 32 Amp SP

4

415

1660

... More
code358 - Supplying&fixingminiaturecircuitbreakersonexistingMCBdistributionboardsusingnecessaryfixingmaterialsand'C'Typecurve,indicatorON/OFF,energycross-3withShortcircuitbreakingcapacityof10KandcompletewiringasrequiredconfirmingtoIEC60898. VOL-VI, Pg no 17, It No.5.18.1.50-63 A SP

4

811

3244

... More
code359 - Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. andfixing using invetred wood plugs in Case of RCC ceiling and RCC wall /stone structure or rawl plug incase of brick wal ls and cement plastering the damaged portion using heavy guage saddles in an intervel of 700 mm using NF Screws (Vol -VI- Pg No.2 -Item No:1.1.1)19/20mm Dia 2mm Thick

600

69

41400

... More
code360 - Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. andfixing using invetred wood plugs in Case of RCC ceiling and RCC wall /stone structure or rawl plug incase of brick wal ls and cement plastering the damaged portion using heavy guage saddles in an intervel of 700 mm using NF Screws (Vol -VI- Pg No.2 -Item No:1.1.2)25mm dia 2mm Thick

1200

81

97200

... More
code361 - Supplying and drawing pvc insulated gas injected p hysical foam jelly filled co axial TV Cable Rg6 (Vol -VI- Pg No.36 -Item No:8.3)

100

44

4400

... More
code362 - 4 Pair Telephone wire (Vol -VI- Pg No.36 -Item No:8.2.4)

1225

35

42875

... More
code363 - Supplying & drawing UTP Cat 6 E Lan Cable (Vol -VI- Pg No.36 -Item No:8.1)

3900

38

148200

... More
code364 - Single I/0 (Vol -VI- Pg No.36 -Item No:8.10.1)

60

490

29400

... More
code365 - Double I/O (Vol -VI- Pg No.37 -Item No:8.10.2)

6

550

3300

... More
code366 - T.V telephone Socket (Vol -VI- Pg No.9 -Item No:3.6.11)

65

156

10140

... More
code367 - 42U with 650mm depth(Vol -VI- Pg No.36 -Item No:8.4.10)

1

43168

43168

... More
code368 - Supplying & Fixing of power Strip (Vol -VI- Pg No.36 -Item No:8.5)

2

1457

2914

... More
code369 - 24 port 10 / 100 /1000 Switch (Vol -VI- Pg No.36 -Item No:8.9.10)

6

7415

44490

... More
code370 - 1 Mtr patch cable (Vol -VI- Pg No.37 -Item No:8.11.1)

75

224

16800

... More
code371 - 2 Mtr patch cable (Vol -VI- Pg No.37 -Item No:8.11.2)

75

257

19275

... More
code372 - 24 port 10 / 100 patch panel (Vol -VI- Pg No.37 -Item No:8.12.2)

6

4100

24600

... More
code373 - Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination. (Vol -VI- Pg No.37 -Item No:8.13.4) 50 pair

2

631

1262

... More
code374 - CCTV SURVEILLANCE SYSTEM: Supply, erection, testing and commissioning of CCTV Surveillance System as per specification , NOTE: Based on lowest quotation rate of M/s Nivosys technologies, Indoor Dome IR Camera, HD Video

12

6900

82800

... More
code375 - Outdoor Bullet- 25 Mtrs Range, HD Video

2

7500

15000

... More
code376 - Power Supply 12VDC, Each Supports upto 5 IR Cameras

5

3300

16500

... More
code377 - 16 Channel DVR, HD, with 2TB Surveillance HDD

1

57000

57000

... More
code378 - 19 INCH Color Monitor For DVR

1

10440

10440

... More
code379 - CCTV Cabling including PVC Conduit

700

114

79800

... More
code380 - AIR CONDITIONERS : Supplying ......TR split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacitors, relay and over load protector internal unit, with one indoor and one outdoor unit The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube. (High wall chorded/cordless) suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit. 1.5 Ton capacity, Vol - VI- Page No 31, It No 6.8.5

2

56355

112710

... More
code381 - Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type. Vol - VI- Page No 32, It No 6.12

2

3175

6350

... More
code382 - Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3core 80 stand copper wiring between indoor and outdoorunit Leak testing oil and gas charging for additional piping. Split. Vol - VI- Page No 32, It No 6.13

20

1549

30980

... More
code383 - Supplying and drawing Flexible Multicore Cable manufacture with electrolytic grade flexible copper with low conductor confirming to IS8130- 984 and(Virgin)PVC insulations heat hed suitable forworking voltage upto 1100 Volts as per IS-694:1990 3C x 4 sqmm Copper flexible cable. Vol - VI- Page No 6.3 , It No 2.5.15

50

172

8600

... More
code384 - LIFT : Design,supplying,erecting testing and commissioning of-Passenger /Bed -cum-passenger hospital lift with speed of 1mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415V 3phase 50cycles ACsupply ,powder coated/Stainless Steel car entrance doors enclosure swith suitable colour vinyl flooring, LED carillumination, emergency light, intercom and fan as desired by the user,central opening/ side opening door with or without attendant operation,7segment display buttons,call register indicator, fire man drive, SS handrails inside car, full length infrared curtain in cardoor, automatic rescue device with batteries, voice announcing inr egional /international languages ,Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, ounter weight etc., The total product and services shall adhere to IS14665/2016 (with latest amendments)part/section1 to with regards to general guidelines of fire safety rated doors ,MRLL beams, pressure switch, manual change over for doors during emergency, ARD of 10times with sufficient battery back up and standard dimensions of chair car and door openings for all sizes and capacities of lifts including fitness certificate and duly observing all other safety norms prescribed and adhere to CPWD specifications, PCB Norms, National Electricity Code (NEC), NBC-2016, IEC and Karnataka State Lifts, Escalators and Passengers Conveyers Act 2012 and Rules 2014. The Supplier shall be registered in Government Electrical Inspectorate in the State of Karnataka. WITHOUT MACHINE ROOM SS FINISH, 8 PASSANGER - 3 STOPS. SL.NO-14.4.1, PG.NO-59, VOL-6.

1

1531416

1531416.56

... More
code385 - EXTERNAL Electrical : PART A- Providing 2 Pole Structure at tapping Point from the existing feeder RCC DP Structure Using 9mtrs RCC Pole WL- 45kg

1

20928

20928

... More
code386 - 11 KV, 5KN polypin insulators 24mm dia FRP Rod

6

205

1230

... More
code387 - 11 KV, 45KN polypin insulators

6

186

1116

... More
code388 - Guy Set Complete complete with No.15 strain insulator and concreting materials

2

1170

2340

... More
code389 - Caution/Danger Board

1

150

150

... More
code390 - Anti Climbing Device (12mtrs GI Barbed Wire)

2

89

178

... More
code391 - 11kV, 250Amps, Double Break GOS

1

21260

21260

... More
code392 - H - Frame Set for Mounting - GOS

1

4332

4332

... More
code393 - Spiral Earth Electrodes

2

239

478

... More
code394 - 11KV Lightning arrestors - Metal oxide 9KV, 5KA polymeric type with ground connector (set of 3Nos)

1

4752

4752

... More
code395 - Earthing materials Pipe tyep for Grounding

1

1729

1729

... More
code396 - 11KV DOLO Cut out (Set / 3NOs)

1

5872

5872

... More
code397 - Erection of 9mtrs RCC DP Structure

1

5372

5372

... More
code398 - Fixing of Guy Set Complete with No.15 strain insulator and all accessories like turn buckle

2

593

1186

... More
code399 - Fixing of Caution/Danger Board

1

80

80

... More
code400 - Fixing of Anti Climbing Device

2

42

84

... More
code401 - Fixing of 250Amps, Double Break GOS

1

1214

1214

... More
code402 - Erection of H - Frame Set for Mounting - GOS

1

323

323

... More
code403 - Fixing of Spiral Earth Electrodes

2

93

186

... More
code404 - Fixing of Lightning arrestors

1

119

119

... More
code405 - Providing Earthing

1

949

949

... More
code406 - Fixing of DOLO Cut out

1

237

237

... More
code407 - Loading & Unloading of Poles :9mtrs long

2

960

1920

... More
code408 - GUY Concreteing with boulders & Sand

2

250

500

... More
code409 - Painting of 9mtrs long RCC poles: a) Base Concreting CC 1:4:8, 500x650x150mm

2

3434

6868

... More
code410 - b) Pole concreting CC 1:2:4 , 650x500x1700mm

2

312

624

... More
code411 - c) Pole coping CC 1:2:4 , 150mm alround pole for an height of 300mm

2

312

624

... More
code412 - PART B- Extension of 11 KV 3 Phase Power line from the existing feeder/ sub-station using Rabbit ACSR Conductor with an average span of 40Mtrs. RCC pole 9mtr long 145 Kg WL

3

7076

21228

... More
code413 - Horizontal cross arms with clamps, HTST supports, bolts, nuts and washers for RCC poles

3

646

1938

... More
code414 - 11kV KN polymeric Pin insulator 24mm Dia FRP rod.

9

205

1845

... More
code415 - 11kv , 45kN Polymeric insulator

9

186

1674

... More
code416 - Guyset complete with No 15 strain insulator and concreting Materials.

3

1170

3510

... More
code417 - Rabbit ACSR conductor

0.3

46234

13870.2

... More
code418 - Rabbit Conductor accessaries at 3% on above

0.3

1387

416.1

... More
code419 - PG Clamps for Rabbit conductor

20

102

2040

... More
code420 - Spiral Earth Electrode

3

239

717

... More
code421 - EG Stirrups with GI wire lacing (set/3Nos)

3

276

828

... More
code422 - Caution /Danger board

3

150

450

... More
code423 - Anti climbing device (12mtrs/ 1 Kg GI Barbed Wire)

1

89

89

... More
code424 - Erection of 9mtrs RCC DP Structure

3

1752

5256

... More
code425 - Fixing Horizontal cross arms

3

272

816

... More
code426 - Fixing of Guy Set Complete with No.15 strain insulator and all accessories like turn buckle

3

593

1779

... More
code427 - Stringing of Rabbit ACSR Condutor

0.3

4361

1308.3

... More
code428 - Fixing of Spiral Earth Electrodes

3

93

279

... More
code429 - Fixing of Anti Climbing Device

3

42

126

... More
code430 - Fixing of EG stirrups with GI wire

3

160

480

... More
code431 - Fixing of caution/danger board

3

80

240

... More
code432 - Guyset Concreting with boulders mud & sand

3

250

750

... More
code433 - Concreting materials for 9 mts RCC poles

3

960

2880

... More
code434 - Base concerting 1:4:8, 500 x 650 x 150 mm

3

312

936

... More
code435 - Cople concreting in CC 1:2:4 650 X 500 700mm

3

3434

10302

... More
code436 - Pole coping in CC 1:2:4 and as per actnals 150mm alround the pole for an height of 300mm

3

312

936

... More
code437 - PART C- Erection of 3Phase , 11KV/433Volts,100kVA BEE 5 Star rated Distribution Transformer center Using Double pole Transformer Structure(D.P.T.S), 9 mts RCC DP transformer structure using 9 mts RCC poles

1

31554

31554

... More
code438 - 11 KV, 5 KN polymetric Pinindulators (24 mm dia FRP rod)

3

205

615

... More
code439 - 11KV -45 KN polymetric insulators

3

186

558

... More
code440 - Guyset complete with 15 strain insulator and concreting materials.

4

1170

4680

... More
code441 - 11 KV/433V , 100 KVA,3 phase ,50cycles Distrubtion transformer BEE-5 star rated with oil

1

221952

221952

... More
code442 - Earthing materials pipe type for grounding

4

1729

6916

... More
code443 - caution/Danger boards

2

150

300

... More
code444 - Anticlimbing devices with barbed wire

2

89

178

... More
code445 - Concreting materials for guyset without cement.

2

250

500

... More
code446 - GI wire 8 SWG

5

75

375.2

... More
code447 - Guy wire 7/10 SWG

10

77

772.3

... More
code448 - 11 KV Lightning arrestors metal oxide 9kv , 5KA

1

4752

4752

... More
code449 - LT Distribution Box for 100KVA with MCCB

1

22686

22686

... More
code450 - LT matering Box with CTS an necessary wiring for housing ETV meter

1

5126

5126

... More
code451 - LT electronic tri-victor meter 5A class-0.5 (1.0 accuracy)

1

3396

3396

... More
code452 - 11 KV soli core type HG tuse unit (set/3 Nos)

3

1069

3207

... More
code453 - 11 KV 200 Amps single Break GOS

1

9450

9450

... More
code454 - concreting materials for mts RCC poles of DP set a) Base concreting 1:4:8 500x650 x150 mm

2

312

624

... More
code455 - Pole concreting 1:2:4,650 x 500 x1700 mm

2

3434

6868

... More
code456 - Coping in CC 1:2:4 and as per actuals 150mm alround the pole for an height of 300mm

2

312

624

... More
code457 - Painting of 9 Mts RCC DP structure poles

2

960

1920

... More
code458 - LT wiring KIT

1

10080

10080

... More
code459 - Erection of 9mts RCC DP transformer Structure

1

6983

6983

... More
code460 - Fixing of guyset

2

593

1186

... More
code461 - Erection of 100 KVA Distribution transformer

1

1590

1590

... More
code462 - Fixing earthings

4

949

3796

... More
code463 - Fixing of cauton/danger board

2

80

160

... More
code464 - Providing Anticlimbing devices

2

42

84

... More
code465 - Providing of lightning arrestors

3

119

357

... More
code466 - Fixing of LT Distribution Box

1

385

385

... More
code467 - Fixing of LT Wiring kit

1

949

949

... More
code468 - Fixing of LT matering Box

1

863

863

... More
code469 - Fixing of LT electronic tri-vector meter

1

480

480

... More
code470 - Fixing of 11 KV Soli core type HG fuse unit

3

337

1011

... More
code471 - Fixing of 200 amps/S/B GOS

1

1104

1104

... More
code472 - PART D- Laying of 11 KV 3 Core 95 Sqmm XLPE UG Cable Using Conventional laying with excavation of Soil. 11 KV class 3 c x 95 Sqmm x LPE UG cable (Flat armoured)

0.1

889666

88966.6

... More
code473 - Cable termination Kit outdoor HS type Suitable for 95 Sqmm cable

1

4077

4077

... More
code474 - Cable termination Kit indoor type Suitable for 95Sqmm cable

2

3744

7488

... More
code475 - RCC hume pipe 2000 mm long 150mm dia

40

307

12280

... More
code476 - Collars for RCC hume pipes

4

82

328

... More
code477 - GI pipe 100 mm dia for cable rising

3

1235

3705

... More
code478 - Route and joint indicating stores

5

133

665

... More
code479 - Laying of cable in trench in wherever necessary

80

61

4905.6

... More
code480 - Without HDPE Pipe

20

949

18980

... More
code481 - Making of cable terminations

2

2658

5316

... More
code482 - Laying of RCC Hume pipes

2

69

138

... More
code483 - Laying of GI Pipe

3

93

279

... More
code484 - Laying of Route and Joint indicating stones

10

116

1160

... More
code485 - Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineerin- charge. (Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade) Vol-II, Page No.65, It No.11.58

45

883

39737.25

... More
code486 - DIESEL GENERATOR SETS : Supplying, installing, testing and commissioning of Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514/ISO 3046/ ISO 8528 & IS 1002/ISO 3046 Generator set specifications. Engine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade), Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation Alternator: Alternator is suitable for operation at 1500 RPM, 415 V, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming to IS/IEC 60034-1. The Alternator is brush less type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have 1.0% Voltage regulation (max) in static conditions- IP: 23 protections with insulation class F&H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lA for 'Load On' and 'Set Running', Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight, Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,-Auto start mode accepts a ground signal from remote devices to automatically start the DG set The remote start will has the following features: Specially designed to meet stringent MOEF/CPCB norms of 75dBA @ 1 m at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at rated load made on special purpose CNC machines for consistency in quality and workmanship, Powder coated for long lasting service life and superior finish, With UV resistant powder coating, can meets exacting IS 8183 specifications for better sound attenuation, NEC, NBC 2016, IEC, CPWD specifications, PCB norms and KSGEI Acts and Rules.62.5 kVA/50kW.(SR-Pg No..It-10.1.7)

1

641071

641071

... More
code487 - Supply, Erection, testing and commissioning of AMF panel suitable for .....kVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .....A 4 pole contactor for alternator with thermal O/L relay,..... A 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, ....capacity bypass switch and frequency sensing, PCC 1301controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ kVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AM module by pass Mode, Battery charger unit with inbuilt Auto/Manual and Flat/Boost facility. The complete set shall have sufficient safety and adhere to NEC, NBC 2016, IEC, CPWD specifications, PCB norms and KSGEI Acts and Rules.(SR-Pg No..It-10.2.2) . 62.5KVA to 125 KVA

1

77768

77768

... More
code488 - COMPOUND WALL: 'Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth, consider 10% of total excavation qty , Vol-I, Page No 8, Item No.1.15.1

13.77

381

5248.4355

... More
code489 - Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. IIn Hard Rock ( requiring blasting) Depth upto 1.50m 90% of total excavation qty. vol -1- Page No.9, It No.1.16.1

123.9

581

72072.63

... More
code490 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. SR 2023-24, Vol-I, Page No 7, Item No.1.9

90.36

279

25237.548

... More
code491 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. SR 2023-24, Vol-I, Page No 7, Item No.1.9

5.66

279

1580.838

... More
code492 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite / trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8 (M7.5) Using 40 mm and down size graded crushed coarse aggregates SR 2023-24, Vol-I, Page No 15, Item No.2.1.2

11.14

5947

66251.808

... More
code493 - Providing and laying in position plain cement concrete for levelling course for all works in foundation.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate ibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm and down size graded crushed coarse aggregates SR 2023-24, Vol-I, Page No 15, Item No.2.1.3

2.56

6288

16098.432

... More
code494 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SR 2023-24, Vol-I, Page No 15, Item No.2.2.3, consider 8% of finished rate of concrete for foundation upto plitnth shuttering

18.5

7185

132922.87

... More
code495 - Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/ trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SR 2023-24, Vol-I, Page No 17, Item No.2.4.3 Column Below Ground Level

2.66

11309

30083.9616

... More
code496 - Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/ trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SR 2023-24, Vol-I, Page No 17, Item No.2.4.3 Plinth Beam

11.78

9979

117554.976

... More
code497 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SR 2023-24, Vol-I, Page No 17, Item No.2.5.2 Entrance Gate Steps, consider 70% of finished rate of concrete for column shuttering upto 5m

2.61

12214

31880.5236

... More
code498 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SR 2023-24, Vol-I, Page No 17, Item No.2.5.2 Retaing Wall

15.68

12214

191527.4368

... More
code499 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SR 2023-24, Vol-I, Page No 17, Item No.2.5.2 Roof Beam

4.23

12358

52276.2858

... More
code500 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SR 2023-24, Vol-I, Page No 17, Item No.2.5.2, consider 60% of finished rate of concrete for beam shuttering Lintel Concrete

0.23

11496

2644.1352

... More
code501 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SR 2023-24, Vol-I, Page No 17, Item No.2.5.2 Chejja Concrete

0.29

10418

3021.3563

... More
code502 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SR 2023-24, Vol-I, Page No 17, Item No.2.5.2, Roof Slab

1.66

10777

17891.0318

... More
code503 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification SR 2023-24, Vol-I, Page No 18, Item No.2.11 a

6.08

93929

571093.488

... More
code504 - Providing and fixing concertina coil fencing with punched tape concertina coil 600mm dia 10 m openable length ( total length 90 m), having 50 nos rounds per 6 m length, upto 3 m height of wall with existing angleiron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/mm2 with tape (0.52 mm thick) and weight 43.478 g/m (cost of M.S. angle, C.C. blocks shall be paid separately) SR 2023-24, Vol-II, Page No 92, Item No.11.61

110

331

36498

... More
code505 - Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineerin- charge. (Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade), Remaining 2 side Compound wall fencing, Vol-II, Page No.65, It No.11.58

390

883

344389.5

... More
code506 - Fencing with G.I. barbed wire Angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. With G.I. barbed wire. (Vol-II, Page No.95, It No.11.57)

780

18

14742

... More
code507 - Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete. (Vol-II, Page No.95, It No.11.57.2)

1125

118

133481.25

... More
code508 - Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) SR 2023-24, Vol-II, Page No 9, Item No.5.4

5.67

6708

38036.9115

... More
code509 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. SR 2023-24, Vol-II, Page No 17, Item No.6.33

33.33

1292

43080.6915

... More
code510 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. SR 2023-24, Vol-II, Page No 17, Item No.6.32

210

1375

288855

... More
code511 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. SR 2023-24, Vol-II, Page No 17, Item No.6.34

5.52

1159

6398.784

... More
code512 - Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Inside walls) SR 2023-24, Vol-II, Page No 42, Item No.8.7

42.66

384

16394.238

... More
code513 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.External SR 2023-24, Vol-II, Page No 42, Item No.8.8

455.52

389

177447.816

... More
code514 - Providing and fixing factory made single extruded WPC (Wood PolymerComposite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (SuspensionGrade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for100 g) fabricated with miter joints after applying PVC solvent cement andscrewed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) &1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus ofelasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fireretardant and fixed in position with M.S hold fast/lugs/SS dash fastenersof required dia and length complete as per direction of Engineer-InCharge.(Fixtures shall be paid for separately) SR 2023-24, Vol-II, Page No 111 , Item No.12.93.1

10.8

737

7960.68

... More
code515 - Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness SR 2023-24, Vol-II, Page No 112 , Item No.12.94.1

1.8

3659

6586.65

... More
code516 - Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) SR 2023-24, Vol-II, Page No 112 , Item No.12.89

4.32

6878

29715.336

... More
code517 - Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE (Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) SR 2023-24, Vol-II, Page No 109 , Item No.12.85

0.48

6004

2882.376

... More
code518 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. SR 2023-24, Vol-II, Page No. 86 , Item No.11.34A

100.8

176

17781.12

... More
code519 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. SR 2023-24, Vol-II, Page No. 50 , Item No.8.51

52.09

105

5469.45

... More
code520 - Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SR 2023-24, Vol-II, Page No. 46 , Item No.8.33.1

52.09

165

8641.731

... More
code521 - Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SR 2023-24, Vol-II, Page No. 46 , Item No.8.31

455.52

186

85136.688

... More
code522 - Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. SR 2023-24, Vol-II, Page No. 61 , Item No.9.17.2

10.54

1233

13003.725

... More
code523 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. SR 2023-24, Vol-II, Page No. 60 , Item No.9.11

2.16

933

2016.252

... More
code524 - Providing and fixing 1 mm thick M.S. sheet sliding-shutters, with frame and diagonal braces of 40x40x6 mm angle iron, 3 mm M.S. gusset plates at the junctions and corners, 25 mm dia pulley, 40x40x6 mm angle and T- iron guide at the top and bottom respectively, including applying a priming coat of approved steel primer including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. SR 2023-24, Vol-II, Page No. 75 , Item No.11.4

24.8

5482

135954.84

... More
code525 - Providing and fixing RCC precast fencing pole of size 0.15mx0.15mx2.0m casted in M 20 with 20mm down size aggregates making holes for drawing barbed wire at 30 cm c/c using 8 mm dia vertical 4 TMT steel rods and 6 mm dia stirups at 15 cm c/c fixed 1.5 m above Ground level using steel moulding , curing , transportation to work spot including excavation in all types of soil, fixing in plain cement concrete M15 using 20 mm downsize aggregate including aligning to plumb and line providing including cost of all materials, labour,usage charges of machinery complete. (Vol -II- Page no.96)

74.29

1139

84634.8825

... More
code526 - PAVEMENT AND LANDSCAPE: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.Cement concrete paver block. vol 3-Page No. 9, 2.5-ii a

4.5

412

1856.925

... More
code527 - Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work. vol 3-17, It No.301

90

89

8032.5

... More
code528 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap /basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8 (M7.5) Using 40 mm and down size graded crushed coarse aggregates. (vol -1 - Page No.15, It No 2.1.2)

3

5947

17841.6

... More
code529 - Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) (vol -3 - Page No.74, It No 8.4.2)

100

262

26250

... More
code530 - Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces. (vol -3 - Page No.66, It No 803)

50

110

5512.5

... More
code531 - Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, griding the edge to half/full round wherever required, labour, curing complete as per specification. vol -2, It No. 9.4

425

978

415905

... More
code532 - Parking Area: ''Clearing and grubbing road, land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.-By Mechanical Means using Dozer-In area of thorny jungle

71.5

508

36336.3

... More
code533 - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. vol -1- 8, It No.1.14.1

13.63

381

5195.0745

... More
code534 - Earth work excavation by manual means for drains,canals, waste weir,draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading,caution lights, removal of stumps and other deleterious matter,excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m. vol -1- Page No.5, It No.1.14.1

1.96

254

498.036

... More
code535 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates- vol -1 -Page No- 15, It No.2.1.6

17.99

6555

117927.1485

... More
code536 - Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge..vol -II- Page No.82,It No. 11.16.2

1448.57

154

223586.7795

... More
code537 - Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge. 0.63 mm thick with zinc coating not less than 275 g/ m². vol -II- Page No.21, It No.7.1.1

80

922

73836

... More
code538 - Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, griding the edge to half/full round wherever required, labour, curing complete as per specification. vol -II- Page No.65, It No.9.40

80

978

78288

... More
code539 - ARCHITECTURAL FEATURES : Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge.all-round

250

72

18000

... More
code540 - Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.

1800

52

93600

... More
code541 - MOULDING : Providing 200 mm height architectural moulding with three stepswith 50mm on top and bottom and 100 mm middle champhered steps in standard architectural methods of execution running on thre edge of the slab, canopy and other places as shown in the drawings or as per the instructions given. the rate includes, materials, labour and complete.

250

1800

450000

... More
code542 - INTERIOR: Providing and fixing Free Standing Table for Cabin - without frames consisting of 25 mm thick PLPB table top, 25 mm thick PLPB with edge bomded End table, 18 mm thick PLPB with edge bonded Modesty, Wire manager - ABS plastic grommet one number per table table Hardware-Minifix assembly and screw leg, as per specifications, drawings and as directed by Engineer in charge. Main Table : 1500 mmW x 750mm D x 750 mm ht (Edgebinding table top) Side Table : 900 mm W x 450 mm D x 750 mm ht. It No 39.17.1

6

12558

75348

... More
code543 - Providing and fixing Free Standing Table for Cabin - without frames consisting of 25 mm thick PLPB table top, 25 mm thick PLPB with edge bomded End table, 18 mm thick PLPB with edge bonded Modesty, Wire manager - ABS Plastic grommet one number per table Hardware-Minifix assembly and screw leg., as per specifications, drawings and as directed by Engineer in charge. Table : 1200mm x 600 mm x 750mm ht (Main table with Post formed table top)

10

7360

73605

... More
code544 - Providing and fixing CUBICLE WORKSTATIONS consisting of wings made out of 75 mm thick MS CRCA powder coated, tile based system for main and return spine, Top tile finish 8 mm thick MDF covered with fabric of approved colour and one writing board (600 mm W) and one soft board (600 mm W) per workstation, Bottom tile finish 9 mm thick Laminate tile of approved colour, Raceway-one middle raceway (600mm W) below table top per workstation and continuous raceway at the skirting level, Wire manager -ABS plastic grommet one number per table, Table top - 25 mm thick PLPB with straight table top End Table 25 mm thick PLPB with straightedge bound Hardware -MS powder coated corner bkt, cantilever bkt, separator hook on bkt, L bkt and Table joint plate., as per specifications, drawings and as directed by Engineer in charge x type 4 wings -3A) size 1500 mmW x 1200mm D x 1200 mm ht .

5

52500

262500

... More
code545 - Providing and fixing CUBICLE WORKSTATIONS consisting of wings made out of 75 mm thick MS CRCA powder coated, tile based system for main and return spine, Top tile finish 8 mm thick MDF covered with fabric of approved colour and one writing board (600 mm W) and one soft board (600 mm W) per workstation, Bottom tile finish 9 mm thick Laminate tile of approved colour, Raceway-one middle raceway (600mm W) below table top per workstation and continuous raceway at the skirting level, Wire manager -ABS plastic grommet one number per table, Table top - 25 mm thick PLPB with straight table top End Table 25 mm thick PLPB with straightedge bound Hardware -MS powder coated corner bkt, cantilever bkt, separator hook on bkt, L bkt and Table joint plate., as per specifications, drawings and as directed by Engineer in charge. T Type 2 wings 3C) Size : 1500 mmW x 1200mm D x 1200 mm ht

5

33600

168000

... More
code546 - Providing and fixing discussion table metal leg consisting of 25 mm thick PLPB table top edge bounded MS CRCA sheet round plate at bottom and 75 mm dia pole at centre with 25 x 25 tube welded at top Hardware-L bkt and screw leg., as per specifications, drawings and as directed by iengineer in charge. 750 mm Dia x 750 mm Ht

3

9366

28098

... More
code547 - Meeting Table: Providing and fixing meeting table consisting of 25mm thick PLPB table top edge bounded, 25mm thick PLPB with edge bonded End table , 18mm thick PLPB with edge bonded Modesty, Hardware-Minifix assembly and screw leg., as per specifications, drawings and as directed by Engineer in charge.1500mm Dia X 900mm D X 750mm Ht (6 seater)

1

12652

12652.5

... More
code548 - Conference Table: Providing and fixing conference table consisting of 25 mm thick PLPB table top edge bounded, 25 mm thick PLPB with edge bonded End table, 18 mm thick PLPB with edge bonded Modesty, Hardware-Minifix assembly and screw leg, as per specifications, drawings and as directed by Engineer in charge. 4800mmX2400mmX750mm ht (20 seater)- U shaped with top width of 600mm

1

66990

66990

... More
code549 - Modular Partition: Providing and fixing modular partition consisting of 75mm thick MS CRCA frames powder coated, tile based system frame, 8mm thick MDF covered with Fabric of approved colour for Top file finish, 5mm thick clear ordinary glass both side Middle tile finish, or 8mm thick MDF covered with Fabric of approved colour for Middle tile finish , 9mm thick Laminate tile of approved colour for Bottom tile finish, Continuos Skirting level raceway will be provided. as per specifications, drawings and as directed by Enginner in charge. 75mm thick frames tile based system (Frame with tile)

48

5040

241920

... More
code550 - Providing and fixing wood storage unit one side laminate with 18 mm PLY/PLPB edge bound for body, 18mm PLY/PLPB with openable shutters and individual locking system for shutter, 9 mm PLY with edge bound for rear portion with Hafele fitting hingers, Hafele locks, Minifix assembly, screw legs, Handles and tower bolt, complete as per specifications, drawings and as directed by Engineer in charge. PLPB STORAGE-900 mm W x 430 mm D x 750 mm

5

7171

35857.5

... More
code551 - Providing and fixing wood storage unit one side laminate with 18 mm PLY/PLPB edge bound for body, 18mm PLY/PLPB with openable shutters and individual locking system for shutter, 9 mm PLY with edge bound for rear portion with Hafele fitting hingers, Hafele locks, Minifix assembly, screw legs, Handles and tower bolt, complete as per specifications, drawings and as directed by Engineer in charge.PLPB STORAGE - 900 mm Wx 430 mmD x 1200mm Ht

8

10311

82488

... More
code552 - Providing and fixing wood storage unit one side laminate with 18 mm PLY/PLPB edge bound for body, 18mm PLY/PLPB with openable shutters and individual locking system for shutter, 9 mm PLY with edge bound for rear portion with Hafele fitting hingers, Hafele locks, Minifix assembly, screw legs, Handles and tower bolt, complete as per specifications, drawings and as directed by Engineer in charge.PLPB STORAGE-900 mm W x 430 mm D x2100 mm

6

17808

106848

... More
code553 - Providing and fixing 450mmw x 450 mmd x 685 mmht) Mobile pedestal unit-WOODEN with 18mm thick PLPB with edge bonded for body, Two equal drawer and filing drawer with centralized locking system, Telescopic channels, castors, Handles and lock, etc., complete as per specifications, drawings and as directed by Engineer in charge.

8

5145

41160

... More
code554 - Providing & fixing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame.

56.6

1393

78863.61

... More
code555 - Providing & Fixing of Mineral Fibre Suspended Ceiling System in the module size of 600x600x19mm with Exposed grid for Hospitals,Shopping malls, Commercial establishments and office complexes. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance 87%, Thermal Conductivity k = 0.052 - 0.057 w/m K, NRC -0.7,Colour White, Fire Performance UK A2 S1, dO, with Anti Microbial coating on the face of the tile, suitable for zone 4 area according to NF S 90-35:2003 with cleanroom class of ISO 5 (Class 100), Decontamination Class of CP1Oand Bacteriological Cleanliness Class B1 for specific strains and reduction in colony size. Washability properties of 500 wash cycles as per ASTM D-4828 and suitable for Green Building application with Recycled content of 37%. The tile shall be laid on 24mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm and a load carrying capacity of 15 kg/m2 & pull out strength of minimum 100 kg The T Sections should have a Galvanizing of 90 grams per m2 and need to be installed with suspension system of approved make. Court hall

72.5

2608

189094.5

... More
code556 - Providing and supplying 'Acoustical Wall Paneling' with square edges made of fibre glass substrate 25mm thick and wrapped on the front side with an acoustically transparent and classified for Fire reaction Class A, as per ASTM E-84, fabric with option of colors - as per the choice of the Architect/Engineer incharge of the size 600x600mm, 600x1200mm & 600x1800mm providing a minimum sound absorption level of 0.85 NRC to be affixed to wall using Wall panel lmpaler sand construction adhesives as per the instructions laid down by the certified manufacturer.

132.91

3071

408199.8375

... More
code557 - Providing and fixing storage unit of 0.75m width made out of 19mm thick commercial ply vertical support finished in approved 1.5mm laminate with 12mm thick ply packing internally finished with enamel paint of approved colour and shade shelves shall be formed out of 19mm ply finished with enamel paint of approved shade and colour and 19mm thick shutters formed out of 19mm thick ply finished with 1.5mm thick laminate of approved shade and colour etc., complete the rate includes cost of all materials, labour charges, complete as per specification.

23.52

13723

322776.72

... More
code558 - Providing & fixing Vertical Blinds of reputed make of shape 100mm regular fabric with powder coated aluminium channel, telting with PVC Chain system with all necessary fittings and fixtures as per direction of Engineer in charge

15.12

892

13494.6

... More
code559 - Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.

67.7

3655

247446.885

... More
code560 - Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc. to be paid separately) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.

9.6

6437

61800.48

... More
code561 - Table : Providing and fixing Executive tables of different sizes with 19 mm waterproof plywood frame work laminated on all the exposed surface with 1 mm thick laminate and a key board tray is provided and all edges of the plywood is lipped with 19mm x 6mm teak/beach wood lipping and the edge of the table top is lipped with 32 mm x 19 mm teak/beach wood lipping. The item to include a side cabinet with 19 mm thick waterproof plywood framework, shelves and shutters laminated on all the exposed surface with 1mm thick laminate and inside surface is also laminate with 0.8 mm laminate. The item to include all hardware like stainless steel hinges, drawer sliders, Euro multipurpose locks, brush steel handles, magnetic catch, all hardware complete and all the teak/beach wood beading is polished.

3

64464

193392

... More
code562 - Providing and supplying sofa using silver wood frame work with Arm rest on both sides using 4" foam &2" foam of Restole on equivalant, and 2"& 1" foam similar to ufoam on equivalent, with leatharite upholsrory, 4 caster SS wheels as shown in figure.

160

2150

344000

... More
code563 - DOUBLE SEATER SOFA: Providing & fabricating DOUBLE SEATER SOFA in silver wood frame work with 150mm thick foam backing for seat & back rest clad with two layers of 12mm thick foam of approved make clad with 2mm thick foam finished in approved leatherette. The sofa to be provided with 50mm ht. SS legs complete as per detail dwg & instructions of the Engineer-in-charge.

2

26861

53722

... More
code564 - HIGH BACK CHAIR- FABRIC with castors Supplying & placing in position High back chair with following specification. Seat: Seat to be formed out of bent ply / PVC backing with deformable pre moulded foam upholstered with approved fabric. Back rest: The High back rest in fabric over frame. The back rest to have provision of height adjustable backrest for an optimum adjustment of the lumbar support, to be either by turning knob or push- button. upholstered with Mesh fabric. Mechanism: Synchronised knee-tilt with 2 way locking mechanism. Gas lift: synchronised gas lift. Arm rest: Adjustable arm rest to be formed out of PU foam / PVC with provision of height swinging adjustment, Width adjustment, height adjustments. Base: Base shall consist of 5 prong formed of die cast aluminium with chrome plated finish with soft-dual wheel casters. Castors: Twin wheel high resistant polyamide castors.

8

8637

69096

... More
code565 - OFFICERS CHAIRS : Supplying HIGH BACK Chair of M/s Godrej M/s.Featherlite of M/s Eurotech, M/s. Blue mango with contact crome flex back chair with co-active synchro, gas lift, revolving, tilting, and height adjustable fully cushioned medium back chairs and two way adjustable arms. prior confirmation shall be obtain from the officer / Architect for approval.

8

6330

50640

... More
code566 - STAFF CHAIRS : Supplying MEDIUM BACK Chair of M/s Godrej M/s.Featherlite of M/s Eurotech, M/s. Blue mango with contact crome flex back chair with co-active synchro, gas lift, revolving, tilting, and height adjustable fully cushioned medium back chairs and two way adjustable arms. prior confirmation shall be obtain from the officer / Architect for approval

60

4000

240000

... More
code567 - PROVIDING ALL SAFE OFFICE LOCKER STEEL ALMIRAH (900X1800X600).depth with 5 shelves of 14 gauge powder coated the rate including one locker

5

12840

64200

... More
code568 - 3 seater sofa with stainless steel finsh as per approved model

7

10620

74340

... More
code569 - Providing, Supplying and fixing Godrej Plus Strong Room Door of Size 1.32x.525x2.33m as required

1

295000

295000

... More
code570 - CC ROAD : Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (vol 3-Page No.9, It No.2.5-ii a)

15

412

6189.75

... More
code571 - Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work. (vol 3-17, It No.301)

225

89

20081.25

... More
code572 - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth, consider 5% of total excavation qty. vol -1- Page No 8. It No.1.14.1

22.5

381

8575.875

... More
code573 - Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. In Hard Rock (Required Blasting) depth exceeding 1.5m but not exceeding 3 mconsider 95% of total excavation qty vol -1- Page No.9, It No.1.16.1

427.5

581

248676.75

... More
code574 - Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.vol 1-Page No.7, It No.1.8

900

497

447930

... More
code575 - Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2. vol 3-Page No.17, It No.305

112.5

517

58235.625

... More
code576 - Construction of Dry lean cement concrete sub-base over a prepared sub grade with coarse and fine aggregates confirming to IS 383:2016 the size of coarse aggregates not exceeding 25mm replacing cement by fly ash to the extent of 20 percent, aggregate cement ratio not to exceed 12:1 aggregates gradation after blending to be as per table 600-1, cement & cementitious content not to be less than 140 kg/m3, optimum moisture content to beg.determined during trial length construction , concrete strength not to be less than 7 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing.vol 3-Page No 49 IRC-SP49-2014

60

4971

298305

... More
code577 - Construction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing. vol 3-Page No.49, It No6.2.1

87.75

9514

834857.8875

... More
code578 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. vol -I- Page No.18 It No.2.11 (a)

0.7

93929

65750.895

... More
code579 - CC CULVERT : Earth work excavation for pipeline trenches in all kinds of by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm whevere necessary as directed, removal of slumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata.Considering 100% of the qnty for ordinary soil vol-I-Page No.10, It No.1.17.1

14.83

275

4079.733

... More
code580 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/ trap /basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm and down size graded crushed coarse aggregates. vol -1 - Page No.15, It No.2.1.3

1.06

6288

6665.757

... More
code581 - Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. vol -1 - Page No.17, It No.2.4.2

4.74

6639

31469.571

... More
code582 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (Vol -I- Page No. 18, It No.2.11(b))

0.7

94510

66157.35

... More
code583 - Flag Pole : Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m-Page No. 8 Sl. No.1.14-VOL-1

7.14

107

764.694

... More
code584 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Sl.No 2.1.3, Page No.15-VOL-1

1.79

6288

11256.3255

... More
code585 - Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)- Sl.no-5.4, page no-9,volume-2.

6.12

6708

41055.714

... More
code586 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates- Page 15, Sl. No.2.1.6, Volume-I

0.68

6555

4457.502

... More
code587 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.- SL.No 1.9, Page No.7, VOL-1

3.09

279

863.037

... More
code588 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No. 8.2.1, Page No.41, Volume- 2.

11.88

309

3679.83

... More
code589 - Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 (1 cement : 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete. Sl.No 10.18, Page No.71 Volume-II

13.72

3526

48389.754

... More
code590 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sl.No 11.28, Page No.85, Volume-2.

35

593

20763.75



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.