Karnataka Housing Board Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Karnataka Housing Board - KHB Tender

Works
Civil And Construction
Building Construction
Opening Date23 Oct 2024
Closing Soon6 Nov 2024
Tender Amount₹ 6,72,61,320.46 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.(P.No.5, I.No 4.1 (Vol-2) of PW, P&IWTD SR 2023-24) Plinth Area

618.6

121

75184.644

... More
code05 - PCC Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8 (M7.5) Using 40 mm nominal size graded crushed coarse aggregates (P.No.5, I.No 2.1.2 (Vol-1) of PW, P&IWTD SR 2023-24) Footing

118.9815

5833

694128.55248

... More
code06 - CONCRETE FOR FOOTING Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.15, I.No 2.2.3 (Vol-1) of PW, P&IWTD SR 2023-24)

243.95

6526

1592037.216

... More
code07 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.15, I.No 2.2.3 (Vol-1) of PW, P&IWTD SR 2023-24) Shuttering - 8%

19.52

6526

127389.0816

... More
code08 - CONCRETE BELOW GROUND LVL Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.15, I.No 2.2.3 (Vol-1) of PW, P&IWTD SR 2023-24) Column casting upto plinth

9.94

6526

64869.2352

... More
code09 - CONCRETE BELOW GROUND LVL Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.15, I.No 2.2.3 (Vol-1) of PW, P&IWTD SR 2023-24) Column casting upto plinth Column shuttering-70%

6.96

6526

45421.5168

... More
code10 - Columns Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No 2.5.2 (Vol-1) of PW, P&IWTD SR 2023-24) Ground floor

34.78

7048

245139.5262

... More
code11 - Columns Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No 2.5.2 (Vol-1) of PW, P&IWTD SR 2023-24) Ground floor Column shuttering-70%

24.34

7048

171555.3786

... More
code12 - Columns Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No 2.5.2 (Vol-1) of PW, P&IWTD SR 2023-24) First floor

29.59

7118

210644.4043

... More
code13 - Columns Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No 2.5.2 (Vol-1) of PW, P&IWTD SR 2023-24) First floor Column shuttering-70%

20.71

7118

147429.7267

... More
code14 - Columns Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No 2.5.2 (Vol-1) of PW, P&IWTD SR 2023-24) Second Floor

29.59

7189

212730.2034

... More
code15 - Columns Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No 2.5.2 (Vol-1) of PW, P&IWTD SR 2023-24) Second Floor Column shuttering-70%

20.71

7189

148889.5746

... More
code16 - Columns Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No 2.5.2 (Vol-1) of PW, P&IWTD SR 2023-24) Third floor

29.59

7259

214815.7066

... More
code17 - Columns Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No 2.5.2 (Vol-1) of PW, P&IWTD SR 2023-24) Third floor Column shuttering-70%

20.71

7259

150349.2154

... More
code18 - Columns Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No 2.5.2 (Vol-1) of PW, P&IWTD SR 2023-24) Fourth floor

29.59

7330

216901.2098

... More
code19 - Columns Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No 2.5.2 (Vol-1) of PW, P&IWTD SR 2023-24) Fourth floor Column shuttering-70%

20.71

7330

151808.8562

... More
code20 - Columns Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No 2.5.2 (Vol-1) of PW, P&IWTD SR 2023-24) Head room and lift

3.24

7400

23978.268

... More
code21 - Columns Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No 2.5.2 (Vol-1) of PW, P&IWTD SR 2023-24) Head room and lift Column shuttering-70%

2.27

7400

16799.589

... More
code22 - LIFT CONCRETE Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No 2.5.2 (Vol-1) of PW, P&IWTD SR 2023-24)

3.7

7048

26078.673

... More
code23 - LIFT CONCRETE Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No 2.5.2 (Vol-1) of PW, P&IWTD SR 2023-24) shuttering-10%

0.37

7048

2607.8673

... More
code24 - Curtain wall Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1)Bed Concrete

24.71

7048

174163.2459

... More
code25 - Curtain wall Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1)Bed Concrete shuttering-8%

2.47

7048

17409.2763

... More
code26 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) plinth beam

27.52

7048

193968.9408

... More
code27 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) plinth beam Plinth Beam shuttering-50%

13.76

7048

96984.4704

... More
code28 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Roof beam Ground floor

47.43

7048

334300.3947

... More
code29 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Roof beam Ground floor Beam shuttering-60%

28.46

7048

200594.3334

... More
code30 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Roof beam First floor

47.45

7118

337785.6365

... More
code31 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Roof beam First floor Beam shuttering-60%

28.47

7118

202671.3819

... More
code32 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Roof beam Second floor

47.45

7189

341130.387

... More
code33 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Roof beam Second floor Beam shuttering-60%

28.47

7189

204678.2322

... More
code34 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Roof beam Third floor

47.45

7259

344474.663

... More
code35 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Roof beam Third floor Beam shuttering-60%

28.47

7259

206684.7978

... More
code36 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Roof beam Fourth floor

47.45

7330

347818.939

... More
code37 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Roof beam Fourth floor Beam shuttering-60%

28.47

7330

208691.3634

... More
code38 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Roof beam Head room

1.51

7400

11175.057

... More
code39 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Roof beam Beam shuttering-60%

0.91

7400

6734.637

... More
code40 - Slab Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Ground floor

100.51

7048

708423.6279

... More
code41 - Slab Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Ground floor Slab shuttering-50%

50.26

7048

354247.0554

... More
code42 - Slab Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) First floor

92.38

7118

657631.9726

... More
code43 - Slab Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) First floor Slab shuttering-50%

46.19

7118

328815.9863

... More
code44 - Slab Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Second floor

92.38

7189

664143.8388

... More
code45 - Slab Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Second floor Slab shuttering-50%

46.19

7189

332071.9194

... More
code46 - Slab Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Third floor

92.38

7259

670654.7812

... More
code47 - Slab Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Third floor Slab shuttering-50%

46.19

7259

335327.3906

... More
code48 - Slab Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Fourth floor

92.38

7330

677165.7236

... More
code49 - Slab Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Fourth floor Slab shuttering-50%

46.19

7330

338582.8618

... More
code50 - Slab Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Head room& lift slab

5.93

7400

43886.151

... More
code51 - Slab Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Head room& lift slab Slab shuttering-50%

2.97

7400

21980.079

... More
code52 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) For Chejjas Ground floor

2.5

7048

17620.725

... More
code53 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) For Chejjas Ground floor Shuttering 45%

1.13

7048

7964.5677

... More
code54 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) For Chejjas First Floor

2.27

7118

16159.6079

... More
code55 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) For Chejjas First Floor shuttering-45%

1.02

7118

7261.1454

... More
code56 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) For Chejjas second floor

2.27

7189

16319.6202

... More
code57 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) For Chejjas second floor shuttering-45%

1.02

7189

7333.0452

... More
code58 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) For Chejjas Third floor

2.27

7259

16479.6098

... More
code59 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) For Chejjas Third floor shuttering-45%

1.02

7259

7404.9348

... More
code60 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) For Chejjas fourth floor

2.27

7330

16639.5994

... More
code61 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) For Chejjas fourth floor shuttering-45%

1.02

7330

7476.8244

... More
code62 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) For Chejjas terrace floor

0.2

7400

1480.14

... More
code63 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) For Chejjas terrace floor shuttering-45%

0.09

7400

666.063

... More
code64 - THROUGH LINTEL Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) ground floor

22.94

7048

161687.7726

... More
code65 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) ground floor shuttering 60%

13.76

7048

96984.4704

... More
code66 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) First floor

25.12

7118

178823.5024

... More
code67 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) First floor shuttering-60%

15.07

7118

107279.8639

... More
code68 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Second floor

25.12

7189

180594.2112

... More
code69 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Second floor shuttering-60%

15.07

7189

108342.1482

... More
code70 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Third floor

25.12

7259

182364.6688

... More
code71 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Third floor shuttering-60%

15.07

7259

109404.2818

... More
code72 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Fourth floor

25.12

7330

184135.1264

... More
code73 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Fourth floor shuttering-60%

15.07

7330

110466.4154

... More
code74 - THROUGH Cill Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) ground floor

9.17

7048

64632.8193

... More
code75 - THROUGH Cill Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) ground floor shuttering-60%

5.5

7048

38765.595

... More
code76 - THROUGH Cill Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) First floor

10.05

7118

71543.6385

... More
code77 - THROUGH Cill Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) First floor shuttering-60%

6.03

7118

42926.1831

... More
code78 - THROUGH Cill Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Second floor

10.05

7189

72252.063

... More
code79 - THROUGH Cill Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Second floor shuttering-60%

6.03

7189

43351.2378

... More
code80 - THROUGH Cill Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Third floor

10.05

7259

72960.387

... More
code81 - THROUGH Cill Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Third floor shuttering-60%

6.03

7259

43776.2322

... More
code82 - THROUGH Cill Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Fourth floor

10.05

7330

73668.711

... More
code83 - THROUGH Cill Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Fourth floor shuttering-60%

6.03

7330

44201.2266

... More
code84 - Staircase Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Ground floor

4.88

7048

34395.6552

... More
code85 - Staircase Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Ground floor shuttering-50%

2.44

7048

17197.8276

... More
code86 - Staircase Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) First floor

4.88

7118

34739.5976

... More
code87 - Staircase Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) First floor shuttering-50%

2.44

7118

17369.7988

... More
code88 - Staircase Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Second floor

4.88

7189

35083.5888

... More
code89 - Staircase Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Second floor shuttering-50%

2.44

7189

17541.7944

... More
code90 - Staircase Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Third floor

4.88

7259

35427.5312

... More
code91 - Staircase Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Third floor shuttering-50%

2.44

7259

17713.7656

... More
code92 - Staircase Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Fourth floor

4.88

7330

35771.4736

... More
code93 - Staircase Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.5.2 of PW, P&IWTD SR 2023-24)(vol-1) Fourth floor shuttering-50%

2.44

7330

17885.7368

... More
code94 - Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates (P.No.16, I.No.2.4.1 of PW, P&IWTD SR 2023-24)(vol-1) (P.No.16, I.No 2.4.4 (Vol-1) of PW, P&IWTD SR 2023-24) flaging Concrete

5.58

6596

36806.3496

... More
code95 - Footing & pedestal Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24)

19515.84

92

1798189.4976

... More
code96 - Column Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24)

2782.08

92

256340.8512

... More
code97 - Below plinth Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24) Ground floor

9737.28

92

897192.9792

... More
code98 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24) first floor

8285.76

93

771072.8256

... More
code99 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24) Second floor

8285.76

93

778778.5824

... More
code100 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24) Third floor

8285.76

94

786484.3392

... More
code101 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24) Fourth Floor

8285.76

95

794355.8112

... More
code102 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24) Head room

907.2

96

87844.176

... More
code103 - Beams Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24) Plinth Beam

6053.49

92

557768.5686

... More
code104 - Roof beams Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24) Ground floor

10434.35

92

961421.009

... More
code105 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24) first floor

6263.28

93

582860.8368

... More
code106 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24) Second floor

6263.28

93

588685.6872

... More
code107 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24) Third floor

6263.28

94

594510.5376

... More
code108 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24) Fourth Floor

6263.28

95

600460.6536

... More
code109 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24) Head room

331.85

96

32133.0355

... More
code110 - Lintel Beams Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24) Ground Floor

2293.7

92

211341.518

... More
code111 - Lintel Beams Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24) First floor

2511.81

93

233749.0386

... More
code112 - Lintel Beams Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24) Second floor

159

93

14944.41

... More
code113 - Lintel Beams Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24) Third floor

159

94

15092.28

... More
code114 - Lintel Beams Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24) Fourth Floor

159

95

15243.33

... More
code115 - Lintel Beams Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24) Head room

37

96

3582.71

... More
code116 - Slab Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24) Ground floor

8041.18

92

740914.3252

... More
code117 - Slab Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24) First floor

7390.04

93

687717.1224

... More
code118 - Slab Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24) Second floor

7390.04

93

694589.8596

... More
code119 - Slab Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24) Third floor

7390.04

94

701462.5968

... More
code120 - Slab Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24) Fourth Floor

7390.04

95

708483.1348

... More
code121 - Slab Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24) Head room

474.54

96

45949.7082

... More
code122 - Stair Case Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24) Ground floor

731.4

92

67391.196

... More
code123 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24) First floor

731.4

93

68064.084

... More
code124 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24) Second floor

365.7

93

34372.143

... More
code125 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24) Third floor

365.7

94

34712.244

... More
code126 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24) Fourth Floor

365.7

95

35059.659

... More
code127 - Lift concrete wall Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24) Ground floor

481.14

92

44332.2396

... More
code128 - Curtain wall Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24)

2668.72

92

245895.8608

... More
code129 - Chejja Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24) Ground floor

125.1

92

11526.714

... More
code130 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24) First floor

113.63

93

10574.4078

... More
code131 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24) Second floor

292.04

93

27448.8396

... More
code132 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24) Third floor

292.04

94

27720.4368

... More
code133 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24) Fourth Floor

292.04

95

27997.8748

... More
code134 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft cannealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings. (P.No.18, I.No 2.11 (Vol-1) of PW, P&IWTD SR 2023-24) terrace

9.9

96

959.31

... More
code135 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (P.No.7, I.No.1.9 of PW, P&IWTD SR 2023-24)(vol-1) upto plinth Column and Lift

378.93

273

103819.2414

... More
code136 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (P.No.7, I.No.1.9 of PW, P&IWTD SR 2023-24)(vol-1) earthfilling of the plinth area and column

324

273

88769.52

... More
code137 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (P.No.17, I.No.6.33 of PW, P&IWTD SR 2023-24)(vol-2) 150mm wall Ground floor

650.15

1267

824344.6895

... More
code138 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (P.No.17, I.No.6.33 of PW, P&IWTD SR 2023-24)(vol-2) 150mm wall First floor

743.94

1280

952697.0034

... More
code139 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (P.No.17, I.No.6.33 of PW, P&IWTD SR 2023-24)(vol-2) 150mm wall Second floor

655.3

1293

847492.937

... More
code140 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (P.No.17, I.No.6.33 of PW, P&IWTD SR 2023-24)(vol-2) 150mm wall Third floor

655.3

1305

855802.141

... More
code141 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (P.No.17, I.No.6.33 of PW, P&IWTD SR 2023-24)(vol-2) 150mm wall Fourth Floor

655.3

1318

864111.345

... More
code142 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (P.No.17, I.No.6.33 of PW, P&IWTD SR 2023-24)(vol-2) Terrace floor

115.54

1331

153821.8682

... More
code143 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (P.No.17, I.No.6.34 of PW, P&IWTD SR 2023-24)(vol-2) 100mm wall Ground floor

296.97

1137

337690.5264

... More
code144 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (P.No.17, I.No.6.34 of PW, P&IWTD SR 2023-24)(vol-2) 100mm wall First floor

96.57

1148

110909.6793

... More
code145 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (P.No.17, I.No.6.34 of PW, P&IWTD SR 2023-24)(vol-2) 100mm wall Second floor

96.57

1159

112007.6802

... More
code146 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (P.No.17, I.No.6.34 of PW, P&IWTD SR 2023-24)(vol-2) 100mm wall Third floor

96.57

1171

113105.6811

... More
code147 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (P.No.17, I.No.6.34 of PW, P&IWTD SR 2023-24)(vol-2) 100mm wall Fourth floor

96.57

1182

114203.682

... More
code148 - Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge (P.No.43, Vol- 2 , I.No.8.10 of PW, P&IWTD SR 2023-24) Ground floor

481.29

217

104598.7557

... More
code149 - Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge (P.No.43, Vol- 2 , I.No.8.10 of PW, P&IWTD SR 2023-24) First floor

504.8

219

110803.6

... More
code150 - Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge (P.No.43, Vol- 2 , I.No.8.10 of PW, P&IWTD SR 2023-24) Second floor

504.8

221

111904.064

... More
code151 - Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge (P.No.43, Vol- 2 , I.No.8.10 of PW, P&IWTD SR 2023-24) Third floor

504.8

223

112999.48

... More
code152 - Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge (P.No.43, Vol- 2 , I.No.8.10 of PW, P&IWTD SR 2023-24) Fourth floor

504.8

226

114094.896

... More
code153 - Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge (P.No.43, Vol- 2 , I.No.8.10 of PW, P&IWTD SR 2023-24) Terrace floor

41.03

228

9363.046

... More
code154 - Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (P.No.41, Vol- 2 , I.No.8.1.2 of PW, P&IWTD SR 2023-24) Ground floor

782.32

248

194195.2936

... More
code155 - Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (P.No.41, Vol- 2 , I.No.8.1.2 of PW, P&IWTD SR 2023-24) First floor

1370.1

250

343497.771

... More
code156 - Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (P.No.41, Vol- 2 , I.No.8.1.2 of PW, P&IWTD SR 2023-24) Second floor

1370.1

253

346936.722

... More
code157 - Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (P.No.41, Vol- 2 , I.No.8.1.2 of PW, P&IWTD SR 2023-24) Third floor

1370.1

255

350403.075

... More
code158 - Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (P.No.41, Vol- 2 , I.No.8.1.2 of PW, P&IWTD SR 2023-24) Fourth floor

1370.1

258

353896.83

... More
code159 - Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (P.No.41, Vol- 2 , I.No.8.1.2 of PW, P&IWTD SR 2023-24) Terrace floor

94.15

260

24562.7935

... More
code160 - External plastering Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge (P.No.46, Vol- 2 , I.No.8.2.2 of PW, P&IWTD SR 2023-24) Ground floor

622.66

287

178933.8042

... More
code161 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge (P.No.46, Vol- 2 , I.No.8.2.2 of PW, P&IWTD SR 2023-24) First Floor

594.67

290

172597.0208

... More
code162 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge (P.No.46, Vol- 2 , I.No.8.2.2 of PW, P&IWTD SR 2023-24) Second floor

594.67

293

174321.5638

... More
code163 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge (P.No.46, Vol- 2 , I.No.8.2.2 of PW, P&IWTD SR 2023-24) Third floor

594.67

296

176063.9469

... More
code164 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge (P.No.46, Vol- 2 , I.No.8.2.2 of PW, P&IWTD SR 2023-24) Fourth floor

594.67

299

177824.1701

... More
code165 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge (P.No.46, Vol- 2 , I.No.8.2.2 of PW, P&IWTD SR 2023-24) Head room Parapet wall

356.41

302

107642.9482

... More
code166 - Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm (P.No.60, Vol- 2 , I.No.9.12.2 of PW, P&IWTD SR 2023-24) Ground floor

345.93

1179

407972.5455

... More
code167 - Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm (P.No.60, Vol- 2 , I.No.9.12.2 of PW, P&IWTD SR 2023-24) First floor

310.7

1191

370087.198

... More
code168 - Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm (P.No.60, Vol- 2 , I.No.9.12.2 of PW, P&IWTD SR 2023-24) Second floor

310.7

1203

373787.635

... More
code169 - Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm (P.No.60, Vol- 2 , I.No.9.12.2 of PW, P&IWTD SR 2023-24) Third floor

310.7

1215

377528.463

... More
code170 - Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm (P.No.60, Vol- 2 , I.No.9.12.2 of PW, P&IWTD SR 2023-24) Fourth floor

310.7

1227

381306.575

... More
code171 - Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directedby the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent. (P.No.63, Vol- 2 , I.No.9.23 of PW, P&IWTD SR 2023-24) ground floor

38.48

2539

97738.4304

... More
code172 - Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge (P.No.64, I.No.9.31 of PW, P&IWTD SR 2023-24)(vol-2) Ground floor

160.01

2147

343629.4755

... More
code173 - Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge (P.No.64, I.No.9.31 of PW, P&IWTD SR 2023-24)(vol-2) First floor

130.95

2169

284034.4785

... More
code174 - Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge (P.No.64, I.No.9.31 of PW, P&IWTD SR 2023-24)(vol-2) Second floor

130.95

2190

286873.4745

... More
code175 - Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge (P.No.64, I.No.9.31 of PW, P&IWTD SR 2023-24)(vol-2) Third floor

130.95

2212

289739.97

... More
code176 - Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge (P.No.64, I.No.9.31 of PW, P&IWTD SR 2023-24)(vol-2) Fourth floor

130.95

2234

292639.203

... More
code177 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. (P.No.60, I.No.9.11-Vol-2 of PW, P&IWTD SR 2023-24) Ground floor

75.05

915

68721.0335

... More
code178 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. (P.No.60, I.No.9.11-Vol-2 of PW, P&IWTD SR 2023-24) First floor

99

924

91559.16

... More
code179 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. (P.No.60, I.No.9.11-Vol-2 of PW, P&IWTD SR 2023-24) Second floor

99

934

92474.91

... More
code180 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. (P.No.60, I.No.9.11-Vol-2 of PW, P&IWTD SR 2023-24) Third floor

99

943

93399.57

... More
code181 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. (P.No.60, I.No.9.11-Vol-2 of PW, P&IWTD SR 2023-24) Fourth floor

99

952

94333.14

... More
code182 - Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (P.No.65, I.No.9.39 of PW, P&IWTD SR 2023-24)(vol-2) Ground floor

274.76

1492

410071.0572

... More
code183 - Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (P.No.65, I.No.9.39 of PW, P&IWTD SR 2023-24)(vol-2) First floor

211.56

1507

318907.6596

... More
code184 - Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (P.No.65, I.No.9.39 of PW, P&IWTD SR 2023-24)(vol-2) Second floor

211.56

1522

322093.7532

... More
code185 - Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (P.No.65, I.No.9.39 of PW, P&IWTD SR 2023-24)(vol-2) Third floor

211.56

1537

325315.812

... More
code186 - Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (P.No.65, I.No.9.39 of PW, P&IWTD SR 2023-24)(vol-2) Fourth floor

211.56

1553

328569.6048

... More
code187 - Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. (P.No.105, I.No.12.51 of PW, P&IWTD SR 2023-24)(vol-2) Ground floor

34

1046

35580.32

... More
code188 - Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. (P.No.105, I.No.12.51 of PW, P&IWTD SR 2023-24)(vol-2) First floor

36

1056

38049.84

... More
code189 - Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. (P.No.105, I.No.12.51 of PW, P&IWTD SR 2023-24)(vol-2) Second Floor

36

1067

38430.36

... More
code190 - Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. (P.No.105, I.No.12.51 of PW, P&IWTD SR 2023-24)(vol-2) Third floor

36

1078

38814.48

... More
code191 - Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. (P.No.105, I.No.12.51 of PW, P&IWTD SR 2023-24)(vol-2) Fourth floor

36

1088

39202.92

... More
code192 - Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. (P.No.105, I.No.12.51 of PW, P&IWTD SR 2023-24)(vol-2) Head room

2

1099

2199.7

... More
code193 - Providing White Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (P.No.100, I.No.12.13.1 of PW, P&IWTD SR 2023-24)(vol-2) (125x150mm) Ground floor

2.77

101779

281929.0765

... More
code194 - Providing White Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (P.No.100, I.No.12.13.1 of PW, P&IWTD SR 2023-24)(vol-2)(125x150mm) First floor

2.37

102797

243629.4588

... More
code195 - Providing White Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (P.No.100, I.No.12.13.1 of PW, P&IWTD SR 2023-24)(vol-2)(125x150mm) Second floor

2.37

103825

246065.7714

... More
code196 - Providing White Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (P.No.100, I.No.12.13.1 of PW, P&IWTD SR 2023-24)(vol-2)(125x150mm) Third floor

2.37

104863

248526.4476

... More
code197 - Providing White Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (P.No.100, I.No.12.13.1 of PW, P&IWTD SR 2023-24)(vol-2)(125x150mm) Fourth floor

2.37

105912

251011.7244

... More
code198 - Providing White Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (P.No.100, I.No.12.13.1 of PW, P&IWTD SR 2023-24)(vol-2)(125x150mm) Terrace floor

0.21

106971

22463.9604

... More
code199 - Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) (P.No.100, I.No.12.15 of PW, P&IWTD SR 2023-24)(vol-2)

17.28

7667

132491.2896

... More
code200 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 ( part-I) 1991. from manufacturer complete as per spcification. 30 mm thick both side commercial (P.No.105, I.No.12.57.3-Vol-2 of PW, P&IWTD SR 2023-2024) Ground floor

42.42

3095

131296.263

... More
code201 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 ( part-I) 1991. from manufacturer complete as per spcification. 30 mm thick both side commercial (P.No.105, I.No.12.57.3-Vol-2 of PW, P&IWTD SR 2023-2024) First floor

31.5

3126

98472.15

... More
code202 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 ( part-I) 1991. from manufacturer complete as per spcification. 30 mm thick both side commercial (P.No.105, I.No.12.57.3-Vol-2 of PW, P&IWTD SR 2023-2024) Second floor

31.5

3157

99456.84

... More
code203 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 ( part-I) 1991. from manufacturer complete as per spcification. 30 mm thick both side commercial (P.No.105, I.No.12.57.3-Vol-2 of PW, P&IWTD SR 2023-2024) Third floor

31.5

3188

100451.295

... More
code204 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 ( part-I) 1991. from manufacturer complete as per spcification. 30 mm thick both side commercial (P.No.105, I.No.12.57.3-Vol-2 of PW, P&IWTD SR 2023-2024) Fourth floor

31.5

3220

101455.83

... More
code205 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 ( part-I) 1991. from manufacturer complete as per spcification. 30 mm thick both side commercial (P.No.105, I.No.12.57.3-Vol-2 of PW, P&IWTD SR 2023-2024) Terrace Floor

4.2

3253

13662.726

... More
code206 - providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and crewed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) (P.No.110, I.No.12.93.2 -Vol-2 of PW, P&IWTD SR 2023-2024) Ground floor

79.2

786

62324.064

... More
code207 - providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and crewed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) (P.No.110, I.No.12.93.2 -Vol-2 of PW, P&IWTD SR 2023-2024) First floor

118.8

794

94421.052

... More
code208 - providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and crewed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) (P.No.110, I.No.12.93.2 -Vol-2 of PW, P&IWTD SR 2023-2024) Second floor

118.8

802

95356.008

... More
code209 - providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and crewed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) (P.No.110, I.No.12.93.2 -Vol-2 of PW, P&IWTD SR 2023-2024) Third floor

118.8

810

96290.964

... More
code210 - providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and crewed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) (P.No.110, I.No.12.93.2 -Vol-2 of PW, P&IWTD SR 2023-2024) Fourth floor

118.8

818

97225.92

... More
code211 - Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximumSl. No. Specification Unit RateKarnataka Public Works Department Volume-2KPWD VOL-2toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thickness (P.No.112, I.No.12.94.1 -Vol-2 of PW, P&IWTD SR 2023-2024) Ground floor

25.2

3589

90456.66

... More
code212 - Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximumSl. No. Specification Unit RateKarnataka Public Works Department Volume-2KPWD VOL-2toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thickness (P.No.112, I.No.12.94.1 -Vol-2 of PW, P&IWTD SR 2023-2024) First floor

37.8

3625

137042.01

... More
code213 - Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximumSl. No. Specification Unit RateKarnataka Public Works Department Volume-2KPWD VOL-2toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thickness (P.No.112, I.No.12.94.1 -Vol-2 of PW, P&IWTD SR 2023-2024) Second floor

37.8

3661

138411.882

... More
code214 - Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximumSl. No. Specification Unit RateKarnataka Public Works Department Volume-2KPWD VOL-2toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thickness (P.No.112, I.No.12.94.1 -Vol-2 of PW, P&IWTD SR 2023-2024) Third floor

37.8

3698

139796.496

... More
code215 - Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximumSl. No. Specification Unit RateKarnataka Public Works Department Volume-2KPWD VOL-2toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thickness (P.No.112, I.No.12.94.1 -Vol-2 of PW, P&IWTD SR 2023-2024) Fourth floor

37.8

3735

141194.34

... More
code216 - Providing & fixing of 3-track x 2-panel sliding windows made out of multichambered UPVC(Matching to RAL-9016) sections and with minimumTiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) andlead free, gaskets -grey colour having isolated drainage and reinforced withGalvanized Iron profile through-out the window frame. The outer framehaving an overall size of 108mm width x 45mmheight with reinforcementof 1mm thickness and Sash with overall size of 39mm x 75mm with GIreinforcement of 2mm and mesh sash of size 37mm x 58mm. CoextrudedGlazing bead for fixing of glass shall be of size 20mm x 24 mm. Windowsshall be provided with 6mm plain float glass, standard hardware& Multipoint locking system with touch lock. Wall thickness of frame & sash shallbe of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (Thecost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (P.No.110, I.No.12.90 of PW, P&IWTD SR 2023-24)(vol-2) Ground floor

54

6936

374545.08

... More
code217 - Providing & fixing of 3-track x 2-panel sliding windows made out of multichambered UPVC(Matching to RAL-9016) sections and with minimumTiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) andlead free, gaskets -grey colour having isolated drainage and reinforced withGalvanized Iron profile through-out the window frame. The outer framehaving an overall size of 108mm width x 45mmheight with reinforcementof 1mm thickness and Sash with overall size of 39mm x 75mm with GIreinforcement of 2mm and mesh sash of size 37mm x 58mm. CoextrudedGlazing bead for fixing of glass shall be of size 20mm x 24 mm. Windowsshall be provided with 6mm plain float glass, standard hardware& Multipoint locking system with touch lock. Wall thickness of frame & sash shallbe of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (Thecost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (P.No.110, I.No.12.90 of PW, P&IWTD SR 2023-24)(vol-2) First Floor

48.15

7005

337309.047

... More
code218 - Providing & fixing of 3-track x 2-panel sliding windows made out of multichambered UPVC(Matching to RAL-9016) sections and with minimumTiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) andlead free, gaskets -grey colour having isolated drainage and reinforced withGalvanized Iron profile through-out the window frame. The outer framehaving an overall size of 108mm width x 45mmheight with reinforcementof 1mm thickness and Sash with overall size of 39mm x 75mm with GIreinforcement of 2mm and mesh sash of size 37mm x 58mm. CoextrudedGlazing bead for fixing of glass shall be of size 20mm x 24 mm. Windowsshall be provided with 6mm plain float glass, standard hardware& Multipoint locking system with touch lock. Wall thickness of frame & sash shallbe of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (Thecost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (P.No.110, I.No.12.90 of PW, P&IWTD SR 2023-24)(vol-2) Second Floor

48.15

7075

340681.9545

... More
code219 - Providing & fixing of 3-track x 2-panel sliding windows made out of multichambered UPVC(Matching to RAL-9016) sections and with minimumTiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) andlead free, gaskets -grey colour having isolated drainage and reinforced withGalvanized Iron profile through-out the window frame. The outer framehaving an overall size of 108mm width x 45mmheight with reinforcementof 1mm thickness and Sash with overall size of 39mm x 75mm with GIreinforcement of 2mm and mesh sash of size 37mm x 58mm. CoextrudedGlazing bead for fixing of glass shall be of size 20mm x 24 mm. Windowsshall be provided with 6mm plain float glass, standard hardware& Multipoint locking system with touch lock. Wall thickness of frame & sash shallbe of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (Thecost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (P.No.110, I.No.12.90 of PW, P&IWTD SR 2023-24)(vol-2) Third Floor

48.15

7146

344088.567

... More
code220 - Providing & fixing of 3-track x 2-panel sliding windows made out of multichambered UPVC(Matching to RAL-9016) sections and with minimumTiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) andlead free, gaskets -grey colour having isolated drainage and reinforced withGalvanized Iron profile through-out the window frame. The outer framehaving an overall size of 108mm width x 45mmheight with reinforcementof 1mm thickness and Sash with overall size of 39mm x 75mm with GIreinforcement of 2mm and mesh sash of size 37mm x 58mm. CoextrudedGlazing bead for fixing of glass shall be of size 20mm x 24 mm. Windowsshall be provided with 6mm plain float glass, standard hardware& Multipoint locking system with touch lock. Wall thickness of frame & sash shallbe of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (Thecost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (P.No.110, I.No.12.90 of PW, P&IWTD SR 2023-24)(vol-2) Fourth Floor

48.15

7217

347529.366

... More
code221 - Providing & fixing of 3-track x 2-panel sliding windows made out of multichambered UPVC(Matching to RAL-9016) sections and with minimumTiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) andlead free, gaskets -grey colour having isolated drainage and reinforced withGalvanized Iron profile through-out the window frame. The outer framehaving an overall size of 108mm width x 45mmheight with reinforcementof 1mm thickness and Sash with overall size of 39mm x 75mm with GIreinforcement of 2mm and mesh sash of size 37mm x 58mm. CoextrudedGlazing bead for fixing of glass shall be of size 20mm x 24 mm. Windowsshall be provided with 6mm plain float glass, standard hardware& Multipoint locking system with touch lock. Wall thickness of frame & sash shallbe of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (Thecost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (P.No.110, I.No.12.90 of PW, P&IWTD SR 2023-24)(vol-2) Terrace Floor

2.16

7289

15746.0328

... More
code222 - Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (P.No.109, I.No.12.85 of PW, P&IWTD SR 2023-24)(vol-2) Ground floor

7.92

5890

46653.3144

... More
code223 - Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (P.No.109, I.No.12.85 of PW, P&IWTD SR 2023-24)(vol-2) First Floor

8.64

5949

51401.7792

... More
code224 - Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (P.No.109, I.No.12.85 of PW, P&IWTD SR 2023-24)(vol-2) Second Floor

8.64

6007

51909.0336

... More
code225 - Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (P.No.109, I.No.12.85 of PW, P&IWTD SR 2023-24)(vol-2) Third Floor

8.64

6071

52460.784

... More
code226 - Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (P.No.109, I.No.12.85 of PW, P&IWTD SR 2023-24)(vol-2) Fourth Floor

8.64

6129

52959.1392

... More
code227 - Providing and fixing M.S grills of required pattern in frames of windows etc . With M.S . Flat ,square or round bars etc . Including priming coat with approved steel primer all complete . Fixed to steel window by welding. (P.NO.86, volume-2, I.NO. 11.34A of PW, P&IWTD SR 2023-24)

5178.6

173

896104.944

... More
code228 - Main Door Providing and fixing fixtures for Door incluidng screws etc., complete as per specification and as per the directions by the Engineer in charge. Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete (P.No.105, Vol-2, I.No.12.60 of PW, P&IWTD SR 2023-24) Ground floor

12

1083

13002.72

... More
code229 - Providing and fixing fixtures for Door incluidng screws etc., complete as per specification and as per the directions by the Engineer in charge. Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete (P.No.105, Vol-2, I.No.12.60 of PW, P&IWTD SR 2023-24) First floor

16

1094

17510.4

... More
code230 - Providing and fixing fixtures for Door incluidng screws etc., complete as per specification and as per the directions by the Engineer in charge.. Providing and fixing bright finished brasstower bolts (barrel type) with necessary screws etc. complete : 250 x 10mm (P.No.107, Vol-2, I.No.12.76.1 of PW, P&IWTD SR 2023-24) Ground floor

114

448

51077.7

... More
code231 - Providing and fixing fixtures for Door incluidng screws etc., complete as per specification and as per the directions by the Engineer in charge.. Providing and fixing bright finished brasstower bolts (barrel type) with necessary screws etc. complete : 250 x 10mm (P.No.107, Vol-2, I.No.12.76.1 of PW, P&IWTD SR 2023-24) First floor

48

452

21721.44

... More
code232 - Providing and fixing fixtures for Door incluidng screws etc., complete as per specification and as per the directions by the Engineer in charge.. Providing and fixing bright finished brasstower bolts (barrel type) with necessary screws etc. complete : 250 x 10mm (P.No.107, Vol-2, I.No.12.76.1 of PW, P&IWTD SR 2023-24) Second floor

48

457

21938.4

... More
code233 - Providing and fixing fixtures for Door incluidng screws etc., complete as per specification and as per the directions by the Engineer in charge.. Providing and fixing bright finished brasstower bolts (barrel type) with necessary screws etc. complete : 250 x 10mm (P.No.107, Vol-2, I.No.12.76.1 of PW, P&IWTD SR 2023-24) Third floor

48

461

22157.76

... More
code234 - Providing and fixing fixtures for Door incluidng screws etc., complete as per specification and as per the directions by the Engineer in charge.. Providing and fixing bright finished brasstower bolts (barrel type) with necessary screws etc. complete : 250 x 10mm (P.No.107, Vol-2, I.No.12.76.1 of PW, P&IWTD SR 2023-24) Fourth floor

48

466

22379.04

... More
code235 - Providing and fixing fixtures for Door incluidng screws etc., complete as per specification and as per the directions by the Engineer in charge.. Providing and fixing bright finished brasstower bolts (barrel type) with necessary screws etc. complete : 250 x 10mm (P.No.107, Vol-2, I.No.12.76.1 of PW, P&IWTD SR 2023-24) terrace

6

470

2825.34

... More
code236 - Providing and fixing fixtures for Door incluidng screws etc., complete as per specification and as per the directions by the Engineer in charge. Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete (P.No.200, Vol-2, I.No.20.28 of PW, P&IWTD SR 2023-24) Ground floor

38

243

9237.04

... More
code237 - Providing and fixing fixtures for Door incluidng screws etc., complete as per specification and as per the directions by the Engineer in charge. Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete (P.No.200, Vol-2, I.No.20.28 of PW, P&IWTD SR 2023-24) First floor

16

245

3928.16

... More
code238 - Providing and fixing fixtures for Door incluidng screws etc., complete as per specification and as per the directions by the Engineer in charge. Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete (P.No.200, Vol-2, I.No.20.28 of PW, P&IWTD SR 2023-24) Second floor

16

247

3967.36

... More
code239 - Providing and fixing fixtures for Door incluidng screws etc., complete as per specification and as per the directions by the Engineer in charge. Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete (P.No.200, Vol-2, I.No.20.28 of PW, P&IWTD SR 2023-24) Third floor

16

250

4006.88

... More
code240 - Providing and fixing fixtures for Door incluidng screws etc., complete as per specification and as per the directions by the Engineer in charge. Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete (P.No.200, Vol-2, I.No.20.28 of PW, P&IWTD SR 2023-24) Fourth floor

16

252

4047.04

... More
code241 - Providing and fixing fixtures for Door incluidng screws etc., complete as per specification and as per the directions by the Engineer in charge. Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete (P.No.200, Vol-2, I.No.20.28 of PW, P&IWTD SR 2023-24) terrace

2

255

510.92

... More
code242 - Providing and fixing fixtures for Door incluidng screws etc., complete as per specification and as per the directions by the Engineer in charge. Providing and fixing bright finished brass handles with screws etc. complete: Brass handles 125mm with plate 175x32 mm (P.No.108, Vol-2, I.No.12.79.1 of PW, P&IWTD SR 2023-24) Ground floor

76

256

19491.72

... More
code243 - Providing and fixing fixtures for Door incluidng screws etc., complete as per specification and as per the directions by the Engineer in charge. Providing and fixing bright finished brass handles with screws etc. complete: Brass handles 125mm with plate 175x32 mm (P.No.108, Vol-2, I.No.12.79.1 of PW, P&IWTD SR 2023-24) First floor

32

259

8289.6

... More
code244 - Providing and fixing fixtures for Door incluidng screws etc., complete as per specification and as per the directions by the Engineer in charge. Providing and fixing bright finished brass handles with screws etc. complete: Brass handles 125mm with plate 175x32 mm (P.No.108, Vol-2, I.No.12.79.1 of PW, P&IWTD SR 2023-24) Second floor

32

261

8372.16

... More
code245 - Providing and fixing fixtures for Door incluidng screws etc., complete as per specification and as per the directions by the Engineer in charge. Providing and fixing bright finished brass handles with screws etc. complete: Brass handles 125mm with plate 175x32 mm (P.No.108, Vol-2, I.No.12.79.1 of PW, P&IWTD SR 2023-24) Third floor

32

264

8456

... More
code246 - Providing and fixing fixtures for Door incluidng screws etc., complete as per specification and as per the directions by the Engineer in charge. Providing and fixing bright finished brass handles with screws etc. complete: Brass handles 125mm with plate 175x32 mm (P.No.108, Vol-2, I.No.12.79.1 of PW, P&IWTD SR 2023-24) Fourth floor

32

266

8540.16

... More
code247 - Providing and fixing fixtures for Door incluidng screws etc., complete as per specification and as per the directions by the Engineer in charge. Providing and fixing bright finished brass handles with screws etc. complete: Brass handles 125mm with plate 175x32 mm (P.No.108, Vol-2, I.No.12.79.1 of PW, P&IWTD SR 2023-24) terrace

4

269

1077.84

... More
code248 - Providing and fixing fixtures for Door incluidng screws etc., complete as per specification and as per the directions by the Engineer in charge. Providing and fixing bright finished brass butt hinges with necessary screws etc.: complete125x85x5.5 mm (heavy type) : (P.No.107, Vol-2, I.No.12.75.1 of PW, P&IWTD SR 2023-24) Ground floor

152

283

43054

... More
code249 - Providing and fixing fixtures for Door incluidng screws etc., complete as per specification and as per the directions by the Engineer in charge. Providing and fixing bright finished brass butt hinges with necessary screws etc.: complete125x85x5.5 mm (heavy type) : (P.No.107, Vol-2, I.No.12.75.1 of PW, P&IWTD SR 2023-24) First floor

64

286

18309.12

... More
code250 - Providing and fixing fixtures for Door incluidng screws etc., complete as per specification and as per the directions by the Engineer in charge. Providing and fixing bright finished brass butt hinges with necessary screws etc.: complete125x85x5.5 mm (heavy type) : (P.No.107, Vol-2, I.No.12.75.1 of PW, P&IWTD SR 2023-24)Second floor

64

288

18492.8

... More
code251 - Providing and fixing fixtures for Door incluidng screws etc., complete as per specification and as per the directions by the Engineer in charge. Providing and fixing bright finished brass butt hinges with necessary screws etc.: complete125x85x5.5 mm (heavy type) : (P.No.107, Vol-2, I.No.12.75.1 of PW, P&IWTD SR 2023-24) Third floor

64

291

18677.12

... More
code252 - Providing and fixing fixtures for Door incluidng screws etc., complete as per specification and as per the directions by the Engineer in charge. Providing and fixing bright finished brass butt hinges with necessary screws etc.: complete125x85x5.5 mm (heavy type) : (P.No.107, Vol-2, I.No.12.75.1 of PW, P&IWTD SR 2023-24) Fourth floor

64

294

18863.36

... More
code253 - Providing and fixing fixtures for Door incluidng screws etc., complete as per specification and as per the directions by the Engineer in charge. Providing and fixing bright finished brass butt hinges with necessary screws etc.: complete125x85x5.5 mm (heavy type) : (P.No.107, Vol-2, I.No.12.75.1 of PW, P&IWTD SR 2023-24) terrace

8

269

2155.68

... More
code254 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (P.No.85, I.No.11.28 of PW, P&IWTD SR 2023-24)(vol-2) Ground floor

462.5

581

269151.875

... More
code255 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (P.No.85, I.No.11.28 of PW, P&IWTD SR 2023-24)(vol-2) First floor to second floor

187.5

587

110206.875

... More
code256 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (P.No.85, I.No.11.28 of PW, P&IWTD SR 2023-24)(vol-2) Third floor to Fourth floor

187.5

599

112421.25

... More
code257 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (P.No.85, I.No.11.28 of PW, P&IWTD SR 2023-24)(vol-2) Fourth floor to terrace

187.5

605

113546.25

... More
code258 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (P.No.41, I.No.8.2.2 of PW, P&IWTD SR 2023-24)(vol-2) Ground Floor

274.76

287

78957.7812

... More
code259 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (P.No.41, I.No.8.2.2 of PW, P&IWTD SR 2023-24)(vol-2) First floor

211.56

290

61403.1744

... More
code260 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (P.No.41, I.No.8.2.2 of PW, P&IWTD SR 2023-24)(vol-2) Second floor

211.56

293

62016.6984

... More
code261 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (P.No.41, I.No.8.2.2 of PW, P&IWTD SR 2023-24)(vol-2) Third floor

211.56

296

62636.5692

... More
code262 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (P.No.41, I.No.8.2.2 of PW, P&IWTD SR 2023-24)(vol-2) Fourth floor

211.56

299

63262.7868

... More
code263 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (P.No.50, I.No.8.51 of PW, P&IWTD SR 2023-24)(vol-2) Ground floor

1263.61

103

130151.83

... More
code264 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (P.No.50, I.No.8.51 of PW, P&IWTD SR 2023-24)(vol-2) First floor

1874.9

104

195045.847

... More
code265 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (P.No.50, I.No.8.51 of PW, P&IWTD SR 2023-24)(vol-2) Second floor

1874.9

105

196995.743

... More
code266 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (P.No.50, I.No.8.51 of PW, P&IWTD SR 2023-24)(vol-2) Third floor

1874.9

106

198964.388

... More
code267 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (P.No.50, I.No.8.51 of PW, P&IWTD SR 2023-24)(vol-2) Fourth floor

1874.9

107

200951.782

... More
code268 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (P.No.50, I.No.8.51 of PW, P&IWTD SR 2023-24)(vol-2) Head room

135.18

108

14633.235

... More
code269 - Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge (P.No.46, I.No.8.32 Vol-2 of PW, P&IWTD SR 2023-24) Ground floor

1263.61

160

203036.8548

... More
code270 - Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge (P.No.46, I.No.8.32 Vol-2 of PW, P&IWTD SR 2023-24) First floor

1874.9

162

304277.521

... More
code271 - Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge (P.No.46, I.No.8.32 Vol-2 of PW, P&IWTD SR 2023-24) Second floor

1874.9

163

307296.11

... More
code272 - Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge (P.No.46, I.No.8.32 Vol-2 of PW, P&IWTD SR 2023-24) Third floor

1874.9

165

310370.946

... More
code273 - Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge (P.No.46, I.No.8.32 Vol-2 of PW, P&IWTD SR 2023-24) Fourth floor

1874.9

167

313483.28

... More
code274 - Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge (P.No.46, I.No.8.32 Vol-2 of PW, P&IWTD SR 2023-24) Head room

135.18

168

22829.1984

... More
code275 - External painting Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (P.No.46, I.No.8.30 of PW, P&IWTD SR 2023-24)(vol-2) Ground floor

622.66

179

111593.1252

... More
code276 - External painting Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (P.No.46, I.No.8.30 of PW, P&IWTD SR 2023-24)(vol-2) First floor

594.67

181

107641.2167

... More
code277 - External painting Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (P.No.46, I.No.8.30 of PW, P&IWTD SR 2023-24)(vol-2) Second floor

594.67

182

108711.6227

... More
code278 - External painting Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (P.No.46, I.No.8.30 of PW, P&IWTD SR 2023-24)(vol-2) Third floor

594.67

184

109805.8155

... More
code279 - External painting Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (P.No.46, I.No.8.30 of PW, P&IWTD SR 2023-24)(vol-2) Fourth floor

594.67

186

110900.0083

... More
code280 - External painting Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (P.No.46, I.No.8.30 of PW, P&IWTD SR 2023-24)(vol-2) Head room + Parapet

356.41

188

67133.3876

... More
code281 - Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (P.No.48, I.No.8.40 of PW, P&IWTD SR 2023-24)(vol-2) Grill work windows and ventilators

291.24

118

34497.378

... More
code282 - Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(P.No.48, I.No.8.40 of PW, P&IWTD SR 2023-24)(vol-2) Ground floor

59.7

118

7071.465

... More
code283 - Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(P.No.48, I.No.8.40 of PW, P&IWTD SR 2023-24)(vol-2) First floor

31.5

119

3768.345

... More
code284 - Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(P.No.48, I.No.8.40 of PW, P&IWTD SR 2023-24)(vol-2) Second floor

31.5

120

3806.145

... More
code285 - Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(P.No.48, I.No.8.40 of PW, P&IWTD SR 2023-24)(vol-2) Third floor

31.5

122

3843.945

... More
code286 - Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(P.No.48, I.No.8.40 of PW, P&IWTD SR 2023-24)(vol-2) Fourth floor

31.5

123

3882.375

... More
code287 - Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(P.No.48, I.No.8.40 of PW, P&IWTD SR 2023-24)(vol-2) Head room

4.2

124

522.858

... More
code288 - providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU wa x005fterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surfacepreparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.(P.No.149, I.No.15.1-Vol-2 of PW, P&IWTD SR 2023-24) Terrace Area

535.61

841

450721.1711

... More
code289 - Providing and Applying CFTRI approved two component flexible polymer modified acrylic cementitious waterproofing coating with a mix ratio of (5 Liquid :7 Powder) to the RCC surface like Roof, bathroom, toilet, balcony & utility area applied @ 2.2kg/m2 in 2 coats to achieve 1.2mm DFT, having Elongation at break Greater than120% as per ASTM D 412, Tensile strength Greater than1N mm2 as per ASTM D 412, Adhesion strength: 0.80N/mm2 as per ASTM D 4541, crack bridging upto 2mm as per ASTM C 836. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 45 gsm glass fibre mesh over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification. (P.No.152, I.No.15.11-Vol-2 of PW, P&IWTD SR 2023-24)

74.9

540

40502.175

... More
code290 - providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width,along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 200mm wide (P.NO.44,I.NO. 8.16.3, Vol-2 OF PW,P&IWTD SR (2023-24) Ground floor

850

45

38522

... More
code291 - providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width,along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 200mm wide (P.NO.44,I.NO. 8.16.3, Vol-2 OF PW,P&IWTD SR (2023-24) first floor

1300

45

59501

... More
code292 - providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width,along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 200mm wide (P.NO.44,I.NO. 8.16.3, Vol-2 OF PW,P&IWTD SR (2023-24) Second floor

1300

46

60840

... More
code293 - providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width,along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 200mm wide (P.NO.44,I.NO. 8.16.3, Vol-2 OF PW,P&IWTD SR (2023-24) Third floor

1300

47

61451

... More
code294 - providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width,along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 200mm wide (P.NO.44,I.NO. 8.16.3, Vol-2 OF PW,P&IWTD SR (2023-24) Fourth floor

1300

47

62062

... More
code295 - Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (P.No.77, I.No.11.5.1 of PW, P&IWTD SR 2023-24)(vol-2) Ground floor

2.52

4612

11623.0968

... More
code296 - Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (P.No.77, I.No.11.5.1 of PW, P&IWTD SR 2023-24)(vol-2) First floor

2.52

4658

11739.3192

... More
code297 - Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (P.No.77, I.No.11.5.1 of PW, P&IWTD SR 2023-24)(vol-2) Second floor

2.52

4705

11856.7008

... More
code298 - Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (P.No.77, I.No.11.5.1 of PW, P&IWTD SR 2023-24)(vol-2) Third floor

2.52

4752

11975.2668

... More
code299 - Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (P.No.77, I.No.11.5.1 of PW, P&IWTD SR 2023-24)(vol-2) Fourth floor

2.52

4799

12095.0172

... More
code300 - Providing & Fixing of Integral Densified Tegular/Butt edged Eco Friendly Lightweight Calcium Silicate Suspended Ceiling System in Module Size of 600x600x15mm with Exposed GI Plain T24 Grid for Offices, Hos- pitals, Institutions, Airports, Banking Sector, Auditoriums, Community halls, laboratories, Factories and All buildings in high humidity or coastal Areas. The Eco Friendly Lightweight Calcium Silicate Ceiling tiles shall be made from Non Cementitious Hydrated Calcium Silicate Slurry/ Mixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials. Doesn't contain any toxic ingredients.The Tiles should have Humidity Resistance (RH) of 100%, Water Resistance, Non Combustible: as per BS:476 Part-4, Fire Performance: as per BS:476 Part-6 for Fire Propagation, as per BS:476 Part-7 for Surface Spread of Flame, As per UK standards Fire Performace A1-S1-d0, Thermal Conductivity K= 0.048 to 0.050 w/m K as per ECBC code 2007, NRC (Noise Reductions Coefficient) 0.5 to 0.75 (Semi Perforated & Fully Perforated Tiles) as per IS 8225:1987, Sound Attenuation (STA) 30-32dB,Thickness of tile should be 15mm thick with 450 kg/m3 density all around on edge resting portion with Integral Densified edge and 10mm thick with 350 kg/m3 density in the center of the body, Light Reflectance Greater than 85%, Weight of material is 5-5.5 kg/m2 and Suitable for Green Building application with InOrganic Recycled content of 46- 50% out of which 18-20% should be FLYASH and meets the GRIHA & SVAGRIHA norms under the categories: GRIHA V.2015 criterion:11&12, GRIHA V.3 criterion: 17&29 and SVAGRIHA criterion:12 The tiles Shall be laid on 24mm Wide T-Sections Flanges colour white having rotary stitching on all T sections i.e. the Main runner with a web height of 38mm and 1200mm & 600mm Cross Tees with a web height of 32mm having thickness of 0.33mm and Wall angle of 24*24mm with0.4 mm thickness , having load carrying capacity of 15 kg/m2. The T sections should have Galvanizing of 120 grams per m2 and need to be installed with Suspension system P.NO-33 ,I.NO-7.54,VOL-2. SR-23.24

101.88

1943

198014.9868

... More
code301 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(P.No.17, Vol- 2 , I.No.6.33 of PW, P&IWTD SR 2023-24) For portico steps

54.18

1267

68696.4474

... More
code302 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge(P.No.46, Vol- 2 , I.No.8.2.2 of PW, P&IWTD SR 2023-24)

28.61

287

8221.6557

... More
code303 - providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finx005fished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications (P.No.64, Vol- 2 , I.No.9.30 of PW, P&IWTD SR 2023-24)

21.68

5487

118976.3712

... More
code304 - A. SANITARY FIXTURES Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps.(Comn-SR V-2, Item No - 14.7.3) Ground Floor

24

2972

71341.92

... More
code305 - Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps.(Comn-SR V-2, Item No - 14.7.3) First floor

20

2972

59451.6

... More
code306 - Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps.(Comn-SR V-2, Item No - 14.7.3) Second floor

20

2972

59451.6

... More
code307 - Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps.(Comn-SR V-2, Item No - 14.7.3) Third floor

20

2972

59451.6

... More
code308 - Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps.(Comn-SR V-2, Item No - 14.7.3) Fourth floor

20

2972

59451.6

... More
code309 - Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover,and cistern fittings, nuts, bolts and gasket etc complete (Comn-SR V-2, Item No - 14.44) Ground Floor

8

11560

92485.76

... More
code310 - Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover,and cistern fittings, nuts, bolts and gasket etc complete (Comn-SR V-2, Item No - 14.44) First floor

10

11560

115607.2

... More
code311 - Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover,and cistern fittings, nuts, bolts and gasket etc complete (Comn-SR V-2, Item No - 14.44) Second floor

10

11560

115607.2

... More
code312 - Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover,and cistern fittings, nuts, bolts and gasket etc complete (Comn-SR V-2, Item No - 14.44) Third floor

10

11560

115607.2

... More
code313 - Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover,and cistern fittings, nuts, bolts and gasket etc complete (Comn-SR V-2, Item No - 14.44) Fourth floor

10

11560

115607.2

... More
code314 - Providing and fixing CP. Health faucet with flexible hose,CP Bibcock with 2 in 1 connectvity, wall flange, supporting hook with screws, fixing materials and sealant to all sides of wall flange complete. (Market Rate) Ground Floor, 1st, 2nd, 3rd & 4th floor

48

3000

144000

... More
code315 - Providing and fixing Single lever wall mixer with L shaped Tubular bend set for overhead shower made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class (Comn-SR V-2, Item No - 14.60.a) Economy Ground Floor

44

4104

180600.2

... More
code316 - Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 (Comn-SR V-2, Item No - 13.12) Ground Floor, 1st, 2nd, 3rd & 4th floor

50

654

32702.5

... More
code317 - Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.(Comn-SR V-2, Item No - 13.15) Ground Floor, 1st, 2nd, 3rd & 4th floor

241

746

179966.75

... More
code318 - Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.(Comn-SR V-2, Item No - 14.31) Ground Floor

9

1256

11309.4

... More
code319 - Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.(Comn-SR V-2, Item No - 14.31) First floor

4

1256

5026.4

... More
code320 - Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.(Comn-SR V-2, Item No - 14.31) Second floor

4

1256

5026.4

... More
code321 - Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.(Comn-SR V-2, Item No - 14.31) Third floor

4

1256

5026.4

... More
code322 - Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.(Comn-SR V-2, Item No - 14.31) Fourth floor

4

1256

5026.4

... More
code323 - 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.(Comn-SR V-2, Item No - 14.40.2) Ground Floor

2

510

1021.76

... More
code324 - 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.(Comn-SR V-2, Item No - 14.40.2) First Floor

10

510

5108.8

... More
code325 - 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.(Comn-SR V-2, Item No - 14.40.2) Second Floor

10

510

5108.8

... More
code326 - 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.(Comn-SR V-2, Item No - 14.40.2) Third floor

10

510

5108.8

... More
code327 - 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.(Comn-SR V-2, Item No - 14.40.2) Fourth floor

10

510

5108.8

... More
code328 - B. INTERNAL SEWERAGE SYSTEM Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.(Comn-SR V-2, Item No - 14.28) Flexible pipe-40mm Dia (Comn-SR V-2, Item No - 14.28.2.2) Ground Floor

24

94

2274.24

... More
code329 - Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.(Comn-SR V-2, Item No - 14.28) Flexible pipe-40mm Dia (Comn-SR V-2, Item No - 14.28.2.2) First floor

20

94

1895.2

... More
code330 - Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.(Comn-SR V-2, Item No - 14.28) Flexible pipe-40mm Dia (Comn-SR V-2, Item No - 14.28.2.2) Second floor

20

94

1895.2

... More
code331 - Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.(Comn-SR V-2, Item No - 14.28) Flexible pipe-40mm Dia (Comn-SR V-2, Item No - 14.28.2.2) Third floor

20

94

1895.2

... More
code332 - Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.(Comn-SR V-2, Item No - 14.28) Flexible pipe-40mm Dia (Comn-SR V-2, Item No - 14.28.2.2) Fourth floor

20

94

1895.2

... More
code333 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:(Comn-SR V-5,Item No -10.1) PVC pipes 75 mm dia., 6 kg/sqcm & class 3 (Comn-SR V-5, Item No -10.1.5) Ground Floor

50

226

11330

... More
code334 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:(Comn-SR V-5,Item No -10.1) PVC pipes 75 mm dia., 6 kg/sqcm & class 3 (Comn-SR V-5, Item No -10.1.5) First floor

50

226

11330

... More
code335 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:(Comn-SR V-5,Item No -10.1) PVC pipes 75 mm dia., 6 kg/sqcm & class 3 (Comn-SR V-5, Item No -10.1.5) Second floor

50

226

11330

... More
code336 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:(Comn-SR V-5,Item No -10.1) PVC pipes 75 mm dia., 6 kg/sqcm & class 3 (Comn-SR V-5, Item No -10.1.5) Third floor

50

226

11330

... More
code337 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:(Comn-SR V-5,Item No -10.1) PVC pipes 75 mm dia., 6 kg/sqcm & class 3 (Comn-SR V-5, Item No -10.1.5) Fourth floor

50

226

11330

... More
code338 - Supplying of special moulded variety PVC couplers as per IS 7834/1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc. complete.(Comn-SR V-5,Item No -10.8) 75mm dia PVC Couplers (Comn-SR V-5, Item No -10.8.6) Ground Floor

10

69

690.1

... More
code339 - Supplying of special moulded variety PVC couplers as per IS 7834/1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc. complete.(Comn-SR V-5,Item No -10.8) 75mm dia PVC Couplers (Comn-SR V-5, Item No -10.8.6) First floor

10

69

690.1

... More
code340 - Supplying of special moulded variety PVC couplers as per IS 7834/1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc. complete.(Comn-SR V-5,Item No -10.8) 75mm dia PVC Couplers (Comn-SR V-5, Item No -10.8.6) Second floor

10

69

690.1

... More
code341 - Supplying of special moulded variety PVC couplers as per IS 7834/1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc. complete.(Comn-SR V-5,Item No -10.8) 75mm dia PVC Couplers (Comn-SR V-5, Item No -10.8.6) Third floor

10

69

690.1

... More
code342 - Supplying of special moulded variety PVC couplers as per IS 7834/1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc. complete.(Comn-SR V-5,Item No -10.8) 75mm dia PVC Couplers (Comn-SR V-5, Item No -10.8.6) Fourth floor

10

69

690.1

... More
code343 - Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.9) 75mm dia PVC Elbows (Comn-SR V-5, Item No -10.9.6) Ground Floor

10

197

1977.6

... More
code344 - Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.9) 75mm dia PVC Elbows (Comn-SR V-5, Item No -10.9.6) First floor

10

197

1977.6

... More
code345 - Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.9) 75mm dia PVC Elbows (Comn-SR V-5, Item No -10.9.6) Second floor

10

197

1977.6

... More
code346 - Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.9) 75mm dia PVC Elbows (Comn-SR V-5, Item No -10.9.6) Third floor

10

197

1977.6

... More
code347 - Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.9) 75mm dia PVC Elbows (Comn-SR V-5, Item No -10.9.6) Fourth floor

10

197

1977.6

... More
code348 - Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.10) 75mm dia PVC Tee (Comn-SR V-5, Item No -10.10.6) Ground Floor

10

120

1205.1

... More
code349 - Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.10) 75mm dia PVC Tee (Comn-SR V-5, Item No -10.10.6) First floor

10

120

1205.1

... More
code350 - Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.10) 75mm dia PVC Tee (Comn-SR V-5, Item No -10.10.6) Second floor

10

120

1205.1

... More
code351 - Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.10) 75mm dia PVC Tee (Comn-SR V-5, Item No -10.10.6) Third floor

10

120

1205.1

... More
code352 - Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.10) 75mm dia PVC Tee (Comn-SR V-5, Item No -10.10.6) Fourth floor

10

120

1205.1

... More
code353 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:(Comn-SR V-5,Item No -10.1) PVC pipes 110 mm dia., 6 kg/sqcm & class 3 (Comn-SR V-5, Item No -10.1.7) Ground Floor

20

423

8466.6

... More
code354 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:(Comn-SR V-5,Item No -10.1) PVC pipes 110 mm dia., 6 kg/sqcm & class 3 (Comn-SR V-5, Item No -10.1.7) First floor

40

423

16933.2

... More
code355 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:(Comn-SR V-5,Item No -10.1) PVC pipes 110 mm dia., 6 kg/sqcm & class 3 (Comn-SR V-5, Item No -10.1.7) Second floor

40

423

16933.2

... More
code356 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:(Comn-SR V-5,Item No -10.1) PVC pipes 110 mm dia., 6 kg/sqcm & class 3 (Comn-SR V-5, Item No -10.1.7) Third floor

40

423

16933.2

... More
code357 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:(Comn-SR V-5,Item No -10.1) PVC pipes 110 mm dia., 6 kg/sqcm & class 3 (Comn-SR V-5, Item No -10.1.7) Fourth floor

40

423

16933.2

... More
code358 - Supplying of special moulded variety PVC couplers as per IS 7834/1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc. complete.(Comn-SR V-5,Item No -10.8) 110mm dia PVC Couplers (Comn-SR V-5, Item No -10.8.8) Ground Floor

8

176

1409.04

... More
code359 - Supplying of special moulded variety PVC couplers as per IS 7834/1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc. complete.(Comn-SR V-5,Item No -10.8) 110mm dia PVC Couplers (Comn-SR V-5, Item No -10.8.8) First floor

8

176

1409.04

... More
code360 - Supplying of special moulded variety PVC couplers as per IS 7834/1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc. complete.(Comn-SR V-5,Item No -10.8) 110mm dia PVC Couplers (Comn-SR V-5, Item No -10.8.8) Second floor

8

176

1409.04

... More
code361 - Supplying of special moulded variety PVC couplers as per IS 7834/1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc. complete.(Comn-SR V-5,Item No -10.8) 110mm dia PVC Couplers (Comn-SR V-5, Item No -10.8.8) Third floor

8

176

1409.04

... More
code362 - Supplying of special moulded variety PVC couplers as per IS 7834/1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc. complete.(Comn-SR V-5,Item No -10.8) 110mm dia PVC Couplers (Comn-SR V-5, Item No -10.8.8) Fourth floor

8

176

1409.04

... More
code363 - Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.9) 110mm dia PVC Elbows (Comn-SR V-5, Item No -10.9.8) Ground Floor

8

311

2488.48

... More
code364 - Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.9) 110mm dia PVC Elbows (Comn-SR V-5, Item No -10.9.8) First floor

8

311

2488.48

... More
code365 - Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.9) 110mm dia PVC Elbows (Comn-SR V-5, Item No -10.9.8) Second floor

8

311

2488.48

... More
code366 - Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.9) 110mm dia PVC Elbows (Comn-SR V-5, Item No -10.9.8) Third floor

8

311

2488.48

... More
code367 - Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.9) 110mm dia PVC Elbows (Comn-SR V-5, Item No -10.9.8) Fourth floor

8

311

2488.48

... More
code368 - Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.10) 110mm dia PVC Tee (Comn-SR V-5, Item No -10.10.8) Ground Floor

8

258

2068.24

... More
code369 - Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.10) 110mm dia PVC Tee (Comn-SR V-5, Item No -10.10.8) First floor

8

258

2068.24

... More
code370 - Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.10) 110mm dia PVC Tee (Comn-SR V-5, Item No -10.10.8) Second floor

8

258

2068.24

... More
code371 - Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.10) 110mm dia PVC Tee (Comn-SR V-5, Item No -10.10.8) Third floor

8

258

2068.24

... More
code372 - Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.10) 110mm dia PVC Tee (Comn-SR V-5, Item No -10.10.8) Fourth floor

8

258

2068.24

... More
code373 - Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete (Comn-SR V-2, Item No - 13.63) Ground, 1st, 2nd, 3rd &4th floor

145

251

36441.4

... More
code374 - Providing and fixing PTMT grating of approved quality and colour.Rectangular type with openable circular lid. (Comn-SR V-2, Item No - 13.22.2) Ground, 1st, 2nd, 3rd &4th floor

145

208

30168.7

... More
code375 - Providing and grouting sleeves made in beam/ slab to draw waste and soil lines at all floor level of the below mentioned sizes , including condcting water ponding test to ensure zero leakage with all leads and lifts complete Size : 150 mm dia(MR)Ground, 1st, 2nd, 3rd &4th floor

100

720

72000

... More
code376 - C. INTERNAL WATER SUPPLY SYSTEM Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement testing of joints complete as per direction of Engineer in charge, concealed work, including cutting chases and making good the wall etc.,.20mm nominal dia (Comn-SR V-2, Item No - 13.32.2) 20mm nominal OD pipes(Comn-SR V-2, Item No - 13.32.2) Ground Floor

55

390

21470.35

... More
code377 - Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement testing of joints complete as per direction of Engineer in charge, concealed work, including cutting chases and making good the wall etc.,.20mm nominal dia (Comn-SR V-2, Item No - 13.32.2) 20mm nominal OD pipes(Comn-SR V-2, Item No - 13.32.2) First floor

80

390

31229.6

... More
code378 - Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement testing of joints complete as per direction of Engineer in charge, concealed work, including cutting chases and making good the wall etc.,.20mm nominal dia (Comn-SR V-2, Item No - 13.32.2) 20mm nominal OD pipes(Comn-SR V-2, Item No - 13.32.2) Second floor

80

390

31229.6

... More
code379 - Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement testing of joints complete as per direction of Engineer in charge, concealed work, including cutting chases and making good the wall etc.,.20mm nominal dia (Comn-SR V-2, Item No - 13.32.2) 20mm nominal OD pipes(Comn-SR V-2, Item No - 13.32.2) Third floor

80

390

31229.6

... More
code380 - Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement testing of joints complete as per direction of Engineer in charge, concealed work, including cutting chases and making good the wall etc.,.20mm nominal dia (Comn-SR V-2, Item No - 13.32.2) 20mm nominal OD pipes(Comn-SR V-2, Item No - 13.32.2) Fourth floor

80

390

31229.6

... More
code381 - 20mm nominal OD pipes(Comn-SR V-2, Item No - 13.32.3) Ground Floor

10

491

4913.1

... More
code382 - 20mm nominal OD pipes(Comn-SR V-2, Item No - 13.32.3) First Floor

40

491

19652.4

... More
code383 - 20mm nominal OD pipes(Comn-SR V-2, Item No - 13.32.3) Second floor

40

491

19652.4

... More
code384 - 20mm nominal OD pipes(Comn-SR V-2, Item No - 13.32.3) Third floor

40

491

19652.4

... More
code385 - 20mm nominal OD pipes(Comn-SR V-2, Item No - 13.32.3) Fourth floor

40

491

19652.4

... More
code386 - Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :(Comn-SR V-2, Item No - 13.5) 20mm nominal bore(Comn-SR V-2, Item No - 13.5.2) Ground Floor

4

323

1293.68

... More
code387 - Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :(Comn-SR V-2, Item No - 13.5) 25mm nominal bore(Comn-SR V-2, Item No - 13.5.3) Ground Floor

4

341

1367.84

... More
code388 - Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :(Comn-SR V-2, Item No - 13.5) 25mm nominal bore(Comn-SR V-2, Item No - 13.5.3) First floor

4

341

1367.84

... More
code389 - Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :(Comn-SR V-2, Item No - 13.5) 25mm nominal bore(Comn-SR V-2, Item No - 13.5.3) Second floor

4

341

1367.84

... More
code390 - Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :(Comn-SR V-2, Item No - 13.5) 25mm nominal bore(Comn-SR V-2, Item No - 13.5.3) Third floor

4

341

1367.84

... More
code391 - Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :(Comn-SR V-2, Item No - 13.5) 25mm nominal bore(Comn-SR V-2, Item No - 13.5.3) Fourth floor

4

341

1367.84

... More
code392 - D. EXTERNAL WATER SUPPLY SYSTEM Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work(Comn-SR V-1, Item No -13.33) 20 mm nominal OD Pipes(Comn-SR V-1, Item No -13.33.2) Ground floor

40

223

8940.4

... More
code393 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work(Comn-SR V-1, Item No -13.33) 20 mm nominal OD Pipes(Comn-SR V-1, Item No -13.33.2) First floor

40

223

8940.4

... More
code394 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work(Comn-SR V-1, Item No -13.33) 20 mm nominal OD Pipes(Comn-SR V-1, Item No -13.33.2) Second floor

40

223

8940.4

... More
code395 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work(Comn-SR V-1, Item No -13.33) 20 mm nominal OD Pipes(Comn-SR V-1, Item No -13.33.2) Third floor

40

223

8940.4

... More
code396 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work(Comn-SR V-1, Item No -13.33) 20 mm nominal OD Pipes(Comn-SR V-1, Item No -13.33.2) Fourth floor

40

223

8940.4

... More
code397 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work(Comn-SR V-1, Item No -13.33) 25 mm nominal OD Pipes(Comn-SR V-1, Item No -13.33.3) Ground floor

35

304

10670.8

... More
code398 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work(Comn-SR V-1, Item No -13.33) 25 mm nominal OD Pipes(Comn-SR V-1, Item No -13.33.3) First floor

24

304

7317.12

... More
code399 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work(Comn-SR V-1, Item No -13.33) 25 mm nominal OD Pipes(Comn-SR V-1, Item No -13.33.3) Second floor

24

304

7317.12

... More
code400 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work(Comn-SR V-1, Item No -13.33) 25 mm nominal OD Pipes(Comn-SR V-1, Item No -13.33.3) Third floor

24

304

7317.12

... More
code401 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work(Comn-SR V-1, Item No -13.33) 25 mm nominal OD Pipes(Comn-SR V-1, Item No -13.33.3) Fourth floor

24

304

7317.12

... More
code402 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work(Comn-SR V-1, Item No -13.33) 32 mm nominal OD Pipes(Comn-SR V-1, Item No -13.33.4) Ground floor

66

383

25288.56

... More
code403 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work(Comn-SR V-1, Item No -13.33) 32 mm nominal OD Pipes(Comn-SR V-1, Item No -13.33.4) First floor

30

383

11494.8

... More
code404 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work(Comn-SR V-1, Item No -13.33) 32 mm nominal OD Pipes(Comn-SR V-1, Item No -13.33.4) Second floor

30

383

11494.8

... More
code405 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work(Comn-SR V-1, Item No -13.33) 32 mm nominal OD Pipes(Comn-SR V-1, Item No -13.33.4) Third floor

86

383

32951.76

... More
code406 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work(Comn-SR V-1, Item No -13.33) 32 mm nominal OD Pipes(Comn-SR V-1, Item No -13.33.4) Fourth floor

86

383

32951.76

... More
code407 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work(Comn-SR V-1, Item No -13.33) 40 mm nominal OD Pipes(Comn-SR V-1, Item No -13.33.5) Ground floor

72

491

35374.32

... More
code408 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work(Comn-SR V-1, Item No -13.33) 50 mm nominal OD Pipes(Comn-SR V-1, Item No -13.33.6) Ground floor

120

742

89115.6

... More
code409 - Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete: (Comn-SR V-1, Item No -13.5) 20mm nominal bore (Comn-SR V-1, 13.5.2)

10

323

3234.2

... More
code410 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :(Comn-SR V-1, Item No -13.4) 25mm nominal bore (Comn-SR V-1, 13.4.1)

8

565

4523.76

... More
code411 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :(Comn-SR V-1, Item No -13.4) 32mm nominal bore (Comn-SR V-1, 13.4.2)

8

615

4927.52

... More
code412 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :(Comn-SR V-1, Item No -13.4) 40mm nominal bore (Comn-SR V-1, 13.4.3)

10

723

7230.6

... More
code413 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :(Comn-SR V-1, Item No -13.4) 50mm nominal bore (Comn-SR V-1, 13.4.4)

10

880

8806.5

... More
code414 - Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.(Comn-SR V-1, Item No -13.34)

5000

9

46350

... More
code415 - Supplying & fixing suction Y'/ pot stainer with MS flange of suitable length fabricated from 16 gauge brass sheet with 3mm slots. 50 mm dia (MR) Near OHT

2

4334

8668

... More
code416 - Supplying , fixing, testing and commissioning of PVC welded rain water head / khurras dome type grating with puddle flange to fix head in RCC slab specially fabricated from minimum 4mm thick PVC sheet, including removable heavy duty PVC grating of 50 x 3 mm thick PVC flats (Round or Square) as per approved design The quoted rate shall include for necessary grouting the khurras base with approved sealant complete all as shown in the drawing and as specified. 150 x 150mm PVC Grating

10

830

8300

... More
code417 - E. EXTERNAL SEWERAGE SYSTEM & PUMPS Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:(Comn-SR V-5,Item No -10.1) PVC pipes 75 mm dia., 6 kg/sqcm & class 3 (Comn-SR V-5, Item No -10.1.5) Ground Floor

113

226

25605.8

... More
code418 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:(Comn-SR V-5,Item No -10.1) PVC pipes 75 mm dia., 6 kg/sqcm & class 3 (Comn-SR V-5, Item No -10.1.5) First floor

60

226

13596

... More
code419 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:(Comn-SR V-5,Item No -10.1) PVC pipes 75 mm dia., 6 kg/sqcm & class 3 (Comn-SR V-5, Item No -10.1.5) Second floor

52

226

11783.2

... More
code420 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:(Comn-SR V-5,Item No -10.1) PVC pipes 75 mm dia., 6 kg/sqcm & class 3 (Comn-SR V-5, Item No -10.1.5) Third floor

68

226

15408.8

... More
code421 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:(Comn-SR V-5,Item No -10.1) PVC pipes 75 mm dia., 6 kg/sqcm & class 3 (Comn-SR V-5, Item No -10.1.5) Fourth floor

68

226

15408.8

... More
code422 - Supplying of special moulded variety PVC couplers as per IS 7834/1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc. complete.(Comn-SR V-5, Item No -10.8) 75mm dia PVC couplers (Comn-SR V-5, Item No -10.8.6) Ground fFloor

15

69

1035.15

... More
code423 - Supplying of special moulded variety PVC couplers as per IS 7834/1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc. complete.(Comn-SR V-5, Item No -10.8) 75mm dia PVC couplers (Comn-SR V-5, Item No -10.8.6) First floor

10

69

690.1

... More
code424 - Supplying of special moulded variety PVC couplers as per IS 7834/1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc. complete.(Comn-SR V-5, Item No -10.8) 75mm dia PVC couplers (Comn-SR V-5, Item No -10.8.6) Second floor

10

69

690.1

... More
code425 - Supplying of special moulded variety PVC couplers as per IS 7834/1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc. complete.(Comn-SR V-5, Item No -10.8) 75mm dia PVC couplers (Comn-SR V-5, Item No -10.8.6) Third floor

10

69

690.1

... More
code426 - Supplying of special moulded variety PVC couplers as per IS 7834/1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc. complete.(Comn-SR V-5, Item No -10.8) 75mm dia PVC couplers (Comn-SR V-5, Item No -10.8.6) Fourth floor

10

69

690.1

... More
code427 - Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.9) 75mm dia PVC Elbows (Comn-SR V-5, Item No -10.9.6) Ground Floor

15

197

2966.4

... More
code428 - Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.9) 75mm dia PVC Elbows (Comn-SR V-5, Item No -10.9.6) First floor

10

197

1977.6

... More
code429 - Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.9) 75mm dia PVC Elbows (Comn-SR V-5, Item No -10.9.6) Second floor

10

197

1977.6

... More
code430 - Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.9) 75mm dia PVC Elbows (Comn-SR V-5, Item No -10.9.6) Third floor

10

197

1977.6

... More
code431 - Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.9) 75mm dia PVC Elbows (Comn-SR V-5, Item No -10.9.6) Fourth floor

10

197

1977.6

... More
code432 - Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.10) 75mm dia PVC Tee (Comn-SR V-5, Item No -10.10.6) Ground Floor

15

120

1807.65

... More
code433 - Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.10) 75mm dia PVC Tee (Comn-SR V-5, Item No -10.10.6) First floor

10

120

1205.1

... More
code434 - Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.10) 75mm dia PVC Tee (Comn-SR V-5, Item No -10.10.6) Second floor

10

120

1205.1

... More
code435 - Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.10) 75mm dia PVC Tee (Comn-SR V-5, Item No -10.10.6) Third floor

10

120

1205.1

... More
code436 - Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.10) 75mm dia PVC Tee (Comn-SR V-5, Item No -10.10.6) Fourth floor

10

120

1205.1

... More
code437 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:(Comn-SR V-5,Item No -10.1) PVC pipes 110 mm dia., 6 kg/sqcm & class 3 (Comn-SR V-5, Item No -10.1.7) Ground Floor

130

423

55032.9

... More
code438 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:(Comn-SR V-5,Item No -10.1) PVC pipes 110 mm dia., 6 kg/sqcm & class 3 (Comn-SR V-5, Item No -10.1.7) First floor

75

423

31749.75

... More
code439 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:(Comn-SR V-5,Item No -10.1) PVC pipes 110 mm dia., 6 kg/sqcm & class 3 (Comn-SR V-5, Item No -10.1.7) Second floor

75

423

31749.75

... More
code440 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:(Comn-SR V-5,Item No -10.1) PVC pipes 110 mm dia., 6 kg/sqcm & class 3 (Comn-SR V-5, Item No -10.1.7) Third floor

75

423

31749.75

... More
code441 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:(Comn-SR V-5,Item No -10.1) PVC pipes 110 mm dia., 6 kg/sqcm & class 3 (Comn-SR V-5, Item No -10.1.7) Fourth floor

75

423

31749.75

... More
code442 - Supplying of special moulded variety PVC couplers as per IS 7834/1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc. complete.(Comn-SR V-5,Item No -10.8) 110mm dia PVC Couplers (Comn-SR V-5, Item No -10.8.8) Ground Floor

10

176

1761.3

... More
code443 - Supplying of special moulded variety PVC couplers as per IS 7834/1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc. complete.(Comn-SR V-5,Item No -10.8) 110mm dia PVC Couplers (Comn-SR V-5, Item No -10.8.8) First floor

10

176

1761.3

... More
code444 - Supplying of special moulded variety PVC couplers as per IS 7834/1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc. complete.(Comn-SR V-5,Item No -10.8) 110mm dia PVC Couplers (Comn-SR V-5, Item No -10.8.8) Second floor

10

176

1761.3

... More
code445 - Supplying of special moulded variety PVC couplers as per IS 7834/1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc. complete.(Comn-SR V-5,Item No -10.8) 110mm dia PVC Couplers (Comn-SR V-5, Item No -10.8.8) Third floor

10

176

1761.3

... More
code446 - Supplying of special moulded variety PVC couplers as per IS 7834/1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc. complete.(Comn-SR V-5,Item No -10.8) 110mm dia PVC Couplers (Comn-SR V-5, Item No -10.8.8) Fourth floor

10

176

1761.3

... More
code447 - Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.9) 110mm dia PVC Elbows (Comn-SR V-5, Item No -10.9.8) Ground Floor

8

311

2488.48

... More
code448 - Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.9) 110mm dia PVC Elbows (Comn-SR V-5, Item No -10.9.8) First floor

8

311

2488.48

... More
code449 - Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.9) 110mm dia PVC Elbows (Comn-SR V-5, Item No -10.9.8) Second floor

8

311

2488.48

... More
code450 - Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.9) 110mm dia PVC Elbows (Comn-SR V-5, Item No -10.9.8) Third floor

8

311

2488.48

... More
code451 - Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.9) 110mm dia PVC Elbows (Comn-SR V-5, Item No -10.9.8) Fourth floor

8

311

2488.48

... More
code452 - Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.10) 110mm dia PVC Tee (Comn-SR V-5, Item No -10.10.8) Ground Floor

8

258

2068.24

... More
code453 - Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.10) 110mm dia PVC Tee (Comn-SR V-5, Item No -10.10.8) First floor

8

258

2068.24

... More
code454 - Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.10) 110mm dia PVC Tee (Comn-SR V-5, Item No -10.10.8) Second floor

8

258

2068.24

... More
code455 - Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.10) 110mm dia PVC Tee (Comn-SR V-5, Item No -10.10.8) Third floor

8

258

2068.24

... More
code456 - Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.10) 110mm dia PVC Tee (Comn-SR V-5, Item No -10.10.8) Fourth floor

8

258

2068.24

... More
code457 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:(Comn-SR V-5,Item No -10.1) PVC pipes 160 mm dia., 6 kg/sqcm & class 3 (Comn-SR V-5, Item No -10.1.9

230

636

146404.2

... More
code458 - Supplying of special moulded variety PVC couplers as per IS 7834/1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc. complete.(Comn-SR V-5,Item No -10.8) 160mm dia PVC Couplers (Comn-SR V-5, Item No -10.8.10)

20

345

6901

... More
code459 - Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.9) 160mm dia PVC Elbows (Comn-SR V-5, Item No -10.9.10) Ground Floor

15

485

7276.95

... More
code460 - Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.(Comn-SR V-5,Item No -10.10) 160 mm dia PVC Tee (Comn-SR V-5, Item No -10.10.10) Ground Floor

15

479

7199.7

... More
code461 - Constructing brick masonry chamber of internal dimension 300x230mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. (Comn-SR V-5,Item No - 16.12)

9

2856

25705.71

... More
code462 - Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. (Comn-SR V-5,Item No - 16.9)

15

5617

84264.3

... More
code463 - Providing and constructing "WIRE CUT BRICK MACHINEHOLE CHAMBERS" using Portland/Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber. Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Providing and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Providing and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de-watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm dia: Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.3 M depth & SFRC cover & frame. .(Comn-SR V-5,Item No -16.15.4)

2

35729

71459.34

... More
code464 - Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling,available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.In all kinds of soils. Depth upto 1.50m m3 (Comn-SR V-1, Item No -1.6.1)

244.35

498

121813.362

... More
code465 - Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications.(Comn-SR V-1,Item No -1.10) Refilling qty :

244.35

164

40268.88

... More
code466 - Providing and fixing gun metal non- return valve of approved quality (screwed end) 40 mm nominal bore(Comn-SR V-2,Item No -13.6.3.2)

2

1261

2523.5

... More
code467 - Providing and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete .(Comn-SR V-5,Item No -7.5.1) For DI/CI puddle flanges of 80mm dia.

2

1627

3254.8

... More
code468 - Supplying, Intallation, testing and conmissioning of Solar Hot water Heater comprising of solar flat plat collector (FPC) of size 2120 x104 x100mm and stainless steel hot water storage tank with stainless steel Heat exchanges absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity with electrical back up arrangement excluding inlet and outlet pipes. SS model with 100mm thick of 48kg/m3 density rock wool insulation with 22WG Aluminium cladding. '300 Ltrs Capacity. (ELE SR 2-23-24)(7.3.3) Terrace

5

74955

374775.05

... More
code469 - PART - A:- Internal electrical work till Main Panel Open Conduit System Supplying heavy gauge PVC conduit pipe ....... dia ....... m thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws(2/1.2.2) 25mm dia 2mm thick

2500

80

200850

... More
code470 - 32mm dia 2.5mm thick(2/1.2.3)

650

106

68958.5

... More
code471 - Supplying and fixing PVC/metal conduit accessories.(2/1.5.2)deep junction box 25mm junction box

350

57

20188

... More
code472 - 32 mm deep Junction box (2/1.5.3)

150

62

9424.5

... More
code473 - Supplying and flush mounting powder coated metal / galvanised metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (8/3.4.4)6Way

175

226

39655

... More
code474 - Supplying and flush mounting powder coated metal / galvanised metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (8/3.4.6)10-12Way

15

328

4928.55

... More
code475 - Supplying and flush mounting powder coated metal / galvanised metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (8/3.4.8)16-18Way

10

417

4171.5

... More
code476 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.(8/3.5.4)6 -Moudule

175

241

42178.5

... More
code477 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.(8/3.5.6)10-12Moudule

15

354

5314.8

... More
code478 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.(8/3.5.8)16-18Moudule

10

470

4707.1

... More
code479 - Supplying and fixing of modular switch & onnected accessorieson existing modular switch plate as per IS 3854 and IS 1293. (8/3.6.1) 6Amps one way.

1055

105

110838.3

... More
code480 - Supplying and fixing of modular switch & onnected accessorieson existing modular switch plate as per IS 3854 and IS 1293 (8/3.6.3)6A Three Way socket

375

176

66048.75

... More
code481 - Supplying and fixing of modular switch & onnected accessorieson existing modular switch plate as per IS 3854 and IS 1293 (8/3.6.4) Stepped Fan Regulator Two Module

14

367

5147.94

... More
code482 - Supplying and fixing of modular switch & onnected accessorieson existing modular switch plate as per IS 3854 and IS 1293 (8/3.6.9) 32A DP Switch

60

335

20146.8

... More
code483 - Supplying and fixing of modular switch & onnected accessorieson existing modular switch plate as per IS 3854 and IS 1293 (8/3.6.10) 6/16A Universal Socket

60

243

14584.8

... More
code484 - Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 1100V Grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2x1.5 Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose lenght in a wood/PVC round block. complete for each outlet.(5/2.21) short point above 3Mtr from tapping point to out let via switch box

450

277

124681.5

... More
code485 - Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 1100V Grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2x1.5 Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose lenght in a wood/PVC round block. complete for each outlet.(5/2.2.2) medium point above 3Mtr up to 6Mtr from tapping point to out let via switch box

400

390

156148

... More
code486 - Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 1100V Grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2x1.5 Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose lenght in a wood/PVC round block. complete for each outlet.(5/2.2.3) Long point above 6Mtr up to 10Mtr from tapping point to out let via switch box

726

571

415017.9

... More
code487 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments (5/2.3.1) 1 mm2

4500

19

88065

... More
code488 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments (5/2.3.2) 1.5 mm2

13512

26

361851.36

... More
code489 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments (5/2.3.3) 2.5 mm2

5500

43

237930

... More
code490 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments . (5/2.3.4)4 mm2

1250

64

81112.5

... More
code491 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments . (5/2.3.5)6 mm2

350

89

31363.5

... More
code492 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' cure, indicator ON/OFF, energy cross-3 with Short circuit breaking cappacity of 10K and complete wiring as required. Confirming to IEC 60898. (17/5.18.4)6-32 Amps DP

90

761

68505.3

... More
code493 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' cure, indicator ON/OFF, energy cross-3 with Short circuit breaking cappacity of 10K and complete wiring as required. Confirming to IEC 60898. (17/5.18.9)50-63 Amps TPN

12

3180

38167.68

... More
code494 - Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V up to 300mA sensitivity on existing wood/panel board. 32-40 Amps 2 pole (18/5.20.2)

15

2731

40973.4

... More
code495 - Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.( 18/5.19.11 )III- Double Door 4Way TP &N

6

4159

24954.84

... More
code496 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short- icrcuit/Over Load. ForMicroprocessor MCCBS Facility for segregating Priority andNon-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between frontcover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all thepoles simultaneously and they shall have a single mechanism. (17/5.15.9) FOUR POLE 160Amps 25kA

1

8741

8741.61

... More
code497 - Supplying and fixing of Shunt trip suitable for MCCB.CBCT (12/5.16)

2

1754

3508.18

... More
code498 - Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.(18/5.21)

2

9532

19065.3

... More
code499 - Fabricating supplying and mounting MS box made out …SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.18SWG(20/5.42.3)

150000

-

58500

... More
code500 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 50x50x6mm(20/5.41.2)

10

406

4068.5

... More
code501 - Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.100Amps 4x30x6mm Aluminium Strips (15/5.40.1)

5

2538

12694.75

... More
code502 - Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. (Water Supply 164/45/ P430A)

6

3615

21691.8

... More
code503 - Supplying of recess mounting non integral type ...'LED ...... W luminaire comprising of pressure decast/extruded aluminum housing, with spring loaded fase ceiling clamps, Power LEDs with CCT 6500 degree K, CRIGreater than 70%. efficasy Greater than100 lumen per watt, 120degree beam spread, lifeGreater than 25000 burning hours and Complaince to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF Greater than 0.95, power loss should Less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, , THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI acredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 1x4' 34 -36w RC380B-LED36S(45/11.6.5)

10

6074

60749.4

... More
code504 - Supplying of ....... feet - LED PVC Square Batten ..W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @ 50Hz & Power factor Greater than0.9 along with CE approved. 5 years Warranty against any manufacturing defect working under standard electrical condition ( 43/11.3.2)LED light fitting 1 x 4' - 20/22 W

525

710

373117.5

... More
code505 - Supplying wall/ceiling mounting fan suitable to operate at singlephase 230v AC. Supply. 400 mm Sweep ( 30/6.5.2)

165

3308

545879.4

... More
code506 - Fixing all types and all capacities of fluorescent /False ceiling/spot light /CFL/LED fittings indoor on the wall/ ceiling/rafters/girders using 23/0.0076' twin twisted PVC insulated wires, required Nos of round blocks and clamps. (13.7.1)On wall / ceiling /Rafter / Girders

525

125

65971.5

... More
code507 - Fixing a Ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook wisth fan regulator to the existing board together wisth wupplying and fixing 5amps. Ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. (57/13.10)

165

176

29061.45

... More
code508 - Supplying And Fixing Metal Fan Box with Round Hook.(1/1.13)

14

120

1687.14

... More
code509 - Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete.(upto 50 mm conduit in brick wall) ( 1/1.71)

1500

29

44805

... More
code510 - LED square or round down light 10-12W

520

911

474006

... More
code511 - Fixing all types and all capacities of fluorescent /False ceiling/spot light /CFL/LED fittings indoor on the wall/ ceiling/rafters/girders using 23/0.0076' twin twisted PVC insulated wires, required Nos of round blocks and clamps. (13.7.1)On wall / ceiling /Rafter / Girders

520

125

65343.2

... More
code512 - 240SQMM3.5 C(30GI Strips4x0.8mm) 32.18

350

887

310751

... More
code513 - Design, supplying, erecting testing and commissioning of -passenger/ Bed-cum-passenger hospital lift with speed of 1mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 V 3 phase 50 cycles AC supply, powder coated / Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED car illumination, emergency light, intercom and fan as desired by the user, central opening / side opening door with or without attendant operation, 7 segment display buttons, call register indicator, fireman drive, SS handrails inside car, full length infrared curtain in car door, automatic rescue device with batteries, voice announcing in regional / international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc.,. (item No - 14.4.2 PWD Ele SR 2023-2024) With Out Machine Room-SS Finish ( 8-Passgenrs 5 - Stops )

1

1640458

1640458.22

... More
code514 - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. (UNI-SR V-1, Item No - 1.14.1 ) For main Sump

107.17

105

11259.2802

... More
code515 - Providing and laying in position plain cement concrete for levelling course Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) (UNI-SR V-1, Item No - 2.1.2 )

6.2

5833

36170.304

... More
code516 - Providing and laying in position Reinforced cement concrete M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) (UNI-SR V-1, Item No - 2.2.2.1 )

16.57

7048

116790.1653

... More
code517 - Providing and laying in position Reinforced cement concrete M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) (UNI-SR V-1, Item No - 2.2.2.1 ) Add shuttering, cost-8%

16.57

563

9343.1602

... More
code518 - Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). (UNI-SR V-1, Item No - 2.3.2 ) Side walls

10.72

6674

71549.568

... More
code519 - Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). (UNI-SR V-1, Item No - 2.3.2 ) shuttering, cost-10%

10.72

667

7154.528

... More
code520 - Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). (UNI-SR V-1, Item No - 2.3.2 ) Top Slab

6.89

6674

45986.616

... More
code521 - Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). (UNI-SR V-1, Item No - 2.3.2 ) Top Slab Add shuttering, cost-50%

6.89

3337

22993.308

... More
code522 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (UNI-SR V-1, Item No - 1.9 )

20.48

273

5611.1104

... More
code523 - Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)

4.44

92140

409104.7524

... More
code524 - Providing and laying water proofing treatment to the Retaining wall area with PU Elastomeric Single component liquid applied, cold applied, moisture cured high tensile elastomeric PU waterproofing membrane having elongation of more than 400% and having solid content of above 90% @ 1.6kg per m2 in 2 coats to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g/ m2. The cost is inclusive of surface preparation, crack filling, repair of loose mortar etc. completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. (UNI-SR V-3, Item No - 9.3 )

97.09

914

88802.3976

... More
code525 - Providing and fixing MS ladder between landings, 45 cms wide using angle iron of specified sizes, 20mm MS bars at 25 cms. centre to centre, with necessary supports of same angle iron etc. as directed, including hand railing on both sides with 25mm dia. GI pipes with angle iron props at 2 mtrs. intervals and 0.5M heigh, including fixing in ground with CC 1:2:4 and two coats of anticorrosive bituminous paint etc. with all lead and lifts etc. complete with: MS angle of 65 x 65 x 10mm (Comn-SR V-5, Item No -11.2, Page No-111)

1.79

4945

8851.6037

... More
code526 - Providing and fixing MS inspection door of size 60 cms x 60 cms, including MS frame made of 50x50x6mm angle, shutters made of 3mm thick MS sheets, with hinges, locking arrangements at top etc. including painting with anticorrosive approved paint etc. complete including all lead and lifts etc. (Comn-SR V-5, Item No -13, Page No-111)

1

2204

2204.2

... More
code527 - Providing, supplying to work site,Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications,with testing of as per instructions of engineer incharge of work and latest amendments. 1.00 HP/0.75KW - 7 STG ( WS & UGD Comm SR V-5, Chapter-15, Item No - 6.1 )

1

13717

13717.54

... More
code528 - Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. etc. complete.(P.No.140, I.No 12.4 , Vol 5 of PW,P & IWTD S.R 2022-23)

1

5446

5446.64

... More
code529 - Sinking of Borewell of 165mm dia clear, using superfast Hydraulic rig of capacity 250 PSIG and above 900 CFM and above in all strata including over burden upto 20m fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of Rig & supporting vehicle, crew charges & cost of consumables etc., complete including yield testing and the final depth with a minimum working compressor for one hour (excluding cost of casting pipes, collars and cap etc.) As per amendment ,2nd corrigendum 7/06/22. (P.No.139, I.No 12.1.1 to 12.1.7. Vol 5 of PW,P & IWTD S.R 2022-23) 0.00 to 50.00 mtrs 1.1 O010A

50

381

19055

... More
code530 - Sinking of Borewell of 165mm dia clear, using superfast Hydraulic rig of capacity 250 PSIG and above 900 CFM and above in all strata including over burden upto 20m fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of Rig & supporting vehicle, crew charges & cost of consumables etc., complete including yield testing and the final depth with a minimum working compressor for one hour (excluding cost of casting pipes, collars and cap etc.) As per amendment ,2nd corrigendum 7/06/22. (P.No.139, I.No 12.1.1 to 12.1.7. Vol 5 of PW,P & IWTD S.R 2022-23) 50.00 to 100.00mtrs 1.2 O010B

50

477

23896

... More
code531 - Sinking of Borewell of 165mm dia clear, using superfast Hydraulic rig of capacity 250 PSIG and above 900 CFM and above in all strata including over burden upto 20m fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of Rig & supporting vehicle, crew charges & cost of consumables etc., complete including yield testing and the final depth with a minimum working compressor for one hour (excluding cost of casting pipes, collars and cap etc.) As per amendment ,2nd corrigendum 7/06/22. (P.No.139, I.No 12.1.1 to 12.1.7. Vol 5 of PW,P & IWTD S.R 2022-23) 100.00 to 150.00mtrs 1.3 O010C

50

507

25389.5

... More
code532 - Sinking of Borewell of 165mm dia clear, using superfast Hydraulic rig of capacity 250 PSIG and above 900 CFM and above in all strata including over burden upto 20m fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of Rig & supporting vehicle, crew charges & cost of consumables etc., complete including yield testing and the final depth with a minimum working compressor for one hour (excluding cost of casting pipes, collars and cap etc.) As per amendment ,2nd corrigendum 7/06/22. (P.No.139, I.No 12.1.1 to 12.1.7. Vol 5 of PW,P & IWTD S.R 2022-23) 150.00 to 200.00mtrs 1.4 O010D

50

589

29458

... More
code533 - Sinking of Borewell of 165mm dia clear, using superfast Hydraulic rig of capacity 250 PSIG and above 900 CFM and above in all strata including over burden upto 20m fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of Rig & supporting vehicle, crew charges & cost of consumables etc., complete including yield testing and the final depth with a minimum working compressor for one hour (excluding cost of casting pipes, collars and cap etc.) As per amendment ,2nd corrigendum 7/06/22. (P.No.139, I.No 12.1.1 to 12.1.7. Vol 5 of PW,P & IWTD S.R 2022-23) 200 to 250.00mtrs 1.5 O010E

50

691

34556.5

... More
code534 - Sinking of Borewell of 165mm dia clear, using superfast Hydraulic rig of capacity 250 PSIG and above 900 CFM and above in all strata including over burden upto 20m fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of Rig & supporting vehicle, crew charges & cost of consumables etc., complete including yield testing and the final depth with a minimum working compressor for one hour (excluding cost of casting pipes, collars and cap etc.) As per amendment ,2nd corrigendum 7/06/22. (P.No.139, I.No 12.1.1 to 12.1.7. Vol 5 of PW,P & IWTD S.R 2022-23) 250 to 300.00mtrs 1.6 O010F

10

762

7622

... More
code535 - Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socketconforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. (P.No.143, I.No 12.32. Vol 5 of PW,P & IWTD S.R 2022-23)

30

1990

59729.7

... More
code536 - Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge. (P.No.143, I.No 12.33. Vol 5 of PW,P & IWTD S.R 2022-23)

1

168

168.92

... More
code537 - Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments. (P.No.143, I.No 12.33. Vol 5 of PW,P & IWTD S.R 2022-23)

5

154

772.5

... More
code538 - Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For -For -7.5 HP - 90 LPM @ 165 m = 16 STG Outlet Dia - 2.00”. (Page No. : 152, Item No.13.15.7 KWS & DB S R Vol-5 2022-23)

1

42034

42034.3

... More
code539 - Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1X3X6 Sqm. (Page No. : 154, Item No.13.22.4, KWS & DB S R Vol-5 2022-23)

230

190

43826.5

... More
code540 - Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. (Page No. : 156, Item No.13.32 KWS & DB S R Vol-5 2022-23)

1

6695

6695

... More
code541 - Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete. 50 mm dia (PWD SR 2022-23 , vol-2, P119, I no 13.10.6)

2

709

1419.34

... More
code542 - Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL Direct Online Starter 2) S-D- Star Delta Starter 6 to 15 HP pumps. (Page No. : 155, Item No.13.23.2 , KWS & DB S R Vol-5 2022-23)

2

16377

32754

... More
code543 - Erection of single phase preventer / ammeters / including fixing selector switch / voltmeter / current operated earth leakage circuit breakers / voltage operated circuit breaker / above 100A fuse channel set (3 Nos) HRC fuses above 100A (3 Nos.) / Digital ammeter/digital volt meter/set of 3 indicating lamps /MCB / Relays /A-V selector switches including wiring using suitable capacity wires, bolts, nuts,screws. (PWD Ele SR 2022-23 Pg no.46 Sl no.13.16)

1

203

203.94

... More
code544 - Fabricating, supplying and mounting MS box made out of 18 SWG suitable for floor/ wall mounting, fully weather proof with provision for better heat dissipation provided with hinged front cover with with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7 Tanks Treatment wit powder coat ed paint & finaly finished with approved colour & etc. (PWD Ele SR 2-23-24 Pg no.20, Sl no.5.42.3)

30000

-

11700

... More
code545 - Supplying and fixing miniature circuit breakers/isolators on existing MCB distribution boards using necessary fixing materials and wiring complete as required - 40 to 63 amps triple pole. ( PWD Ele SR 2-23-24 P-47, It No.6.16.2)

1

697

697.31

... More
code546 - Supplying and running of GI copper strip or grounding connection using necessary fixing material required 600x600x3mm GI plate. (PWD Ele SR 2-23-24 (P-54, Sl no.12.58.6)

1

901

901.25

... More
code547 - Supplying and fixing Porcelain fuse channel with cut out on the existing wooden /panel using necessary nuts bolts and washer etc., complete. 16 A. (P-No.10 , I.No.5.7.1 KPWD Ele SR 2022-23),

3

161

485.13

... More
code548 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 50 mm nominal bore. (P.No.115, I.No.13.4.4 of KPWD Elec S.R 2022-23)

1

880

880.65

... More
code549 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1,Armouring strip thickness and resistivity as per IS-3975 , 4 core 16sqmm. ( Ele SR 22-23 Pg no. sl no. 32.05)

30

188

5668.5

... More
code550 - Labour charges for Laying of 1.1 KV Class UG cable 6 Sqmm to 16 sqmm

30

12

367.2

... More
code551 - Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating in Hard soil etc., complete. complete as per specifications and direction of the Engineer-in-Charge. (As per Civil SR KSRB I-1.17.1, P-10, vol -1)

30

269

8095.8

... More
code552 - Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) Medium Duty GI pipe of 65mm dia. Vol-5 SR(2021-22), P-142, I- N010G

30

740

22217.1

... More
code553 - Supplying and fixing LT cast iron pot heads suitable for 1.1 KV class UG cable filled wiith necessary bitumen / insulating compound complete. With terminals, clamps, bolts nuts and washers etc.complete for 16 Sqmm as per specification. (KPWD Ele SR Pg no.62 sl no.7.13.2)

1

278

278.1

... More
code554 - Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m. (P.No.6, I.No.1.6.1 of KPWD S.R 2022-23)

74.21

498

36995.1692

... More
code555 - Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. 6 Kg/m2: 63mm(weight of pipe -0.662 kg) (P.No.134, I.No.M010C of KPWD S.R 2022-23)

165

138

22773.3

... More
code556 - Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications. (P.No.7, I.No.1.10 of KPWD S.R 2022-23)

55.65

164

9171.12



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.