Karnataka Housing Board Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Karnataka Housing Board - KHB Tender

Civil And Construction
Building Construction
Opening Date9 Jul 2024
Closing Date18 Jul 2024
Tender Amount₹ 3,12,14,366.89 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - Providing and Filling in foundation with granite/trap broken [metal100mm and down size with approved M-Sand including hand packing, ramming, watering including the cost of all materials and labour with all lead and lift complete as per specifications.

20.57

2762

56823.8022

... More
code05 - Providing and laying in position plain cement concrete for leveling course for all works in the foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of [steel reinforcement & formwork shall be paid separately)-Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates

20.57

6008

123603.8958

... More
code06 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. Rate including cost of Formwork, Centering & Scaffolding. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Footings

44.62

7048

314489.3454

... More
code07 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. Rate including cost of Formwork, Centering & Scaffolding. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Plinth Beam

1.82

11094

20191.6988

... More
code08 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. Rate including cost of Formwork, Centering & Scaffolding. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates GROUND FLOOR PLINTH BEAM

11.07

10572

117036.9108

... More
code09 - Filling available excavated earth (excluding rock) in trenches plinths, sides of foundations, and other similar works, etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

153.47

445

68446.0853

... More
code10 - Providing Size Stone masonry with a hard stone in foundation & plinth with Cement mortar 1:6 (1 cement: 6 coarse sand)

9.36

6580

61595.0712

... More
code11 - Providing and laying in position plain cement concrete for leveling course for all works in the foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately, Rate including cost of Formwork, Centering & Scaffolding)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates.

5.21

6403

33362.2871

... More
code12 - Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For Column

3.59

11982

43015.7031

... More
code13 - Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For Column STAIRCASE COLUMN GROUND FLOOR TO FIRST FLOOR

1.64

12101

19847.1324

... More
code14 - Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. FIRST FLOOR TO TERRACE FLOOR ( SUPER STR )

9.93

12101

120171.9663

... More
code15 - Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. SECOND FLOOR TO TERRACE FLOOR

23.43

12221

286355.1339

... More
code16 - Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation [works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Beams

5.24

11277

59092.8424

... More
code17 - Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation [works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Beams For first floor

5.25

11390

59797.71

... More
code18 - Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation [works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Beams for Bridge

5.8

11277

65408.108

... More
code19 - Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation [works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Beams For terrace floor

21.27

11502

244664.7687

... More
code20 - Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation [works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Block - C For Beams For terrace floor

61.7

11502

709723.377

... More
code21 - Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, [Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For Lintle GROUND FLOOR - Staircase wall (BLOCK B)

0.05

11277

563.863

... More
code22 - Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, [Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For Lintle GROUND FLOOR - Staircase wall (BLOCK B)

0.84

11390

9567.6336

... More
code23 - Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, [Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For Lintle GROUND FLOOR - Staircase wall (BLOCK B) TERRACE FLOOR (BLOCK B)

0.1

11502

1150.281

... More
code24 - Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, [Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For Lintle GROUND FLOOR - Toilet (BLOCK C)

0.81

11277

9134.5806

... More
code25 - Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, [Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For Lintle FIRST FLOOR - Toilet (BLOCK C)

0.81

11390

9225.9324

... More
code26 - Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, [Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For Lintle

3.63

11390

41345.8452

... More
code27 - Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate Cill Concrete GROUND FLOOR - Staircase wall (BLOCK B)

0.05

11277

563.863

... More
code28 - Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate Cill Concrete FIRST FLOOR (BLOCK B)

0.65

11390

7403.526

... More
code29 - Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate Cill Concrete TERRACE FLOOR (BLOCK B)

0.05

11502

575.1405

... More
code30 - Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate Cill Concrete GROUND FLOOR - Toilet (BLOCK C)

0.41

11277

4623.6766

... More
code31 - Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate Cill Concrete FIRST FLOOR - Toilet (BLOCK C)

0.41

11390

4669.9164

... More
code32 - Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate Cill Concrete SECOND FLOOR - Classrooms (BLOCK C)

2.58

11502

29677.2498

... More
code33 - Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate GROUND FLOOR - Staircase wall (BLOCK B)

0.2

7048

1409.658

... More
code34 - Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate FIRST FLOOR (BLOCK B)

1.82

7118

12956.1614

... More
code35 - Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate TERRACE FLOOR (BLOCK B)

0.2

7189

1437.852

... More
code36 - Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate SECOND FLOOR - Classrooms (BLOCK C)

7.49

7189

53847.5574

... More
code37 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density of more than 1800kg/Cum and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - 1) 2005 and constructed with CM 1:4 as per IS 2572:2005 including the cost of all materials, labor, scaffolding, and curing, usage charges of machinery, etc complete as per specifications. Ground floor

48.14

1349

64955.302

... More
code38 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density of more than 1800kg/Cum and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - 1) 2005 and constructed with CM 1:4 as per IS 2572:2005 including the cost of all materials, labor, scaffolding, and curing, usage charges of machinery, etc complete as per specifications. Total first floor

393.21

1362

535862.6559

... More
code39 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density of more than 1800kg/Cum and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - 1) 2005 and constructed with CM 1:4 as per IS 2572:2005 including the cost of all materials, labor, scaffolding, and curing, usage charges of machinery, etc complete as per specifications. Total Terrace floor

162.92

1362

222025.7468

... More
code40 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density of more than 1800kg/Cum and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - 1) 2005 and constructed with CM 1:4 as per IS 2572:2005 including the cost of all materials, labor, scaffolding, and curing, usage charges of machinery, etc complete as per specifications. Ground Floor Total Qty

199.5348

1349

269232.30564

... More
code41 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density of more than 1800kg/Cum and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - 1) 2005 and constructed with CM 1:4 as per IS 2572:2005 including the cost of all materials, labor, scaffolding, and curing, usage charges of machinery, etc complete as per specifications. First Floor Total Qty

200.59

1362

273362.0461

... More
code42 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density of more than 1800kg/Cum and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - 1) 2005 and constructed with CM 1:4 as per IS 2572:2005 including the cost of all materials, labor, scaffolding, and curing, usage charges of machinery, etc complete as per specifications. Second floor Total Qty

1011.79

1376

1392516.4591

... More
code43 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density of more than 1800kg/Cum and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - 1) 2005 and constructed with CM 1:4 as per IS 2572:2005 including the cost of all materials, labor, scaffolding, and curing, usage charges of machinery, etc complete as per specifications. Parapet Qty

171.5

1389

238347.27

... More
code44 - Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Slab

6.77

10607

71813.9936

... More
code45 - Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. First floor + mumty stair area

9.04

10607

95893.4272

... More
code46 - Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Terrace slab

46.72

10607

495590.8096

... More
code47 - Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Connecting Corridor

4.31

10607

45719.1008

... More
code48 - Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Bath Roof

16.05

10607

170253.264

... More
code49 - Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Terrace slab

109.8

10607

1164723.264

... More
code50 - Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Staircase

6.27

10220

64079.5254

... More
code51 - Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Staircase

6.27

10322

64720.3194

... More
code52 - Providing and laying in position Reinforced cement concrete for all Superstructures of building, Road works, Waterworks, Irrigation works & superstructure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticizers laid in layers, well compacted using needle vibrators. The cost includes all leads & lifts, cost of all materials, quality conforming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars is to be paid separately and Rate inclusive of Formwork, Centering & Scaffolding cost)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Staircase

6.27

10424

65361.1134

... More
code53 - Providing Thermo-Mechanically Treated bars of gradeFe-550Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding, and anchoring to adjacent members wherever necessary complete as per Design including the cost of material, labor, and usage charges complete as per specifications. (The laps and wastages shall not be measured separately)

9.15

92140

843087.4965

... More
code54 - Providing Thermo-Mechanically Treated bars of gradeFe-550Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding, and anchoring to adjacent members wherever necessary complete as per Design including the cost of material, labor, and usage charges complete as per specifications. (The laps and wastages shall not be measured separately) First Floor

13.13

93062

1221905.6356

... More
code55 - Providing Thermo-Mechanically Treated bars of gradeFe-550Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding, and anchoring to adjacent members wherever necessary complete as per Design including the cost of material, labor, and usage charges complete as per specifications. (The laps and wastages shall not be measured separately) Second Floor

31.95

93062

2973334.734

... More
code56 - Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications FIRST FLOOR (BLOCK B)

0.47

102797

48314.7028

... More
code57 - Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications TERRACE FLOOR (BLOCK B)

0.12

103815

12457.8048

... More
code58 - Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications GROUND FLOOR - Toilet (BLOCK C)

1.23

101779

125188.7235

... More
code59 - Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications FIRST FLOOR - Toilet (BLOCK C)

1.23

102797

126440.6052

... More
code60 - Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications SECOND FLOOR - Toilet (BLOCK C)

1.23

103815

127692.4992

... More
code61 - Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications SECOND FLOOR - Classrooms (BLOCK C)

1.62

103815

168180.3648

... More
code62 - Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TO2(Titanium Dioxide) at 6PHR with TE(Thermo Plastic Elastomer) and lead free, gaskets - grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOOR Staircase wall (BLOCK B)

2.7

6936

18727.254

... More
code63 - Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TO2(Titanium Dioxide) at 6PHR with TE(Thermo Plastic Elastomer) and lead free, gaskets - grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) FIRST FLOOR (BLOCK B)

24.3

7005

170230.734

... More
code64 - Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TO2(Titanium Dioxide) at 6PHR with TE(Thermo Plastic Elastomer) and lead free, gaskets - grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) TERRACE FLOOR (BLOCK B)

2.7

7074

19101.798

... More
code65 - Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TO2(Titanium Dioxide) at 6PHR with TE(Thermo Plastic Elastomer) and lead free, gaskets - grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) SECOND FLOOR - Classrooms (BLOCK C)

99.9

7144

713695.59

... More
code66 - Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE ( Thermo Plastic Elastomer) and lead free with gaskets grey color having isolated drainage and reinforced with Galvanized Iron profile through out the ventilator frame. The frame has an overall size of 39mm x 39mm with a Gi reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pinhead glass. The wall thickness of the frame shall be 2mm. Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for [minor T&Ps shall not be made) FIRST FLOOR Corridor (BLOCK B)

3.24

5949

19276.3152

... More
code67 - Providing & fixing of louvered ventilator made out of multi-chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead-free with gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame has an overall size of 39mm x 39mm with a Gl reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pinhead glass. The wall thickness of the frame shall be 2mm. Maximum possible size - 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for [minor T&Ps shall not be made) FIRST FLOOR - Corridor (BLOCK B)

5.88

5890

34636.5516

... More
code68 - Providing & fixing of louvered ventilator made out of multi-chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead-free with gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame has an overall size of 39mm x 39mm with a Gl reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white)will be used on the frame along with plastic parts for fixing the 4 mm pinhead glass. The wall thickness of the frame shall be 2mm. Maximum possible size - 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for [minor T&Ps shall not be made) FIRST FLOOR - Toilet (BLOCK C)

5.88

5949

34982.9424

... More
code69 - Providing & fixing of louvered ventilator made out of multi-chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead-free with gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame has an overall size of 39mm x 39mm with a Gl reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pinhead glass. The wall thickness of the frame shall be 2mm. Maximum possible size - 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for [minor T&Ps shall not be made) SECOND FLOOR - Toilet (BLOCK C)

5.88

6008

35329.2744

... More
code70 - Providing & fixing of louvered ventilator made out of multi-chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead-free with gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame has an overall size of 39mm x 39mm with a Gl reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white)will be used on the frame along with plastic parts for fixing the 4 mm pinhead glass. The wall thickness of the frame shall be 2mm. Maximum possible size - 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for [minor T&Ps shall not be made) SECOND FLOOR - Classrooms (BLOCK C)

2.52

6008

15141.1176

... More
code71 - Providing and fixing flush door shutters made out of solid core block board type, well seasoned, chemically treated hardwood battens and internal frame with minimum 45 mm wide wooden frame around door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I)1991. from manufacturer complete as per spcification.-35 mm thick on both sides commercial FIRST FLOOR (BLOCK B)

14.4

3455

49764.672

... More
code72 - Providing and fixing flush door shutters made out of solid core block board type, well seasoned, chemically treated hardwood battens and internal frame with minimum 45 mm wide wooden frame around door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I)1991. from manufacturer complete as per spcification.-35 mm thick on both sides commercial TERRACE FLOOR (BLOCK B)

3.6

3490

12564.324

... More
code73 - Providing and fixing flush door shutters made out of solid core block board type, well seasoned, chemically treated hardwood battens and internal frame with minimum 45 mm wide wooden frame around door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I)1991. from manufacturer complete as per spcification.-35 mm thick on both sides commercia GROUND FLOOR - Toilet (BLOCK C)

23.57

3421

80648.5262

... More
code74 - Providing and fixing flush door shutters made out of solid core block board type, well seasoned, chemically treated hardwood battens and internal frame with minimum 45 mm wide wooden frame around door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I)1991. from manufacturer complete as per spcification.-35 mm thick on both sides commercia FIRST FLOOR - Toilet (BLOCK C)

23.57

3455

81455.0916

... More
code75 - Providing and fixing flush door shutters made out of solid core block board type, well seasoned, chemically treated hardwood battens and internal frame with minimum 45 mm wide wooden frame around door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I)1991. from manufacturer complete as per spcification.-35 mm thick on both sides commercia SECOND FLOOR - Toilet (BLOCK C)

23.57

3490

82261.4213

... More
code76 - Providing and fixing flush door shutters made out of solid core block board type, well seasoned, chemically treated hardwood battens and internal frame with minimum 45 mm wide wooden frame around door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I)1991. from manufacturer complete as per spcification.-35 mm thick on both sides commercia SECOND FLOOR - Classrooms (BLOCK C)

43.01

3490

150108.7709

... More
code77 - Fixing of the door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of the frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including the cost of materials, and labour charges, complete as per specifications. sl.no-12.51, pg.no-104, volume-2.

59

1046

61742.32

... More
code78 - Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. SL.NO-12.60, PG.NO-105, VOLUME-2.

59

1083

63930.04

... More
code79 - Providing and fixing chromium-plated brass handles of 100/125 mm with necessary screws etc. complete. SL.NO-12.62, PG.NO 105, VOLUME-2.

144

244

35151.84

... More
code80 - Providing and fixing bright finished brass butt hinges with necessary screws etc. complete :100x85x5.5mm. (heavy type)SI.no-12.75.3, pg.no-107,volume-2.

216

211

45608.4

... More
code81 - Providing and fixing MS Hold fasts (SL. No 444, Page NoA-25, Basic Rate Rs. 50.00), volume-2.

354

51

18231

... More
code82 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding

56.7

173

9811.368

... More
code83 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding FIRST FLOOR (BLOCK B)

510.3

174

89185.131

... More
code84 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding TERRACE FLOOR (BLOCK B)

56.7

176

10007.55

... More
code85 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding SECOND FLOOR - Classrooms (BLOCK C)

2097.9

176

370279.35

... More
code86 - Providing 12 mm cement plaster with Cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete. First floor + Mumty Area

64.75

336

21757.295

... More
code87 - Providing 12 mm cement plaster with Cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete. First Floor Roof

358.19

336

120359.0038

... More
code88 - Providing 12 mm cement plaster with Cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete. Back bath roof

115.03

339

39034.2802

... More
code89 - Providing 12 mm cement plaster with Cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete. Second Floor Roof

841.8

339

285656.412

... More
code90 - Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. BLOCK B

1268.95

376

478368.771

... More
code91 - Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. BLOCK C

3327.39

376

1254359.4822

... More
code92 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)- Mixn 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates.

31.15

6403

199469.3365

... More
code93 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)- Mixn 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates.

73.2

6403

468736.932

... More
code94 - Providing and laying cinder concrete in cement 1:15 (1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. SI. No 7.18, Page No23, Volume-2.

23.08

2077

47948.9308

... More
code95 - Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications.

29.73

5487

163153.4832

... More
code96 - Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications. First Floor to TERRACE FLOOR

29.73

5542

164785.0656

... More
code97 - Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications. Second to Terrace Floor

30.91

5597

173021.816

... More
code98 - Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm. BLOCK B

358.19

1191

426654.4366

... More
code99 - Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm. BLOCK C

841.8

1202

1012634.892

... More
code100 - Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. BLOCK C

467.28

1139

532316.0304

... More
code101 - Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 It/10 m2 over and including one coat of Specialprimer applied @ 0.75 Itr /10 m with paint of approved quality to given even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR + MUMTY STAIR AREA

64.75

164

10642.9575

... More
code102 - Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 It/10 m2 over and including one coat of Specialprimer applied @ 0.75 Itr /10 m with paint of approved quality to given even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. First Floor Ceiling - Internal Paint

358.19

164

58875.6903

... More
code103 - Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 It/10 m2 over and including one coat of Specialprimer applied @ 0.75 Itr /10 m with paint of approved quality to given even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Back bath roof

168.53

164

27701.2761

... More
code104 - Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 It/10 m2 over and including one coat of Specialprimer applied @ 0.75 Itr /10 m with paint of approved quality to given even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. First Floor Ceiling - Internal Paint

841.8

164

138366.666

... More
code105 - Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications Two coats applied on walls @ 1.25 It/10 m over and including one coat of Specialprimer applied @ 0.75 Itr /10 m with paint of approved quality to given even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. BLOCK B

1268.95

164

208577.3115

... More
code106 - Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications Two coats applied on walls @ 1.25 It/10 m over and including one coat of Specialprimer applied @ 0.75 Itr /10 mwith paint of approved quality to given even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. BLOCK C

3327.39

164

546923.0943

... More
code107 - Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge. FIRST FLOOR (BLOCK B)

14.4

58

838.944

... More
code108 - Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge.

3.6

58

211.788

... More
code109 - Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge GROUND FLOOR - Toilet (BLOCK C)

23.57

57

1359.5176

... More
code110 - Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge FIRST FLOOR - Toilet (BLOCK C)

23.57

58

1373.1882

... More
code111 - Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge SECOND FLOOR - Toilet (BLOCK C)

23.57

58

1386.6231

... More
code112 - Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge SECOND FLOOR - Classrooms (BLOCK C)

43.01

58

2530.2783

... More
code113 - Polishing on wood work with ready mixed wax polish of approved brand and manufacture: New work to give an even surface including preparing the surface after thorougly cleaning oil, grease dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. BLOCK B

86.4

140

12134.016

... More
code114 - Polishing on wood work with ready mixed wax polish of approved brand and manufacture: New work to give an even surface including preparing the surface after thorougly cleaning oil, grease dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. BLOCK C

545.81

140

76653.5564

... More
code115 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge BLOCK B

93.42

587

54909.4734

... More
code116 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge BLOCK B

93.42

593

55453.1778

... More
code117 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge BLOCK C

93.42

593

55453.1778

... More
code118 - Providing and laying in position cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. BLOCK B

23.36

9701

226622.8352

... More
code119 - Providing and laying in position cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. BLOCK C

58.56

9701

568109.2992

... More
code120 - Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials labour, curing complete as per specifications and as per directions of Engineer-in-charge. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin-Charge. Terrace Floor (BLOCK B

311.47

380

118592.2025

... More
code121 - Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials labour, curing complete as per specifications and as per directions of Engineer-in-charge. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin-Charge. Terrace Floor (BLOCK C

732

380

278709

... More
code122 - Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. Terrace Floor (BLOCK B)

311.47

849

264727.6971

... More
code123 - Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. Terrace Floor (BLOCK C)

1098

849

933223.14

... More
code124 - Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. Bath Area

80.25

849

68206.8825

... More
code125 - Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m, as per drawing and technical specification, including setting out, shorting, barricading, caution lights, including dressing of excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including the cost of labour, tools, usage of machinery and other appurtenances required to complete the work in all kinds of soils Depth upto 3m. Page No. 5, SI. No. 1.14,VOL-1

313.47

105

32933.1582

... More
code126 - Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications

313.47

164

51659.856

... More
code127 - Providing and laying in position cement concrete of mix 1:3:6 with OPC cement @ 220kgs, with 20mm and down size graded granite metal coarse aggregates @0.84cum and fine aggregtes @ 0.56cum, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, plinth and cills, ncluding cost of all materials, labour, HOM of machinery, curing complete as per specifications. Specification No. I.No.2.1.3 vol-1

5.36

6168

33064.0712

... More
code128 - Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 100 mm nominal dia Pipes, VOL-II, I.NO.13.50.9

250

957

239475

... More
code129 - Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm nominal dia Pipes External work VOL-II, I.NO.13.50.10

528

1640

866337.12

... More
code130 - Providing and fixing white vitreous china water closet squatting pan (Indian type) : Orissa pattern W.C. pan of size 580x440 MM I.NO. 14.13.2 VOL.2

5

2400

12004.65

... More
code131 - Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid I.NO :14.3.1, VOL NO.II

40

6156

246252.4

... More
code132 - Providing and fixing white vitreous china clay, flat back or half stall urinal basin of size 580x380x350mm with 5 litres P.V.C automatic flushing cistern, C.I / M.S brackets, standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps C.I dtrap with outlet grating and other couplings in C.P brass, painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete. Specification No. 11-9.1

8

5124

40994

... More
code133 - Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. I.NO.14.23 VOL.1

3

1188

3565.86

... More
code134 - Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps I.NO.14.7.1

30

3174

95233.8

... More
code135 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - 40 mm nominal dia Pipes

30

552

16562.4

... More
code136 - Providing and fixing 100 mm sand cast Iron grating for gully trap. I.NO. 14.29 VOL-2

35

48

1694.35

... More
code137 - Providing and fixing brass bib cock of approved quality 15 mm nominal bore I.NO. 13.2.1 VOL-2

35

195

6849.5

... More
code138 - Providing and fixing brass stop cock of approved quality 15 mm nominal bore

35

307

10778.95

... More
code139 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore

35

565

19791.45

... More
code140 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore I.NO.13.4.2

35

615

21557.9

... More
code141 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal dia Pipes I.NO.13.31.2 VOL-2

1120

249

279171.2

... More
code142 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes I.NO 13.31.3

76

327

24893.04

... More
code143 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32 mm nominal dia Pipes I.NO 13.31.4

24

412

9888

... More
code144 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 40 mm nominal dia Pipes I.NO 13.31.5

272

552

150165.76

... More
code145 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 50 mm nominal dia Pipes I.NO 13.31.6

20

804

16088.6

... More
code146 - Providing and constructing "WIRE CUT BRICK MACHINEHOLE CHAMBERS" using Portland/Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber. Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Providing and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Providing and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de-watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm dia onstructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.0 M depth & SFRC cover & frame

4

29918

119673.64

... More
code147 - Constructing brick masonry circular type manhole 1.52 m internal dia at bottom 4.18m deep and 0.56m dia at top, with table moulded and non-modular bricks of class designation 50 in cement mortar 1:4, inside cement plaster 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 mixed using 40mm and down size granite metal and making necessary channel in cement concrete 1:2:4 mix with 20mm anddown size granite metal, finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diameter confirming to IS :12592, weight length of cover and frame to be not less than 182 kg, fixed in cement concrete M 15 20mm and down size broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. ( Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. 16.16.4

2

143549

287098.08

... More
code148 - Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5

8

5811

46490.08

... More
code149 - constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 500X700 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets :With common burnt clay (non modular) bricks of class designation 3.5 13.54

4

6466

25865.36

... More
code150 - Extra for Item item no. KSRB 12-.8.1 depth beyound 450mm and brick masonry chamber with table moulded non modular bricks of class designation 50 in cement mortar 1:5 for every 150mm depth or part thereof including coat of materials, labour charges, curing complete as per specifications. Specification No. 0.45 to 0.6 & 0.6 to 0.75 the nos are 60 & 40

8

744

5957.52

... More
code151 - Providing and fixing in position 32mm nominal bore gun metal non-return valve horizontal type of approved make including cost of all materials, laboru and HOM of equipments with all leads complete as per specifications. Specification No. 13-6.2.1

2

833

1666.54

... More
code152 - Providing stoneware gully trap of approved quality and make fixing in M15 and plastering with CM 1:3 wherever necessary.( Rate includes cost of all materials, fixtures and lead). 15cms x 10cms. Specification No. 12.112.2

8

288

2307.2

... More
code153 - Making wall bore in stone masonry walls and Redoing upto 45cms thick. Specification No. 37.36.1

40

312

12483.6

... More
code154 - Making wall bore in Brick masonry walls and Redoing 45cms thick. Specification No. 37.35

40

129

5191.2

... More
code155 - Drilling holes of 2.50 cms dia (roof/chajja/stone). - - in slabs upto 10 cms thick. Specification No. 37.28.2

4

161

646.84

... More
code156 - Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

4000

9

37080

... More
code157 - Providing and fixing in position 50mm nominal bore gun metal non-return valve horizontal type of approved make including cost of all materials, Labour and HOM of equipments with all leads complete as per specifications.(Specifications No. KBS 13.2.10/13.13) Non return valves : Cimberio / RB / Itap. Specification No. 13.6.4.1

4

1401

5607.32

... More
code158 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. 2.2.1)Short point upto 3Mtr from tapping point to out let via switch box

35

277

9697.45

... More
code159 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. 2.2.2)Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box

50

390

19518.5

... More
code160 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. 2.2.3)Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box

15

571

8574.75

... More
code161 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. 2.2.4)Two outlet in a row,above 3Mtr upto 6Mtr from tapping point to out let via switches

15

697

10459.65

... More
code162 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. 2.2.5)Three outlet in a row, above 6Mts upto 10Mtr from tapping point to out let via switches box

15

1018

15280.05

... More
code163 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.1) 1-2Way

35

142

4974.9

... More
code164 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.3)4-5Way

16

182

2916.96

... More
code165 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.4)6 Way

15

226

3399

... More
code166 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.5)8Way

16

268

4301.28

... More
code167 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.6) 10-12Way

12

328

3942.84

... More
code168 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.7)16 Way

20

373

7477.8

... More
code169 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.8)18 Way

25

417

10428.75

... More
code170 - Suppling and fixing PVC/metal conduit deep juction boxes 1.5.1)19/20mm deep juction box

68

50

3431.96

... More
code171 - Suppling and fixing PVC/metal conduit deep juction boxes 1.5.2) 25mm deep juction box

88

57

5075.84

... More
code172 - Suppling and fixing PVC/metal conduit deep juction boxes 1.5.3) 32mm deep juction box

35

62

2199.05

... More
code173 - Suppling and fixing PVC/metal conduit deep juction boxes 1.13)Suplay and fixing Metal Fan Box with Round Hook

65

120

7833.15

... More
code174 - Supplying and mounting 2 nos of 2 way 6amps flush type switches either surface /flush mounted on exisinting gang box or in 4mm thick plastic sheet and mounted on a flush mounted wooden box and wiring as per IS 3854 . Page No. 5, Sl No 3.2

15

175

2626.5

... More
code175 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.1)1 to 2 Module

80

141

11288.8

... More
code176 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.3) 4 Module

55

180

9913.75

... More
code177 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.4) 6 Module

55

241

13256.1

... More
code178 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.5)8 Module

55

292

16088.6

... More
code179 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.6)10-12 Module

55

354

19487.6

... More
code180 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.7)16 Module

10

408

4089.1

... More
code181 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.8)18 Module

25

470

11767.75

... More
code182 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.1) 6A one way switch

75

105

7879.5

... More
code183 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.3.6.2) 6A Two way switch

25

170

4274.5

... More
code184 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.3) 6A 3way socket.

65

176

11448.45

... More
code185 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.4) Stepped fan regulator two module.

95

367

34932.45

... More
code186 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.7) 16A one way switch

25

185

4635

... More
code187 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.10) 6/16A universal socket.

25

243

6077

... More
code188 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.11) tv/telephone socket

15

160

2410.2

... More
code189 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.12) RJ 45/I.o outlet cat 6

55

347

19091.05

... More
code190 - Concealed Conduit System: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… and running before concreting th eslab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be convered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 1.2.1) 19/20mm dia 2mm thik

2500

67

169950

... More
code191 - Concealed Conduit System: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… and running before concreting th eslab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be convered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 1.2.2) 25mm dia 2mm thik

1279.96

80

102831.9864

... More
code192 - Concealed Conduit System: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… and running before concreting th eslab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be convered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 1.2.3) 32mm dia 2.5mm thik

550

106

58349.5

... More
code193 - Groove cutting: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.1.3.1) 19/20mm dia 2mm thik

201

70

14078.04

... More
code194 - Groove cutting: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 1.3.2) 25mm dia 2mm thik

650

81

52890.5

... More
code195 - Groove cutting: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 1.3.3) 32mm dia 2.5mm thik

250

101

25492.5

... More
code196 - Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010. 2.3.2) 1.5 sqmm

800

26

21424

... More
code197 - Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010. 2.3.3) 2.5 sqmm

950

43

41097

... More
code198 - Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010. 2.3.4) 4 sqmm

950

64

61645.5

... More
code199 - Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010. 2.3.5) 6 sqmm

300

94

28428

... More
code200 - Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 V as per IS-694:1990.e. 2.6.1)3C x 2.5 mm2

75

120

9038.25

... More
code201 - Supplying and fixing regular MCB distribution boards on wall/ woodboard /flush mounting required clamps,bolts,nuts etc.. with provision for fixing suitable type capacity MCB's single phase /3 phase /single door with powder coated painting Madeoutof14SWGMS enclosure., complete. 6 Way TP & N double door ( SL No -5.19.12)

9

5088

45793.8

... More
code202 - Supplying and fixing and wiring Residualcurrentcircuitbreaker(RCCB) 240/450V up 300mA sensitivity on exsiting wood/panel board 5.20.4)32-40 Amps 2 Pole

8

4695

37566.16

... More
code203 - Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 V 1/3 phase motor upto 5 HP. Sl No 5.1

8

1984

15878.48

... More
code204 - Supplying&fixingminiaturecircuitbreakersonexistingMCBdistributionboardsusingnecessaryfixingmaterialsand'C'Typecurve,indicatorON/OFF,energycross- with Short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC60898 5.18.1)6-32Amps SP

75

427

32058.75

... More
code205 - Supplying&fixingminiaturecircuitbreakersonexistingMCBdistributionboardsusingnecessaryfixingmaterialsand'C'Typecurve,indicatorON/OFF,energycross- with Short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC60898 5.18.4)6-32Amps DP

8

761

6089.36

... More
code206 - GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg. Page No. 22, Sl No. 51.01

8

683

5466.32

... More
code207 - Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each. Page No. 22, Sl No. 51.02

8

621

4973.44

... More
code208 - Good Quality Salt for grounding purposes packed in 50 Kg gunny bag. Page No. 22, Sl No. 51.03

8

285

2280.72

... More
code209 - Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified. Page No. 23, Sl No. 51.04

8

1997

15979.68

... More
code210 - Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified. Page No. 23, Sl No. 51.05

8

338

2707.44

... More
code211 - Digging of Pit for providing GI Pipe type Earthing. In Ordinary Soil. Page No. 43, Sl No. 1.6.1

6

781

4690.62

... More
code212 - Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.. Guy Wire & GI Wire as per IS-2141. 8 SWG GI Wire (4.064 mm Dia), Std Wt: 125 Kg/KM

1

69010

69010

... More
code213 - Supply an fixing of …feet pvc batten with integrated led tube quality diffuser with life of 25000 burninng hours & 70% lumen maintance with CRI 80. power input :220-240V @ 50 hz & power factor .9 along with CE approved drivers. 2 years warranty. 11.3.1)LED light fitting 1x2' -9/10w

55

567

31214.15

... More
code214 - Supply an fixing of …feet pvc batten with integrated led tube quality diffuser with life of 25000 burninng hours & 70% lumen maintance with CRI 80. power input :220-240V @ 50 hz & power factor .9 along with CE approved drivers. 2 years warranty. 11.3.2)LED light fitting 1x4' -20/22w

100

711

71173

... More
code215 - Supplyofround /squarerecess/ surface mounted rolling type LED Downlight with......WGU10LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to main sconnector & hasswivelling unit of aluminium diecasteyeball & LED Lamp position retained by circular wirespring, with Life of 25000 burning hours & 70% lumenmaintenancewithCRI 80.PowerInput:220- 40V @50/60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition. 11.5.1)LED square or round down light 5-6W

10

588

5881.3

... More
code216 - Supplyofround /squarerecess/ surface mounted rolling type LED Downlight with......WGU10LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to main sconnector & hasswivelling unit of aluminium diecasteyeball & LED Lamp position retained by circular wirespring, with Life of 25000 burning hours & 70% lumenmaintenancewithCRI 80.PowerInput:220- 40V @50/60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition. 11.5.3)LED square or round down light 15-18W

25

1363

34093

... More
code217 - Supplying exhaust fan of 1440 RPM of 300 mm (12'') size with bracket blades complete for light duty suitable for operate of 230V 50Hz, AC Supply 12" Sweep (300 mm) sl no 6.2.1

30

3058

91742.1

... More
code218 - SupplyingofCeilingFanwithCapacitorratingAsperguidelineofBEE5starratingandIS:374/19andalsocomplywithIS:1709/1984withlatestamendment,Ratedvoltage220V/50Hz,Ratedpowerupto35W+/-10%,RatedcurrentAsperIS:374/19,Ratedpowerfactor0.9lagging(min),Ratedspeed350+/-10%RPM,Ratedairdelivery210+/-10%CubicMeterMinimum,Ratedservicevalue6.2CMM/W,ThreeBladesofbladeleaf1.05mmthickAluminiumAlloysheet,ClassBmotorinsulation,BearingTwoballbearings,Top6202,Bottom6201,asperISspecification,Motorwinding.TempriseShallnotexceed75degCoverandambientof400Cbyresistancemethodat245V,InsulationresistanceShallnotbelessthanTwoMegaOhms(2MOhms),LeakagecurrentShouldnotexceed210MicroAmp,Powerinput,W¤t,AirDelivery&FanSpeedasperIS:374/2019withlatestamendment,2yearmanufacturerWarranty.(BLDC fans Regular model (Khaitan, Crompton Greaves, Orient, Polar, Bajaj, Usha, Havells, Almonard)

75

2757

206798.25

... More
code219 - Supplying of LT UG cable having aluminium conductor PVC insulated, sheathed, galvanised, steel wire/steel tap armoured cable with PVC outer sheathing 1.1 KV class .1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 I.Class 'A' PVC Cable 35 Sqmm, 3.5 Core, (14 GI Strips - 4 x 0.8 mm)

0.75

141682

106261.515

... More
code220 - Supplying tinnd copper lugs and crimping and wiring to terminal point for wire of the following sizes. Heavy Duty Copper Terminal Long Barrel. 35 Sqmm Copper Terminal, Apprx Wt: 17 Gm

8

36

294.32

... More
code221 - Supplying and fixingof heavy duty cable glands suitable or UG cable o 1.1KV class (metal only). Page No. 28, Sl No. 63.02 32 mm dia

8

87

698.96

... More
code222 - Supply & fixing of aution/Danger name board as per drawing( BESCOM SR . CDS-1) Page No. 32, Sl No. 68.17

8

137

1103.6

... More
code223 - Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. In ordinary. Page No. 8, Sl No. 29.02

787.5

267

210892.5

... More
code224 - Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work In all kinds of soils. Depth upto 1.50m 1.6.1 vol-1

787.5

498

392584.5

... More
code225 - PVC pipe-75mm dia (Page No 20of 40 Sl no:450). Page No. 15, Sl No. 48.07

100

147

14714

... More
code226 - Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. Page No. 16, Sl No. 5.14

7

10445

73116.61

... More
code227 - Supplying of multi function digital meter with three line back light LCD type display for voltage,Current,frequency,Power,Powerfactor,KVA,KWH,KVARsuitable for 3 Phase,4 wire LT network with IP 54 degree of protection and completely wired as required wuth communication Port and Class 0.5s accuracy. a)Group A

7

9594

67161.15

... More
code228 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.y FOUR Pole 5.14.7)100 A 25 kA

7

8512

59590.65

... More
code229 - Supplying,fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based,digital readout of percentage leakage current,programable delay/auto/manual reset facility suitable to mount on DIN rail/flush munting on panel board. 5.17.9)50-63Amps TPN

7

9532

66728.55

... More
code230 - Supplying, fixing and wiring 50/5A to 400/5A 5VA Burden class 1 Current Transformer. Page No. 19, Sl No. 5.34 a)Group A

7

578

4052.02

... More
code231 - Supplying&fixingminiaturecircuitbreakersonexistingMCBdistributionboardsusingnecessaryfixingmaterialsand'C'Typecurve,indicatorON/OFF,energycross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirmingtoIEC60898.. 1 Group 'A' 5.18.8)40Amps TPN

7

3135

21947.24

... More
code232 - Supplying&fixingminiaturecircuitbreakersonexistingMCBdistributionboardsusingnecessaryfixingmaterialsand'C'Typecurve,indicatorON/OFF,energycross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirmingtoIEC60898.. 1 Group 'A' 5.18.9)50-63Amps TPN

5

3180

15903.2

... More
code233 - Supplying&fixingminiaturecircuitbreakersonexistingMCBdistributionboardsusingnecessaryfixingmaterialsand'C'Typecurve,indicatorON/OFF,energycross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirmingtoIEC60898.. 1 Group 'A' 5.18.5)40Amps DP

5

1091

5459

... More
code234 - Supplying&fixingminiaturecircuitbreakersonexistingMCBdistributionboardsusingnecessaryfixingmaterialsand'C'Typecurve,indicatorON/OFF,energycross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirmingtoIEC60898.. 1 Group 'A' 5.18.4)6-32Amps DP

5

761

3805.85

... More
code235 - Supplying …..amps rated 3phase with netural bus bar using required capacity electrolytic alluminium strips covered with heat shrinkable coloured PVC sleeve,mounted on phenolic/ERP/DMC insulator which are mounted on powder coated 40x6 mm M.S.flat frame work in existing panel board.The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts,nuts and washers etc.,complete. 5.40.1)100 A 4 x 30 x 6 mm Aluminium Strips

8

2538

20311.6

... More
code236 - FabricatingsupplyingandmountingMSboxmadeout....SWGsuitableforfloor/wallmounting,fullyweatherproofwithprovisionforbetterheatdissipation,providedwithhingedfrontcover,equippedwithtamperprooflockingarrangements,withsuitablesizeclampswithnecessarycableentrypipewithglandandboxshouldbefinishedwith7tankstreatmentwithpowdercoatedpaintand finally finished with approved colour etc., complete. 5.42.1)14SWG

15000

-

7800

... More
code237 - FabricatingsupplyingandmountingMSboxmadeout....SWGsuitableforfloor/wallmounting,fullyweatherproofwithprovisionforbetterheatdissipation,providedwithhingedfrontcover,equippedwithtamperprooflockingarrangements,withsuitablesizeclampswithnecessarycableentrypipewithglandandboxshouldbefinishedwith7tankstreatmentwithpowdercoatedpaintand finally finished with approved colour etc., complete. 5.42.2)16SWG

60000

-

26400

... More
code238 - Supplying and fixing of LED type pannel board indicating lamp with reqired colour suitable for 230/440 V A.C.50 Hz 12/24v D.C. Page No. 19, Sl No. 5.38 a)Group A

12

530

6365.4

... More
code239 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.. Page No. 20, Sl No. 5.41 5.41.1)40 x 40 x 6 mm

10

314

3141.5

... More
code240 - Supplying and drawing UTP-CAT 6E LAN cable. Page No. 36, Sl No. 8.1

950

39

37183

... More
code241 - Supplying, erecting, testing & commissioning of OFF-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with all accessories complete and Excluding batteries and wiring complete...5KVA OFF LINE UPS Two Hour back up Excluding 6x 60Ah batteries. Page No. 38, Sl No. 9.2.5

5

41094

205474.7

... More
code242 - 12 V 60 / 65 AH capacity CAPACTIY ACID BATTERY. Page No. 38, Sl No. 9.2.5

15

41094

616424.1

... More
code243 - Arrange for the 1 energy metera, CHSCOM deposit, laisening work and including road cutting permission, etc. Page No. 28, nt

6

20600

123600



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.