Karnataka Building And Other Construction Workers Welfare Board Tender

... More
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Karnataka Building And Other Construction Workers Welfare Board Tender

Works
Civil And Construction
Building Construction
Opening Date24 Mar 2025
Closing Soon23 Apr 2025
Tender Amount₹ 7,88,01,336.57 
Notes
Download

Costs

Summary

Construction Of Transit Accommodation At Anjaru Village Sy No 159/1,159/2 & 160/1, Udupi Taluk, Udupi District

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.(Page no.7 item 1.9 P.W.D. SR-2023-24 vollume -I)

1219.51

297

363316.4192

... More
code05 - Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m..(Page no.7 item 1.11 P.W.D. SR-2023-24 vollume -I)

557.97

484

270593.1312

... More
code06 - Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.. (Page no.5 item 4.1 P.W.D. SR-2023-24 vollume -II)

878

132

116036.48

... More
code07 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges ofmachinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (Page no.15 item 2.1.2 P.W.D. SR-2023-24 vollume -I),Footing , Retaining Wall,Plinth Beam

150.6

6533

984018.894

... More
code08 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges ofmachinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (Page no.15 item 2.1.2 P.W.D. SR-2023-24 vollume -I)For Flooring

120.5

6343

764413.44

... More
code09 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges ofmachinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (Page no.15 item 2.1.4P.W.D. SR-2023-24 vollume -I) Flaging Concrete, Ground floor Toliet over cinder

40.797

6963

284071.14288

... More
code10 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges ofmachinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (Page no.15 item 2.1.4P.W.D. SR-2023-24 vollume -I) For window cills for GF

11.4435

7171

82071.980955

... More
code11 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges ofmachinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (Page no.15 item 2.1.4P.W.D. SR-2023-24 vollume -I)First floor, Toliet over cinder

9.345

7032

65720.30115

... More
code12 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges ofmachinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (Page no.15 item 2.1.4P.W.D. SR-2023-24 vollume -I) First floor, For Window Cills

11.08

7243

80259.642

... More
code13 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges ofmachinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (Page no.15 item 2.1.4P.W.D. SR-2023-24 vollume -I) Second floor, For Toliet over cinder

9.345

7102

66370.9935

... More
code14 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges ofmachinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (Page no.15 item 2.1.4P.W.D. SR-2023-24 vollume -I) Second floor, For Window Cills

11.08

7315

81054.1888

... More
code15 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges ofmachinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (Page no.15 item 2.1.4P.W.D. SR-2023-24 vollume -I) Terrace floor, For Window Cills

65.7

7387

485331.156

... More
code16 - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 73% & GGBS @ 23% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge . RMC M25 Grade (Page no.18 item 2.10C P.W.D. SR-2023-24 vollume -I) For Footing

277.242

7522

2085552.945

... More
code17 - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 73% & GGBS @ 23% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge . RMC M25 Grade (Page no.18 item 2.10C P.W.D. SR-2023-24 vollume -I) For Sump, Raft, Combined Footing

29.4035

7174

210947.471805

... More
code18 - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 73% & GGBS @ 23% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge . RMC M25 Grade (Page no.18 item 2.10C P.W.D. SR-2023-24 vollume -I) For Sump Wall & RCC Wall

58.17

7661

445686.906

... More
code19 - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 73% & GGBS @ 23% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge . RMC M25 Grade (Page no.18 item 2.10C P.W.D. SR-2023-24 vollume -I) Column upto plinth,Ground Floor Column

66.31

11840

785174.7207

... More
code20 - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 73% & GGBS @ 23% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge . RMC M25 Grade (Page no.18 item 2.10C P.W.D. SR-2023-24 vollume -I) Plinth beam & Ground Stairecase and slab

199.29

10447

2082165.9768

... More
code21 - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 73% & GGBS @ 23% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge . RMC M25 Grade (Page no.18 item 2.10C P.W.D. SR-2023-24 vollume -I)Roof Beams, Lintel Beam

63.754

11144

710502.62776

... More
code22 - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 73% & GGBS @ 23% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge . RMC M25 Grade (Page no.18 item 2.10C P.W.D. SR-2023-24 vollume -I)Chajja For Ground floor

25.0968

10099

253468.89612

... More
code23 - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 73% & GGBS @ 23% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge . RMC M25 Grade (Page no.18 item 2.10C P.W.D. SR-2023-24 vollume -I)For Ground Floor to First Floor

23.04

11959

275544.1152

... More
code24 - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 73% & GGBS @ 23% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge . RMC M25 Grade (Page no.18 item 2.10C P.W.D. SR-2023-24 vollume -I)For Lintel Beam & Roof Beam

63.12

11255

710471.7768

... More
code25 - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 73% & GGBS @ 23% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge . RMC M25 Grade (Page no.18 item 2.10C P.W.D. SR-2023-24 vollume -I)For Stairecase and slab

129.08

10552

1362102.5012

... More
code26 - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 73% & GGBS @ 23% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge . RMC M25 Grade (Page no.18 item 2.10C P.W.D. SR-2023-24 vollume -I)For First Floor Chejja

26.72

10200

272561.368

... More
code27 - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 73% & GGBS @ 23% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge . RMC M25 Grade (Page no.18 item 2.10C P.W.D. SR-2023-24 vollume -I)Column First Floor to Second Floor

23.04

12077

278272.2816

... More
code28 - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 73% & GGBS @ 23% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge . RMC M25 Grade (Page no.18 item 2.10C P.W.D. SR-2023-24 vollume -I)Second Floor Lintel beam & Roof Beam

63.12

11367

717505.8696

... More
code29 - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 73% & GGBS @ 23% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge . RMC M25 Grade (Page no.18 item 2.10C P.W.D. SR-2023-24 vollume -I) Second Floor Stairecase and slab

129.08

10656

1375588.7796

... More
code30 - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 73% & GGBS @ 23% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge . RMC M25 Grade (Page no.18 item 2.10C P.W.D. SR-2023-24 vollume -I)For Second Floor Chejja

26.72

10301

275259.8208

... More
code31 - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 73% & GGBS @ 23% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge . RMC M25 Grade (Page no.18 item 2.10C P.W.D. SR-2023-24 vollume -I)For Column Second Floor to Terrace Floor

10.692

12196

130401.7704

... More
code32 - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 73% & GGBS @ 23% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge . RMC M25 Grade (Page no.18 item 2.10C P.W.D. SR-2023-24 vollume -I)For Terrace Floor Lintel Beam & Roof Beam

8.41

11478

96536.5398

... More
code33 - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 73% & GGBS @ 23% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge . RMC M25 Grade (Page no.18 item 2.10C P.W.D. SR-2023-24 vollume -I)For Terrace Floor Stairecase and slab

22.137

10761

238224.00495

... More
code34 - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 73% & GGBS @ 23% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge . RMC M25 Grade (Page no.18 item 2.10C P.W.D. SR-2023-24 vollume -I)For Chajja For Terrace floor

0.126

10402

1310.73264

... More
code35 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Page no.18 item 2.11A P.W.D. SR-2023-24 vollume -I) For Ground Floor

81.32

100191

8147600.4288

... More
code36 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Page no.18 item 2.11A P.W.D. SR-2023-24 vollume -I) For First Floor

33.23

101193

3362668.3125

... More
code37 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Page no.18 item 2.11A P.W.D. SR-2023-24 vollume -I) For Second Floor

33.23

102195

3395962.1141

... More
code38 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Page no.18 item 2.11A P.W.D. SR-2023-24 vollume -I) For Terrace Floor

6.342

103197

654479.11578

... More
code39 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(Page no.17 item 6.32 P.W.D. SR-2023-24 vollume -ii) For Ground Floor

903.33

1467

1325365.776

... More
code40 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(Page no.17 item 6.32 P.W.D. SR-2023-24 vollume -ii) For First Floor

925.77

1481

1371870.7899

... More
code41 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(Page no.17 item 6.32 P.W.D. SR-2023-24 vollume -ii) For Second Floor

924.69

1496

1383835.5726

... More
code42 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(Page no.17 item 6.32 P.W.D. SR-2023-24 vollume -ii) For Terrace Floor

412.11

1511

622784.7531

... More
code43 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(Page no.17 item 6.34 P.W.D. SR-2023-24 vollume -ii) For Ground Floor

251.77

1236

311308.5696

... More
code44 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(Page no.17 item 6.34 P.W.D. SR-2023-24 vollume -ii) For First Floor

346.86

1248

433172.6424

... More
code45 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(Page no.17 item 6.34 P.W.D. SR-2023-24 vollume -ii) For Second Floor

330.48

1269

419577.408

... More
code46 - Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge..(Page no.43 item 8.10 P.W.D. SR-2023-24 vollume -II) For Ground Floor

1015.74

236

240039.6768

... More
code47 - Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge..(Page no.43 item 8.10 P.W.D. SR-2023-24 vollume -II) For First Floor

896.81

238

214050.6108

... More
code48 - Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge..(Page no.43 item 8.10 P.W.D. SR-2023-24 vollume -II) For Second Floor

896.81

241

216167.0824

... More
code49 - Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge..(Page no.43 item 8.10 P.W.D. SR-2023-24 vollume -II) For Terrace Floor

89.14

243

21696.676

... More
code50 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge(Page no.41 item 8.2.1 P.W.D. SR-2023-24 vollume -II) (External Wall plastering ) for Ground Floor

1232.589

330

407247.4056

... More
code51 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge(Page no.41 item 8.2.1 P.W.D. SR-2023-24 vollume -II) (External Wall plastering ) for First Floor

1271.952

333

424450.3824

... More
code52 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge(Page no.41 item 8.2.1 P.W.D. SR-2023-24 vollume -II) (External Wall plastering ) for Second Floor

1268.35

337

427433.95

... More
code53 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge(Page no.41 item 8.2.1 P.W.D. SR-2023-24 vollume -II) (External Wall plastering ) for Terrace Floor

1047.9

340

356610.849

... More
code54 - Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Page no.41 item 8.4.2 P.W.D. SR-2023-24 vollume -II) (Inside plastering) For Ground Floor

2311.13

349

807601.2672

... More
code55 - Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Page no.41 item 8.4.2 P.W.D. SR-2023-24 vollume -II) (Inside plastering) For First Floor

2273.22

352

802287.5346

... More
code56 - Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Page no.41 item 8.4.2 P.W.D. SR-2023-24 vollume -II) (Inside plastering) For Second Floor

2273.22

356

810221.0724

... More
code57 - Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Page no.41 item 8.4.2 P.W.D. SR-2023-24 vollume -II) (Inside plastering) For Terrace Floor

95.34

359

34314.7728

... More
code58 - Providing and fixing suitable Plaster mesh 150mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment (Page no 43 item 8.16.2 P.W.D. SR-2023-24 vollume -II)

5500

42

234080

... More
code59 - KSRB 4-2.12 : Extra for providing throating or drip moulding to R.C.C. chajja with plastering (labour charges only) as per specifications. For Ground Floor

231.73

36

8564.7408

... More
code60 - KSRB 4-2.12 : Extra for providing throating or drip moulding to R.C.C. chajja with plastering (labour charges only) as per specifications. For First Floor

259.8

37

9695.736

... More
code61 - KSRB 4-2.12 : Extra for providing throating or drip moulding to R.C.C. chajja with plastering (labour charges only) as per specifications. For Second Floor

259.79

37

9791.4851

... More
code62 - Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications..(Page no.99 item 12.11 P.W.D. SR-2023-24 vollume -II) for Ground Floor

0.7715

154642

119306.98192

... More
code63 - Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications..(Page no.99 item 12.11 P.W.D. SR-2023-24 vollume -II) for First Floor

0.4485

156189

70050.90105

... More
code64 - Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications..(Page no.99 item 12.11 P.W.D. SR-2023-24 vollume -II) for Second Floor

0.39

157735

61516.9347

... More
code65 - Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications (Page no- 104 Item No-12.51 P.W.D. SR-2023-24 vollume -II) For Ground Floor

13

1137

14792.96

... More
code66 - Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications (Page no- 104 Item No-12.51 P.W.D. SR-2023-24 vollume -II) For First Floor

9

1149

10343.61

... More
code67 - Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications (Page no- 104 Item No-12.51 P.W.D. SR-2023-24 vollume -II) For Second Floor

8

1160

9285.36

... More
code68 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding (Page no.86 item 11.34A P.W.D. SR-2023-24 vollume -II)For Ground floor

2492.91

188

469065.9456

... More
code69 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding (Page no.86 item 11.34A P.W.D. SR-2023-24 vollume -II) For First floor

3024

190

574680.96

... More
code70 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding (Page no.86 item 11.34A P.W.D. SR-2023-24 vollume -II) For Second floor

3024

191

580366.08

... More
code71 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding (Page no.86 item 11.34A P.W.D. SR-2023-24 vollume -II) For Terrace floor

132.29

193

25637.802

... More
code72 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge..(Page no.50 item 8.51 P.W.D. SR-2023-24 vollume -II) For Ground floor

3326.87

112

372609.44

... More
code73 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge..(Page no.50 item 8.51 P.W.D. SR-2023-24 vollume -II) For First floor

3170.04

113

358594.9248

... More
code74 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge..(Page no.50 item 8.51 P.W.D. SR-2023-24 vollume -II) For Second floor

3170.04

114

362145.3696

... More
code75 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge..(Page no.50 item 8.51 P.W.D. SR-2023-24 vollume -II) For Terrace floor

184.48

115

21281.6128

... More
code76 - Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge..(Page no.46 item 8.31 P.W.D. SR-2023-24 vollume -II) For First Floor

1271.952

201

256107.5352

... More
code77 - Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge..(Page no.46 item 8.31 P.W.D. SR-2023-24 vollume -II) For second Floor

1268.35

203

257906.289

... More
code78 - Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge..(Page no.46 item 8.31 P.W.D. SR-2023-24 vollume -II) For Third Floor

1047.9

205

215175.786

... More
code79 - Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life).(Page no.46 item 8.33.1 P.W.D. SR-2023-24 vollume -II) For Ground Floor

3326.87

176

588722.9152

... More
code80 - Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life).(Page no.46 item 8.33.1 P.W.D. SR-2023-24 vollume -II) For FIrst Floor

3170.04

178

566549.5488

... More
code81 - Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life).(Page no.46 item 8.33.1 P.W.D. SR-2023-24 vollume -II) For Second Floor

3170.04

180

572160.5196

... More
code82 - Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life).(Page no.46 item 8.33.1 P.W.D. SR-2023-24 vollume -II) For Terrace Floor

184.48

182

33623.3248

... More
code83 - Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(Page no 45 item 8.29 P.W.D. SR-2023-24 vollume -II)

1232.589

316

390681.40944

... More
code84 - Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge..(Page no.48 item 8.41 P.W.D. SR-2023-24 vollume -II) For Ground Floor

21.61

187

4041.9344

... More
code85 - Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge..(Page no.48 item 8.41 P.W.D. SR-2023-24 vollume -II) For First Floor

24.75

188

4675.5225

... More
code86 - Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge..(Page no.48 item 8.41 P.W.D. SR-2023-24 vollume -II) For Second Floor

23.1

190

4407.018

... More
code87 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification(Page no.105 item 12.57.7 P.W.D. SR-2023-24 vollume -II)- do - 40mm thick both side teak For Ground Floor

35.59

5555

197709.568

... More
code88 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification(Page no.105 item 12.57.7 P.W.D. SR-2023-24 vollume -II)- do - 40mm thick both side teak For First Floor

22.049

5610

123711.42675

... More
code89 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification(Page no.105 item 12.57.7 P.W.D. SR-2023-24 vollume -II)- do - 40mm thick both side teak work For Second Floor

18.9

5666

107093.07

... More
code90 - Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness.(Page no- 112 Item No-12.94.1.(Page no- 112 Item No-12.94.1 P.W.D. SR-2023-24 vollume -II) -do- with one side prelam. For Ground Floor

33.075

3903

129098.34

... More
code91 - Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness.(Page no- 112 Item No-12.94.1.(Page no- 112 Item No-12.94.1 P.W.D. SR-2023-24 vollume -II) -do- with one side prelam. For First Floor

44.1

3942

173852.343

... More
code92 - Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness.(Page no- 112 Item No-12.94.1.(Page no- 112 Item No-12.94.1 P.W.D. SR-2023-24 vollume -II) -do- with one side prelam. For Second Floor

44.1

3981

175573.566

... More
code93 - Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 125mm.(Page no- 111 Item No-12.93.2 P.W.D. SR-2023-24 vollume -II) For Ground Floor Toilet

119.7

855

102424.896

... More
code94 - Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 125mm.(Page no- 111 Item No-12.93.2 P.W.D. SR-2023-24 vollume -II) For First Floor

159.6

864

137931.108

... More
code95 - Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 125mm.(Page no- 111 Item No-12.93.2 P.W.D. SR-2023-24 vollume -II) For Second Floor

159.6

872

139297.284

... More
code96 - Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Handles 200mm.(Page no- 218 Item No-22.15.1 P.W.D. SR-2023-24 vollume -II)

77

504

38808

... More
code97 - Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Handles 300mm(Page no- 218 Item No-22.15.2 P.W.D. SR-2023-24 vollume -II)

60

616

36960

... More
code98 - Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Aldrop 16mm dia, 300mm (Page no- 219 Item No-22.15.4 P.W.D. SR-2023-24 vollume -II)

30

420

12600

... More
code99 - Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Tower Bolts 150x10mm (Page no- 219 Item No-22.15.5 P.W.D. SR-2023-24 vollume -II)

77

134

10348.8

... More
code100 - Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Tower Bolts 250x10mm (Page no- 219 Item No-22.15.7 P.W.D. SR-2023-24 vollume -II)

30

224

6720

... More
code101 - Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc.complete : 100x58x1.90mm (Page no- 107 Item No-12.74.2 P.W.D. SR-2023-24 vollume -II)

231

101

23543.52

... More
code102 - Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc.complete : 125x64x1.90mm (Page no- 107 Item No-12.74.1 P.W.D. SR-2023-24 vollume -II)

128

114

14622.72

... More
code103 - Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. (Page no- 105 Item No-12.65 P.W.D. SR-2023-24 vollume -II)

32

66

2114.56

... More
code104 - Providing and fixing MS Holdfast of size 260mm x 25mm x 5mm thk for fixing door frame to walls including cost of materials, cutting masonry pockets for receiving MS Holdfast, one coat of shop primer , concrete filling of pockets, disposal of debris, keeping the area clean, curing, labour etc., complete as per specifications of vendor and as per architects details. (Page no- A-25 Item No-444 P.W.D. SR-2023-24 vollume -II)

180

56

10080

... More
code105 - Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Door stopper 75mm (Page -219 no22.15.10 P.W.D. SR-2023-24 vollume -II)

32

112

3584

... More
code106 - Providing and fixing of 2.5 track x 2 panel sliding windows made out of multi chambered UPVC (Matching to RAL9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware and single point locking system with touch lock. Wall thickness of frame and sash shall be of 1.8-2.0mm. Maximum possible size 1519mm x 1519mm (The cost is inclusive of all fixtures and separate charges for minor T and Ps shall not be made) (Page no.110 item 12.89 P.W.D. SR-2023-24 volume -II) For Ground Floor

69.39

7337

509122.7568

... More
code107 - Providing and fixing of 2.5 track x 2 panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware and single point locking system with touch lock. Wall thickness of frame and sash shall be of 1.8-2.0mm. Maximum possible size 1519mm x 1519mm (The cost is inclusive of all fixtures and separate charges for minor T and Ps shall not be made) (Page no.110 item 12.89 P.W.D. SR-2023-24 volume -II) For First Floor

78.24

7410

579796.7376

... More
code108 - Providing and fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware and single point locking system with touch lock. Wall thickness of frame and sash shall be of 1.8-2.0mm. Maximum possible size 1519mm x 1519mm (The cost is inclusive of all fixtures and separate charges for minor T and Ps shall not be made)(Page no.110 item 12.89 P.W.D. SR-2023-24 volume -II) For Second Floor

78.24

7483

585537.2064

... More
code109 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,.(Page no 85 item 11.28 P.W.D. SR-2023-24 vollume -II) For Ground floor

161.99

632

102507.272

... More
code110 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,.(Page no 85 item 11.28 P.W.D. SR-2023-24 vollume -II) For First floor

161.99

639

103531.0488

... More
code111 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,.(Page no 85 item 11.28 P.W.D. SR-2023-24 vollume -II) For Second floor

161.99

645

104556.4455

... More
code112 - Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Page no 84 item 11.25.2 P.W.D. SR-2023-24 vollume -II)

533.548

152

81270.03136

... More
code113 - Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin-Charge (Page no 84 item 11.26.1 P.W.D. SR-2023-24 vollume -II)

600

154

92736

... More
code114 - Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Page no 48 item 8.40 P.W.D. SR-2023-24 vollume -II) For Ground Floor

150.93

128

19439.784

... More
code115 - Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Page no 48 item 8.40 P.W.D. SR-2023-24 vollume -II) For First floor

144

130

18731.52

... More
code116 - Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Page no 48 item 8.40 P.W.D. SR-2023-24 vollume -II) For Second floor

144

131

18917.28

... More
code117 - Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Page no 48 item 8.40 P.W.D. SR-2023-24 vollume -II) For Terrace Floor floor

50.8

132

6739.128

... More
code118 - Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.(Page no 149 item 15.1 P.W.D. SR-2023-24 vollume -II).

936.79

942

882915.2071

... More
code119 - Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis)(Page no 150 item 15.7 P.W.D. SR-2023-24 vollume -II) For Ground Floor

17.89

688

12322.632

... More
code120 - Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis)(Page no 150 item 15.7 P.W.D. SR-2023-24 vollume -II) For First Floor

4.005

695

2786.1984

... More
code121 - Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis)(Page no 150 item 15.7 P.W.D. SR-2023-24 vollume -II) For Second Floor

4.005

702

2813.79285

... More
code122 - Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter:(Page no125 item 13.48 P.W.D. SR-2023-24 vollume -II)

132

325

43021.44

... More
code123 - Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments:(Page no 117 item 10.9.8 P.W.D. SR-2023-24 vollume -V).110 mm dia PVC Elbows

48

338

16235.52

... More
code124 - Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approvedmake and colour using acid and/or alkali resisting mortar bedding for Bathrooms: Toilet: Chemically exposed areas and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge.In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) with Acid and alkali resistant tile (Page no 60 item 9.7.2 P.W.D. SR-2023-24 vollume -II) For Ground Floor

599.217

1411

845615.0304

... More
code125 - Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approvedmake and colour using acid and/or alkali resisting mortar bedding for Bathrooms: Toilet: Chemically exposed areas and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge.In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) with Acid and alkali resistant tile (Page no 60 item 9.7.2 P.W.D. SR-2023-24 vollume -II) For First Floor

748.47

1425

1066801.7757

... More
code126 - Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approvedmake and colour using acid and/or alkali resisting mortar bedding for Bathrooms: Toilet: Chemically exposed areas and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge.In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) with Acid and alkali resistant tile (Page no 60 item 9.7.2 P.W.D. SR-2023-24 vollume -II) For Second Floor

748.47

1439

1077362.6874

... More
code127 - Providing and fixing 10 mm thick acid and/or alkali resistant tiles of ap proved make and colour using acid and/or alkali resisting mortar bedding for Bathrooms: Toilet: Chemically exposed areas and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) with Acid and alkali resistant tile (Page no 59 item 9.7.1 P.W.D. SR-2023-24 vollume -II) For Ground Floor

150.3

1395

209746.656

... More
code128 - Providing and fixing 10 mm thick acid and/or alkali resistant tiles of ap proved make and colour using acid and/or alkali resisting mortar bedding for Bathrooms: Toilet: Chemically exposed areas and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) with Acid and alkali resistant tile (Page no 59 item 9.7.1 P.W.D. SR-2023-24 vollume -II) For First Floor

200.4

1409

282457.788

... More
code129 - Providing and fixing 10 mm thick acid and/or alkali resistant tiles of ap proved make and colour using acid and/or alkali resisting mortar bedding for Bathrooms: Toilet: Chemically exposed areas and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) with Acid and alkali resistant tile (Page no 59 item 9.7.1 P.W.D. SR-2023-24 vollume -II)For Second Floor

200.4

1423

285255.372

... More
code130 - Providing and laying flooring and steps machine cut granite slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specifications.(Page no 63 item 9.28 P.W.D. SR-2023-24 vollume -II)

29.7

4792

142336.656

... More
code131 - Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.(Page no 63 item 9.24 P.W.D. SR-2023-24 vollume -II)For Ground FLoor

170.03

3194

543116.6272

... More
code132 - Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.(Page no 63 item 9.24 P.W.D. SR-2023-24 vollume -II)For First FLoor

107.57

3226

347040.1826

... More
code133 - Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.(Page no 63 item 9.24 P.W.D. SR-2023-24 vollume -II)For Second FLoor

106.895

3258

348276.7374

... More
code134 - Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications (Page no 23 item 7.18 P.W.D. SR-2023-24 vollume -II) For First Floor

16.02

2281

36551.7126

... More
code135 - Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications (Page no 23 item 7.18 P.W.D. SR-2023-24 vollume -II) For Second Floor

16.02

2304

36913.6044

... More
code136 - Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, griding the edge to half/full round wherever required, labour, curing complete as per specification.(Page no 65 item 9.40 P.W.D. SR-2023-24 vollume -II)

108

1043

112734.72

... More
code137 - Providing and laying Vitrified tiles with thickness 9-10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).. (Page no.62 item 9.21.2 P.W.D. SR-2023-24 vollume -II) Size of Tile 600x600 mm, For Ground Floor

590.37

1386

818583.4272

... More
code138 - Providing and laying Vitrified tiles with thickness 9-10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).. (Page no.62 item 9.21.2 P.W.D. SR-2023-24 vollume -II) Size of Tile 600x600 mm, For First Floor

550.43

1400

770833.1806

... More
code139 - Providing and laying Vitrified tiles with thickness 9-10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).. (Page no.62 item 9.21.2 P.W.D. SR-2023-24 vollume -II) Size of Tile 600x600 mm, For Second Floor

550.43

1414

778467.6447

... More
code140 - Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.

200

530

106176

... More
code141 - Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. (Page no.26 item 4.7 P.W.D. SR-2023-24 vollume -III)

150

2866

429912

... More
code142 - Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Page no.63 item 9.25 P.W.D. SR-2023-24 vollume -II)

1000

896

896000

... More
code143 - Providing and fixing Chlorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete. (Concealed work including cutting chases and good the walls etc.) (page no 122 Item No :13.32.2 & 13.32.3 )P.W.D. SR-2023-24 vollume -II 20mm Chlorinated Poly Venyl Chloride (CPVC) pipes

270.4

424

114779.392

... More
code144 - Providing and fixing Chlorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete. (Concealed work including cutting chases and good the walls etc.) (page no 122 Item No :13.32.2 & 13.32.3 )P.W.D. SR-2023-24 vollume -II 25mm Chlorinated Poly Venyl Chloride (CPVC) pipes

116.6

534

62292.384

... More
code145 - Providing and fixing Chlorinated Poly Venyl Chloride (CPVC) Pipes conforming to Is 15778, having thermal stability for hot and cold water supply inlcuding all CPVC plain and brass threaded fittings this includes jointing of pipes and fittings with one step solvent cement, trenching,refilling & testing of joints complete. (external work). (page no 122& 123 Item No - 13.33.4 & 13.33.5 )P.W.D. SR-2023-24 vollume -II, 32mm nominal OD pipes

424.59

416

176901.1776

... More
code146 - Providing and fixing Chlorinated Poly Venyl Chloride (CPVC) Pipes conforming to Is 15778, having thermal stability for hot and cold water supply inlcuding all CPVC plain and brass threaded fittings this includes jointing of pipes and fittings with one step solvent cement, trenching,refilling & testing of joints complete. (external work). (page no 122& 123 Item No - 13.33.4 & 13.33.5 )P.W.D. SR-2023-24 vollume -II, 40mm nominal OD pipes

336

534

179504.64

... More
code147 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 25mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. (Pg. No - 117 Item No :13.4.1 ) PWD SR-2023-24 Vol-II

12

614

7378.56

... More
code148 - Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 g (Page no.119 item 13.13 P.W.D. SR-2023-24 vollume -II)

133

947

126020.16

... More
code149 - Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.( Pg.no-119 Item no-13.15 ) PWD SR 2023-24 Vol-II

65

812

52780

... More
code150 - Providing and fixing gun metal non- return valve of approved quality (screwed end) -horizontal 40 mm dia. (Item No - 13.6.3.1 Pg-118 ) P.W.D. SR-2023-24 vollume -II)

4

1075

4300.8

... More
code151 - Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete25 mm nominal bore . (Page no.117 item 13.5.3.P.W.D. SR-2023-24 vollume -II)

26

332

8632

... More
code152 - Providing and fixing Pillar Cock made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy (Page no.138 item 14.48.A ) PWD SR 2023-24 Vol-II

8

1369

10958.08

... More
code153 - Providing and fixing PTMT, push cock of approved quality and colour.15 mm nominal bore, 98 mm long, weighing not less than 75 g. (Page no120 item 13.21.1 P.W.D. SR-2023-24 vollume -2 )

33

143

4730.88

... More
code154 - KSRB 13-11.1 : Providing and placing on terrace,(All floor levels )polyethylene water storage tank IS :12701 Marked , with cover and suitable locking arrangement and marking necessarry holes for inlet , outlet and over flow pipes but with out fitting andthe base suuport for tank (Page no.123 Item 13.34.P.W.D. SR-2023-24 vollume -II)

25000

10

252000

... More
code155 - Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :510x1040 mm bowl depth 250 mm (Page no.133 item 14.10.1.1 .P.W.D. SR-2023-24 vollume -II)

3

6292

18876.48

... More
code156 - Providing and fixing unplasticised PVC connection pipe with brass union 20 mm nominal bore 450mm length of PVC connection including cost of all materials, labour, HOM of equipments and testing complete as per specifications ( Page No -118, Item No -13.8.1.2 )(P.W.D. SR-2022-23 Vol-II )

46

123

5667.2

... More
code157 - Providing and fixing unplasticised PVC connection pipe with brass union 15mm nominal bore 450mm length of PVC connection including cost of all materials, labour, HOM of equipments and testing complete as per specifications. ( Page No -118, Item No - 13.8.2.1 ) SR-2023-24 vollume -II)

55

101

5605.6

... More
code158 - Supplying, installation, testing and commissioning of solar hot water heater comprising of high-quality Evacuated Glass Tube (EGT) with absorber coating collector of size 58x1800 mm. Inner tank Material-Stainless steel 304-L Grade with Aluminium Stucco cladding made of High quality PUF insulation to minimizes heat loss and hold water Temperature upto 72 Hrs...with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. Fitted with Sacrificial Anode. 300 Litre capacity- 29 nos Tubes (Page No 35, Item No 7.4.3)(PWD ELEECTRICAL VOL-VI 2023-24)

11

57711

634824.96

... More
code159 - 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.(Vol II, Pg No 137 Item No 14.40.2 SR-2023-24 vollume -II)

77

555

42775.04

... More
code160 - Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g..(Vol II, Pg No 121 Item No 13.26 SR-2023-24 vollume -II)

33

112

3696

... More
code161 - Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. .(Vol II, Pg No 137 Item No 14.38 SR-2023-24 vollume -II)

33

162

5359.2

... More
code162 - Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : (Page no. 131: item 14.3.1P.W.D. SR-2023-24 vollume -II)W.C. pan with ISI marked white solid plastic seat and lid

11

6694

73636.64

... More
code163 - Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests ( Page no131 item 14.1.1 P.W.D. SR-2021-22 vollume -2 )

33

5470

180512.64

... More
code164 - Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. (Page no135 item 14.23 P.W.D. SR-2023-24 vollume -2 )

33

1292

42651.84

... More
code165 - Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps (Page no. 132 : item 14.7.1 P.W.D. SR-2023-24 vollume -II)

43

3451

148429.12

... More
code166 - Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete ( Page no.127 item 13.59 ) PWD SR 2023-2024 Vol-II

80

246

19712

... More
code167 - Providing and fixing beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete Rectangular shape 453x357 mm(Page no136 item 14.32.2 P.W.D. SR-2023-24 vollume -2 )

39

1140

44466.24

... More
code168 - Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for. (Page no. 114 : item 10.2.1 P.W.D. SR-2023-24 vollume -5 ) Pipes of SN4, 75mm dia.

143.25

243

34815.48

... More
code169 - Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for. (Page no. 114 : item 10.2.2 P.W.D. SR-2023-24 vollume -5 ) Pipes of SN4, 110mm dia.

657

322

211921.92

... More
code170 - Providing and fixing to wall, ceiling and floor unplasticised PVC 6.00 kgs/sqcm working pressure with pipe fittings, wall clips etc., and making good to wall, ceiling and floor for sanitary pipelines including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications.(Page no.114 item 10.2.4 P.W.D. SR-2023-24 vollume -5) 160mm outer dia

135

645

87091.2

... More
code171 - Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata.k.(Page no. 10: item 1.17.1 P.W.D. SR-2023-24 vollume -I)

120.6

293

35388.864

... More
code172 - Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications (Page no.7 item 1.10 P.W.D. SR-2023-24 vollume -i)

113.45

179

20330.24

... More
code173 - Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..(Page no191 item 16.9 P.W.D. SR-2023-24 vollume -5)

28

6108

171037.44

... More
code174 - Supplying and fixing SFRC frame and cover conforming to IS 12592 (part I)-1988 and IS 12592 (part-II)- 1991 with latest amendment, including cutting slabs to the required size for the opening and fixing the cover in C.C. 1:2:4 and C.M. 1:3 plastering 20 mm thick to all exposed faces, curing for 10 days with all lead and lift with appurtenances. complete.Pg No 191 Item No 16.23.1 P.W.D. SR-2023-24 vollume -5)

32

2143

68597.76

... More
code175 - Providing and constructing "WIRE CUT BRICK MACHINEHOLE CHAMBERS" using Portland/Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber. Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Providing and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Providing and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de-watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm dia Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.0 M depth & SFRC cover & frame (Page no 192 item 16.15.1 P.W.D. SR-2021-22 vollume -5 )

2

32532

65065.28

... More
code176 - Providing and constructing "WIRE CUT BRICK MACHINEHOLE CHAMBERS" using Portland/Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber. Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Providing and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Providing and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de-watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. & 2.0 M depth includ. SFRC F&C (Page no 192 item 16.15.11 P.W.D. SR-2023-24 vollume -5 )

2

68078

136156.16

... More
code177 - Supplying heavy gauge PVCconduitpipe......mmdia..........mmthickconfirmingtoIS2509withsuitablesizebends,metal/PVCJunctionboxes,adhesivepasteetc.,andrunningbeforeconcretingtheslab.TheconduitshouldbetiedtothereinforcementrodsbyusingbindingwiresandunusedwaysofjunctionboxesandpipeendsshouldbecoveredusingPVCenenclosures,runwith18SWGGIfishwirewherever necessary 19/20 mm dia 2mm thick

759

73

56105.28

... More
code178 - Supplying heavy gauge PVCconduitpipe......mmdia..........mmthickconfirmingtoIS2509withsuitablesizebends,metal/PVCJunctionboxes,adhesivepasteetc.,andrunningbeforeconcretingtheslab.TheconduitshouldbetiedtothereinforcementrodsbyusingbindingwiresandunusedwaysofjunctionboxesandpipeendsshouldbecoveredusingPVCenenclosures,runwith18SWGGIfishwirewherever necessary 25mm dia 2mm thick

2888

87

252295.68

... More
code179 - Supplying heavy gauge PVCconduitpipe......mmdia..........mmthickconfirmingtoIS2509withsuitablesizebends,metal/PVCJunctionboxes,adhesivepasteetc.,andrunningbeforeconcretingtheslab.TheconduitshouldbetiedtothereinforcementrodsbyusingbindingwiresandunusedwaysofjunctionboxesandpipeendsshouldbecoveredusingPVCenenclosures,runwith18SWGGIfishwirewherever necessary 32 mm dia 2.5 mm thick

450

115

51912

... More
code180 - SupplyingheavygaugePVCConduitPipe....dia.......mmthickwithsuitablesizebends,metaljunctionboxesadhesivepasteetc.,bygroovecuttinginthewallandfixingbybracingUorJhooksandcementplasteringuptothewallsurfaceandrunwith18SWGGIfishwire run throughout the conduit wherever necessary.19/20 mm dia 2mm thick

242

76

18430.72

... More
code181 - SupplyingheavygaugePVCConduitPipe....dia.......mmthickwithsuitablesizebends,metaljunctionboxesadhesivepasteetc.,bygroovecuttinginthewallandfixingbybracingUorJhooksandcementplasteringuptothewallsurfaceandrunwith18SWGGIfishwire run throughout the conduit wherever necessary.25mm dia 2mm thick

742

88

65652.16

... More
code182 - SupplyingheavygaugePVCConduitPipe....dia.......mmthickwithsuitablesizebends,metaljunctionboxesadhesivepasteetc.,bygroovecuttinginthewallandfixingbybracingUorJhooksandcementplasteringuptothewallsurfaceandrunwith18SWGGIfishwire run throughout the conduit wherever necessary.32 mm dia 2.5 mm thick

180

110

19958.4

... More
code183 - Supplying and fixing PVC/metal conduit deep junction box . 25 mm deep Junction box

759

62

47604.48

... More
code184 - Supplying and fixing PVC/metal conduit deep junction box . 32 mm deep Junction box

24

68

1639.68

... More
code185 - Supplying and wiring adopting loop system in existing PVC Conduit/casing caping using COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sqmm and 1X1.0Sqmm earth wire cable confirming to IS 694 without switch, the other end of the wires shall be terminated with sufficient loose in a wood/PVC round block complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch box

253

301

76223.84

... More
code186 - Supplying and wiring adopting loop system in existing PVC Conduit/casing caping using COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sqmm and 1X1.0Sqmm earth wire cable confirming to IS 694 without switch, the other end of the wires shall be terminated with sufficient loose in a wood/PVC round block complete for each outlet. Medium point above 3Mtr up to 6Mtrs from tapping point to out let via switch box

121

424

51362.08

... More
code187 - Supplying and wiring adopting loop system in existing PVC Conduit/casing caping using COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sqmm and 1X1.0Sqmm earth wire cable confirming to IS 694 without switch, the other end of the wires shall be terminated with sufficient loose in a wood/PVC round block complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to outlet via switch box

228

621

141724.8

... More
code188 - Supplying and wiring adopting loop system in existing PVC Conduit/casing caping using COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sqmm and 1X1.0Sqmm earth wire cable confirming to IS 694 without switch, the other end of the wires shall be terminated with sufficient loose in a wood/PVC round block complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches

22

758

16681.28

... More
code189 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring as per IS-694:1990 & confirming to latest amendments.1.5 sqmm

518

29

15084.16

... More
code190 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring as per IS-694:1990 & confirming to latest amendments.2.5 sqmm

5865

47

275889.6

... More
code191 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring as per IS-694:1990 & confirming to latest amendments.4 sqmm

1584

70

111767.04

... More
code192 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring as per IS-694:1990 & confirming to latest amendments.10 sqmm

270

187

50500.8

... More
code193 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.1-2 Way

77

154

11901.12

... More
code194 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.4-5 Way

22

198

4361.28

... More
code195 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.6 Way

39

246

9609.6

... More
code196 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.8 Way

26

292

7600.32

... More
code197 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.10-12 Way

89

357

31797.92

... More
code198 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc.,complete on the existing metal/ metal PVC box. 1 to 2 Module

77

153

11814.88

... More
code199 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc.,complete on the existing metal/ metal PVC box. 4 Module

22

196

4312

... More
code200 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc.,complete on the existing metal/ metal PVC box. 6 Module

39

262

10221.12

... More
code201 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc.,complete on the existing metal/ metal PVC box. 8 Module

26

318

8270.08

... More
code202 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc.,complete on the existing metal/ metal PVC box. 10-12 Module

89

385

34289.92

... More
code203 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293.6 Amps one way

862

114

98474.88

... More
code204 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293.6Amps 3way socket.

187

191

35814.24

... More
code205 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293.Stepped Fan Regulator

87

399

34786.08

... More
code206 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293.32Amps DP switch

45

365

16430.4

... More
code207 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293.6/16Amps universal socket

45

264

11894.4

... More
code208 - Supplying and fixing miniature circuit breakers on existence MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32Amps DP

84

827

69525.12

... More
code209 - Supplying and fixing miniature circuit breakers on existence MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A TPN

12

1923

23076.48

... More
code210 - Supplying and fixing miniature circuit breakers on existence MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.50-63 A TPN

12

3458

41502.72

... More
code211 - Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts ,nuts etc., with provision for fixing suitable type capacity MCB'S single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS Enclosure.4 Way TP & N

12

4522

54270.72

... More
code212 - Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300 mA sensitivity on existing wood/ panel board.16A-25A 2 pole

12

4790

57482.88

... More
code213 - Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 12" sweep (300mm)

80

3325

266021.6

... More
code214 - Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system.48" Sweep (1200mm )

73

3342

243971.84

... More
code215 - Fixing all types and all capacities fluorescent /false ceiling/spot light/CFL/LED fittings indoor on the wall / ceiling / rafters / girders using 23 / 0.00076 " twin twisted PVC insulated wires, required nos of round blocks and clamps. On wall / ceiling / Rafters / Girders

555

136

75835.2

... More
code216 - Fixing a ceiling/wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together supplying and fixing a 5 amps ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.

73

352

25754.4

... More
code217 - Fixing one exhaust fan after making a suitablenotchinthewallandfinishingwithcementmortarandcolouringtomatchtheexistingwallorbrackets,withboltsandnutsanda5A,ceilingrosewithsufficientlengthof23/0.0076inchPVCinsulatedtwincorewireofapproved make with wire mesh and wooden frame.

80

791

63347.2

... More
code218 - Fabricating supplying and mounting MS box made out 16 SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.

250000

-

120000

... More
code219 - Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours and 70 percentage lumen maintenance with CRI greater than 80. Power Input: 220-240V at 50/60Hz and Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.

186

772

143740.8

... More
code220 - Supplying of recess mounted rolling type LED squre or round Down light 15-18 watts GU 10 LED LAMP Rib fabricated from die cst aluminum with white powder coated prewired to mains connector with suitable driver & having swiveling unit of aluminum die cast eye ball & LED Lamp position retained by circular wire spring. 5 years Warranty against any manufacturing defect working under standard electrical condition.

195

1871

364946.4

... More
code221 - Supplying of recess mounted rolling type LED squre or round Down light 24 watts GU 10 LED LAMP Rib fabricated from die cst aluminum with white powder coated prewired to mains connector with suitable driver & having swiveling unit of aluminum die cast eye ball & LED Lamp position retained by circular wire spring. 5 years Warranty against any manufacturing defect working under standard electrical condition.

171

1940

331904.16

... More
code222 - Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete upto 50 mm conduit in brick wall

425

32

13804

... More
code223 - Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete upto 50 mm conduit CC floor

335

77

25888.8

... More
code224 - Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16 SWG

75000

-

36000

... More
code225 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.

9

576

5191.2

... More
code226 - Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution)250 A

2

24399

48798.4

... More
code227 - Supplying and fixing of LT AC 3 Phase 4 Wire, 5-30 Amps DLMS Complaint Energy Meter, 1.0 Accuracy Class (Used for LT-2, LT-3 & LT-5 Installations up to 25HP/18KW)

3

2665

7996.8

... More
code228 - Supplying and fixing of LT Current Transformer, 3.75 VA, Ring type as per IS-2705 Part-1&2. CT Ratio - 400/5A, 0.5 Accuracy Class

12

652

7835.52

... More
code229 - Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.

18

4766

85800.96

... More
code230 - Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.50x6mmGI strip

180

244

43948.8

... More
code231 - Supplying and fixing of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975.70 Sqmm, 3.5 Core, (18 GI Strips - 4 x 0.8 mm)

0.25

356061

89015.36

... More
code232 - Supplying and fixing of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975.150 Sqmm, 3.5 Core, (25 GI Strips - 4 x 0.8 mm)

0.35

621213

217424.76

... More
code233 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable120 to 240 Sqmm

0.35

36151

12652.976

... More
code234 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For PVC pipes pipes 140mm dia.,., 6 kg/sqcm & class 3

200

654

130816

... More
code235 - Supplying and fixing Moulded Case Circuit Breaker (MCCB)over the existing wood/panel board using necessary screws bolts, nuts, necessary phase separators, handle and wiringcomplete. Protection of Overload and Short circuit in ThermalMagnetic Release. Micro processor release shall have EarthFault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Polesshould have protection for Short-Cicrcuit/Over Load. ForMicroprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shallbe provided with double insulation (insulation between frontcover and internal power circuits to avoid any accidentalcontact with live current carrying path with the front coveropen). Multi-pole breakers shall be designed to break all thepoles simultaneously and they shall have a single mechanism 160 A 25 kA

4

15060

60242.56

... More
code236 - Supplying and fixing Moulded Case Circuit Breaker (MCCB)over the existing wood/panel board using necessary screws bolts, nuts, necessary phase separators, handle and wiringcomplete. Protection of Overload and Short circuit in ThermalMagnetic Release. Micro processor release shall have EarthFault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Polesshould have protection for Short-Cicrcuit/Over Load. ForMicroprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shallbe provided with double insulation (insulation between frontcover and internal power circuits to avoid any accidentalcontact with live current carrying path with the front coveropen). Multi-pole breakers shall be designed to break all thepoles simultaneously and they shall have a single mechanism 400 A 36 Ka

1

31601

31601.92

... More
code237 - Supplying and fixing Moulded Case Circuit Breaker (MCCB)over the existing wood/panel board using necessary screws bolts, nuts, necessary phase separators, handle and wiringcomplete. Protection of Overload and Short circuit in ThermalMagnetic Release. Micro processor release shall have EarthFault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Polesshould have protection for Short-Cicrcuit/Over Load. ForMicroprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shallbe provided with double insulation (insulation between frontcover and internal power circuits to avoid any accidentalcontact with live current carrying path with the front coveropen). Multi-pole breakers shall be designed to break all thepoles simultaneously and they shall have a single mechanism 160 A 25 kA

4

26370

105481.6

... More
code238 - Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy

3

10432

31298.4

... More
code239 - Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 600 A 4 x 75 x 10 mm Aluminium Strips

15

6300

94500

... More
code240 - Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.

3

10365

31096.8

... More
code241 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.50 x 50 x 6 mm

40

442

17696

... More
code242 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.50 x 100 x 50 x 6 mm C channel

10

846

8467.2

... More
code243 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.Heavy Duty Copper Terminal Long BarreL.70 Sqmm Copper Terminal, Apprx Wt: 38 Gm

12

99

1196.16

... More
code244 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.Heavy Duty Copper Terminal Long BarreL150 Sqmm Copper Terminal, Apprx Wt: 98 Gm

20

204

4099.2

... More
code245 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.Heavy Duty Copper Terminal Long BarreL. 400 Sqmm Copper Terminal, Apprx Wt: 395 Gm

12

966

11598.72

... More
code246 - Supplying and errection of Pre-Stressed Tubular Spun Pole - 11 Mtr Long, 500 Kg WL(Dwg No. BESCOM/GM/QS&S/45 Dtd 24.11.2018) as per IS-13158: 1991

1

19472

19472.2

... More
code247 - Digging of Pit 2.5 Mtr depth for erection of 11 Mtr long Tubular Spun Pole as per approved Drawing. Hard Soil

1

4264

4264.7

... More
code248 - Erection of 11 Mtr long Concrete Spun Pole in a pit of 2.5 Mtr depth (Mechnised Labour)

1

2798

2798.4

... More
code249 - Pole base for 11 Mtr Spun Pole base concreting.1;4;;8 1000x1000x150 mm

1

924

924

... More
code250 - Pole concreting.1;2;4 1000x1000x2500 mm

1

15404

15404.4

... More
code251 - C) Providing Coping for Pole with CC 1:2:4 390 mm all around the Pole for an height of 300 mm for Spun Pole

1

2442

2442

... More
code252 - 11 kV, Horizontal Cross Arm - Galvanised Iron (GI)

2

545

1090.88

... More
code253 - 11 kV, Special 3 Pin Cross Arm - GI

2

1289

2578.24

... More
code254 - 11 kV Ceramic Pin Insulator (Shell only)

4

92

371.84

... More
code255 - DISC Insulator 45 kN Porcelain

4

571

2284.8

... More
code256 - Supplying of ACSR Conductor as per IS-398 (Part - 2/1996. Rabbit ACSR(6/3.35 mm Al + 1/3.35 mm St), Std Wt: 214 Kg/KM

0.2

51782

10356.416

... More
code257 - Supplying of Distribution Transformer - 3 Phase, 11kV/433V - Stacked CRGO Core with Oil as per IS-1180 (Part-1): 2014(100 kVA, Aluminium Wdg, Star 2 (5 Star)) Cable try type

1

252645

252645.12

... More
code258 - Supplying of 11 kV, 400 Amps Double Break GOS(Dwg No. BESCOM/GM/QS&S/22 Dtd 24.11.2018)

1

23811

23811.2

... More
code259 - Supplying of H - Frame Set for fixing 11 kV, 200 Amps Single Break GOS - (For DP structure for providing New GOS for sectionalisation) - GI

1

6799

6799.52

... More
code260 - Supplying and fixing of GPRS Modem with Accessories

1

5149

5149.76

... More
code261 - Supplying of 11 kV, Jointing & Cable Termination Kit as per IS-13573 Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable 3x400 Sqmm

1

5392

5392.8

... More
code262 - Supplying of Heat Shrinkable Outdoor Type Cable Termination Kit for XLPE Cable

1

6000

6000.96

... More
code263 - Supplying of Conventional RMU (VCB Type) with Copper Busbar, 350 MVA, 630 Amps as per IEC-62271/IS-3427 One Breaker (VL) Panel with Copper Busbar

1

521877

521877.44

... More
code264 - Supplying of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 95 Sqmm, 3.5 Core, (21 GI Strips - 4 x 0.8 mm)

0.25

418000

104500.2

... More
code265 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff.. HT Cable.3x185 to 240 Sqmm

0.15

71851

10777.704

... More
code266 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff.LT Cable. 300 to 400 Sqmm

0.25

38277

9569.28

... More
code267 - Supplying and Making and Fixing pot head for HT Cable only) Heat shrinkable Type Terminations 3x185 to 3x240 Sqmm

11

2976

32746.56

... More
code268 - Construction of platform with size stone, cement concert for erection of 500 kVA Transformer/Metering cubicle/Heavy Equipment.Construction of platform (1.5x1.5x1.2) Mtr in size stone, for erection of transformers/Heavy equipment including all materials, labour.Excavation of (1.5x1.5x1) Mtr pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 10 cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9 Mtr below ground level and 1.2 Mtr above ground level neatly hammer dressed in cement morter 1:6. Providing and Laying cement concrete slab 1.5x1.5x0.10 Mtr with cement concrete of 1:2:4 mix forming & cutting complete, providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completely

1

34004

34004.32

... More
code269 - Supplying of CT PT Operated ETV Meter 0.2s Accuracy Class with ABT feature and DLMS protocol with ToD with RS 232 Port UNIDIRACTIONAL (Used for HT Installation, LT Metering Cubicle (50-150 KW))

2

21968

43937.6

... More
code270 - Supplying and fixing of LT Current Transformer, 3.75 VA, Ring type as per IS-2705 Part-1&2. CT Ratio - 400/5A, 0.5 Accuracy Class

6

652

3917.76

... More
code271 - Fixing of GOS including wiring (11 kV Double Break 400 Amps)

1

1359

1359.68

... More
code272 - Stringing of Conductor. Stringing of conductor Squirrel, Weasel, binding of conductor on each insulator and dead ending on strain or disc/strain insulator by means of clamps. for Rabbit ACSR - Per km per wire

0.15

4884

732.648

... More
code273 - Digging of Pit for providing GI Pipe type Earthing. Hard Soil

12

3348

40185.6

... More
code274 - Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be

18

4766

85800.96

... More
code275 - Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 50x6mmGI strip

110

244

26857.6

... More
code276 - Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 50 x 6 mm copper strip

40

2429

97170.8

... More
code277 - Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600 x 600 x 3 mm Copper plate

4

8311

33246.08

... More
code278 - Providing chain link fencing 50 mmsize of 8 guage properly stretched between rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be welded to the Pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint. ( Item No.38.) Bescom SR 2021-22.

60

1105

66326.4

... More
code279 - 11 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification(Dwg No. BESCOM/GM/QS&S/-- Dtd 24.11.2018)

1

272688

272688.64

... More
code280 - Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. item no-12.4 (Page no.140 P.W.D. SR-2023-24 vollume -v)

1

5922

5922.55

... More
code281 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete, item no-12.1.1 )(Page no.139 P.W.D. SR-2023-24 vollume -v) 0-50 Mtrs.

50

414

20720

... More
code282 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete, item no-12.1.1 )(Page no.139 P.W.D. SR-2023-24 vollume -v)50-100 Mtrs.

50

519

25984

... More
code283 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete, item no-12.1.1 )(Page no.139 P.W.D. SR-2023-24 vollume -v) 100-150 Mtrs.

50

552

27608

... More
code284 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete, item no-12.1.1 )(Page no.139 P.W.D. SR-2023-24 vollume -v) 150-200 Mtrs.

50

640

32032

... More
code285 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete, item no-12.1.1 )(Page no.139 P.W.D. SR-2023-24 vollume -v) 200-250 Mtrs.

50

751

37576

... More
code286 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete, item no-12.1.1 )(Page no.139 P.W.D. SR-2023-24 vollume -v)250-300 Mtrs.

50

828

41440

... More
code287 - Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty.(Page no.143 item 12.32 P.W.D. SR-2023 -24 vollume -v)

45

2164

97423.2

... More
code288 - Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, ifany etc. complete with all lead and lifts and as directed by the Engineer in charge(Page no.143 item 12.34 P.W.D. SR-2021-22 vollume -v)

1

183

183.68

... More
code289 - Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments(Page no.143 item 12.33 P.W.D. SR-2023-24 vollume -v)

6

168

1008

... More
code290 - Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 3 HP etc. complete. 5.00 HP - 135 LPM @ 84 m = 12 STG Outlet Dia - 2.00" (Page no.152 item 13.13.4 P.W.D. SR-2023-24 vollume -v)

1

45707

45707.2

... More
code291 - Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 V as per IS-694:2010.. PWD Electrical SR(Page no.7 item 2.6.3 P.W.D. SR-2023-24) 3C x 6 mm2

350

245

85750

... More
code292 - Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments(Page no.155 ITEM NO - 13.28 P.W.D. SR-2023-24 vollume -v)

300

616

184800

... More
code293 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 50mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. (Pg. No - 117 Item No :13.4.1 ) PWD SR-2023-24 Vol-II

1

957

957.6

... More
code294 - Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 50 mm ( Page no.154 ITEM 13.25.1 P.W.D. SR-2023 -24 vollume -v)

1

1400

1400

... More
code295 - Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work.(Page no.156 ITEM13.32 P.W.D. SR-2023 -24 vollume -v)

1

7280

7280

... More
code296 - Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. Note: Upto 110mm dia Coil shall be used. For Grade PE80 PN6.0 :HDPE Grade PE80-PN6.0, 75mm dia(Page no.95 ITEM 9.1.2 P.W.D. SR-2023 -24 vollume -v)

100

274

27440

... More
code297 - Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.( Pg.no-119 Item no-13.15 ) PWD SR 2023-24 Vol-II

1

812

812

... More
code298 - Providing, supplying and Fixing to work site,Single Phase Submersible Pump Sets (For Sump)

1

22000

22000

... More
code299 - Supply and delivery of meter and panal board unit one number

1

12000

12000

... More
code300 - Supplying and Fixing Submersible Starter

1

8000

8000

... More
code301 - Erection of panel board and meter board

1

10000

10000

... More
code01 - 2 Tier adult bunker bed with lockable storage - A) Supply, delivery and assembling at site, Two tier Cot of dimensions 1980mm X 850mm X 1600mm, with overall dimensions/cross sections of each component as shown in the figure attached. Joints shall be interlocked and welded to render a flawless appearance. The 4 legs outer frame shall made up with 40x40 CR square tube 1.6 mm thickness, with horizontal support of dia. 31.7 mm, 1.6 mm thick CR tube and vertical bracings of 19 mm Dia, 1.2 mm wall thick at 150 mm intervals. The tops of the cot made with CR sheet of 1.22 mm thick, bed bottom four sides bending 50 X 30 mm and closing internally with C channel 50 X 30 mm, CR sheet 1.22 thickness. Inside two 2 Nos. reinforced with 2 formed length wise channels size 15 x 50 x 50 x 50 x 15 mm CR sheet of 1 mm thickness, flanged ark welded inside the length wise with 5 inches gap. B) Corner Brackets inside 8 Nos welded and outside corner brackets 8 Nos fitted with Nut bolt System (3 mm thickness 125 mm length wise). The ladder steps CR pipe 19 mm 2 mm thickness shall be fixed with 4" steps from the Vertical member of frame. The lower bed height 370 mm and two side head and top bow between top bottom to leg height 200 mm. The top of the pipe closed with MS square watcher clearance between the two beds shall be 940 mm. The hand rail of top tier shall be fixed inside of the cot holes. On the two sides of the central support frame CR tube 25.4 mm 1.22 mm thickness. C)The safety grills rails shall be sloping on one end at either side of the top tier as shown in the figure. Leg bottom to be fixed with PVC bush. Top of the legs shall be closed with metal watchers. All the CR sheet and pipes section are to be pretreated by phospoting treatment (8-stage treatment) and are to be epoxy powder coated 50-60 microns thickness grey/white shade as per IS: 101 D) Storage under the lower compartment with 2 door system and hooks to be provided for using pad lock. Storage has to be made of 22 gauge sheet with additional support of 25x25mm pipe . Size of storage has to be 1200mm width , 300mm height and 500mm depth

110

24018

2642024

... More
code02 - SINGLE COT FOR CARETAKER - A) Supply, delivery and assembling at site, Cot of dimensions 1980mm X 850mm X 570mm, with overall dimensions/cross sections of each component as shown in the figure attached. Joints shall be interlocked and welded to render a flawless appearance. The 4 legs outer frame shall made up with 40x40 CR square tube 1.6 mm thickness, with horizontal support of dia. 31.7 mm, 1.6 mm thick CR tube and vertical bracings of 19 mm dia, 1.2 mm wall thick at 150 mm intervals. The tops of the cot made with CR sheet of 1.22 mm thick, bed bottom four sides bending 50 X 30 mm and closing internally with C SHAPE channel 50 X 30 mm, CR sheet 1.22 thickness. Inside two 2 Nos. reinforced with 2 formed length wise channels size 15 x 50 x 50 x 50 x 15 mm CR sheet of 1 mm thickness, flanged ark welded inside the length wise with 5 inches gap. B) Corner Brackets inside 4 Nos welded and outside corner brackets 4 Nos fitted with Nut bolt System (3 mm thickness 125 mm length wise). The bed height 370 mm and two side head and top bow between top bottom to leg height 200 mm. C)Leg bottom to be fixed with PVC bush. Top of the legs shall be closed with metal watchers. All the CR sheet and pipes section are to be pretreated by phospoting treatment (8-stage treatment) and are to be epoxy powder coated 50-60 microns thickness grey/white shade as per IS: 101

2

16500

33000

... More
code03 - REXIN COVERED COIR BED WITH WASHABLE SHELL FABRIC COVER - U foam 50 mm and Expanded Polyurethane foam 50mm composed Bed Mattresses with Rexin Cover of ISI Mark IS : 7933-1975 quality Size- Length 1900mm Width 850mm and Thickness 100m.m. Features - Antibacterial, anti dust mites, antifungal and anti allergic -Hydrophilic and breathable fabric.Shell fabrics for pillows must have sufficient quality that provides durability even afteer washing -Zip provision has to be provided shell fabric cover

220

12285

2702829.8

... More
code04 - REXIN COVERED PILLOW WITH WASHABLE SHELL FABRIC COVER - Pillow with Rexin Cover of ISI Mark IS : 7933-1975 quality Size- Length 460mm Width 605mm All certified pillows must filled with PLA fibers must meetor exceed the minimum fill weight requirements Features - Raxine Antibacterial, anti dust mites, antifungal and anti allergic - Hydrophilic and breathable fabric Shell fabrics for pillows must have sufficient quality that provides durability even after washing -Zip provision has to be provided shell fabric cover

220

588

129575.6

... More
code05 - Steel cupboard with 8 compartment locker - Providing, Supplying and fixing of Locker cupboard with 8 Lockers Overall size 78"H x 36" W x 16"D .The cupboard shall be made out of 20g doors, 22g sides and shelf CRCA sheet .The cupboard shall have 8 lockers with doors ie.four one on top of each otherwith external locking system .Each door shall have 1 knob and name plate holder with air vents .The entire cupboard shall be Powder coated All the CR sheet and pipes section are to be pretreated by phospoting treatment (8-stage treatment) and are to be epoxy powder coated 50-60 microns thickness grey/white shade as per IS: 101

22

25000

550000

... More
code06 - Water purifier with storage - General technical description for minimum -120 liters: a) Dimension (WxDxH in mm) = 750X570X1350 b) Capacity with Comfort Level= Minimum 80LPH. c) Number of stages for Filter cum Purifier= 3 g) Number of Purifier Circuit= Minimum 2 h) Minimum Water Input Pressure in Kg/Cm2 = 0.4 i) Storage Tank Material= SS 304 j) Body Material= Front SS 304 & Rest GI Powder Coated. General Features:- a) Advanced 3 Stage Purification Process:- Having heavy duty sediment filter candle of polypropylene and silver impregnated activated carbon. Having specially treated activated carbon. Having Ultraviolet Treatment. b) Last Point Purification:- Should have the water first cooled and then purified. c) Built in Safety feature:- It should have electronic monitoring system which uses a photo resistor to stop the flow of water instantly if purification is inadequate. d) Product must be ISI certified

1

139830

139830.5

... More
code07 - PLASTIC ARMLESS CHAIR - High-quality virgin plastic build for lasting durability Ergonomic design ensures prolonged sitting comfort A glossy finish on the chair adds an appealing touch 110 kg weight capacity for secure and stable sitting Perfect for living rooms, offices, cafes, and outdoors DimensionsWidth (mm) 460 Depth (mm) 500, Height (mm) 870, Weight (Kg) 1.9 WARRANTY : 1 Year Product Warranty from the date of Purchase

10

1059

10593.2

... More
code08 - FULL STAINLESS STEEL MULTI PURPOSE TABLE - heavy duty stainless steel table of lenth 2350mm, width-550mm and height 750mm. Legs has to be made of 25mm stainless steel pipe and leg resting support has to be provided.

5

19694

98474.55

... More
code09 - DUSTBIN TROLLY TYPE LARGE SIZE - Trolly for waste removal, WH-4 Preminum Quality Material Handling Industrial Trolley, 120kg Capacity ABS Plastic, Highly Durable Number Of Drawers wheel 2. dry and wet 2 colours,4+4 has to be provided WARRANTY : 1 Year Product Warranty from the date of Purchase

2

10593

21186.44

... More
code10 - STEEL BUCKET FOR BATHING WITH NON-REMOVABLE CHAIN FIXED TO THE WALL

15

1262

18940.65

... More
code11 - BATH ROOM FLOOR MAT - COIR Solid 800 GSM Bath Mat Super Absorbent Anti Skid Door Mats

15

346

5195.25



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.