Karnataka Building And Other Construction Workers Welfare Board Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Karnataka Building And Other Construction Workers Welfare Board Tender

Works
Civil And Construction
Building Construction
Opening Date12 Dec 2024
Closing Soon27 Dec 2024
Tender Amount₹ 3,43,06,245.62 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.. (Page no.5 item 4.1 P.W.D. SR-2023-24 vollume -II)with all lead and lift as per directions of Engineer Incharge of the work

990

118

116820

... More
code05 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges ofmachinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (Page no.15 item 2.1.2 P.W.D. SR-2023-24 vollume -I)with all lead and lift as per directions of Engineer Incharge of the work For Footing

168.981

5664

957108.384

... More
code06 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges ofmachinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (Page no.15 item 2.1.4P.W.D. SR-2023-24 vollume -I)with all lead and lift as per directions of Engineer Incharge of the work For GF flagging concrete

10.071

6217

62611.407

... More
code07 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges ofmachinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (Page no.15 item 2.1.4P.W.D. SR-2023-24 vollume -I)with all lead and lift as per directions of Engineer Incharge of the work For FF Toilet concrete

2.385

6279

14975.82045

... More
code08 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges ofmachinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (Page no.15 item 2.1.4P.W.D. SR-2023-24 vollume -I)with all lead and lift as per directions of Engineer Incharge of the work For SF Toilet concrete

0.917

6341

5815.00878

... More
code09 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges ofmachinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (Page no.15 item 2.1.4P.W.D. SR-2023-24 vollume -I)with all lead and lift as per directions of Engineer Incharge of the work For window cills for TF

27.419

6403

175577.84069

... More
code10 - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge . RMC M25 Grade (Page no.18 item 2.10C P.W.D. SR-2023-24 vollume -I) For Footing

182.584

6716

1226329.08768

... More
code11 - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge . RMC M25 Grade (Page no.18 item 2.10C P.W.D. SR-2023-24 vollume -I) For Retaining Wall Foundation

28.223

6840

193070.7207

... More
code12 - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge . RMC M25 Grade (Page no.18 item 2.10C P.W.D. SR-2023-24 vollume -I) For Column upto plinth & Ground Floor Column

35.929

10572

379852.1667

... More
code13 - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge . RMC M25 Grade (Page no.18 item 2.10C P.W.D. SR-2023-24 vollume -I) For First Floor Column

23.391

10678

249769.56582

... More
code14 - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge . RMC M25 Grade (Page no.18 item 2.10C P.W.D. SR-2023-24 vollume -I) For Second Floor Column

12.96

10783

139757.2704

... More
code15 - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge . RMC M25 Grade (Page no.18 item 2.10C P.W.D. SR-2023-24 vollume -I) For Terrace Floor Column

1.296

10889

14112.74016

... More
code16 - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge . RMC M25 Grade (Page no.18 item 2.10C P.W.D. SR-2023-24 vollume -I) For Plinth beam, Ground Floor Beam & Slab

336.06

9328

3134935.71

... More
code17 - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge . RMC M25 Grade (Page no.18 item 2.10C P.W.D. SR-2023-24 vollume -I) For First Floor beam

25.72

10049

258483.428

... More
code18 - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge . RMC M25 Grade (Page no.18 item 2.10C P.W.D. SR-2023-24 vollume -I) For Second Floor beam

28.206

10149

286273.9764

... More
code19 - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge . RMC M25 Grade (Page no.18 item 2.10C P.W.D. SR-2023-24 vollume -I) For Terrace Floor beam

1.2

10248

12298.692

... More
code20 - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge . RMC M25 Grade (Page no.18 item 2.10C P.W.D. SR-2023-24 vollume -I) For First Floor Slab

73.0095

9421

687879.44691

... More
code21 - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge . RMC M25 Grade (Page no.18 item 2.10C P.W.D. SR-2023-24 vollume -I) For Second Floor Slab

31.95

9515

304006.4865

... More
code22 - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge . RMC M25 Grade (Page no.18 item 2.10C P.W.D. SR-2023-24 vollume -I) For Terrace Floor Slab

4.2

9608

40355.07

... More
code23 - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge . RMC M25 Grade (Page no.18 item 2.10C P.W.D. SR-2023-24 vollume -I) For RCC Chejja & Loft GF

8.225

9017

74169.34875

... More
code24 - Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 73% & GGBS @ 23% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge . RMC M25 Grade (Page no.18 item 2.10C P.W.D. SR-2023-24 vollume -I) For Septic Tank

24.916

6219

154952.604

... More
code25 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Page no.18 item 2.11A P.W.D. SR-2023-24 vollume -I) with all lead and lift as per directions of Engineer Incharge of the work

92.997

89457

8319232.629

... More
code26 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200m having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(Page no.17 item 6.33 P.W.D. SR-2023-24 vollume -ii) For Ground Floor

547.428

1231

673883.868

... More
code27 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200m having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(Page no.17 item 6.33 P.W.D. SR-2023-24 vollume -ii) For First Floor

325.886

1243

405177.32266

... More
code28 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200m having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(Page no.17 item 6.33 P.W.D. SR-2023-24 vollume -ii) For Second Floor

381.641

1255

479196.07242

... More
code29 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200m having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(Page no.17 item 6.33 P.W.D. SR-2023-24 vollume -ii) For Parapet Wall

54

1267

68468.22

... More
code30 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(Page no.17 item 6.34 P.W.D. SR-2023-24 vollume -ii) For Ground Floor

54.39

1104

60046.56

... More
code31 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(Page no.17 item 6.34 P.W.D. SR-2023-24 vollume -ii) For First Floor

9.81

1115

10938.5424

... More
code32 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(Page no.17 item 6.34 P.W.D. SR-2023-24 vollume -ii) For Second Floor

29.34

1126

33039.1872

... More
code33 - Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge..(Page no.43 item 8.10 P.W.D. SR-2023-24 vollume -II) with all lead and lift as per directions of Engineer Incharge of the work For Ground Floor

829.76

211

175079.36

... More
code34 - Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge..(Page no.43 item 8.10 P.W.D. SR-2023-24 vollume -II) with all lead and lift as per directions of Engineer Incharge of the work For First Floor

462.88

213

98644.3568

... More
code35 - Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge..(Page no.43 item 8.10 P.W.D. SR-2023-24 vollume -II) with all lead and lift as per directions of Engineer Incharge of the work For Second Floor

213

215

45841.86

... More
code36 - Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge..(Page no.43 item 8.10 P.W.D. SR-2023-24 vollume -II) with all lead and lift as per directions of Engineer Incharge of the work For Terrace Floor

28

217

6085.24

... More
code37 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge(Page no.41 item 8.2.1 P.W.D. SR-2023-24 vollume -II) For Ground Floor

389.203

295

114814.885

... More
code38 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge(Page no.41 item 8.2.1 P.W.D. SR-2023-24 vollume -II) For First Floor

272.174

297

81094.2433

... More
code39 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge(Page no.41 item 8.2.1 P.W.D. SR-2023-24 vollume -II) For Second Floor

163.45

300

49182.105

... More
code40 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge(Page no.41 item 8.2.1 P.W.D. SR-2023-24 vollume -II) For TErrace Floor

120

303

36462

... More
code41 - Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Page no.41 item 8.4.2 P.W.D. SR-2023-24 vollume -II) For Ground Floor

1413.965

312

441157.08

... More
code42 - Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Page no.41 item 8.4.2 P.W.D. SR-2023-24 vollume -II)For First Floor

537.8505

315

169487.44956

... More
code43 - Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Page no.41 item 8.4.2 P.W.D. SR-2023-24 vollume -II) For Second Floor

448.2825

312

140025.5217

... More
code44 - Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Page no.41 item 8.4.1 P.W.D. SR-2023-24 vollume -II) Inside wall

69.357

323

22402.311

... More
code45 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge- External Page no.42 item 8.8 Vol-II

29.52

371

10951.92

... More
code46 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.e.(Page no.50 item 8.51 P.W.D. SR-2023-24 vollume -II)

2400.098

100

240009.8

... More
code47 - Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge..(Page no.46 item 8.31 P.W.D. SR-2023-24 vollume -II)

781.377

178

139085.106

... More
code48 - Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. .(Page no.46 item 8.33.1 P.W.D. SR-2023-24 vollume -II)

2400.098

158

379215.484

... More
code49 - Providing & fixing of 2.5 track x 2 panel sliding windows made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the window frame. The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware and single point locking system with touch lock. Wall thickness of frame and sash shall be of 1.8-2.0mm. Maximum possible size 1519mm x 1519mm (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made)(Page no.110 item 12.89 P.W.D. SR 2023 24 vollume II)

127.155

6551

832992.405

... More
code50 - Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications..(Page no- 100 Item No-12.13.1 P.W.D. SR-2023-24 vollume -II)

2.351

98815

232314.065

... More
code51 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcificationdo- 40 mm thick both side Teak (Page no- 105 Item No-12.57.7 P.W.D. SR-2023-24 vollume -II)-

43.23

4960

214420.8

... More
code52 - Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge..(Page no.48 item 8.41 P.W.D. SR-2023-24 vollume -II)

56.72

167

9472.24

... More
code53 - Hold fasts.(Page no- A-25 Item No-444 P.W.D. SR-2023-24 vollume -II)

108

50

5400

... More
code54 - Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 125x70x4 mm .(Page no.107 item 12.75.2 P.W.D. SR-2023-24 vollume -II)

108

184

19872

... More
code55 - Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete 250x10mm (Page no.107 item 12.76.1 P.W.D. SR-2023-24 vollume -II)

36

435

15660

... More
code56 - Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete.(Page no- 105 Item No-12.65 P.W.D. SR-2023-24 vollume -II)

18

59

1062

... More
code57 - Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete :50x37x1.50mm.(Page no- 107 Item No-12.74.4 P.W.D. SR-2023-24 vollume -II)

78

45

3510

... More
code58 - Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete.(Page no- 105 Item No-12.63 P.W.D. SR-2023-24 vollume -II)

26

130

3380

... More
code59 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding (Page no.86 item 11.34A P.W.D. SR-2023-24 vollume -II)

2755.305

168

462891.24

... More
code60 - Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge..(Page no 149 item 15.1 P.W.D. SR-2023-24 vollume -II).

675.88

817

552193.96

... More
code61 - Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness.(Page no- 112 Item No-12.94.1 P.W.D. SR-2023-24 vollume -II)

18.9

3485

65866.5

... More
code62 - Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 125mm(Page no- 111 Item No-12.93.2 P.W.D. SR-2023-24 vollume -II)

77.4

764

59133.6

... More
code63 - Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominalthickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment - Plaster mesh 150mm wide (Page no 43 item 8.16.2 P.W.D. SR-2023-24 vollume -II)

1650

38

62700

... More
code64 - Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg/m2, including pointing in white cement mixed with pigment of matching shade complete. (Page no.71 item 10.14 P.W.D. SR-2023-24 vollume -II)

269.19

1106

297724.14

... More
code65 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete..(Page no.60 item 9.11 P.W.D. SR-2023-24 vollume -II)

73.35

889

65208.15

... More
code66 - Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.(Page no.63 item 9.24 P.W.D. SR-2023-24 vollume -II)

157.2

2852

448334.4

... More
code67 - Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis)((Page no 150 item 15.7 P.W.D. SR-2023-24 vollume -II)

77.58

615

47711.7

... More
code68 - Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. .(Page no.64 item 9.32 P.W.D. SR-2023-24 vollume -II)

288.445

2582

744764.99

... More
code69 - Providing and laying Vitrified tiles in different sizes (Thickness to be specified by manufacturer) with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm(Page no.61 item 9.17.2 P.W.D. SR-2023-24 vollume -II)

1080.436

1175

1269512.3

... More
code70 - Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.(Page no.7 item 1.9 P.W.D. SR-2023-24 vollume -I)

1804.184

266

479912.944

... More
code71 - Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications (Page no 23 item 7.18 P.W.D. SR-2023-24 vollume -II)

6.479

2017

13068.143

... More
code72 - Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin-Charge (Page no 82 item 11.26.1 P.W.D. SR-2023-24 vollume -II)

105

138

14490

... More
code73 - Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge... (Page no.84 item 11.25.2 P.W.D. SR-2023-24 vollume -II)

8828.539

136

1200681.304

... More
code74 - Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge.0.63 mm thick with zinc coating not less than 275 g/ m²(Page no 21 item 7.1 .1 P.W.D. SR-2023-24 vollume -II)

607.949

879

534387.171

... More
code75 - Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. (0.63 mm thick with zinc coating not less than 275 g/m²)(Page no 21 item 7.6 P.W.D. SR-2023-24 vollume -II)

57.9

645

37345.5

... More
code76 - Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour comple(Page no.48 item 8.41 P.W.D. SR-2023-24 vollume -II)

246.705

167

41199.735

... More
code77 - Providing & Fixing of Integral Densified Tegular/Butt edged Eco Friendly Lightweight Calcium Silicate Suspended Ceiling System in Module Size of 600x600x15mm with Exposed GI Plain T24 Grid for Offices, Hospitals, Institutions, Airports, Banking Sector, Auditoriums, Community halls, laboratories, Factories and All buildings in high humidity or coastal Areas. The Eco Friendly Lightweight Calcium Silicate Ceiling tiles shall be made from Non Cementitious Hydrated Calcium Silicate Slurry/Mixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials. Doesn't contain any toxic ingredients.The Tiles should have Humidity Resistance (RH) of 100 per cent, Water Resistance, Non Combustible: as per BS:476 Part-4, Fire Performance: as per BS 476 Part-6 for Fire Propagation, as per BS:476 Part-7 for Surface Spread of Flame, As per UK standards Fire Performace A1-S1-d0, Thermal Conductivity K 0.048 to 0.050 w/m K as per ECBC code 2007, NRC (Noise Reductions Coefficient) 0.5 to 0.75 (Semi Perforated & Fully Perforated Tiles) as per IS 8225:1987, Sound Attenuation (STA) 30-32dB,Thickness of tile should be 15mm thick with 450 kg/m3 density all around on edge resting portion with Integral Densified edge and 10mm thick with 350 kg/ m3 density in the center of the body, Light Reflectance 85%, Weight of material is 5-5.5 kg/m2 and Suitable for Green Building application with InOrganic Recycled content of 46- 50% out of which 18-20% should be LYASH and meets the GRIHA & SVAGRIHA norms under the categories: GRIHA V.2015 criterion:11&12, GRIHA V.3 criterion: 17&29 and SVAGRIHA criterion:12 The tiles Shall be laid on 24mm Wide T-Sections Flanges colour white having rotary stitching on all T sections i.e. the Main runner with a web height of 38mm and 1200mm & 600mm Cross Tees with a web height of 32mm having thickness of 0.33mm and Wall angle of 24*24mm with 0.4 mm thickness , having load carrying capacity of 15 kg/m2. The T sections should have Galvanizing of 120 g/m2 and need to be installed with Suspension system(Page no.33 item 7.54 P.W.D. SR-2023-24 vollume -II)

431.25

1887

813768.75

... More
code78 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,.(Page no 83 item 11.28 P.W.D. SR-2021-22 vollume -II) with all lead and lift as per directions of Engineer Incharge of the work.(Page no.85 item 11.28 P.W.D. SR-2023-24 vollume -II)

1231.199

565

695627.435

... More
code79 - Construction of Embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded with desired compaction. (Royalty shall be recovered @ Rs. 60.00/m3). (Page no.7 item 1.7 P.W.D. SR-2023-24 vollume -II) (Available soil)

864.6

119

102887.4

... More
code80 - Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. (Page no.26 item 4.7 P.W.D. SR-2023-24 vollume -III)

81.3

2559

208046.7

... More
code81 - Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Page no.63 item 9.25 P.W.D. SR-2023-24 vollume -II)

813

800

650400

... More
code82 - Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra). 600 x 300 x 100 mm size (Page no.74 item 8.42.6 P.W.D. SR-2023-24 vollume -III)

116.789

266

31065.874

... More
code83 - Providing and fixing in position brass bib cock of approved quality 15mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. (Page no.117 item 13.2.1.P.W.D. SR-2023-24 vollume -II)

36

286

10296

... More
code84 - Providing and fixing Chlorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete. (Concealed work including cutting chases and good the walls etc.) (page no 122 Item No :13.32.2 & 13.32.3 )P.W.D. SR-2023-24 vollume -II 20mm nominal OD pipes

78

379

29562

... More
code85 - Providing and fixing Chlorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete. (Concealed work including cutting chases and good the walls etc.) (page no 122 Item No :13.32.2 & 13.32.3 )P.W.D. SR-2023-24 vollume -II 25mm nominal OD pipes

72

477

34344

... More
code86 - Providing and fixing Chlorinated Poly Venyl Chloride (CPVC) Pipes conforming to Is 15778, having thermal stability for hot and cold water supply inlcuding all CPVC plain and brass threaded fittings this includes jointing of pipes and fittings with one step solvent cement, trenching,refilling & testing of joints complete. (external work). (page no 122& 123 Item No - 13.33.4 & 13.33.5 )P.W.D. SR-2023-24 vollume -II 32mm nominal OD pipes

140

372

52080

... More
code87 - Providing and fixing Chlorinated Poly Venyl Chloride (CPVC) Pipes conforming to Is 15778, having thermal stability for hot and cold water supply inlcuding all CPVC plain and brass threaded fittings this includes jointing of pipes and fittings with one step solvent cement, trenching,refilling & testing of joints complete. (external work). (page no 122& 123 Item No - 13.33.4 & 13.33.5 )P.W.D. SR-2023-24 vollume -II 40mm nominal OD pipes

120

477

57240

... More
code88 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 25mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. (Pg. No - 117 Item No :13.4.1 ) PWD SR-2023-24 Vol-II

4

549

2196

... More
code89 - Providing and fixing unplasticised PVC connection pipe with brass union 15mm nominal bore 450mm length of PVC connection including cost of all materials, labour, HOM of equipments and testing complete as per specifications.. ( Page No -118, Item No - 13.8.2.1 ) SR-2023-24 vollume -II

70

91

6370

... More
code90 - Providing and fixing gun metal non- return valve of approved quality (screwed end) -horizontal 40 mm dia. (Item No - 13.6.3.1 Pg-118 ) P.W.D. SR-2023-24 vollume -II)

37

960

35520

... More
code91 - Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.( Pg.no-119 Item no-13.15 ) PWD SR 2023-24 Vol-II

36

725

26100

... More
code92 - Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete25 mm nominal bore . (Page no.117 item 13.5.3.P.W.D. SR-2023-24 vollume -II)

4

332

1328

... More
code93 - KSRB 13-11.1 : Providing and placing on terrace,(All floor levels )polyethylene water storage tank IS :12701 Marked , with cover and suitable locking arrangement and marking necessarry holes for inlet , outlet and over flow pipes but with out fitting andthe base suuport for tank (Page no.123 Item 13.34.P.W.D. SR-2023-24 vollume -II)

4000

9

36000

... More
code94 - Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 3 HP etc. complete 4.00 HP - 90 LPM @ 88 m = 12 STG Outlet Dia - 2.00" (Page no.151 item 13.12.6 .P.W.D. SR-2023-24 vollume -V)

1

26730

26730

... More
code95 - Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :510x1040 mm bowl depth 250 mm (Page no.133 item 14.10.1.1 .P.W.D. SR-2023-24 vollume -II)

2

5618

11236

... More
code96 - Providing and fixing unplasticised PVC connection pipe with brass union 15mm nominal bore 450mm length of PVC connection including cost of all materials, labour, HOM of equipments and testing complete as per specifications Pg-118 Item No - 13.8.1.1(P.W.D. SR-2023-24 Vol-II )

35

83

2905

... More
code97 - Providing and fixing Pillar Cock made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy Page no.138 item 14.48.a (P.W.D. SR-2023-24 Vol-II )

13

1223

15899

... More
code98 - Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter Page no.125 item 13.48 (P.W.D. SR-2023-24 Vol-II )

144

291

41904

... More
code99 - Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid(Page no. 131: item 14.3.1 P.W.D. SR-2021-22 vollume -II)

6

5977

35862

... More
code100 - Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (Page no131 item 14.1.1 P.W.D. SR-2023-24 vollume -ii)

7

4884

34188

... More
code101 - Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer ( Page no.133 item 14.7A P.W.D. SR-2023-24 vollume -II)

20

4121

82420

... More
code102 - Providing and fixing PTMT grating of approved quality and colour Circular type 100 mm nominal dia (Page no. 120 : item 13.22.1.1 P.W.D. SR-2023-24 vollume -II)

60

41

2460

... More
code103 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc complete for PVC pipes 90mm dia, 6 kg/sqcm & class 3 (Page no.113 item 10.1.6 P.W.D. SR-2023-24 vollume -II)

80

294

23520

... More
code104 - Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for. (Page no. 114 : item 10.2.2 P.W.D. SR-2023-24 vollume -5 ) Pipes of SN4, 110mm dia.

180

288

51840

... More
code105 - Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata.k.(Page no. 10: item 1.17.1 P.W.D. SR-2023-24 vollume -I)

63.449

262

16623.638

... More
code106 - Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications (Page no.7 item 1.10 P.W.D. SR-2023-24 vollume -i)

47.25

160

7560

... More
code107 - Providing and fixing to wall, ceiling and floor unplasticised PVC 6.00 kgs/sqcm working pressure with pipe fittings, wall clips etc., and making good to wall, ceiling and floor for sanitary pipelines including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications.(Page no.114 item 10.2.4 P.W.D. SR-2023-24 vollume -5) 160mm outer dia

85

576

48960

... More
code108 - Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..(Page no191 item 16.10 P.W.D. SR-2023-24 vollume -5)

10

4236

42360

... More
code109 - Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..(Page no191 item 16.9 P.W.D. SR-2023-24 vollume -5)

12

5454

65448

... More
code110 - Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. (Page no135 item 14.23 P.W.D. SR-2023-24 vollume -2 )

6

1154

6924

... More
code111 - Providing and constructing of Machinehole chambers conical in shape at top with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15m alround the chamber and brick masonry in C.M 1:4 plaster with bricks of approved quality and CM plaster 1:3 proportion 12mm thick inside and outside except for the conical surface outside where the thickness of plaster shall be 20 mm thick, with 1 to 6 slope in the concrete towards the central drain, finished smooth and fixing of pipes in CC 1:2:4 with graded metal of 20 mm and down size including supplying and fixing SFRC Machinehole frame and cover confoming to IS 12592(Part-I): 1988 & IS 12592(Part-II) :1991 with latest amendments in CC 1:2:4, supplying and fixing of plastic foot steps staggered at 30cms apart as directed, watering, curing,barricading, danger lighting, pouring tar over M.H. frame and cover, cost of tar, shoring, strutting, dewatering, engraving Machinehole No. on the inner and outer conical surface etc. as per the drawing with all lead and lift for various diameters and depths noted below. With Table Moulded Bricks & Medium Duty SFRC Cover & Frame: For 1.2m dia Constructing Table Moulded Bricks Machinehole 1.2 m internal dia. , 1.0 M depth & Medium duty SFRC cover & frame (Page no 192 item 16.15.1 P.W.D. SR-2021-22 vollume -5 )

2

29047

58094

... More
code112 - Providing and constructing of Machinehole chambers conical in shape at top with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15m alround the chamber and brick masonry in C.M 1:4 plaster with bricks of approved quality and CM plaster 1:3 proportion 12mm thick inside and outside except for the conical surface outside where the thickness of plaster shall be 20 mm thick, with 1 to 6 slope in the concrete towards the central drain, finished smooth and fixing of pipes in CC 1:2:4 with graded metal of 20 mm and down size including supplying and fixing SFRC Machinehole frame and cover confoming to IS 12592(Part-I): 1988 & IS 12592(Part-II) :1991 with latest amendments in CC 1:2:4, supplying and fixing of plastic foot steps staggered at 30cms apart as directed, watering, curing,barricading, danger lighting, pouring tar over M.H. frame and cover, cost of tar, shoring, strutting, dewatering, engraving Machinehole No. on the inner and outer conical surface etc. as per the drawing with all lead and lift for various diameters and depths noted below. With Table Moulded Bricks & Medium Duty SFRC Cover & Frame: For 1.2m dia Constructing Table Moulded Bricks Machinehole 1.2 m internal dia. , 2.0 m depth & Medium duty SFRC cover & frame (Page no 192 item 16.15.11 P.W.D. SR-2023-24 vollume -5 )

2

60784

121568

... More
code113 - Providing and laying water proofing treatment to the Retaining wall area with PU Elastomeric Single component liquid applied, cold applied, moisture cured high tensile elastomeric PU waterproofing membrane having elongation of more than 403% and having solid content of above 93% @ 1.6kg/m2 in 2 coats to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 The cost is inclusive of surface preparation, crack filling, repair of loose mortar etc. completely as per specification)(Page no 149 item 15.4 P.W.D. SR-2023-24 volume -II)

97.9925

888

87017.34

... More
code114 - Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge..(P.No.175,I.No.17.1) PWD SR 2023-24 Vol-II

1.357

1002

1359.714

... More
code115 - Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineerin- charge...(P.No.175,I.No.17.2) PWD SR 2023-24 Vol-II

1.131

1186

1341.366

... More
code116 - Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge..(P.No.175,I.No.17.3) PWD SR 2023-24 Vol-II

9.622

1192

11469.424

... More
code117 - Providing and fixing MS inspection door of size 60 cms x 60 cms, including MS frame made of 50x50x6mm angle, shutters made of 3mm thick MS sheets, with hinges, locking arrangements at top etc. including painting with anticorrosive approved paint etc. complete including all lead and lifts etc. (.Page no 85 item 7.3 PWD SR 2023-24 Vol-II)

2

2140

4280

... More
code118 - Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of 25 MPa (as per ASTM D 412), elongation of 500% (as per ASTM D 412), puncture resistance of 1000N (as per ASTM E 154), peel adhesion to concrete 1200N/m (as per ASTM D 903), hydrostatic head resistance 70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification.(Page no 150 item 15.5)vol-II

29.52

605

17859.6

... More
code119 - Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin-Charge (Page no 43 item 8.12) vol-II

7.29

64

466.56

... More
code120 - Providing Cast iron footrest and fixing in manhole with M1o0 cement concrete block of 20x20x10x cm using 20mm and down size metal of size including cost of material labour charges curing specification Page no 75 item 11.46

4

238

952

... More
code121 - Providing and fixing MS inspection door of size 60 cms x 60 cms, including MS frame made of 50x50x6mm angle, shutters made of 3mm thick MS sheets, with hinges, locking arrangements at top etc. including painting with anticorrosive approved paint etc. complete including all lead and lifts etc. (Page no 85 item 7.3)Vol-V

1

2140

2140

... More
code122 - Supplying heavygaugePVCconduit pipe ....... dia .......mmthick confirming to IS 2509 with suitable size bends, junction boxes, adhesive pasteetc , andfixingusinginvertedwoodplugs incaseof RCCceilingandRCCwall/ stonestructureor rawl plugs incaseof brickwalls andcement plastering thedamagedportionusingheavy gauge saddles at an interval of 700mm using NF screws.19/20 mm dia 2mm thick (Page No: 2 Item No 1.1.1) (PWD ELECTRICAL 2023-24) Vol-VI

615

69

42435

... More
code123 - Supplying heavygaugePVCconduit pipe ....... dia .......mmthick confirming to IS 2509 with suitable size bends, junction boxes, adhesive pasteetc , andfixingusinginvertedwoodplugs incaseof RCCceilingandRCCwall/ stonestructureor rawl plugs incaseof brickwalls andcement plastering thedamagedportionusingheavy gauge saddles at an interval of 700mm using NF screws.19/20 mm dia 2mm thick 25mm dia 2mm thick (Page No: 2 Item No 1.1.2) (PWD ELECTRICAL 2023-24) Vol-VII

260

81

21060

... More
code124 - Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 19/20 mm dia 2mm thick (Page No: 2 Item No 1.2.1) (PWD ELECTRICAL 2023-24) Vol-VI

615

66

40590

... More
code125 - Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25mm dia 2mm thick (Page No: 2 Item No 1.2.2) (PWD ELECTRICAL 2023-24) Vol-VI

260

78

20280

... More
code126 - Supplying and fixing PVC/metal conduit deep junction box .19/20mm deep junction box (Page No: 2&3 item no.1.5.1) (PWD ELECTRICAL 2023-24) Vol-VI

55

49

2695

... More
code127 - Supplying and fixing PVC/metal conduit deep junction box . 25mm deep junction box (Page No: 2&3 item no.1.5.2) (PWD ELECTRICAL 2023-24) Vol-VI

25

56

1400

... More
code128 - Supplying and wiring adopting loop system in existing PVC Conduit/casing caping using COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sqmm and 1X1.0Sqmm earth wire cable confirming to IS 694 without switch, the other end of the wires shall be terminated with sufficient loose in a wood/PVC round block complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch box (Page No: 5 item no.2.2.1) (PWD ELECTRICAL 2023-24) Vol-VI

46

269

12374

... More
code129 - Supplying and wiring adopting loop system in existing PVC Conduit/casing caping using COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sqmm and 1X1.0Sqmm earth wire cable confirming to IS 694 without switch, the other end of the wires shall be terminated with sufficient loose in a wood/PVC round block complete for each outlet.Medium point above 3Mtr up to 6Mtrs from tapping point to out let via switch box (Page No: 5 item no.2.2.2) (PWD ELECTRICAL 2023-24) Vol-VI

23

379

8717

... More
code130 - Supplying and wiring adopting loop system in existing PVC Conduit/casing caping using COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sqmm and 1X1.0Sqmm earth wire cable confirming to IS 694 without switch, the other end of the wires shall be terminated with sufficient loose in a wood/PVC round block complete for each outlet.Long point above 6Mtr up to 10Mtr from tapping point to out let via switch box (Page No: 5 item no.2.2.3) (PWD ELECTRICAL 2023-24) Vol-VI

23

555

12765

... More
code131 - Supplying and wiring adopting loop system in existing PVC Conduit/casing caping using COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sqmm and 1X1.0Sqmm earth wire cable confirming to IS 694 without switch, the other end of the wires shall be terminated with sufficient loose in a wood/PVC round block complete for each outlet.Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches (Page No: 5 item no.2.2.4) (PWD ELECTRICAL 2023-24) Vol-VI

23

677

15571

... More
code132 - Supplying and wiring adopting loop system in existing PVC Conduit/casing caping using COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sqmm and 1X1.0Sqmm earth wire cable confirming to IS 694 without switch, the other end of the wires shall be terminated with sufficient loose in a wood/PVC round block complete for each outlet.Three outlet in a row, above 6Mtr upto 10Mtr from tapping point to outlet via switches box (Page No: 5 item no.2.2.5) (PWD ELECTRICAL 2023-24) Vol-VI

11

989

10879

... More
code133 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring as per IS-694:1990 & confirming to latest amendments 1.5 sqmm (Page No: 5 item no.2.3.2) (PWD ELECTRICAL 2023-24) Vol-VI

2750

26

71500

... More
code134 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring as per IS-694:1990 & confirming to latest amendments 2.5 sqmm (Page No: 5 item no.2.3.3) (PWD ELECTRICAL 2023-24) Vol-VI

1450

42

60900

... More
code135 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring as per IS-694:1990 & confirming to latest amendments 4 sqmm (Page No: 5 item no.2.3.4) (PWD ELECTRICAL 2023-24) Vol-VI

520

63

32760

... More
code136 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring as per IS-694:1990 & confirming to latest amendments6 sqmm (Page No: 5 item no.2.3.5) (PWD ELECTRICAL 2023-24) Vol-VI

300

92

27600

... More
code137 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall wall 1-3 Way (Page No: 8 item no.3.4.1) (PWD ELECTRICAL 2023-24) Vol-VI

45

138

6210

... More
code138 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5 Way (Page No: 8 item no.3.4.3) (PWD ELECTRICAL 2023-24) Vol-VI

32

177

5664

... More
code139 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6 Way (Page No: 8 item no.3.4.4) (PWD ELECTRICAL 2023-24) Vol-VI

22

220

4840

... More
code140 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way (Page No: 8 item no.3.4.5) (PWD ELECTRICAL 2023-24) Vol-VI

21

261

5481

... More
code141 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12 Way (Page No: 8 item no.3.4.6) (PWD ELECTRICAL 2023-24) Vol-VI

11

319

3509

... More
code142 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc.,complete on the existing metal/ metal PVC box. 1 to 2 Module (Page No: 8 item no.3.5.1) (PWD ELECTRICAL 2023-24) Vol-VI

45

137

6165

... More
code143 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc.,complete on the existing metal/ metal PVC box.4 Module (Page No: 8 item no.3.5.3) (PWD ELECTRICAL 2023-24) Vol-VI

32

175

5600

... More
code144 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc.,complete on the existing metal/ metal PVC box. 6 Module (Page No: 8 item no.3.5.4) (PWD ELECTRICAL 2023-24) Vol-VI

22

234

5148

... More
code145 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc.,complete on the existing metal/ metal PVC box. 8 Module (Page No: 8 item no.3.5.5) (PWD ELECTRICAL 2023-24) Vol-VI

21

284

5964

... More
code146 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc.,complete on the existing metal/ metal PVC box. 10-12 Module (Page No: 8 item no.3.5.6) (PWD ELECTRICAL 2023-24) Vol-VI

11

344

3784

... More
code147 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 Amps one way (Page No: 9 item no.3.6.1) (PWD ELECTRICAL 2023-24) Vol-VI

45

102

4590

... More
code148 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6Amps 3way socket. (Page No: 9 item no.3.6.3) (PWD ELECTRICAL 2023-24) Vol-VI

32

171

5472

... More
code149 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 Stepped Fan Regulator (Page No: 9 item no.3.6.4) (PWD ELECTRICAL 2023-24) Vol-VI

22

357

7854

... More
code150 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16Amps one way switch (Page No: 9 item no.3.6.7) (PWD ELECTRICAL 2023-24) Vol-VI

21

180

3780

... More
code151 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32Amps DP switch (Page No: 9 item no.3.6.9) (PWD ELECTRICAL 2023-24) Vol-VI

11

326

3586

... More
code152 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16Amps universal socket (Page No: 9 item no.3.6.10) (PWD ELECTRICAL 2023-24) Vol-VI

3

236

708

... More
code153 - Supplying and fixing miniature circuit breakers on existence MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32Amps SP (Page No:17 item no.5.18.1) (PWD ELECTRICAL 2023-24) Vol-VI

20

415

8300

... More
code154 - Supplying and fixing miniature circuit breakers on existence MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32Amps DP (Page No:17 item no.5.18.2) (PWD ELECTRICAL 2023-24) Vol-VI

6

739

4434

... More
code155 - Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts ,nuts etc., with provision for fixing suitable type capacity MCB'S single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS Enclosure 8 Way SP & N (Page No:13 item no.5.19.3) (PWD ELECTRICAL 2023-24) Vol-VI

12

1492

17904

... More
code156 - Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts ,nuts etc., with provision for fixing suitable type capacity MCB'S single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS Enclosure 4 Way SP & N (Page No:13 item no.5.19.6) (PWD ELECTRICAL 2023-24) Vol-VI

3

1524

4572

... More
code157 - Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300 mA sensitivity on existing wood/ panel board .32 Amps 2 pole (Page No:15 item no.5.20.4) (PWD ELECTRICAL 2023-24) Vol-VI

12

4559

54708

... More
code158 - Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable for operate 230V 50Hz, AC supply. (Page No: 30 ) (PWD ELECTRICAL 2023-24)( ITEM 6.1 ) Vol-VI

18

1492

26856

... More
code159 - Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system.48" Sweep (1200mm ) (Page No: 30 ) (PWD ELECTRICAL 2023-24)( ITEM 6.3.1 ) Vol-VI

26

2984

77584

... More
code160 - Supplyingwallmountingfansuitabletooperateatsingle-phase230v AC. supply. (Industrial wall mounted fan) 400 mm Sweep Industrial Wall Mounted Fan (Page No: 30 ) (PWD ELECTRICAL 2023-24)( ITEM 6.5.2 ) Vol-VI

12

3212

38544

... More
code161 - Fixing all types and all capacities fluorescent /false ceiling/spot light/CFL/LED fittings indoor on the wall / ceiling / rafters / girders using 23 / 0.00076 " twin twisted PVC insulated wires, required nos of round blocks and clamps. On wall / ceiling / Rafters / Girders (Page No: 56 ) (PWD ELECTRICAL 2023-24)( ITEM 13.7.1 ) Vol-VI

74

122

9028

... More
code162 - Fixing a ceiling/wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together supplying and fixing a 5 amps ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. (Page No: 57 ) (PWD ELECTRICAL 2023-24)( ITEM 13.11) Vol-VI

74

315

23310

... More
code163 - Fabricating supplying and mounting MS box made out 16 SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. (Page No: 20) (PWD ELECTRICAL 2023-24)( ITEM 5.42.2 ) Vol-VI

25000

-

10750

... More
code164 - Supplying & Fixing of 230 Volts 20/40 watts Fluorescent Lamp holder (Page No: 52) (PWD ELECTRICAL 2023-24)( ITEM 12.45 ) Vol-VI

34

33

1122

... More
code165 - Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.1x2'-9/10Watts (Page No: 43) (PWD ELECTRICAL 2023-24)( ITEM 11.3.1) Vol-VI

21

551

11571

... More
code166 - Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.1x4'-20/22Watts (Page No: 43) (PWD ELECTRICAL 2023-24)( ITEM 11.3.2) Vol-VI

25

690

17250

... More
code167 - Supplying of recess mounted rolling type LED squre or round Down light 15-18 watts GU 10 LED LAMP Rib fabricated from die cst aluminum with white powder coated prewired to mains connector with suitable driver & having swiveling unit of aluminum die cast eye ball & LED Lamp position retained by circular wire spring. 5 years Warranty against any manufacturing defect working under standard electrical condition. (Page No: 44) (PWD ELECTRICAL 2023-24)( ITEM 11.4.3) Vol-VI

23

1671

38433

... More
code168 - Supplying of recess mounted rolling type LED squre or round Down light 10-12 watts GU 10 LED LAMP Rib fabricated from die cst aluminum with white powder coated prewired to mains connector with suitable driver & having swiveling unit of aluminum die cast eye ball & LED Lamp position retained by circular wire spring. 5 years Warranty against any manufacturing defect working under standard electrical condition.(Page No: 43) (PWD ELECTRICAL 2023-24)( ITEM 11.5.2) Vol-VI

14

885

12390

... More
code169 - Supplying & fixing retrofit type-PL-LED Lamp ......WLED linearsourcewithCCT 6500 degreeK, CRI 70 percent.efficacy 80 lumen perW, life 25000 burning hoursandCompliance to IS 10322/IEC60598, LM79 &LM80.TheLEDaredriven byHF electronicdriverintegratedinthesystem, withPF 0.95, power lossshould 5 percent of lamp Wage., shortcircuit&opencircuitprotectionto be integratedinthecircuit,THDless than20%,LifeasperLM79.Theoperating inputvoltage shouldbebetween130to275V. Tested byNABL/CPRI accredited laboratorywith2yearsWarrantyagainst any manufacturing defect working under standard electrical condition. (Page No: 43) (PWD ELECTRICAL 2023-24)( ITEM 11.2.1) Vol-VI

68

623

42364

... More
code170 - Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete upto 50 mm conduit CC floor (Page No: 3) (PWD ELECTRICAL 2023-24)( ITEM 1.7.2) Vol-VI

145

69

10005

... More
code171 - Supplying of recess mounting non integral type........LED wluminaire comprising of pressure decast/extruded aluminium housing,with spring loaded false ceiling clamps,PowerLEDs with CCT6500 degreeK, CRI70. Efficacy 100 lumenperW, 120 degree beam spread,life 25000burning hours and Compliance to IS10322/IEC60598,LM79&LM80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in separate control gear assembly.,withPF 0.95,power loss should 5% of lamp Wage.,short circuit&open circuit protection to be integrated in the circuit,THD lessthan20%,LifeasperLM79.Theoperatinginputvoltageshouldbebetween130to275V.BISApprovedandTestedbyNABL/CPRIaccreditedlaboratorywith2yearsWarrantyagainstany manufacturing defect working under standard electrical condition LED modular down light 2x2 40-42W (Page No:45) (PWD ELECTRICAL 2023-24)( ITEM 11.6.4) Vol-VI

16

4861

77776

... More
code172 - Supplying of LT UG cable having aluminium conductor PVC Insulated, sheathed, galvanised, steel wire/steel tap armoured cable with PVC outer sheathing 1.1 KV class LClass 'A' PVC Cable 4 core 10 sqmm (Page No: 45) (PWD ELECTRICAL 2023-24)( ITEM 32.03) Vol-VI

0.2

118004

23600.8

... More
code173 - Supplying of LT UG cable having aluminium conductor PVC Insulated, sheathed, galvanised, steel wire/steel tap armoured cable with PVC outer sheathing 1.1 KV class LClass 'A' PVC Cable 3.5 core 25 sqmm (Page No: 45) (PWD ELECTRICAL 2023-24)( ITEM 32.07) Vol-VI

0.1

139549

13954.9

... More
code174 - 02 00 105-RCC Pole-9.0M Long 145 kg WL Digging of Pits 1.8 mtr depth For erection of 9 to 10-mtr Long Steel/ RCC/PSC suppons as per approved Drawing-Ordinary Soil (Page No: 3) (PWD Electrical 2023-24, Item 1.01) for Labour Charges Page No.43 Item No 1.1.1

2

7705

15410

... More
code175 - 02 00 105-RCC Pole-9.0M Long 145 kg WL Erection of RCC poles 9 to l0 mtr long but in a pit of 1.8 rntr depth. - Ordinary Soil for Labour Charges Page No.44 Item No 2.02

2

1113

2226

... More
code176 - 02 79 I l2-Double Pole TC sets for erection of 25 / 63 /100kVA 4/5 Star Rated Transformers using 9 mtr RCC Pole 145Kg WL - MS- Erection of Transformer structure Upto 25/63 KVA - Ordinary Soil (Page No: 9) (PWD Electrical 2023-24, Item 21.03) for Labour Charges Page No.43 Item No 1.1.1

1

20901

20901

... More
code177 - 02 83 007-11 kV Pin Insulator (Both Shell and G.l. Pin) Polymeric

3

205

615

... More
code178 - 02 83 320-Silcon rubber composite disk insulator /11- kv 45 kN Polymeric insulator (Page No: 5) (PWD Electrical 2023-24, Item 6.10) for Labour Charges Page No.43 Item No 1.1.1

3

186

558

... More
code179 - Earthing Material Set- Digging of pit. For providing GI Pipe type Earthing - Ordinary Soil (Page No: 5) (PWD Electrical 2023-24, Item 6.10) for Labour Charges Page No.43 Item No 1.6.1

3

2488

7464

... More
code180 - Earthing Material Set- Providing GI Pipe Earthing for lightning arresters Transformer Neutral and Transformer Metal parts (Excluding digging of pits) - Ordinary Soil for Labour Charges Page No.46 Item No 8.05

3

190

570

... More
code181 - Guy set with No.15 strain insulator & Concreting 6 materials as per Drwg No. BESCOM/GM/CP /7 /Dt; 24.10.07-Digging of Pit for GUY SET - Ordinary Soil

7

1497

10479

... More
code182 - Guy set with No.15 strain insulator & Concreting 6 materials as per Drwg No. BESCOM/GM/CP /7 /Dt; 24.10.07-Fixing of GUY Sets with break insulators making use of 7/3.15 mrn (7/10 SWG) galvanised steel wire with tum buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT) Ordinary Soil for Labour Charges Page No.45 Item No 5.10

7

266

1862

... More
code183 - 02 78 8 I I -11 kV Danger board- Fixing Danger Board - Ordinary Soil (Page No:32) (PWD Electrical 2023-24, Item 68.17) for Labour Charges Page No.45 Item No 5.15

1

230

230

... More
code184 - 02 78 9 l l-GI Barbed wire (l2mtrs/Kg) -Fixing of Anticlimbing Device Spike Type Ordinary Soil (Page No:4) (PWD Electrical 2023-24, Item 4.02) for Labour Charges Page No.45 Item No 5.09

2

131

262

... More
code185 - 03 2l 466-63kVA, Aluminum Wdg, Star 2 (5 Star)Distribution Transformers - 3 Phase,l lkV/433V - Stacked Core with Oil Barbed wire (l2mtrs/Kg) -Fixing of Anticlimbing Device Spike Type Ordinary Soil- Erection of 63 kVA Transformer on Transformer structure - Ordinary Soil (Page No:46) (PWD Electrical 2023-24, Item 12.04) for Labour Charges Page No.46 Item No 8.01

1

183738

183738

... More
code186 - 02 81110-7/10 SWG GuY Wire, (Page No:5) (PWD Electrical 2023-24, Item 8.01)

10

77

772.3

... More
code187 - 02 81 008-8 SWG GI Wire (Page No:5) (PWD Electrical 2023-24, Item 8.02)

5

75

375.2

... More
code188 - 08 21 900- Transparent Alkathine tube 19mm dia 2mm thick in coils of 30 mtrs (Page No:23) (PWD Electrical 2023-24, Item 52.01)

3

517

1551

... More
code189 - HT Single Top Support Set with Bolts Nut and Washers- Fixing of HT/LT single top support Ordinary Soil (Page No:46) (PWD Electrical 2023-24, Item 12.04) For Labour Charges Page No.45 Item No 5.06

3

252

756

... More
code190 - Loading of Transformer(whcn maintaince men for loading and unloading are not available in store) - 63 kVA-Distribution Transformer-63kVA - Ordinary Soil for Labour Charges Page No.51 Item No18.02

1

285

285

... More
code191 - Loading and unloading ofpoles (loading of poles to vehicles at stores and unlouding at workspot) - 9 mtr RCC/PSC poles-RCC Pole-9.0M Long 145 kg WL Ordinary Soil for Labour Charges Page No.51 Item No17.05.2

2

142

284

... More
code192 - 0303201-10 KV 5 ka LA polymeric type with GROUND DISCONNECTOR- Fixing of lightning arestors including wiring. - Ordinary Soil

1

4871

4871.01

... More
code193 - 0200105-RCC pole - 9 mtr long- 145kg Wl - Digging of Pits 1.8 mtr depth for errection of 9 to l0 mtr Long Steel/ RCC/PSC supports as per approved Drawing - Ordinary Soil (Page No:3) (PWD Electrical 2023-24, Item 1.01)

3

7076

21228

... More
code194 - 0200105-RCC pole - 9 mtr long- 145kg Wl - Erection of RCC polcs 9 to l0 mtr long but in a pit of 1.8 mtr depth. - Ordinary Soil for Labour Charges Page No.44 Item No 2.02

3

1113

3339

... More
code195 - 11 kv horizontal cross arm with single top support, clamp, bolt & nuts with washers for RCC poles-MS-Fixing of V-Shape/Horizontal cross arm including single top support Braces and Insulators fixing. - Ordinary Soil for Labour Charges Page No.45 Item No 5.03

6

903

5418

... More
code196 - 02 83 320- silicon rubber composite disk insulator 11 kv 45 KN polymeric insulator (Page No:19) (PWD Electrical 2023-24, Item 43.12)

9

186

1674

... More
code197 - 02 84 108 - Rabbit ACSR Condsuctor -Stringing of conductor Rabbit ACSR binding ofconductor on each insulator and dead ending on strain or disc/strain insulator bv means of clamps. - Ordinary Soil for Labour Charges Page No.46 Item No 6.02

0.37

62898

23272.26

... More
code198 - 02 81 683 - Spiral earth electroder -Providing spiral earth electrode type earthing along with pole (without charcoal, salt etc .) Ordinary Soil (Page No:4) (PWD Electrical 2023-24, Item 2.16) for Labour Charges Page No.44 Item No 2.08

5

332

1660

... More
code199 - 02 83 007 - 11 kv pin insulator (Both shell & G I Pin ) - Polymeric

12

205

2460

... More
code200 - Double pole structure including 5 kg 8-SWG GI wire for structure grounding- for 9 m rcc pole 145kg wl-with pole--Digging of Pits 1.8 mtr depth for erection of 9 to l0 rntr Long Steel/ RCC/PSC supporls as per approved Drawing - Ordinary Soil

1

21556

21556

... More
code201 - Double pole structure including 5 kg 8-SWG GI wire for structure grounding- for 9 m rcc pole 145kg wl-with pole--Erection of 2 pole structure formed out of SM rails or I -Beam ofsizes 200x100 175x9( mm,225xlOOmn, of using RCC poles 9 mtr to l0 mtr long in pits of 1.8 mtr depth for line deviation with necessary foundation, inclusive offixing ofcross Arms, Braces, Strain Insulators. - Ordinary Soil

1

4134

4134

... More
code202 - Loading and unloading of poles (loading of poles to vehicles at stores and unloading at workspot) - 9 mtr RCC/PSC poles-RCC Pote-9.0M Long 145 kg WL Ordinary Soil For Labour Charges Page No.51 Item No 17.05.2

5

142

710

... More
code203 - 03 04 212-11kv 200Amps Single Break GOS- Fixing of GOS including wiring (l lkV SB 200A) - Ordinary Soil (Page No:11) (PWD Electrical 2023-24, Item 24.01) For Labour Charges Page No.48 Item No 13.02

1

10554

10554

... More
code204 - 03 02 122-HG Fuse I IKV Class Solid Core Type- Fixing DOLO cutouts / Hom Gap Fuses including fixing of cross arms and wiring Ordinary Soil (Page No:9) (PWD Electrical 2023-24, Item 20.01) For Labour Charges Page No.48 Item No 13.01

1

1306

1306

... More
code205 - 03 0l 107-LT Protection kit- Fixing of LT Protection Kit - Ordinary Soil (Page No:9) (PWD Electrical 2023-24, Item 17.01) For Labour Charges Page No.49 Item No 15.03

1

2379

2379

... More
code206 - 63 KVA LT Wiring Kit Single Circuit- Wiring of One circuit of LT Wiring Kit for for 25/63/100 KVA DTC to the existing LT protection KitKit / Distribution Box via metering box. - Ordinary Soil

1

7340

7340

... More
code207 - 02 00 103-RCC Pole-8.0M Long 115 kg WL- Digging of Pits 1.5 mtr depth for erection of 7.5/8 mtr Long SteeI/RCC/PSC/PCC supports as per approved Drawing - Ordinary Soil (Page No:3) (PWD Electrical 2023-24, Item 1.03) For Labour Charges Page No.43 Item No 1.2.1

1

5632

5632

... More
code208 - 02 00 103-RCC Pole-8.0M Long 115 kg WL- Erection of RCC poles of 7.5 to 8 mtr long in pit of 1.5 mtr depth - Ordinary Soil For Labour Charges Page No.44 Item No 2.01

1

922

922

... More
code209 - 4 Pin Cross Arm with pole clamp, bolt & nuts & washers for RCC Pole - MS- Fixing of 4 Pin cross arm with insulator and Braces fixing. - Ordinary Soil For Labour Charges Page No. 45 Item No 5.02

2

583

1166

... More
code210 - 02 83 158-No8 Strain Insulator (Page No:5) (PWD Electrical 2023-24, Item 6.07)

8

27

216

... More
code211 - Guy set with No. 8 strain insulator & Concreting materials as per Drwg No. BESCOM/GM/CP/7/Dt; 24.10.07- Digging of Pit for GUY SET - Ordinary Soil For Labour Charges Page No.44 Item No 1.7.1

1

1465

1465

... More
code212 - Guy set with No. 8 strain insulator & Concreting materials as per Drwg No. BESCOM/GM/CP/7/Dt; 24.10.07- Fixing of GUY Scts with break insulators making use of 7/3.15 mm (7/10 SWG) galvanised steel wirc with tum buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT) Ordinary Soil For Labour Charges Page No.45 Item No 5.10

1

266

266

... More
code213 - 03 58 060-MS box for housing the ETV meter 3 phase 4 wire 5A, with associated LT CTs, class 0.5 accuracy, ring type with wiring clamps, B & N and all others accessories required ( Excluding ETV meter/ with CT ratio 100/5 for 50/63 KVA Distribution transformer Centre- LT Metering box with CTs and necessary wiring for housing ETV Meter - Ordinary Soil (Page No:28) (PWD Electrical 2023-24, Item 64.02)

1

8239

8239

... More
code214 - 04 47 662- GSM Modem

1

7001

7001

... More
code215 - 03 57 519- LT 3 Phase, 4 wire, CT operated DLMS Complaint ETV meter/5 class 5s Accuracy (Page No:22) (PWD Electrical 2023-24, Item 53.05)

1

3396

3396

... More
code216 - 03 57 202- 3 Phase (KWH Meters, static) 5-30 amps

1

1654

1654

... More
code217 - 03 36 010- L T Current transformers CT ratio -50/5A class -I accuracy3.75 VA Ring type (Page No:25) (PWD Electrical 2023-24, Item 56.03)

1

896

896

... More
code218 - Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 10%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. etc. complete.( vollume -V Page no. 140 item 12.4)

1

5288

5288

... More
code219 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 0 to 50 Mtrs (Vollume-V Page no. 139 item 12.1.1)

50

370

18500

... More
code220 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 50 to 100 Mtrs (Vollume-5 Page no. 139 item 12.1.2)

50

464

23200

... More
code221 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)(Vollume-5Page no. 139 item 12.1.3)

50

493

24650

... More
code222 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) (Vollume-v Page no. 139 item 12.1.4)

50

572

28600

... More
code223 - Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty.(Page no.143 item 12.32 P.W.D. SR-2023 -24 vollume -v)

60

1933

115980

... More
code224 - Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, ifany etc. complete with all lead and lifts and as directed by the Engineer in charge(Page no.143 item 12.34 P.W.D. SR-2021-22 vollume -v)

2

164

328

... More
code225 - Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments(Page no.143 item 12.33 P.W.D. SR-2023-24 vollume -v)

8

150

1200

... More
code226 - Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 3 HP etc. complete. 7.50 HP - 90 LPM @ 165 m = 16 STG Outlet Dia - 2.00" (Page no.152 item 13.15.7 P.W.D. SR-2023-24 vollume -v)

1

40810

40810

... More
code227 - Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 3C x 4 mm2(Vollume- V Page no.Ele SR -6 item 2.6.2)

400

168

67200

... More
code228 - Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments (Vollume-V Page no.155 item 13.28)

200

550

110000

... More
code229 - Providing and fixing in position brass gate valve with C.I wheel of approved quality (screwed end) 50mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. (Item No :13.37)SR-2018-2019

2

1739

3478

... More
code230 - Providing and fixing gun metal non- return valve of approved quality (screwed end) : 50 mm nominal bore Horizontal (Vollume-II (Page no.118 ITEM 13.6.4.1 )

4

1361

5444

... More
code231 - Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. (Vollume-V Page no.156 item 13.32)

1

6500

6500

... More
code232 - Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 (Page no.95 item 9.1.2 Vollume-V)

75

245

18375

... More
code233 - Providing and fixing brass stop cock of approved quality :20 mm nominal bore (Vollume-II Page no 116 item 13.3.2)

2

305

610

... More
code234 - Supply and delivery of meter and panal board unit one number (MR)

1

8500

8500

... More
code235 - Supplying and Fixing Submersible Starter (MR)

1

4500

4500



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.