Infrastructure Development Ports And Inland Water Transport Department Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Infrastructure Development Ports And Inland Water Transport Department Tender

Civil And Construction
Building Construction
Opening Date14 Oct 2024
Closing Date23 Oct 2024
Tender Amount₹ 37,31,286.15 
Notes
Download

Costs

Summary

Construction Of Security Room, Providing And Fixing New Galvanized Iron Profile Sheet Roofing And Changing Front Entrance Elevation With The Supervision Of Architechture At Karwar Port In Uttar Kannada District.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
1.1.4.1 - Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m.PWD SR 2023-24 vo.1 Item no1.1.4.1

56.24

271

15243.2896

... More
2.11 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to coplete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates.PWD SR 2023-24 vol.1 Item no 2.1.1 page no-15

6.42

5978

38382.3552

... More
5.4 - Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand).PWD SR 2023-24 vol 2 Item no 5.4 page no-15

11.29

7155

80787.6272

... More
6.32 - 2 Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.PWD SR 2023-24 vo.2 item no-6.32 page no-16

48.17

1467

70675.024

... More
2.2.5 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.PWD SR 2023-24 Vol-I, I.No. 2.2.5 / P.No.15

3.96

7642

30265.5672

... More
2.4.2 - Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.PWD SR 2023-24 Vol-I, I.No. 2.4.2 / P.No.16

1.01

12038

12159.3799

... More
2.5.1 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.PWD SR 2023-24 Vol-I, I.No. 2.5.1 / P.No.16

5

12623

63117.6

... More
2.5.1 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse.aggregates.PWD SR 2023-24 Vol-I, I.No. 2.5.1 / P.No.16

12.27

12772

156712.8081

... More
2.5.1 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.PWD SR 2023-24 Vol-I, I.No. 2.5.1 / P.No.16

2.81

11138

31298.904

... More
2.5.1 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates

14.16

12772

180851.9448

... More
2.11(a) - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.PWD SR 2023-24 vol.1 Item no 2.11(a) page no-18

4.704

100191

471302.41536

... More
8.1.2 - Providing 12 mm cement plaster with cement mortar 1:6 (1 cement:6 fine sand) including rounding off corners wherever required smoothrendering, providing and removing scaffolding, including cost of materials,labour, curing complete as per specifications and as per directions ofEngineer-in-charge.PWD SR 2023-24 vol.2 tem no 8.1.2 page 41

48.18

269

13004.7456

... More
8.51 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.PWD SR 2023-24 vo.2 Item no8.51 page-50

48.18

112

5396.16

... More
11.34A - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.PWD SR 2023-24 vo.2 Item no11.34A page-86

41

188

7716.2

... More
11.35.2.2 - Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.PWD SR 2023-24 vo.2 Item no11.35.2.2 page-88

16

639

10232

... More
11.37.2 - Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications.PWD SR 2023-24 vol 2 Item no 11.37.2 page no-89

4

1311

5246.08

... More
8.33.3 - Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.PWD SR 2023-24 vol 2 Item no 8.33.3 page no47

4

155

622.72

... More
12.83.2 - Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance 1mm), with wall thickness 2.0 mm ( 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm ( 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer- in-charGE.PWD SR 2023-24 vol 2 Item no 12.83.2 page no 108

28.8

267

7709.184

... More
12.55 - Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with both side prelam.PWD SR 2023-24 vol 2 Item no 12.55 page no104

7.2

2649

19079.424

... More
19.55 - Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground to the appropriate disposal area as per direction of Engineer-in-charge.PWD SR 2023-24 vol.2 Item no 19.55 page no-193

681.36

41

28208.304

... More
8.8 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finishedwith a top layer 6 mm thick cement plaster with cement mortar 1:6 (1cement : 6 fine sand) to brick masonry including rounding off cornerswherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.PWD SR 2023-24 vo.2 Item no8.8 page-42

839.04

415

348637.9008

... More
1.23 - Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering,including cost of all materials and labour with all lead and lift complete as per specifications.PWD SR 2023-24 vol 1 Item no 1.23 page no11

0.784

3003

2355.01056

... More
9.24 - Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.PWD SR 2023-24 vol 2 Item no 9.24 page no63

7.84

3194

25042.8416

... More
8.55.2 - Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge PWD SR 2023-24 vol.2 pg 51 Item No 8.55.2

839.04

59

49805.4144

... More
8.30 - Finishing walls with Acrylic Smooth exterior paint of required shade :Newwork (Two coat applied @ 1.67L/10 m² over and including priming coat ofexterior primer applied @ 2.20 kg/10 m²) with paint of approved qualityto give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surfaceeven and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.PWD SR 2023-24 vol.2 pg 46 Item No 8.30

839.04

194

163512.1152

... More
A-19 - Cudddapah slab 2.5cms thick. PWD SR 2023-24 vol 2 Item no 261 page no A-19

2.38

517

1231.5072

... More
11.16.1 - Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(P. No. 82 /I. No. 11.16.1 /PWD SR (Volume-2) 2023-24)

2811.582

152

428260.17024

... More
8.33.3 - Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.PWD SR 2023-24 vol 2 pg 47 Item No 8.33.3

134.296

155

20907.20128

... More
7.39.4 - Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Barge board (Upto 300 mm).PWD SR 2023-24 vol 2 pg 27 Item No 7.39.4

88.7

424

37651.376

... More
7.1.1 - Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge. 0.63 mm thick with zinc coating not less than 275 g/ m².PWD SR 2023-24 vol 2 pg 21 Item No 7.1.1

335.36

984

330155.2128

... More
7.39.1 - Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm)PWD SR 2023-24 vol 2 pg 26 Item No 7.39.1

37.8

505

19093.536

... More
13.48 - Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter.PWD SR 2023-24 vol 2 pg 125 Item No 13.48

49.7

292

14528.304

... More
10.1.1 - Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of the slab upto 0.50 m2PWD SR 2023-24 vol 2 pg 69 Item No10.1.1

70.44

4486

316044.5568

... More
1.8.2 - Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws atan interval of 300 mm as required. 25mm (UNI sor 2023-2024, vol 6 PWD Ele, slno 1.8.2 pg no 3)

60

35

2100

... More
1.2.2 - Supplying heavy gauge PVC conduit pipe . mm dia.mm thickconfirming to IS 2509 with suitable size bends, metal/PVC Junctionboxes, adhesive paste etc., and running before concreting the slab. Theconduit should be tied to the reinforcement rods by using bindingwires and unused ways of junction boxes and pipe ends should becovered using PVC end enclosures, run with 18SWG GI fish wirewherever necessary 25 mm dia 2 mm thick (UNI sor 2023-2024, vol 6 PWD Ele, slno 1.2.2 pg no 2)

60

78

4680

... More
1.3.2 - Supplying heavy gauge PVC Conduit Pipe . dia . mm thickwith suitable size bends, metal junction boxes adhesive paste etc., bygroove cutting in the wall and fixing by bracing U or J hooks andcement plastering upto the wall surface and run with 18 SWG GI fishwire run throughout the conduit wherever necessary 25 mm dia 2 mm thick (UNI sor 2023-2024, vol 6 PWD Ele, slno 1.3.2 pg no 2)

60

79

4740

... More
3.3.2 - Supplying and fixing surface/flush mounting unbreakable PVCmodular box suitable for mounting modular switch plates with duegroove cutting in Brick/C.C wall, including necessary rawl plugs,Machine/NF screws etc., complete. 3 Way (UNI sor 2023-2024, vol 6 PWD Ele, slno 3.3.2 pg no 8)

4

124

496

... More
3.3.3 - Supplying and fixing surface/flush mounting unbreakable PVCmodular box suitable for mounting modular switch plates with duegroove cutting in Brick/C.C wall, including necessary rawl plugs,Machine/NF screws etc., complete. 4-5 Way (UNI sor 2023-2024, vol 6 PWD Ele, slno 3.3.3 pg no 8)

4

137

548

... More
3.5.2 - Supplying and fixing superior quality modular switch mountingpolycarbonate plate with necessary supporting back plate with requirednos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module (UNI sor 2023-2024, vol 6 PWD Ele, slno 3.5.2 pg no 8)

4

161

644

... More
3.5.3 - Supplying and fixing superior quality modular switch mountingpolycarbonate plate with necessary supporting back plate with requirednos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.4 Module (UNI sor 2023-2024, vol 6 PWD Ele, slno 3.5.3 pg no 8)

4

175

700

... More
3.6.1 - Supplying and fixing of modular switch & connected accessories onexisting modular switch plate as per IS 3854 and IS 1293.6A One Way Switch (UNI sor 2023-2024, vol 6 PWD Ele, slno 3.6.1 pg no 9)

4

102

408

... More
3.6.2 - Supplying and fixing of modular switch & connected accessories onexisting modular switch plate as per IS 3854 and IS 1293.6A Two Way Switch (UNI sor 2023-2024, vol 6 PWD Ele, slno 3.6.2 pg no 9)

4

166

664

... More
3.6.9 - Supplying and fixing of modular switch & connected accessories onexisting modular switch plate as per IS 3854 and IS 1293.32A DP Switch (UNI sor 2023-2024, vol 6 PWD Ele, slno 3.6.9 pg no 9)

4

326

1304

... More
3.6.10 - Supplying and fixing of modular switch & connected accessories onexisting modular switch plate as per IS 3854 and IS 1293.6/16A Universal Socket (UNI sor 2023-2024, vol 6 PWD Ele, slno 3.6.10 pg no 9)

4

236

944

... More
2.1.1 - Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) &1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulatedcopper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existingplastic sheet/ gang box, the other end of the wires shall be terminatedwith sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switch (UNI sor 2023-2024, vol 6 PWD Ele, slno 2.1.1 pg no 5)

4

285

1140

... More
2.1.2 - Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVCConduit /casing capping using 2x1.5Sqmm (Phase & Neutral) &1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulatedcopper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existingplastic sheet/ gang box, the other end of the wires shall be terminatedwith sufficient loose length in a wood/PVC round block. complete for each outlet.Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch (UNI sor 2023-2024, vol 6 PWD Ele, slno 2.1.2 pg no 5)

4

394

1576

... More
2.1.3 - Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVCConduit /casing capping using 2x1.5Sqmm (Phase & Neutral) &1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulatedcopper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existingplastic sheet/ gang box, the other end of the wires shall be terminatedwith sufficient loose length in a wood/PVC round block. complete for each outlet.Long point above 6Mtr upto 10Mtr from tapping point to out let via switch (UNI sor 2023-2024, vol 6 PWD Ele, slno 2.1.3 pg no 5)

4

570

2280

... More
3.1.2 - Supplying 6A flush type socket and 6 A flush type SP switch eithersurface/flush mounting in existing gang box or in 4mm thick plasticsheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 Way (UNI sor 2023-2024, vol 6 PWD Ele, slno 3.1.2 pg no 8)

8

147

1176

... More
2.3.1 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010 1 mm2 (UNI sor 2023-2024, vol 6 PWD Ele, slno 2.3.1 pg no 5)

60

19

1140

... More
2.3.2 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010 1.5 mm2 (UNI sor 2023-2024, vol 6 PWD Ele, slno 2.3.2 pg no 5)

60

26

1560

... More
2.3.3 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010 2.5 mm2 (UNI sor 2023-2024, vol 6 PWD Ele, slno 2.3.2 pg no 5)

60

26

1560

... More
2.3.3 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010 4 mm2 (UNI sor 2023-2024, vol 6 PWD Ele, slno 2.3.4 pg no 5)

60

42

2520

... More
2.3.4 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010 4 mm2 (UNI sor 2023-2024, vol 6 PWD Ele, slno 2.3.4 pg no 5)

60

63

3780

... More
11.3.2 - Supplying of .feet -PVC Batten with integrated LED tube . Wwith high quality diffuser with Life of 25000 burning hours & 70%lumen maintenance with CRI 80. Power Input: 220-240V50/60Hz & Power factor 0.9 along with CE approved. 2 yearsWarranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4' - 20/22 W (UNI sor 2023-2024, vol 6 PWD Ele, slno 2.3.2 pg no 5)

8

690

5520

... More
13.7.1 - Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps On wall/ ceiling / Rafter / Girders (UNI sor 2023-2024, vol 6 PWD Ele, slno 13.7.1 pg no 56)

8

122

976

... More
5.7.3 - Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.63 A (UNI sor 2023-2024, vol 6 PWD Ele, slno 5.7.3 pg no 14)

2

401

802

... More
5.18.4 - Supplying & fixing miniature circuit breakers on existing MCBdistribution boards using necessary fixing materials and 'C' Typecurve, indicator ON/OFF, energy cross-3 with Short circuit breakingcapacity of 10K and complete wiring as required confirming to IEC60898.6-32 A DP (UNI sor 2023-2024, vol 6 PWD Ele, slno 5.18.4 pg no 17)

2

739

1478

... More
5.19.5 - Supplying and fixing regular MCB distribution boards on wall/oodboard / flush mounting using required clamps, bolts, nuts etc., withprovision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure 16 Way SP & N (UNI sor 2023-2024, vol 6 PWD Ele, slno 5.19.5 pg no 18)

2

2932

5864

... More
5.42.2 - Fabricating supplying and mounting MS box made out .SWGsuitable for floor /wall mounting, fully weather proof with provisionfor better heat dissipation, provided with hinged front cover,equipped with tamper proof locking arrangements, with suitablesize clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16 SWG (UNI sor 2023-2024, vol 6 PWD Ele, slno 5.44.2 pg no 18)

2500

-

1075

... More
11.11.4 - Supplying & fixing of retrofit type - LED bulb . W with OPAL acrylicdiffuser comprising of LED source with CCT 6500 degree K, CRI 70efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS10322IEC 60598, LM 79 & LM 80. The LED are driven by HF electronicdriver integrated in the system, with PF 0.95, power loss should 5% oflamp Wage., short circuit & open circuit protection to be integrated in thecircuit, THD less than 20%, Life as per LM 79. The operating input voltageshould be between 130 to 275 V. BIS Approved and Tested byNABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.9W, 6500K (UNI sor 2023-2024, vol 6 PWD Ele, slno 11.11.4 pg no 47)

5

154

770

... More
11.11.5 - Supplying & fixing of retrofit type - LED bulb . W with OPAL acrylicdiffuser comprising of LED source with CCT 6500 degree K, CRI 70.efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS10322IEC 60598, LM 79 LM 80. The LED are driven by HF electronicdriver integrated in the system, with PF 0.95, power loss should 5% oflamp Wage., short circuit & open circuit protection to be integrated in thecircuit, THD less than 20%, Life as per LM 79. The operating input voltageshould be between 130 to 275 V. BIS Approved and Tested byNABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.12W, 6500K (UNI sor 2023-2024, vol 6 PWD Ele, slno 11.11.5 pg no 47)

5

269

1345

... More
200 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 16 Sqmm, 2 Core, (9 GI Strips - 4 x 0.8 mm) (UNI sor 2023-2024, vol 6 PWD Ele, slno 200 pg no 13)

0.1

88418

8841.8

... More
12.56 - Supplying, fixing,wiring,earth electrode for grounding conduits, I.C. cutouts andother equipment'son the meter board using 40mmdia 2.90mmthick GI pipe2.5m long buried in a pit .Thepit should be filled with equal proportion of salt and charcoal 150 m mall-roundthe pipe to complete depth. The connection from the pipe tothe conduit etc.,is to be established through G Iwire of size as per lS Ispecification7.3.3.of IS732 using 12 mm dia bolts, nuts, washer sand check nuts etc., the pipe shall have 16 through holes of 12 mm dia (UNI sor 2023-2024, vol 6 PWD Ele, slno 12.56 pg no 54)

1

4256

4256

... More
6.5.1 - Supplying wall mounting fan suitable to operate at single-phase 230v AC. supply. 300 mm Sweep (UNI sor 2023-2024, vol 6 PWD Ele, slno 6.5.1 pg no 30)

2

2492

4984

... More
13.1 - Fixing a ceiling/Wall mounting fan of all capacities and all types to the existing 'S' 'hook with fan regulator to the existing board together with supplying and fixing 5A. ceilingrose, necessary length o 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. (UNI sor 2023-2024, vol 6 PWD Ele, slno 13.10 pg no 57)

2

171

342

... More
51.02 - LT Single Phase 5-30 Amps, DLMS Complaint Static Energy Meter, 1.0 Accuracy Class (Used for LT-2, LT-3 & LT-5 Installations) (UNI sor 2023-2024, vol 6 PWD Ele, slno 51.02 pg no 22)

1

958

958



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.