Infrastructure Development Ports And Inland Water Transport Department Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Infrastructure Development Ports And Inland Water Transport Department Tender

Works
Civil And Construction
Agriculture or Forestry Works
Opening Date4 Mar 2024
Closing Date11 Mar 2024
Tender Amount₹ 10,62,02,329.21 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
12.17 - Providing and fixing in position fully panelled Honne wood shutters for doors with , stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures)

22.5

5109

114959.25

... More
12.54 - Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.

17.1

498

8528.625

... More
12.55.2 - with one side prelam

4.73

2998

14184.324

... More
12.86 - Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8+-0.2 mm. Maximum possible size – 1519mm x 1519mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made)

23.83

6134

146175.603

... More
15.1 - Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per Sqm to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per Sqm and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.

260.52

782

203791.77

... More
8.51 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.

585.88

87

51059.442

... More
8.39 - Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.

774.39

99

77245.4025

... More
8.28 - Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 Sqm) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.

201.84

69

13987.512

... More
8.47 - Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.

12.67

112

1423.4745

... More
8.4 - Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.

90.36

94

8539.02

... More
9.32 - Providing and laying heavy duty cobble stones 75mm thick interlock pavers, using cement and course sand for manufacture of blocks of approved size, shape and colour with a minimum compressive strength of 281 kg per Sqm over 50mm thick sand bed ( average thickness ) and compacting with plate vibrator having 3 tons compaction force thereby forcing part of sand underneath to come up in between joints, final compaction of paver surface joints into its final level, including cost of materials, labour and Usage charges of machinery complete as per specifications.

63.36

1202

76174.56

... More
4.1 - Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/Sqm including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.

203.67

99

20316.0825

... More
17.1 - Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

250

1008

252000

... More
17.2 - Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

250

390

97650

... More
14.3.1 - W.C. pan with ISI marked white solid plastic seat and lid

3

5255

15765.75

... More
14.7.2 - White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap

2

2263

4527.6

... More
14.7.10 - Stainless Steel AISI-304(18/8) Round basin 405x355 mm with single 15 mm C.P. brass pillar tap

1

3267

3267.6

... More
13.2.2 - 20 mm nominal bore

7

362

2535.75

... More
13.4.2 - 32 mm nominal bore

2

605

1211.7

... More
13.4.1 - 25 mm nominal bore

3

554

1663.2

... More
13.6.2.1 - Horizontal

1

676

676.2

... More
14.31 - Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

3

1019

3058.65

... More
14.40.2 - 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.

3

399

1197

... More
A130A - Providing and Filling in foundation with granite / trap broken metal 100mm and down size with approved M-Sand including hand packing, ramming, watering including cost of all materials and labour with all lead and lift complete as per specifications. (Pg. No. 64 SOR Code A130A SR 2021-22 V- 5)

61.91

1672

103553.7615

... More
2.1.2 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8 (M5) Using 40 mm nominal size graded crushed coarse aggregates. (Vol-1, Pg. No.15, Item No. 2.1.2, SR 2021-22)

42.38

5466

231661.794

... More
2.2.2.1 - Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No.2.2.2.1 Vol-1 Pg No. 15 SR 2021-22)Additionalities for Formwork, Centering & Scaffolding for Isolated Foundation Upto Plinth 8% (I.No 1, 3rd Corrigendum and 2nd Addendum)

52.48

6780

355824.3712

... More
2.4.3 - Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No.2.4.3 Vol-1 Pg No. 17 SR 2021-22) Additionalities for Formwork, Centering & Scaffolding for Plinth beams of Building 50% (I.No 1.a, 3rd Corrigendum and 2nd Addendum)

11.67

9437

110134.458

... More
2.5.2 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No.2.5.2 Vol-1 Pg No. 17 SR 2021-22) Additionalities for Formwork, Centering & Scaffolding for Beams & Lintels of Building 60% (I.No 12, 3rd Corrigendum and 2nd Addendum)

23.22

10392

241313.3856

... More
2.5.2 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No.2.5.2 Vol-1 Pg No. 17 SR 2021-22) Additionalities for Formwork, Centering & Scaffolding for Columns 70% (I.No 8, 3rd Corrigendum and 2nd Addendum)

8.65

11042

95513.3865

... More
2.5.2 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No.2.5.2 Vol-1 Pg No. 17 SR 2021-22)Additionalities for Formwork, Centering & Scaffolding for Roof Slabs of Building 50% (I.No 13&14, 3rd Corrigendum and 2nd Addendum)

39.88

9742

388548.846

... More
14.1 - Supplying fitting & placing TMT bar reinforcement to superstructure complete as per Specifications ( Item No.14.1 Vol-3 Page No.103 SR 2021-22)

11.06

92661

1024835.637

... More
1.9 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.(Page No.7 Vol-1 .I No. 1.9 SR 2021-22)

783.8

214

167889.96

... More
5.4 - Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement: 6 coarse sand) (I No. 5.4, Vol-2 Pno . 9 SR 2021-22)

35.85

5619

201462.66

... More
6.32 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(I No. 6.32 Vol-2 P No. 17 SR 2021-22)

288.66

1255

362499.228

... More
6.34 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of allmaterials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Item no. 6.34 Vol-2 page no. 17 SR 2021-22)

71.21

987

70284.27

... More
11.34 A - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding7.12( Item No. 11.34 A Vol-2 Page no 85 SR 2021-22)

500.43

152

76190.4675

... More
8.1.1 - Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge For Ground Floor (Item No 8.1.1 Vol-2 page no 41 SR 2021-22 )

191.98

223

42936.327

... More
8.8 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge For Ground Floor (Item No 8.8 Vol-2 page no 42 SR 2021-22)

201.66

322

65005.101

... More
8.4.2 - Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge- For Ground Floor( Item No 8.4.2 Vol-2 page no 41 SR 2021-22 )

563.5

275

155018.85

... More
8.2.2 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge-For Ground Floor ( Item No 8.2.2 Vol-2 page no 41 SR 2021-22)

49.65

241

11990.475

... More
9.17.2 - Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete do - Size of Tile 600x600 mm(Item No 9.17.2 Vol-2 page no 61 SR 2021-22 )

131.94

1157

152667.774

... More
9.9 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete (Item No 9.9, Vol-2 Pg No- 60 SR 2021-22)

10.3

635

6543.075

... More
9.38 - Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (I.No.9.38 Vol-2 P.No.65 SR 2021-22)

32.42

1022

33158.2034

... More
9.24 - Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalentFor Ground Floor (item No. 9.24 Vol-2 page no 63 SR 2021-22)

69.85

3013

210492.975

... More
12.113.1 - Providing and fixing CI Nahani trap of approved make conforming to ISI specifications and construction of Cistern in M-15 as per directions (Rate is inclusive of cost of materials and fixtures and conveyance of materials to work spot). - 10cms x 7.5cms ( Item No 12.113.1, pg no 90 of SR 2018-19)

4

262

1050

... More
1.7 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 (Vol-5, Pg. No. 134, Item No. 1.7 SR 2021-22)

72

413

29786.4

... More
2.2 - Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN4, 110mm dia. (Sl.No.2.2, SOR CODE M020B Vol-5 Page 134)

15

284

4268.25

... More
2.4 - Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN4, 160mm dia. (Sl.No.2.4, SOR CODE M020D Vol-5 Page 134)

36

583

21016.8

... More
T130A - Constructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. (Sl.No.8, SOR CODE T130A Vol-5 Page 187)

2

4592

9185.4

... More
T130D - Constructing brick masonry chamber of internal dimension 450x300mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. (Sl.No.11, SOR CODE T130D Vol-5 Page 187)

2

3402

6804

... More
13.32.2 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.(1st Corrigendum Vol-2 I.No 13.32.2)

32

391

12532.8

... More
13.33.3 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (1st Corrigendum Vol-2 I.No 13.33.3)

45

313

14127.75

... More
13.33.6 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (1st Corrigendum Vol-2 I.No 13.33.6)

30

737

22113

... More
2.2.1 - Point wiring using copper wire without switch : Supplying and wiring adopting loop system in existing PVC Conduit / casing caping using copper PVC insulated multi strand 2*1.5Sqmm copper wire with a 6Amps flush type SP control switch shall be fixed on the exisisting plastic sheet/ gang box, the othe ind of the wires shall be terminated with sufficient loose length in a wood/ PVC round block. complete for each outlet. Short point upto 3mtr form tapping point to out let via switch (Refer KPWD SR 2019/20 Page 5 Sl. No. 2.2.1)

10

251

2510

... More
2.2.2 - Point wiring using copper wire without switch : Supplying and wiring adopting loop system in existing PVC Conduit / casing caping using copper PVC insulated multi strand 2*1.5Sqmm copper wire with a 6Amps flush type SP control switch shall be fixed on the exisisting plastic sheet/ gang box, the othe ind of the wires shall be terminated with sufficient loose length in a wood/ PVC round block. complete for each outlet. Medium point above 3Mtr upto 6mtr from tapping point to outlet via switch (Refer KPWD SR 2019/20 Page 5 Sl. No. 2.2.2)

30

361

10830

... More
2.2.3 - Point wiring using copper wire without switch : Supplying and wiring adopting loop system in existing PVC Conduit / casing caping using copper PVC insulated multi strand 2*1.5Sqmm copper wire with a 6Amps flush type SP control switch shall be fixed on the exisisting plastic sheet/ gang box, the othe ind of the wires shall be terminated with sufficient loose length in a wood/ PVC round block. complete for each outlet. Long point above 6 mtr upto 10mtr from tapping point to out let via switch (Refer KPWD SR 2019/20 Page 5 Sl. No. 2.2.3)

20

542

10840

... More
2.2.4 - Point wiring using copper wire without switch : Supplying and wiring adopting loop system in existing PVC Conduit / casing caping using copper PVC insulated multi strand 2*1.5Sqmm copper wire with a 6Amps flush type SP control switch shall be fixed on the exisisting plastic sheet/ gang box, the othe ind of the wires shall be terminated with sufficient loose length in a wood/ PVC round block. complete for each outlet. Two outlet in a row, above 3mtr upto 6mtr from tapping point to out let via switches .(Refer KPWD SR 2019/20 Page 5 Sl. No. 2.2.4)

2

671

1342

... More
1.2.1 - Concealed Conduit System : Supplying….mm dia 2mm 2.5mm thick heavy gauge PVC conduit pipe with suitable size bends, metal/ PVC junction boxes adhesive paste etc., and running before concreting the salb. The conduit should be tied to the reinforecement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with18 SWG GI fish wire wherever necessary. 19/20mm dia 2mm thick (Refer KPWD SR 2019/20 Page 2 Sl. No. 1.2.1)

450

61

27450

... More
1.2.2 - Concealed Conduit System : Supplying….mm dia 2mm 2.5mm thick heavy gauge PVC conduit pipe with suitable size bends, metal/ PVC junction boxes adhesive paste etc., and running before concreting the salb. The conduit should be tied to the reinforecement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with18 SWG GI fish wire wherever necessary. 25mm dia 2mm thick (Refer KPWD SR 2019/20 Page 2 Sl. No. 1.2.2)

300

70

21000

... More
1.3.1 - Groove cutting : Supplying.dia 2mm/2.5mm thick heavy gauge PVC Conduit pope with bends, metal junction boxes adhesive paste etc., and bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever neccessary. 19/20mm dia 2mm thick (Refer KPWD SR 2019/20 Page 2 Sl. No. 1.3.1)

150

75

11250

... More
1.3.1 - Groove cutting : Supplying.dia 2mm/2.5mm thick heavy gauge PVC Conduit pope with bends, metal junction boxes adhesive paste etc., and bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever neccessary. 25mm dia 2m thick (Refer KPWD SR 2019/20 Page 2 Sl. No. 1.3.1)

150

75

11250

... More
1.3.3 - Groove cutting : Supplying.dia 2mm/2.5mm thick heavy gauge PVC Conduit pope with bends, metal junction boxes adhesive paste etc., and bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever neccessary. 32mm dia 2.5mm thick (Refer KPWD SR 2019/20 Page 2 Sl. No. 1.3.3)

25

80

2000

... More
2.3.2 - Wiring for lighting/ power circuit using one of PVC insulated 1100v grade, multis and Copper conductor single core cable in open or concealed system of wiring. 1.5 sqmm (Refer KPWD SR 2019/20 Page 5 Sl. No. 2.3.2)

450

26

11700

... More
2.3.3 - Wiring for lighting/ power circuit using one of PVC insulated 1100v grade, multis and Copper conductor single core cable in open or concealed system of wiring. 2.5 sqmm (Refer KPWD SR 2019/20 Page 6 Sl. No. 2.3.3)

950

40

38000

... More
2.3.4 - Wiring for lighting/ power circuit using one of PVC insulated 1100v grade, multis and Copper conductor single core cable in open or concealed system of wiring. 4 sqmm (Refer KPWD SR 2019/20 Page 6 Sl. No. 2.3.4)

700

59

41300

... More
2.3.5 - Wiring for lighting/ power circuit using one of PVC insulated 1100v grade, multis and Copper conductor single core cable in open or concealed system of wiring.6 sqmm (Refer KPWD SR 2019/20 Page 6 Sl. No. 2.3.5)

250

87

21750

... More
1.5.1 - 19/20mm deep junction box (Refer KPWD SR 2019/20 Page 3 Sl. No. 1.5.1)

10

49

490

... More
1.5.2 - 25mm deep junction box (Refer KPWD SR 2014/15 Page 3 Sl. No. 1.5.2)

2

51

102

... More
1.12 - Supplying and fixing of Metal Fan Box with Round Hook. (Refer KPWD SR 2019/20 Page 3 Sl. No. 1.12)

15

163

2445

... More
3.4.1 - Supplying and flush mounting powder coated / galvanised metal box suitable for mountting modular switch plates. The box should be firmly mounted after due groove cutting in Brick/Stone/C.C. wall 1 - 3 Way (Refer KPWD SR 2019/20 Page 9 Sl. No.3.4.1)

55

123

6765

... More
3.4.3 - Supplying and flush mounting powder coated / galvanised metal box suitable for mountting modular switch plates. The box should be firmly mounted after due groove cutting in Brick/Stone/C.C. wall 6 Way (Refer KPWD SR 2019/20 Page 9 Sl. No.3.4.3)

10

212

2120

... More
3.4.4 - Supplying and flush mounting powder coated / galvanised metal box suitable for mountting modular switch plates. The box should be firmly mounted after due groove cutting in Brick/Stone/C.C. wall 8 Way (Refer KPWD SR 2019/20 Page 9 Sl. No.3.4.4)

10

250

2500

... More
3.4.5 - Supplying and flush mounting powder coated / galvanised metal box suitable for mountting modular switch plates. The box should be firmly mounted after due groove cutting in Brick/Stone/C.C. wall 10-12 Way (Refer KPWD SR 2019/20 Page 9 Sl. No.3.4.5)

5

325

1625

... More
3.4.6 - Supplying and flush mounting powder coated / galvanised metal box suitable for mountting modular switch plates. The box should be firmly mounted after due groove cutting in Brick/Stone/C.C. wall 16-18 Way (Refer KPWD SR 2019/20 Page 9 Sl. No.3.4.6)

1

355

355

... More
3.5.1 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module (Refer KPWD SR 2019/20 Page 9 Sl. No.3.5.1)

30

152

4560

... More
3.5.3 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ( Refer KPWD SR 2019/20 Page 9 Sl. No.3.5.3

10

244

2440

... More
3.5.4 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module (Refer KPWD SR 2019/20 Page 9 Sl. No.3.5.4)

10

302

3020

... More
3.5.5 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module (Refer KPWD SR 2019/20 Page 9 Sl. No.3.5.5)

5

363

1815

... More
3.5.6 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 16-18 Module (Refer KPWD SR 2019/20 Page 9 Sl. No.3.5.6)

1

402

402

... More
3.6.1 - Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293. 6A one way (Refer KPWD SR 2019/20 Page 10 Sl. No.3.6.1)

85

88

7480

... More
3.6.2 - Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293. 6A two way (Refer KPWD SR 2019/20 Page 10 Sl. No.3.6.2)

2

152

304

... More
3.6.3 - Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293. 6A three way socket. (Refer KPWD SR 2019/20 Page 10 Sl. No.3.6.3)

35

162

5670

... More
3.6.4 - Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293. Stepped Fan Regulator. (Refer KPWD SR 2019/20 Page 10 Sl. No.3.6.4)

15

313

4695

... More
3.6.8 - Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293. 16A one way switch.(Refer KPWD SR 2019/20 Page 10 Sl. No.3.6.8)

10

249

2490

... More
3.6.9 - Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293. 6Amps Bell Push switch .(Refer KPWD SR 2019/20 Page 10 Sl. No.3.6.9)

4

159

636

... More
3.6.11 - Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293. 6/16A Universal Socket.(Refer KPWD SR 2019/20 Page 10 Sl. No.3.6.11)

10

249

2490

... More
3.6.12 - Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293. TV/Telephone Socket .(Refer KPWD SR 2019/20 Page 10 Sl. No.3.6.12)

20

147

2940

... More
3.14.8 - Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293. 6Amps Bell Buzzer .(Refer KPWD SR 2019/20 Page 11 Sl. No.3.14.8)

4

123

492

... More
3.14.10 - Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293. 32A DP switch.(Refer KPWD SR 2019/20 Page 11 Sl. No.3.14.10)

6

108

648

... More
5.17.1 - Supplying and fixing miniature circuit breaker on existing MCB distribution board using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring confirming to IEC 60898. 5 - 32 Amps SP (Refer KPWD SR 2019/20 Page 27 Sl. No. 5.17.1)

15

523

7845

... More
5.17.7 - Supplying and fixing miniature circuit breaker on existing MCB distribution board using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring confirming to IEC 60898. 6-32 Amps TPN (Refer KPWD SR 2019/20 Page 27 Sl. No. 5.17.7)

1

1777

1777

... More
5.17.4 - Supplying and fixing miniature circuit breaker on existing MCB distribution board using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring confirming to IEC 60898. 6-32 Amps DP (Refer KPWD SR 2019/20 Page 27 Sl. No. 5.17.4)

1

909

909

... More
5.19.8 - Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board. 32Amps,4 Pole (Refer KPWD SR 2019/20 Page 28 Sl. No5.19.8)

1

4677

4677

... More
5.18.8 - Supplying and fixing regular MCB distribution board on wall/ flush mounting using required clamps, bolts, nuts, etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase/ single door with powder coated painting etc., complete. Made out of 14 SWG MS enclosure. 8 way TP & N (Refer KPWD SR 2014/15 Page 28 Sl. No. 5.18.11) 12 way SPN (Refer KPWD SR 2019/20 Page 28 Sl. No. 5.18.8)

1

1695

1695

... More
5.18.9 - Supplying and fixing regular MCB distribution board on wall/ flush mounting using required clamps, bolts, nuts, etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase/ single door with powder coated painting etc., complete. Made out of 14 SWG MS enclosure. 8 way TP & N (Refer KPWD SR 2014/15 Page 28 Sl. No. 5.18.11) 4 way TPN (Refer KPWD SR 2019/20 Page 28 Sl. No. 5.18.9)

1

2067

2067

... More
14.7.1 - Fixing all types and all capacities of flouroscent / false ceiling / spot light / CFL / LED fittings on the wall / ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required nos. of round blocks & clamps. On wall / ceiling / rafter / girders. (Refer KPWD SR 2019/20 Page 79 Sl. No.14.7.1)

35

110

3850

... More
14.8 - Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps ceiling rose, necessary length of 23/0.0076 inch PVC insulated twin twisted copper wire and wiring. (Refer KPWD SR 2019/20 Page 80 Sl. No.14.8)

15

150

2250

... More
14.5 - Fixing all types and Fixing halegen/LED/MH/svl/il/led FLOOD LIGHT FITTING on existing Pole /wall ceiling including lamps ,blts,nuts and wiring usiing suitable capacity wires (Refer KPWD SR 2019/20 Page 79 Sl. No.14.5)

2

175

350

... More
14.12 - Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and coloring to match the existing wall or brackets with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame if required.(Refer KPWD SR 2019/20 Page 80 Sl. No.14.12)

4

400

1600

... More
6.2 - Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipments on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proprotion of salt and charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and checknuts etc, the pipe shall have 16 through holes of 122 mm dia - (Refer KPWD SR 2019/20 Page 40 Sl. No. 6.2)

2

4150

8300

... More
6.3.1 - 25x3mm GI strip ( (Refer KPWD SR 2019/20 Page 40Sl. No. 6.3.1)

20

75

1500

... More
6.18.6 - 8 SWG copper wire (Refer KPWD SR 2019/20 Page 44 Sl. No. 6.18.6)

20

105

2100

... More
6.4.5 - Supplying 1.1KV LT UG cable having aluminium conductor PVC insulated, extruded inner sheathed, galvanised, steel strips : 3.5 core 25 sqmm (Refer KPWD SR 2019/20 Page 40 Sl. No.6.4.5)

100

180

18000

... More
6.5.2 - Labour charges for laying of 1.1 KV class UG cable existing trench GI pipe / stoneware pipe / on wall / on pole as required. In existing trench / duct In existing trench / duct 6 sq mm to 25 sqmm (Refer KPWD SR 2019/20 Page 41 Sl. No. 6.5.2)

100

15

1550

... More
6.11.3 - Supply and fixing of heavy duty cable glands suitable for UG Cables of 1.1 KV Class. (metal only) 32mm (Refer KPWD SR 2019/20 Page 42 Sl. No. 6.11.3

4

117

468

... More
6.17.6 - Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sq.mm (Refer KPWD SR 2019/20 Page 43 Sl. No. 6.17.6)

15

12

186.6

... More
6.61 - Digging of trench of 0.6m deep x 0.5m wide refilling the trench to the required ground level, consolidating etc. complete. In Soil.-ordinary (Refer KPWD SR 2019/20 Page 41Sl. No.6.61)

50

76

3800

... More
7.20.1 - Supply and laying double walled corrugated( DWC) HDPE Pipe with necessary connecting Sockets/ Coupling /Tees/Bends of same materials in existing trench as per IS 14930 part -II suitable for drawing under ground cables - 40 mm ( Page 63 Sl. No.7.20.1)

100

98

9800

... More
9.3 - Supply and drawing PVC Insulated Gas Injected Physical foam jellly flooded c-axial TV cable.RG.6 (Refer KPWD SR 2019/20 Page 54 Sl. No. 9.3)

300

35

10500

... More
9.2.2 - Supply and drawing PVCflexible One Pair Telephone unarmoured tinned copper cable (Refer KPWD SR 2019/20 Page 54 Sl. No. 9.2.2)

300

14

4350

... More
13.46 - Supply and fixing of 70-150watt lamp Holder (Refer KPWD SR 2019/20 Page 78 Sl. No. 13.46)

5

106

530

... More
14.1.2 - Supply and fixing of - mm dia class A pipe bracket up to 2mtrs using 32mm dia GI pipe (Refer KPWD SR 2019/20 Page 79 Sl. No. 14.1.2)

2

835

1670

... More
5.14.7 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. C curve ,indicator ON/OFF ,energy cross 3 with short circuit breaking capacity of 10k and complete wiring as required 63 /100Amps ,25KA, FP for Panel EB Incomer (Refer KPWD SR 2019/20 Page 27 Sl. No. 5.14.7)

1

8265

8265

... More
5.17.7 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. C curve ,indicator ON/OFF ,energy cross 3 with short circuit breaking capacity of 10k and complete wiring as required 6-32 Amps TPN (Refer KPWD SR 2019/20 Page 27 Sl. No. 5.17.7)

1

1777

1777

... More
5.9.2 - Supplying and fixing HRC Fuse unit base on existing switch/panel board - Up to 63A (Refer KPWD SR 2019/20 Page 25 Sl. No.5.9.2)

1

270

270

... More
5.40.1 - Supplying 100. Amps rated 3 phase with neutral bus bar using requirement capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/ DMC insulator which are mounted on powder coated 40*6mm M.S flat frame work in exisisting panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. : 100Amps 4x30x6mm Alluminium Strips - 100Amps , 4x50x10xmm AL strips (Refer KPWD SR 2019/20 Page 30 Sl. No. 5.40.1)

2

2214

4428

... More
5.40.2 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. - 50x50x6mm (Refer KPWD SR 2019/20 Page 30 Sl. No. 5.40.2)

5

3078

15390

... More
5.42.1 - Fabricating supplying and mounting MS box made out 14 SWG suitable for floor/ wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with glad and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled meta paint etc., complete. (Refer KPWD SR 2019/20 Page 30 Sl. No. 5.42.1) (Approximate size 0.6 Mtr x0.6 Mtr x0.45mtr)

35000

-

15050

... More
5.30 - Supplying of and fixing Trivector Meter suitable of for operation suitable for 5 to 20A single phase opeartion class-1 ,accuracy with temper proff energy meter (Refer KPWD SR 2019/20 Page 29 Sl. No. 5.30)

1

1242

1242

... More
5.38 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C. .(Refer KPWD SR 2019/20Page 29 Sl. No.5.38)

3

464

1392

... More
5.11.1 - Supply of onload Change Over switches 4 poles, AC -23A duty ,415V AC supply - 63A (Refer KPWD SR 2019/20 Page 25 Sl. No. 5.11.1)

1

5185

5185

... More
5.21 - Supplying and fixing of and wiring earth leakage relay with core balanced Current Transformer suitable for single phase 50Hz AC with latest microcontroller based ,digital readout (Refer KPWD SR 2019/20 Page 28 Sl. No.5.21)

1

8316

8316

... More
12.2.1 - Supplying - feet - PVC batten with integrated LED tube - watt with high quality deffuser with life of 25000 burning hours &70% lumen maintenence with CRI .2 year warranty againest any manufacturing defect - LED light fitting 1 x2' -9/10watt - (Refer KPWD SR 2019/20 Page 64 Sl. No.12.2.1) - Common area

10

239

2390

... More
12.2.2 - Supplying - feet - PVC batten with integrated LED tube - watt with high quality deffuser with life of 25000 burning hours &70% lumen maintenence with CRI .2 year warranty againest any manufacturing defect - LED light fitting 1 x4' -20/22watt - (Refer KPWD SR 2019/20 Page 64 Sl. No.12.2.2)

30

422

12660

... More
7.3.1 - Supplying 48" Sweep (1200mm)capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles, Single phase AC supply conforming ot ISS-374-1979 and with double ball bearing system. (Refer KPWD SR 2019/20 Page 46 Sl. No.7.3.1)

15

2090

31350

... More
12.8.3 - Supply of LED Streetlight 70 watts. (Refer KPWD SR 2019/20 Page 67 Sl. No. 12.8.3)

2

5480

10960

... More
12.11.5 - Supply and fixing of LED Bulb - 12 watt (Refer KPWD SR 2019/20 Page 68 Sl. No. 12.11.5)

5

165

825

... More
7.1 - Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable for operate on 230V 50Hz, AC supply. (Refer KPWD SR 2019/20 Page 46 Sl. No.7.1)

4

1200

4800



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.