Indian Institute Of Science Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Indian Institute Of Science - IISC Tender

Works
Electrical Goods and Equipments
Electrical and Electronics
Eprocure
Opening Date16 Feb 2023
Closing Date23 Mar 2023
Tender Amount₹ 3,71,43,349 
Notes
Download

Costs

Summary

Providing High Mast Flood Lighting For Cricket Football And Hockey Grounds In Gymkhana At

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, Installation, Testing & Commissioning of external power lift man rider unit for accessing the head frame suitable for 16 Mtr High Mast. The unit shall be suitable for safe load carrying capacity of 300kg with climb speed not exceeding 9m/min.

1

-

-

... More
Supply, Installation, Testing & Commissioning of external power lift man rider unit for accessing the head frame suitable for 20 Mtr High Mast. The unit shall be suitable for safe load carrying capacity of 300kg with climb speed not exceeding 9m/min.

1

-

-

... More
Supply, Installation, Testing & Commissioning of external power lift man rider unit for accessing the head frame suitable for 30 Mtr High Mast. The unit shall be suitable for safe load carrying capacity of 300kg with climb speed not exceeding 9m/min.

1

-

-

... More
Earth work excavation for Foundation by mechanical means for allworks & depth upto 3 m, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling theexcavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth up to 3.5m

664

-

-

... More
Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications.

664

-

-

... More
PCC in Bed 1:4:8 @ depth of 3m from GL of thickness 150mm.OPC @ 180 Kgs, 40mm & down size graded Granite metal coarse aggregate @0.85Cum & fine aggregates @0.57 cum machine mixed concrete laid in layers not exceeding 75 mm thick & well compacted.(1 cement :4 sand: 8 Aggregate) Providing cement mortar of mix 1:4:8 (1 cement :4 sand: 8 Aggregate) including cost of all materials, formowrk, centering, scafolding labour charges, HOM of machinery complete as per specifications. Specification No. KBS 0.5-1.2. All works complete as per the drawing, technical specification and direction of the Engineer in-charge.

17.44

-

-

... More
Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Designincluding cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)

5088

-

-

... More
Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications including cost of all materials, formowrk, centering, scafolding labour charges. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.

110.88

-

-

... More
Supply, Installation,Testing and Commissioning of Electrical feeder pillar for high mast with all accessories including required foundation as per the SLD enclosed. (Refer Technical Specifications Section:11)

16

-

-

... More
Supply, installation, testing and commissioning of of LED Floodlight with system power consumption of the following wattage ratings. Housing made of die cast aluminium for efficient thermal management, sturdiness & corrosion resistance. SS hardware, silicon gasket for IP66 protection, IK07 rated and operating ambient temperature of -10°C to +45°C. Built-in, IP 67 potted electronic LED driver with APFC, 140-270V operating voltage, PF≥0.95, THD ≤10%, Surge Voltage Protection up to 10 kV With Built In SPD, other safety test as per IS 15885 Part-2/Sec 13 and CISPR 15 complied. High efficiency long life LED module mounted on MCPCB with average life shall be L70 B50 50000 hrs, LED efficiency145 LPW, system efficiency ≥ 120 LPW, CRI70 and viewing angle of 120deg for better uniformity. UV Stabilized symmetrical distribution polycarbonate lens. Tempered protective toughened glass 4 mm, thermal shock and impact resistant (IK-07) fixed to the housing with aluminium frame and SS screws. Wall or surface mounting using adjustable MS cradle of thickness 4 mm with SS angular dial is provided with the fixture for precise angular mounting of luminaire. LM 79 report as tested in NABL certified lab & LM 80 report from LED chip manufacturer. Luminaire manufacturers should have in-house facility accredited by NABL & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die-cast housing/ Body part. Warranty of 5 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer. (Make: Crompton/Philips/Wipro/Panasonic/Havells/Lighting Technologies) HOCKEY GROUND 500W LED Flood light with 10 deg beam angle

48

-

-

... More
FOOT BALL GROUND a) 500W LED Flood light with 30 deg beam angle

8

-

-

... More
b) 500W LED Flood light with 10 deg beam angle

56

-

-

... More
CRICKET GROUND a) 960W LED Flood light with 30 deg beam angle

16

-

-

... More
b) 960W LED Flood light with 10 deg beam angle

120

-

-

... More
Supply of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. a) 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)

450

-

-

... More
b) 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm)

280

-

-

... More
c) 25 Sqmm, 3.5 Core, (12 GI Strips - 4 x 0.8 mm)

2400

-

-

... More
d) 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm)

300

-

-

... More
e) 3.5 core x 240 sqmm

1400

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. a) Upto 35 sq. mm

3130

-

-

... More
b) Above 35 sq. mm and upto 95 sqmm

300

-

-

... More
c)Above 185 sq. mm and upto 400 sqmm

1400

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. a) Upto 35 sq. mm

15

-

-

... More
b) Above 35 sq. mm and upto 95 sqmm

15

-

-

... More
c) Above 185 sq. mm and upto 400 sqmm

15

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. a) Upto 35 sq. mm (clamped with 1mm thick saddle)

5

-

-

... More
b) Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

5

-

-

... More
c)Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

5

-

-

... More
Cutting road surfaces for pipeline trenches and disposing of excavated stuff as directed including barricading, danger lighting etc in the classifications for cutting asphalt road surface by machine cutting to demarcate the trench width of the surface.

35

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. a) 3½ X 240 sq. mm (62mm)

6

-

-

... More
b) 3½ X 120 sq. mm (45mm)

6

-

-

... More
c) 3½ X 50 sq. mm (35mm)

6

-

-

... More
d) 3½ X 25 sq. mm (28mm)

32

-

-

... More
e) 4 X 16 sq. mm (28mm)

16

-

-

... More
f) 4 X 10 sq. mm (25mm)

48

-

-

... More
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.)

100

-

-

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.

32

-

-

... More
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

200

-

-

... More
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. a) 500-630 Amps FP 50 kA

1

-

-

... More
b) 250Amps FP 35kA

2

-

-

... More
c) 125Amps FP 25kA

3

-

-

... More
d) 100Amps FP 25kA

1

-

-

... More
Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. a) 6-32 A TPN

16

-

-

... More
b) 50-63Amps TPN

6

-

-

... More
Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy.

1

-

-

... More
Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with tape wound.

3

-

-

... More
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v DC.

3

-

-

... More
Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.

1

-

-

... More
Supplying ......... amps rated 3 phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. a) 100 Amps 4x30x6mm Aluminum Strips

6

-

-

... More
b) 250 Amps 4x30x10mm Aluminum Strips

3

-

-

... More
c) 600Amps 4x75x10mm Aluminium Strips

5

-

-

... More
Fabricating supplying and mounting MS box made out 16 SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7 tanks treatment with powder coated paint and finally finished with approved colour etc., complete.

327820

-

-

... More
Supplying and fixing angle iron framework fabricated out of M.S. angle iron and M.S. flat of size 75x75x6mm with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.

18

-

-

... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. a) 4 Sq.mm

150

-

-

... More
b) 6 Sq.mm

120

-

-

... More
c) 10 Sq.mm

75

-

-

... More
d) 16 Sq.mm

100

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.