Indian Institute Of Science Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Indian Institute Of Science - IISC Tender

Works
Energy, Oil and Gas
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date16 Aug 2022
Closing Date10 Sep 2022
Tender Amount₹ 6,00,00,000 
Notes
Download

Costs

Summary

Supply Installation Testing And

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
EXHAUST PIPE SUPPORT - Design,Supply,testing & comissioning of MS structure support for DG stack with double coated epoxy paint and suitable for 4 x 1250kVA DG sets. Structure shall be suitable for wind pressure as per site condition.Cost shall include other accessoris,ladder with safety guards,foundation bolts ,necessary supports etc with raincawl on top.(DG set Exhaust pipe supporting structure shall comply all requirements of local authorities) Steel Supports - Supply, fabrication and installation of MS structural supports including welding, bolting, riveting, supply of necessary anchor bolts and grouting etc, supply of paint and applying one coat of anti rust primer and two finished coats of approved synthetic enamel paint including breaking walls, floors etc. for structures as required including supply of all GI hardware materials, including all labour and materials as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Any item weighting upto 1Kg or less shall neither be measured nor paid)

30000

-

-

... More
LT BUSDUCTS- Design, Engineering, Manufacture, Supply, Commisioning, Documentation of following LT sandwitch BUSDUCT with integral earth including submission of relevant data, inspection and testing at factory works, packing, transportation from MANUFACTURER works to site, including transportation from store/yard to site at the place of installation, handling equipment at site, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor,minor civil works, interconnection of shipping sections, installation of bus duct support (fixing to wall/column/ceiling or steel structures) and aligning, levelling, grouting, testing, and calibration of equipment, including all labour and materials, as per approved drawings, specification of this tender and directions of Engineer-in-charge along with its necessary accessories. Out door portion shall be supplied with rain hood. The bus duct shall be with IP 55 without any additional enclosure. 415V 2000A, 50kA for 1 sec,TPN Aluminium Sandwich Busduct between DG to DG synchronization panel with below mentioned items 90 deg horizontal bend 90 deg vertical bend Wall cross over unit Terminal box at switchgear end including seal off bushing and Aluminium flexible and required accessories. Hot dip galvanised steel Bus duct support required. Supports shall be as per site requirement Phase cross over chamber (if required) Any other accessories like earthing conductor,flexibles,inspection cover, Horizontal/Vertical length

165

-

-

... More
DG SYNCHRONISING PANELS- Supply, erection, testing and commissioning of 415V, 3 phase 4 wire 50 c/s, fully compartmentalized cubical type, as per the standards IEC61439-1&2 as tested assembly (TTA) ,tested for impulse voltage 8 KV,IP 42 fabricated CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having required capacity extensible type FP aluminium alloy bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 50KA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, Form of separation shall be form 4b with metallic separation only entire panel shall have a common copper earth bar of size 50 mm x 6 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al/Cu. bus bars, interconnection, interlocking between feeders etc., Annuntiation window requirement shall be as per SLD. with indication lamps, push buttons necessary accessories, complete with following incoming and outgoing switchgears with protection and metering etc. as per specification and schematic diagram including provision to be made for interfacing with BMS etc. complete as required with incoming & outgoing bus-duct entry from top, wiring with 2.5sq. mm. PVC insulated copper conductor , cable alleys, cable gland i/c providing following switch gears All ACBs should have Ics=Icu=Icw for 1 sec All MCCBs shall be rating for 50kA (Ics=Icu). All MCCBs above 63A should be provided with Copper Spreader Terminals Marshalling Bay To Be Provided for BMS Operation Approval shall be taken for each panel before fabrication. For cable sizes refer to the cable schedule attached. contractor to consider the termination requirement as per the cable sizes furnished in the cable schedule. If any additional termination box is required the same shll be considered by contractor in the panel cost itself. The fault level of the component shall be same as the bus bar fault level indicated. The panel shall be designed to suit to the site condition. If any U shape/L shape panels required as per site requirement, contractor to consider all required dummy panel, adaptor boxes, bus bar extension, other accessories, etc. in the panel cost itself. All the cost required for BMS integration like cable,control modules,converters, connectors etc as per the attached scheme shall be included in panel cost itself. The scope shall include relay coordination study. ON / OFF / TRIP status for all the incomming breakers (ACB, MCCB, MCB, MPCB, RCBO) & meter parameter from all main panel (Listed Below) to be provided through modbus IP output (PLC) to connect to BMS through ethernet switch located within one of the panels in each electrical room. All cost towards cable, ethernet switch, BMS interface module, etc shall be covered in the panel cost itself. Any details idicated in SLD and specification is also needs to be consiedered for panel cost.Any details idicated in SLD and specification is also needs to be consiedered for panel cost. DG Synchronising Panel -1, 2 @ SS Incomer 2000A FP EDO ACB with microprocessor based O/L, S/C and E/F - 2 Nos. Suitable for Bus Duct termination For indication lamps please refer to SLD Analog Ameter and voltmeter with selector switch - 3 set. SPD type II, 50KA, FP - 3 nos. Multi Function Meter with RS 485 port.- 3 nos. C.T. 2000/1A, CLASS 0.5 10VA- 2 set. C.T. 2000/1A, CLASS PS- 2 set. Line PT : 415V/v3/110V/v3, Cl.1, 50VA - 3 set Bus PT : 415V/v3/110V/v3, Cl.1, 50VA - 3 set 4000A TPN AL busbar 1sec (50kA) Outgoing : 50kA ALL ACB / MCCB 4000A FP MDO ACB microprocessor based with O/L, S/C & E/F Protection - 2 nos. C.T. 4000/1A, CLASS 0.5 10VA- 3 sets Multi Function Meter with RS 485 port.- 2 nos. For indication lamps ,numeric relays, please refer to SLD All incoming and Outgoing breaker should be communicable for status monitoring. All required relay and synchronization controller shall be provided in the synchronization & control panel. Control & Operation of DG breaker panel shall be only from synchronization & Control panel.Please refer to single line diagram and technical specification for more details Supply, Installation, testing & commissioning of Inert type Novec-1230/FM200 Fire Detection Tube based Gas suppression system for electrical panel. It includes all the require accessories/equipments to complete the panel protection, as per detail specification.

2

-

-

... More
LT Power , Control Cable - Supply, installation, testing and commissioning of PVC/XLPE insulated, FRLS PVC outer sheathed Control/Arm.Power cables of grade (650/1100V grade) along with required termination for DG system as per scope of work .Installation in form of Horizontal and vertical laying of armoured cables of required sizes in pre excavated cable trench /existing concrete trenches / cable trays, hume pipe/cable Gallery supported on structure/pull through pipes dewatering if required using own pumps including pipes, supply and fixing of Aluminium strip number tags, supply and fixing of GI saddles and saddle bars, etc. including transportation from owners stores to site. Unpacking, with all labour and material as per specification of this tender and directions of Engineer-in-Charge.The cost shall include the neccesary termination along with glands. a) 16 core 2.5 sq.mm Cu

350

-

-

... More
b) 6 core 2.5 sq.mm Cu

250

-

-

... More
c) 4 core 2.5 sq.mm Shielded cable

400

-

-

... More
d) 4 core 2.5 sq.mm Cu

300

-

-

... More
e) 2 core 4 sq.mm Cu

300

-

-

... More
f) 2 core 2.5 sqmm Cu

150

-

-

... More
g) 4 core 4 sq.mm Cu

80

-

-

... More
h) 3 core 2.5 sq.mm Cu

300

-

-

... More
i) 3 core 2.5 sq.mm Shielded cable

200

-

-

... More
j) 3C X 6sqmm. Cu Arm cable

100

-

-

... More
k) 3C X 4sqmm. Cu Arm cable

150

-

-

... More
LT Cable Terminations and Cable Joint kits -Supply & Installation of heat shrinkable end termination kits and making End Terminations for XLPE insulated LT power & Control cables 1100V grade of following sizes including double Compression Gland of brass type, Aluminium lugs for Aluminium Cables and Bimetallic lugs at tranformer end,including supply and fixing as per specification and direction of engineer in charge a) 16 core 2.5 sq.mm Cu

20

-

-

... More
b) 6 core 2.5 sq.mm Cu

20

-

-

... More
c) 4 core 2.5 sq.mm Shielded cable

16

-

-

... More
d) 4 core 2.5 sq.mm Cu

16

-

-

... More
e) 2 core 4 sq.mm Cu

16

-

-

... More
f) 2 core 2.5 sqmm Cu

20

-

-

... More
g) 4 core 4 sq.mm Cu

8

-

-

... More
h) 3 core 2.5 sq.mm Cu

16

-

-

... More
i) 3 core 2.5 sq.mm Shielded cable

16

-

-

... More
j) 3C X 6sqmm. Cu Arm cable

10

-

-

... More
k) 3C X 4sqmm. Cu Arm cable

10

-

-

... More
Earthing System - Supply, installation and connection of following required GI & CU earthing strip along the buildings, cable trenches or cable trays including welding at joints(Brazing for copper), providing anti-corrosive paint or bitumen for welded portion, clamping and necessary hardware for connecting, etc., including all labour and materials,as per specification of this tender and directions of Engineer-in-Charge a) 50x 6 GI Flat

150

-

-

... More
b) 25 x 6GI Flat

200

-

-

... More
c) 25 x 3 GI Flat

50

-

-

... More
LIGHTNING PROTECTION SYSTEM - Supply, installation, testing & laying of lightning protection system consisting of down conductor upto test link with all necessary clamps, connectors and other accessories required to complete the stack lightning protection.Scope includes Earth pits,test link,Flat 25X3 mm thick GI from test link to earth electrode directly in ground with all required clamps and connectors.Cost shall include supply & installation of LED type twin aviation lamp, DB, required cabling and other accesories

1

-

-

... More
STATUTORY APPROVALS- The cost of obtaining all statutaty clearances from all statutory authority like PCB , Electrical Inspectorate, CCOE & Local authority etc. shall be included.However statutory payments in the name of client shall be reembersed separately after producing invoice for the same.

1

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanization thickness not less than 50 microns) in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders or supported with Angle iron in Trenches including G.I. bolts & nuts, etc. as required a) Ladder type Cable Tray - 300 mm

80

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. a)300 mm width X 50 mm depth X 1.6 mm thickness

80

-

-

... More
b)150 mm width X 50 mm depth X 1.6 mm thickness

80

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.