Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
Indian Institute Of Science - IISC Tender
Paints and Enamels
Civil Works Others
Eprocure
Opening Date20 Nov 2024
Closing Soon27 Nov 2024
Tender AmountRefer Documents
Costs
EMD
Refer DocumentsDocument Cost
Refer DocumentsTender Fee
Refer Documents
Summary
External And Internal Painting Watersupply Entrance Cobble Stone Pathway With Mangalore Tiles Roof Glass Door Collapsible Steel Shutters And Other Allied
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_IISC_835686_1Tender No
IISc/WORK-09/TSC-05/2024-25Tender Authority
Indian Institute Of Science ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking to the appropriate disposal area as per direction of Engineer-in-charge Thickness above 10 mm up to 25 mm
50
-
-
Dismantling of flushing cistern of all types (C.I./PVC/Vitreous China) including stacking of useful materials near the site and disposal of unserviceable materials to the appropriate disposal area as per direction of Engineer-in-charge.
1
-
-
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material to the appropriate disposal area as per direction of Engineer-in-charge.
2
-
-
Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.
12
-
-
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material to the appropriate disposal area as per direction of Engineer-in-charge. G.S. Sheet
28
-
-
Labour charges for works of loading and unloading works and for semi skilled ( 2.Cleaning of existing floor area 3.shifting of Dismantling debris 4.Removal of old tables, furnitures 5.Removal of mesh )
4
-
-
Removal of Unserviceable Soil materials/debris,concrete with Disposal upto a Suitable distance as directed by the Engineer incharge of work outside the IISc campus(Up to BBMP Iimits)(All dismantled materials and unused materials) For Tractor-Trolley
4
-
-
Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. All kinds of soils. Depth upto 1.50 m
1
-
-
Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications
1
-
-
Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.
25
-
-
Providing general disinfection services, spraying of insecticide and pesticide inside and outside the building (flies, bedbugs,lizards, cockroaches, spiders caterpillars etc., including cost of materials labour lead, usage charges of equipments etc., complete.
5
-
-
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates
5.8
-
-
Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.
3
-
-
Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.
14
-
-
Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(SSm wall)
35
-
-
Providing 15 mm cement plaster on the rough side of single or halfbrick wall of mix :1:6 (1 cement: 6 fine sand) including rounding offcorners wherever required smooth rendering, providing and removing scaffolding, including cost of materials,scafolding labour, curing complete as perspecifications and as per directions of Engineer-in-charge.
15
-
-
Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 m² and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge. (For Roof, Wall and Water Tanks)
10
-
-
Removing white or colour wash by scrapping and sand papering and pre paring the surface smooth including necessary repairs to scratches etc. complete as per specifications and as per directions of Engineer in charge
525
-
-
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.
85
-
-
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 g/L, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge
525
-
-
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge
49
-
-
Finishing walls with Acrylic Smooth exterior paint of required shade : Old work (Two coat applied @ 1.67 ltr/ 10 m²) on existing cement paint surface including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer_x0002_in-charge.
440
-
-
Cutting out cracks of roof terrace to V - section cleaning out and filling solidly with a hot mixure of bitumen and clean dry sand 1:1 by weight including cost of materials, labour, complete as per specifications.
50
-
-
Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2 l/per m2, having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 l/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.(Mangalore tiles above Height up to 10m)
5
-
-
Providing and laying 60mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Cycle Tracks & Pedestrian Footpaths of approved shape and colour, laid in required pattern and including over 30mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-incharge. (WMM/WBM Base to be paid separately if necessary as per relevant technical specification)
36
-
-
Cleaning and washing of Acid wash for decorated wall /floor surface with soap, soda and water including cost of materials, labour, complete as per specifications.
170
-
-
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg/m2, including pointing in white cement mixed with pigment of matching shade complete.
1.5
-
-
Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
560
-
-
Supplying and fixing new Mangalore tiles on with steel reepers
64
-
-
Providing Mangalore Ridge tiles set in C.M. 1:2 and pointed with C.M. 1:2
20
-
-
Taking out existing wooden door shutter/Window, repair by cutting, painting etc. and refixing of repaired door shutters/window to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge.
2
-
-
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with 4.0 mm thick glass panes including cost of materials, labour,usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge
2
-
-
Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.
1
-
-
Melamine polishing on wood work (one coat) including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
20
-
-
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc. to be paid separately) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
3.6
-
-
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
3.8
-
-
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid.
1
-
-
Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete forPVC pipes 75mm dia., 6 kg/sqcm & class 3
3
-
-
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 20 mm nominal dia Pipes
10
-
-
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal dia Pipes
28
-
-
Labour charges for works of plumber and carpenter and etc for Door repairs and fixing of plumbing fixtures (shifting of existing tank,fixing of old pipe lines and serviceing )
3
-
-
Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.25mm nominal bore, weighing not less than 62 g
2
-
-
Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendment7 5 mm dia PVC BEND
7
-
-
Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc PVC pipes 110mm dia., 6kg/sqcm & class 3
3
-
-
Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.
a) a) 19/20 mm dia 2 mm thick
20
-
-
b) 25 mm dia 2 mm thick
80
-
-
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
a)3 Module
1
-
-
b) 8 Module
1
-
-
c) 12 Module
1
-
-
Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. a)3 Way
4
-
-
b) 8 Module
1
-
-
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
a)3 Module
5
-
-
b) 8 Module
2
-
-
c) 12 Module
2
-
-
Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
a) 1.5 mm²
50
-
-
b) 2.5 mm²
250
-
-
c) 4 mm²
250
-
-
d) 6 mm²
150
-
-
e) 16 mm²
80
-
-
Supplying and drawing 3C x 4 mm2 flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to 13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.
45
-
-
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
a) 6A Switch
5
-
-
b) 6A socket
3
-
-
c) 16A Switch
2
-
-
d) 6/16A Universal Socket
2
-
-
e) Stepped Fan Regulator Two Module
2
-
-
Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm .... etc. as required. a) 25 mm
20
-
-
b) 50 mm
120
-
-
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.
a) Short point upto 3m from tapping point to out let via switch
10
-
-
b) Medium point above 3m upto 6m from tapping point to out let via switch
5
-
-
Supply and fixing of Surface mounting non integral type LED modular down light 2'x2', 36W luminaire comprising of pressure decast/ extruded aluminium housing, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.
12
-
-
Supply of round/square, recess/surface mounted rolling type LED Down light with 18 W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition
1
-
-
Supplying of ......feet -PVC Batten with integrated LED Light ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. a) LED light fitting 1 x 4' - 20W
12
-
-
b) LED light fitting 1 x 2' - 9/10 W
1
-
-
Supplying and fixing of Ceiling Fan with Capacity rating As per guidelineof BEE 5star ratingand IS:374/19 and also comply with IS:1709/ 1984 with latest amendment, Rated voltage 220V/50Hz, Rated power upto 35W+/-10%, Rated current As per IS:374/19 with remote control operation, Rated power factor 0.9 lagging (min), Rated speed 350+/-10% RPM, Rated air delivery 210+/-10% Cubic Meter Minimum, Rated service value 6.2 CMM/W, Three Blades of blade leaf 1.05mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top6202, Bottom 6201, as per IS specification, Motor winding. Temprise Shall not exceed 75deg Cover and ambient of 400C by resistance method at 245V, Insulation resistance Shall not be less than Two Mega Ohms (2MOhms), Leakage current Should not exceed 210 Micro Amp, Power input, W & current, Air Delivery & Fan Speedas per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans)
4
-
-
Supply, loading, transportation and unloading of following 1.1 kV, XLPE, PVC exutruted Inner Seath Aluminium Armoured LT UG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975
a) 3.5 Core x 35 Sqmm
30
-
-
b) 3.5 Core x 50 Sqmm
30
-
-
c) 3.5 Core x 185 Sqmm
60
-
-
Supplying and laying of following strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. 25 x 6 mm GI strip
60
-
-
Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. a) 6 A SP
10
-
-
b) 16A SP
4
-
-
c) 25A SP
2
-
-
d) 32 A DP
2
-
-
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with adjustable Microprocessor release shall have Earth Fault as per IS/IEC60947-2. (Icu=100%lcs).In 4P MCCB, all Poles should have protection for Short- Cicrcuit / OverLoad. For Microprocessor MCCBS Facility for segregating Priority and Non - Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.
a) 100 A, 25 kA TP
2
-
-
b) 125 A, 25 kA TP
2
-
-
c) 250 A 36 kA TPN
2
-
-
Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection, RS-485 and completely wired as required with communication Port and Class 0.5s accuracy
1
-
-
Supplying, fixing and wiring 250/5A 5VA burden
Current Transformer Class 0.5 accuracy with Tape Wound.
3
-
-
Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for 415V, 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.
1
-
-
Supplying and fixing of LED type panel board indicating
lamp with required colour suitable for 230/440VAC. 50 Hz or 12/24V D.C. (R,Y,B, ON, OFF & Trip for Incomer)
1
-
-
Fabricating supplying and mounting MS box suitable for outdoor application IP54 made out 16 SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete
97000
-
-
Supplying ---- A rated 3phase with neutral bus bar using
required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic /FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete
a) 400 A, 4 x 50 x 10 mm Aluminium Strips
4
-
-
b) 250 A, 4 x 30 x 10 mm Aluminium Strips
2
-
-
Supplying and fixing angle iron framework fabricated out of M.S. angle iron and M.S. flat of size 75x75x6mm with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.
7
-
-
Supplying, installation, testing and commissioning of horizontal type of Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc. complete. 2.00 HP/1.5KW , 6 STG
1
-
-
Supply, installing,testing and commissioning COMMON control panel
consisting of the following INCOMING:1 No set of Phase indicating
lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog
Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING
for Main Electrical Pump: 1 No. MCB 1 No. DOL Starter suitable for respective 2 HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter
1
-
-
Supplying and drawing UTP-CAT 6E LAN cable.
250
-
-
Supplying, fixing and connection of RJ-45 I/O Socket with termination of CAT 6 cable.
5
-
-
Supplying & Fixing of Patch panel for LAN cabling. 16 Port 10/100/1000 patch panel and making connection of all Cable with RJ 45 connector.
1
-
-
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
a) Upto 35 sq. mm and (clamped with 1mm thick saddle)
30
-
-
b) Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
30
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 95 sq. mm and upto 185 sq. mm
60
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
a) 3.5C X 35 sq. mm
2
-
-
b) 3.5C X 50 sq. mm
2
-
-
c) 3.5C x 185 Sq.mm
2
-
-
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
40
-
-
Supplying and fixing cable route marker with 10 cm X 10cm X5mm thick G.I. plate with inscription there on, bolted / welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
3
-
-
Providing and fixing 63 A,16KA,TP MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
3
-
-
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
1
-
-
Labour charges for Electrician, releasing and refixing of existing DB, Switch board, light fixtures, LAN cable, conduit pipe etc.,
5
-
-
Supply and fixing of DLP PVC Trunking 150 x 50 mm Bodies
25
-
-
Supply and fixing of DLP PVC Trunking Full cover width 130 mm
25
-
-
Supply and fixing of Fixed Internal/External Angle/ Flat angle Include the 2 components for the top and bottom of the trunking on which the flexible cover is fitted,
6
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%