Indian Institute Of Science Tender
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
Indian Institute Of Science - IISC Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date21 Mar 2023
Closing Date10 Apr 2023
Tender Amount₹ 21,26,576
Costs
EMD
₹ 31,898Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_IISC_746076_1Bid Award Id
ViewTender No
IISc/Tender-ELE-5/2022-23Tender Authority
Indian Institute Of Science ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy.
1
-
-
Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound.
3
-
-
Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.
1
-
-
Supplying and fixing of Shunt trip suitable for MCCB.CBCT.
1
-
-
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C.
3
-
-
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws,bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.100Amps 25kA. FOUR POLE
6
-
-
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws,bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.250Amps 35kA. FOUR POLE
2
-
-
1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 240 Sqmm, 3.5 Core, (30 GI Strips - 4 x 0.8 mm)
10
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated andPVC sheathed / XLPE aluminium conductor cable of 1.1 KV gradeas required.3.5CX 240 sq. mm (62mm)
3
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated andPVC sheathed / XLPE aluminium conductor cable of 1.1 KV gradeas required.3.5CX 35 sq. mm (32mm)
3
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated andPVC sheathed / XLPE aluminium conductor cable of 1.1 KV gradeas required.3.5C X 50 sq. mm (35mm)
3
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated andPVC sheathed / XLPE aluminium conductor cable of 1.1 KV gradeas required.4 X 10 sq. mm (25mm)
12
-
-
Providing and laying in position Reinforced cementconcrete for allFoundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machinemixed with super plasticizers laid in finished layers, well compactedusing needle vibrators, including all lead & lifts,cost of all materials,quality confirming to the requirements of relevant IS codes ,labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarseaggregates
1
-
-
Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply.(Open Execution).250Amps
1
-
-
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.50x50x6mm
18
-
-
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm
1591
-
-
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.5 sqmm
2120
-
-
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.4 sqmm
1381
-
-
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.6 sqmm
880
-
-
Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts,nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.8 Way SP & N
4
-
-
Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts,nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.12 Way TP & N
3
-
-
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32Amps SP
45
-
-
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32Amps DP
4
-
-
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.50-63 A TPN
12
-
-
Supplying of ......feet - PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fighting 1 x4'- 20/22 w
98
-
-
Supplying heavy gauge PVC conduit pipe …….dia .......mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws19/20MM, Dia 2 mm thick
350
-
-
Supplying heavy gauge PVC conduit pipe …….dia .......mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws25MM, Dia 2 mm thick
301
-
-
Supplying heavy gauge PVC conduit pipe …….dia .......mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws32MM, Dia 2.5 mm thick
180
-
-
Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.On wall / ceiling / Rafter / Girders
98
-
-
Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293.6Amps SP Switch
120
-
-
Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293.6A Three Way socket
120
-
-
Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293.16A One Way Switch
120
-
-
Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293.6/16A Universal Socket
120
-
-
Supplying and fixing hylum plastic sheet 4mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N.F. screws.
129419
-
-
Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board.6Amps SP Switch
50
-
-
Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board.6Amps 3 way 5 pin Socket
40
-
-
Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board.Electronic stepped regulator.
32
-
-
Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board.6 Amps lamp holder
50
-
-
Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switchplates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc.,complete.1-3Way
80
-
-
Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switchplates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc.,complete.6 Way
80
-
-
Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switchplates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc.,complete.8Way
80
-
-
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nutsetc., complete on the existing metal/PVC box.1 to 3 Module
80
-
-
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nutsetc., complete on the existing metal/PVC box.6 Module
80
-
-
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nutsetc., complete on the existing metal/PVC box.8 Module
80
-
-
Supply and fixing of UPVC Trunking 100x50 (MR)
129
-
-
Supply and fixing of Internal Coupler 100x50 (MR)
45
-
-
Supply and fixing of Joint cover 100x50 (MR)
45
-
-
Supply and fixing of End Cap 100x50 (MR)
50
-
-
Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete.Make:Crompton/Kruger.12" Sweep (300mm)
5
-
-
Fixing one exhaust fan after making a suitable notch in thewall and finishing with cement mortar and colouring to matchthe existing wall or brackets, with bolts and nuts and a 5 A,ceiling rose with sufficient length of 23 / 0.0076 inch PVCinsulated twin core wire of approved make with wire mesh
5
-
-
Supplying and wiring adopting loop system in existing PVC conduit / casing capping using 1100V grade , Copper conductor flexible multistrand FRLS PVC insulated , 2 X1.5 Sq.mm (Phase & Neutral) & 1 X 1.5 Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirmng to IS:694 : and latest ammendents) without control switch shall be fixtued on the existing plastic sheet/gang box, the other end of the wires shall be terminted with sufficient loose length in a wood / PVC round block. complete for each outlet.GROUP AShort point upto 3 Mtr from tapping point to outlet via switch
40
-
-
Supplying and wiring adopting loop system in existing PVC conduit / casing capping using 1100V grade , Copper conductor flexible multistrand FRLS PVC insulated , 2 X1.5 Sq.mm (Phase & Neutral) & 1 X 1.5 Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirmng to IS:694 : and latest ammendents) without control switch shall be fixtued on the existing plastic sheet/gang box, the other end of the wires shall be terminted with sufficient loose length in a wood / PVC round block. complete for each outlet.GROUP AMedium point above 3Mtr upto 6Mtr from tapping point to out let via switch
22
-
-
Labour Charges for 3KVA-1No, 5KVA-1No & 10KVA-2Nos UPS Shifting and Re-Installation & Removing old conduits and Existing Old Panel Dismelting.Wireman
5
-
-
Labour Charges for 3KVA-1No, 5KVA-1No & 10KVA-2Nos UPS Shifting and Re-Installation & Removing old conduits and Existing Old Panel Dismelting.Beldar/ coolie i-1012
5
-
-
Supplying and drawing UTP-CAT 6E LAN cable.
1950
-
-
Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable.2Pair
600
-
-
Supplying fixing of Network Switches.24 Port Gigabyte (Manageable) Make:Cisco/Aruba/Netgear,
1
-
-
Supplying fixing of Network Switches.48 port Gigabyte (Manageable) Make:Cisco/Aruba/Netgear,
3
-
-
Supplying of RJ45 connector jack
85
-
-
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.RJ45/ I.O.outlet Cat-6
85
-
-
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.TV/Telphone socket
22
-
-
Supplying & Fixing of Patch panel for LAN cabling.24 Port 10/100/1000 patch panel
1
-
-
Supplying & Fixing of Patch panel for LAN cabling.48 Port 10/100/1000 patch panel
3
-
-
Supplying & Fixing of switch mounting rack with power manager & Cable manager.9U with 450mm depth
2
-
-
Supplying & fixing of I/O socket with back box Double I/O
84
-
-
Supplying And Fixing "S" Hook made out of 14mm dia M.S.Rod.P-2,i-1.10
30
-
-
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
2
-
-
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.i-5.13
44
-
-
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thickincluding accessories, and providing masonry enclosure withcover plate having locking arrangement and watering pipe of2.7 metre long etc. with charcoal/ coke and salt as required.
1
-
-
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre belowground as strip earth electrode, including connection/ terminatingwith G.I. nut, bolt, spring, washer etc. as required. (Jointing shall bedone by overlapping and with 2 sets of G.I. nut bolt & spring washerspaced at 50mm)
22
-
-
Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. I-13.11
32
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements