Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
Indian Institute Of Science - IISC Tender
Electrical Works
Eprocure
Opening Date20 Feb 2025
Closing Date12 Mar 2025
Tender Amount₹ 12,49,23,516
Costs
EMD
₹ 12,49,235Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Dismantling Old Vrf Units, Supply, Installation, Testing And Commissioning Of New Vrv/vrf Systems Inclusive Of 05 Years Comprehensive Amc Of The Installed
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_IISC_850162_1Tender No
IISc/Tender-ELE-06/2024-25Tender Authority
Indian Institute Of Science ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
160HP
1
-
-
... More
152HP
1
-
-
... More
290HP
1
-
-
... More
172HP
2
-
-
... More
86HP
1
-
-
... More
140HP
1
-
-
... More
185HP
1
-
-
... More
CEILING MOUNTED HIGH STATIC DUCT TYPE - VRF:Supply, Installation, Testing and Commissioning of Ceiling Suspended type DUCTABLE INDOOR units with low noise, multi speed fan, multi row cooling coil, insulated extended drain pan, long life high quality filters, inbuilt drain pump, Canvas connection, corded remote control with thermostat, electronic expansion valve, fittings, supporting arrangement all complete as per Tender drawing and Specification.Units shall be suitable for input power supply of 1phase, 230volts, 50hz.Units shall be suitable for external static pressure of 200 Pascals.Noise level : 45 dBA @ 1.0M all around the unit 8.0 TR / 2966 CFM
247
-
-
... More
4.0 TR / 1342 CFM
6
-
-
... More
REFNET JOINTS : Necessary Ref joints, valves as per the schematic drawing.
253
-
-
... More
CENTRALIZED INTELLIGENT TOUCH REMOTE CONTROLLER : A mutifunctional compact centralized controller shall be provided with the system. It shall be able to control up to 64 groups of indoor units with the following functions:-
1) Starting / Stopping of Air conditioners as a zone or group or individual unit.
2) Temperature setting for each indoor unit or zone.
3) Switching between Temperature control modes, switching of fan speed and direction of airflow, enabling / disabling of individual remote controller operation.
4) Monitoring of operation status such as operation mode & Temperature setting of individual indoor units, maintenance information, trouble shooting information.
5) Display of air conditioner operation history.
6) Daily management automation through yearly schedule function with possibility of various schedules.
Controller shall have wide screen user friendly colour LCD display and can be wired by a non-polar 2 wire transmission cable to a distance of 1 km away from indoor unit.
4
-
-
... More
BMS CONNECTING KIT:Neccessary hard ware , software, integrator to integrate VRF system with BMS system of any make seamlessly.
1
-
-
... More
Low Side:REFRIGERANT PIPING : Supply, Installation, Testing & Commissioning of Refrigerant piping liquid and suction lines between the VRF aircooled outdoor units and indoor units. Piping shall be carried out with 16 G Hard drawn copper pipes with soldered / brazed socket fittings. Both suction and liquid lines shall be insulated with closed cell nitrile rubber insulation & exposed piping shall be covered with two layers of Fibre Glass cloth and coated with two layers of shield coating. 54.1 mm with 19 mm thick tubular insulation
600
-
-
... More
44.5 mm with 19 mm thick tubular insulation
400
-
-
... More
41.3 mm with 19 mm thick tubular insulation
500
-
-
... More
38.1 mm with 19 mm thick tubular insulation
200
-
-
... More
31.1 mm with 19 mm thick tubular insulation
600
-
-
... More
28.8 mm with 13 mm thick tubular insulation
600
-
-
... More
22.2 mm with 13 mm thick tubular insulation
600
-
-
... More
19.1 mm with 13 mm thick tubular insulation
450
-
-
... More
15.9 mm with 10 mm thick tubular insulation
500
-
-
... More
12.7 mm with 10 mm thick tubular insulation
600
-
-
... More
9.5 mm with 10 mm thick tubular insulation
600
-
-
... More
GI TRAY:2 mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts/nuts and washer or welding as required. 150 x 50 mm
100
-
-
... More
300 x 50 mm
10
-
-
... More
450 x 50 mm
10
-
-
... More
600 x 50 mm
150
-
-
... More
COMMUNICATION CABLE:Communication cabling of 3C x 1.5 Sqmm from Indoor to outdoor units, external wiring to be run in 1" dia GI conduit and inside wiring shall run in 1" dia PVC conduit
3000
-
-
... More
CONTROL CABLE:Contol wiring from all indoor units to CITRC, from out door units to CITRC, external wiring to be run in 1" dia GI conduit and inside wiring shall run in 1" dia PVC conduit
3000
-
-
... More
CORDED REMOTE CABLE: Remote cabling of 2C x 1.0Sqmm between each IDU & its wired remote to be suitably laid in 1' PVC conduit.
750
-
-
... More
POWER CABLE:Electrical Power cable between the indoor unit and power socket with 2 Core, 2.5 sqmm / as required, unshielded copper cable, with 1 no. plug top for each IDU.
300
-
-
... More
POWER CABLE:1.1 KV grade XLPE insulated, Cu conductor armoured and PVC sheathed cables.From ODU to nearest isolator / MCCB 4 C x 25 sqmm / as required
900
-
-
... More
4 C x 16 sqmm / as required
1400
-
-
... More
4 C x 10 sqmm / as required
450
-
-
... More
EARTH WIRE :Supply and Laying of following sizs of wires for earthing and to be run with the power cables along the cable tray/wall/ceiling as necessary. 25 X 3 GI Flat for Earthing
100
-
-
... More
40 X 6mm Flat for Earthing
100
-
-
... More
Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge
3000
-
-
... More
Supply, Installation Testing and Commissioning of Condensate Drain pump kit suitable for Ductable Units. Size shall be as per OEM recommendation.
15
-
-
... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32 mm nominal dia Pipe
900
-
-
... More
40 mm nominal dia Pipes
200
-
-
... More
G.S.S DUCTING as per SMACNA Standards:Supply, fabrication and installation of GI Ducting Along with flanges, supports & all fixing materials.24G. Ducting
1811
-
-
... More
22G. Ducting
1200
-
-
... More
VOLUME CONTROL OPPOSED BLADE DAMPER :Volume control damper shall be of low leakage type with the outer shell constructed of 1.6mm thick Anodized Aluminum frame and the blade/Leaf with 1.6mm thick Anodized Aluminum. And with necessary flanges for connection etc., as per specification.
28
-
-
... More
POWDER COATED GRILLES:Supply and fixing of powder coated extruded aluminium grill suitable for supply/return air including all fixing hardware etc.,. Complete. 6" extruded aluminium grill with 15 deg to 30 deg louvers
300
-
-
... More
COLLAR DAMPER:Supply & Installation of Collar damper constructed out of extruded aluminum alloy with multiple blade of oppose blade type. Shall be used for the Supply / Exhaust air diffuser & grilles as per the drawings & specifications
120
-
-
... More
ACOUSTIC LINING:Supply, Installation and Testing of Accoustic lining with Physically Crosslinked open cell polyolefin foam insulation for supply and Return air duct of density 30kg/m3 with Fire Retardant grades of thickness 15 mm. NRC of material should be atleast 0.35 tested as per ISO 354-2000 and calculated in accordance with ASTM C423-90A.
900
-
-
... More
THERMAL INSULATION :Supply and installation of Thermal insulation using 13mm nitrile rubber for return air ducts.
800
-
-
... More
Providing & Fixing of High Acoustical False Ceiling having NRC (Noise Reduction Coefficient) 0.90 (minimum) using Integral Densified edged Eco Friendly Fully Perforated Lightweight Calcium Silicate False Ceiling Tiles with Suitable to Modular Grid Size of 600x600mm with PPGI Slimline profile Balck/White reveal T 15 Grid system for Auditoriums, Community halls, Lecture Halls, Airports, Offices, Factories and All other High Acoustics required buildings. The Fully Perforated Lightweight Calcium Silicate False Ceiling tiles shall be made from Non Cementitious Hydrated Calcium Silicate Slurry/Mixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials. Doesn't contain any toxic ingrediants. The thickness of tiles should be 15mm at all around the edge resting portion with integral densified edge and 10mm thick at the quadrant. The tiles should have fiber glass fleece on rear side along with backing of 50mm thick rockwool slabs of density 48kg/m3 to achieve NRC 0.90 (Minimum)The tiles should have Humidity Resistance (RH) of 100%, Water Resistance, Non Combustible as per BS:476 Part-4, Fire Performance: Fire Propagation as per BS:476 Part-6, Class-1 for Surface Spread of Flame as per BS:476 Part 7, Class A or Class 1 as per ASTM E 84, Thermal Conductivity K= 0.048 to 0.052 w/m K as per ECBC code 2007, Size of the tile is 595x595mm, Density of tile should be 450 kg/m3 density all around on edge resting portion and 350kg/m3 density at the Quadrant, Light Reflectance 85%, Weight of the tile is 5-5.5 kg/m2 and Suitable for Green Building application with InOrganic Recycled content of 50% and meets the GRIHA norms under the categories: GRIHA V.2015 criterion:11&12, GRIHA V.3 criterion: 17&29 and SVAGRIHA criterion:12. The tiles Shall be laid on 15mm wide Polyester Powder Coated Galvanized Iron (PPGI) Slimline Profile Black/White reveal T-Sections Flanges colour white having rotary stitching double webbed on all T sections. The framework shall comprise of Main T runner with a web height of 38mm and 1200mm & 600mm Cross Tees with a web height of 38mm having sheet thickness of 0.4mm. The T sections should have Galvanizing of 120 g/m2 and need to be installed with Suspension system consisting of 12x50mm long dash fastners, Z cleat 25x37x25x1.6mm with pre cut hole on both 25mm flange to accomdate the 6mm dia bolt of the fasterner on one flange and 6mm fully threaded hanger rod uptom 1000mm length on the other. L-shape level adjuster of size 76x25x1.6mm to be fixed with T grid main runner. The entire grid rests on the perphery on a pre coated GI wall angle of size 15x20mm of sheet thickness 0.40mm of length 3000mm to be fixed on periphery wall/partition with the help of plastic rawl plugs at 450mm center to centerand 40mm long s.s screws. The work shall becarried out as per specifications, drawings and as per direction of Engineer in Charge.
320
-
-
... More
Repair to plaster of thickness 12 mm to 20 mm in patches of area 2.5 m2 and under, including cutting the patch in proper shape,raking out joints and preparing plastering the wall surface with white cement based polymer self curing mortar,including disposal of rubbish,all complete as per the direction of Engineer in charge.
1300
-
-
... More
Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacture,over the plastred wall surface to prepared the surface evenand smooth complete as per Specification andnas per direction of Engineer in charge
1300
-
-
... More
Wall painting with premium aceylic emulsino paint of interior grade, having VOC (Volatile Organic Compound) contentless than 50 Grams/litre of approved brand and manufacture,including applying additional coats wherever required to achieve even shade and colour .two coats as per Specification and as per direction of engineer in charge
1300
-
-
... More
Finishing walls with Acrylic smooth exterior paint of required shade :Old work (Two coat applied @1.67 1/10 m2)on existing cement paint surface including preparing the surface aftre thorughly cleaning the surface to remove all dirt,dust and foreign matter,cost of materials,labourcomplete as per specification and as per direction of Engineer in charge
1300
-
-
... More
Supply and installation of Tarpaulin canvas between the AC duct and AC evaporator unit including accessories.
253
-
-
... More
Dismantling of existing indoor,outdoor,ducts,copper piping and shifting of the same as per direction of engineer incharge
1
-
-
... More
Comprehensive Annual Maintenance contract per Annum
5
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%