Indian Institute Of Science Tender
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
Indian Institute Of Science - IISC Tender
Electrical and Electronics
Eprocure
Opening Date18 Jan 2021
Closing Date6 Feb 2021
Tender Amount₹ 8,74,00,000
Costs
EMD
₹ 13,11,000Document Cost
₹ 10,000Tender Fee
Refer Documents
Summary
Upgradation Of Substations In Iisc
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_IISC_610435_1Bid Award Id
ViewTender No
IISc/Tender 9/2020-21Tender Authority
Indian Institute Of Science ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply, erection, testing and commissioning of 500 KVA Copper wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, marshalling box with wiring, oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Bushing Type, stacked core with oil as per IS:1180 (Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335. The losses and impedance shall be as per IS: 1180 (level 3). (Make: Universal/ Voltamp/ Kirloskar/Toshiba)
2
-
-
Providing Civil Foundation for RMU with necessary concrete, size stones, angles / Channels and plastering works complete in all respects as per OEM Fondation Specification & Drawings.
3
-
-
SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 1000 KVA, 11KV/433V OUTDOOR COMPACT SUB-STATION WITH (2 x 500) KVA Dry Type Transformer WITH OCTC, ACB & MCCB WITH THE FOLLOWING ITEMS / COMPONENTS. HT panel RMU: 12Kv, 21kA, SF6 Insulated 5- Way Non extensible Compact Ring Main Unit comprising
(a) 2 Nos of Manual / Motorized (24V DC) operated Vacuum circuit breaker of 630A as EB supply loop in/ loop out with integral earth switch, with live cable indicators, with self-powered over current & earth fault relay, with shunt trip coil of 230v AC, with manual push buttons for closing/Tripping, with CTs for metering, with potential free contacts Breaker & Earth switch ON/OFF, with Local / remote switch with IEC 61850 Protocol compatible GE / Siemens relay. (b) 3 Nos of Manual / Motorized (24V DC) operated Vacuum circuit breaker of 630A as EB supply loop in/ loop out with integral earth switch, with live cable indicators, with self powered over current & earth fault relay, with shunt trip coil of 230v AC, with manual push buttons for closing/Tripping, with CTs for metering, with potential free contacts Breaker & Earth switch ON/OFF, with Local / remote switch with IEC 61850 Protocol compatible GE / Siemens relay. (c) Metering module comprising Potential transformer of 11kV/v3/110V/v3,50VA, CL 0.5, With R-Y-B Lamps, with space heater & thermostat, with space for RTU Unit, with multifunction meter, with Auxiliary transformer.
(d) With mimic diagram, with padlocking facility & with IP67 degree of protection for SF6 Tank, with 2x12V DC,12AH Battery& Charger.
Make : Schneider / Siemens/ Eaton (2x500) KVA Transformers : 11kV/433V, 2 x 500 KVA, 3 Phase, 50Hz, Dry type, DYN11, Air natural , Copper wound, With Off Circuit Tap switch, Tap range +5.0 to –10.0% in steps of 2.5% with PRV with contacts, with losses and impedance as per ECBC -2017. The Transformers shall be capable of operating in parallel. Dual LT Panel with Bus Coupler: LT Panel : 1) Incoming : 800 A, EDO ACB, 4 Poles, Manual Fixed, 50 KA, microprocessor based release for O/L, S/C, E/F protection with MP based LSIG release with following Accessories: (Make: Schneider / Siemens / L&T) - 2 Nos.
a) Motor Mechanism:230V AC b) Closing Coil:230V AC c) Shunt Trip Coil:230V AC d) 5NO+5NC Auxiliary Contacts e) 1C/O Trip Alarm Contact
2) 22.5mm Dia 230V AC LED type On, Off, Trip Indicators - 3 Nos (For each feeder) (Make :Teknic / Vaishno)
3) 22.5mm Dia 230V AC LED type RYB Indicators - 3 Nos (Make :Teknic / Vaishno) (For each feeder)
4) Resin cast L.T Single Phase 50Hz CTs 800/5A, Cl 0.5, 10 VA - 3 Nos (Make : Kappa/Kalpa) (For each feeder)
5) 3 Phase 4 Wire 415V AC Digital Multidata Meter & MDI, CTR:1600/5A, Class-0.5,96Sq.mm,Auxiliary Supply: 230V AC - 1 No (Make :Schneider) (For each feeder)
6) 1-8A ELR With Tape Insulated CBCT - 1 No (Make :ProkDVs / Minilec) (For each feeder)
7) 6A 4P C-Curve 10KA MCB - 1 No (For each feeder) 8) Bus coupler : 800 A, EDO ACB, 4 Poles, Manual Fixed, 50 KA, microprocessor based release for O/L, S/C, E/F protection with MP based LSIG release with following Accessories: (Make: Schneider / Siemens / L&T) - 1 No.
a) Motor Mechanism:230V AC b) Closing Coil:230V AC c) Shunt Trip Coil:230V AC d) 5NO+5NC Auxiliary Contacts e) 1C/O Trip Alarm Contact f) 22.5mm Dia 230V AC LED type On, Off, Trip Indicators - 3 Nos (Make :Teknic / Vaishno)
9) Out going : 6 x 630A, 4P MCCB with standard accessories
10) Cutout shall be provided to fix 96 Sq.mm smart meter (one for each Transformer LT side). Necessary connections from CT and PT are to be provided by the vendor. Meters will be provided by IISc.
7
-
-
SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 500 KVA, 11KV/433V OUTDOOR COMPACT SUB-STATION WITH (1 x 500) KVA Dry Type Transformer WITH OCTC, ACB & MCCB WITH THE FOLLOWING ITEMS /COMPONENTS. HT panel RMU: 12Kv, 21kA, SF6 Insulated 4- Way Non extensible Compact Ring Main Unit comprising (a) 2 Nos of Manual / Motorized (24V DC) operated Vacuum circuit breaker of 630A as EB supply loop in/ loop out with integral earth switch, with live cable indicators, with self-powered over current & earth fault relay, with shunt trip coil of 230v AC, with manual push buttons for closing/Tripping, with CTs for metering, with potential free contacts Breaker & Earth switch ON/OFF, with Local / remote switch with IEC 61850 Protocol compatible GE / Siemens relay. (b) 2 Nos of Manual / Motorized (24V DC) operated Vacuum circuit breaker of 630A as EB supply loop in/ loop out with integral earth switch, with live cable indicators, with self powered over current & earth fault relay, with shunt trip coil of 230v AC, with manual push buttons for closing/Tripping, with CTs for metering, with potential free contacts Breaker & Earth switch ON/OFF, with Local / remote switch with IEC 61850 Protocol compatible GE / Siemens relay. (c) Metering module comprising Potential transformer of 11kV/v3/110V/v3,50VA, CL 0.5, With R-Y-B Lamps, with space heater & thermostat, with space for RTU Unit, with multifunction meter, with Auxiliary transformer (d) With mimic diagram, with padlocking facility & with IP67 degree of protection for SF6 Tank, with 2x12V DC,12AH Battery& Charger.
(Make: Schneider /Siemens/ Eaton) (1x500) KVA Transformer : 11kV/433V, 1 x 500 KVA, 3 Phase, 50Hz, Dry type, DYN11, Air natural , Copper wound, With Off Circuit Tap switch, Tap range +5.0 to –10.0% in steps of 2.5% with PRV with contacts, with losses and impedance as per ECBC -2017.
(Make: Universal/Voltamp/Kirloskar/Toshiba) LT Panel : 1) Incoming : 800 A, EDO ACB, 4 Poles, Manual Fixed, 50 KA, microprocessor based release for O/L, S/C, E/F protection with MP based LSIG release with following Accessories: (Make: Schneider / Siemens / L&T) - 1 No.
a) Motor Mechanism:230V AC b) Closing Coil:230V AC c) Shunt Trip Coil:230V AC d) 5NO+5NC Auxiliary Contacts e) 1C/O Trip Alarm Contact
2) 22.5mm Dia 230V AC LED type On, Off, Trip Indicators - 3 Nos (Make :Teknic / Vaishno)
3) 22.5mm Dia 230V AC LED type RYB Indicators - 3 Nos (Make :Teknic / Vaishno)
4) Resin cast L.T Single Phase 50Hz CTs 800/5A, Cl 0.5, 10 VA - 3 Nos (Make : Kappa/Kalpa) 5) 3 Phase 4 Wire 415V AC Digital Multidata Meter & MDI, CTR:1600/5A, Class-0.5,96Sq.mm,Auxiliary Supply: 230V AC - 1 No (Make :Schneider)
6) 1-8A ELR With Tape Insulated CBCT - 1 No (Make :ProkDVs / Minilec)
7) 6A 4P C-Curve 10KA MCB - 1 No
8) Outgoing : 3 x 630A, 4P MCCB with standard accessories
9) Cutout shall be provided to fix 96 Sq.mm smart meter (one for each Transformer LT side). Necessary connections from CT and PT are to be provided by the vendor. Meters will be provided by IISc.
2
-
-
Civil Foundation for the above Compact Sub Station as per above with necessary concrete, size stones, angles / Channels and plastering works complete in all respects as per OEM Foundation Specification & Drawings.
9
-
-
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering GI pipe of 2.7-metre-long etc. with charcoal/ coke and salt as required as per the CPWD specification.
62
-
-
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
460
-
-
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
60
-
-
HT Cable: Supplying and laying of high tension 11KV cable, Dry Curing & Dry Cooling with true triple extrusion, simultaneously through a single common head, 3 core under ground XLPE (E) cable having stranded compact circular aluminium conductor, screened insulated, insulation screened with extruded semiconducting compound in combination with copper tape, core laid up extruded inner sheathed of GI flat strip armoured and overall PVC sheathed with specified IS 7098/11/85 with latest amendments.
a) 3C x 95sqmm
60
-
-
b) 3C x 150sqmm
300
-
-
Supplying and making 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations- OUTDOOR JOINTING KIT with latest amendments.
a) 3C x 95sqmm
10
-
-
b) 3C x 150sqmm
40
-
-
Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - STRAIGHT THROUGH JOINTING KIT.
3C x 150sqmm
20
-
-
LT cable: Supplying of 3.5 core 300 sqmm 1.1 KV LT UG cable having aluminum conductor PVC insulated, extruded inner sheathed, galvanized, steel strip confirming to IS-3975:1990 (No. of Strip indicated in GTP) & extruded PVC outer sheathed armoured cable with specified IS-1554 Part-1:1988 & confirming to GTP.
690
-
-
Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required.
690
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for 3.5 core 300 sqmm PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required
68
-
-
LT Panel: Supply, Installation, Testing and Commissioning of 3 Phase, 4 wire, 415 V, 50 Hz Outdoor panel, compartmentalised, panels with necessary Digital Ammeter and Voltmeter with selector switch, LED type RYB & ON-OFF Trip Indicators and having busbars of 1000 A capacity. The fabrication shall be made up of CRCA sheet with thickness of 3mm frame, 2.0mm front door with components, 1.6mm all other partition, Powder coated, with Electrolytic grade Aluminium busbars. Approval shall be obtained for the LT panel design before manufacturing.
Incomer :
1000A, 4 Pole, ACB, MP based OC, EF & SC protection, compatible Modbus communication - 1 No.
Outgoing: (MCCB)
400A - 6 Nos.
250A - 4 Nos.
100A - 4 Nos.
4
-
-
Painting of metal fence with 2 Coats of Red oxide & 2 coats of enamel paint of approved shade as required.
11
-
-
Safety Equipments: Supplying and fixing of the following Safety Equipments:
Shock treatment chart laminated (Kannada, English and Hindi) on 8mm Thick wooden board (24''x36'')
24
-
-
First aid kit with ABS plastic body, portable, transparent, wall mounting with contents
12
-
-
ISI marked 4.5 Kg capacity CO2 Fire Extinguisher with bracket etc.,
24
-
-
Fire buckets of 3 Nos set with Stand filled with sand and water with roof top cover
12
-
-
415V Danger board as per the regulations with local language (8''x8'')
48
-
-
Providing and fixing single line diagram of electrical network printed on A0 size photo paper framed with sandwiched fibre glass frame
12
-
-
Servicing of Existing LT panel: Servicing of LT Panel including complete testing of the LT Kiosk, breakers , bus bars, CTs, meters, contactors and all the protection relays. Test reports to be submitted on completion of testing. Reconditioning of the panels with complete cleaning inside /outside the panel and painting of the panel. Paint shade shall be matching the existing panel colour.
9
-
-
Yard Lightings: Supply and fixing of 70 Watts LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.
24
-
-
Supplying and Fixing 32 mm dia class A GI pipe bracket up to 2.0 meters long bent at suitable angle and fixing to street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires.
24
-
-
Supply, installation, testing & commissioning of Daylight Occupancy Sensor Switch:- Surface Mount with movement detector & daylight sensing with built-in switch. It will switch off the lights in a room or area when it is vacated or day light is sufficient enough and thus save up to 30% of electrical energy. The Occupancy switch Surface Mount can switch any load upto 6amps, Daylight override- Prevent Automatic switch-ON when sufficient daylight is available in order to create additional power savings. To enable this feature necessary settings are available on the device for adjusting required light level. Device mounting heights between 2.5 and 3.5 meter, for movement detection covering an area of 4 to 5 square meters (desk work) and 6 to 8 meters for larger movements like walking (at 25 deg Cel ambient). "Functions- Automatic controlof lights/electrical load switch ON/OFF automatically when any movement is detected, with adjustable time settings for Switch ON/OFF( 30 seconds to 30 minnutes ). Red LED indicator on detection of movement." Smart timer- The smart timer will extend the delay time by the set delay time if movement is detected shortly after switch off, assuming that the area is still in use, but very little movement is made. "Power Supply- Voltage 230 volts +/10%,. 50/60Hz AC Supply,..Maximum load 6 A. (1440 VA) any load. Maximum wire range 0.75 to 1.5mm2,..Mains distribution system TN-S with Neutral grounded,.."
12
-
-
Providing 40 mm dia agreegate for substation yard including the spreading etc as required.
24
-
-
Cat (B) - Buy Back Items
-
-
-
Buy-Back (ie minus) 250 KVA Transformer
7
-
-
Buy-Back (ie minus) 500 KVA Transformer
15
-
-
Buy-Back (ie minus) 750 KVA Transformer
2
-
-
Buy-Back (ie minus) RMU with LBS Panel
12
-
-
Buy-Back (ie minus) LT Panel
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements