Hindustan Aeronautics Limited Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Hindustan Aeronautics Limited - HAL Tender

Goods
Software and IT Solutions
Electronics Equipment
Electrical and Electronics
GEM
Opening Date9 Oct 2024
Closing Date29 Oct 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
. IP54 Level or equivalent NEMA standards of Ingress Protection.Front Transparent Toughened Glass Door with locks

-

-

-

... More
. Every door can open 120 degrees or more ,Rear Door Split Plan Door Integrated with Simple lock and Key.Cable Channel in Rear Side for Cable Management

-

-

-

... More
. Fixed Shelf or Rack Trays

-

-

-

... More
. Keyboard Tray Sliding / Rotary [1 Nos.]

-

-

-

... More
. Shelf for Display [1 Nos.]

-

-

-

... More
. Cable Manager 1U Horizontal [1 Nos.]

-

-

-

... More
. 150mm Width Vertical Cable Manager [2 Nos.]

-

-

-

... More
. Earthing Kit . 19” Mountable [Rail Kit]

-

-

-

... More
. 1U Blanking Panel [20 Nos.]

-

-

-

... More
. Hardware Packet [PKT of 20]

-

-

-

... More
. 100mm Base Plinth

-

-

-

... More
. Coupling Kit or Baying Kit [2 in each Rack]

-

-

-

... More
. Vertical Zero U Rack Mount PDU / Intelligent IP: 1 Phase, 32Amps,(min minimum 42U sockets with Min IEC C13 x 30 Sockets and Min IEC C19 x 6 Sockets ) with 32Amps MCB, 6 Sq.mm x 3 Core & 3 mtr Long Cable Length with 32Amps Industrial Plug Top [2 in each Rack]

-

-

-

... More
. Pure polyester Powered Coated Black RAL 9005 with 60 to 80 micron having 12 Tank Process Hot Phosphates or equivalent

-

-

-

... More
. Racks shall be manufactured by ISO 9001:2015, ISO 14001:2004 and ISO 45001: 2018 Certified company .

-

-

-

... More
RACK COOLING SYSTEM

-

-

-

... More
IN.RACK or IN ROW COOLING SYSTEM

-

-

-

... More
. Cooling Capacity 35KW to Cater 25KW of IT Load

-

-

-

... More
. Split Type Unit with Rack Side Mounted IDU(or equivalent inbuilt heater & humidifier ) and external ODU

-

-

-

... More
. Zero U Rack based type with Horizontal Uniform Cold Air Distribution(N+N Redundancy)

-

-

-

... More
. 35 KW side Mount unit

-

-

-

... More
OUTDOOR COOLING UNIT

-

-

-

... More
. Outdoor Fixing Frame : MS Frame (ODU is placed on the provided concrete platform on ground (apx 24 metes down from Server room) in which the ODU metal frame grouted to the foundation .)

-

-

-

... More
. Copper Piping and Draining Piping

-

-

-

... More
ACCESS CONTROL SYSTEM

-

-

-

... More
Access Control Lock: [4 Rack Solution] Biometric Access Control with Digital Lock with facility to record data

-

-

-

... More
REMOTE MONITORING UNIT

-

-

-

... More
. Hooter for Fire . Humidity Control

-

-

-

... More
. Auto Emergency Door or Door Switch Sensor

-

-

-

... More
. Water Leak Detection . Temperature Monitoring

-

-

-

... More
. Dry Contact Sensor

-

-

-

... More
. Notification & Event Alert.

-

-

-

... More
FIRE DETECTION & SUPPRESSION SYSTEM

-

-

-

... More
Rack mounted Fire Detection and Suppression system[4 rack solution]

-

-

-

... More
. Smoke Detector

-

-

-

... More
. NOVEC 1230 / FK-5-1-12 or equivalent Gas based Suppression

-

-

-

... More
. CE or equivalent Approved Clean agent cylinder, 2 kg per Rack capacity complete with all

-

-

-

... More
necessary fittings, connected with Direct Low Pressure Valve with UL Approved gas.

-

-

-

... More
. Pressure Switch

-

-

-

... More
. UL or equivalent Approved flexible polyethylene detection tube activating Mtr 16 . Extinguishing Agent Cylinder bracket

-

-

-

... More
. Battery Operated Sounder & Flasher

-

-

-

... More
. Panel with Smoke Detector

-

-

-

... More
RODENT REPELLENT SYSTEM

-

-

-

... More
Rodent Control or Rodent Repellent System[4 rack solution]

-

-

-

... More
ELECTRICAL WORKS

-

-

-

... More
Main Electrical Panel & Cabling

-

-

-

... More
DB panel mounted inside cabinet with all internal cabling integrated into the same. Adequate precaution and compliances will be taken care for sizing/ratings of cables and switchgear inside Rack

-

-

-

... More
UTILITY CABINET

-

-

-

... More
All Electrical and Fire Suppression system to be mounted.

-

-

-

... More
CCTV SYSTEM

-

-

-

... More
IP CCTV Camera:

-

-

-

... More
. Fixed Dome type Network Camera — 01 No

-

-

-

... More
. Resolution: 2MP . Frame Rate: 30 fps

-

-

-

... More
. Resolution: 1920x1080

-

-

-

... More
. Night Vision capable

-

-

-

... More
. IR Illuminator: built.in

-

-

-

... More
. Effective range: at least up to 10 Meters

-

-

-

... More
. Smart Motion Detection . Weather.proof (P66 / Indoor application )

-

-

-

... More
. 1 K 10-rated Protection.

-

-

-

... More
. 90 Days Storage

-

-

-

... More
BACKUP SYSTEM

-

-

-

... More
UPS & Batteries

-

-

-

... More
Rack Mount UPS & External Batteries: . 30KVA Rack Mount UPS and 30Mins Backup having External Sealed & Maintenance Free (SMF) Batteries(INCLUDED N+N TOPOLOGY) UPS to be mounted in the cabinet and batteries in battery bank enclosed

-

-

-

... More
WARRANTY :

-

-

-

... More
a) The Products manufactured shall provide warranty for 3 years from Date of Supply, Installation, Testing and Commissioning (SITC).

-

-

-

... More
b) For malfunction of any units/items in the rack, the support shall be provided within the next business day.

-

-

-

... More
c) Warranty claim shall be attended within 2 to 3 working days.

-

-

-

... More
MISCELLANEOUS:

-

-

-

... More
Scope of Work

-

-

-

... More
1. The Unit shall be shipped to HAL, Aerospace Division with all required accessories and fully Assembling the new server rack.

-

-

-

... More
2. DB Panel mounted with all internal cabling integrated in the panel

-

-

-

... More
3. Existing servers, switches etc. to be dismantled from the existing rack.

-

-

-

... More
4. Servers, switches etc. to be fixed in to the new rack.

-

-

-

... More
5. Cabling, & dressing of rack.

-

-

-

... More
6. Re.work for the power connectivity.

-

-

-

... More
7. Fixing of LIU & LIU termination for switches.

-

-

-

... More
8. Testing of network, after completion of connectivity.

-

-

-

... More
9. Final confirmation to be given once all the servers, switches etc. are powered on to go live.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.