Health And Family Welfare Department Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Health And Family Welfare Department Tender

Works
Civil And Construction
Building Construction
Opening Date9 Dec 2024
Closing Date23 Dec 2024
Tender Amount₹ 1,77,79,438.16 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
I-4.1 P-5 V-2 - Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

85.56

132

11307.6096

... More
I-1.9 P-7 V-1 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

34.71

297

10340.8032

... More
I-1.8 I-7 V-1 - Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

26.26

530

13940.9088

... More
I-2.1.3 P-15 V-1 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

14.77

6707

99072.4336

... More
I-2.2.1 P-15 V-1 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Footings ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

4.56

7604

34677.7056

... More
I-2.2.1 P-15 V-1 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PEDESTALS ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

1.01

7745

7823.0358

... More
I-2.5.2 P-17 V-1 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Columns ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

3.52

13029

45862.3264

... More
I-2.5.2 P-17 V-1 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Plinth Beam GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

5.77

11496

66333.3048

... More
I-2.5.2 P-17 V-1 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC Beams, Lintels GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

8.16

12262

100063.3056

... More
I-2.5.2 P-17 V-1 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC Slab GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

10.97

11496

126113.7528

... More
I-2.1.4 P-15 V-1 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

2.03

11140

22615.9458

... More
I-8.16A P-55 V-2 - Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications. GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

4.5

1386

6239.52

... More
I-2.11A P-84 V-2 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a) BUILDING GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

3.66

100191

366702.1344

... More
I-5.4 P-9 V-2 - Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

2.44

7155

17459.8592

... More
I-6.32 P-17 V-2 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

203.32

1467

298311.104

... More
I-6.34 P-17 V-2 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

15.17

1236

18757.4016

... More
I-12.13.1 P-100 V-2 - Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

0.4

110672

44269.12

... More
I-12.51 P-105 V-2 - Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

5

1137

5689.6

... More
I-12.60 P-107 V-2 - Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

15

1178

17673.6

... More
I-12.61 P-107 V-2 - Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

15

1108

16632

... More
I-12.62 P-107 V-2 - Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

15

265

3981.6

... More
I-12.63 P-107 V-2 - Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

15

145

2184

... More
I-12.64 P-107 V-2 - Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

15

61

924

... More
I-12.75.1 P-108 V-2 - Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

18

308

5544

... More
I-10.6.3 P-69 V-2 - Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

18

67

1209.6

... More
I-12.57.6 P-106 V-2 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial GROUNDFLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

12.92

3720

48070.6688

... More
I-12.90 P-112 V-2 - Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

11.25

7542

84848.4

... More
I-12.85 P-110 V-2 - Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

17.46

6405

111836.1888

... More
I-11.34A P-110 V-2 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

247.59

188

46586.5344

... More
I-12.93.2 P-111 V-2 - Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 125mm GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

5.2

855

4449.536

... More
I-12.94.2 P-112 V-2 - Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 35 mm thickness GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

2.1

4525

9504.432

... More
I-12.59 P-107 V-2 - Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

12

1247

14972.16

... More
I-11.25.2 P-109 V-2 - Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

4490.72

152

684026.4704

... More
I-11.35.1.1 P-86 V-2 - Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications. GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

84

506

42524.16

... More
I-11.37.1 P-88 V-2 - Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

8.4

1106

9295.104

... More
I-8.10 P-41 V-2 - Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Inside) GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

74.7

295

22066.38

... More
I-8.5.2 P-41 V-2 - Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

117.41

488

57366.526

... More
I-8.51 P-50 V-2 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

192.11

112

21516.32

... More
I-8.8 P-42 V-2 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.( Outside) GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

216.69

519

112548.786

... More
I-15.36 P-118 S.R 2018-19 - KSRB 15.8.3 Providing and fixing plaster mesh 150mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per Sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment ) GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

346.2

42

14734.272

... More
I-8.79 P-54 V-2 - Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

122.3

58

7122.752

... More
I-9.21.2 P-62 V-2 - Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).).Size of Tile 600x600 mm GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

72.5

1386

100525.6

... More
I-8.2.1 P-41 V-2 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

158.52

330

52375.008

... More
I-9.11 P-60 V-2 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

1.82

995

1812.1376

... More
I-9.39 P-65 V-2 - Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

158.53

1622

257275.1664

... More
I-9.14 P-61 V-2 - Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

158.53

395

62676.4208

... More
I-8.39 P-48 V-2 - Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

192.13

142

27328.5712

... More
I-8.31 P-45 V-2 - Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

216.7

199

43201.312

... More
I-8.34.3 P-47 V-2 - Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

11.79

56

660.24

... More
I-8.34.1 P-47 V-2 - Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

40.61

59

2410.6096

... More
I-8.40 P-48 V-2 - Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

76.75

128

9885.4

... More
I-10.2 S.R 2018-19 - KSRB 10-3 :Providing and laying integral cement based waterproofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc , consisting of following application. (a) Applying and grouting a slurry coat of neat cement using 2.75 kglsqm of cement admixed with proprietary water proofing compound conforming to 18:2645 over the RCC slab after cleaning the surface before treatment. (b) Laying cement concrete using broken brick bats 25mm to 1OOmm size with 50% of cement mortar 1:5 admixed with proprietary water proofing compound conforming 18:2645 over 20mm thick layer of cement mortar 1:5 admixed with proprietary water proofing compound to required slope and treating similarly the adjoining walls upto 300mm height including rounding off junctions of walls and slabs. (c) After two days of proper curing, applying a second coat of cement lurry admixed with proprietary water proofing compound (d) Finishing the surface with 20mm thick joint less cement mortar of mix 1:4 admixed with proprietary water proofing compound and finally finishing the surface with trowel and neat cement slurry and making of 300x300mm square. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test including cost of materials, labour complete as per specifications.I.No 10.2 rs 1009 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

78.32

1130

88507.8656

... More
I-10.1.7 P-135 V-5 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 110mm dia., 6 kg/sqcm & class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

24

460

11047.68

... More
PWD SR 2023-24 VOL-02, ITEM NO- 20.50, P- 203 - Removing white wash or colour wash by steel brushing and / or scraping, sand papering and preparing wall surface smooth including repairs to scraches including cost of labour, material complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

17709.39

14

257848.7184

... More
PWD SR 2023-24 VOL-02, ITEM NO- 8.54.2, P- 50 - Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

10879.86

123

1340398.752

... More
PWD SR 2023-24 VOL-02, ITEM NO- 8.75.1, P- 53 - Finishing walls with Premium Acrylic Smooth exterior paint of required shade : Old work (Two coats applied @ 1.43 ltr/ 10 m²) over existing cement paint surface including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

6187.53

124

769233.7296

... More
PWD SR 2023-24 VOL-02, ITEM NO- 19.55, P- 193 - Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground to the appropriate disposal area as per direction of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

702

41

29090.88

... More
PWD SR 2023-24 VOL-02, ITEM NO- 8.5.2, PAGE NO- 42 - Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

262.5

390

102606

... More
PWD SR 2023-24 VOL-02, ITEM NO- 10.14, PAGE NO- 71 - Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

277.5

1238

343744.8

... More
PWD SR 2023-24 VOL-02, ITEM NO- 20.109, P- 207 - Repairs to existing aluminium partition including glass,board, lock, handle, beading etc cost of all material,labour, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

62.5

2543

158970

... More
PWD SR 2023-24 VOL-02, ITEM NO- 20.88, P- 206 - Repairs to plaster in patches of 2.5 m2 and less in walls, ceilings 10 to 20mm thick in cement mortar 1:3 including cutting the patches in proper shape and replastering the surface of the wall including disposal of rubbish with a lead of 50m including curing cost of materials, labour, complete as per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

202.05

446

90292.104

... More
PWD SR 2023-24 VOL-02, ITEM NO- 8.64, PAGE NO- 51 - Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One coats on old work as per specifications and as per directions of Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

1746

85

148619.52

... More
PWD SR 2023-24 VOL-02, ITEM NO- 9.12.2, P- 60 - Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. - Size of Tile 600x600 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

684.38

1282

877648.912

... More
PWD SR 2023-24 VOL-02, ITEM NO- 19.22.1, P- 189 - Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-charge. - For thickness of tiles 10 mm to 25 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

451

53

24245.76

... More
PWD SR 2023-24 VOL-02, ITEM NO- 19.2.1, P- 187 - Demolishing cement concrete manually/ by mechanical means including ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

90.3

1862

168189.168

... More
PWD SR 2023-24 VOL-02, ITEM NO- 15.1, PAGE NO- 149 - Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

451

915

412683.04

... More
PWD SR 2023-24 VOL-02, ITEM NO- 7.18, PAGE NO- 23 - Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

255

2259

576055.2

... More
PWD SR 2023-24 VOL-02, ITEM NO- 9.9, PAGE NO- 60 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

351

1205

422997.12

... More
PWD SR 2023-24 VOL-02, ITEM NO- 19.12.2, P- 164 - Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking to the appropriate disposal area as per direction of Engineerin- charge. - Of area beyond 3 m² ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

285.12

293

83665.6128

... More
PWD SR 2023-24 VOL-02, ITEM NO- 12.83.1, P- 108 - Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance plus or minus 1mm), with wall thickness 2.0 mm (plus or minus 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (plus or minus 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer- in-charge - 48x40 mm PVC Extruded section ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

150

221

33264

... More
PWD SR 2023-24 VOL-02, ITEM NO- 12.84, P- 108 - Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

169.5

5625

953566.32

... More
PWD SR 2023-24 VOL-02, ITEM NO- 12.57.2, P - 105 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick one side teak and one side commercial ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

168.48

3912

659120.7168

... More
PWD SR 2023-24 VOL-02, ITEM NO- 12.59, P- 105 - Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

10

133

1336.8

... More
PWD SR 2023-24 VOL-02, ITEM NO- 20.113, P- 208 - Repair to existing ply wood ward-robes with 19mm plywood, beading,laminate and all necessary including cost of materials labour, lead,lift complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

80.1

882

70693.056

... More
PWD SR 2023-24 VOL-03, ITEM NO-15.5 B,PAGE NO- 135 - Sealing of cracks/porous concrete by injection process through nipples/Grouting complete as per Technical Specification. Cement Mortar (1:1) Grouting ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

170

304

51788.8

... More
PWD SR 2023-24 VOL-02, ITEM NO- 9.36, PAGE NO- 64 - Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

60

1848

110880

... More
PWD SR 2023-24 VOL-02, ITEM NO- 7.1.1 , P- 21 - Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge. 0.63 mm thick with zinc coating not less than 275 g/ m². ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

880

984

866342.4

... More
PWD SR 2023-24 VOL-02, ITEM NO- 20.104 , P-207 - Repairing and fixing shutters (panelled or glazed) to doors, windows, ventilators and cupboards. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

294.68

1092

321790.56

... More
PWD SR 2023-24 VOL-02, ITEM NO- 8.9 , P- 42 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

24.36

431

10504.032

... More
PWD SR 2023-24 VOL-03, ITEM NO-15.4, PAGE NO- 135 - Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical pecifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

75

228

17136

... More
PWD SR 2023-2024 VOL-1 ITEM NO : 1.12 - Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

635.8

106

67649.12

... More
PWD SR 2023-2024 VOL-3 ITEM NO : 16.8 B - Surface Drains in Soil. Construction of unlined surface drains of average cross- sectional area 0.40 m2 in soil to specified lines, grades, levels and dimensions. Excavated material to be used in embankment with a lift upto 3m and lead of 50 m (average lead 25 m) as per Technical Specification Clause 307. Mechanical Means ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

2312

28

64736

... More
PWD SR 2023-2024 VOL-3 ITEM NO :4.1(V) - Granular Sub-Base Plant Mix Method. Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401. For Grading -V Material ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

78.03

2785

217347.8832

... More
PWD SR 2023-2024 VOL-3 ITEM NO :4.17 P: 26 - Wet Mix Macadam (Plant Mix Method). Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

135.34

2866

387895.2672

... More
PWD SR 2023-2024 VOL-1 ITEM NO :1.7 P :07 - Construction of Embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded with desired compaction. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

381.48

133

50843.6544

... More
PWD SR 2023-2024 VOL-3 ITEM NO : 3.6 P: 17 - Construction of Subgrade and earthen Shoulders. Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

64.5

552

35614.32

... More
PWD SR 2023-2024 VOL-3 ITEM NO : 5.1(i) P: 31 - Prime Coat over WMM/WBM Providing and applying primer coat with SS1 grade Bitumen Emulsion on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70 kg/m 2 using mechanical means. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

462.4

45

21233.408

... More
PWD SR 2023-2024 VOL-3 ITEM NO : 5.4(ii) P 31 - Tack coat on Granular surface treated with primer Providing and applying tack coat with RS1 Bituminous Emulsion using emulsion pressure distributor at the rate of 0.25 kg/m 2 on Granular Surface. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

462.4

15

7250.432

... More
PWD SR 2023-2024 VOL-3 ITEM NO : 5.3(i) P 31 - Tack coat on Bituminous surface Providing and applying tack coat with RS1 Bituminous Emulsion using emulsion pressure distributor at the rate of 0.20 kg/m 2 on the prepared bituminous surface cleaned with mechanical broom ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

2167.5

13

29131.2

... More
PWD SR 2023-2024 VOL-3 ITEM NO : 10.5 P 31 - Filling Pot-holes and Patch Repairs with Bituminous concrete, 40mm (using Vg-30 grade Bitumen) Removal of all failed material, trimming of completed excavation to provide firm vertical faces, cleaning of surface, painting of tack coat on the sides and base of excavation as per clause 503, back filling the pot holes with hot bituminous material as per clause 504 using HMP 40/60 TPH Capacity compacting, trimming and finishing the surface to form a smooth continuous surface, all as per clause 3004.2 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

52.02

477

24819.7824

... More
PWD SR 2023-2024 VOL-3 ITEM NO : 5.8(A) P 31 - Bituminous Macadam Grading - II for traffic less than 20 MSA: Providing and laying Bituminous Macadam with 120 TPH capacity hot mix plant batch type using crushed aggregates of specified grading premixed with bituminous binder VG-30 @ 3.4% by weight of mix, transported to site, laid over a previously prepared surface with mechanical paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

110.98

8663

961441.936

... More
PWD SR 2023-2024 VOL-3 ITEM NO : 5.31 P 43 - Semi Dense Bituminous Concrete Providing and laying Semi Dense Bituminous Concrete with 40/60 TPH capacity hot mix plant batch type using crushed aggregates of specified grading premixed with bituminous binder VG-30 @ 5% by weight of mix and filler, transported to site, laid over a previously prepared surface with mechanical paver finisher to the required grade, level and alignment and rolled as per MoRTH V revision.led as per MoRTH V revision. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

54.19

11370

616153.3056

... More
PWD SR 2023-2024 VOL-3 ITEM NO : 8.5(iv) P 64 - Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC:67:2022 made of Class B Type IV retro reflective sheeting fixed over 2 mm thick aluminium sheeting vide clause 803.1, 3mm/4mm thick Aluminium composite material sheet depending on the size of the sign fixed over the back support frame of min 25 x 25 x 3mm angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing.The sign shall be maintained as per section 12 of IRC:67:2022 ( iv )60 cm equilateral triangle ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

6

4005

24030.72

... More
PWD SR 2023-2024 VOL-3 ITEM NO : 8.7 P 64 - Direction and Place Identification Signs upto 0.9 m2 Size Board Providing and erecting direction and place identification retro- reflectorised sign as per IRC:67:2022 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick or Aluminium composite material sheet with overall thickness of 4mm with area not exceeding 0.9 m 2 fixed over back support frame of min 35 x 35 x 3mm angle mounted on a mild steel circular pipe 65 NB, firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge

1.8

10091

18164.16



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.