Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Health And Family Welfare Department Tender

Works
Civil And Construction
Building Construction
Opening Date7 Mar 2025
Closing Date20 Mar 2025
Tender Amount₹ 87,38,246.85 
Notes
Download

Costs

Summary

Construction Of District Integrated Public Health Laboratory In The Premises Of District Hospital At Chikkaballapura In Chikkaballapura District.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
1.3.1 V6 - Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe 19/20dia 2mm thick confirming to IS 2509 with suitable size bends metal/PVC junction boxes adhesive paste etc. by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

120

70

8404.8

... More
1.3.2 V6 - Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe 25dia 2mm thick confirming to IS 2509 with suitable size bends metal/PVC junction boxes adhesive paste etc. by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

150

81

12205.5

... More
1.3.3 V6 - Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe 32dia 2.5 mm thick confirming to IS 2509 with suitable size bends metal/PVC junction boxes adhesive paste etc. by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

20

101

2039.4

... More
1.12 V6 - Supplyin and Fixing Metal Fan Box with Round Hook. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

15

164

2472

... More
2.2.1 V6 - Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

15

277

4156.05

... More
2.2.2 V6 - Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

30

390

11711.1

... More
2.2.3 V6 - Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

20

571

11433

... More
2.3.2 V6 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:confirming to latest amendments. 1.5 Sqmm ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

200

26

5356

... More
2.3.3 V6 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:confirming to latest amendments. 2.5Sqmm ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

675

43

29200.5

... More
2.3.4 V6 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:confirming to latest amendments. 4Sqmm ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

530

64

34391.7

... More
2.3.5 V6 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:confirming to latest amendments. 6 Sqmm ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

50

94

4738

... More
2.3.6 V6 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:confirming to latest amendments. 10 Sqmm ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

60

172

10320.6

... More
3.4.1 V6 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 12WAY ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

5

142

710.7

... More
3.4.2 V6 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3WAY ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

2

163

327.54

... More
3.4.3 V6 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4WAY ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

4

182

729.24

... More
3.4.4 V6 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6WAY ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

2

226

453.2

... More
3.4.5 V6 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8WAY ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

21

268

5645.43

... More
3.5.1 V6 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws bolts nuts etc. complete on the existing metal/PVC box. 1 to 2 Module ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

5

141

705.55

... More
3.5.2 V6 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws bolts nuts etc. complete on the existing metal/PVC box. 3 module ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

2

165

331.66

... More
3.5.3 V6 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws bolts nuts etc. complete on the existing metal/PVC box. 4 Module ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

4

180

721

... More
3.5.4 V6 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws bolts nuts etc. complete on the existing metal/PVC box. 6 Module ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

2

241

482.04

... More
3.5.5 V6 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws bolts nuts etc. complete on the existing metal/PVC box. 8 Module ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

21

292

6142.92

... More
3.6.1 V6 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

115

105

12081.9

... More
3.6.3 V6 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

50

176

8806.5

... More
3.6.4 V6 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

15

367

5515.65

... More
3.6.10 V6 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

16

243

3889.28

... More
3.6.11 V6 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone Socket ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

16

160

2570.88

... More
5.18.9 V6 - Supplying and fixing of 5063Amps TPN miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve indicator ON/OFF energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

1

3180

3180.64

... More
5.19.12 V6 - Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clampsi bolts nuts etc. with provision for fixing suitable type capacity MCBs single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure double door 6 Way TP & N ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

1

5088

5088.2

... More
5.18.1 V6 - Supplying and fixing of 632Amps SP miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve indicator ON/OFF energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

28

427

11968.6

... More
5.18.9 V6 - Supplying and fixing of 5063Amps TPN miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve indicator ON/OFF energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

1

3180

3180.64

... More
5.20.1 V6 - Supplying fixing and wiring 16A25A 2 pole Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel boar ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

4

4405

17621.24

... More
11.5.2 V6 - Supply of round recess/surface mounted rolling type LED Down light with 12W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring with Life of 25000 burning hours & 70% lumen maintenance with CRI more than 80. Power Input: 220240V @ 50/60Hz & Power factor more than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical conditionLED square or round down light 1012W ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

14

911

12761.7

... More
11.3.2 V6 - Supplying of 4feet PVC Batten with integrated LED tube 20W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI more than 80. Power Input: 220240V @ 50/60Hz & Power factor more than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

4

710

2842.8

... More
11.11.3 V6 - Supplying & fixing of retrofit type LED bulb 7 W 6500K with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K CRImore than 70%. efficacy more than80 lumen per watt lifemore than 25000 burning hours and Compliance to IS 10322/IEC 60598 LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system with PF more than 0.95 power loss should lesser than 5% of lamp wattage. short circuit & open circuit protection to be integrated in the circuit THD less than 20% Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

2

153

306.94

... More
11.11.5 V6 - Supplying & fixing of retrofit type LED bulb 12W 6500K with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K CRImore than 70%. efficacy more than80 lumen per watt lifemore than 25000 burning hours and Compliance to IS 10322/IEC 60598 LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system with PF more than 0.95 power loss should lesser than 5% of lamp wattage. short circuit & open circuit protection to be integrated in the circuit THD less than 20% Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

2

277

554.14

... More
11.6.3 V6 - Supplying of recess mounting non integral type LED modular down light 2x2 36 W luminaire comprising of pressure decast/extruded aluminium housing with spring loaded fase ceiling clamps Power LEDs with CCT 6500 degree K CRImore than 70%. efficacy more than100 lumen per watt 120degree beam spread lifemore than 25000 burning hours and Compliance to IS 10322/IEC 60598 LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly. with PF more than 0.95 power loss should lesser than 5% of lamp wattage. short circuit & open circuit protection to be integrated in the circuit THD less than 20% Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

18

4689

84412.62

... More
11.8.2 V6 - Supply of 40w LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70% maximum light intensity should be between 60 degrees to 70 degrees. CCT more than 5500K IP 66 optical and electrical compartment & impact resistance of complete luminaire more than IK08. Power Factor more than0.9 with mains Surge Protection Min 5KV along with Over voltage/ Overload short circuit/ misswiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598 LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 40W System Power consumption. LED Efficiencymore than130lm/w nominal CRI more than75. Luminaire manufacturer should have inhouse facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

2

4144

8289.44

... More
6.1 V6 - Supplying exhaust fan of 1440 RPM of 300mm (12) size with bracket blades complete for light duty suitable to operate on 230V 50Hz AC Supply. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

1

1536

1536.76

... More
6.2.2 V6 - Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz AC Supply complete. 15 Sweep (450 mm) ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

4

4579

18317.52

... More
6.3.1 V6 - Supplying capacitor type ceiling fan complete with down rod blades shackle canopies etc. for operation on 230 volts 50 cycles. Single phase AC supply conforming to ISS3741979 and with double ball bearing system. 48 Sweep (1200mm) Regular model ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

14

3073

43029.28

... More
12.46 V6 - Supplying & Fixing of 70150 Watts lamp holder 2 Pin ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

86

64

5580.54

... More
13.7.1 V6 - Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

38

125

4775.08

... More
13.11 V6 - Fixing a ceiling / wall mounting fan of all capacities and all types with necessary clamps and S hook made out of 15mm dia MS rod with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality mounted on a suitable size wooden board and wired. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

14

324

4542.3

... More
13.13 V6 - Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets with bolts and nuts and a 5 amps ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

5

728

3641.05

... More
13.4.1 V6 - Supplying and fixing telescopic M.S. single bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe with 2 inch dia 1.5m long M. S. bracket and are welded with suitable angle using 6mm thick M. S. sheet grip bolts & nuts as required suitable for 9 to 12 Mtrs. M. S. tubular pole with necessary two coats of painting with all other accessories. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

2

1504

3009.66

... More
13.5 V6 - Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps bolts nuts and wiring using suitable capacity wires. ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

2

166

333.72

... More
5.17.1 V6 - SupplyingandfixingregularMCCBdistributionPanelconfirmingtoIS/IEC61439 and IK09testedasperIS/IEC62262withminimumIP43protectionprovidedwithPolyurethane(PUR)gasketwithsuitableearthingsystemonwall/woodboard/flushmountingusingrequiredclAboltsnutsetc.withprovisionforfixingofsuitabletypecapacityMCCBsasanincomerfor3phaseDoubledoorwithnecessarybusbarcompletelywiredtouseon440V3phase4wirepowdercoatedpaintingetc.completewithaprovisionforfixingofsingle/threephasesuitablecapacityMCBsasoutgoingsconfirmingtoIS/IEC 60898 4 way ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

1

10638

10638.87

... More
5.15.9 V6 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws bolts nuts necessary phase separators handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS13947. (Icu=100% lcs). In 4P MCCB all Poles should have protection for ShortCicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and NonPriority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multipole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 100Amps 25kA ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

1

8741

8741.61

... More
5.18.1 V6 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve indicator ON/OFF energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 632Amps SP ---- Complete with all lead and lift loading and unloading charges etc., work should be carried out as per the Specification and direction of Engineer in Charge of the work

4

427

1709.8



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.