Gulbarga Electricity Supply Company Limited Tender

... More
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Gulbarga Electricity Supply Company Limited - GESCOM Tender

Works
Civil And Construction
Building Construction
Opening Date13 Feb 2025
Closing Date15 Mar 2025
Tender Amount₹ 18,60,11,802.63 
Notes
Download

Costs

Summary

A) Construction Of Circle Office Building At Koppal.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m (Common SR 2023-24 Item No. 1.14.1, Page No. 8 Vol-01)

3897.44

107

417415.824

... More
code05 - Earth work excavation for Foundation by mechanical means for all works & depth upto 3m as per drawing & technical specifications,including setting out, shoring,strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m & lift upto 1.5 m including cost of labour,tools,usage of machinery & other appurtenaces required to complete the work.Depth exceeding 1.5 m, but not exceeding 3m for ordinary/soft rock without blasting (Common SR 2023-24 Item No.1.15.2,Pg No.9 Vol-01)

3079.6

446

1374271.5

... More
code06 - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools,usage of machinery & other appurtenaces required to complete the work. Depth exceeding 3.0 m, but not exceeding 4.5 m for ordinary/soft rock without blasting (SR 2023-24 Item No.1.15.3,Pg No.9 Vol-01

739.97

486

359736.4155

... More
code07 - 1.23 Providing & Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering,including cost of all materials and labour with all lead & lift complete as per specifications.( SR Vol-1 Item no-1.23 Pg 11 )

123.31

2816

347253.291

... More
code08 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse a+gregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates (Common SR 2023-24 Item No. 2.1.2, Pg No.15 Vol-01)

399.14

5947

2373765.408

... More
code09 - Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (SR 2023-24 Item No. 5.4, Page No. 9 Vol-02)

32.8

6708

220037.16

... More
code10 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (1 cement : 6 coarse sand) (Common SR 2023-24 Item 1.9 Pg No. 7 Vol-01)

1715.88

279

479245.284

... More
code11 - Providing & laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates & fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts,cost of all materials,quality confirming to the requirements of relevant IS codes,labour,Usage charges of machinery,curing & all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Common SR 2023-24 Item No. 2.2.1, Pg No. 15 Vol-01) For Foundation Concrete Such as I) Footings,Retaing wall raft & ramp, II) Pedestals III) Coloumns upto plinth beam, IV) Retaining wall,Plinth beam,Portico plinth beams,Sump,Septic tank & Storm water drain water tank V) Drain

1398.43

6601

9231525.8805

... More
code12 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Common SR 2023-24 Item No. 2.5.1, Page No. 16 Vol-01)For Cellar Floor Concrete such as I)Columns From Plinth Beam to Cellar Roof Beam II) Cellar Floor Cill III)Staircase From Cellar to GF IV) Cellar Floor-Lintel V) CF Roof Slab,Sump tank,Septic tank & Storm water drain water tank

644.71

6961

4488148.665

... More
code13 - For Ground Floor Concrete such as I) Coloumns from GF slab to GF roof beam II)Ground Floor Cill III)Staircase 1 &2 From GF to FF IV) GF Chejja V)Ground Floor Lintel & Roof beam VI) GF Roof slab

388.86

6961

2707048.89

... More
code14 - For First Floor Concrete such as I) Coloumns from First Floor Slab to First Floor Roof Beam II)First Floor Cill III)Staircase 1 &2 From FF to SF IV) FF Chejja V)First Floor Lintel & Roof beam VI) FF Roof slab

412.97

7031

2903641.6264

... More
code15 - For Second Floor Concrete such as I) Coloumns from Second Floor Slab to Second Floor Roof Beam II) Second Floor Cill III)Staircase 1 &2 From SF to TF IV) SF Chejja V)Second Floor Lintel & Roof beam VI) SF Roof slab

429.08

7100

3046781.2284

... More
code16 - For Terrace Floor Concrete such as I) Coloumns from Terrace Floor Slab to Terrace Floor Roof Beam II) Terrace Floor Cill III) TF Chejja IV) Terrace Floor Lintel & Roof beam VI) Terrace Floor Roof slab

79.18

7170

567748.313

... More
code17 - For Foundation Consider 8% rate on concrete rate for Shuttering Qty of Footings, Retaing wall raft & ramp (

663.58

528

350443.2338

... More
code18 - For Foundation Consider 70% rate on concrete rate for Shuttering Qty of Pedestal

49.64

4620

229383.958

... More
code19 - For Foundation Consider 70% rate on concrete rate for Shuttering Qty of Coloumns Upto Plinth beam

29.35

4620

135624.8825

... More
code20 - For Foundation Consider 50% rate on concrete rate for Shuttering Qty of Retainign wall,plinth beam,Portico plinth beams,sump,Septic tank,Storm water drain water tank

446.56

3300

1473951.6608

... More
code21 - For Foundation Consider 35% rate on concrete rate for Shuttering Qty of Drain,

33.35

2310

77054.1745

... More
code22 - Centering and shuttering for Drain septic soak pit sump slab

17.72

3300

58488.0496

... More
code23 - Centering and shuttering for staircase 50%

2.97

3300

9803.0196

... More
code24 - For CF Consider 70% rate on concrete rate for Shuttering Qty of Columns From Plinth Beam to Cellar RB

58.2

4873

283611.51

... More
code25 - For Cellar Floor Consider 50% rate on concrete rate for Shuttering Qty of Cellar Floor Cill

0.9

3480

3132.675

... More
code26 - For Cellar Floor Consider 50% rate on concrete rate for Shuttering Qty of Staircase From Cellar to GF

4.34

3480

15106.455

... More
code27 - For Cellar Floor Consider 50% rate on concrete rate for Shuttering Qty of CF Lintel to CF Roof beam

121.65

4176

508119.885

... More
code28 - For Cellar Floor Consider 50% rate on concrete rate for Shuttering Qty of CF roof slab,sump tank, septic tank & Storm water drain tank

293.04

3480

1019998.98

... More
code29 - For GF Consider 70% rate on concrete rate for Shuttering Qty of Coloumns from GF slab to GF roof beam

68.36

4873

333121.698

... More
code30 - For Ground Floor Consider 50% rate on concrete rate for Shuttering Qty of Ground Floor Cill

8.36

3480

29099.07

... More
code31 - For Ground Floor Consider 50% rate on concrete rate for Shuttering Qty of Staircase 1 &2 From GF to FF

11.4

3480

39680.55

... More
code32 - For Ground Floor Consider 45% rate on concrete rate for Shuttering Qty of GF Chejja

5.16

3132

16164.6288

... More
code33 - For GF Consider 60% rate on concrete rate for Shuttering Qty of Ground Floor Lintel & Roof beam

157.162

4176

656449.9578

... More
code34 - For Ground Floor Consider 50% rate on concrete rate for Shuttering Qty of GF Roof slab

275.08

3480

957484.71

... More
code35 - For First Floor Consider 70% rate on concrete rate for Shuttering Qty of Columns From FF Slab to FF Roof Beam

51.9

4921

255440.382

... More
code36 - For FF Consider 50% rate on concrete rate for Shuttering Qty of FF Cill

8.01

3515

28159.5555

... More
code37 - For FF Consider 50% rate on concrete rate for Shuttering Qty of Staircase 1 &2 From FF to SF

7.79

3515

27386.1345

... More
code38 - For FF Consider 45% rate on concrete rate for Shuttering Qty of FF Chejja

4.07

3164

12877.48

... More
code39 - For FF Consider 60% rate on concrete rate for Shuttering Qty of FF Lintel & RB

122.33

4218

516068.6778

... More
code40 - For FF Consider 50% rate on concrete rate for Shuttering Qty of FF Roof slab

218.86

3515

769413.273

... More
code41 - For Second Floor Consider 70% rate on concrete rate for Shuttering Qty of Columns From SF Slab to SF Roof Beam

49.52

4970

246139.6552

... More
code42 - For SF Consider 50% rate on concrete rate for Shuttering Qty of SF Cill

8.38

3550

29752.0168

... More
code43 - For SF Consider 50% rate on concrete rate for Shuttering Qty of Staircase 1 & 2 From SF to TF

4.34

3550

15408.5624

... More
code44 - For SF Consider 45% rate on concrete rate for Shuttering Qty of SF Chejja

4.12

3195

13164.7184

... More
code45 - For SF Consider 60% rate on concrete rate for Shuttering Qty of SF Lintel & RB

112.34

4260

478616.7062

... More
code46 - For SF Consider 50% rate on concrete rate for Shuttering Qty of SF Roof slab

199.4

3550

707941.784

... More
code47 - For Terrace Floor Consider 70% rate on concrete rate for Shuttering Qty of Columns From TF Slab to TF Roof Beam

25.81

5019

129546.5844

... More
code48 - For Terrace Floor Consider 50% rate on concrete rate for Shuttering Qty of Terrace Floor Cill

1.98

3585

7098.6366

... More
code49 - For Second Floor Consider 60% rate on concrete rate for Shuttering Qty of Terrace Floor Lintel & Roof beam

20.41

4302

87807.902

... More
code50 - For Terrace Floor Consdr 50% rate on concrete rate for Shuttering Qty of TF Roof slab

30.97

3585

111032.7149

... More
code51 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Common SR 2023-24 Item No. 2.11a, Page No. 18 Vol-01)

184.7309

93929

17351745.727365

... More
code52 - Ground Floor

42.96

93929

4035226.356

... More
code53 - First Floor

45.65

94869

4330776.6975

... More
code54 - Second Floor

41.6948

95808

3994714.16106

... More
code55 - Terrace Floor

9.3772

96747

907223.0013

... More
code56 - Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.(common SR Vol-1 Item no-1.11 Page 7)

795.97

454

361887.7605

... More
code57 - Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage harges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (Common SR 2023-24 Item No. 6.1, Pg No 13 Vol-02)

37.07

8631

319951.17

... More
code58 - Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (Common SR 2023-24 Item No. 6.7, Page No. 13 Vol-02)

347.13

8621

2992798.6515

... More
code59 - First floor

202.69

8707

1764977.9013

... More
code60 - Second floor

213.38

8793

1876459.4524

... More
code61 - Terrace floor

132.2

8880

1173962.44

... More
code62 - Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer (Common SR 23-24 Item- 6.15,Pg No 14 Vol-02)

103.95

1084

112749.3675

... More
code63 - Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Common SR 2023-24 Item No. 8.1.2, Page No. 41 Vol-02) .For concrete surface

3431.24

253

868275.282

... More
code64 - Ground Floor

2151.46

253

544426.953

... More
code65 - First Floor

2143.06

255

547723.2748

... More
code66 - second floor

2103.16

258

542846.6276

... More
code67 - Terrace Floor

585.96

260

152724.6144

... More
code68 - Providing 12 mm cement plaster with cement mortar 1:4 (1 cement 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Pg-41 item-8.1.1 vol-II

270.95

267

72546.8625

... More
code69 - II) Ground floor-Walls

3087.79

267

826755.7725

... More
code70 - FF Walls

1619.59

270

437985.7237

... More
code71 - SF Walls

1546.53

273

422372.8083

... More
code72 - Terrace Floor Walls

599.72

275

165390.7816

... More
code73 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Common SR 2023-24 Item 8.2.1, Page 41 Vol-02) For External Plastering Cellar Floor

290.44

309

89963.79

... More
code74 - For GF

2173.66

309

673291.185

... More
code75 - For FF

829.71

312

259574.7735

... More
code76 - For SF

611.73

316

193306.68

... More
code77 - For Terrace Floor

1015.48

319

323978.7392

... More
code78 - Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 150mm wide (Common SR 2023-24 Item No. 8.16.2, Page No. 43 Vol-02) GF

1140.46

39

45504.354

... More
code79 - First floor

900

40

36270

... More
code80 - Second floor

902

40

36711.4

... More
code81 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding (Common SR 2023-24 Item No. 11.34A, Page No. 86 Vol-02) Cellar floor

2443.73

176

431073.972

... More
code82 - Ground floor

3911.36

176

689963.904

... More
code83 - First floor

2835

178

505083.6

... More
code84 - Second floor

3416.18

179

614673.2674

... More
code85 - Terrace floor

236.25

181

42924.2625

... More
code86 - Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 1000x1000 mm(Common SR 2023-24 Item No. 9.12.4, Page No. 60 Vol-02) Cellar floor

121.3

1925

233587.41

... More
code87 - Ground floor

1859.34

1925

3580531.038

... More
code88 - First floor

894.69

1944

1740136.2624

... More
code89 - Second floor

830.41

1964

1631099.6261

... More
code90 - Terrace floor

100.14

1983

198624.6858

... More
code91 - 9.24 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all omplete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent (Common SR 2023-24 Item No. 9.24, Page No. 63 Vol-02) Cellar floor

41.94

2994

125593.524

... More
code92 - Ground floor

811.83

2994

2431106.118

... More
code93 - First floor

483.79

3024

1463247.0445

... More
code94 - Second floor

487.77

3054

1489888.5873

... More
code95 - Terrace Floor

68.15

3084

210204.586

... More
code96 - Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.(Common SR 2023-24 Item No. 10.2,Page-69 Vol-02) Cellar floor

64.35

344

22162.14

... More
code97 - Ground floor

639.88

344

220374.672

... More
code98 - First floor

321.96

347

111990.5664

... More
code99 - Second floor

326.86

351

114822.6494

... More
code100 - Terrace floor

135.66

354

48122.6718

... More
code101 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. (Common SR 2023-24 Item No. 9.9, Page No. 60 Vol-02) Ground floor

109.8

1129

124052.04

... More
code102 - First floor

100.3

1141

114452.33

... More
code103 - Second floor

123.75

1152

142609.5

... More
code104 - Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete. (Common SR 2023-24 Item No. 9.10, Page No. 60 Vol-02) Ground floor

329.57

1161

382729.641

... More
code105 - First floor

221.21

1172

259459.4211

... More
code106 - Second floor

323.69

1184

383420.5157

... More
code107 - Providing Honne wood frames of doors, windows, clerestory windows,ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (Common SR 2023-24 Item No. 12.11, Page No. 100 Vol-02) Cellar floor

0.18

144977

26095.986

... More
code108 - Ground floor

5.74

144977

832171.998

... More
code109 - First floor

1.89

146427

276747.9372

... More
code110 - Second floor

1.98

147877

292796.955

... More
code111 - Terrace floor

0.09

149327

13439.4327

... More
code112 - Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. Size 62 x 125mm (Fixtures shall be paid for separately) (Common SR 2023-24 Item -12.93.2, Pg-111 Vol-02) Ground floor

57.75

802

46327.05

... More
code113 - First floor

36.75

810

29775.585

... More
code114 - Second floor

52.5

818

42957.6

... More
code115 - Providing and fixing factory made Green certified, Anti Termite, UV resistant,high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) Size 30mm thick (Common SR 2023-24 Item No. 12.94.1, Page No. 112 Vol-02) Ground floor

16.66

3659

60963.105

... More
code116 - First floor

11.03

3695

40765.1152

... More
code117 - Second floor

15.75

3732

58785.93

... More
code118 - Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. (Common SR 2023-24 Item No. 12.51.1, Page No. 104 Vol-02) Cellar floor

2

1066

2133.6

... More
code119 - Ground floor

47

1066

50139.6

... More
code120 - First floor

28

1077

30169.16

... More
code121 - Second floor

32

1088

34820.48

... More
code122 - Terrace floor

3

1098

3296.4

... More
code123 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. 35 mm thick both side Teak ( excluding cost of fixtures ) (Common SR 2023-24 Item No. 12.57.4, Page No. 105 Vol-02) Cellar floor

5.04

4758

23983.344

... More
code124 - Ground floor

68.41

4758

325535.826

... More
code125 - First floor

46.31

4806

222574.6589

... More
code126 - Second floor

48.51

4853

235456.3827

... More
code127 - Terrace floor

2.21

4901

10832.0056

... More
code128 - Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Common SR 2023-24 Item No. 8.51, Page No. 50 Vol-02) CF

3702.19

105

388729.95

... More
code129 - Ground floor

5239.25

105

550121.25

... More
code130 - First floor

3658.28

106

387960.594

... More
code131 - Second floor

3585.22

107

383977.062

... More
code132 - Terrace floor

1185.68

108

128231.292

... More
code133 - Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Common SR 2023-24 Item No. 8.27, Page No. 45 Vol-02) Cellar floor

3702.19

55

206026.8735

... More
code134 - Ground floor

5271.25

55

293345.0625

... More
code135 - First floor

3658.28

56

205631.9188

... More
code136 - Second floor

3585.22

56

203497.0872

... More
code137 - Terrace floor

1185.68

57

67963.1776

... More
code138 - Wall painting with premium acrylic emulsion paint of interior grade,having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. (Common SR 2023-24 Item No. 8.54.2, Page No. 50 Vol-02) Cellar floor

3702.19

115

427602.945

... More
code139 - Ground floor

5239.25

115

605133.375

... More
code140 - First floor

3658.28

116

426774.9448

... More
code141 - Second floor

3585.22

117

422374.7682

... More
code142 - Terrace floor

1185.68

118

141060.3496

... More
code143 - Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Common SR 2023-24 Item No. 8.31, Page 46 Vol-02) Cellar floor

290.44

186

54283.236

... More
code144 - Ground Floor

1366.08

186

255320.352

... More
code145 - First Floor

829.71

188

156624.3567

... More
code146 - Second Floor

611.73

190

116620.2072

... More
code147 - Terrace Floor

1015.48

192

195490.0548

... More
code148 - Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge. (Common SR 2023-24 Item No. 8.55.1, Page No. 50 Vol-02) Cellar floor'

6.05

58

355.74

... More
code149 - Ground floor

289.01

58

16993.788

... More
code150 - First floor

157.25

59

9339.0775

... More
code151 - Second floor

171.94

59

10312.9612

... More
code152 - Terrace floor

12.1

60

732.776

... More
code153 - Painting with synthetic enamel paint of approved brand & manufacture to give an even shade :2 coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops & foreign matter including preparing the surface even & sand paper smooth,cost of materials,labour complete as per specifications & as per directions of Engineer-in-charge. (Common SR 2023-24 Item 8.40,Pg48 Vol-02) Cellar floor

227.11

120

27423.5325

... More
code154 - Ground floor

598.16

120

72227.82

... More
code155 - First floor

478.55

121

58363.958

... More
code156 - Second floor

501.61

123

61783.3037

... More
code157 - Terrace floor

39.1

124

4862.867

... More
code158 - Providing & fixing Stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Common SR 23-24 Item 11.28, Page 85 Vol-02) Cellar floor

542.52

593

321849.99

... More
code159 - Ground floor

1473.9

593

874391.175

... More
code160 - First floor

1678.2

599

1005543.876

... More
code161 - Second floor

1209.6

605

731953.152

... More
code162 - Terrace floor

248.64

611

151931.472

... More
code163 - Polyurethane based Single Component for New Surface Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the wa terproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. (Common SR 23-24 Item 15.1, Pg 148 Vol-02) GF

124.88

857

107128.308

... More
code164 - First floor

118.5

866

102671.955

... More
code165 - Second floor

140.96

875

123341.4096

... More
code166 - Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277,in 240 mpa steel rade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trussesand including cutting to size and shape wherever required. (Common SR 2023-24 Item 7.38, Page 26 Vol-02)

33.85

596

20188.14

... More
code167 - providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated Storm water drain and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (Common SR 23-24 Item 12.90,Pg No. 110 Vol-02) Ground floor

161.82

7070

1144180.674

... More
code168 - First floor

135

7141

964090.35

... More
code169 - Second floor

135

7212

973634.85

... More
code170 - Terrace floor

11.25

7282

81931.725

... More
code171 - Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated Storm water drain and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (Common SR 2023-24 Item No. 12.85, Page No. 109 Vol-02) Ground floor

8.24

6004

49480.788

... More
code172 - First floor

6.75

6065

40938.75

... More
code173 - Second floor

8.78

6125

53777.939

... More
code174 - Providing & fixing Vertical Blinds of reputed make of shape 100mm regular fabric with powder coated aluminium channel, telting with PVC Chain system with all necessary fittings and fixtures as per direction of Engineer in charge (Common SR 2023-24 Item No. 22.23, Page No. 219 Vol-02) Ground floor

205.78

892

183658.65

... More
code175 - First floor

175.06

901

157804.3358

... More
code176 - Second floor

175.06

910

159365.871

... More
code177 - Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resist x005f ance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sand wiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete (Common SR 23-24 Item 10.15 Pg71 Vol-02) GF

173.21

4188

725481.4245

... More
code178 - First floor

148.51

4230

628246.3083

... More
code179 - Second floor

126.87

4272

542016.5514

... More
code180 - Front Elevation

82.54

4314

356085.814

... More
code181 - Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(Common SR 23-24 Item 8.29 Pg 45 Vol-02) Ground floor

11.46

297

3405.339

... More
code182 - Second floor

121.32

303

36770.8788

... More
code183 - Providing & fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters & partition frames with C.P. brass/stainless steel screws etc. complete as per architectural drawings & directions of engineer- in-charge: Pre-laminated particle board with decorative lamination on both sides including cost of materials, labour, usage charges of machinery complete as per specifications & as per directions of the Engineer-in-Charge. PWD S.R 2023-24,Vol-2, P.No.89, Item No.11.36.2

188.64

1032

194704.776

... More
code184 - First Floor

164.35

1042

171329.9445

... More
code185 - Second floor

126.17

1052

132830.5143

... More
code186 - Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.(PWD Common S.R 2023-24, Vol-2, P.No.88, Item No.11..35.2 ) Ground floor

663.19

599

397615.5645

... More
code187 - First Floor

633.77

605

383779.4235

... More
code188 - Second floor

421.59

611

257819.1486

... More
code189 - Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ sqm) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(PWD Common S.R 2023-24, Vol-2, P.No.89, Item No.11..37.1 ) Ground floor

106.62

1037

110607.588

... More
code190 - First Floor

72.58

1047

76047.1466

... More
code191 - Second floor

55.33

1058

58547.4395

... More
code192 - Providing and supplying aluminium extruded tubular and other alu minium sections as per the architectural drawings and approved draw ings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment.(PWD Common S.R 2023-24, Vol-2, P.No.181, Item No.18.1 ) Ground floor

101.7

427

43461.495

... More
code193 - First Floor

108.9

431

47003.418

... More
code194 - Second Floor

108.9

435

47469.51

... More
code195 - Terrace Floor

29.7

440

13073.049

... More
code196 - Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.(PWD Common S.R 2023-24, Vol-2, Pg.No.183, Item No.18.3 ) Ground floor

26.1

3195

83393.415

... More
code197 - First Floor

29.7

3227

95844.87

... More
code198 - Second Floor

29.7

3259

96793.785

... More
code199 - Terrace Floor

8.1

3291

26657.1

... More
code200 - Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings & as directed by Engineer-in-Charge.(PWD Common S.R2023-24, Vol-2, P.No.28, Item No.7.41)GF

150.12

1777

266860.818

... More
code201 - First Floor E.E

175.32

1795

314774.7876

... More
code202 - Second Floor S.E.E

303.65

1813

550578.18

... More
code203 - Providing and fixing in wall lining flat pressed three layer (medium den sity) particle board or graded wood Pre-laminated one side decorative lamination and other side balancing lamination Grade I, Type II, IS : 12823 marked, including priming coat on unexposed arrangement and screws etc. complete.(PWD Common S.R 2023-24, Vol-2, P.No.70, Item No.10.1) Size 12mm thick Ground floor

67.5

1164

78600.375

... More
code204 - First floor

137.57

1176

161794.7013

... More
code205 - Second Floor S.E.E

289.71

1813

525302.172

... More
code206 - Providing and fixing plywood 4 mm thick, one side decorative veneer conforming to IS: 1328 (type-1), for plain lining / cladding with necessary screws, including priming coat on unexposed surface with Decorative veneer facings of approved manufacture (PWD common S.R 2023-24, Vol-2, P.No.70, Item No.10.11 ) Ground Floor

67.5

1554

104895

... More
code207 - First Floor

137.57

1569

215921.6178

... More
code208 - Second floor

289.71

1585

459213.5268

... More
code209 - Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge. (Common SR 2023-24 Item No. 11.5.1, Page No. 77 Vol-02) Terrace floor

7.56

4701

35546.364

... More
code210 - UG Sump Tanks Providing & Applying Crystalline waterproofing slurry coat RCC structure like Retaining wall, Underground tank. The material having chemical resistance properties, seals shrinkage cracks up to 0.4 mm width, capable of preventing water dampness & seepages, Water permeability is Nil confirms to BS EN 12390 Part 8: 2000. Powder to water mixed at a ratio (5:2) 5 parts powder and 2 parts water, applied @ 1.5kg/m2 in 2 coats to achieve 1.0mm DFT on a cleaned surface free from all loose materials etc., complete. The finished cost to include surface preparation completely as per specification. (Common SR 2023-24 Item No. 15.23, Page No. 155 Vol-02)

245.35

2572

631162.875

... More
code211 - Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.(Common SR 2023-24 Item No. 9.25, Page No. 63 Vol-02)

910.31

840

764660.4

... More
code212 - Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 600 x 300 x 150 mm size (Common SR 2023-24 Item No. 8.42.3, Page No. 73 Vol-03)

204.22

486

99281.553

... More
code213 - Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.(Common SR 2023-24 Item No. 12.59, Page No. 105 Vol-02)

77

1169

90066.9

... More
code214 - Providing and fixing 6mm Clear/opal white/solar bronze/blue/green tinted Multi wall poly carbonate sheet for Tubular structure. The work including cost of all materials, labour charges and usage charges of machinery for cutting, welding, grinding and erection equipments, with all lead, transportation, loading and unloading and all other incidental charges etc. complete as per specification and directions of the Engineer in charge of the work.(Common SR 2023-24 Item No. 7.34, Page No. 26 Vol-02)

564

3281

1850625

... More
code215 - Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Common SR 2023-24 Item No. 11.16.1, Page No. 82 Vol-02)

16380

142

2339064

... More
code216 - Providing and fixing plain rolled glass 4mm thick with teakwood beading of 10mm thick (Common SR 2023-24 Item No. 20.107, Page No. 207 Vol-02)

25.47

1204

30674.7945

... More
code217 - Providing and fixing Brass Fixtures as per direction of engineer in chargeAs per Market rate Front Main Door Handle-24"

4

6750

27000

... More
code218 - Heavy Aldrop-14"

2

4243

8487.5

... More
code219 - Stoppers-5"

4

1187

4750

... More
code220 - Interlock

2

4700

9400

... More
code221 - Towebolt-8"

8

1725

13800

... More
code222 - Towebolt-4"

12

625

7500

... More
code223 - Heavy Lach-12"

2

1937

3875

... More
code224 - Hinges-5"

8

625

5000

... More
code225 - Hinges-3"

24

312

7500

... More
code226 - Godrej Navtal/Link Locks Door

60

750

45000

... More
code227 - Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge (Common SR 2023-24 Item No. 20.107, Page No. 218 Vol-02) SS Handles 300mm BR 550

212

550

116600

... More
code228 - SS Aldrop 16mm dia, 300mm BR 375

106

375

39750

... More
code229 - SS Tower Bolts 250x10mm BR=200

106

200

21200

... More
code230 - SS hinges 125 mm BR-50

404

50

20200

... More
code231 - SS Door stopper 75mm.BR=100

100

100

10000

... More
code232 - Concealed Conduit System:Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary( P no 2 item no 1.2.1,1.2.2,1.2.3) 19/20 mm dia 2 mm thick

5231

66

345246

... More
code233 - 25 mm dia 2 mm thick

1775

78

138450

... More
code234 - 32 mm dia 2.5 mm thick

170

103

17510

... More
code235 - Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.(P No 2 Item no 1.4.1 ,1.4.2,)

35

106

3710

... More
code236 - 100 x 75 x 65 mm

35

118

4130

... More
code237 - Supplying & fixing PVC/metal conduit Deep junction box (Pg 2/3 Item No 1.5.1,1.5.2,) 19/20 mm deep Junction box

1121

49

54929

... More
code238 - 25 mm deep Junction box

175

56

9800

... More
code239 - 32 mm deep Junction box

70

61

4270

... More
code240 - Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete (Pno 3 Item No 1.7.1/1.7.2, 75 x 75 x 65 mm

2400

29

69600

... More
code241 - upto 50 mm conduit in CC floor

700

69

48300

... More
code242 - supplying & fixing MS fan box with round Hook(Pg 4 Item 1.13)

290

117

33930

... More
code243 - Supply & laying of under floor junction boxes shall be of three-piece construction - Base box, frame and load plate. Base box shall be robust in its construction manufactured from 1.5 mm thick zero spangle pre- galvanized sheet steel with 275 GSM ( 36.67 microns) coating mass. The load plate and frame thicknesses shall be 3 mm and 2 mm respectively to provide adequate load bearing capacity of 5 kN with deflection not greater than 6mm while loading and permanent deflection not exceeding 3 mm as per EN 50085-2-2. The trap and frame shall be Epoxy coated to protect from corrosion. The junction boxes shall be 10 mm or 20 mm recess to accommodate floor covering suitable for Tile/Carpet/marble / granite/ according to site conditions. The junction box has height of 60mm up to finished floor level. The base of junction boxes should have pre-punched sealing arrangements on all four sides to accept either 25 mm or 38 mm of metal raceways.(Pno 4 Item no 1.15.1) For (50-100x38mm) duct.Dim:172x172x60mm. 10 mm Recess (CF-0,GF-4,FF-4,SF-4

14

1736

24304

... More
code244 - supplying and wiring adopting loop system in existing PVC conduit /casing caping using 2x1.5 sq mm ( phase & nuetral ) 1x1.0 sq mm ( Earth wire ) FRLS multi strand PVC isulated copper wire ( confirming to IS 694 and latest amendments ) without control switch shall be fixed on the existing plastick sheet /gang box the other end of the wires shall be terminated with sufficiant loose length in awood/PVC round block complete for each outlet ( Pno 5 Item no 2.2.1, 2.2.2, 2.2.3, 2.2.4) Short point upto 3Mtr from tapping point to out let via switch box (CF-10,GF-40,FF-40,SF-40

170

269

45730

... More
code245 - Medium point above 3Mtr upto 6Mt from tapping point to outlet via switch box (CF-30,GF-65,FF-65,SF-65

245

379

92855

... More
code246 - Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box (CF-40,GF-250,FF-250,SF-250

805

555

446775

... More
code247 - Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to out let via switches (CF-8,GF-30,FF-30,SF-30

98

677

66346

... More
code248 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694-2010 ( Pno 5 Item No 2.3.2 to 2.3.5) 1.5 sq mm

7636

26

198536

... More
code249 - 2.5 sq mm

14655

42

615510

... More
code250 - 4 sq mm

4150

63

261450

... More
code251 - 6 sq mm

710

92

65320

... More
code252 - Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 (Pno 8 Item no 3.1.1) 6 Amps 2 way (CF-0,GF-6,FF-6,SF-6

68

128

8704

... More
code253 - Supplying and fixing Powder coated/galvanised metal box suitable for mounting modular switch plates The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, including necessary rawl plugs,Machine/NF screws etc., complete.(Pno 8 ) 1 to 2 way Item no-3.4.1

44

138

6072

... More
code254 - 4 to 5 way Item no-3.4.3

33

177

5841

... More
code255 - 6 way Item no-3.4.4

49

220

10780

... More
code256 - 10 -12 way Item no-3.4.6

143

319

45617

... More
code257 - 18 way Item no-3.4.8

50

405

20250

... More
code258 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the( P no 8 1 to 2 Module Item no 3.5.1

44

137

6028

... More
code259 - 4 module Item no 3.5.3

33

161

5313

... More
code260 - 6 module Item no 3.5.4

49

234

11466

... More
code261 - 10-12 module Item no 3.5.6

143

344

49192

... More
code262 - 18 module Item no 3.5.8

50

457

22850

... More
code263 - Supplying and fixing of modular switch & connected accessories onexisting modular switch plate as per IS 3854 and IS 1293.) ( Pg no 9) 6A one way switch Item no-3.6.1

1425

102

145350

... More
code264 - 6 A two way switch Item no-3.6.2

97

166

16102

... More
code265 - 6 A three way socket Item no-3.6.3

620

171

106020

... More
code266 - steped fan regulater Two module Item no-3.6.4

393

357

140301

... More
code267 - 16 A one way switch Item no-3.6.7

86

180

15480

... More
code268 - 6 A bell push Item no-3.6.8

66

177

11682

... More
code269 - 32 A DP Switch Item no-3.6.9

16

326

5216

... More
code270 - 6/16 universal socket Item no-3.6.10

86

236

20296

... More
code271 - TV/telephone socket Item no-3.6.11

47

156

7332

... More
code272 - RJ 45/1.0 outlet cat 6 Item no-3.6.12

85

337

28645

... More
code273 - Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board.)( Pno 10 Item No 3.14.5/3.14.6/3.14.7/3.14.8) 6A Bakelite ceiling rose Item-3.14.5

635

78

49530

... More
code274 - 6A Pendent holder Item-3.14.6

85

71

6035

... More
code275 - 6A Batten holder Item-3.14.7

200

74

14800

... More
code276 - 6A Bell buzzer Item-3.14.9

66

130

8580

... More
code277 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechnism FOUR POLE 160 A 25 KA( Pno 16&17 Item No 5.15.11) (CF-0,GF-1,FF-1,SF-1)

8

13447

107576

... More
code278 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required ( PNo 17 Item No 5.18.1/5.18.4/5.18.7/5.18.8) 6 to 32 A SP MCB Item No-5.18.1

35

415

14525

... More
code279 - 6 to 32 a DP MCB Item No-5.18.4

124

739

91636

... More
code280 - 6 to 32 A TPN Item No-5.18.7

41

1717

70397

... More
code281 - Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS encloser (Pno 18 Item No 5.19.9/5.19.11) 12 way SP& N double door

40

2329

93160

... More
code282 - 4 way TP&N double door

26

4038

104988

... More
code283 - Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail /flush mounting on panel board ( P no 18 iTEM No 5.21)

4

9255

37020

... More
code284 - Supplying, fixing and wiring rotary selector switch suitable for fvoltmeter ( Pno 19 Item no 5.28

4

160

640

... More
code285 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C confirming IEC 60898 ( Pno 19 Item no 5.38 (

11

515

5665

... More
code286 - Supplying 100 A 4X 30X 6mm allimiuim strips rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per ISspecification with necessary bolts, nuts and washers etc., complete( Pno 20 Item No 5.40.1)

5.5

2465

13557.5

... More
code287 - Fabricating supplying and mounting MS box made out 16 SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete..(Pno 20 Item No 5.42.2) (CF-0,GF-34000,FF-34000,SF-34000

107000

-

46010

... More
code288 - Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete.12" Sweep (300 mm)P-30 Item 6.2.1(CF-0,GF-6,FF-6,SF-8

25

2969

74225

... More
code289 - Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 & with double ball bearing system ( Pno 30 Iten No 6.3.1)48" Sweep (1200 mm) Regular model (CF-2,GF-60,FF-60,SF-60

208

2984

620672

... More
code290 - Supplying wall mounting fan suitable to operate at single- phase 230v AC. supply.(Pno-30 Item no-6.5.2)400 mm Sweep (CF-0,GF-2,FF-2,SF-3

12

3212

38544

... More
code291 - Supplying of .. TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless removet unit ( Pno 31 Item No 6.8.6) 5Star CAPACITY 2.0 ton (CF-0,GF-0,FF-4,SF-2+1+1 Meeting hall-4)

13

67399

876187

... More
code292 - Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C ( Pno 32 Item No 6.12)

13

3175

41275

... More
code293 - Supplying and drawing UTP-CAT 6E LAN cable. (Pg no-36, Item no8.1) (CF-0,GF-1000,FF-2000,SF-3000

6100

38

231800

... More
code294 - Supplying and drawing PVC flexible one pair telephone narmoured tinned copper cable 20 piar ( Pno 36 Item No 8.2.7) (CF-0,GF-200,FF-200,SF-200

625

150

93750

... More
code295 - Supplying & Fixing of switch mounting rack with power manager & cable manager 4U with 450 mm depth ( P no 36 Item No 8.4.1 (CF-0,GF-1,FF-1,SF-1

4

4892

19568

... More
code296 - supplying & fixing of 1/0 socket with box ) Pno 36 Item 8.10.1 (CF-0,GF-80,FF-80,SF-80

245

490

120050

... More
code297 - 1.1 KV XLPE heat resistent PVC insulated inner sheet armoured LTUG cable as per IS -1554 ( part 1or IS 7038 part-1 armouring strip thickness and resistivity as per IS 3975 70 sq mm 3.5 core 18 GI strip -4x0.8 mm ( Page 9 Iten No 223/18.13) ESCOM SR GF-25,FF-40,SF-50

0.14

317912

44507.68

... More
code298 - Supplying, erecting, testing and commissioning of voltage stabilizer suitable for 170 to 270 v input and load variation from no load to full load, with over load protection, spike suppression,operating at 00 C to 400 C. Range etc., complete. 3KVA capacity ( Pno 38 Item No 9.1.1) Qty same as Ac;s

13

3995

51935

... More
code299 - Supplying,erecting,testing & commissioning of OFF- LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with all accessories complete Excluding batteries and wiring complete.3 kVA OFF LINE UPS for GF-1 FF-1 SF-1 (pg no-38 Item no-9.2.4

4

29142

116568

... More
code300 - Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries (pg no-38 Item no-9.5.10.For 200AH capacity Qty as UPS

4

20668

82672

... More
code301 - 10. 1 Supplying, installing, testing and commissioning of Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514/ISO 3046/ ISO 8528 & IS 1002/ISO 3046 Generator set specifications.Engine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class.Spin-on lube oil filter, Spin-on dual fuel filter with water separator,Turbocharger, Charge air cooler, Silencer (Hospital grade), Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing,First fill of lube oil and coolant, Safety for low lube oil pressure,Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation 10.1.7 62.5KVA/50kw

1

641071

641071

... More
code302 - Providing 66KV,1250A,40KA,Single phase,SF6 Gas Insulated bis duct (GIB) outside GIS Hall alongwith associated support structure.Si.No-31.D.ii of volume-6 KPWD SR 2023-24 pfg no-132

30

3279

98370

... More
code303 - supplying ... feet PVC batten with integrated LED tube ... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220- 240V@ 50/60Hz & Power factor greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 20/22 1x4" -20/22 W (Pno 43 Item no 11.3.2) (CF-40,GF-250,FF-250,SF-250

840

690

579600

... More
code304 - Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @50/60Hz & Power factor greater than0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition LES squire /round down light 15-18 W ( Pno 44 Item no 11.5.3)(CF-0,GF-20,FF-20,SF-20

69

1324

91356

... More
code305 - Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiencygreater than1301m/w, nominal CRI greater than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/ Nichia/ Lumileds/Osram make LED Source.LED Streetlight 25W (46/46 Item 11.8.1

24

2425

58200

... More
code306 - Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.( Pno 56 Item No 13.5) (CF-40,GF-270,FF-270,SF-270

850

162

137700

... More
code307 - Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring complete (Pg no 57 Item13.10 CF-6 GF-94,FF-94,SF-94

318

171

54378

... More
code308 - Supplying and Fixing ofUsing 32mm dia G.I.Pip mm dia class A GI pipe bracket upto 2ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires.( Pno 56 Item No 13.1.2)

19

1045

19855

... More
code309 - Fabricating supplying and mounting MS box made out 18 SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint & finally finished with approved colour etc.,complete.(Pno 20 Item 5.42.2)

135000

-

58050

... More
code310 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechnism FOUR POLE 160 A 25 KA( Pno 16&17 Item No 5.15.1/5.15.16) FOUR POLE 160 A 25 KA

4

13447

53788

... More
code311 - FOUR POLE 400 A 36 KA

1

28216

28216

... More
code312 - supplying and fixing shunt trip suitable for MCCB CBCT (PNo 17 Item No 5.16

1

1703

1703

... More
code313 - Supplying, fixing & wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail /flush mounting on panel board ( P no 18 iTEM No 5.21)

1

9255

9255

... More
code314 - Supplying 100 A 4X 30X 6mm allimiuim strips rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve,mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming & outgoing cables as per IS specification with necessary bolts, nuts & washers etc., complete( Pno 20 Item No 5.40.3)

2

4445

8890

... More
code315 - Supplying,fixing & wiring rotary selector switch suitable for voltmeter(Pg 19 Item 5.28)

1

160

160

... More
code316 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C confirming IEC 60898(Pg 19 Item No 5.38)

3

515

1545

... More
code317 - Supplying,fixing & wiring 3-Phase Digital Ammeter/voltmeter (P No 19 Item No 5.29)

2

1425

2850

... More
code318 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required ( PNo 17 Item No 5.18.1/5.18.4/5.18.7/5.18.8) 6 to 32 A SP MCB

3

415

1245

... More
code319 - 6 to 32 A DP MCB

2

739

1478

... More
code320 - 6 to 32 A TPN

4

1717

6868

... More
code321 - Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia (Pg no-54,item no-12.56)

12

4150

49800

... More
code322 - Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia (Pg no-54,item no-12.56)

4

3510

14040

... More
code323 - Design, supplying, erecting testing and commissioning of 8- Passenger/ Bed-cum-passenger hospital lift with speed of 1mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 V 3 phase 50 cycles AC supply, powder coated / Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED car illumination, emergency light,intercom and fan as desired by the user, central opening / side opening door with or without attendant operation, 7 segment display buttons,call register indicator, fireman drive, SS handrails inside car, full length infrared curtain in car door, automatic rescue device with batteries,voice announcing in regional/ international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding andminor civil works like fixing of guide rail, counter weight etc.,The total product and services shall adhere to IS 14665/2016 ( with latest amendments) part/section 1 to 5 with regards to general guidelines of fire safety rated doors, MRLL beams, pressure switch, manual change over for doors during emergency, ARD of 10 times with sufficient battery back up and standard dimensions of chair car and door openings for all sizes and capacities of lifts including fitness certificate and duly observing all other safety norms prescribed and adhere to CPWD specifications, PCB Norms, National Electricity Code (NEC), NBC-2016, IEC and Karnataka State Lifts, Escalators and Passengers Conveyers Act 2012 and Rules 2014. The Supplier shall be registered in Government Electrical Inspectorate in the State of Karnataka (P No-59 Item no-14.4.2 Without Machine room of SS Finish of Capacity-8passenger 5 stops

2

1592677

3185355.76

... More
code324 - Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.(Pg no-54,item no-12.57)

3

4256

12768

... More
code325 - Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing & technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m (Common SR 2023-24 Item No. 1.6.1 Page No.6 Vol-01)

41.4

508

21039.48

... More
code326 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) 50 mm nominal dia Pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work(Common SR 2023-24 Item No. 13.33.6, Page No. 122 Vol-02)

210

757

158980.5

... More
code327 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) 32 mm nominal dia Pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work(Common SR 2023-24 Item No. 13.33.4, Page No. 122 Vol-02)

315

390

123039

... More
code328 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) 25 mm nominal dia pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. (Common SR 2023-24 Item No. 13.32.3, Page No. 122 Vol-02)

190

500

95161.5

... More
code329 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) 20 mm nominal dia pipes, having thermal stability for hot & cold water supply, including all CPVC lain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. (Common SR 2023-24 Item No. 13.32.2, Page No. 122 Vol-02)

250

397

99487.5

... More
code330 - Providing & fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end):32 mm nominal bore(Common SR 23-24 Item 13.4.2, Page. 117 Vol-02)

14

627

8790.6

... More
code331 - Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 Common SR 2023-24 Item No. 13.12, Page No. 119 Vol-02)

40

666

26670

... More
code332 - Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (Common SR 2023-24 Item No. 13.34, Page No. 123 Vol-02)

11500

9

108675

... More
code333 - Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.Item no-13.37 Pg no-123

18

328

5915.7

... More
code334 - Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber 100mm x 100mm size P type with Non Modular common burnt clay bricks of designation 3.5& water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design (Common SR 23-24 Item 13.38, Page No. 123 Vol-02)

7

2658

18610.2

... More
code335 - Constructing brick masonry chamber for underground C.I. inspection chamber & bends with bricks in CM 1:4 (1cem: 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions,total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg & weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cem :1.5 fine sand :3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1cem:5 fine sand:10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with CM 1:3 (1cem:3 coarse sand), finished smooth with a floating coat of neat cement on walls & bed concrete etc.complete as per standrd design: Inside dimensns 455x610 mm & 45 cm deep for single pipe line :With common burnt clay (non modular) bricks of class desgntn 3.5.SR 23-24 Item13.53, P 126 Vol-2

13

5924

77013.3

... More
code336 - Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 600X850 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. (Common SR 2023-24 Item No. 13.55, Page No. 127 Vol-02)

2

7771

15542.1

... More
code337 - Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete (Common SR 2023-24 Item No. 13.59, Page No. 127 Vol-02)

70

231

16170

... More
code338 - Providing & fixing PVC (S.W.R) S Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete (Common SR 2023-24 Item 13.62, Page-127 Vol-02)

14

375

5262.6

... More
code339 - Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete (Common SR 2023-24 Item No. 13.63, Page No. 128 Vol-02)

63

256

16140.6

... More
code340 - Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests(Common SR 2023-24 Item 14.1.1, Page. 131 Vol-02)

15

5128

76923

... More
code341 - Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid(Common SR 2023-24 Item No. 14.2.1, Pg No.131 Vol-02)

17

5079

86358.3

... More
code342 - Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :Single half stall urinal with 5 litre P.V.C. automatic flushing cistern(Common SR 2023-24 Item No. 14.5.1, Page No. 132 Vol-02)

18

9074

163333.8

... More
code343 - Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever equire:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps(Common SR 2023-24 Item No. 14.7.1, Page No. 132 Vol-02)

25

3236

80902.5

... More
code344 - 14.8 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings (Common SR 2023-24 Item No. 14.8, Page No. 132 Vol-02)

25

1494

37353.75

... More
code345 - Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :610x510 mm bowl depth 200 mm (Common SR 2023-24 Item No. 14.10.2.1, Page No. 134 Vol-02)

3

3806

11418.75

... More
code346 - Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. (Common SR 2023-24 Item No. 14.16A, Page No. 134 Vol-02)

18

285

5140.8

... More
code347 - Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete Item no-14.28.2.1 pg no-136 For 32mm ida

8

96

772.8

... More
code348 - Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm(Common SR 2023-24 Item No. 14.32.2, Page No. 136 Vol-02)

25

1068

26722.5

... More
code349 - 600 mm long towel rail with total length of 645 mm, width 78 mm & effective height of 88 mm, weighing not less than 190 g.(Common SR 23-24 Item-14.40.2, Page 137 Vol-02)

25

520

13020

... More
code350 - Providing and fixing Angle cock light with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy (Common SR 2023-24 Item No. 14.52a, Page No. 139 Vol-02)

25

630

15750

... More
code351 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 75mm dia., 6 kg/sqcm & class 3 (Common SR 23-24 Item 10.1.5,Page113 Vol-05)

125

231

28875

... More
code352 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 90mm dia., 6 kg/sqcm & class 3 (Common SR 23-24 Item 10.1.6,Pg 113 Vol-02)

320

308

98784

... More
code353 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 110mm dia.,6 kg/sqcm & class 3 (Common SR 23-24 Item-10.1.7 Pg 113 Vol-05)

450

431

194197.5

... More
code354 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 160mm dia., 6 kg/sqcm & class 3 (Common SR 23-24 Item10.1.9, Pg 113 Vol-05)

185

648

120046.5

... More
code355 - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m (Common SR 2023-24 Item No. 1.14.1, Page No. 8 Vol-01)

51.91

107

5559.561

... More
code356 - 1.23 Providing & Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering,including cost of all materials and labour with all lead & lift complete as per specifications.( SR Vol-1 Item no-1.23 Pg 11 )

2.19

2816

6167.259

... More
code357 - Providing & laying in position CC for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates & fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators,including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, & all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates (SR 2023-24 Item No. 2.1.3, Page No. 15 Vol-01)

3.03

6288

19054.0035

... More
code358 - Filling approved earth(excluding rock) in trenches, plinth, sides of foundations & other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming & watering, lead up to 50 m and lift upto 1.5 m.(common SR Vol-1 Item no-1.11 Pg 7

3.45

454

1568.5425

... More
code359 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (1 cement : 6 coarse sand) (Common SR 23-24 Item 1.9, Page 7 Vol-01)

38.45

279

10739.085

... More
code360 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Common SR 2023-24 Item No. 2.2.1, Page No. 15 Vol-01)

6.97

6601

46011.4095

... More
code361 - Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Common SR 2023-24 Item No. 2.4.2, Page No. 16 Vol-01)

2.66

6639

17660.139

... More
code362 - Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Common SR 2023-24 Item No. 11.16.1, Page No. 82 Vol-02)

3632.89

142

518776.692

... More
code363 - Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277,in 240 mpa steel rade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trussesand including cutting to size and shape wherever required. (Common SR 2023-24 Item 7.38, Page 26 Vol-02)

202.08

596

120520.512

... More
code364 - Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.(Common SR 2023-24 Item 9.25, Page 63 Vol-02)

161

840

135240

... More
code365 - Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 600 x 300 x 150 mm size (Common SR 2023-24 Item No. 8.42.3, Page No. 73 Vol-03)

84

486

40836.6

... More
code366 - Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S,by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity & cceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal & labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden & fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M & upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry borewell towards Item-12.4 Pg no-140 Vol-5

3

5552

16657.2

... More
code367 - 12.2 Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars & cap with ncessary cutting, threading welding including transportation of rig & supporting vehicles,crew charges,cost of consumables, cost of yield test at the final depth with a minimum working of compressor for 1 hour etc.complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: (Above 300m of drilling add 10% for every 50m depth) item no-12.2.1 to 12.2.3 pg no-139

150

324

48667.5

... More
code368 - 12.2.2 Borewell depth of 50 to 100 Mtrs

150

406

60952.5

... More
code369 - 12.2.2 Borewell depth of 100 to 150 Mtrs

150

432

64890

... More
code370 - Supply of ISI mark 175mm nominal bore,plain & steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 & latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 & manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects The tube shall be responsible straightend should be with ISI marking weighng 25.10kg/m.prices include Collar-Medium duty.pg-143 item 12.32

18

2029

36533.7

... More
code371 - Providing & fixing MS casing collars as per IS 1239 (part-II)1982 with all latest amendments for any dia.The thicknes of plate used for covering 1 end shall be 3mm (min). The dimensions of caps & colars shall be strictly as per IS 1239.pg-143 item-12.33

3

157

472.5

... More
code372 - 12.34 Providing and laying at site of work MS casing caps as per IS 1239 (part II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge.pg-143 item no-12.34

3

172

516.6

... More
code373 - 10.1 Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc.PVC pipes 140mm dia,6kg/sqcm & Class-3 item no-10.1.8 pg no-113

355

613

217686

... More
code374 - Providing,laying & jointing HDPE pipes of specified grade & conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading & unloading at both destinations & rolling and lowering into trenches, laying true to line & jointing of pipes & specials with electrofusion welding,giving hydraulic test as per relevant ISS with all lead & lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from excation, testing commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0.Item 9.1.2 Pg -95

390

257

100327.5

... More
code375 - 13.4 Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per directions of engineer in charge of the work and latest amendments 13.9 3.00 HP/2.2KW of 20 STG.Item no-13.9.3 Pg-150

3

23095

69287.4

... More
code376 - Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments.3 HP, size 50x40 Head 30M, Discharge 198 LPM( Common SR 2023-24 Item 13.40.3, Pg No. 157 Vol-05)

4

19756

79027.2

... More
code377 - 13.23 Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete 13.23.1 Upto 3 HP pumps

2

6825

13650

... More
code378 - 2.5 Supplying & drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 & (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volt as per IS-694:1990 2.5.2 3Cx1.5 mm2

600

75

45360

... More
code379 - 13.25 Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets

3

577

1732.5

... More
code380 - 13.26 Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box

3

1207

3622.5

... More
code381 - 13.30 Supply & delivery at site Accessories for Single Phase pumpset like SS Groove Nipples,SS Studs & Nuts,Screw Clips &water proof Insulation Tape etc with ISI mark

3

4725

14175

... More
code382 - 13.31 Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets.

475

42

19950

... More
code383 - 13.32 Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work.

3

6825

20475

... More
code384 - 1.6 Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.

21.06

508

10702.692

... More
code385 - 1.10 Refilling available earth around trenches/pipelines,cables in layers not exceeding 20 cms in depth,compacting each deposited layer by ramming after watering with a lead upto 50 m,& lift upto 1.5 m.including cost of all labour complete as per specfctn

6

168

1008

... More
code386 - Providing fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work). 25mm nominal OD pipes (V-2 I 13.33.3)

18

310

5594.4

... More
code387 - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m (Common SR 2023-24 Item No. 1.14.1, Page No. 8 Vol-01)

1121.09

107

120068.739

... More
code388 - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Depth exceeding 1.5 m, but not exceeding 3 m for ordinary/soft rock without blasting(Common SR 2023-24 Item No. 1.15.2, Page No. 9 Vol-01)

320

446

142800

... More
code389 - 1.23 Providing & Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering,including cost of all materials and labour with all lead & lift complete as per specifications.( SR Vol-1 Item no-1.23 Pg 11 )

43.33

2816

122021.613

... More
code390 - Providing and laying in position CC for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates (SR 23-24 Item 2.1.3, Page.15 Vol-01)

110.33

6288

693804.6885

... More
code391 - Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.(common SR Vol-1 Item no-1.11 Page 7)

61.9

454

28142.835

... More
code392 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (1 cement : 6 coarse sand) (Common SR 23-24 Item 1.9,Page 7 Vol-01)

606.21

279

169314.453

... More
code393 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Common SR 2023-24 Item No. 2.2.1, Page No. 15 Vol-01)

329.67

6601

2176267.0545

... More
code394 - Add 8% for Shuttering

301.3

528

159119.543

... More
code395 - Add 50% Shuttering for Beams

13.6

3300

44889.248

... More
code396 - Add 70% Shuttering for Coloumns

5.11

4620

23613.0545

... More
code397 - Providing laying in position CC for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates & fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators,providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes,labour,Usage charges of machinery,curing & all other appurtenances required to complete the work as per technical specification.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (SR 23-24 Item2.4.2,P-16 Vol-01)

165.13

6639

1096322.8395

... More
code398 - Add 50% for Shuttering

165.13

3319

548162.2454

... More
code399 - Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (Common SR 2023-24 Item No. 6.7, Page No. 13 Vol-02)

198.45

8621

1710946.5975

... More
code400 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Common SR 2023-24 Item No. 2.11a, Page No. 18 Vol-01)

35.616

93929

3345405.5376

... More
code401 - Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer,including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes including cost of materials, labour, usagecharges of machinery complete as per specifications and as per directionsof the Engineer-in-Charge. (Common SR 2023-24 Item 11.16.2,Pg. 82 Vol-02)

2347.9

154

362398.365

... More
code402 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including ost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Common SR 2023-24 Item No. 8.9, Page No. 42 Vol-02)External Plastering

2537.73

404

1025877.3525

... More
code403 - Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (SR 23-24 Item 8.31, P 46 Vol-02)

1865.73

186

348704.937

... More
code404 - Applying priming coat: With ready mixed red oxide zinc chromateprimer of approved brand and manufacture on steel galvanised iron/steel works including preparing the surface after thorougly cleaning oil,grease, dirt and foreign matter, cost of materials, labour complete as perspecifications and as per directions of Engineer-in-charge.

139.1

186

25997.79

... More
code405 - Painting Steel work with Deluxe Multi Surface Paint to give an evenshade. Two coat applied @ 0.90L/10 sqm over an under coat of primerapplied @ 0.80 L/10 sqm of approved brand and manufacture includingpreparing the surface after thorougly cleaning oil, grease, dirt and foreignmatter, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.

139.1

145

20301.645

... More
code406 - Clearing & grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings & trees girth up to 300 mm, removal of stumps of trees cut earlier & disposal of unserviceable materials & stacking of serviceable material to be used or auctioned, including removal & disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer (Common SR 23-24 Item 2.5a,Pg 9 Vol-03)

1735

4

7165.55

... More
code407 - Construction of Subgrade and Earthen Shoulder Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 (Common SR 2023-24 Item No.3.6, Page No. 17 Vol-03)

424.25

517

219613.0125

... More
code408 - Wet Mix Macadam (Plant Mix Method) Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.(Common SR 23-24 Item.4.17 Pg. 26 Vol-03)

520.5

2686

1398557.475

... More
code409 - Dry Lean Cement Concrete Sub-base Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 14:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 140 kg/ m3 , optimum moisture content to be determined during trial length construction, concrete strength not to be less than 7 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing (SR 23-24 Item.6.1,Page. 49 Vol-03)

173.5

5166

896301

... More
code410 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. 2.11 h. All other type of structures (Common SR 2023-24 Item No.2.11h Page No. 18 Vol-01)

8.79

77398

680334.1335

... More
code411 - Pavement Quality Concrete using paver - M40 Grade Construction of M40 Grade un-reinforced, dowel jointed,plain cement concrete pavement over a prepared sub base in recommended proportions, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a slip form paver finisher,spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod,admixtures, curing compound, steel channels, finishing to lines and grades as per drawing OPC @ 420 kg/m3 (Common SR 2023-24 Item No.6.2.1Page No. 49 Vol-03)

347

9514

3301375.35

... More
code412 - Ahuja ACM-96 Single Zone Desktop Paging Microphone 1) Single zone desktop paging microphone with a sturdy, aluminium die-cast top and special high reliability switches with integrated LED indicators. 2) Fitted with a flexible 300mm (12”) gooseneck and a high quality unidirectional dynamic cartridge. Supplied with 6 mtrs. twin core shielded low noise cable with 6.3mm (1/4) phone plug. 3) Frequency Response 50-10,000Hz & Sensitivity2.0mV/Pa

20

3317

66356

... More
code413 - Ahuja AWM-630VG PA VHF Wireless Desktop Microphone 1) Stylish & rugged high band VHF wireless desktop microphone & receiver available in different frequencies. 2) Condenser unidirectional transmitter has a sleek gooseneck with ring LED indicator. 3) Transmitter has a push-type ON/OFF switch. 4) Highly sensitive table-top receiver with a telescopic antenna & noise squelch circuitry. 5) Transmitter also has a male XLR connector & connecting cable so that wired mode can also be used, if required. 6) Transmitter operates with 2x1.5V UM-3 pencil cells. 7) Receiver operates on 9V DC through an AC adaptor, supplied along with.

4

4720

18881.36

... More
code414 - Ahuja SSB-120DP 120-Watts Medium Wattage PA Mixer Amplifier 1) 5 Mic & 2 Aux Inputs. 2) Built-in MP3 player with remote control for USB, SD/MMC card reader. 3) Line output for connecting to a Booster Amplifier and Preamplifier Output for recording the programme. 4) Cut and Boost type Bass & Treble controls. 5) Instant transfer to DC power (Car Battery) if AC power fails. 6) 5 LED array for output level monitoring.

2

4720

9440.68

... More
code415 - Ahuja ABW-400UH PA UHF Wireless Microphone 1) Attractive and versatile high performance single channel UHF wireless microphone available in different frequencies. 2) Bodypack receiver has built-in 6.3mm (1/4) jack plug which provides unbalanced audio output. 3) Volume control knob with RF & POWER LED on the front side of the receiver. 4) One handheld dynamic transmitter, operating on 2x 1.5V AA pencil cells. 5) Receiver has a three position slide switch for ON/STANDBY/OFF position and operates on 2 x 1.5V AA pencil cells. 6) Ideal for: PA Applications... Stage & Auditoriums... Stadia... Seminar Halls... Places of Worship... Recreation Centres.

3

3317

9953.4

... More
code416 - Ahuja SRX-250 DXM 200 Watts PA Speaker System The system combines two 30.48 cm (12”) Full Range Dual Cone speakers and a Piezo Horn Tweeter. It delivers the fidelity of sound and the column effect for sound coverage demanded in sound reinforcement and PA applications. The system is housed in a Rugged Bass Reflex Enclosure made of 18mm board, and Carpet covered.

4

10822

43288.12

... More
code417 - Sony Bravia 139 cm (55 inches) 4K Ultra HD Smart LED Google TV KD-55X74L (Black) 1) Resolution: 4K Ultra HD (3840 x2160) Refresh Rate: 60 Hertz 178 Degree wide viewing angle 2) Connectivity: 3 HDMI ports to connect set top box, Blu Ray players, gaming console 2 USB ports to connect hard drives and other USB devices 3) Sound :20 Watts Output Open Baffle Speaker Dolby Audio Clear Phase eARC Input 4) Smart TV Features: Google TV, Watchlist, Voice Search, Google Play, Chromecast, Netflix, Amazon Prime Video, Additional Features: Apple Airplay, Apple Homekit, Alexa Supported Apps: Netflix, Amazon Prime Video, Disney+ Hotstar, Sony Liv, Zee5, Voot, Jio Cinema & many More 5) Display: X1 4K Processor 4K HDR Live Colour 4K X Reality Pro Motion Flow XR100 6) Warranty Information: 1 year comprehensive warranty on product provided by the brand from the date of purchase

2

84661

169322.04

... More
code418 - Epson EB-X49 XGA Projector Brightness: 3600lm with HDMI Port (Optional Wi-Fi) (V11H982040), White 1)Display: LED 2) Lumen: 1500 Lumen 3) Connectivity and sound: HDMI Connectivity 4)Special Feature: Wireless Display with wifi support 5) Warranty: 1 year warranty from date of purchase.

1

46609

46609.32

... More
code419 - ELCOR Manual Wall Type Series, Projector Screen, 16:09 Aspect Format 65” Height x 116” Width with 133-Inch Diagonal in HD/3D/4K Technology 1) Actual Viewing Area 65” Height x 116” width & 133” Diagonal Size in 16:09 aspect ratio, Ideal for choice for home theater movie, education, conference room presentation, public display, outdoor movie and more. 2) Come in Easy to clean washable fabric material with full black backed side eliminates light penetration for color reproduction, Complimentary 4-side black masking border enhance picture Quality 3) Imported matte white fabric In 1.1 gain with 180 degree viewing angle, Keep your eyes strain with Anti-UV coated material for protect your eyes while viewing movie, compatible for HD/3D/4K content 4) Manual Wall Mount Projection screen with No-Auto-lock / Insta-Lock mechanism, Auto roll back & spring Action option is available In this Model

1

15254

15254.24

... More
code420 - Supplying and placing in position Main Table,ERU & Pedestal of the following specifications of Make GODREJ/FEATHERLITE/ EQUIVALENT. Overall Dimension in MM- 2350x2350x750.(Plus or Minus 5% Variable in sizes is acceptable). a) Primary Work Surface:Made of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping.Soft closing access flap with in build power box are provided on work surface for wire management. b) Secondary Work Surface:Made of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping. c) Modesty Panel:Made of 25mm thick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4mm PVC membrane pressed on to top d) Under- structure:Made of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping. e) Integrated Pedestal:Made of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping. f) Drawer fronts made of 25mm thick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4mm PVC membrane pressed on to top Pedstal. g) Construction is BOX-BOX-FILE type which Uses powder coated 400 MM long metal Panel Drawer Slides. h) Drawer extension is 325 MM.Drawers have a soft closing & anti slam mechanism. Handles are provided for ease of opening. i) Pedestal is provided with lock for security.

1

123049

123049

... More
code421 - Supplying and placing in position Back unit of the following specifications of Make GODREJ/FEATHERLITE/EQUIVALENT.Overall Dimension - 2350x500x1800. a) Top Panel:Made of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping.Slide Door Unit:Made of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping for body panels like side, bottom,back and shelves. b) Shutters are made of 25mm thick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4mm PVC membrane pressed on to top.Shutters have a soft closing & anti slam mechanism. c) Handles are provided for ease of opening. d) Storage is provided with lock for security. e) Display/Storage Unit:Made of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping for body panels like side,back and shelves. f) Doors are made of 25mm thick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4mm PVC membrane pressed on to top. g) Top panel of display unit Made of 25mm thick MDF one side pre-laminate board confirmin to IS-14587:1998 with 0.4mm PVC membrane pressed on to top.

1

92595

92595

... More
code422 - Providing, supplying and placing of High Back Chair of Make GODREJ/FEATHERLITE/ EQUIVALENT. a) SEAT ASSEMBLY: The seat is made up of 1.5Plus or minus0.1 cm thick hot-pressed plywood upholstered with fabric and moulded polyurethane foam.SEAT SIZE: 51.8cm (W) x 49.7cm (D). b) BACK ASSEMBLY: The Back is injection moulded in glass filled Polypropylene which is 2 upholstered with Mesh fabric. The back consist of adjustable Lumbar support made of injection moulded Polypropylene having an adjustment of 5.0 10.1 cm.BACK SIZE: 47.9 cm(W) x 66.9 cm (H). c) HIGH RESILIENCE (HR) POLYURETHANE FOAM: The HR polyurethane seat foam is moulded with density 45+/-2 kg/m and hardness 14 Plus or minus 2 kgf as per IS:7888 for 25% compression. d) ARM RESTS (ADJUSTABLE):The height adjustable armrest is made of Polypropylene and can be adjusted to 6.010.1cm height it also has swivel and To and Fro adjustment with moulded PU armtop. e) ACTIVE BIO-SYNCHRO MECHANISM: The adjustable tilting mechanism is designed with the following features 360degree revolving type Front-pivot for tilt with feet resting on ground & continuous lumber support ensuring more comfort Till tension adjustment can be operated in seating position 5 position Tilt limiter giving option of variable sit angle to the chair Seat/back tilting ratio of 1:2 The mechanism housing is made up of HPDC Aluminium & black powder coated (DFT 40 to 60 micron) f) HEADREST The Headrest sub-assembly is made up of injection moulded glass filed Polypropylene which is upholstered with moulded HR polyurethane loam and fabric has an adjustment of 3.00.1cm & it is assembled over GRETA 20F The complete headrest assembly is retro fic to the main chair. g) PNEUMATIC HEIGHT ADJUSTMENT: The pneumatic height adjustment with an adjustment stroke of 10.0Plus or minus0.3cm. h) PEDESTAL ASSEMBLY: Pedestal is injection moulded in black 30% glass-filled Nylon & fitted with 5 nos. twin wheel castors. The pedestal pitch-center dia is 166.1Plus or minus0.5 cm.(76.1 Plus or minus 1.0 cm. with castors) i) TWIN WHEEL CASTORS: The twin wheel castors are Injection moulded in black Polyamide having 6.01 0.1cm wheel Diameter. j) WIDTH (W) - 76.0cm DEPTH (D) - 76.0cm HEIGHT (H) - 114.0 cm- 123.5cm SEAT Ht - 43.5-54.0cm. k) This product should be certified by Indoor Advantage GOLD, GREENGUARD GOLD, BIFMA LEVEL 2 & GREENPRO

4

15360

61440

... More
code423 - Providing, supplying and placing of 3 Seater Sofa (3+1+1) of Make GODREJ/FEATHERLITE/ EQUIVALENT. a) 3-Seater Dimensions W x H x D (cm) - 179 x 86 x 82.5 b) 1 Seater Dimensions W x H x D (cm) - 87 x 86 x 82.5 c) Finish Color - Burgundy d) Primary Material - Synthetic Leather e) Upholstery Material - Synthetic Leather f) Net Weight (kg) - 37 g) Style - Contemporary & Modern

1

85738

85738

... More
code424 - Providing, supplying and placing of Coffee Table of Make GODREJ/FEATHERLITE/ EQUIVALENT Overall Size : Width : 100cm Depth : 65cm Height : 43cmTABLE MATERIALS: Glass of 08 mm thk tempered, Solid rubber woood legs and frame, MS sheet as bottom shelf .DECORATION MATERIALS & SPECIFICATIONS: (DENSITY / TYPE): PU coating to the rubber wood parts, clear glass Rubber wood understructure with 12 mm tempered glass top. MS sheet at the base, with a laser-cut floral design, can be used as a display shelf.Tapered legs with enhanced aesthetics.

1

27262

27262

... More
code425 - Supplying and placing in position Main Table,ERU & Pedestal of the following specifications of Make GODREJ/FEATHERLITE/EQUIVALENT. Overall Dimension in MM- 2100x2250x750.(Plus or Minus 5% Variable in sizes is acceptable). a) Primary Work Surface:Made of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping.Soft closing access flap with in build power box are provided on work surface for wire management. b) Secondary Work Surface:Made of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping. c) Modesty Panel:Made of 25mm thick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4mm PVC membrane pressed on to top d) Under- structure:Made of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping. e) Integrated Pedestal:Made of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping. f) Drawer fronts made of 25mm thick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4mm PVC membrane pressed on to top Pedstal. g) Construction is BOX-BOX-FILE type which Uses powder coated 400 MM long metal Panel Drawer Slides. h) Drawer extension is 325 MM.Drawers have a soft closing & anti slam mechanism. Handles are provided for ease of opening. i) Pedestal is provided with lock for security.

4

117942

471768

... More
code426 - Supplying and placing in position Back unit of the following specifications of Make GODREJ/FEATHERLITE/EQUIVALENT.Overall Dimension - 1800x500x1800. a) Top Panel:Made of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping.Slide Door Unit:Made of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping for body panels like side, bottom,back and shelves. b) Shutters are made of 25mm thick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4mm PVC membrane pressed on to top.Shutters have a soft closing & anti slam mechanism. c) Handles are provided for ease of opening. d) Storage is provided with lock for security. e) Display/Storage Unit:Made of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping for body panels like side,back and shelves. f) Doors are made of 25mm thick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4mm PVC membrane pressed on to top. g) Top panel of display unit Made of 25mm thick MDF one side pre-laminate board confirmin to IS-14587:1998 with 0.4mm PVC membrane pressed on to top.

4

79033

316132

... More
code427 - Supplying and placing in position Back unit of the following specifications of Make GODREJ/FEATHERLITE/EQUIVALENT.Overall Dimension - 1650x500x750 a) Top Panel:Made of 25mm Thick Pre-laminated twin board of E1- P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping. b) Slide Door Unit:Made of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shad confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping for body panels like side, bottom,back and shelves. c) Shutters are made of 25mm thick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4mm PVC membrane pressed on to top.Shutters have a soft closing & anti slam mechanism. e) Handles are provided for ease of opening. f) Storage is provided with lock for security.

4

51441

205764

... More
code428 - Providing, supplying and placing of Mid Back Chair of Make GODREJ/FEATHERLITE/EQUIVALENT. a) SEAT ASSEMBLY: The seat is made up of 1.5Plus or minus0.1 cm thick hot-pressed plywood upholstered with fabric and moulded polyurethane foam. b) SEAT SIZE: 51.8cm (W) x 49.7cm (D) c) BACK ASSEMBLY: The Back is injection moulded in glass filled Polypropylene which is 2 upholstered with Mesh fabric. The back consist of adjustable Lumbar support made of injection moulded Polypropylene having an adjustment of 5.0 10.1 cm. d) BACK SIZE: 47.9 cm(W) x 66.9 cm (H) e) HIGH RESILIENCE (HR) POLYURETHANE FOAM: The HR polyurethane seat foam is moulded with density 45+/-2 kg/m and hardness 14 Plus or minus 2 kgf as per IS:7888 for 25% compression. f) ARMRESTS (ADJUSTABLE):The height adjustable armrest is made of Polypropylene and can be adjusted to 6.010.1cm height it also has swivel and To and Fro adjustment with moulded PU armtop g) ACTIVE BIO-SYNCHRO MECHANISM: The adjustable tilting mechanism is designed with the following features 360degree revolving type h) Front-pivot for tilt with feet resting on ground & continuous lumber support ensuring more comfort i) Till tension adjustment can be operated in seating position 5 position Tilt limiter giving option of variable sit angle to the chair Seat/back tilting ratio of 1:2 j) The mechanism housing is made up of HPDC Aluminium & black powder coated (DFT 40 to 60 micron) PNEUMATIC HEIGHT ADJUSTMENT: The pneumatic height adjustment with an adjustment stroke of 10.0Plus or minus0.3cm. k) PEDESTAL ASSEMBLY: The pedestal is injection moulded in black 30% glass-filled Nylon fitted with 5 nos. twin wheel castors. The pedestal pitch-center dia is 166.1Plus or minus0.5 cm.(76.1 Plus or minus 1.0 cm. with castors). l) TWIN WHEEL CASTORS: The twin wheel castors are Injection moulded in black Polyamide having 6.01 0.1cm wheel Diameter. WIDTH (W) - 76.0cm DEPTH (D) - 76.0cm m) HEIGHT (H) - 95.5 cm- 105.5cm SEAT HEIGHT - 43.5 - 54.0cm This product should be certified by Indoor Advantage GOLD, GREENGUARD GOLD, BIFMA LEVEL 2 & GREENPRO.

4

14400

57600

... More
code429 - Supplying and Placing in position Main table of the following specifications of Make GODREJ/FEATHERLITE/EQUIVALENT.Its size shall be 1650mm Width x 900mm Depth x 740mm Height .Table top shall be 25 mm thick plain particle board (PPB) Clad with 0.6 mm thick post formed laminate and 1 mm thick backing laminate (bdl) .Flat edge Duly sealed with 2 mm thick PVC beading.The modesty shall be 18 mm thick plain particle board ( ) PPB Clad with 1.0 mm thick decorative laminate (DL) on both sides. Edge Sealed with 2 mm thick PVC beading

38

31486

1196468

... More
code430 - Supplying and placing in position ERU of the following specifications of Make GODREJ/FEATHERLITE/EQUIVALENT.Its size shall be 1550 Width x 450 Depth x 705 Height.The top of ERU shall be 25 mm thick plain particle board (PPB) Clad with 0.6 mm thick post formed laminate and 1 mm thick Backing Laminate ( BDL).Flat Edge duly sealed with 2 mm thick PVC beading. The Modesty shall be 18 mm thick plain particle board (PPB) Clad with 1.0 mm thick Decorative Laminate (DL) on both sides. Edge sealed with 2 mm thick PVC Beading.

26

18210

473460

... More
code431 - Supplying and placing in position Back unit of the following specifications of Make GODREJ/FEATHERLITE/EQUIVALENT with size of 1280 Width x 425 Depth x 705 Height. Top of HDU shall be 25 mm thick plain particle board (PPB) Clad with 0.6 mm thick post formed laminate and 1 mm thick Backing Laminate ( BDL).Flat Edge duly sealed with 2 mm thick PVC beading. The Modesty shall be 18 mm thick plain particle board (PPB) Clad with 1.0 mm thick Decorative Laminate (DL) on both sides. Edge sealed with 2 mm thick PVC Beading.

26

31482

818532

... More
code432 - Providing, supplying and placing of Mid Back Chair of Make GODREJ/FEATHERLITE/ EQUIVALENT.. a) SEAT ASSEMBLY: The seat is made up of 1.5Plus or minus0.1 cm thick hot-pressed plywood upholstered with fabric and moulded polyurethane foam. b) SEAT SIZE: 51.8cm (W) x 49.7cm (D) c) BACK ASSEMBLY: The Back is injection moulded in glass filled Polypropylene which is 2 upholstered with Mesh fabric. The back consist of adjustable Lumbar support made of injection moulded Polypropylene having an adjustment of 5.0 10.1 cm. BACK SIZE: 47.9 cm(W) x 66.9 cm (H) d) HIGH RESILIENCE (HR) POLYURETHANE FOAM: The HR polyurethane seat foam is moulded with density 45+/-2 kg/m and hardness 14 Plus or minus 2 kgf as per IS:7888 for 25% compression. e) ARMRESTS (ADJUSTABLE):The height adjustable armrest is made of Polypropylene and can be adjusted to 6.010.1cm height it also has swivel and To and Fro adjustment with moulded PU armtop f) ACTIVE BIO-SYNCHRO MECHANISM: The adjustable tilting mechanism is designed with the following features 360degree revolving type Front-pivot for tilt with feet resting on ground & continuous lumber support ensuring more comfort Till tension adjustment can be operated in seating position 5 position Tilt limiter giving option of variable sit angle to the chair Seat/back tilting ratio of 1:2 The mechanism housing is made up of HPDC Aluminium & black powder coated (DFT 40 to 60 micron) g) PNEUMATIC HEIGHT ADJUSTMENT: The pneumatic height adjustment with an adjustment stroke of 10.0Plus or minus0.3cm. h) PEDESTAL ASSEMBLY: The pedestal is injection moulded in black 30% glass-filled Nylon and fitted with 5 nos. twin wheel castors. The pedestal pitch-center dia is 166.1Plus or minus0.5 cm.(76.1 Plus or minus 1.0 cm. with castors). i) TWIN WHEEL CASTORS: The twin wheel castors are Injection moulded in black Polyamide having 6.01 0.1cm wheel Diameter. j) WIDTH (W) - 76.0cm DEPTH (D) - 76.0cm HEIGHT (H) - 95.5 cm- 105.5cm SEAT HEIGHT - 43.5 - 54.0cm This product should be certified by Indoor Advantage GOLD, GREENGUARD GOLD, BIFMA LEVEL 2 & GREENPRO

26

14400

374400

... More
code433 - Supplying and placing in position Free Standing Pedestal with castors of the following specifications of Make GODREJ/FEATHERLITE/EQUIVALENT with Overall Dimensions shall be 390mm(W)x440mm(D)x646mm(H). The construction & Material used shall be welded assembled , 0.8 mm thick CRCA for body shell , drawer front & tray , front side stiffener ,rear aide stiffener and 1.2 mm thick CRCA Top stiffener & Bottom stoffener . The drawer fronts shall be metal front straight edge . Locking shall be 10 lever cam lock & Central RH locking with actuator & lock channel mechanism for boxbox-file Pedestal . The top panel shall be metal straight edge top . Castor should be swiveling non - lockable castors mounted below the body shell for free standing full height mobile pedestal and M8 Leveling stud for free standing pedestal . The anti-tipping mechanism shall have fifth roller arrangement mounted below file drawer to avoid toppling of unit when file drawer is pulled out . Partition in drawer shall be 1 no. Partition in box drawers with lock mounted.Plastic pencil tray shall be optional accessory . Finish shall be epoxy polyester powder coated to the thickness of 50 microns . Application shall be suitable for pushing below work surface which has got a clear height of 725 mm from below.For drawer pulling side wise tapered recess provided in shell behind drawer fronts .

26

15046

391196

... More
code434 - Supplying and placing in position Main table of the following specifications of Make GODREJ/FEATHERLITE/EQUIVALENT .Its size shall be 1500 Width mm x 750 Depth mm x 740 Height mm .Table top shall be 25 mm thick plain particle board (PPB) Clad with 0.6 mm thick post formed laminate and 1 mm thick backing laminate (bdl) .Flat edge Duly sealed with 2 mm thick PVC beading.The modesty shall be 18 mm thick plain particle board (PPB) Clad with 1.0 mm thick decorative laminate (DL) on both sides. Edge Sealed with 2 mm thick PVC beading along with supplying and placing in position ERU of the following specifications of Make GODREJ/FEATHERLITE/EQUIVALENT.Its size shall be 1550 Width x 450 Depth x 705 Height.The top of ERU shall be 25 mm thick plain particle board (PPB) Clad with 0.6 mm thick post formed laminate and 1 mm thick Backing Laminate ( BDL).Flat Edge duly sealed with 2 mm thick PVC beading. The Modesty shall be 18 mm thick plain particle board (PPB) Clad with 1.0 mm thick Decorative Laminate (DL) on both sides. Edge sealed with 2 mm thick PVC Beading

51

46370

2364870

... More
code435 - Supplying and placing in position Back unit of the following specifications of Make GODREJ/FEATHERLITE/EQUIVALENT with size of 1280 Width x 425 Depth x 705 Height. Top of HDU shall be 25 mm thick plain particle board (PPB) Clad with 0.6 mm thick post formed laminate and 1 mm thick Backing Laminate ( BDL).Flat Edge duly sealed with 2 mm thick PVC beading. The Modesty shall be 18 mm thick plain particle board (PPB) Clad with 1.0 mm thick Decorative Laminate (DL) on both sides. Edge sealed with 2 mm thick PVC Beading.

49

31482

1542618

... More
code436 - Supplying and placing in position Free Standing Pedestal with Castors of the following specifications of Make GODREJ/FEATHERLITE/EQUIVALENT with Overall Dimensions shall be 390mm(W)x440mm(D)x646mm(H). The construction & Material used shall be welded assembled , 0.8 mm thick CRCA for body shell , drawer front & tray , front side stiffener ,rear aide stiffener and 1.2 mm thick CRCA Top stiffener & Bottom stoffener . The drawer fronts shall be metal front straight edge . Locking shall be 10 lever cam lock & Central RH locking with actuator & lock channel mechanism for box box-file Pedest. The top panel shall be metal straight edge top . Castor should be swiveling non - lockable castors mounted below the body shell for free standing full height mobile pedestal and M8 Leveling stud for free standing pedestal . The anti-tipping mechanism shall have fifth roller arrangement mounted below file drawer to avoid toppling of unit when file drawer is pulled out . Partition in drawer shall be 1 no. Partition in box drawers with lock mounted . Plastic pencil tray shall be optional accessory . Finish shall be epoxy polyester powder coated to the thickness of 50 microns . Application shall be suitable for pushing below work surface which has got a clear height of 725 mm from below . For drawer pulling side wise tapered recess provided in shell behind drawer fronts .

51

15046

767346

... More
code437 - Providing, supplying and placing of Mid Back Chair of Make GODREJ/FEATHERLITE/EQUIVALENT. a) SEAT/BACK ASSEMBLY: The seat is made up of 1.5 Plus or minus0.1cm. thick hot-pressedplywood and upholstered with fabric upholstery covers and moulded Polyurethane foam.The seat has extra thick foam on front edge to give comfort to popliteal area. The Back is injection moulded in glass filled Polypropylene which is upholstered withMesh fabric.The back consist of adjustable lumbar support made of injection mouldedPolypropylene having an adjustment of 5.0 Plus or minus0.1 cm. The chair seat & back size are *SEAT SIZE 53.5 cm. (W) x 51.0 cm. (D)*MESH BACK SIZE 51.0 cm. (W) x 70.0 cm. (H) HIGH RESILIENCE (HR) b) POLYURETHANE FOAM: The HR polyurethane seat foam is moulded with density 45Plus or minus2 kg/cum and hardness 16Plus or minus2 kgf as per IS:7888 for 25% compression. ARMRESTS :The adjustable armrest is designed with the following features : Up-Down adjustment- 6 steps (7.2 Plus or minus 0.5cm range) Armrest top is mounted on Armrest structure made of glass filled Nylon Armrest Top is PU moulded over glass filled Nylon insert. c) CENTER TILT SYNCHRO MECHANISM WITH MULTI LOCK : The mechanism isdesigned with the following features: 360degree revolving type. 3 position locking with anti shock mechanism. Tilt tension adjustment PNEUMATIC HEIGHT ADJUSTMENT: The pneumatic height adjustment with anadjustment stroke of 9.5 Plus or minus 0.3cm. d) PEDESTAL ASSEMBLY : The pedestal is injection moulded in glass-filled Nylon andfitted with 5 nos. twin wheel castors. The pedestal is 66.1 Plus or minus0.5cm. pitch-center dia.(76.1 Plus or minus1.0cm with castors). e) TWIN WHEEL CASTORS : The twin wheel castors are injection moulded in Black Nylon. f) WIDTH (W): 76.1 CM. DEPTH (D): 76.1 CM. HEIGHT (H): 101.5 - 111.0 CM. SEAT HEIGHT (SH): 44.5 - 54.0 CM. This product should be certified by Indoor Advantage GOLD, GREENGUARD GOLD, BIFMA Level 2 & GREEN PRO

81

11040

894240

... More
code438 - Providing & placing in position office table without CPU hanger of Make GODREJ/FEATHERLITE/EQUIVALENT. with overall size shall be 1200 Width mm x 600 Depth mm x 728 Height mm. Top shall be 18 mm thick Pre laminated particle board all work surface edges shall be having duly sealed with 2 mm thick PVC edgebanding. Understructure Modesty Panel 18 mm thick Pre laminated particle board . The Rectangular frame shall be fabricated component in 1.2 mm thick CRCA , Finish : powder Coat( epoxy polyster) . Leg shall be fabricated component in 38 mm x 25 mm 1.2 mm thick MS ERW ATube ,finish powder coat ( epoxy polyster).The plastic cap for cable travel shall be injection moulded polypropylene and leveler glide for shall be nylon 6 & MS bolt. The storage shall be having shell and drawer tray 0.6 mm thick CRCA Finish powder coat (epoxy polyster) plus the drawer front shall be 0.8 mm thick CRCA Finish powder coat (epoxy polyster) plus lock with 10 lever and handle and leveller. The wire management shall be horizontal wire carrier 0.7 mm thick CRCA Finish powder coat (epoxy polyster) and vertical wire carrier 0.8 mm thick CRCA Finish powder coat (epoxy polyster) .

15

23265

348975

... More
code439 - Supplying and placing in position conference table of the following specifications of Make GODREJ/FEATHERLITE/EQUIVALENT.with following size shall be i) 2 STR MAIN - 1350 x 710 x 740 ii) 2 STR SHARED - 1350 x 710 x 740 iii) 2 STR END LH - 1350 x 710 x 740 iv)2 STR END RH - 1350 x 710 x 740 2350W - 2350 x 850 x 740 Work Surface-Made of 36mm thick MDFone side prelaminate board conforming to IS14587:1998 with 0.4mm PVC membrane pressed on to top and having chamfered edge. Full length access panel is provided with soft closing hinges inline with worktop edge. Worktop is available in various shapes. Understructure-The understructure consist of mixture of 18mm and 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade conforming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping. Aluminium alloy 63400 - WP profile is used for connecting panels together. Modesty-Made of 18mm Thick Pre-laminated twin board of E1-P2 grade and approved shade conforming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping. Wire Management-An array of panels made of 0.8mm and 1.2 mm CRCA MS IS:513, epoxy polyester powder coated (DFT 40-60 microns) is used for flow of wires and cables. Cutout for Standard Anchor Roma 4 module is provided for electrical fittings in Straight two seater and single seater modules below access flap per seat. AV Details-The table is equipped with Extron cables cubbies along with cable retractors as standard offering only for 1800mm head module, 2350mm head module, 150degree head module and 165degree head module. For straight two seater and single seater modules, provision to mount AV cables is provided (eg. HDMI,VGAA, etc). Only Corner 90degree, 30degree corner and 50degree corner modules have provision for wire flow between adjacent tables. Additional Wirecover made of 0.8mm Thick CRCA, provided below worktop to conceal MicroAV Detailsphone wires running from table top to wire tray. For Meeting Hall)

1

635144

635144

... More
code440 - Providing, supplying and placing of waiting chair of 3-seater with 2 arms of Make GODREJ/FEATHERLITE/ EQUIVALENT .SEAT/BACK SHELL: It is powder-coated shell made from cold rolled M.S. sheet 0.12 Plus or minus 0.013 cm thickness with circular perforations.The Side Bar is made of cold rolled M.S.sheet 0.12 Plus or minus 0.013 cm thickness. The Shell is assembled on the Cross Beam with help of M8 Bolts. SEAT SIZE : 50.0 cm (W) x 45.5 cm (D) BACK SIZE : 50.0 cm (W) x 56.0 cm (H) CROSS BEAM: It is made up of cold rolled steel with 0.2 Plus or minus 0.02 cm thickness. The crossbeam is powder coated. It is covered with plastic end caps LEG: It is made up of cold rolled steel with 0.12 Plus or minus 0.013 cm thickness. It is powder coated. The legs are fitted with leveller cups covered with SS304 sheet. ARMREST: It is made of SS304 round tube of Phi 3.175 Plus or minus 0.03cm x 0.12 Plus or minus 0.013 cm thick formed to make an oblong shape. WIDTH (W): 173.5 CM. DEPTH (D): 74.0 CM. HEIGHT (H): 91.0 CM SEAT HEIGHT (SH): 44.0 CM. This product should be certified by GREENGUARD GOLD.

35

34200

1197000

... More
code441 - Providing, supplying and placing of Visitor Chair of Make GODREJ/FEATHERLITE/EQUIVALENT. SEAT/BACK ASSEMBLY: The seat and back are made up of 1.2 Plus or minus0.1cm. thick hot-pressedplywood measured upholstered with fabric upholstery covers and moulded Polyurethane foam. The back foam is designed with contouredlumbar support for extra comfort. The seat has extra thick foam on front edge to give comfort topopliteal area. MID BACK SIZE 47.5 cm. (W) x 58.0 cm. (H). SEAT SIZE 47.0 cm. (W) x 48.0 cm. (D) HIGH RESILIENCE (HR) POLYURETHANE FOAM: The HR polyurethane foam is moulded withdensity = 45Plus or minus2 kg/m3 and hardness load 16 Plus or minus 2 kgf as per IS:7888 for 25% compression. ARMRESTS :The one-piece armrests are injection moulded from black Co-polymer Polypropylene. TUBULAR FRAME : The powder coated ( DFT 40-60 microns ) tubular frame iscantilever type & made of Phi 2.54 Plus or minus0.03cm. x 0.2 Plus or minus0.016cm.thk. M.S. ER.W. Tube. Overall Dimensions of Chair WIDTH (W): 61.4 CM. DEPTH (D): 64.5 CM. HEIGHT (H): 89.5 CM. SEAT HEIGHT (SH): 46.5 CM. This product should be certified by Indoor Advantage GOLD & GREEN PRO.

301

8845

2662345

... More
code442 - Providing, supplying and placing of Computer Table of Make GODREJ/FEATHERLITE/EQUIVALENT. Table Top: 35 Kg. Shelf:15 Kg. Drawer: 5.0 Kg. Overall Size (Width X Depth X Height): (+/-2) mm Length: 1200 mmWidth:600 mm Height: 750 mm Number of Cartons:1 Carton Specs:5 ply, 150 gsm, 16 BS. Carton Size (each Carton): L x W x H ( Carton 1 of 1) 1240 mm x 710 mm x 80 mm Raw Material (specs of laminations & thickness): Pre-laminated particle board 18 mm [NOVOPAN BOARDS] Metal Parts: (Material & Coating details) SLIDE MOUNTING DRAWER SLIDE [BLACK POWDER COATING] Hardware: (Details) MINIFIX SET,CASTOR ,FASTNERS,WIRE MANAGER,UNIVERSAL LOCK Construction: Knock down fitting.

33

12948

427284

... More
code443 - RECTA WORKSTATIONS - 1200 x 600 Providing and placing "UPBEAT"desk based modular workstation with System ht - 1200mm. PARTIAL SCREENS: Fabric T- mould, 19mm thk Screen of 450mm ht.,mounted on studs LEGS: Providing metal powder coated Dfine Plus leg. Legs are for standard workstation height of 750mm. UNDERSTRUCTURE: Comprising of metal powder coated cross connectors between legs and legs. Made up of metal powder coated finish and the entire assemply is fixed to the worktop. WIRE MANAGEMENT: For 750 high workstations- For vertical wiremenagement,Shared legs / wire risers with cover are considere. For horizontal wiremanagement - Wire Tray with integrated power box.Access flap will be provided. Switch plate of (8+3Anchor Roma) module is considered for Power and Data points. WORKSURFACE - Out of 25 mm thk prelam particle board with flat pvc lipping edge banding of size 1200 mm w x 600 mm d.Extended worktop unit is provided at the termination and it will have a back to back worktop with added length of 600 mm over the regular workstation length. MODESTY : Wooden modesty: Wooden modesty is made from 18 mm thick PLT with 2 mm PVC lipping on all edges.Metal modesty: Lazer cut perforated Metal modesty Metal and wooden modesty are mounted on the worktop with the help of the modesty mounting brackets Modesty terminates at 400 mm from ground. a.Pedestals with or without legs - Nova pedestal flat metal front, full ht free standing central locking of size 390 mm w x 435 mm d x 646 mm ht 3dr = 2box+1file. b.CPU trolley - with castors c.KBPT with/without mousetray - Metal

71

27927

1982859.6

... More
code444 - Providing Steel Almirah of Godrej or any other Equivalent make of size 198.1Cm X 91.6CM X48.6CM having with four adjustable shelves with a 3-way bolting device and a six lever lock for maximum securitySpecified with GRIHA and GREEN GUARD

54

29000

1566000

... More
code445 - Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material & disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.in cement mortar (Sl 19.9.2,Pg187 , Vol II )

606.84

1768

1073014.488

... More
code446 - Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. In cement mortar.(Sl 19.7.3,Pg 187,Vol II )

45.89

1080

49581.8505

... More
code447 - Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.(Sl 19.3, Pg-187,Vol II )

26.04

2547

66331.692

... More
code448 - Dismantling aluminium/ Gypsum partitions, doors,windows, fixed glazing,false ceiling including disposal of unserviceable material and stackingof serviceable material to the appropriate disposal area as per direction of Engineer-in-charge.(Sl 19.56,Pg-193,Vol II )

36

37

1360.8

... More
code449 - Dismantling chain link fencing including removing the posts, cement concrete fedestals, foundation and stacking the useful materials safely at a distance to the appropriate disposal area as per direction of Engineerin- charge.(Sl 19.60,Pg-193,Vol II )

1100

23

25410

... More
code450 - Demolishing dry brick pitching in floors, drains etc. including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. (Sl 19.23, Pg-189,Vol II )

26.7375

945

25266.9375

... More
code451 - Disposal of unserviceable buidling materials for Loading, unloading and transportation charges upto 15.00 KM radius.

705.5

50

35275

... More
code452 - Stones Considered 25% of Total Qty (i.e 606.84 X 25%=151.71 cum. Considering the size of the block i.e 0.2mt X 0.2mt X 0.25mt. Hence no of stones=151.71 cum/(0.2*0.2*0.25) and Considering Rs 15.00 as market rate per stone Consider 25% of Stone dismantle dQty i.e 606.84*25/100

15170.94

15

227564.1

... More
code453 - Steel @ 75kg/cum (incl. 18% GST) Released RCC roof slab reinforcements in ton, approx considered steel in kg per cum is 75kg i.e[26.04X75=1953 kg or 1.95 Tonne] Consider 75gg/cum of RCC Qty i.e 26.04*75

1952.66

40

78106.4

... More
code454 - Clearing & grubbing road land including uprooting rank vegetation, grass, bushes, shrubs,saplings & trees girth up to 300 mm, removal of stumps of trees cut earlier & disposal of unserviceable materials & stacking of serviceable material to be used or auctioned, including removal & disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer (Common SR 23-24 Item.2.5a,Pg-9 Vol-03)

650

4

2684.5

... More
code455 - Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. (Common SR 23-24 Item 4.1,Page 5 Vol-02)

42.25

123

5234.775

... More
code456 - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m (Common SR 2023-24 Item No. 1.14.1, Page No. 8 Vol-01)

39.54

107

4234.734

... More
code457 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates (Common SR 2023-24 Item No. 2.1.3, Page No. 15 Vol-01)

2.61

6288

16412.8545

... More
code458 - Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (Common SR 23-24 Item 5.4, Page No. 9 Vol-02)

33.21

6708

222787.6245

... More
code459 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (1 cement : 6 coarse sand) (Common SR 2023-24 Item 1.9,Page-7 Vol-01)

179.66

279

50179.038

... More
code460 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Common SR 2023-24 Item No. 2.2.1, Page No. 15 Vol-01)

24.36

6961

169582.14

... More
code461 - Centering/shuttering for Footings 8%

4.86

556

2706.6312

... More
code462 - Centering/shuttering for Columns 70%

3.026

4873

14745.8493

... More
code463 - Centering/shuttering for plinth,sill,Lintel,Beams 50%

6.87

3480

23912.7525

... More
code464 - Centering/shuttering for Roof slab 50%

9.6

3480

33415.2

... More
code465 - Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (Common SR 2023-24 Item No. 6.7, Page No. 13 Vol-02)

16.95

8621

146135.2725

... More
code466 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Common SR 2023-24 Item No. 2.11a, Page No. 18 Vol-01)

2.95

93929

277093.0575

... More
code467 - Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383:2016:, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, primer, sealant, curing of concrete slabs for 14-days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work. (Common SR 23-24 Item 16.28,IRC-1501, P.No. 149 Vol-03)

18.34

7091

130061.778

... More
code468 - Providing & fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding (SR 23-24 Item 11.34A,Pg-86 Vol-02)

151.2

176

26671.68

... More
code469 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Common SR 2023-24 Item No. 8.2.1, Page No. 41 Vol-02)

218.8

309

67773.3

... More
code470 - Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Common SR 2023-24 Item No. 8.10, Page No. 43 Vol-02)

64

221

14179.2

... More
code471 - Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Common SR 2023-24 Item No. 8.27, Page No. 45 Vol-02)

142

55

7902.3

... More
code472 - Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. (Common SR 2023-24 Item No. 8.54.2, Page No. 50 Vol-02)

142

115

16401

... More
code473 - Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Common SR 2023-24 Item No. 8.31, Page No. 46 Vol-02)

218.8

186

40893.72

... More
code474 - Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (Common SR 2023-24 Item No. 12.90, Page No. 110 Vol-02)

7.2

7070

50909.04

... More
code475 - Removing of existing old MS DOOR(TTB BUILDING) & MS gate(STORE YARD) with side brackets which is usable and fixing it to new building with all cost and conveyance labour for all items of work, HOM with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification & directions of the Engineer-in-charge of the work.

2

8000

16000

... More
code476 - Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of E+B367ngineer-in-charge. (Common SR 2023-24 Item No. 8.40, Page No. 48 Vol-02)

30.24

120

3651.48

... More
code477 - Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineerin- charge. (Made of G.I. wire of dia 4 mm).(Common SR 2023-24 Item No.11.58, Pg No. 95 Vol-02)

100

843

84315

... More
code478 - Shifting of transformers from existing store yard to new proposed store yard using Crane with grab 0.75 m3 capacity(Pt no 20, page no:A-43)

56

842

47157.6

... More
code479 - Shifting of oil barrels and store items from existing store yard to new proposed store yard using Tipper -10 m3 (UnsurfacedGravelled Road)(Pt no 113, page no:A-46)

800

8

6992



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.