Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Rural Water Supply And Sanitation Department - RWSS Tender

Opening Date18 Jan 2021
Closing Date29 Jan 2021
Tender Amount₹ 1,60,84,833 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Summary

Providing 102 New Fhtc Households By Augmentation And Retrofitting Of The Existing Scheme Of Chowdlu Habitation In Chowdlu Village At Chowdlu G.p., (ser 72/2020-21-rs.189.97 Lks

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments - Size 65 mm ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

1

-

1355

... More
Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments -Size 65 mm ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

1

-

1395

... More
Supply installing testing and commissioning COMMON CONTROL PANEL consisting of the following INCOMING 1 No. Set of Phase indicating lamps with SFU of suitable 1 No., Analog Ammeter, 1 No Analog Voltmeter 1 No. with Phase - 6 HP to 15 HP pumps ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

1

-

13288

... More
Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

1

-

5650

... More
Labour charges for Erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including providing cement concrete foundation bed etc., complete. as per specifications, with testing of as per instructions of engineer incharge of work ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

1

-

1127

... More
Labour charges for Providing main connection from pole - PVC insulated sheathed steel wire cable as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit, with all necessary materials and labour tools and equipments, as per specifications, with testing of as per instructions of engineer incharge of work ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

30

-

5400

... More
Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collers,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

70

-

34860

... More
(Rising Main) Earthwork excavation for pipeline trenches including depositing on bank upto a lead of 50 mtrs and depth up to 2.00 mtrs. Including shoring and strutting, danger lighting and using sight rails and boning rods at every 100 mtrs. Wherever necessary as directed in the following strata. (Manual Means) In Ordinary Soil ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

1440

-

415008

... More
Earthwork excavation for pipeline trenches including depositing on bank upto a lead of 50 mtrs and depth up to 1.50 mtrs. Including shoring and strutting, danger lighting and using sight rails and boning rods at every 100 mtrs. Wherever necessary as directed (Manual Means) In Ordinary rock without blasting ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

360

-

234432

... More
Supplying HDPE pipes conforming to IS 4984:1995 with latest amendments and conveying to work site including loading and unloading at both destination and rolling, lowering into trenches, laying true to line and jointing of pipes and specials by electrofusion welding, as per standerd procedure and guide lines including encasing the pipe around to a depth not less than 15cms with cleaned soft gravel or selected earth available from the excavation etc., complete giving hydraulic test as per relevant IS Specification with all lead and lift including , testing and commissioning. The rate is exclusive of required specials and fittings etc., complete (Contractor will make his own arrangement for procuring water for testing)Upto 110mm dia,Coils shall be used. PE80 (PN 10.0 / 10 Kg/cm2)-90 mm ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

2500

-

882750

... More
Refilling the basement and pipeline trenches with selected available earth from trench excavation including watering, Consolidation in layers of 15 cm thick including disposing of the surplus earth with all lead & lifts. ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

1575

-

178447.5

... More
Supplying,laying,jointing ,testing and commissioning of G.I. Pipes conforming to IS 1239:1990 with latest amendments, including fixing Collars, Elbows, Tees, bends, Glad Cocks and other Fittings (Excluding Cost of Specials) with Cuts and Threads wherever necessary including conveying the materials to workspot, including testing for water tightness with all lead and lifts etc complete (Contractor shall make his own arrangements for procuring water for testing) Class B (Medium) 150 mm ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

80

-

79992

... More
Supply and delivery of Woltman model with removal mechanism water meters confirming to ISO 4064 part I,II,III class B or IS 779 and IS 2373 with life cycle test certificate from FCRI/ NABL accredited lab. The water meters shall have magnetic drivers or mechanical drivers and shall be versatile for installation in any position. The meters shall be hydrodynamically, hydrostatically balanced. The runner, runner chamber, pointer of the meter shall be as per ISO 4064 class B specification. Dry dial excavated counter housing fully protected against flooding ensuring easy reading in all climates.-50mm ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

3

-

42756

... More
(Constrction of GLSR (50000 ltr) Earthwork excavation by manual means for foundation of buildings, culverts, water supply and sanitary lines and electrical conduits etc, either in pits or in trenches 1.5m and above in width, in ordinary soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. including breaking of clods complete as per specifications. ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

22.06

-

7255.53

... More
Providing and laying in position plain cement concrete of grade M 10 with OPC cement @ 220kgs, with 40mm and down size graded granite metal coarse aggregates @0.892cum and fine aggregtes @ 0.465cum machine mixed, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation including cost of all materials, labour, HOM of machinery, curing complete as per specifications. ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

6.68

-

41251.67

... More
Providing and constructing granite / trap / basalt size stone masonry in foundation cement mortar 1:6, stone hammerd dressed in courses not less than 20 cms high, bond stones at 2 m. apart in each course including cost of materials, labour, curing complete as per specifications. KBS 5.1.13. ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

10.8

-

63546.12

... More
Providing and laying cement concrete using 20 mm and down size granite coarse aggregates and fine aggregates of ready mixed concrete (RMC) M 25 for R.C.C works laid in 15 cms thick layers and well compacted vibrating, curing, for all super structure works, Flash mixers, Floculator, RSF, Raft of Zonal balancing Tanks, Raft of Master Blancing Tank, Raft of IPS/IMP, Side wall and Top Dome for GLSR's, Pure water sump etc.. ., including cost of all materials, labour, HOM of machinery, curing,complete but excluding cost of reinforcement as per specifications with all lead and lifts etc., complete (exclusive of cost of steel and fabrication charges.) ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

48.26

-

303280.32

... More
Providing T.M.T steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid) including for OHT & reservoier, cost of materials, labour, HOM of machinery complete as per specifications. _do_ TMT bars Fe 500 ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

2000

-

155720

... More
Providing and fixing M.S. ladder between landing 45 cms. wide using angle iron of following size and 20 mm M.S. bars at 25cms. centre to centre with necessary supports of same angle iron as directed including hand railing on both sides with 25mm dia G.I. pipes with angle iron props at 2 mtrs, interval and 0.5 mtr, height including fixing in ground with C.C. 1:2:4 and two coats of nonpoisonous anticorrosive bituminous paint with all lead and lift etc., complete. 65x65x8mm angle iron frame. ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

9.7

-

19430.07

... More
Providing and applying composite waterproofing compound as impregnate only on wet surfaces to arrest leaks in surfaces such as roof cealing, internal and external walls, flooring and other surfaces apart from water tanks, sumps, reservoirs, by mixing the composite waterproofing compound with water in ratio of 1:10 to make a workable slurry and pouring it on all cleaned and prepared corners and disturbed area and further mixing in the ration 1:20 and pouring it on the prepared surface by cleaning the surface with etchant chemical from dirt foreign materials etc.,and allowing it to be there upto 3 hours and then cleaning the same using water complete as per spcification so that the surface is got back and ready to use after 4 hours. ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

69

-

43794.3

... More
Providing and fixing 60x60cms M.S. inspection door with necessary M.S. frame made out of M.S. angle 50x50x6mm and M.S. shutters of 31.5mm or B.G.10 thick with hinges on top and locking arrangement, painting etc., complete (for RCC over head tank and G.L.S.R.) ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

1

-

1999.8

... More
Labour charges for making, fixing and testing of flanged joints for Cast Iron pipes / D.I. Pipes and specials with rubber insertion and necessary bolts and nuts and giving necessary hydraulic pressure test including conveying, loading and unloading the jointing materials etc., complete. a 80mm (64.00) ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

2

-

173.8

... More
Materials Providing 80 mm dia Sluice valve/ scour valve confirming to IS 1538 (Part-I to XXII) 1978 with latest amendments if any cost of all materials, labour charges etc. complete ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

2

-

5800

... More
Materials Providing 80 mm dia Heavy class 90” double flanged bend confirming to IS 1538 (PartI to XXII) 1978 with latest amendments if any cost of all materials, labour charges etc. complete. ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

4

-

2200

... More
Materials Providing 80 mm dia CI bank flange confirming to IS 1538 (Part-I to XXII) 1978 with latest amendments if any cost of all materials, labour charges etc. complete. ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

3

-

600

... More
Materials Providing 80 mm dia Heavy class 45” double flanged bend confirming to IS 1538 (PartI to XXII) 1978 with latest amendments if any cost of all materials, labour charges etc. complete. ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

3

-

1725

... More
(Construction of Jackwell) Sinking Circular Wells as per approved design in all kinds of soils excluding hard rock requiring blasting including making and removing islands, ring bunds or coffer dams as may be necessary and maintaining the same during operation, pumping dewatering, application of kentledge or other means for around seating of wells, removal of boulders, burried timbers as directed with necessary shoring and strutting as per specifications etc. complete.-3 Mtr inner dia well 0 to 3 Mtr depth ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

3

-

54360.9

... More
Sinking Circular Wells as per approved design in all kinds of soils excluding hard rock requiring blasting including making and removing islands, ring bunds or coffer dams as may be necessary and maintaining the same during operation, pumping dewatering, application of kentledge or other means for around seating of wells, removal of boulders, burried timbers as directed with necessary shoring and strutting as per specifications etc. complete.-3 Mtr. Inner Dia Well from 3 Mtr to 6 Mtr. Depth ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

3

-

60980.7

... More
Sinking Circular Wells as per approved design in all kinds of soils excluding hard rock requiring blasting including making and removing islands, ring bunds or coffer dams as may be necessary and maintaining the same during operation, pumping dewatering, application of kentledge or other means for around seating of wells, removal of boulders, burried timbers as directed with necessary shoring and strutting as per specifications etc. complete.-3 Mtr. Inner Dia Well from 6 Mtr to 9 Mtr. Depth ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

3

-

69950.1

... More
Providing and laying in position plain cement concrete of grade M 10 with OPC cement @ 220kgs, with 40mm and down size graded granite metal coarse aggregates @0.892cum and fine aggregtes @ 0.465cum machine mixed, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation including cost of all materials, labour, HOM of machinery, curing complete as per specifications. ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

3.85

-

23775.29

... More
Providing and laying in position plain cement concrete of grade M 15 with cement @ 240kgs, with 20mm and down size graded granite metal coarse aggregates @0.878cum and fine aggregtes @ 0.53cum, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation,plinth and cills, ncluding cost of all materials, labour, HOM of machinery, curing complete as per specifications. ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

3.85

-

24986.5

... More
Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregtes @ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated forall works in ground floor level for roof slabs, staircase, lintels, and beams,retaining walls, return walls, walls ( any thickness ) including attached pilasters, columns, pillars,posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks,plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing,complete but excluding cost of reinforcement as per specifications. ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

48.8

-

336680.96

... More
Providing T.M.T steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid) including for OHT & reservoier, cost of materials, labour, HOM of machinery complete as per specifications. Fe 500 ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

3.3

-

256938.66

... More
Supply of AC cowl as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimension of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendmens including cost of material and labour charges for fixing, if any etc., complete with all lead and lifts and as directed by the Engineer in charge ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

2

-

385

... More
Providing and fixing 60x60cms M.S. inspection door with necessary M.S. frame made out of M.S. angle 50x50x6mm and M.S. shutters of 31.5mm or B.G.10 thick with hinges on top and locking arrangement, painting etc., complete (for RCC over head tank and G.L.S.R.) ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

1

-

1999.8

... More
Providing & fixing G.I. pipe railing of 32mm dia.,G.I. pipe B-class in two rows of roof dome flat slab of landing of elevated storage reservoir including cutting, welding, threading, painting, embedding in C.M. pillars with all lead and lifts etc., complete. ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

50

-

37345

... More
Providing anodized aluminium ladder using 65mm x 32mm x 3.0mm ‘C’ section for ladder side channel x 25mm dia., flutal pipe for Rungs at 250mm c/c ladder fixed at an angle of 70 degrees to horizontal including necessary 25mm dia., G.I. shutters with necessary G.I. fasteners for bracing the ladders to the Tank walls to prevent buckling of the ladder with necessary (M-15) bed for embedding the ladder bottom complete ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

20

-

68178

... More
KSRRB M2200- Providing Weep Holes KSRRB M2200-8. Providing weep holes in Brick masonry I Plain I Reinforced concrete abutment, wing wall I return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing force. Complete as per drawing and Technical Specifications including cost of materials, labour, HOM complete as per specifications. MORTH Specification No.2706 & 2200 ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

20

-

3234

... More
Supply and delivery of galvanized mild steel tubes heavy class (C Class) as per IS 1239 (Part-I) 1990 with latest amendments with ISI Mark (one end fitted with Heavy Duty collar and other end fitted with protective cover) -50mm dia ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

25

-

17160

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts including pointing ends, and fixing collars with cement mortar 1:2 including cost of all materials, labour, curing complete as per specifications. Specifications. No. KSRB 1000, 2300 MOST Specification No.1000 / 2300 - - 450mm. dia ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

15

-

45655.5

... More
(Construction of Intekwel) Earthwork excavation in soil, clay, sand, shedu soil, soft murrum, including shoring, strutting, barricading, danger lighting, bailing out water wherever necessary with stacking the materials as directed upto a lead of 50 Mtr and lift of 1.5 Mtr etc., complete. 0.00 to 1.50 m ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

4.25

-

1617.55

... More
Earthwork excavation in soil, clay, sand, shedu soil, soft murrum, including shoring, strutting, barricading, danger lighting, bailing out water wherever necessary with stacking the materials as directed upto a lead of 50 Mtr and lift of 1.5 Mtr etc., complete. 1.50 to 3.00 m ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

4.25

-

1884.02

... More
Earthwork excavation in soft rock including shoring, strutting, barricading, danger lighting, bailing out water wherever necessary with stacking the materials as directed upto a lead of 50 Mtr and lift of 1.5 Mtr etc., complete-3.00 to 4.50 m ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

4.25

-

4389.83

... More
Earthwork excavation in soft rock including shoring, strutting, barricading, danger lighting, bailing out water wherever necessary with stacking the materials as directed upto a lead of 50 Mtr and lift of 1.5 Mtr etc., complete-4.50 to 6.00 m ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

4.25

-

4997.58

... More
Providing and laying in position plain cement concrete of grade M 10 with cement @ 220kgs, with 40mm and down size graded granite metal coarse aggregates @0.892cum and fine aggregtes @ 0.465cum machine mixed, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, including cost of all materials, labour, HOM of machinery, curing,lowering to any depth, dewatering etc., complete as per specifications with all lead and lifts for Foundation of steining ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

0.18

-

1277.3

... More
Supplying & errection of RCC rings for well steining of 0.3 Mtr Depth using M-20 grade concrete using clean graded granite or trap or jelly of approved quality 20mm and down size well compacted including centering, formwork and plastering for both faces with C.M 1:3 proportion as per design using 6.50mm M.S. coil at the rate of 10 Kgs/ring including cost of steel and fabrication, bailing out of water, errection etc., complete.-For 1.80m dia (clear) rings of steining thickness 0.075mm upto 18 M depth ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

20

-

34340

... More
Providing and filling with boulders or rubble of approved size and quality, including hand packing, wedging, filling in voids with quarry spalls and clean sand etc., complete with all lead and lifts, etc., complete ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

1.87

-

4050.23

... More
(Construction of Check Dam) Excavation in all kinds of soil by manual means including boulders upto 0.60 m diameter (0.113 cum) for foundation of canal cross drainage and other appurttenant structure and placing the excavated soil neatly in dump area or disposing off the same as directed etc. complete with initial lead upto 50m and initiual lift up to 1.5m ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

51.03

-

13808.72

... More
Providing and laying insitu vibrated M-15 ( 28 days cube compressive strength not less than 15 N / sq mm ) grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates for foundation filling including cost of all materials,machinery, labour, form work, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete with all lead and lifts.( Cement content : 240 kg / cum with use of super plasticiser ) ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

14.36

-

85614.32

... More
Providing and laying insitu vibrated M-20 ( 28 days cube compressive strength not less than 20 N / sq mm ) grade cement concrete using 20 mm down size approved, clean, hard, graded aggregates for RCC through resting on ground including cost of all materials,machinery, labour, form work, centering, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete with all lead and lifts.( Cement content : 330 kg / cum with use of super plasticiser ) ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

55.12

-

463956.06

... More
Providing, fabricating and placing in position rienforcement steel bars for RCC works including clening, straightning, cutting, bending, lapping, welding werever required, tying with 1.25mm dia, soft annealed steel wire, including cost of all materials,machinery, labour etc., complete with lead and lifts. ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

1653.6

-

121870.32

... More
Providing and cunstructing 300mm thick rubble stone pitching setin CM 1:5 propotion with pin headers at 2per sqmm including cost of all materials, labour, packing chips and mortar, finishing etc., complete with all lead and lifts. ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

135

-

82566

... More
(Distribution Network) Earthwork excavation for pipeline trenches including depositing on bank upto a lead of 50 mtrs and depth up to 2.00 mtrs. Including shoring and strutting, danger lighting and using sight rails and boning rods at every 100 mtrs. Wherever necessary as directed in the following strata. (Manual Means) In Ordinary Soil ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

737.74

-

212616.67

... More
Earthwork excavation for pipeline trenches including depositing on bank upto a lead of 50 mtrs and depth up to 2.00 mtrs. Including shoring and strutting, danger lighting and using sight rails and boning rods at every 100 mtrs. Wherever necessary as directed in the following strata. (Manual Means) In Hard Soil ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

258.21

-

74416.12

... More
Earthwork excavation for pipeline trenches including depositing on bank upto a lead of 50 mtrs and depth up to 1.50 mtrs. Including shoring and strutting, danger lighting and using sight rails and boning rods at every 100 mtrs. Wherever necessary as directed (Manual Means) In Ordinary rock without blasting ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

546.47

-

355861.26

... More
Earth work excavatoin for water Supply & Sanitary lines, Electrical conduits either in pits or pipe line trenches (upto 600mm Trench width) as per drawing and technical specification, including setting out, construction of shoring, strutting, barricading, danger lighting, bracing, using sight rails & boning rods at every 100 mm whevere necessary removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench, including backfilling the excavated earth to the extent required and utilising the remaining available excavated earth locally for the work. in the following strata classifications by Mechanical Means Ordinary / Hard Soil - (Depth upto 3m) ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

546.47

-

78145.21

... More
Cutting of road surface for pipeline trenches and disposing of the excavated stuff as directed including barricading, danger lighting etc. in the following classification. - Cutting in Cement Concrete Road Surface ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

19.89

-

24198.17

... More
Cutting of road surface for pipeline trenches and disposing of the excavated stuff as directed including barricading, danger lighting etc. in the following classification. - Cutting Asphalt Road Surface ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

47.73

-

28456.63

... More
Cutting of road surface for pipeline trenches and disposing of the excavated stuff as directed including barricading, danger lighting etc. in the following classification. Cutting Macadam Road Surface ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

63.64

-

24221.38

... More
Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. PVC PIPES OF 6 Kg./Cm2-63mm ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

4100

-

554730

... More
Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. PVC PIPES OF 6 Kg./Cm2-75mm ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

1203

-

202464.9

... More
Supply and delivery of Resilient seated soft sealing Sluice Valves with body, bonnet of Ductile iron of grade GGG50, wedge fully rubber lined with EPDM and seals of NBR and the valves should be of vacuum tight and 100% leak prrof with face dmensions as per BS 5163-89/IS 14846-2000/DIN 3202 F4-F5. The stem sealing sould be with toroidal sealing rings (Minium 2 'O' rings). all the valves should be with electro static powder coating both inside and outside with pocket less body passage. The valve shal be supplied with suitable size galvanized bolts and nuts of required nos as per relevent IS.-50 mm dia ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

4

-

25564

... More
Supplying and fixing of fixed hight surface box H-4057 MD-KU with PP 40% GF lid, Housing of PA+, Locking clip of PP with notched bolt M x 130 hexagon head A2-70 for service connection valves, design deried fron DIN 4057, should be supplied with support tile I (FSL, FSS, SI) should be able to recieve class AA trafic loads ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

4

-

10940

... More
Supplying,laying,jointing ,testing and commissioning of G.I. Pipes conforming to IS 1239:1990 with latest amendments, including fixing Collars, Elbows, Tees, bends, Glad Cocks and other Fittings (Excluding Cost of Specials) with Cuts and Threads wherever necessary including conveying the materials to workspot, including testing for water tightness with all lead and lifts etc complete (Contractor shall make his own arrangements for procuring water for testing) :Class-B (MEDIUM) 80mm ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

530.3

-

344164.7

... More
Refilling the basement and pipeline trenches with selected available earth from trench excavation including watering, Consolidation in layers of 15 cm thick including disposing of the surplus earth with all lead & lifts. ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

3168.76

-

359020.51

... More
Giving hydraulic test for C.I. / R.C.C. / P.V.C. / H.D.P.E/ D.I /A.C. pipelines to the pressure equal to two times the working pressure including cost of supply of water. upto 80mm ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

5303

-

26833.18

... More
(RCC Valve Chamber 04 nos) Earthwork excavation by manual means for foundation of buildings, culverts, water supply and sanitary lines and electrical conduits etc, either in pits or in trenches 1.5m and above in width, in ordinary soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. including breaking of clods complete as per specifications. a) In ordinary soil ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

12.16

-

3999.42

... More
Providing and laying in position plain cement concrete of grade M 10 with OPC cement @ 220kgs, with 40mm and down size graded granite metal coarse aggregates @0.892cum and fine aggregtes @ 0.465cum machine mixed, machine mixed, con ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

0.92

-

5681.37

... More
Providing and laying in position reinforced cement concrete of Design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregtes @ 0.460 cum, with super plasticiser ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

5.48

-

36403.09

... More
Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for foundations, footings, bases of columns for mass concrete including cost of all materials, labour complete as per specificaitons. ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

11.2

-

3240.16

... More
Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for vertical surface such as walls at any thickness, including attached pilasters, buttresses, plinth and string courses cost of all materials, labour complet ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

38.64

-

15343.94

... More
Providing T.M.T steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining - _do_ TMT bars Fe 500 ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

411

-

32000.46

... More
(Functinal Household Tap Connection (FHTC)) Cutting of road surface for pipeline trenches and disposing of the excavated stuff as directed including barricading, danger lighting etc. in the following classification. - Cutting in Cement Concrete Road Surface ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

5.2

-

6326.32

... More
Cutting of road surface for pipeline trenches and disposing of the excavated stuff as directed including barricading, danger lighting etc. in the following classification. - Cutting Asphalt Road Surface ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

2.36

-

1407.03

... More
Cutting of road surface for pipeline trenches and disposing of the excavated stuff as directed including barricading, danger lighting etc. in the following classification. Cutting Macadam Road Surface ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

1.24

-

471.94

... More
Earthwork excavation for pipeline trenches including depositing on bank upto a lead of 50 mtrs and depth up to 2.00 mtrs. Including shoring and strutting, danger lighting and using sight rails and boning rods at every 100 mtrs. Wherever necessary as directed in the following strata. (Manual Means) ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

77.06

-

22208.69

... More
Supply and delivery at site special moulded variety 63 mm dia PVC service saddles as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

52

-

5148

... More
Supply and delivery at site special moulded variety 75 mm dia PVC service saddles as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

32

-

4224

... More
Supply and delivery at site special moulded variety 90 mm dia PVC service saddles as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

22

-

3872

... More
Providing wrought mild steel (galvanized) 15 mm dia GI collar confirming to IS 1239-II, 1991 with latest amendments if any. ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

106

-

4430.8

... More
KSRB13-8.1 : Providing and fixing to wall, ceiling and floor, low density polyethylene pipes 6.00 kgf/sq.cm working pressure 20mm outside diameter with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. Specification No.KBS 13.2.15.1 / 13.9 ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

1187.2

-

139733.44

... More
Supply and delivery at site wrought middle steel (galvanized) 15 mm dia GI elbow confirming to IS 1239-II, 1991 with latest amendments if any. ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

318

-

12084

... More
Supply and delivery at site wrought middle steel (galvanized) 15 mm dia GI union confirming to IS 1239-II, 1991 with latest amendments if any. ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

318

-

17490

... More
Supplying,laying,jointing ,testing and commissioning of G.I. Pipes conforming to IS 1239:1990 with latest amendments, including fixing Collars, Elbows, Tees, bends, Glad Cocks and other Fittings (Excluding Cost of Specials) with Cuts and Threads wherever necessary including conveying the materials to workspot, including testing for water tightness with all lead and lifts etc complete (Contractor shall make his own arrangements for procuring water for testing) :Class-B (MEDIUM) - 32mm ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

159

-

49146.9

... More
Providing and fixing flow control valve using food grade material SS 316 ball/ 1/2" (15mm) including cost of materials, labour charges, HOM and testing complete as per specification The FCV nominal design if for 5ltr/Min Discharges at 0.5 bar MOC of valve -food grade stainless steel SS-316 Flow direction arrow embossed on its outside surface The valve should act as flow control vaive and non-return valve Minimum operating pressure Kgf ( cm head) Desined presure : 1 meter to 50 meters Accuracy of vaives : +20% of avarage flow rate Orifice size : not be less than 12mm Ball size : not less than mm Weight of FCV : not less than gms The FCV is with internal arrangements of very simple passage in line The FCV shall be got tested from FCRI by the manufacturer as per The FCV should be fitted on Saddle, which is fixed on distribution ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

106

-

27030

... More
KSRB13-5 : Providing and fixing water meter with stop cock, jam nut, socket in G.I pipe line including cutting and threading the pipe and making long screws including cost of all materials, labour, HOM of equipments and testing complete as per specifications. Specification No.KBS 13.2.19 / 13.16 ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

1335

-

1938420

... More
Supply and fixing of HDPE water meter box to protect the water meter of class 'B: multijet type of size 15 to 32mm including HDPE box with base dia 300mmxlid dia 200mmxheight 250mm with openable lid and the cover is buried below GL with lid flush with GL including earthwork excavation for 600mmx600mm and base sand filling for 100mm thick over which the cover is placed and enclosed by PCC 1:2:4 using 12 to 20mm BG jelly for an height of 150mm and refilling with excavated earth for balance 100mm height,disposal of excess earth with all lead and lifts etc complete as per drawing enclosed ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

1335

-

734250

... More
Refilling the basement and pipeline trenches with selected available earth from trench excavation including watering, Consolidation in layers of 15 cm thick including disposing of the surplus earth with all lead & lifts. (Compacting with vibro roller) Note: Add Rs. 203.00 / cum for earth obtained from borrow pits. ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

1073.03

-

121574.3

... More
Providing and laying in position plain cement concrete of mix M20 with OPC cement @ 300kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregtes @ 0.43cum, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation,plinth and cills, including cost of all materials, labour, HOM of machinery, curing complete as per specifications. ---- WITH LEAD & LIFT COMPLETE AS PER THE DIRECTIONS OF ENGINEER IN CHARGE

8.32

-

52010.82



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.