Directorate Of Municipal Administration Tender
... More
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
Costs
EMD
₹ 64,607Document Cost
Refer DocumentsTender Fee
₹ 960
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
DMA/2024-25/BD/WORK_INDENT32449Tender No
DMA/2024-25/BD/WORK_INDENT32449Tender Authority
Directorate Of Municipal Administration ViewPurchaser Address
-Website
http://bidplus.gem.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
4.1 - Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.
256.7
123
31805.13
... More
1.9 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
200.62
279
56033.166
... More
1.8 - Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.
63.49
497
31598.973
... More
2.1.3 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Including FormWork
34.64
6288
217831.908
... More
2.2.3 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including FormWork-FOOTINGS
23.94
6652
159268.032
... More
2.2.3 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including FormWork-PEDESTAL
7.9
6652
52557.12
... More
2.2.3 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including FormWork-PLINTH BEAM
6.64
6652
44174.592
... More
2.11 a - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.
3.46
93929
324997.281
... More
Sl No 1 a - Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for Cement Concrete Isolated Footing-8%
23.94
532
12741.3468
... More
Sl No 10 - Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for Cement Concrete Pedestal-10%"
7.9
665
5255.712
... More
Sl No 2 - Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for Cement Concrete Plinth Beam-50%"
6.64
3326
22087.296
... More
5.4 - Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)
1
6708
6708.45
... More
9.36 - Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications.
256.86
1732
445009.95
... More
9.32 - Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
5.55
2711
15046.605
... More
11.16.2 - Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
7181.81
154
1108871.464
... More
7.38 - Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer- in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
309.55
596
184615.62
... More
7.39.1 - Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :-Ridges plain (500 - 600mm)
33.4
473
15818.24
... More
7.39.6 - Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :-Gutter (600 mm over all girth)
71
1127
80066.7
... More
18.6 - Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in- Charge. For payment, only the actual area of glass on face 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item). Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10
to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
65.94
2079
137089.26
... More
8.4 - Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
309.55
120
37393.64
... More
1.1.1 - Mains Pipe Open Conduit System Supplying heavy gauge PVC conduit pipe . dia . mm thick
confirming to IS 2509 with suitable size bends, junction boxes,
adhesive paste etc , and fixing using inverted wood plugs in case of
RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy
gauge saddles at an interval of 700mm using NF screws. 1.1.1) 19/20 mm dia 2 mm thick Basic Rate -69=00 Wtg 5% - 3=45 Total - 72=45 PWD Ele SR 2023-24 Page No.1 Item code 1.1.1
215
72
15587.5
... More
2.2.2 - Points
Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase &
Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC
insulated copper wire (confirming to IS-694: and latest
amendments) without control switch shall be fixed on the existing
plastic sheet/ gang box, the other end of the wires shall be
terminated with sufficient loose length in a wood/PVC round block.
complete for each outlet.
2.2.2) Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch box
Basic Rate -379=00 Wtg 5% - 18=95 Total - 397=45 PWD Ele SR 2023-24 Page No.4 Item code 2.2.2 "
7
361
2527
... More
2.2.3 - Points
Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase &
Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC
insulated copper wire (confirming to IS-694: and latest
amendments) without control switch shall be fixed on the existing
plastic sheet/ gang box, the other end of the wires shall be
terminated with sufficient loose length in a wood/PVC round block.
complete for each outlet.
2.2.3) Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box
Basic Rate -555=00 Wtg 5% - 27=75 Total - 582=75 PWD Ele SR 2023-24 Page No.4 Item code 2.2.3 "
15
582
8742
... More
2.2.4 - Points
Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase &
Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC
insulated copper wire (confirming to IS-694: and latest
amendments) without control switch shall be fixed on the existing
plastic sheet/ gang box, the other end of the wires shall be
terminated with sufficient loose length in a wood/PVC round block.
complete for each outlet.
2.2.4) Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to out let via switches
Basic Rate -677=00 Wtg 5% - 33=85 Total - 710=85 PWD Ele SR 2023-24 Page No.4 Item code 2.2.4 "
18
710
12796.2
... More
2.3.2 - Wire:
Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS-
694:2010
2.3.2) 1.5 mm2
Basic Rate - 26=00 Wtg 5% - 1=30 Total - 27=30 PWD Ele SR 2023-24 Page No.4 Item code 2.3.2 "
110
27
3003
... More
2.3.2 - Wire:
Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS-
694:2010
2.3.3)2.5 mm2
Basic Rate - 42=00 Wtg 5% - 2=10 Total - 44=10 PWD Ele SR 2023-24 Page No.4 Item code 2.3.2 "
220
44
9702
... More
3.3.5 - Metal modular box:
Supplying and fixing surface/flush mounting unbreakable PVC
modular box suitable for mounting modular switch plates with due
groove cutting in Brick/C.C wall, including necessary rawl plugs,
Machine/NF screws etc., complete. 3.3.5) 8 Way
Basic Rate - 219=00 Wtg 5% - 10=95 Total - 229=95 PWD Ele SR 2023-24 Page No.7 Item code 3.3.5"
1
230
230
... More
3.3.7 - Metal modular box:
Supplying and fixing surface/flush mounting unbreakable PVC
modular box suitable for mounting modular switch plates with due
groove cutting in Brick/C.C wall, including necessary rawl plugs,
Machine/NF screws etc., complete. 3.3.7) 16 Way
Basic Rate - 294=00 Wtg 5% - 14=70 Total - 308=70 PWD Ele SR 2023-24 Page No.7 Item code 3.3.7"
6
308
1852.2
... More
3.5.5 - modular Switch Plate
Supplying and fixing superior quality modular switch mounting
polycarbonate plate with necessary supporting back plate with
required nos. of machine screws, bolts nuts etc., complete on the
existing metal/PVC box. 3.5.5) 8 Module
Basic Rate - 284=00 Wtg 5% - 14=20 Total - 298=20 PWD Ele SR 2023-24 Page No.7 Item code 3.5.5 "
1
298
298.2
... More
3.5.7 - modular Switch Plate
Supplying and fixing superior quality modular switch mounting
polycarbonate plate with necessary supporting back plate with
required nos. of machine screws, bolts nuts etc., complete on the
existing metal/PVC box. 3.5.7)16 Module
Basic Rate - 397=00 Wtg 5% - 19=85 Total - 416=85 PWD Ele SR 2023-24 Page No.7 Item code 3.5.7 "
6
416
2501.4
... More
3.6.1 - Modular switch
Supplying and fixing of modular switch & connected accessories on
existing modular switch plate as per IS 3854 and IS 1293. 3.6.1)6Amps one way.
Basic Rate - 102=00 Wtg 5% - 6=10 Total - 107=10 PWD Ele SR 2023-24 Page No.8 Item code 3.6.1"
47
107
5033.7
... More
3.6.2 - Modular socket
Supplying and fixing of modular switch & connected accessories on
existing modular switch plate as per IS 3854 and IS 1293. 3.6.2)6A Two Way Switch Basic Rate - 166=00 Wtg 5% - 8=30 Total - 174=30 PWD Ele SR 2023-24 Page No.8 Item code 3.6.2"
7
174
1220.1
... More
3.6.4 - Stepped Fan Regulator.
Supplying and fixing of modular switch & connected accessories on
existing modular switch plate as per IS 3854 and IS 1293. 3.6.4)Stepped Fan Regulator.
Basic Rate - 357=00 Wtg 5% - 17=85 Total - 374=85 PWD Ele SR 2023-24 Page No.8 Item code 3.6.4"
18
374
6748.2
... More
3.6.4 - Batten Holder
Supplying And fixing/replacing of 6/16/32A electrical
accessories on existing switch board. 3.14.7) 6A Batten Holder
Basic Rate - 74=00 Wtg 5% - 3=70 Total - 77=70 PWD Ele SR 2023-24 Page No.9 Item code 3.6.4"
58
77
4506.6
... More
11.3.2 - LED Tube Fitting
Supplying of .feet -PVC Batten with integrated LED tube . W
with high quality diffuser with Life of 25000 burning hours &
70% lumen maintenance with CRI 80. Power Input: 220-
240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2
years Warranty against any manufacturing defect working under
standard electrical condition.
11.3.2) LED light fighting 1 x4'- 20/22 w
Basic Rate - 724=00 Wtg 5% - 34=50 Total - 724=50 PWD Ele SR 2023-24 Page No.42 Item code 11.3.2"
36
724
26082
... More
11.6.2 - LED Square Fitting
Supplying of recess mounting non integral type . LED w
luminaire comprising of pressure decast/extruded aluminium
housing, with spring loaded false ceiling clamps, Power LEDs
with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per W,
120degree beam spread, life 25000 burning hours and
Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp
compartment is enclosed with anti glare opal diffuser which
enhances the lighting level LEDs are driven by HF electronic driver
integrated in a separate control gear assembly., with PF 0.95,
power loss should 5% of lamp Wage., short circuit & open circuit
protection to be integrated in the circuit, THD less than 20%, Life
as per LM 79. The operating input voltage should be between 130
to 275 V. BIS Approved and Tested by NABL/CPRI accredited
laboratory with 2 years Warranty against any manufacturing
defect working under standard electrical condition.
11.6.2) LED modular down light 1'x1' 24W
Basic Rate - 3692=00 Wtg 5% - 184=60 Total - 3876=60 PWD Ele SR 2023-24 Page No.43 Item code 11.6.2
3
3876
11629.8
... More
11.8.3 - Supply of LED Streetlight luminaire with pressure die cast
aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 130lm/w, nominal CRI 75.Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/
Lumileds/Osram make LED Source. 11.8.3) LED Streetlight 70 watts Basic Rate-5592.00,ASL 5%-279.60. Total-6871.60 PWD Ele SR 2023-24 Page No.46 Item code 11.8.3
1
6871
6871.6
... More
13.7.1 - LED Fitting fixing Charges
Fixing all types and all capacities of fluorescent /false ceiling / spot
light / CFL / LED fittings indoor on the wall/ ceiling / rafters /
girders using 23/0.0076"" twin twisted PVC insulated wires,
required Nos of round blocks and clamps. 13.7.1).On wall/ ceiling / Rafter / Girders
Basic Rate - 122=00 Wtg 5% - 6=10 Total - 128=10 PWD Ele SR 2023-24 Page No.55 Item code 13.7.1
"
39
128
4995.9
... More
6.3.1 - Fans 48”
Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single
phase AC supply conforming to ISS-374- 1979 and with double
ball bearing system. 6.3.1) 48"" Sweep (1200mm) Regular model Basic Rate - 2984=00 Wtg 5% - 149=20 Total - 3133=20 PWD Ele SR 2023-24 Page No.55 Item code 6.3.1"
16
3133
50131.2
... More
6.3.1 - Fan Fixing Charges Fixing a ceiling /wall mounting fan of all capacities and all types,
with necessary clamps and 'S' hook made out of 15mm dia MS rod,
with 5 A. ceiling rose of approved quality with necessary length of
23/0.0076 inch PVC insulated twin twisted wire of approved
quality, mounted on a suitable size wooden board and wired. Basic Rate - 315=00 Wtg 5% - 15=75 Total - 330=75 PWD Ele SR 2023-24 Page No.56 Item code 6.3.1"
16
330
5292.8
... More
6.5.1 - Extra length of GI pipe
Extra length of GI pipe of class B 19mm dia for down rod. Basic Rate - 197=00 Wtg 5% - 9=85 Total - 206=85 PWD Ele SR 2023-24 Page No.55 Item code 6.5.1"
16
206
3310.4
... More
5.6.4 - Wood Board
Supply and fixing polished wood board made of not less than
15mm thick plank on both sides of not more than 2 pieces and
fixing the same to the wall using tapered inverted wooden plugs
screws. . 5.6.4) 12"" x 12"" x 2""
Basic Rate - 181=00 Wtg 5% - 9=05 Total - 190=05 PWD Ele SR 2023-24 Page No.13 Item code 5.6.4"
7
190
1330.7
... More
5.7.2 - Fuse
Supplying & fixing of Porcelain fuse channel with cut out on
existing wooden/panel using necessary nuts, bolts and washers. 5.7.2) 32 A
Basic Rate - 241=00 Wtg 5% - 12=05 Total - 253=05 PWD Ele SR 2023-24 Page No.13 Item code 5.7.2"
1
107
107.1
... More
5.18.4 - MCB Switches.
Supplying & fixing miniature circuit breakers on existing MCB
distribution boards using necessary fixing materials and 'C' Type
curve, indicator ON/OFF, energy cross-3 with Short circuit
breaking capacity of 10K and complete wiring as required
confirming to IEC 60898.
5.18.4) 6-32 Amps DP Basic Rate - 739=00 Wtg 5% - 36=55 Total - 775=95 PWD Ele SR 2023-24 Page No.56 Item code 5.18.4"
2
776
1552
... More
5.18.5 - MCB Switches.
Supplying & fixing miniature circuit breakers on existing MCB
distribution boards using necessary fixing materials and 'C' Type
curve, indicator ON/OFF, energy cross-3 with Short circuit
breaking capacity of 10K and complete wiring as required
confirming to IEC 60898.
5.18.5) 40 A DP Basic Rate - 1060=00 Wtg 5% - 53=00 Total - 1113=00 PWD Ele SR 2023-24 Page No.56 Item code 5.18.5"
1
1113
1113
... More
5.19.8 - MCB distribution boards
Supplying and fixing regular MCB distribution boards on wall/ood
board / flush mounting using required clamps, bolts, nuts etc., with
provision for fixing suitable type capacity MCB's single phase/3
phase/single door with powder coated painting Made out of 14
SWG MS enclosure. I - Single Door 5.19.1) 4 Way SP & N
Basic Rate - 1241=00 Wtg 5% - 62=05 Total - 1303=05 PWD Ele SR 2023-24 Page No.56 Item code 5.19.8"
1
1303
1303.1
... More
1.2.3 - PVC Pipe Supplying heavy gauge PVC conduit pipe . mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 1.2.3) 32 mm dia 2.5 mm thick Basic Rate - 103=00 ASL 5% - 5=15 Total - 108=15 PWD Ele SR 2023-24 Page No.2 Item code1.2.3
30
108
3246
... More
25 a - Earthing 25.a) GI Grounding pipe, B - Class, 42 mm dia, 2.5 M long, 3.2 mm thick with bolts nuts, GI Strips and washers complete
25.a) Transformer grounding Basic Rate - 1729=00 ASL 5% - 86=45 Total - 1815=45 Hescom SR 2023-24 Item code 25.a (Material Cost) "
1
1815
1815.5
... More
25 a - Earthing 25.a) GI Grounding pipe, B - Class, 42 mm dia, 2.5 M long, 3.2 mm thick with bolts nuts, GI Strips and washers complete
25.a) Transformer grounding Basic Rate - 949=00 ASL 5% - 47=45 Total - 996=45 Hescom SR 2023-24 Item code 25.a (Labour Cost) "
1
996
996.5
... More
25 a - Digging of Pit 1.6 ) Digging of Pit for providing GI Pipe type Earthing
25.a) Transformer grounding Basic Rate - 759=00 ASL 5% - 37=95 Total - 796=95 Hescom SR 2023-24 Item code 25.a (Labour Cost) "
1
797
797
... More
32.05 - UG Cable 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975
32.04) 16 Sqmm, 2 Core, (9 GI Strips - 4 x 0.8 mm) Basic Rate - 88418=00 ASL 5% - 4420=90 Total - 92838=90 Hescom SR 2023-24 Item code 32.05 (Material Cost) "
0.04
148934
5957.38
... More
21.05 - UG Cable Labour Charges Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff
21.05) 2.5 to 25 Sqmm Basic Rate - 20886=00 ASL 5% - 1044=30 Total - 21930=30 ESCOMs SR 2023-24 Item code 21.05 (Labour Cost) "
0.04
21930
877.212
... More
1.6.1 - Digging Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. 1.6.1) In all kinds of soils. Depth upto 1.50m
Sl No Item No 1.6.1. PWD Civil SR vol 1 page no 6 Basic Rate - 484=00 ASL 5% - 24=20 Total - 508=20 Diamension-0.50 X 0.60 X 32m=9.6Cum"
9.6
508
4878.72
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements