Directorate Of Municipal Administration Tender

... More
The DMA has issued a formal invitation for competitive bids for the Directorate Of Municipal Administration project, for Electrification To Night Shelter House At Fort Ballari City in Ballari, Karnataka, with an estimated contract value of Rs. 4,64,333. The bid opening date for this tender is 10-06-2021 and the last date for bid submission is 24-06-2021. Interested bidders for Directorate Of Municipal Administration tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Directorate Of Municipal Administration - DMA Tender

Opening Date10 Jun 2021
Closing Date24 Jun 2021
Tender Amount₹ 4,64,333 
This is an estimated amount, exact amount may vary.
Notes
Download

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes.SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding.Electrical PWD Rates 2019-20 [P, No 52 Sl No8.3.1] 100 Liter capacity

1

-

28840

... More
g)16 Amps 3 pin top Electrical PWD Rates 2019-20 [P, No 11 Sl No, 3.14.12]

4

-

370.8

... More
d)6Amps Bakelite ceiling roseElectrical PWD Rates 2019-20 [P, No 11 Sl No, 3.14.5]

15

-

896.1

... More
Supplyinf of 1*4' PVC Battenwith integrated LED Tube 20/22 W with high quality diffuser with life of 25000 burning hours and 70% lume maintenance with CRI>80. power input 22-240V at 50/60Hz & Power factor >0.9 along with CE approved with 2 Years warranty against any manfactured defect working under standard Electircal Condtions.Electrical PWD Rates 2019-20 [P, No 64 Sl No, 12.3.3]

30

-

19312.5

... More
Supplying and fixing regular MCCB distribution Panel confirming to IS 8828, on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440Volts 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCCB/MCB's as outgoings confirming to IS8828. Electrical PWD Rates 2019-20 [P, No 27 Sl No,5.16.2, 16.3]

2

-

23484

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.Electrical PWD Rates 2019-20 [P, No 9 Sl No,3.5] 10 -12 Module Electrical PWD Rates 2019-20 [P, No 9 Sl No,3.5.5]

22

-

5211.8

... More
Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. GI Wire.Electrical PWD Rates 2019-20 [P, No 44 Sl No6.18.5] 10 SWG

50

-

3502

... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming .Electrical PWD Rates 2019-20 [P, No 05 Sl No2.,3] 2.5sqmm .Electrical PWD Rates 2019-20 [P, No 05 Sl No2.,3.3]

500

-

16480

... More
Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. Electrical PWD Rates 2019-20 [P, No 58 Sl No, 10.5.9]150 AH capacity

10

-

145230

... More
Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter..Electrical PWD Rates 2019-20 [P, No 29 Sl No,5.30]

1

-

1184.5

... More
c)6Amps lamp holder Electrical PWD Rates 2019-20 [P, No 11 Sl No, 3.14.6]

30

-

1792.2

... More
f)16Amps 3 way 5 pin socket Electrical PWD Rates 2019-20 [P, No 11 Sl No, 3.14.11]

4

-

432.6

... More
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. Electrical PWD Rates 2019-20 [P, No 27 Sl No, 5.17.1] 6-32Amps SP

15

-

6705.3

... More
Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT > 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire > IK08. Power Factor >0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency>130lm/w, nominal CRI >75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. Electrical PWD Rates 2019-20 [P, No 40 Sl No,12.8.5] LED Streetlight 120 Watts

5

-

47380

... More
Supplying and fixing /replacing of 6/16/32Amps electrical accessories on existing switch board .Electrical PWD Rates 2019-20 [P, No 11 Sl No, 3.14] a)6Amps SP switch Electrical PWD Rates 2019-20 [P, No 11 Sl No, 3.14.1]

100

-

4120

... More
1.5sqmm .Electrical PWD Rates 2019-20 [P, No 05 Sl No2.,3.4] for earthing

300

-

6336

... More
Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts,washers and check nuts etc., the pipe shall have 16 through holes of 12 mm diaElectrical PWD Rates 2019-20 [P, No 40 Sl No 6.1]

2

-

6179.38

... More
Open Conduit System Supplying heavy gauge PVC conduit pipe …….dia .......mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws..Electrical PWD Rates 2019-20 [P, No 02 Sl No 1.1] a) 19/20mm dia 2mm thick Electrical PWD Rates 2019-20 [P, No 02 Sl No 1.1.1]

50

-

2575

... More
b) 25mm dia 2mm thick Electrical PWD Rates 2019-20 [P, No 02 Sl No 1.1.2]

250

-

16737.5

... More
Supplying, and fixing of Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Electrical PWD Rates 2019-20 [P, No 16 Sl No, 4.7.1] Single Arm Bracket with 1000mm Standard 40/50MM dia

5

-

8698.35

... More
Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. Electrical PWD Rates 2019-20 [P, No 9 Sl No,3.3.]

22

-

3625.6

... More
c)Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box Electrical PWD Rates 2019-20 [P, No 5 Sl No, 2.2.3]

10

-

3862.5

... More
e)16Amps SP switch Electrical PWD Rates 2019-20 [P, No 11 Sl No, 3.14.9]

4

-

403.76

... More
h)Electronic stepped regulator Electrical PWD Rates 2019-20 [P, No 11 Sl No, 3.14.15]

15

-

3167.25

... More
06sqmm .Electrical PWD Rates 2019-20 [P, No 05 Sl No 2.3.5]

200

-

14420

... More
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet..Electrical PWD Rates 2019-20 [P, No 5 Sl No, 2.2] a)Short point upto 3Mtr from tapping point to out let via switch .Electrical PWD Rates 2019-20 [P, No 5 Sl No, 2.2.1]

25

-

4120

... More
b)Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch Electrical PWD Rates 2019-20 [P, No 5 Sl No, 2.2.2]

12

-

3090

... More
b)6Amps 3 way 5 pin socket Electrical PWD Rates 2019-20 [P, No 11 Sl No, 3.14.3]

50

-

3090



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.