Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Directorate Of Municipal Administration - DMA Tender

Works
Electrical and Electronics
Electrical Works
Opening Date25 Oct 2024
Closing Date11 Nov 2024
Tender Amount₹ 40,39,450.43 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code32.14 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LT UG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 --- 95 Sqmm, 3.5 Core, (21 GI Strips - 4 x 0.8 mm) ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

0.3

391875

117562.725

... More
code21.05 - Laying of LT UG cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff -- 2.5 to 25 Sqmm ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

0.13

21930

2850.939

... More
code21.06 - Laying of LT UG cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff -- 35 to 95 Sqmm ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

0.3

32695

9808.785

... More
code60.01 - Aluminium End Terminal (Lug) - 10 Sqmm ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

12

2

25.2

... More
code60.03 - Aluminium End Terminal (Lug) - 25 Sqmm ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

24

3

75.6

... More
code60.07 - Aluminium End Terminal (Lug) - 95 Sqmm ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

32

15

504

... More
code63.01 - Brass Cable Gland - 25 mm ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

8

82

663.6

... More
code63.04 - Brass Cable Gland - 45 mm ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

2

206

413.7

... More
code66.05 - Optical Fibre Cable (OFC) and its Accessories - HDPE/PLB Pipe 40/33 mm ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

0.12

65452

7854.336

... More
code68.17 - Caution/Danger Board ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

4

157

630

... More
code5.15 - Labour charges for Fixing Danger Board ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

4

84

336

... More
code3 - Providing M-Sand : Supplying and filling in plinth, foundations / UG cable work with approved M-sand including watering, ramming, consolidating and dressing. The rate includes the cost of material, labour charges, required tools and plants etc., complete. Work shall be carried out as per the instructions of Engineer- in-charge of works as per the standard procedure. ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

30

2063

61897.5

... More
code10.1.6 - Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtr at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at rated load made on special purpose CNC machines for consistency in quality and workmanship, Powder coated for long lasting service life and superior finish, With UV resistant powder coating, can withstand extreme environment, Use of special hardware for longer life, Insulation material meets exacting IS 8183 specifications for better sound attenuation, Flush styling - no projections, Fluid drains for lube oil and fuel, Fuel filling point inside the enclosure. The complete set shall have sufficient safety and adhere to NEC, NBC 2016, IEC, CPWD specifications, PCB norms and KSGEI Acts and Rules. -- 50kVA /40 kw ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

1

648236

648236.4

... More
code10.2.2 - Supply, Erection, testing and commissioning of AMF panel suitable for 40-50 KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .....amps 4 pole contactor for alternator with thermal O/L relay,..... Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, ....capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and Flat/Boost facility. The complete set shall have sufficient safety and adhere to NEC, NBC 2016, IEC, CPWD specifications, PCB norms and KSGEI Acts and Rules ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

1

74986

74986.8

... More
code11.8.3 - Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 70 Watt System Power consumption. LED Efficiencygreater than1301m/w, nominal CRI greater than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree /Nichia /Lumileds /Osram make LED Source. ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

14

6291

88082.4

... More
code13.6 - Fixing charges of post top/Gate/Garden fitting/LED on the existing CI/GI or any other pipe using required size of reducer, wiring using suitable wires. ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

14

207

2910.6

... More
code13.1.2 - Supplying and Fixing of 32 mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

14

1097

15361.5

... More
code12.56 - Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit. The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia(Item no 12.56) ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

6

3685

22113

... More
code12.57 - Supplying, fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

8

4468

35750.4

... More
code12.58.1 - Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

85

86

7318.5

... More
code12.58.7 - Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm Copper strip ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

15

598

8977.5

... More
code5.1 - Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 volts 1/3 phase motor upto 5 HP. ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

1

2023

2023.35

... More
code5.7.1 - Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 16 Amps ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

3

164

494.55

... More
code5.7.3 - Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 63 Amps ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

3

421

1263.15

... More
code5.42.1 - Fabricating supplying and mounting MS box made out 14 SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

180000

-

93600

... More
code1.1.2 - Open Conduit System - Supplying heavy gauge PVC conduit pipe 25 mm dia, 2 mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.(Item no 1.1.2) ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

500

85

42525

... More
code1.3.2 - Supplying heavy gauge PVC Conduit Pipe 24 mm dia, 2 mm thick with suitable size bends, metal junction boxes adhesive paste etc.,by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

1300

82

107835

... More
code1.5.2 - Supplying and fixing PVC/metal conduit Deep junction box -- 25 mm deep Junction box ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

20

58

1176

... More
code1.7.2 - Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. - upto 50 mm conduit CC floor ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

500

72

36225

... More
code1.11 - Supplying And Fixing "S" Hook made out of 14 mm dia M.S.Rod. ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

50

54

2730

... More
code2.3.1 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010. -- 1 sqmm ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

3500

19

69825

... More
code2.3.2 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010. -- 1.5 sqmm ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

9200

27

251160

... More
code2.3.3 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010. -- 2.5 sqmm ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

5000

44

220500

... More
code2.3.4 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010. -- 4 sqmm ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

2500

66

165375

... More
code2.3.5 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010. -- 6 sqmm ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

1800

96

173880

... More
code2.6.2 - Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to 13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 - 3C x 2.5 Sq mm ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

50

122

6142.5

... More
code3.3.6 - Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. -- 10-12 Way ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

5

274

1370.25

... More
code3.4.4 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall -- 6 Way ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

10

231

2310

... More
code3.4.5 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall -- 8 Way ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

10

274

2740.5

... More
code3.4.6 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall -- 10-12Way ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

80

334

26796

... More
code3.5.4 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. -- 6 Module ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

10

245

2457

... More
code3.5.5 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. -- 8 Module ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

10

298

2982

... More
code3.5.6 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. -- 10 -12 Module ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

80

361

28896

... More
code3.6.1 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. -- 6Amps one way Switch ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

360

107

38556

... More
code3.6.2 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. -- 6Amps two way Switch ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

4

174

697.2

... More
code3.6.3 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. -- 6Amps Three way socket ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

170

179

30523.5

... More
code3.6.4 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. -- Stepped Fan Regulator Two module ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

50

374

18742.5

... More
code3.6.7 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. -- 16A One Way Switch. ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

85

189

16065

... More
code3.6.9 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. -- 32A DP Switch. ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

10

342

3423

... More
code3.6.10 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. -- 6/16Amps universal socket. ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

85

247

21063

... More
code3.14.5 - Supplying and fixing/replacing of 6/16/32A electrical accessories on existing switch board. -- 6A Bakelite Ceiling Rose ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

70

81

5733

... More
code3.14.7 - Supplying and fixing/replacing of 6/16/32A electrical accessories on existing switch board. -- 6A Batten Holder ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

90

77

6993

... More
code5.14.1 - Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. -- 22/25 Amps ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

1

2320

2320.5

... More
code5.15.9 - Supplying and fixing Moulded Case Circuit Breaker(MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with adjustable thermal magnetic release, Microprocessor release shall have Earth Fault as per IS/IEC60947-2.(Icu=100%lcs). In 4P MCCB, all Poles should have protection for Short-Circuit/OverLoad. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation(insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open).Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. -- FOUR POLE -- 100Amps 25kA ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

2

8911

17822.7

... More
code5.16 - Supplying and fixing of Shunt trip suitable for MCCB.CBCT. ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

2

1788

3576.3

... More
code5.18.4 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. -- 6-32Amps DP ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

15

775

11639.25

... More
code5.18.7 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. -- 6-32Amps TPN ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

15

1802

27042.75

... More
code5.19.4 - Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. I - Single Door - 12 Way SP & N ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

1

1956

1956.15

... More
code5.19.5 - Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. I - Single Door - 16 Way SP & N ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

5

3078

15393

... More
code5.20.1 - Supplying, fixing and wiring Residual current circuit breaker(RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. -- 16A-25A 2 pole ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

5

4490

22454.25

... More
code5.33 - Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy. ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

1

9780

9780.75

... More
code5.34 - Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound. ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

3

590

1770.3

... More
code5.35 - Supplying, fixing and wiring Electronic Trivector Meter(ETV) 5 to 32/63 A three phase 4 wire whole current class-1 Accuracy Energy Meter. ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

1

5990

5990.25

... More
code5.36 - Supplying, fixing and wiring 1000/5A to 1600/5A 15VA Burden class 1 Current Transformer ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

4

882

3528

... More
code5.38 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C. ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

9

540

4866.75

... More
code5.40.1 - Supplying 100 amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. -- 4x30x6mm Aluminium Strips ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

15

2588

38823.75

... More
code5.41.1 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. -- 40x40x6mm ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

15

320

4803.75

... More
code5.47 - Supplying and fixing Microprocessor based Electronic timer (without contactor, Din Mounting using necessary bolts, nuts and washers etc.,.) 3-120sec setting ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

1

2430

2430.75

... More
code5.51.1 - Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,.Adjustable Time Delay(0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 Volts - 125 A ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

1

77527

77527.8

... More
code6.1 - Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

20

1566

31332

... More
code13.14 - Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5A ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

20

516

10332

... More
code6.4.1 - Supplying of Ceiling Fan with Capacitor rating As per guide line of BEE5 star rating and IS:374/19 and also comply with IS:1709/1984 with latest amendment, Rated voltage 220V/50Hz, Rated power upto 35W +/-10%, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/-10% RPM, Rated air delivery 210 +/-10% Cubic Meter Minimum, Rated service value 6.2 CMM/W,Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg Cover and ambient of 400 C by resistance method at 245V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W & current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2 year manufacturer Warranty.(BLDC fans) -- 48" Sweep 5 Star (1200 mm) ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

50

2810

140542.5

... More
code13.1 - Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

50

179

8977.5

... More
code6.8.5 - Supplying of 5 Star rated 1.5 Ton Capacity TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50Hz 230V with hermetically sealed inverter compressor with air cooled condenser, latest R410A/R-32 refrigerant fan motor, start & run capacitors, relay & overload protector internal unit, with one indoor & one outdoor unit. The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube suitable capacity 3 core sheathed/PVC copper cable and a battery operated wireless remote unit. ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

2

59172

118345.5

... More
code6.12 - Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C. ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

2

3333

6667.5

... More
code6.13.1 - Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oiland gas charging for additional piping length of tube. -- Split ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

20

1626

32529

... More
code9.1.1 - Supplying, erecting, testing and commissioning of voltage stabilizer suitable for 170 to 270 v input and load variation from no load to full load, with overload protection, spike suppression, operating at 00C to 400 C. Range etc., complete ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

2

4194

8389.5

... More
code8.1 - Supplying and drawing UTP-CAT 6E LAN cable. ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

3500

39

139650

... More
code8.4.2 - Supplying & Fixing of switch mounting rack with power manager & Cable manager. -- 6U with 450mm depth ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

3

7325

21977.55

... More
code8.4.4 - Supplying & Fixing of switch mounting rack with power manager & Cable manager. -- 12U with 450mm depth ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

4

9276

37107

... More
code8.9.5 - Supplying & fixing of Network Switches -- 24 port 10/100 Switch ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

7

4935

34545

... More
code8.10.1 - Supplying & fixing of I/O socket with back box - Single I/O ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

40

514

20580

... More
code11.3.2 - Supplying of 4 feet - PVC Batten with integrated LED tube 20/22W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

70

724

50715

... More
code11.5.3 - Supply of round/square recess/surface mounted rolling type LED Down light with 15-18 Watt GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @50/60Hz & Power factor greater than0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition -- LED square or round down light ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

25

1390

34755

... More
code11.6.3 - Supplying of recess mounting non integral type 36 Watt LED luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRIgreater than70%, efficacygreater than100 lumen per W, 120 degree beam spread, lifegreater than25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM80. The lamp compartment is enclosed with antiglare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PFgreater than0.95, power loss should lesser than 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM79. The operating input voltage should be between 130 to 275V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2years Warranty against any manufacturing defect working under standard electrical condition. -- LED modular down light 2'x2' ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

45

4780

215129.25

... More
code11.11.4 - Supplying & fixing of retrofit type-LED bulb 9W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degreeK, CRIgreater than70%. efficacygreater than80 lumen per W,lifegreater than25000 burning hours and Compliance to IS 10322/IEC 60598, LM79 & LM80.The LED are driven by HF electronic driver integrated in the system,with PFgreater than0.95,power loss shouldlesser than5% of lamp Wage.,short circuit & open circuit protection to be integrated in the circuit,THD less than 20%,Life as per LM79.The operating input voltage should be between 130 to 275V.BIS Approved and Tested by NABL/CPRI accredited laboratory with 2years Warranty against any manufacturing defect working under standard electrical condition. ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

20

161

3234

... More
code13.7.1 - Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps -- On wall / ceiling / Rafter / Girders ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

160

128

20496

... More
code15.6 - Providing ABC Powder based MAP 90, 2Kg -- Supply & Installation of 2 kg Fire Extinguisher Mono Ammonium Phosphate Powder 90, Stored Pressure Type, Pressure Gauge, Gross Weight 3.6 Kg, empty weight 1.6 Kg, Can Height 344MM, Diameter 108MM, Discharge Time less than 8 Secs, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 2 meters, applicable on Class A,B,C and electrically started Fire, A Rating 1A, B Rating 8B, Can construction : Deep drawn & Co., Mig welded, valve Construciton : Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy Polyster power coating, Sheet metal thickness: 1.60MM, 5 years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., complete including cost of materials, labour, usage charges of machinery complete as per specifications. complete IS 15683, CE Approved ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

4

1942

7770

... More
code11.58 - Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineerin-charge. (Made of G.I. wire of dia 4 mm) ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

30

843

25294.5

... More
code1.14.1 - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work -- In all kinds of soils Depth upto 3 m ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

170

107

18207

... More
code9.6.4 - Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete etc. complete. NOTE: Upto 110mm dia Coil shall be used. -- HDPE Grade PE80-PN 3.0, 110mm dia ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

290

321

93177

... More
code11.1.9 - Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete.-- Light Duty GI pipe of 100mm Dia ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

10

1111

11119.5

... More
code2.1.1 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. -- Mix 1:5:10 Using 40 mm nominal size graded crushed coarse aggregates ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

2

5604

11209.8

... More
code2.2.1 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications -- M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

16

6601

105621.6

... More
code2.11.h - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.All other type of structures ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

0.12

82961

9955.386

... More
code8.1 - Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

50

221

11077.5

... More
code7.38 - Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

20

596

11928

... More
code11.16.1 - Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORK

270

142

38556



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.