Directorate Of Municipal Administration Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Directorate Of Municipal Administration - DMA Tender

Works
Civil And Construction
Opening Date26 Dec 2024
Closing Date8 Jan 2025
Tender Amount₹ 40,00,000.01 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. PWD CSR Vol-1 2023-24 P.No.15, I.No.2.2.3 (Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding on finished rate of concrete per m3 Page 111 Sl no. 1.a)

9.0365

7185

64927.43323

... More
code05 - Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. PWD CSR Vol-1 2023-24 P.No.16, I.No.2.3.2 (Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding on finished rate of concrete per m3 Page 111 Sl no. 9)

1.94

11566

22439.592

... More
code06 - Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. PWD CSR Vol-1 2023-24 P.No.16, I.No.2.3.2 (Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding on finished rate of concrete per m3 Page 111 Sl no. 1.a)

40.7

7348

299076.624

... More
code07 - Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. PWD CSR Vol-1 2023-24 P.No.16, I.No.2.3.2 (Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding on finished rate of concrete per m3 Page 111 Sl no. 1.a)

5.98

10206

61031.88

... More
code08 - Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) PWD CSR Vol-I1 2023-24 P.No.09, I.No.5.4

17.435

6708

116961.82575

... More
code09 - Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. PWD CSR Vol-1 2023-24 P.No.07, I.No.1.8

183.14

497

91148.778

... More
code10 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. PWD CSR Vol-I1 2023-24 P.No.17, I.No.6.33

106.06

1292

137087.853

... More
code11 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. PWD CSR Vol-II 2023-24 P.No.41, I.No.8.2.1

225.61

309

69882.6975

... More
code12 - Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinerycomplete as per specifications and as per directions of the Engineer-in-Charge. PWD CSR Vol-1 2023-24 P.No.77, I.No.11.2

8380

118

994287

... More
code13 - Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin- charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.. PWD CSR Vol-II 2023-24 P.No.26, I.No.7.38

590.77

596

352335.228

... More
code14 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. PWD CSR Vol-II 2023-24 P.No.50, I.No.8.51

225.61

105

23689.05

... More
code15 - Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.PWD CSR Vol-II 2023-24 P.No.50, I.No.8.54.1

225.61

76

17293.0065

... More
code16 - Finishing walls with Premium Acrylic Smooth exterior paint of required shade : Old work (one coats applied @ 0.83 l/10 m²) including preparing the surface after thoroughly cleaning the surface to remove all dirt,dust and foreign matter , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. PWD CSR Vol-II 2023-24 P.No.53, I.No.8.75.2

225.61

76

17293.0065

... More
code17 - Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. PWD CSR Vol-II 2023-24 P.No.78, I.No.11.6.1

22.5

2764

62204.625

... More
code18 - Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. PWD CSR Vol-II 2023-24 P.No.79, I.No.11.8.4

2

25920

51840.6

... More
code19 - Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately):For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications. PWD CSR Vol-II 2023-24 P.No.87, I.No.11.35.1.1

240

474

113904

... More
code20 - Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. PWD CSR Vol-II 2023-24 P.No.87, I.No.11.35.1.1

122.36

145

17858.442

... More
code21 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Overload and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947-2. (Icu=100%lcs).In 4P MCCB,all Poles should have protection for Short-Cicrcuit/OverLoad.For Microprocessor MCCB S Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open).Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. Three Pole- 100 A 25 kA (P.No.17, I.No.5.15.1 in CSR Electrical SR Volume-6 2023-24) (P.No.17, I.No.5.15.1 in CSR Electrical SR Volume-6 2023-24)

2

6390

12780.6

... More
code22 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Overload and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947-2. (Icu=100%lcs).In 4P MCCB,all Poles should have protection for Short-Cicrcuit/OverLoad.For Microprocessor MCCB S Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open).Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. Four Pole-100 A 25 kA (P.No.17, I.No.5.15.9 in CSR Electrical SR Volume-6 2023-24)

1

8911

8911.35

... More
code23 - Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA.(P.No.21, I.No.5.46.1 & 5.46.6 in CSR Electrical SR Volume-6 2023-24)

6

220

1323

... More
code24 - 16-32 A SP (P.No.21, I.No.5.46.1 in CSR Electrical SR Volume-6 2023-24) 63 A TP (P.No.21, I.No. 5.46.6 in CSR Electrical SR Volume-6 2023-24)

6

1254

7528.5

... More
code25 - Supplying A rated 3 phase with neutral busbar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve,mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board.The busbar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.(P.No.20, I.No.5.40.1 in CSR Electrical SR Volume-6 2023-24) 100 A 4 x 30 x 6 mm Aluminium Strips

6

2588

15529.5

... More
code26 - Supplying and fixing angle iron frame work fabricated out of M.S.angle iron.and M.S.Flat 40 x 40 x 6 mmwith bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint.(P.No.20, I.No.5.41.1 in CSR Electrical SR Volume-6 2023-24)

6

320

1921.5

... More
code27 - Fabricating supplying and mounting MS box made out14 SWG suitable for floor/wall mounting,fully weather proof with provision for better heat dissipation,provided with hinged front cover,equipped with tamper proof locking arrangements,with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7 tanks treatment with powder coated paint and finally finished with approved colour etc., complete.(P.No.20, I.No.5.42.1 in CSR Electrical SR Volume-6 2023-24)

28000

-

14840

... More
code28 - Supply and fixing of 3pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts,nuts,washers and wiring etc., complete with AC-3 Rating and as per IS-13947.(P.No.15 , I.No.5.13.1 in CSR Electrical SR Volume-6 2023-24) 25 A

5

1354

6772.5

... More
code29 - Supplying and fixing Micro processor Based Astro nomical timer Switch with using necessary bolts, nuts and washers.(P.No.21, I.No.5.48 in CSR Electrical SR Volume-6 2023-24)

3

5085

15255.45

... More
code30 - Supply and fixing of Auxiliary contactor relay with 2 NO and 2 NC contact and operating coil voltage of 220V to 260V. fixed on existing wood/panel board using necessary bolts, nuts, washers and wiring etc.(P.No.22, I.No.5.53 in CSR Electrical SR Volume-6 2023-24)

3

1396

4189.5

... More
code31 - Supplying and fixing of metal clad industrial plugs and sockets. (P.No.9, I.No.3.13.3 in CSR Electrical SR Volume-6 2023-24) 3pole+ earth 440V PLUG-32 Amps. 16 Amps (P.No.9, I.No.3.13.3 in CSR Electrical SR Volume-6 2023-24)

2

474

949.48

... More
code32 - Supplying and fixing of metal clad industrial plugs and sockets. (P.No.9, I.No.3.13.3 in CSR Electrical SR Volume-6 2023-24) 3pole+ earth 440V PLUG-32 Amps. 32 Amps (P.No.9, I.No.3.13.4 in CSR Electrical SR Volume-6 2023-24)

2

640

1280.7

... More
code33 - Supplying,fixing and wiring 0to30 A Direct Reading AC analog type Ammeter.(P.No.18, I.No.5.24 in CSR Electrical SR Volume-6 2023-24)

4

488

1953

... More
code34 - Supplying,fixing and wiring 0 to 600 V 96x96mm AC Voltmeter on existing panel/wood board.(P.No.18, I.No.5.22 in CSR Electrical SR Volume-6 2023-24)

1

474

474.6

... More
code35 - Supplying,fixing and wiring rotary selector switch suitable for Ammeter.(P.No.19, I.No.5.27 in CSR Electrical SR Volume-6 2023-24)

4

210

840

... More
code36 - Supplying, fixing and wiring rotary selector switch suitable for Voltmeter.(P.No.19, I.No.5.28 in CSR Electrical SR Volume-6 2023-24)

1

168

168

... More
code37 - Supplying,fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound.(P.No.19, I.No.5.34 in CSR Electrical SR Volume-6 2023-24)

4

590

2360.4

... More
code38 - Supplying and fixing digital frequency meter with latest micro controller technology,ultra bright 4digit LED display,from 30-500VAC and optional or relay output for high/low frequency and wiringcomplete.(P.No.19, I.No.5.32 in CSR Electrical SR Volume-6 2023-24)

1

1023

1023.75

... More
code39 - Supplying,fixing and wiring heavy duty low voltage capacitors conforming to IS2834.3 phase,400/440V grade,for power factor improvement of rotating machineries like induction motor.(P.No.19, I.No.5.37 in CSR Electrical SR Volume-6 2023-24)

5

504

2520

... More
code40 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. ESCOM SR 2023-24 I No. 32.11 Pg.13

0.03

187921

5637.6495

... More
code41 - 3.5Cx50 Sqmm Al Ar cable ESCOM SR 2023-24 I No. 32.11 Pg.13

0.02

188836

3776.724

... More
code42 - 4Cx25 Sqmm Al Ar cable.ESCOM SR 2023-24 I No. 32.08 Pg.13

0.02

148934

2978.684

... More
code43 - 4Cx16 Sqmm Al Ar cable ESCOM SR 2023-24 I No. 32.05 Pg.13

0.02

123904

2478.084

... More
code44 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. LT cable. 2.5 to 25 sqmm ESCOM SR 2023-24 I No. 21.05 Pg.52

0.06

21930

1315.818

... More
code45 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. LT cable. 35 to 95 Sqmm .ESCOM SR 2023-24 I No. 21.06 Pg.52

0.03

32695

980.8785

... More
code46 - Earth Work Excavation for pipeline/cables by manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shorting, strutting,barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a redius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth sides of foundations etc.. in layers not exceeding 20 cm in depth, consolidated each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.(P.No.06, I.No 1.6.1 in KPWD CSR volume-1, 2023-24. In all kind of soils, Depth upto 1.50m

4.5

508

2286.9

... More
code47 - Cable Joint and wiring (for HT & LT UG Cable). LT UG Cable. Heat shrinkable Type Terminations ESCOM SR 2023-24 I No. 22.13 Pg.53. 35 to 95 Sqmm .ESCOM SR 2023-24 I No. 22.14 Pg.53

2

199

399

... More
code48 - Cable Joint and wiring (for HT & LT UG Cable). LT UG Cable. Heat shrinkable Type Terminations ESCOM SR 2023-24 I No. 22.13 Pg.53. . 35 to 95 Sqmm .ESCOM SR 2023-24 I No. 22.14 Pg.53

12

98

1184.4

... More
code49 - Supplying & Fixing heavy guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws. 19/20mm dia PVC 2mm thick conduit.. PWD Electrical SR-2023-24, ITEM NO:1.1 ,CH-1, PAGE NO-2

25

72

1811.25

... More
code50 - Supplying & Fixing heavy guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws. 25mm dia PVC 2mm thick conduit.PWD Electrical SR-2023-24, ITEM NO:1.1.2 ,CH-1, PAGE NO-2

25

85

2126.25

... More
code51 - Supplying & Fixing heavy guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws.. 32mm dia PVC 2.5mm thick conduit.PWD Electrical SR-2023-24, ITEM NO:1.1.3 ,CH-1, PAGE NO-2

20

111

2226

... More
code52 - Supplying & Fixing heavy guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws.. . 40mm dia PVC 2.5mm thick conduit.PWD Electrical SR-2023-24, ITEM NO:1.1.4 ,CH-1, PAGE NO-2

20

156

3129

... More
code53 - Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5 Sqmm (Phase&Neutral) & 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gangbox, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch. PWD Electrical SR-2023-24, ITEM NO:2.1.1 ,CH-1, PAGE NO-5

10

299

2992.5

... More
code54 - Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5 Sqmm (Phase&Neutral) & 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gangbox, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. . Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch .PWD Electrical SR-2023-24, ITEM NO:2.1.2 ,CH-1, PAGE NO-5

10

413

4137

... More
code55 - Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5 Sqmm (Phase&Neutral) & 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gangbox, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch.PWD Electrical SR-2023-24, ITEM NO:2.1.3 ,CH-1, PAGE NO-5

6

598

3591

... More
code56 - Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5 Sqmm (Phase&Neutral) & 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gangbox, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to outlet via switches.PWD Electrical SR-2023-24, ITEM NO:2.1.4 ,CH-1, PAGE NO-5

5

743

3717

... More
code57 - Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5 Sqmm (Phase&Neutral) & 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gangbox, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.. Three outlet in a row, above 6Mts upto 10Mtr from tapping point to out let via switches.PWD Electrical SR-2023-24, ITEM NO:2.1.5 ,CH-1, PAGE NO-5

4

1086

4347

... More
code58 - Wiring for lighting /power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010. 1.0 Sqmm Cu FRLS wire. PWD Electrical SR-2023-24, ITEM NO:2.3.1 ,CH-1, PAGE NO-5

180

19

3591

... More
code59 - Wiring for lighting /power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010.. 1.5 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.2 ,CH-1, PAGE NO-5

80

27

2184

... More
code60 - Wiring for lighting /power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010. 2.5 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.3 ,CH-1, PAGE NO-5

120

44

5292

... More
code61 - Wiring for lighting /power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010. 4.0 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.4 ,CH-1, PAGE NO-5

60

66

3969

... More
code62 - Wiring for lighting /power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010. 6.0 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.5 ,CH-1, PAGE NO-5

40

96

3864

... More
code63 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos.of machine screws, bolts nuts etc.,complete on the existing metal/PVC box. 10 - 12 Module Polycarbonate switch box plate. PWD Electrical SR-2023-24, ITEM NO:3.5.6 ,CH-3, PAGE NO-8

5

361

1806

... More
code64 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos.of machine screws, bolts nuts etc.,complete on the existing metal/PVC box. 10 - 12 Module Polycarbonate switch box plate. 3 Module Polycarbonate switch box plate.PWD Electrical SR-2023-24, ITEM NO:3.5.2 ,CH-3, PAGE NO-5

4

169

676.2

... More
code65 - Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cuttingin Brick/C.C wall, including necessary rawl plugs,Machine/NF screws etc., complete. 3 Way PWD Electrical SR-2023-24, ITEM NO:3.3.2 ,CH-3, PAGE NO-8

5

130

651

... More
code66 - Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cuttingin Brick/C.C wall, including necessary rawl plugs,Machine/NF screws etc., complete.. 10-12 Way PWD Electrical SR-2023-24, ITEM NO:3.3.6 ,CH-3, PAGE NO-8

5

274

1370.25

... More
code67 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Switches & sockets outlets in Existing modular box. 6A one way switch.PWD Electrical SR-2023-24, ITEM NO:3.6.1 ,CH-3, PAGE NO-9

4

107

428.4

... More
code68 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Switches & sockets outlets in Existing modular box. 6A 3 way socket.PWD Electrical SR-2023-24, ITEM NO:3.6.3 ,CH-3, PAGE NO-9

4

179

718.2

... More
code69 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Switches & sockets outlets in Existing modular box.6/16A Universal socket.PWD Electrical SR-2023-24, ITEM NO:3.6.10 ,CH-3, PAGE NO-9

2

247

495.6

... More
code70 - Supply of LEDStreetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising ofanti glare clear diffuserwith Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @Lumen Maintenanceof70 , maximum lightintensityshouldbebetween 60degrees to 70degrees. CCT 5500K, IP66optical andelectrical compartment &impact resistanceof complete luminaire IK08. Power Factor 0.9 withmains,SurgeProtection-Min5KValongwithOver voltage/Overload, short circuit/miss-wiring protection. Compatible for pole mounting with outer dia of 40 mm to 50mm.Universal Voltagedriver tooperatewidevoltage range from100Vto 270V 50 60Hz application. Compliance to IS 10322 IEC60598 LM79 LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site locationwith minimized minimal tools. LED Light fixture with .WSystem Power consumption. LED Efficiency 1301m w, nominal CRI 75. Luminaire manufacturer should have in-house facilityaccredited by NABL/CPRI any Government certified agency & Design & Development facility certified by ISO9001:2008. Housingwith supplierwordmark/name shallbe Engraved /Embossing on thediecast housing/Bodypart. Warranty of 2Years against any manufactur indefec two rkin gunder standard electrical conditionsas mentioned above should be given by LEDmanufacturer Cree Nichia Lumileds Osram make LED Source CSR Electrical SR-2023-24 ITEM NO11.8.2, PAGE NO-46 40 LED Source. LED flood light 100W

10

9960

99603

... More
code71 - GI/Copper strips for grounding connections, using necessary fixing materials as required.25x3mm GI Strip.PWD Electrical SR-2023-24, ITEM NO:12.58.2 ,CH-12, PAGE NO-54

82

44

3616.2

... More
code72 - 2 mm thick perforated cable GI tray with one xisting MS angle support using necessary GI bolts/nuts and washer or welding as required.(PWD Electrical SR-2023-24, ITEM NO:12.59.2 ,CH-12, PAGE NO-55 300x50mm

6

616

3698.1

... More
code73 - Supplying, fixing, wiring, earth electrode for grounding conduits, I.C.cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5m long buried in a pit.The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth.The connection from the pipe to the conduit etc.,is to be established through GIwire of size asper lSI specification 7.3.3.of IS 732 using 12mm dia bolts,nuts,washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.PWD Electrical SR-2023-24, ITEM NO:12.56,CH-12, PAGE NO-54

1

3685

3685.5



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.